Presented by: Danny Hintzman Luminant Power Company. Fall User Group 2015
|
|
- Juliana Atkinson
- 6 years ago
- Views:
Transcription
1 Presented by: Danny Hintzman Luminant Power Company Fall User Group 2015
2
3 A good overall tool for determining what is recertification and what is Diagnostic: Recertification, Diagnostic, and Maintenance charts Located in Section 12 of the Emissions Monitoring Policy Manual manual.pdf
4 From Part 75 Emissions Monitoring Policy Manual-2013
5 From Part 75 Emissions Monitoring Policy Manual-2013
6 From Part 75 Emissions Monitoring Policy Manual May 2013 (Continued)
7 Examples of changes which require recertification include: Replacement of the analyzer; Change in location or orientation of the sampling probe or site; Complete replacement of an existing continuous emission monitoring system or continuous opacity monitoring system; The owner or operator shall also recertify the continuous emission monitoring systems for a unit that has recommenced commercial operation following a period of long-term cold storage as defined in How do you know when an event is Recertification or Diagnostic???
8 Important Column for differentiating between Recertification and Diagnostic Events.
9
10
11
12
13 More examples of RDM charts for other system types are in Section 12 of the Emissions Monitoring Policy Manual
14 Step 1. Notify State and EPA Regional Office of recertification event (IAW 75.61). 3 Types of Events: Full recertification at least 21 days prior to 1 st scheduled day of important testing; Emergency recertification within 2 business days after 1 st scheduled day of testing; Partial recertification at least 7 days prior to 1 st scheduled day of testing.
15 Step 2. Perform recertification events (as referenced in 75.20). Important to Note: A. End of Probationary Calibration Error test - begins valid quality assured data and recertification process. B. Linearity and/or Cycle Time test - within 168 consecutive unit operating hours after the Probationary Calibration test (if necessary). C. 7-Day Calibration Error test - within 21 consecutive unit operating days after the Probationary Calibration test. D. RATA - within 720 consecutive unit operating hours after the Probationary Calibration test.
16 See 40 CFR Part for more details on specific tests that are required for each type of monitoring system. Note: Failing or aborting due to a problem with CEMS during any recertification event, starts the recertification period over, i.e. - the CEMS must not repaired, re-linearized or reprogrammed (e.g., changing flow monitor polynomial coefficients, linearity constants, or K-factors).
17 Step 3. Make Monitoring Plan changes for Component/System/DAHS Replacements. Reference: 75.53(g)(1)(iii)(A) and (B) Whenever a new analyzer is brought into service at a monitoring location, it must be assigned a new unique component ID. If an existing analyzer is removed and is later returned to service at the same monitoring location, the original component ID should continue to be used.
18 System ID's do not need to be changed unless there is going to be overlap where the existing system will continue to be used to monitor and report data while a new system of monitoring components is being certified. For minor DAHS upgrades (such as vendor patches) it is not necessary to change any monitoring system or component IDs. For DAHS vendor or platform changes you must close out the old DAHS component by adding an End date and hour to the existing records linking the old DAHS component to each monitoring system and then create a new record for each system pointing to the new DAHS component.
19 1. For late Linearity, RATA, or Cycle Time test that is passed on first attempt: data shall be invalidated from the hour of expiration of the test period until the hour of completion of the late test being performed. 2. For late 7-Day calibration error test, whether or not passed on first attempt: data shall be invalidated from the hour of expiration of the test period until the hour of completion of the late test being performed.
20 3. For late Linearity, RATA, or Cycle Time test that is failed or aborted on first attempt due to monitor issues: data shall be invalidated from the hour of the Probationary Calibration test period until the hour of completion of the late test and any additional recertification or diagnostic tests that are required to be performed as a result of changes made to correct problems that caused the failure. 4. For late 7-Day calibration error test, whether or not passed on first attempt: data shall be invalidated from the hour of expiration of the test period until the hour of completion of the late test being performed.
21 1. Whenever a calibration error test is failed or missed during a recertification test period: No further recertification tests shall be performed until the calibration error test has been passed. A missed or failed daily calibration does not restart recertification period. If failed calibration while RATA or Linearity in progress, must restart RATA or linearity. A failed calibration restarts 7-Day, if in progress.
