PARTICIPANT BUILD PACK 1 PROCESS FLOW DIAGRAMS VER 3.6 TABLE OF TRANSACTIONS VER 3.5

Size: px
Start display at page:

Download "PARTICIPANT BUILD PACK 1 PROCESS FLOW DIAGRAMS VER 3.6 TABLE OF TRANSACTIONS VER 3.5"

Transcription

1 PARTICIPANT BUILD PACK 1 PROCESS FLOW DIAGRAMS VER 3.6 TABLE OF TRANSACTIONS VER 3.5 PREPARED BY: DOCUMENT REF: VERSION: 3.6 MARKET DEVELOPMENT DATE: 29 September 2017 FINAL :

2 Document Approval and Acceptance AEMO Approval This document has been prepared by: NAME: Position: Signature: NANDU DATAR Business Analyst Date: This document has been reviewed and conforms with the authorised changes to the Gas Interface Protocol: NAME: Position: Signature: RUTH GUEST Manager, Regulatory Date: This document has been reviewed and conforms to AEMO s regulatory obligations: NAME: Position: Signature: PETER GEERS Executive General Manager, Markets Date: Doc Ref: ver 3.5 TBA Page 2 of 49

3 Version History VERSION. DATE AUTHOR(S) CHANGES AND COMMENTS /07/10 S. Monaco Ensure document complies with AEMO standard. Replace references to MSOR with relevant NGR & RMP references. Update terminology to correspond with current usage and definitions. Update acronyms to the current vernacular. Update images Add References to Predecessors Diagram 2.0 Remove process flows 2.18, 2.19 and 2.21 which related to an asexml transaction interface between RB and DB for confirming current FRO. This asexml transaction does not exist. Diagram 2.0 Process flow 2.12 to 2.27 which relates to an asexml transaction called Meterdatahistory, which is not operational in asexml. It is however operational as an . Diagram 4.0 Remove the information bubble that made reference to reviewing Meter Route schedule being considered as an asexml. This transaction continues to be made available via . Diagram 5.4 Remove the information bubble that made reference to reviewing Meter Time Expired notice being considered as an asexml. This transaction continues to be made available via . Diagram 13.1, 13.2A, 13.3 and 13.7 yellow change marks as agreed in IN003/09 (CR96 Minor RoLR Documentation Changes) have been included. A copy of the IN003/09 GMI is available from grcf@aemo.com.au /07/12 S. Macri IN011/12 (NECF Changes) Changes for Customer Classification /02/13 J. Luu IN029/12 Pilot Program BAU Process /01/14 D. McGowan IN004/12 Redundant Provision and minor GIP and Spec Pack changes /07/14 D. McGowan IN017/13 Gas Road Map. Service Orders Review. Remove diagrams 5.1 to 5.5, 99.3 and 99.4 and add new Process Flows diagrams 100 to /07/17 N Datar IN023/15, IN028/15 and IN029/15 Harmonisation and other minor changes Doc Ref: ver 3.5 TBA Page 3 of 49

4 3.6 29/09/201 7 N Datar IN039/16 Harmonisation of T900 Password Protection changes to Diagram 13.1 Doc Ref: ver 3.5 TBA Page 4 of 49

5 Executive Summary The Table of Transactions version 3.5 contains: Table of Transactions, Table of Elements, List of Job Enquiry Codes, Address Elements and MIRN and Meter states. te: The Table of Transactions is a separate document and is not included in the electronic version of this document. References to Predecessors To reflect the governance changes implemented on 1 July 2009, this document has been amended to remove references to the Victorian Energy Networks Corporation (VENCorp) and replace such references with Australian Energy Market Operator (AEMO). Where any content inadvertently refers to VENCorp it should be read as referring to AEMO. It should be noted that participant ID VENCORP remains as the participant ID for AEMO as the gas market operator in Victoria and Queensland. Doc Ref: ver 3.5 TBA Page 5 of 49

6 Contents 1 Process Flow Diagrams Process Flow Symbols DIAGRAM 1.0 SPECIAL METER READS DIAGRAM 1.1 SPECIAL METER READS CANCELLATION DIAGRAM 2.0 BM DATA COLLECTION AND DELIVERY (PAGE 1) DIAGRAM 2.0 BM DATA COLLECTION AND DELIVERY (PAGE 2) DIAGRAM 2.7 BASIC METER CUSTOMISATION BILL ESTIMATION DIAGRAM 4.0 BASIC METER ROUTE AND SITE INFORMATION DIAGRAM 4.1 CUSTOMER DETAILS NOTIFICATION DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 1) DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 2) DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 3) DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 4) DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 5) DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 6) DIAGRAM 9.1 BM DAILY CONSUMPTION ESTIMATION DIAGRAM 10.0 DATA CHANGE DIAGRAM 11.0 BASIC METER PROFILER (BMP) DIAGRAM 12.0 MIRN REQUEST DIAGRAM 13.0 CUSTOMER REQUEST TO RETAILER RETAILER OF LAST RESORT PROCESS FLOWS DIAGRAM 13.1 PRE-ROLR EVENT MONTHLY TRANSFER OF CUSTOMER DATA TO AEMO DIAGRAM 13.2 CATS PROCESSING CANCELLED AND ACCELERATED CUSTOMER TRANSFERS DIAGRAM 13.2A CATS PROCESSING ACCELERATED CUSTOMER TRANSFERS ( MOVE INS ) DIAGRAM 13.3 NON-CATS / CUSTOMER DATA EXCHANGE AND DATA GENERATION DIAGRAM 13.4 FRB GENERATED CUSTOMER LISTS FOR ROLR DIAGRAM 13.5 WHOLESALE PROCESS DIAGRAM 13.6 ROLR COMMUNICATIONS DIAGRAM 13.7 PROVISION OF ESTIMATE TRANSFER READS AND SUBSEQUENT ADJUSTMENT DIAGRAM 13.8 SERVICE ORDERS IN FLIGHT PROCESS FLOW DIAGRAMS DIAGRAM 99.1 MAINS RENEWAL Doc Ref: ver 3.5 TBA Page 6 of 49

7 3.2 DIAGRAM 99.2 NETWORK BILLING DIAGRAM 99.4 MIRN STANDING DATA UPDATE DIAGRAM 99.5 METERED SUPPLY POINT COUNT UPDATE CUSTOMER CLASSIFICATION DIAGRAM 99.9 CUSTOMER REQUEST TO RETAILER SERVICE ORDER PROCESS FLOWS Diagram 100: Service Orders General (Simplified) Diagram 101: Retailer Initiated Service Orders Cancellation Diagram 102: Distributor Initiated Service Orders Diagram 103: Shipper Process Diagram 104: Meter Fix Request Diagram 105: Upgrade from Basic to Interval Meter Diagram 106 : Downgrade from Interval to Basic Meter For tariff D Diagram 107: Service Order Transaction Table Doc Ref: ver 3.5 TBA Page 7 of 49

8 1 Process Flow Diagrams 1. These flow charts were developed as a working aid to development of the Retail Market Procedures (Victoria) and the Participant Build Packs for the purpose of identifying the necessary transactions between Retailers, Distributors and AEMO. Whilst reasonable effort has been made to ensure that these flow charts are updated and consistent with the Retail Market Procedures (Victoria) and the Participant Build Packs, there may be differences between the flow charts and the Retail Market Procedures (Victoria) and the Participant Build Packs. Where there is a difference, the Retail Market Procedures (Victoria) and the Participant Build Packs take precedence. 2. The process steps within individual business are indicative only and do not necessarily identify all required process steps nor do they mandate the use of a particular process. 3. The drawing conventions used for these diagrams are as follows: a. Multiple flow arrows exiting from a process step indicate two or more independent process flows that occur following the step. If a flow is conditional, that condition will be noted on the flow arrow. b. Alternative flows are indicated by a decision box containing a question. Conditions based on answers to the question on the flows exiting these boxes will be noted on the flow arrows. c. A fork synch bar indicates two unconditional parallel processes that will rejoin at some point with a join synch bar. A join indicates that all processes must be completed before moving on. 4. Flow arrows that cross swim lanes to connect to a start or end identifier are used to ease diagram production and do not indicate a B2B transaction. Doc Ref: ver 3.5 TBA Page 8 of 49

9 1.1 Process Flow Symbols The drawing conventions used for these diagrams are as follows: N.N Activity Decision Decision/Data Transfer Description Process Terminator/ Inter-process Link On Page Ref Process Close Process Start Wait Parallel Mode asexml Message Description Association tes Doc Ref: ver 3.5 TBA Page 9 of 49

10 MBMR BMDM Distributor AEMO Retailer (New or Existing FRO) Customer 1.2 DIAGRAM 1.0 SPECIAL METER READS Diagram 1.0 Special Meter Reads 1.1 Requests special read From 6.0 Customer Transfer Page Requires special read 1.3 minate date and generate special read request 1.21 Log Work Order Number 1.17 Will retailer carry out special read? 1.8 Issues request to contractor for debt collection or disconnection 1.9 If debt un paid disconnect and read meter. Forward meter read and disconnection flag to DB 1.13 Update New FRO CIS SpecialReadResponse SpecialReadResponse SpecailReadRequest MeterReadInputtification From 6.0 Customer Transfer Page CATStification AccountCreationtification 1.11 Close Special Read Request and advise RB 1.20 Return Work Order Number 1.4 Log request and forward to Meter Reading Contractor From 10.0 Data Change Update MIRN and Meter Data database with disconnection status 1.16 Receive Transfer Completion tification 1.14 Send New FRO Meter Index, data and site data 1.19 Was meter disconnected? 2.0 Basic Meter Data Collection and Delivery Transfer Required? 1.10 Record reason for no access and advise DB 1.20 Was it Special Final Read? 1.18 Attend site. Access available? 1.21 Perform Estimation 1.5 Record reading and if requested disconnect 1.6 Perform basic high/low validation 1.7 Send read data to BMDM Doc Ref: ver 3.5 TBA Page 10 of 49

11 Distributor Retailer 1.3 DIAGRAM 1.1 SPECIAL METER READS CANCELLATION Diagram 1.1 Special Meter Reads Cancellation 1.22 Special Read no longer required minate date and generate Special Read Request 1.23 Raise Special Read Cancellation request SpecialReadRequest 1.24 Log Special Read Cancellation Close Special Read Request and advise RB Doc Ref: ver 3.5 TBA Page 11 of 49

12 MBMR BMDM Distributor AEMO Retailer Customer 1.4 DIAGRAM 2.0 BM DATA COLLECTION AND DELIVERY (PAGE 1) Diagram 2.0 BM Data Collection and Delivery (Page 1) Page Card Read <<Phone>> 2.16 Call Centre Read <<Mail>> MeterReadInputtification 2.1a Calculate Validation Parameters From 5.5 Basic Meter Removal & From 5.1 Basic Meter Fix From 5.2 Basic Meter Change From 99.3 Service Orders From 5.3 Basic Meter Upgrade to interval Download reading route schedule and validation parameters to meter reading contractor From 4.0 Basic Meter Route and Site Information Store and validate data 2.7 Obtain estimated index data as required via process 2.7 Basic Meter Customer Bill Estimation Go to 1.0 Special Meter Read Subtract previous index read from current index read A (to page 2) 2.2 Load reading route schedules into PDEs 2.3 Follow route schedule and key reads into PDEs From 1.0 Special Meter Reads 1.9.1, 1.19 & Upload read data 2.31 Leave card 2.30 Able to read meter? 2.4 Perform basic high/low validation, update site info as required Doc Ref: ver 3.5 TBA Page 12 of 49

13 MBMR BMDM Distributor AEMO Retailer Custom er 1.5 DIAGRAM 2.0 BM DATA COLLECTION AND DELIVERY (PAGE 2) Diagram 2.0 BM Data Collection and Delivery (Page 2) Page Bill end customer 2.28 Identify any missing energy data 2.24 process energy data 2.29 Request missing energy data 2.26 Request Energy History 2.25 Return Meter Data Response 2.23 Save energy data 2.27 Save Energy History data From 11.0 Basic Meter Profiler (BMP) Basic Meter Profiler (BMP) 11.1 MeterDataResponse MeterDataMissingtification <<asexml(csv)>> MeterDataResponse MeterDatatification <<asexml(csv)>> Request Gas History Data <<fax or >> 2.16 Calculate bill/ DUoS MeterDatatification (2 nd tier) <<asexml(csv)>> A (from page 1) Metric Data? 2.10 Apply PCF 2.9 Convert imp to metric MeterDataMissingtification 2.11 Apply average heating value 2.22 Process Energy Data Response MeterDataHistoryResponse << (CSV)>> 2.12 Provide Energy and/or flow data and or index readings From 9.1 BM Daily Consumption Estimation From 10.0 Data Change 10.5 Doc Ref: ver 3.5 TBA Page 13 of 49

14 MBMR BMDM Distributor AEMO Retailer Customer 1.6 DIAGRAM 2.7 BASIC METER CUSTOMISATION BILL ESTIMATION Diagram 2.7 Basic Meter Customisation Bill Estimation Provide Customer Characterisation Provide EDD Provide ave. daily flow weighted Heating Values AmendMeterRouteDetails <<asexml (CSV)>> <<MIBB>> <<MIBB>> From 2.0 Basic Meter Data Collection and Delivery 2.6 Consumption history > 1yr? Determine ave BL & ave TSF from Customer Characterisation Estimate Daily Consumed Energy using BL & TSF Convert Estimated Consumed Energy to flow Go to 2.0 Basic Meter Data Collection and Delivery 2.8 Doc Ref: ver 3.5 TBA Page 14 of 49

15 MBMR BMDM Distributor AEMO Retailer Customer 1.7 DIAGRAM 4.0 BASIC METER ROUTE AND SITE INFORMATION Diagram 4.0 Basic Meter Route and Site Information 3.1(a) Customer Requests changes to address information (eg Lot number to Hse Number 3.1(b) Customer Requests changes to site information (eg Access to Meter) 4.3 Consultation on Route/Route Changes 4.5 Record annual meter read schedule 4.4 Record route changes 3.2(a) Retailer records and issues request to update address information 3.2(b) Retailer records and issues request to update site information <<Phone, fax, >> Annual meter read schedule << (CSV), web>> AmendMeterRouteDetails << (CSV)>> AmendMeterRouteDetails AmendMeterRouteDetails From 5.3 Basic Meter Upgrade to Interval Update Meter Data Database 3.3 Receives and acknowledges change to Site Information From 5.1 Basic Meter Fix Analyse and optimise routes 4.2 Update/Create route schedules based on outputs Go to 2.0 Basic Meter Data Collection and delivery Meter Reading Service Provider requests changes to site information (eg Access to Meter, Address details) Doc Ref: ver 3.5 TBA Page 15 of 49

16 Distributor Retailer Customer 1.8 DIAGRAM 4.1 CUSTOMER DETAILS NOTIFICATION Diagram 4.1 Customer Details tification 3.1c Customer request change to contact details 3.1d Customer request move in and provides contact details 3.2c Retailer records details and issues request to update contact details AmendCustomerDetails <<asexml CSV>> 3.6 Update Customer contact Database 3.3 Receives and acknowledges change to customer contact details Doc Ref: ver 3.5 TBA Page 16 of 49

17 Distributor TPO Current FRO AEMO New FRO Customer 1.9 DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 1) Diagram 6.0 Customer Transfer (Page 1) Page Provide implicit informed consent Further processing as per problem notice handling. Refer to Page 6 From 12.0 MIRN Request Submit Transfer Request to CATS CATSChangeRequest Process Response to Transfer Request CATSChangeResponse [If special read is required] Go to 1.0 Special Meter Reads Receive Problem tice CATSChangeAlert Initiate Transfer Transaction tify New Retailer Request Standing Data Receive Standing Data I (to page 4) tify Affected Parties Is it move-in transfer? B(to page 3) D(to page 4) Generate Problem tice CATStification CATSChangeResponse <<manual process>> Receive tice of Transfer A(to page 2) CATSDataRequest CATSChangeRequest CATStification Receive tice of Transfer NACK [] Deliver Standing Data Process Response to Standing Data Is it re Retrospective Transfer & no reading for that date? Put on tice to Deliver Energy for this site in the Allowable Period Doc Ref: ver 3.5 TBA Page 17 of 49

18 Distributor TPO Current FRO AEMO New FRO Customer 1.10 DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 2) Diagram 6.0 Customer Transfer (Page 2) Page Consider Valid Objection CATStification B (to page 3) Validate Objection Register Objection tify Objecting Party tify Affected Participants C (to page 3) CATSObjectionRequest CATSObjectionResponse A (from page 1) Object? Enter Objection in CATS Process Objection Response G (to page 3) CATStification Receive tice of Objection Doc Ref: ver 3.5 TBA Page 18 of 49

19 Distributor TPO Current FRO AEMO New FRO Customer 1.11 DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 3) Diagram 6.0 Customer Transfer (Page 3) Page 3 B (from page 2) Receive notice of objection withdrawal CATStification H(from page 5) Receive cancelled Txf notice Liaise/ tify with Customer C (from page 2) Monitor objection period [objection period expired] CATStification Clear objection Send notice of objection withdrawal Any Objection? Cancel transfer request Send cancelled Txf notice CATStification CATSObjectionWithdrawal CATStification G (from page 2) Resolve objection Receive notice of objection withdrawal D(to page 4) CATStification Receive cancelled Txf notice End Process CATStification Receive notice of objection withdrawal Receive cancelled Txf notice End Process Receive notice of objection withdrawal Receive cancelled Txf notice Remove from the transfer queue to deliver energy Doc Ref: ver 3.5 TBA Page 19 of 49

20 Distributor TPO Current FRO AEMO New FRO Customer 1.12 DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 4) Diagram 6.0 Customer Transfer (Page 4) Page Receive status update E(from page 5) I (from page 1) CAStification Update CIS CATStification Process Close D(from page 1 and 3) Set transfer status to Pending Send status change notice Wait for final read data Load actual meter read data From 11.0 Basic Meter profiler (BMP) Is read an Actual read? Update status to Completed Is Read Date OK for Transfer tify affected participants Has standing data been provided? Update Meter Register Process Close CATStification CATStification Receive status update F (to page 5) Issue Final Bill Process Close CATStification CATStification Update DUoS/TUoS Billing Process Close Receive status update Update Data Access Controls Go to 1.0 Special Meter Reads 1.16 Process Close Doc Ref: ver 3.5 TBA Page 20 of 49

21 Distributor TPO Current FRO AEMO New FRO Customer 1.13 DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 5) Diagram 6.0 Customer Transfer (Page 5) Page 5 AEMO will automatically cancel the Transfer Request if a New Transfer Date or a Cancellation is not received within 10 business days H (to page 3) H (to page 3) Exception Processing CATSDataRequest Has read fail notice been issues? Receive transfer cancellation notice [Cancel] CATSChangeWithdrawal CATStification CATSChangeRequest [New transfer date] Process Close Process response CATSChangeResponse F (from page 4) Is it re Retrospective transfer Has read fail notice been issued? tify Late Meter Read tify new retailer of final read failure Set transfer status to cancelled tify affected participants Update status with new transfer date tify affected participants E (to page 4) CATSDataRequest CATStification CATStification Receive tice of Read Failure Receive transfer cancellation notice Process Close Receive notice CATSDataRequest CATStification CATStification Receive notice of read failure Receive transfer cancellation notice Process Close Receive notice Doc Ref: ver 3.5 TBA Page 21 of 49