22 2. Multi-load flow RATA where one or more load levels have passed (retest failed levels if no corrections ar made to analyzer) 3. Trial gas injections and/or trial RATA runs are permissible during the recertification test period prior to commencing a linearity check or RATA. Acceptable limits are: Gas injections: within 5% or 5 ppm of target value For RATA: within + 10% or + 15 ppm or H 2 O or lb/mmbtu (All limits are + from average ref. method value)
23 End of Presentation
SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2025
SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 2025 APPROVED: SIGNED DATE: June 14, 2007 Jon Adams Director of Compliance TITLE: SUBJECT: RULE 1080 STACK MONITORING
More informationECMPS Reporting Instructions Quality Assurance and Certification
ECMPS Reporting Instructions Quality Assurance and Certification United States Environmental Protection Agency Office of Air and Radiation Clean Air Markets Division 1310 L Street, NW Washington, DC 20005
More informationECMPS Reporting Instructions Quality Assurance and Certification
ECMPS Reporting Instructions Quality Assurance and Certification United States Environmental Protection Agency Office of Air and Radiation Clean Air Markets Division 1201 Constitution Ave, NW Washington,
More informationEd Wentling Environmental Regulatory Specialist, B&W, KVB- Enertec Products September 23, 2015
Ed Wentling Environmental Regulatory Specialist, B&W, KVB- Enertec Products September 23, 2015 Introduction What is a DAHS? Electronic Reporting Quality Assurance of Data Summary & Question A data acquisition
More informationControl Chart Methodology for Detecting Under-reported Emissions
Control Chart Methodology for Detecting Under-reported Emissions Introduction: EPA uses the control chart methodology described in this paper to analyze the CO2 concentration data recorded at coal-fired
More informationFLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION 160 W GOVERNMENT STREET, SUITE 308 PENSACOLA, FLORIDA 32502-5740 RICK SCOTT GOVERNOR HERSCHEL T. VINYARD JR. SECRETARY November 21, 2013 Ms. Dee Thompson
More informationAIR EMISSION PERMIT NO IS ISSUED TO. LSP - Cottage Grove LP
AIR EMISSION PERMIT NO. 16300087-003 IS ISSUED TO LSP - Cottage Grove LP LSP COTTAGE GROVE COGENERATION FACILITY 9525 105th Street Court South Cottage Grove, Washington County, MN 55016 The emission units,
More informationMONITORING PROTOCOL IN SUPPORT OF THE CANADA-WIDE STANDARDS FOR MERCURY EMISSIONS FROM COAL-FIRED ELECTRIC POWER GENERATION PLANTS
MONITORING PROTOCOL IN SUPPORT OF THE CANADA-WIDE STANDARDS FOR MERCURY EMISSIONS FROM COAL-FIRED ELECTRIC POWER GENERATION PLANTS The Canada-wide Standards The Canada-wide Standards (CWSs) for Mercury
More informationCommon CEMS RATA Failures and Risks. Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager
Common CEMS RATA Failures and Risks Paula Metz Alliance Source Testing, LLC Technical Services Assistant Manager Introduction Stack Testing is a labor and time intensive process and requires thorough planning
More informationECMPS Reporting Instructions Emissions
ECMPS Reporting Instructions Emissions United States Environmental Protection Agency Office of Air and Radiation Clean Air Markets Division 1201 Constitution Ave, NW Washington, DC 20004 December 16September
More informationCEMS Question/Answer Document Continuous Source Monitoring Manual Revision No. 8 (Manual) and New CEM Data Processing System (CEMDPS) DRAFT
CEMS Question/Answer Document Continuous Source Monitoring Manual Revision No. 8 (Manual) and New CEM Data Processing System (CEMDPS) DRAFT Pennsylvania Department of Environmental Protection Bureau of
More informationSANTA BARBARA COUNTY AIR POLLUTION CONTROL DISTRICT POLICIES AND PROCEDURES. Policy No Draft Div Pol Yr