22 Distribution TPO Current FRO AEMO New FRO Customer 1.14 DIAGRAM 6.0 CUSTOMER TRANSFER (PAGE 6) Diagram 6.0 Customer Transfer (Page 6) Page Receive problem notice CATSChangeAlert Pass problem notice to new retailer CATSChangeAlert CATSChangeAlert <<manual process>> Generate problem notice Generate problem notice Generate problem notice Doc Ref: ver 3.5 TBA Page 22 of 49

23 MBMR BMDM Distributor AEMO Retailer Customer 1.15 DIAGRAM 9.1 BM DAILY CONSUMPTION ESTIMATION Diagram 9.1 BM Daily Consumption Estimation This diagram is for AEMO internal use only. t to be used for participant design Go to 11.0 Basic Meter Profiler (BMP) From 11.0 Basic Meter Profiler (BMP) Consumed energy available? Estimate daily consumed energy using BL & TSF NMIStandingDataUpdatetification See also diagram 11.0 BMP ( > 11.17) Provide BL & TSF Doc Ref: ver 3.5 TBA Page 23 of 49

24 MBMR BMDM Distributor AEMO Retailer Customer 1.16 DIAGRAM 10.0 DATA CHANGE Diagram 10.0 Data Change 10.1 Customer complaint re bill 10.3 Request data quality confirmation and provide clarifying information (where applicable) 10.2 Consider complaint data problem? 10.6 Manage customer/ complaint MeterDataVerifyRequest MeterDataVerifyResponse 10.4 Initiate special read (Special Read) 10.8 Alternative re-estimate or special read required (Alternative re-estimate) 10.7 Carry out alternative reestimation 10.5 Inform RB of re-estimation or special read result (If new energy data Is to be supplied) Go to Basic meter data collection and delivery Special Meter Reads 1.4 Doc Ref: ver 3.5 TBA Page 24 of 49

25 MB MR BMDM Distributor AEMO Retailer Customer 1.17 DIAGRAM 11.0 BASIC METER PROFILER (BMP) Diagram 11.0 Basic Meter Profiler (BMP) Generate values/site without reading Meter data store 11.4 Apply UAFG benchmark 11.9 MIBB Calculate EDD values Monitor energy data Go to 6.0 Customer Transfer Aggregate energy readings by RB by DB 11.8 Settlements Process Update meter register with BL and TSF NMIStandingDataUpdatetification Send response to BL and TSF by Site update NMIStandingDataUpdateResponse 22.1 Are all MIRNs present? Request missing energy data 11.1 Validate data 11.6 Apply profile to aggregated energy 11.7 Profile preparation (PPS) Meter Data Store Deliver BL and TSF by Site Process response to BL and TSF by site update MeterDatatification(2 nd tier) MeterDataMissingtification MeterDataResponse 2.0 Basic Meter Data Collection and Delivery 2.12 Go to 2.0 Basic Meter Data Collection and Delivery 2.22 Doc Ref: ver 3.5 TBA Page 25 of 49

26 MBMR BMDM Distributor AEMO Retailer Customer 1.18 DIAGRAM 12.0 MIRN REQUEST Diagram 12.0 MIRN Request 12.2 Provide explicit informed consent, MIRN or address Contact DB for details 12.9 Can RB resolve 12.3 Initiate MIRN Discovery transaction 12.8 Use Data <<Phone, fax, >> NMIDiscoveryResponse/ NMIStandingDataResponse NMIDiscoveryResponse/ NMIStandingDataRequest NMIDiscoveryResponse/ NMIStandingDataResponse NMIDiscoveryResponse/ NMIStandingDataResponse 12.3 Manage query on failed searches Return error 12.5 Single match on Address/MIRN 12.6 Provide MIRN Data If additional Data to be supplied 12.7 Provide additional MIRN Data Doc Ref: ver 3.5 TBA Page 26 of 49

27 Customer FRO AEMO Retailer (t FRO) Customer 1.19 DIAGRAM 13.0 CUSTOMER REQUEST TO RETAILER Diagram 13.0 Identifying a Gas Customer s Current Retailer (Meter and/or Up Stand Removed) 1. Customer Calls RB who is not FRO to Arrange SO 7. Customer Happy 2. Receives call from customer. Advises customer they are not the RB for that address. Take customer s details. SO details are taken. 3. RB B2B Contact (Primary/Secondary) send AEMO Helpdesk for Identify FRO 4. Helpdesk logs call and searches meter register for current FRO 5. AEMO pass customer details to FRO and closes call 6. FRO contact customer and collects SO details 8. Organise Service Order (If required) 9. Receive service order request and complete Doc Ref: ver 3.5 TBA Page 27 of 49

28 Regulator AEMO n-host Retailers 2 RETAILER OF LAST RESORT PROCESS FLOWS 2.1 DIAGRAM 13.1 PRE-ROLR EVENT MONTHLY TRANSFER OF CUSTOMER DATA TO AEMO Diagram 13.1 Pre-RoLR Event Monthly Transfer of Customer data to AEMO Generate Customer List, M+10 b/days for each month Compressed CSV Format 1. T905 / INT 601 Error Advice sent 2. Warning tice Sent by T900 / INT600 via FTP / MIBB Process File Are there Errors? File Received within 15 Bus Days? File Received within 10 Bus Days? Store current validated data tification of Breach Periodic Audit of Data Errors include - Validation against AEMO Mater Register to match MIRNs in AEMO Meter Register = <warning> - Field contents where required / mandatory = <error> - Archive old file as new file delivered and validate with no error - For the avoidance of doubt AEMO maintains current file in database only Doc Ref: ver 3.5 TBA Page 28 of 49

29 FRB Old FRO New FRO Distributor AEMO 2.2 DIAGRAM 13.2 CATS PROCESSING CANCELLED AND ACCELERATED CUSTOMER TRANSFERS Diagram CATS Processing Cancelled and Accelerated Customer Transfers (transfers Lodged in CATS) Retrospective Transfer? RoLR Initiated Cancel Transfers (RCA) To FRB? A Move In? Accelerate Transfers (RCO) To 13.2A 13.2A.1 From 13.2A 13.2A.2 Retrospective Transfers - Prior to RoLR Allow to proceed Away from FRB Accelerated To FRB accelerated and then RoLR ed via 13.3 CATS Transfers tices include two new Change Status Codes - RCA - RoLR Cancellation RCO Accelerated RoLR Transfer AEMO Standard BMP processes New FRO could be RoLR or any other retailer T930 (224) asexml Cancelled Transfer Current Transaction 1. T960 (229) asexml RoLR Accelerated 2 INT607 MIBB report 1.T940 (226) asexml RoLR Accelerated 2. INT607 MIBB report Day tice of Accelerated Customer Transfers tice of cancelled Customer Transfers tice of Customer Transfers away from FRB Day tification to new FRO T12 asexml Account Creation Complete transfers into new FRO (NB Customer provided data with original requests) Estimates to AEMO and FRB Day 5 T990(52) asexml (MDN) Estimate Reads Changed to Actual for AEMO Day 6 T920 (223) asexml Cancelled Transfer Current Transaction tice of cancelled Customer Transfers Transaction 995(51) asexml (MDN) T910 (222) asexml Cancelled Transfer 1. T950 (227) asexml RoLR Accelerated 2 INT607 MIBB report tice of Customer Transfers away from FRB tice of cancelled Customer Transfers Generate Final Bill Doc Ref: ver 3.5 TBA Page 29 of 49

30 FRB Old FRO New FRO Distributor AEMO 2.3 DIAGRAM 13.2A CATS PROCESSING ACCELERATED CUSTOMER TRANSFERS ( MOVE INS ) Diagram 13.2A - CATS Processing Accelerated Customer Transfers ("Move Ins") (transfers Lodged in CATS) Day 0 (Calendar Days) (from suspension to 6.00 am (next Gas Day) From A 13.2A.1 Is minated Transfer Date < 10 days from RoLR date New Customer (Move-In) Old Customer (Move-Out) 13.2A.3. Transfer occurs under normal processing. Transfer move- ins to new retailer on RoLR Date 13.2A.2 Update minated Transfer date to RoLR date To To Transfer move- out accelerated to RoLR Date Transfer move- ins dealt with under error processing New FRO could be RoLR or any other retailer 10 Days established to allow for: 1. industry knowledge of time periods for move in & outs (premises vacant for ~5 days) 2. Cost of gas for 10 days ~$1/day = $10 marginal (per SA deemed reads process) 3. Under 10 days move in customer may not be aware of Failed RB 4. Over 10 days move in customer can negotiate with new RB Day 0 Day > A.4. Receive Standard WIN tification 13.2A.5. Receive AEMO Manual Loss tification Known consequence: Where the RoLR is the New FRO, they will receive the MIRN when the existing site is RoLR ed and when the transfer occurs 13.2A.6. Receive Standard Loss tification Doc Ref: ver 3.5 TBA Page 30 of 49

31 FRB RoLRs Distributor AEMO 2.4 DIAGRAM 13.3 NON-CATS / CUSTOMER DATA EXCHANGE AND DATA GENERATION Diagram 13.3 n-cats / Customer Data Exchange and Data Generation Day 0 (Calendar Days) (from suspension to 6.00 am (next Gas Day) RoLR Gas Day RoLR Initiated AEMO updates Meter Register Set FRO = RoLR Std Settlement & Reporting Processes Customer list T970 and T980: Includes all MIRNs with the FRB that are not transferred in CATS (with an RCO/RCA type) Old Customer (Move Out) Process FRB Customer List against Metering Register Issue List RoLR transfers to DBs T980 (Via MIBB) From AEMO Meter Register T990 (52) asexml (MDN) Receive Final estimated Read for all Basic meter data for FRB T990 (52) asexml (MDN) Std Interval Metering data stream for RoLR & others T970 / INT602 (Via MIBB) Update MIRNS to RoLR Generate Basic Meter Reads for Transfer of FRB Customers (as per ) Generate Standing data (all MIRNS) & Basic Meter Reads for RoLR Std basic Meter data stream RoLR & others Receive Customer Details b Prepare CIS accounts for RoLR Customers From Assess Customer data T995 (51) asexml (MDN) 1. MIRN Standing Data T1000 via CD 2. Account Creation T1005 via CD Receive Standing Data & Start Reads Receive Final Estimated Read for all Basic Customers Prepare CIS accounts T995 (51) asexml (MDN) Std Billing Final Bill Doc Ref: ver 3.5 TBA Page 31 of 49

32 FRB Distributor RoLRs AEMO 2.5 DIAGRAM 13.4 FRB GENERATED CUSTOMER LISTS FOR ROLR Diagram FRB Generated Customer List for RoLR Activity in Calendar Days Day RoLR Receives Customer List from FRB To 13.3 T1010 via CD From FRB Sends Customer List to RoLRs Doc Ref: ver 3.5 TBA Page 32 of 49

33 RoLR AEMO 2.6 DIAGRAM 13.5 WHOLESALE PROCESS Diagram Wholesale Process Day 0 (Calendar Days) (from suspension to 6.00 am (next Gas Day) RoLR Initiated AEMO Generates Data for RoLR Implement Administered Price Cap (APC) AMDQ Block V allocations Updated to reflect RoLR transfers Do for Day 0 1. T1020 / INT604 (Similar to INT055 with FRB details) 2. T1030 / INT605 (Similar to INT254 with FRB interval data) RoLR receives wholesale data Standard Wholesale Market activities Doc Ref: ver 3.5 TBA Page 33 of 49

34 FRB Distributor RoLR ESC AEMO 2.7 DIAGRAM 13.6 ROLR COMMUNICATIONS Diagram RoLR Communications RoLR Imminent AEMO advises Regulator VENCorp / ESC MoU Day 0 (Calendar Days) (from suspension to 6.00 am (next Gas Day) RoLR Initiated by AEMO AEMO advises Industry AEMO Comms - Advice sent using an to the B2B Contact List RoLR Contact (X2) - Message sent with: read receipt on and as high priority - Advice to RoLRs regarding Number of MIRNs involved and estimate of load Regulator Liaises with Minister & DPI Day 1 or Greater RoLR Initiated by Regulator Regulator Advises Industry Day Regulator advises FRB of Obligations RoLR requests customer list from FRB DB prepares RoLR event To FRB generates Customer List Doc Ref: ver 3.5 TBA Page 34 of 49

35 FRB Distributor RoLR ESC AEMO 2.8 DIAGRAM 13.7 PROVISION OF ESTIMATE TRANSFER READS AND SUBSEQUENT ADJUSTMENT Diagram Provision of Estimate TFR Reads and Subsequent Adjustment NB: monthly cycle in business days Receive Final estimated Read changed to Actual for all Basic meter data for FRB Receive 2nd tier meter data By M+118 b/days for settlement Receive 2nd tier meter data T990 (52) asexml T1000 / T1005 Via CD Receive Standing Data & Start Reads (as per ) Business Day 5 - Transaction 42 asexml - Transaction 41 asexml Receive MDN Transaction 42 asexml Receive MDN Business Day Month Generate Basic Meter Reads for Transfer of FRB Customers (as per ) Basic Meter Reads obtained post Transfer of FRB Customers Is there an error with the transfer estimate? Adjust as Required Transaction 41 asexml T995 (51) asexml (MDN) Receive Estimate Read for all Basic Customers (as per ) Transaction 41 asexml Receive MDN Doc Ref: ver 3.5 TBA Page 35 of 49

36 FRB Distributor RoLR AEMO Regulator 2.9 DIAGRAM 13.8 SERVICE ORDERS IN FLIGHT Diagram 13.8 Service Orders "in flight" Activity in Calendar Days NB: monthly cycle in business days te: Any mismatches between the Meter Registers of the RoLR, DB and AEMO will be identified and fixed in the post RoLR Reconciliation, if required Identify Meter Fix's assiigned to FRB post RoLR event Update to RoLR for Reconciliation by Month b/days T1050 via List of Cancelled Service Orders RoLR receives report from DB of FRB cancelled Service Orders Day Once data receive from determine if Service Order is to be raised MeterFix asexml transaction (Std) T1060 / INT606l List of Meter Fixes Via MIBB RoLR receives report from VENCorp of Meter Fixes Identifies FRB Service Orders that are yet to "complete" and will be cancelled and generate RoLR report Complete Service Orders (that are not cancelled) Transaction (315) SO Completion asexml transaction (std) T1040 (315) asexml Cancelled Service Order Transaction tice of cancelled Service Order tice of completed Service Orders Doc Ref: ver 3.5 TBA Page 36 of 49

37 Distributor Retailer 3 PROCESS FLOW DIAGRAMS 3.1 DIAGRAM 99.1 MAINS RENEWAL Diagram 99.1 Mains Renewal Record impacted MIRNs FieldWorktification << (CSV)>> tify Retailer of impacted MIRNs Identify maintenance work requirement Identify impacted MIRNs tify impacted customers as required Doc Ref: ver 3.5 TBA Page 37 of 49

38 Distributor Retailer 3.2 DIAGRAM 99.2 NETWORK BILLING Diagram 99.2 Network Billing Record network DUoS billing details data [disagreement with billing details] Issue a dispute Review proposed dispute resolution NetworkDUoSBillingtification <<asexml (CSV)>> NetworkDUoSBillingtification <<asexml (CSV)>> NetworkDUoSBillingtification <<asexml (CSV)>> NetworkDUoSBillingtification <<asexml (CSV)>> Collate network DUoS billing details data Review network DUoS billing details and propose a resolution Record Payment Details Doc Ref: ver 3.5 TBA Page 38 of 49

39 Distributor Retailer 3.3 DIAGRAM 99.4 MIRN STANDING DATA UPDATE Diagram 99.4 MIRN Standing Data Update Update MIRN Standing Data << >> Update MIRN Standing Data tify Retailer of change Doc Ref: ver 3.5 TBA Page 39 of 49

40 Distributor AEMO 3.4 DIAGRAM 99.5 METERED SUPPLY POINT COUNT UPDATE Diagram 99.5 Metered Supply Point Count Update Update metered supply points count MeteredSupplyPointsCountUpdate Providing metered supply points count Doc Ref: ver 3.5 TBA Page 40 of 49

41 Distributor Retailer 4 CUSTOMER CLASSIFICATION 4.1 DIAGRAM 99.9 CUSTOMER REQUEST TO RETAILER Diagram 99.9 Customer Request to Retailer AGREED - Request from Customer to RB Receive Customer request Has the primary use of the property changed? Generate Amend Route/Site Address Details Transaction Receive Amend Route/Site Address Details transaction and update system(s) Receive transaction with updated Customer Classification Code Generate Amend Route/Site Address Details Transaction Where CCC is BUS Update Customer Threshold Code ( LOW, MED, HIGH Send Update Doc Ref: ver 3.5 TBA Page 41 of 49

42 AEMO Distributor Retailer Customer 5 SERVICE ORDER PROCESS FLOWS 5.1 Diagram 100: Service Orders General (Simplified) Diagram 100: Service Orders General (Simplified) SA Process Ref: PF (B2B) REQ5B/MIRN 1 1. Request a Service Where rejected, Retailer takes appropriate action e.g. Initiate new service order request and current process ends. Wait for service order response Closure From or or as applicable 1a. Request a Service 3. Receive Service Order Request & Validate ServiceOrderRequest [actiontype= New ] #1 4. Valid Service Order Request? Go To Send Service Order (SO) C-K 5. Send Validation Outcome Transaction Acknowledgment 9. Log Service Order & Send Response 12. Was Additional or Alternative Work Completed? 6. Receive Acceptance/ Rejection From Action Service Order 7. Was Service Order Accepted? If required by service requested ServiceOrderResponse [responsetype= Initial ] #2 Go To or as applicable 11. Has SO been Completed? Go To 2.0 Meter Data Delivery 8. Receive Service Order Response (Initial) Up to 5 BD From Expected Completion of Step Send Service Order Response Up to 5 BD from Expected Completion of Step Does SO Type Require Delivery of Meter Data? ServiceOrderResponse [responsetype= Closure ] #3 15. Receive Service Order Response (Closure) 14. Upgrade or Downgrade? 17. Does SO Require tification to AEMO? Go To or as applicable 18. Send tification to AEMO #4 This process wasn t reviewed as part of IN017/13. IN027/13 has been created to raise awareness that when Meter Data Delivery process is reviewed revisit this process flow diagram 19. Action tification #1, 2, 3 & 4 Refer to Diagram 107 for the transactions involved Doc Ref: ver 3.5 TBA Page 42 of 49

43 Distributor Retailer Customer 5.2 Diagram 101: Retailer Initiated Service Orders Cancellation Diagram 101: Retailer Initiated Service Orders Cancellation SA Process Ref: PF (B2B) REQ 7 1. Request a Service order to be Cancelled Same day cancellations must also be phoned through Where cancellation is rejected the original SO will continue to be actioned Retailer takes appropriate action 1a. Request a Service order to be Cancelled 2. Send Service Order (SO) Cancellation C-K 6. Receive Acceptance/ Rejection 7. Was SO Cancellation Accepted? 8. Receive Service Order Response 9. Update System Data ServiceOrderRequest [actiontype= Cancel ] #1 Transaction Acknowledgment ServiceOrderResponse [responsetype=closure] #3 Up to 5 BD from Expected Completion of Step Receive Service Order Cancellation & Validate 5. Send Validation Outcome 12. Send Service Order Response 4. Valid Service Order Cancel Request? 10. Attempt to Cancel Initial SO Request 11. Can Initial SO be Cancelled? Where cancellation is rejected the original SO will continue to be actioned #1 & 3 Refer to Diagram 107 Table for the transactions involved Doc Ref: ver 3.5 TBA Page 43 of 49