SANTA BARBARA COUNTY AIR POLLUTION CONTROL DISTRICT POLICIES AND PROCEDURES Policy No. 6100.058.2016 Draft Div Pol Yr Supersedes No. 6100.058.2004 Final x Div Pol Yr Date: August 25, 2016 Pages 7 Topic:
More informationMeasurement and Reporting of Vapor Phase Mercury Emissions, Using a Sorbent Trap Monitoring System (DRAFT 9/25/08)
Measurement and Reporting of Vapor Phase Mercury Emissions, Using a Sorbent Trap Monitoring System (DRAFT 9/25/08) 1. Scope and Application The purpose of this protocol is to establish procedures for the
More informationFlorida Department of Environmental Protection Northwest District 160 Governmental Center, Suite 308 Pensacola, Florida
Florida Department of Environmental Protection Northwest District 160 Governmental Center, Suite 308 Pensacola, Florida 32502-5794 Charlie Crist Governor Jeff Kottkamp Lt. Governor Mimi A. Drew Secretary
More informationReview of ConocoPhillips Alaska Inc. Continuous Emissions Monitoring Data from a 2014 Drill Rig Study at Kuparuk Drill Site 2N
Alaska Department of Environmental Conservation Air Quality Division Review of ConocoPhillips Alaska Inc. Continuous Emissions Monitoring Data from a 2014 Drill Rig Study at Kuparuk Drill Site 2N October
More informationMaintaining Continuous Emissions Monitoring Systems To Achieve High Reliability. a technical solution to meet every need
Maintaining Continuous Emissions Monitoring Systems To Achieve High Reliability a technical solution to meet every need Tim Kuiken Western Regional Sales Manager CEMTEK Environmental 3041 S. Orange Ave
More informationCEM Istanbul, 14 th May 2014
Predictive Emission Monitoring (PEM): Suitability and Application in View of U.S. EPA and European Regulatory Frameworks CEM 2014 - Istanbul, 14 th May 2014 Thomas Eisenmann Dr. Roland Bianchin David Triebel
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT NFORMITY CERTIFICATE This is to certify that the EMIRAK Multi Gas Analyser /x (Hot Wet),, O 2 (Dry & Wet) & manufactured by: Signal Group Ltd Ambitech Division Regal Way Faringdon Oxon SN7 7BX
More informationDIVISION 4.5, CALIFORNIA CODE OF REGULATIONS, TITLE 22 CHAPTER 30. CALIFORNIA BRAKE FRICTION MATERIAL REQUIREMENTS
Regulations Text DIVISION 4.5, CALIFORNIA CODE OF REGULATIONS, TITLE 22 CHAPTER 30. CALIFORNIA BRAKE FRICTION MATERIAL REQUIREMENTS 66387.1 Definitions (a) Accredited laboratory means a laboratory that
More informationPart 60 vs. Part 75 RATA Testing Requirements. Bob Finken President Delta Air Quality Services, Inc. Orange, California
Part 60 vs. Part 75 RATA Testing Requirements Bob Finken President Delta Air Quality Services, Inc. Orange, California RATA IS.. Relative Accuracy is the absolute mean difference between the CEMS and the
More informationFlorida Department of Environmental Protection Northwest District Branch Office 2353 Jenks Avenue Panama City, Florida
Florida Department of Environmental Protection Northwest District Branch Office 2353 Jenks Avenue Panama City, Florida 32405-4389 Charlie Crist Governor Jeff Kottkamp Lt. Governor Mimi A. Drew Secretary
More informationAIR QUALITY PERMIT Issued under 401 KAR 52: Wolohan Drive, Suite 1 Ashland
Commonwealth of Kentucky Environmental and Public Protection Cabinet Department for Environmental Protection Division for Air Quality 803 Schenkel Lane Frankfort, Kentucky 40601 (502) 573-3382 AIR QUALITY
More informationGENERAL TESTING AND REPORTING REQUIREMENTS
GENERAL TESTING AND REPORTING REQUIREMENTS Ohio EPA requires that an Ohio Intent to Test ( ITT ) form be filed with the appropriate Ohio EPA representative at least 30 days (or more if required by regulation)
More informationPERMITTEE Seminole Electric Cooperative, Inc North Dale Mabry Highway Tampa, FL 33618
PERMITTEE 16313 North Dale Mabry Highway Tampa, FL 33618 Authorized Representative: James R. Frauen, Project Director Air Permit No. 1070025-004-AC Units 1-2 Pollution Controls Upgrade Facility ID No.