44 AEMO Distributor Retailer 5.3 Diagram 102: Distributor Initiated Service Orders Diagram 102: Distributor Initiated Service Orders SA Process Ref: PF (B2B) REQ 6 Distributor initiated work at the site requires update to retailer/aemo This includes Time Expired Meters 3. Receive & Validate Service Order Response (C-K) 4. Update System Data ServiceOrderResponse [responsetype=closure] #3 1. Complete Field Work 2. Send Service Order Response (C-K) 5. Does SO Require tification to AEMO? From Go To 2.0 Meter Data Delivery 6. Does SO Type Require Delivery of Meter Data? 7. Send tification to AEMO #4 This process wasn t reviewed as part of IN017/13. IN027/13 has been created to raise awareness that when Meter Data Delivery process is reviewed revisit this process flow diagram 8. Action tification #3 & 4 Refer to Diagram 107 Table for the transactions involved Doc Ref: ver 3.5 TBA Page 44 of 49

45 Distributor Retailer Customer 5.4 Diagram 103: Shipper Process Diagram 103: Shipper Process SA Process Ref: MIRN1.1 Part 2 1. Request a Service The request for work Form is different for each DB If rejected, resolve issues with customer and resend Shipper Form (potentially amended) Phone/Fax/ 12. Accept Cost / Conditions? Phone /Fax From or or as applicable 2. Prepare Shipper Form 11. Advise Customer of Costs / Conditions & Send Offer 13. Receive Signed Agreement 15.Is SO Required for the Service by the Applicable DB? Go To 100.1a 6. Receive Validation Outcome 1a. Request a Service 10. Receive Shipper Response /Fax From or as applicable 1b. Request a Shipper 3. Receive & Validate Shipper Form 5. Send Validation Outcome 8. Does the Site Match Shipper Form? 9. Complete Shipper Evaluation Form & Send Response 14. Receive Signed Shipper Acceptance From or as applicable 4. Valid Shipper Request? 7. Review Field Requirements and/or Visit Site Tariff V requires response within 10 business days from request received otherwise date agreed by the customer Go To or or or as applicable tes: Service Order Enquiry Code MAP, MFX, MRT, RSR, SCR, UMS, USR Doc Ref: ver 3.5 TBA Page 45 of 49

46 Retailer Customer 5.5 Diagram 104: Meter Fix Request Diagram 104: Meter Fix Request SA Process Ref: NA 1. Request Meter Fix as Service & Fitting Lines Completed 5. Customer Quotes CoC & PLN 8. Customer Quotes Start Work tice & PLN 2.Simple Meter Type Installation? 4. Request Customer to Provide CoC & PLN 6. Valid CoC & PLN? Go To 100.1a 3.Is a Shipper form required? 7. Request Customer to Provide Start Work tice & PLN Go To From Doc Ref: ver 3.5 TBA Page 46 of 49

47 AEMO Distributor Retailer Customer 5.6 Diagram 105: Upgrade from Basic to Interval Meter Diagram 105: Upgrade from Basic to Interval Meter SA Process Ref: PF (B2B) MR12 1. Request Upgrade to Interval Meter Go To If required by service requested 2. Retailer identifies need for Basic to Interval Meter Upgrade Go To 103.1a From From Receive Completion Advice or ServiceOrderResponse Go To 103.1b 3. Distributor identifies need for Basic to Interval Meter Upgrade 4.Confirm Receipt of Service Order 6. Install Data Logger and/or Comms GIP Confirm Receipt of Signed Acceptance 7. Prepare & Send Meter Registration (MR) Application GIP 126 From Amend & Resubmit MR Application 13. Commission Interval Meter in Association with MDP 12. Receive tated MR Application 14. Complete & Send Meter Installation Parameter (MIP) tice 17. Update System Send Completion Advice to Retailer 16. Receive tated MIP tice GIP Receive & Validate MR Application 10. MR Application Valid? 11. Update Meter Register to Pending Interval Metering & Send tated MR Application 15. Update Meter Register to Active Interval Metering & Send tated MIP tice Doc Ref: ver 3.5 TBA Page 47 of 49

48 AEMO Distributor Retailer Customer 5.7 Diagram 106 : Downgrade from Interval to Basic Meter For tariff D Diagram 106 : Downgrade from Interval to Basic Meter For tariff D SA Process Ref: PF (B2B) MR14 1. Request Downgrade to a Basic Meter Go To Retailer identifies need for Interval to Basic Meter Downgrade Go To 103.1a From From Receive SO Completion Advice ServiceOrderResponse Go To 103.1b 4. Confirm Receipt of Service Order 5. Confirm Receipt of Signed Acceptance From Update System and set Meter to Basic 3. Distributor identifies need for Interval to Basic Meter Downgrade 6. Prepare & Send Meter Installation Parameter change tice (MIP) GIP Amend & Resubmit MIP 11. Receive tated MIP 13. Remove Data Logger and/or Comms GIP Receive & Validate MIP 9. MIP Valid? 10. Update Meter Register to Basic Metering & Send tated MIP Doc Ref: ver 3.5 TBA Page 48 of 49

49 5.8 Diagram 107: Service Order Transaction Table Diagram 107: Service Order Transaction Table #1 Service Orders Request C-K #2 Service Order Response C-K (Initial) #3 Service Order Response C-K (Final) #4 Status Change Response GIP 87 - Meter Fix Request (JEC = MFX) GIP Meter Change Request (JEC = MCH) GIP 87A - Meter Fix Request Response GIP 92 - Meter Fix Completed GIP 94 - Meter Fix tification GIP 101A - Meter Change Request Response GIP 93 - Access to Complete Meter Fix GIP Access to Complete Meter Change GIP Meter Change Completed GIP Meter Upgrade Completed GIP Meter Removal Request (JEC = MRM) GIP 151A - Meter Removal Request Response GIP Access to Complete Meter Removal GIP MIRN Status Update tification GIP Meter Removal Completed GIP Service Connection Request (JEC = SCR) GIP Service Disconnection Request (JEC = SDR) GIP Service Orders for Priority C-K (JEC = All JEC's) GIP Relocate Service Request (JEC = RSR) GIP Upgrade Service Size Request (JEC = USR) GIP Upgrade Meter Size Request (JEC = UMS) GIP 310A - Service Connection Request Response GIP 312A - Service Disconnection Request Response GIP 314A - Service Orders for Priority C-K Response GIP 316A - Relocate Service Request Response GIP 318A - Upgrade Service Size Request Response GIP 320A - Upgrade Meter Size Request Response GIP Service Connection Complete GIP Service Disconnection Complete GIP Service Orders Completed for Priority A-K GIP Relocate Service Complete GIP Upgrade Service Size Complete GIP Upgrade Meter Size Complete GIP MIRN Status Update tification JEC = Job Enquiry Doc Ref: ver 3.5 TBA Page 49 of 49

PARTICIPANT BUILD PACK 1 PROCESS FLOW DIAGRAMS VER 3.3 TABLE OF TRANSACTIONS VER 3.2 DOCUMENT REF: VERSION: 3.4 DATE: 01 JULY 2014 FINAL :

PARTICIPANT BUILD PACK 1 PROCESS FLOW DIAGRAMS VER 3.3 TABLE OF TRANSACTIONS VER 3.2 DOCUMENT REF: VERSION: 3.4 DATE: 01 JULY 2014 FINAL : PARTICIPANT BUILD PACK 1 PROCESS FLOW DIAGRAMS VER 3.3 TABLE OF TRANSACTIONS VER 3.2 PREPARED BY: DOCUMENT REF: 305196 VERSION: 3.4 MARKET DEVELOPMENT DATE: 01 JULY 2014 FINAL : Document Approval and Acceptance

More information

GAS INTERFACE PROTOCOL. PREPARED BY: AEMO DOCUMENT REF: VERSION NO: 21.0 DATE: 29 September 2017 FINAL :

GAS INTERFACE PROTOCOL. PREPARED BY: AEMO DOCUMENT REF: VERSION NO: 21.0 DATE: 29 September 2017 FINAL : PREPARED BY: AEMO DOCUMENT REF: 296630 VERSION NO: 21.0 DATE: 29 September 2017 FINAL : Version History VERSION DATE AUTHOR(S) CHANGES AND COMMENTS 8.0 01/07/2010 S. Monaco Ensure document complies with

More information

PARTICIPANT BUILD PACK 2 - GLOSSARY

PARTICIPANT BUILD PACK 2 - GLOSSARY PARTICIPANT BUILD PACK 2 - GLOSSARY PREPARED BY: MARKET DEVELOPMENT DOCUMENT REF: 305188 VERSION: 3.1 DATE: 1 JANUARY 2014 FINAL Document Approval and Acceptance AEMO Approval This document has been prepared

More information

RETAIL MARKET PROCEDURES (VICTORIA)

RETAIL MARKET PROCEDURES (VICTORIA) RETAIL MARKET PROCEDURES (VICTORIA) DOCUMENT NO: PROJECT-57-30 VERSION NO: 12.0 PROJECT-57-30 Retail Market Procedures (Victoria) Page i of 77 VERSION CONTROL VERSION NUMBER EFFECTIVE DATE PROCEDURES AFFECTED

More information

INTERVAL METER REGISTRATION PROCESS WHOLESALE GAS MARKET

INTERVAL METER REGISTRATION PROCESS WHOLESALE GAS MARKET INTERVAL METER REGISTRATION PROCESS WHOLESALE GAS MARKET PREPARED BY: Responsible Department DOCUMENT NO: 129749 VERSION NO: 5 FINAL Auslra!ion Eretgy' 111'.arket Ope

More information

MIRN STRUCTURE (VICTORIA)

MIRN STRUCTURE (VICTORIA) PREPARED BY: MARKET DEVELOPMENT DOCUMENT REF: 297179 VERSION: 2.0 DATE: 24 MAY 2010 FINAL Australian Energy Market Operator Ltd ABN 94 072 010 327 www.aemo.com.au info@aemo.com.au NEW SOUTH WALES QUEENSLAND