More informationU. S. Department of Energy. Consolidated Audit Program Treatment, Storage and Disposal Facilities. Checklist 1 Quality Assurance Management Systems
U. S. Department of Energy Consolidated Audit Program Treatment, Storage and Disposal Facilities Checklist 1 Quality Assurance Management Systems Revision 1.3 December 2013 Audit ID: Date: Quality Assurance
More informationSummary of TL 9000 R4.0 Requirements Beyond ISO 9001:2000
This summary identifies the additional TL 9000 Release 4.0 requirements beyond those stated in ISO 9001:2000. See the TL 9000 R4.0 Handbook for the actual TL 9000 R4.0 requirements. ISO 9001:2000 section
More informationDAILY LIFE of CEMS QA & PM
DAILY LIFE of CEMS QA & PM Presented at: ENVIRONMENTAL COMMITTEE TECHNICAL FOCUS GROUP December 8, 2015 DANIEL L. TODD, QEP, CHMM OVERALL CONCEPT To provide the perspective of the folks that are responsible
More informationNitric Acid Production Project Protocol Version 1.0 ERRATA AND CLARIFICATIONS
Nitric Acid Production Project Protocol Version 1.0 ERRATA AND CLARIFICATIONS The Climate Action Reserve (Reserve) published its Nitric Acid Production Project Protocol Version 1.0 in December 2009. While
More informationSupplier Quality Requirements Master List
Master List 1. Certificate Of Conformance: Certificate of Conformance must accompany each shipment. This certificate must include part numbers, standard / specification, latest applicable revision level
More informationSHASTA COUNTY DEPARTMENT OF RESOURCE MANAGEMENT AIR QUALITY MANAGEMENT DISTRICT
EXPIRATION DATE: January 3, 2020 PERMIT NO: 03-TV-02 SHASTA COUNTY DEPARTMENT OF RESOURCE MANAGEMENT AIR QUALITY MANAGEMENT DISTRICT City of Redding, Redding Power Plant (Applicant) IS HEREBY GRANTED A
More informationBUREAU OF INDIAN STANDARDS (CMD II)
BUREAU OF INDIAN STANDARDS (CMD II) Our Ref: CMD/16:15477 01 12 2006 Subject: STI for IS 15477:2004. Title: Adhesive for Use with Ceramic Tiles and Mosaics. The Scheme of Testing and Inspection for IS
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT NFORMITY CERTIFICATE This is to certify that the G-CEM 4000 In-situ Multigas Analyser manufactured by: DEL International Ltd Station Building Station Road Bakewell Derbyshire DE45 1GE UK has been
More informationIBM Security Intelligence on Cloud
IBM Terms of Use SaaS Specific Offering Terms IBM Security Intelligence on Cloud The Terms of Use ( ToU ) is composed of this IBM Terms of Use - SaaS Specific Offering Terms ( SaaS Specific Offering Terms
More information(CEMS) Sanjeev K Kanchan. Centre for Science and Environment
Continuous Emission Monitoring System (CEMS) Sanjeev K Kanchan CEMS- What & Why? Strong pollution control regime is must Unlike US, EU, developing countries suffers from weak/missingpollution norms, standardised
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the MIR-IS Multi-gas Analyser Type 2 SEC Probe manufactured by: Environnement SA 111 Boulevard Robespierre 78304 Poissy Cedex France has been assessed
More informationIBM Security Intelligence on Cloud
IBM Terms of Use SaaS Specific Offering Terms IBM Security Intelligence on Cloud The Terms of Use ( ToU ) is composed of this IBM Terms of Use - SaaS Specific Offering Terms ( SaaS Specific Offering Terms
More informationManual 058 Out of Specification Results Investigation
1 Purpose The purpose of this Guideline is to provide guidance for the investigation and response to Out of Specification (OOS) laboratory test results. 2 Scope and Applicability This Guideline applies
More informationComparison Continuous Emission Monitoring Techniques
PRODUCT DATASHEET: Comparison Continuous Comparison Continuous Emission Monitoring Techniques Overview The requirements for continuous emission monitors has changed significantly over the last 30 years.
More informationIBM Security Intelligence on Cloud
IBM Terms of Use SaaS Specific Offering Terms IBM Security Intelligence on Cloud The Terms of Use ( ToU ) is composed of this IBM Terms of Use - SaaS Specific Offering Terms ( SaaS Specific Offering Terms
More informationB. Use welding process variations (e.g., pulsed current GMAW), which can reduce fume generation rates; or
GENERALLY AVAILABLE CONTROL TECHNOLOGY For the welding operations (ID No.(s). xxx), the Permittee shall comply with all applicable provisions, including the notification, testing, and monitoring requirements
More informationABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR
White paper WP/ANALYTICAL/002 EN ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field
More informationChange is easy, right?
Change is easy, right? Incorporating New Permits, New Limits, New Controls, and New Analyzers into a new DAHS. How many changes should you make at once? Meeting compliance demands in a shifting landscape
More informationNew protocol FSSC version 4 What you need to know
New protocol FSSC 22000 version 4 What you need to know i The protocol version 4, what exactly? The FSSC 22000 certification is managed by a protocol published by the FSSC Foundation, which defines the
More informationState of New Hampshire Department of Environmental Services Air Resources Division. Temporary Permit
State of New Hampshire Department of Environmental Services Air Resources Division Temporary Permit Permit No: TP-0120 Date Issued: December 26, 2012 This certifies that: Northeast Utilities Public Service
More informationPRELIMINARY AUTHORITY TO CONSTRUCT
PRELIMINARY ISSUED BY: DATE ISSUED: SEPTEMBER XX, 2018 JORGE DeGUZMAN DATE EXPIRES: SEPTEMBER XX, 2020 ISSUED TO: SACRAMENTO MUNICIPAL UTILITY DISTRICT FINANCING AUTHORITY (SFA) COSUMNES POWER PLANT LOCATION:
More informationMonitoring Quick Guide 3
Monitoring Quick Guide 3 version 1.0 SM-QG3 - Applying BS EN 14181 Stationary Source Emissions; Quality assurance of automated measuring systems 1. Scope This Quick Guide describes the requirements for
More informationAIR EMISSION PERMIT NO ADMINISTRATIVE AMENDMENT IS ISSUED TO. Northern States Power Company
AIR EMISSION PERMIT NO. 05300015-002 ADMINISTRATIVE AMENDMENT IS ISSUED TO Northern States Power Company NSP - RIVERSIDE 3100 Marshall Street Northeast Minneapolis, Hennepin County, MN 554181826 The emission
More informationAIR EMISSION PERMIT NO IS ISSUED TO. Minnesota Power & Light The Wisconsin Public Power Inc. System
AIR EMISSION PERMIT NO. 06100004-001 IS ISSUED TO Minnesota Power & Light The Wisconsin Public Power Inc. System MINNESOTA POWER AND LIGHT - BOSWELL ENERGY P.O. Box 128 Cohasset, Itasca County, Minnesota
More informationLIGHT WEIGHT PROFILING SYSTEM
LIGHT WEIGHT PROFILING SYSTEM Calibration Verification & Operator Certification Program Manual DEPARTMENT OF TRANSPORTATION BUREAU OF MAINTENANCE AND OPERATIONS ASSET MANAGEMENT DIVISION ROADWAY INVENTORY
More informationGuidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring
Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring Section I. Introduction DEQ s Air Quality Division administers the provisions of 40 CFR Part 70 as well as the minor
More informationCompany Y Facility Z. Sample January 2019 Monthly Industrial Air Monitoring Report. EPEA Approval Number
Company Y Facility Z Sample January 219 Monthly Industrial Air Monitoring Report EPEA Approval Number -- 15 February 219 Sample January 219 Monthly Industrial Air Monitoring Report Page 1 of 4 DISCLAIMER:
More informationQuality Control Manual Submission Information
Table of Contents Quality Control Manual Submission Information 1.0 Legislative Requirement 1.1 Exemption to Legislative Requirement 2.0 Required content of Quality Control Manual 2.1 Title Page 2.2 Scope/
More informationA G. The Avogadro Group, LLC. Air Quality Consulting and Source Emissions Testing
A G The Avogadro Group, LLC Air Quality Consulting and Source Emissions Testing ALL THESE TEST RESULTS ARE THE SAME POLLUTANT FROM THE SAME BOILER!! Different test methods CAN = different results! Recent
More informationBetaGuard PM Measuring Particulate Continuously
BetaGuard PM Measuring Particulate Continuously Craig Clapsaddle McIlvaine Hot Topic December 1, 2011 MSI/Mechanical Systems, Inc. MSI / Mechanical Systems, Inc. BetaGuard PM CEM Development began in 1995
More informationCONSTRUCTION PERMIT. Public Service Company
COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT AIR POLLUTION CONTROL DIVISION TELEPHONE: (303) 692-3150 PERMIT NO: DATE ISSUED: ISSUED TO: CONSTRUCTION PERMIT 12AD2345 Public Service Company THE
More informationProcedure for Biomedical Equipment Calibration and Maintenance
Procedure for Biomedical Equipment Calibration and Maintenance 1.0 Purpose This procedure specifies the schedule and requirements for calibration, performance verification, and maintenance of Biomedical
More informationIdeal Instrument Company, Inc.