More information

GUIDE TO MSATS AND B2B TERMS DEFINES THE MSATS AND B2B TERMS USED IN THE ELECTRICITY RETAIL MARKET

GUIDE TO MSATS AND B2B TERMS DEFINES THE MSATS AND B2B TERMS USED IN THE ELECTRICITY RETAIL MARKET GUIDE TO MSATS AND B2B TERMS DEFINES THE MSATS AND B2B TERMS USED IN THE ELECTRICITY RETAIL MARKET Version: 1.01 Published: Friday, 16 March 2018 IMPORTANT NOTICE Purpose This Guide to MSATS and B2B Terms,

More information

RETAIL MARKET PROCEDURES (NSW AND ACT)

RETAIL MARKET PROCEDURES (NSW AND ACT) RETAIL MARKET PROCEDURES (NSW AND ACT) DOCUMENT REF: RETAILMARKET-14-4705 VERSION: 18.0 EFFECTIVE DATE: STATUS: FINAL Approved for distribution and use: APPROVED BY: Peter Geers TITLE: Executive General

More information

RETAIL MARKET PROCEDURES (NSW AND ACT)

RETAIL MARKET PROCEDURES (NSW AND ACT) RETAIL MARKET PROCEDURES (NSW AND ACT) DOCUMENT REF: RETAILMARKET-14-4705 VERSION: 15.0 EFFECTIVE DATE: STATUS: FINAL Approved for distribution and use: APPROVED BY: Matt Zema TITLE: Managing Director

More information

METERING COMPETITION EMBEDDED NETWORKS METER REPLACEMENT PROCESSES PROCEDURE CONSULTATION PARTICIPANT RESPONSE PACK. Participant: United Energy

METERING COMPETITION EMBEDDED NETWORKS METER REPLACEMENT PROCESSES PROCEDURE CONSULTATION PARTICIPANT RESPONSE PACK. Participant: United Energy UNITED ENERGY METERING COMPETITION EMBEDDED NETWORKS METER REPLACEMENT PROCESSES PROCEDURE CONSULTATION PARTICIPANT RESPONSE PACK Participant: United Energy Completion Date: 31 May 2016 3. Metrology Procedure:

More information

Electricity Distribution Network Code. made under the Electricity Act 1994

Electricity Distribution Network Code. made under the Electricity Act 1994 Electricity Distribution Network Code made under the Electricity Act 1994 CHAPTER 1: THIS CODE 4 1.1 Introduction 4 1.1.1 Code objective 4 1.1.2 Scope of the Code 4 1.1.3 Authority 4 1.1.4 Date of effect

More information

B2B PROCEDURE SERVICE ORDER PROCESS

B2B PROCEDURE SERVICE ORDER PROCESS B2B PROCEDURE SERVICE ORDER PROCESS ENERGY TYPE: Electricity PREPARED BY: Retail Markets and Metering DOCUMENT NO: Not Applicable VERSION NO: 2.2 EFFECTIVE DATE: 13 May 2015 FINAL DETERMINATION Australian

More information

NSW AND ACT GAS INTERFACE PROTOCOL. PREPARED BY: REGULATORY CHANGE VERSION NO: 6.0 DATE: 29 September 2017 FINAL

NSW AND ACT GAS INTERFACE PROTOCOL. PREPARED BY: REGULATORY CHANGE VERSION NO: 6.0 DATE: 29 September 2017 FINAL NSW AND ACT GAS INTERFACE PROTOCOL PREPARED BY: REGULATORY CHANGE VERSION NO: 6.0 DATE: 29 September 2017 FINAL Version History VERSION DATE AUTHOR(S) CHANGES AND COMMENTS 1.0 01/07/2014 D.McGowan IN003/14

More information

IMPACT IMPLEMENTATION REPORT (IIR)

IMPACT IMPLEMENTATION REPORT (IIR) IMPACT IMPLEMENTATION REPORT (IIR) Summary Section For AEMO to complete and administer. Issue Number Impacted Jurisdiction(s) Proponent Affected Gas Market(s) Industry Consultative forum(s) used Short

More information

GUIDE TO RETAIL ELECTRICITY MARKET PROCEDURES PROVIDES AN EXPLANATION OF RETAIL ELECTRICITY MARKET PROCEDURES AND SUPPORTING DOCUMENTS AS REQUIRED BY

GUIDE TO RETAIL ELECTRICITY MARKET PROCEDURES PROVIDES AN EXPLANATION OF RETAIL ELECTRICITY MARKET PROCEDURES AND SUPPORTING DOCUMENTS AS REQUIRED BY GUIDE TO RETAIL ELECTRICITY MARKET PROCEDURES PROVIDES AN EXPLANATION OF RETAIL ELECTRICITY MARKET PROCEDURES AND SUPPORTING DOCUMENTS AS REQUIRED BY CHAPTER 7 OF THE NATIONAL ELECTRICITY RULES Version:

More information

MKT IBO Training. Updated: 29 November 2016

MKT IBO Training. Updated: 29 November 2016 MKT-3193 IBO Training Updated: 29 November 2016 v About EnergyAustralia ACN has a partnership with EnergyAustralia to market competitive electricity and gas offers to residential and small business customers.

More information

Blue Telecom is compliant with the Telecommunications Consumer Protection Code (C628:2012), which applies if you meet one of the criteria below.

Blue Telecom is compliant with the Telecommunications Consumer Protection Code (C628:2012), which applies if you meet one of the criteria below. Blue Telecom Regulatory Compliance Statement Blue Telecom is compliant with the Telecommunications Consumer Protection Code (C628:2012), which applies if you meet one of the criteria below. You are an

More information

POWER OF CHOICE IMPLEMENTATION PROGRAM MARKET TRIAL TEST PLAN (VERSION 1.2)

POWER OF CHOICE IMPLEMENTATION PROGRAM MARKET TRIAL TEST PLAN (VERSION 1.2) POWER OF CHOICE IMPLEMENTATION PROGRAM MARKET TRIAL TEST PLAN (VERSION 1.2) Published: July 2017 VERSION RELEASE HISTORY Version Date Summary of Changes 0.1 25/05/2017 First draft issued for discussion

More information

MIRN STRUCTURE DOCUMENT REF: VERSION: 1.0 DATE: 8 DEC 2017 FINAL RETAILMARKET

MIRN STRUCTURE DOCUMENT REF: VERSION: 1.0 DATE: 8 DEC 2017 FINAL RETAILMARKET PREPARED BY: DOCUMENT REF: MARKETS RETAILMARKET-12-38915 VERSION: 1.0 DATE: 8 DEC 2017 FINAL Executive Summary This document describes the MIRN Structure that is used in the Victoria, Queensland, New South

More information

OVERVIEW GUIDE TO THE WESTERN AUSTRALIAN GAS RETAIL MARKET

OVERVIEW GUIDE TO THE WESTERN AUSTRALIAN GAS RETAIL MARKET OVERVIEW GUIDE TO THE WESTERN AUSTRALIAN GAS RETAIL MARKET PREPARED BY: AEMO / Markets / Market Management VERSION: 2.0 EFFECTIVE DATE: 30 April 2018 STATUS: FINAL Australian Energy Market Operator Ltd

More information

ENERGY RETAIL CODE. Version 10

ENERGY RETAIL CODE. Version 10 Version 10 May 2012 Page 2 Enquiries concerning the currency of these Guideline should be addressed to - Essential Services Commission Level 2, 35 Spring Street Melbourne Vic 3000 Telephone (03) 9651 0222

More information

GUIDE TO B2B E-HUB SELFACCREDITATION EXPLAINS HOW TO OBTAIN ACCREDITATION TO BECOME A B2B E-HUB PARTICIPANT

GUIDE TO B2B E-HUB SELFACCREDITATION EXPLAINS HOW TO OBTAIN ACCREDITATION TO BECOME A B2B E-HUB PARTICIPANT GUIDE TO B2B E-HUB SELFACCREDITATION EXPLAINS HOW TO OBTAIN ACCREDITATION TO BECOME A B2B E-HUB PARTICIPANT Version: 1.01 Published: Thursday, 7 December 2017 IMPORTANT NOTICE AEMO has prepared this Guide

More information

METERING COMPETITION EMBEDDED NETWORKS METER REPLACEMENT PROCESSES PROCEDURE CONSULTATION PARTICIPANT RESPONSE PACK. Participant: Pacific Hydro

METERING COMPETITION EMBEDDED NETWORKS METER REPLACEMENT PROCESSES PROCEDURE CONSULTATION PARTICIPANT RESPONSE PACK. Participant: Pacific Hydro METERING COMPETITION EMBEDDED NETWORKS METER REPLACEMENT PROCESSES PROCEDURE CONSULTATION PARTICIPANT RESPONSE PACK Participant: Pacific Hydro Completion Date: 31 May 2016 Table of Contents 1. Glossary

More information

Code Subsidiary Document No. 0202: Meter Read Submission: Process

Code Subsidiary Document No. 0202: Meter Read Submission: Process Code Subsidiary Document No. 0202: Table of Contents 1. Purpose and scope... 4 1.1 Purpose... 4 1.2 Scope... 4 2. Meter Read Types and Meter Read Methods... 5 2.1 Overview... 5 2.2 Meter Read Types...