Ideal Instrument Company, Inc. Quality Control Manual Prepared By: Richard Ballantyne Quality Control Department Ideal Instrument Company, Inc. 863 Washington Canton, Ma. 020212513 Cage Code OOEU5 MCTDA
More informationDocumenta tion and Records
Documenta tion and Records Page 1 of 30 Training Outcome of the Module: After completing this module, you will be able to: Recognize the importance of procedures Recognize the importance of record keeping
More informationAMERICAN WOOD PROTECTION ASSOCIATION STANDARD 2010 All Rights Reserved
AMERICAN WOOD PROTECTION ASSOCIATION STANDARD All Rights Reserved Jurisdiction: AWPA Subcommittee T-7 This Standard has most recently been amended in 1981, 1992, 1995, 1997, 1999, 2000 2001, 2002, 2003,
More informationQuality Control Manual Submission Information
330 1855 Victoria Avenue Regina, SK S4P 3T2 PH: (306)798-7111 Toll Free: (866)530-8599 FAX: (306)787-9273 Toll Free: (866)760-9255 Website: www.tsask.ca Table of Contents Quality Control Manual Submission
More informationARKANSAS DEPARTMENT OF POLLUTION CONTROL AND ECOLOGY DIVISION OF AIR POLLUTION CONTROL. Summary Report Relative to Permit Application
ARKANSAS DEPARTMENT OF POLLUTION CONTROL AND ECOLOGY DIVISION OF AIR POLLUTION CONTROL Summary Report Relative to Permit Application Submitted By: Ash Grove Cement Company Highway 108 West P.O. Box 130
More informationNetDAHS Edge Software A proactive and centralized control hub for air compliance reporting
NetDAHS Edge Software A proactive and centralized control hub for air compliance reporting Babcock & Wilcox (B&W), the exclusiveprovider of KVB-Enertec emissions products and services, leverages the successful
More informationWellington Development WVDT, LLC Greene Energy Resource Recovery Project 3. GENERAL CONDITIONS
3. GENERAL CONDITIONS 2 a) This Plan Approval authorizes the construction of two waste coal-fired, circulating fluidized bed (CFB) boilers and a steam generator capable of producing 580 gross megawatts
More informationTEXAS DEPARTMENT OF TRANSPORTATION
TEXAS DEPARTMENT OF TRANSPORTATION SPECIFICATION NO. PREVENTIVE MAINTENANCE AND REPAIR SERVICES FOR APOGEE BUILDING AUTOMATION MANAGEMENT SYSTEM PUBLICATION This specification is a product of the Texas
More informationSCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF MALLIABLE CAST IRON PIPE FITTINGS ACCORDING TO IS: 1879:2010 (Third Revision)
SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF MALLIABLE CAST IRON PIPE FITTINGS ACCORDING TO IS: 1879:2010 (Third Revision) 1. LABORATORY: A laboratory shall be maintained which shall be suitably
More information2.2 Copies of any records and other connected papers that may be required by the Bureau shall be made available at any time on request.
SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SHORT-PITCH TRANSMISSION PRECISION ROLLER AND BUSH CHAINS, ATTACHMENTS AND ASSICIATED CHAIN SPROCKETS ACCORDING TO IS 2403:2014 1.0 LABORATORY A laboratory
More informationAIR EMISSION PERMIT NO IS ISSUED TO. Van Hoven Company, Inc.
AIR EMISSION PERMIT NO. 03700070-001 IS ISSUED TO Van Hoven Company, Inc. VAN HOVEN COMPANY, INC. 505 Hardman Avenue South South Saint Paul, Dakota County, Minnesota 55075-2413 The emission units, control
More informationProposed Data Acquisition & Handling System for Pilot Emission Trading Scheme in India
Paper to be presented during CEM 2014 Proposed Data Acquisition & Handling System for Pilot Emission Trading Scheme in India - Ms. Sujata Tilak (sujata.tilak@aiplindia.com) Abbreviations CEMS CPCB DAHS
More informationAIR EMISSION PERMIT NO IS ISSUED TO Minnesota Power & Light
AIR EMISSION PERMIT NO. 13700013-001 IS ISSUED TO Minnesota Power & Light MINNESOTA POWER AND LIGHT - LASKIN ENERGY County Road 110 and 633 Aurora, St. Louis County, Minnesota 55705 The emission units,
More informationAIR EMISSION PERMIT NO IS ISSUED TO ISPAT INLAND STEEL MINING CO
AIR EMISSION PERMIT NO. 13700062-001 IS ISSUED TO ISPAT INLAND STEEL MINING CO Ispat Inland Steel Mining Co U.S. Highway 53 North Virginia, St. Louis County, Minnesota 55792 The emission units, control
More informationSCHEME OF TESTING AND INSPECTION FOR CERIFICATION OF SISAL ROPES PART 1 UNTARRED VARIEITES ACCORDING TO IS 1321(Part 1):2003 (Fourth Revision)
SCHEME OF TESTING AND INSPECTION FOR CERIFICATION OF SISAL ROPES PART 1 UNTARRED VARIEITES ACCORDING TO IS 1321(Part 1):2003 (Fourth Revision) 1. LABORATORY- A laboratory shall be maintained, which shall
More informationCode of Practice for the TL 9000 Certification Process Release 8.0
Code of Practice for the TL 9000 Certification Process Release 8.0 This document is a product of the Oversight Work Group of the TIA Business Performance Community ( BPC ). It is subject to change by the
More informationCompany Y Facility Z. Sample 2018 Annual Industrial Air Monitoring Report. EPEA Approval Number March 2019
Company Y Facility Z Sample 2018 Annual Industrial Air Monitoring Report EPEA Approval Number 000-00-00 12 March 2019 Sample 2018 Annual Industry Air Monitoring Report Page 1 of 29 DISCLAIMER: This sample
More informationCompany Y Facility Z. Sample 2018 Annual Industrial Air Monitoring Report. EPEA Approval Number March 2019
Company Y Facility Z Sample 2018 Annual Industrial Air Monitoring Report EPEA Approval Number 000-00-00 12 March 2019 Sample 2018 Annual Industry Air Monitoring Report Page 1 of 29 DISCLAIMER: This sample
More informationSTATE OF MISSISSIPPI AIR POLLUTION CONTROL PERMIT
STATE OF MISSISSIPPI AIR POLLUTION CONTROL PERMIT AND PREVENTION OF SIGNIFICANT DETERIORATION AUTHORITY TO CONSTRUCT AIR EMISSIONS EQUIPMENT THIS CERTIFIES THAT Mississippi Silicon LLC Burnsville, Mississippi
More informationDRAWING NUMBER REVISION TITLE REV DATE PAGE
DRAWING NUMBER REVISION TITLE REV DATE PAGE 90-2000-6.2.2 J PRODUCT RESOURCES NEWBURYPORT, MA Competence, Awareness, and 9/2016 1 of 6 NOTICE: THIS DOCUMENT IS PROPRIETARY AND ITS CONTENTS ARE THE EXCLUSIVE
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the Servomex 2700 Oxygen Analyser manufactured by: Servomex Group Ltd Jarvis Brook Crowborough East Sussex TN6 3DU UK has been assessed by Sira Certification
More informationA.6 Boilers. A.6.1 New and Existing Boilers located within AQCR 131
A.6 Boilers The following are Minnesota Standards of Performance for Indirect Heating Equipment (Minn. R. 7011.0500-7011.0553) New boilers: construction, modification, or reconstruction commenced after
More informationIf I can be of any assistance, please contact me at or (479) extension 16.
July 6, 2015 Michael Tedder, Complex Manager Tyson's Foods, Inc. - Dardanelle Processing Facility P.O. Box 638 Dardanelle, AR 72834 RE: Tyson Foods, Inc. Inspections (Yell Co) AFIN: 75-00017 NPDES Permit
More informationAIR EMISSION PERMIT NO IS ISSUED TO. PowerMinn 9090, LLC 2295 Corporate Boulevard, Suite 222 Boca Raton, FL
AIR EMISSION PERMIT NO. 15100038-004 IS ISSUED TO PowerMinn 9090, LLC 2295 Corporate Boulevard, Suite 222 Boca Raton, FL 33431 And Fibrominn LLC 301 Oxford Valley Road, Suite 704A Makefield Executive Quarters
More informationCENTRAL MARKS DEPARTMENT III. Our Ref : CMD-III/16: Mar 2007
CENTRAL MARKS DEPARTMENT III Our Ref : CMD-III/16:418 13 Mar 2007 Subject : IMPLEMENTATION OF REVISED INDIAN STANDARD UNDER CERTIFICATION IS 418:2004 FOR TUNGSTEN FILAMENT LAMPS FOR DOMESTIC AND SIMILAR
More informationSAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT
SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT Proposed Revision to State Implementation Plan (SIP) to Address Federal Clean Air Act Requirements for Reasonably Available
More informationAre You Really Ready for a RATA? August 5, 2015 CIBO Portland Maine Bob Davis Project Director TRC Environmental
Are You Really Ready for a RATA? August 5, 2015 CIBO Portland Maine Bob Davis Project Director TRC Environmental So What is a RATA? R Relative A Accuracy T Test A Audit It compares data from a facility
More informationAir Division. Emissions Test Protocol And Test Report Requirements
Air Division Emissions Test Protocol And Test Report Requirements May 18, 2018 Introduction The purpose of this document is to provide guidance for test protocols and reporting stack tests under the jurisdiction
More informationInspection Report: Blytheville - West WWTP, AFIN: , Permit #: AR FACILITY TYPE: 1 - Municipal FACILITY EVALUATION RATING:
WATER DIVISION INSPECTION REPORT AFIN: 47-00544 PERMIT #: AR0022560 DATE: 8/26/2015 COUNTY: 47 Mississippi PDS #: 087290 MEDIA: WN GPS LAT: 35.934850 LONG: -89.942647 LOCATION: Entrance FACILITY INFORMATION
More informationCEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE
CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE CONTINUOUS CEMS FOR THE POWER INDUSTRY CONTENT Regulatory requirements from a European perspective (CEMS) Certification of CEMS according
More informationSTATEMENT OF BASIS for NEWARK BAY COGENERATION PARTNERSHIP L.P.
I. FACILITY INFORMATION Newark Bay Cogeneration Partnership L.P. is located at 414-514 Avenue P, Newark, New Jersey, Essex County and consists of a 120-megawatt cogeneration plant. The facility is owned
More informationdata systems CEM International Conference and Exhibition on Emissions Monitoring
Predictive Emission Monitoring (PEM): Suitability and Application in View of U.S. EPA and European Regulatory Frameworks Thomas Eisenmann 1, Dr. Roland Bianchin 2 & David Triebel 1 Contents Abstract...
More informationMonitoring cement plant stack emissions using FTIR
ABB MEASUREMENT & ANALYTICS WHITE PAPER Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field study Measurement
More informationRT Logic Maintenance Support Services
RT Logic Maintenance Support Services Document ID: RTL-COMP-002 Revision: 1.2 Date: 03 July 2014 12515 Academy Ridge View Colorado Springs, CO 80921 (719) 598-2801 8591 Prairie Trail Drive Englewood, CO
More informationINSPECTION SYSTEM REQUIREMENTS
MILITARY SPECIFICATIONS MIL-I-45208A INSPECTION SYSTEM REQUIREMENTS This specification has been approved by the Department of Defense and is mandatory for use by all Agencies. 1. SCOPE 1.1 Scope. This
More informationGeneral Accreditation Criteria Equipment assurance, in-house calibration and equipment verification
General Accreditation Criteria Equipment assurance, in-house calibration and equipment verification January 2018 Copyright National Association of Testing Authorities, Australia 2009 This publication is
More information: Rodger Jeffery (Principal Author); Hardy Engineering Team; Hardy Tech Support Team
Document : AN EXPLANATION OF TRADITIONAL AND C2 CALIBRATION/VALIDATION METHODS & USE Last Revised : Q2 2017 Authors : Rodger Jeffery (Principal Author); Hardy Engineering Team; Hardy Tech Support Team
More informationMAJOR SOURCE OPERATING PERMIT
MAJOR SOURCE OPERATING PERMIT PERMITTEE: FACILITY NAME: PINEVIEW LANDFILL PINEVIEW LANDFILL FACILITY/PERMIT NO.: 414-0013 LOCATION: DORA, ALABAMA In accordance with and subject to the provisions of the
More informationJohn Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015
John Downs Environmental Manager, B&W PGG, KVB-Enertec Products January 29, 2015 Introduction What is a CEMS? Regulatory Drivers for CEMS Quality Assurance of CEMS Summary & Question A continuous emission
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1074 CONCRETE PIPE CERTIFICATION PROGRAM FEBRUARY 12, 2003
STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1074 CONCRETE PIPE CERTIFICATION PROGRAM FEBRUARY 12, 2003 1074.01 SCOPE 1074.02 PROGRAM OVERVIEW 1074.03 MANUFACTURER CERTIFICATION PROCESS 1074.04
More informationGeneral Requirements for the Competence of Testing and Calibration Laboratories
ISO 17025:2005 POSITION PAPER General Requirements for the Competence of Testing and Calibration Laboratories EXECUTIVE SUMMARY This position paper provides a high-level overview of how LabVantage supports
More informationAIR EMISSION PERMIT NO IS ISSUED TO. BLANDIN PAPER COMPANY & Minnesota Power
AIR EMISSION PERMIT NO. 06100001-003 IS ISSUED TO BLANDIN PAPER COMPANY & Minnesota Power Blandin Paper Company 115 Southwest First Street, Grand Rapids, MN 55744-3662 Minnesota Power Blandin Energy Center
More informationPermit Number: 1900B Expiration Date: July 15, 2021
Expiration Date: July 15, 2021 GENERAL PERMIT WATER POLLUTION CONTROL FACILITIES CLASS V GEOTHERMAL FLUIDS INJECTION DURING GEOTHERMAL EXPLORATION ISSUED TO: GEN19 /NWR File No. Department of Environmental
More informationBrian Perlov, P.E. Principal Engineer
Brian Perlov, P.E. Principal Engineer Definition of MATS boiler operating day Exclusion of startup/shutdown data Diluent Capping Default electrical load Minimum Stack Flow High Replacement Values Differences
More information