More information

Travel Account Diners Club Reference Manual

Travel Account Diners Club Reference Manual Travel Account Diners Club Reference Manual Contents Introduction 3 How your account works.....4 Account Details... 5 Account Reconciler..6-7 Payment Methods and Guidelines...8-9 Accessing the Travel Account

More information

Customer Charter. Small Customer Charter. Version June Tango Energy Pty Ltd ABN

Customer Charter. Small Customer Charter. Version June Tango Energy Pty Ltd ABN Customer Charter Small Customer Charter Version 3.2 14 June 2017 Tango Energy Pty Ltd ABN 43 155 908 839 tangoenergy.com Table of Contents 1. Our commitment to you... 3 2. What s the difference between

More information

NATIONAL ELECTRICITY RULES ELECTRICITY CONNECTION FOR RETAIL CUSTOMERS CHAPTER 5A. Page 615

NATIONAL ELECTRICITY RULES ELECTRICITY CONNECTION FOR RETAIL CUSTOMERS CHAPTER 5A. Page 615 ELECTRIC ITY CONN ECTION FOR RET AIL CU STOM ERS NATIONAL ELECTRICITY RULES Page 615 Chapter 5A Electricity connection for retail customers Part A 5A.A.1 Preliminary Definitions In this Chapter: basic

More information

WA B2B Procedure. Service Order Process. STOP - You have not printed the document with "Document and Markeups".

WA B2B Procedure. Service Order Process. STOP - You have not printed the document with Document and Markeups. National Electricity Market Management Company Limited ABN 94 072 010 327 WA B2B Procedure STOP - You have not printed the document with "Document and Markeups". Version No:0. 1.4 Published: 1 Dec 20 30

More information

PURCHASING AND OUTGOING PAYMENTS PROCEDURES

PURCHASING AND OUTGOING PAYMENTS PROCEDURES PURCHASING AND OUTGOING PAYMENTS PROCEDURES PREAMBLE DEFINITIONS PART 1. DECISION TO PURCHASE 1. Application of Purchasing and Outgoing Payment Procedures 1.1. Goods and services 1.2. Payments that are

More information

This rule was approved by the Alberta Utilities Commission on January 2, 2008.

This rule was approved by the Alberta Utilities Commission on January 2, 2008. Rule 004 Alberta Tariff Billing Code Rules This rule was approved by the Alberta Utilities Commission on January 2, 2008. Contents 1 General and administrative provisions... 6 1.1 Application... 6 1.2

More information

WA B2B Procedure. Customer and Site Details Notification Process. STOP - You have not printed the document with "Document and Markeups".

WA B2B Procedure. Customer and Site Details Notification Process. STOP - You have not printed the document with Document and Markeups. National Electricity Market Management Company Limited ABN 94 072 010 327 WA B2B Procedure Customer and Site Details Notification Process STOP - You have not printed the document with "Document and Markeups".

More information

Market Opening IT Programme. Market Opening Programme. Supplier Communications Resulting from DUoS Billing & Invoicing

Market Opening IT Programme. Market Opening Programme. Supplier Communications Resulting from DUoS Billing & Invoicing Market Opening Programme Supplier Communications Resulting from DUoS Billing & Invoicing Version: 1.2 Page 1 of 47 03/12/2015 Document Updates Date Description Version 01.06.2004 Release 1 1.0 19.10.2004

More information

Nexus Requirements Clarification Log - Open Requirements

Nexus Requirements Clarification Log - Open Requirements Nexus Requirements Clarification Log - Open Requirements ID Date Raised Raised By Status Heading BRD / Topic Area Options Actions/Resolution Date Closed Section BRD Updated REQ32 19/12/2014 PN UNC Open

More information

B2B PROCEDURE CUSTOMER AND SITE DETAILS NOTIFICATION PROCESS

B2B PROCEDURE CUSTOMER AND SITE DETAILS NOTIFICATION PROCESS B2B PROCEDURE CUSTOMER AND SITE DETAILS NOTIFICATION PROCESS ENERGY TYPE: Electricity PREPARED BY: Retail Markets and Metering DOCUMENT NO: Not Applicable VERSION NO: 2.2 EFFECTIVE DATE: 13 May 2015 FINAL

More information

MIRN STRUCTURE (NSW-ACT)

MIRN STRUCTURE (NSW-ACT) PREPARED BY: RETAIL DEVELOPMENT AND CHANGE IMPLEMENTATION DOCUMENT REF: 297358 VERSION: 1.0 DATE: FINAL Executive Summary This document describes the MIRN Structure that is used in the NSW-ACT Gas

More information

Market Opening IT Programme. Market Opening Programme. Supplier Communications Resulting from DUoS Billing & Invoicing

Market Opening IT Programme. Market Opening Programme. Supplier Communications Resulting from DUoS Billing & Invoicing Market Opening Programme Supplier Communications Resulting from DUoS Billing & Invoicing Version: 1.1 Page 1 of 51 19/10/2004 Document Updates Date Description Version 01.06.2004 Release 1 1.0 19.10.2004

More information

SERVICE LEVEL PROCEDURE

SERVICE LEVEL PROCEDURE SERVICE LEVEL PROCEDURE METERING PROVIDER SERVICES PREPARED BY: AEMO MARKETS VERSION: 1.3 EFFECTIVE DATE: 01 DECEMBER 2017 STATUS: FINAL Approved for distribution and use by: APPROVED BY: PETER GEERS TITLE:

More information

The Procedure for Agreement of Change of Supplier Readings and Resolution of Disputed Change of Supplier Readings

The Procedure for Agreement of Change of Supplier Readings and Resolution of Disputed Change of Supplier Readings The Procedure for Agreement of Change of Supplier Readings and Resolution of Disputed Change of Supplier Readings MAP 08 Version : 3.2 Status : Final Date : 30 th June 2016 Document Reference : MAP08_3.2

More information

QUALIFICATION PROCEDURE

QUALIFICATION PROCEDURE METERING PROVIDERS, METERING DATA PROVIDERS & EMBEDDED NETWORK MANAGERS PREPARED BY: AEMO MARKETS VERSION: 1.2 EFFECTIVE DATE: 02 SEPTEMBER 2017 STATUS: FINAL Approved for distribution and use by: APPROVED

More information

PUBLIC SECTOR RESOURCING. Fieldglass Hiring Manager Guide. June 2018 V1.5

PUBLIC SECTOR RESOURCING. Fieldglass Hiring Manager Guide. June 2018 V1.5 Fieldglass Hiring Manager Guide June 2018 V1.5 TABLE OF CONTENTS PURPOSE....4 FIELDGLASS FAQ S...5 LOCATIONS... 5 APPROVERS... 6 COST CENTRES... 7 REQ APPROVALS... 8 FIELDGLASS SYSTEM INSTRUCTIONS...9

More information

CUSTOMER CHARTER RETAIL

CUSTOMER CHARTER RETAIL CUSTOMER CHARTER 2017 RETAIL Intoducing Tas Gas Retail Inside the Charter Welcome to Tas Gas Retail 2 About Tas Gas Retail 3 Account services 4 Sample Account 6 Service Charges 8 Disconnection & Reconnection

More information

5MS Systems Working Group

5MS Systems Working Group 5MS Systems Working Group SWG#1 - Friday, 24 August 2018 AEMO Offices: Level 9, 99 Gawler Place, Adelaide Level 10, 10 Eagle Street, Brisbane Level 22, 530 Collins Street, Melbourne Level 2, 20 Bond Street,

More information

3M Ariba Light Account Network Collaboration for Suppliers

3M Ariba Light Account Network Collaboration for Suppliers SAP Training Source To Pay 3M Ariba Light Account Network Collaboration for Suppliers External User Training Version: 1.0 Last Updated: 31-Aug-2017 3M Business Transformation & Information Technology Progress

More information

RETAILER FEED-IN TARIFF SCHEME TERMS

RETAILER FEED-IN TARIFF SCHEME TERMS RETAILER FEED-IN TARIFF SCHEME TERMS PREAMBLE Under the Electricity Act, all electricity retailers with more than 5,000 Customers must offer to purchase electricity fed back into the grid by Qualifying

More information

MINUTES Gas Retail Consultative Forum (GRCF)

MINUTES Gas Retail Consultative Forum (GRCF) MINUTES Gas Retail Consultative Forum (GRCF) MEETING : 107 DATE: Thursday 30 June 2016 TIME: 9.30 AM 12.30 PM LOCATION: s Melbourne, Sydney, Adelaide, and Teleconference. CONTACT: grcf@aemo.com.au ATTENDEES:

More information

STARHUB'S DATA PROTECTION POLICY PLEASE READ THESE TERMS CAREFULLY AS THEY MAY HAVE IMPORTANT CONSEQUENCES FOR YOU.

STARHUB'S DATA PROTECTION POLICY PLEASE READ THESE TERMS CAREFULLY AS THEY MAY HAVE IMPORTANT CONSEQUENCES FOR YOU. STARHUB'S DATA PROTECTION POLICY PLEASE READ THESE TERMS CAREFULLY AS THEY MAY HAVE IMPORTANT CONSEQUENCES FOR YOU. ABOUT THESE TERMS & CONDITIONS This is StarHub's data protection policy for all our customers

More information

RECOMMENDATION TO NAESB RGQ EXECUTIVE COMMITTEE

RECOMMENDATION TO NAESB RGQ EXECUTIVE COMMITTEE 1. Recommended Action: Effect of EC Vote to Accept Recommended Action: x Accept as requested x Change to Existing Practice Accept as modified below Status Quo Decline 2. TYPE OF MAINTENANCE Per Request:

More information

13 October 2014 Our reference: C/14/8542 OPERATING PROCEDURE COMPENSATION FOR WRONGFUL DISCONNECTION

13 October 2014 Our reference: C/14/8542 OPERATING PROCEDURE COMPENSATION FOR WRONGFUL DISCONNECTION 13 October 2014 Our reference: C/14/8542 OPERATING PROCEDURE COMPENSATION FOR WRONGFUL DISCONNECTION i TABLE OF CONTENTS 1. BACKGROUND... 1 1.1 Purpose... 1 1.2 Legislative intent and context... 1 1.3

More information

Smart Metering Infrastructure (SMI)

Smart Metering Infrastructure (SMI) Smart Metering Infrastructure (SMI) Cover Page Customer Service Functions Please note: The following methodology has been utilised to analyse the customer service functions nominated below: Function #7.6:

More information

Power of Choice Reforms

Power of Choice Reforms Power of Choice Reforms Energex Limited October 2017 Contents 1 Gentle introduction to PoC speak 2 Brief refresher on PoC reforms 2.1 PoC reforms and their meaning 2.2 What additional changes will electrical

More information

Terms of Service. Version 3.2. Zuver Pty Ltd. PO Box 119 Beaconsfield VIC

Terms of Service. Version 3.2. Zuver Pty Ltd. PO Box 119 Beaconsfield VIC Terms of Service Version 3.2 Zuver Pty Ltd PO Box 119 Beaconsfield VIC 3807 customercare@zuver.net.au www.zuver.net.au Last Updated: 29 January 2018 2018 Zuver Pty Ltd Doc Ref: ZUVER-TERMS-OF-SERVICE v3.2

More information

Ordering and Assure Guide

Ordering and Assure Guide Ordering and Assure Guide Access Products ORDERING AND ASSURE GUIDE ACCESS PRODUCTS / V7.1 / 19 APR 2012 / PAGE 1 ORDERING AND ASSURE GUIDE ACCESS PRODUCTS / V7.1 / 19 APR 2012 / PAGE 2 Document Control

More information

Business Manager. Enhancements Version January

Business Manager. Enhancements Version January Business Manager Enhancements Version 3.39 January 2019 www.farmplan.co.uk 01594 545022 support@farmplan.co.uk Contents Contents... 1 Installation Instructions... 3 Business Manager Enhancements... 4 Making

More information

Business Practice Energy Imbalance Market (EIM BP) Revision Number: Revision Date: November 30July 29, 2015

Business Practice Energy Imbalance Market (EIM BP) Revision Number: Revision Date: November 30July 29, 2015 Revision Number: 3.02.1 Revision Date: November 30July 29, 2015 Revision Log 0.0 3/31/15 Pre-market initial draft 1.0 5/15/15 Email and phone contacts, Sections 3, 7, 8, 9, 11 and Appendix A for participating

More information

There are some policy aspects which we wish to address as general observations.

There are some policy aspects which we wish to address as general observations. 26 February 2010 Manager, MCE Secretariat, Department of Resources, Energy and Tourism, GPO Box 9839 Canberra ACT 2601 MCEMarketReform@ret.gov.au Thank you for the opportunity to comment on the National

More information

Application for GS1 Malaysia Berhad Membership & LICENSE

Application for GS1 Malaysia Berhad Membership & LICENSE Application for GS1 Malaysia Berhad Membership & LICENSE GS1 Standards and Keys in Malaysia are managed by Wisma FMM, No. 3 Persiaran Dagang, Bandar Sri Damansara, 52200 Kuala Lumpur Tel: 03-62867200 Fax:

More information

Ariba Network Supplier Guide. Get Started

Ariba Network Supplier Guide. Get Started Ariba Network Supplier Guide Get Started Using This Guide The purpose of this guide is to help suppliers understand the business processes required by Constellation Brands. This button will take you back

More information

New Zealand Telecommunications Forum. Disconnection Code

New Zealand Telecommunications Forum. Disconnection Code New Zealand Telecommunications Forum Disconnection Code DOCUMENT VERSION: Number and Status: FINAL Date: September 2013 Prepared by: TCF Disconnection Code Working party Code classification Voluntary 2013

More information

FRC B2M Process Flows Sequence Diagrams

FRC B2M Process Flows Sequence Diagrams FRC B2M Flows Sequence Diagrams For the SA and WA Gas Retail Markets. Version: 3.4 Last Update : 15 August 2011 1 Disclaimer/Preamble: This document has been modified to comply as closely as possible with

More information

ASP/AML Amendment Invoice Issue Resolution - Update. 11 th June th June 2018

ASP/AML Amendment Invoice Issue Resolution - Update. 11 th June th June 2018 ASP/AML Amendment Invoice Issue Resolution - Update 11 th June 2018 11th June 2018 Agenda 1. Introduction and Summary of Issues and Challenges 2. BAU Invoicing Exclusions Defects 3. Root Cause Analysis

More information

SOIL ASSOCIATION CERTIFICATION INTERNATIONAL GROUP FOREST MANAGEMENT CERTIFICATION PROCEDURES

SOIL ASSOCIATION CERTIFICATION INTERNATIONAL GROUP FOREST MANAGEMENT CERTIFICATION PROCEDURES FSC A000525 PEFC/16-44-917 SOIL ASSOCIATION CERTIFICATION INTERNATIONAL GROUP FOREST MANAGEMENT CERTIFICATION PROCEDURES Procedures for International Group Forest Management Certification 1. Enquiry When

More information

Ariba Network Invoice Guide

Ariba Network Invoice Guide Ariba Network Invoice Guide Content Introduction Invoice Practices Before you Begin Invoicing Viewing Customer Invoice Rules Electronic Invoice Routing and notifications Account Configuration and Invoice

More information

Business processes for the Danish electricity market. (EDI guide BRS)

Business processes for the Danish electricity market. (EDI guide BRS) * Business processes for the Danish electricity market (EDI guide BRS) Wholesale model version Version 3.7 1 June 2016 'The business processes are available in Danish and English. In the event of discrepancies

More information

Victorian AMI Program Stephen Thomson, AMI Program Director Principal Consultant Marchment Hill Consulting

Victorian AMI Program Stephen Thomson, AMI Program Director Principal Consultant Marchment Hill Consulting Victorian AMI Program Stephen Thomson, AMI Program Director Principal Consultant Marchment Hill Consulting 21 January 2009 Victorian AMI Program Phases 2006 Jul 2007 May 2010 2013 Establishment Phase Involved

More information

EDF Energy Process Booklet. Everything you need to know in order to successfully sell an EDF Energy contract

EDF Energy Process Booklet. Everything you need to know in order to successfully sell an EDF Energy contract EDF Energy Process Booklet Everything you need to know in order to successfully sell an EDF Energy contract Contents Welcome page 3 Products and Pricing Page 4 Credit Policy More information for customers

More information

CBPG01. Certification Bodies. Reference Guide

CBPG01. Certification Bodies. Reference Guide CBPG01 Certification Bodies Reference Guide Version: 1.0 Date: October 2014 Table of Contents 1 Module Overview... 3 1.1 Course Objectives... 3 1.2 Understanding This Reference Guide... 3 1.3 Legend...

More information

Lycamobile Pty Ltd Customer Complaints Handling Policy Table of Contents

Lycamobile Pty Ltd Customer Complaints Handling Policy Table of Contents Lycamobile Pty Ltd Customer Complaints Handling Policy Table of Contents Introduction 1 Definition of complaint 2 Purpose of this policy 3 Our commitment to handling complaints 4 Complaints handling stages

More information

Westlink Container Park. Carrier Access Arrangements

Westlink Container Park. Carrier Access Arrangements Westlink Container Park Carrier Access Arrangements LAST UPDATED 30 MARCH 2016 1. Overview Westlink Container Park is committed to the highest principles and standards of safety, operational excellence,

More information

ONCOR INTERCONNECTION APPLICATION AND PROCESS FOR DISTRIBUTED RESOURCES

ONCOR INTERCONNECTION APPLICATION AND PROCESS FOR DISTRIBUTED RESOURCES ONCOR INTERCONNECTION APPLICATION AND PROCESS FOR DISTRIBUTED RESOURCES 2016 Commercial and Residential Solar Programs Kickoff Meeting November 11-12, 2015 Ken Brunkenhoefer Oncor Asset Planning OVERVIEW

More information

ENERGEX Inverter Energy Systems

ENERGEX Inverter Energy Systems ENERGEX Inverter Energy Systems Connecting Your Inverter Energy System to the ENERGEX Network 8181 13.08.2010 ENERGEX Limited trading as ENERGEX ABN: 40 078 849 055 http://www.energex.com.au Requests and

More information

Customer Charter: Small Customer

Customer Charter: Small Customer 1 Contents 1.Our Customer Charter...4 2. The Electricity Market...4 3. Your Contract with Us...5 4. Billing, Charges and Payment...7 5. Disconnections and Reconnections...10 6. Security Deposits...11 7.

More information

APPLICATION PACK FOR THE ECOLABEL

APPLICATION PACK FOR THE ECOLABEL APPLICATION PACK FOR THE ECOLABEL PART 1: Guidance notes ISSUED BY: Insert name of Competent Body and contact details (address, telephone and fax numbers, Email address) Date of issue: Page 1 of 12 Introduction

More information

Ontario Energy Board

Ontario Energy Board Ontario Energy Board Standard Supply Service Code for Electricity Distributors Revised (Replacing version issued on October 8, 2015) Table of Contents 1. GENERAL AND ADMINISTRATIVE PROVISIONS 1.1 PURPOSE

More information

E-CRB System specification

E-CRB System specification On behalf of Bi or Tri Borough CRB Partnerhip Appendix A E-CRB System specification July 2012 Requirement Scope Functional Requirements Validation of Application Data Processing of Applications User Administration

More information

Small Volume Wholesale Energy Agreement

Small Volume Wholesale Energy Agreement Ontario Wholesale Energy GAS & ELECTRIC Small Volume Wholesale Energy Your Information You are responsible for ensuring the accuracy of the information set out below. Reference No. 2 Bloor Street West,

More information

Schedule 2. Compendium of Gas Customer Licence Obligations. (Compendium)

Schedule 2. Compendium of Gas Customer Licence Obligations. (Compendium) Schedule 2 Compendium of Gas Customer Licence Obligations (Compendium) PART 1 PRELIMINARY... 4 1.1 Commencement of Schedule 2... 4 1.2 Interpretation of Schedule 2... 4 1.3 Definitions for Schedule 2...

More information

Your contract with us

Your contract with us Customer charter ERM Business Energy Customer Charter This Customer Charter outlines what you need to know about your rights, entitlements and obligations under your contract with ERM Power Retail Pty

More information

Service Quality and Reliability Performance Monitoring and Reporting for Owners of Electric Distribution Systems and for Gas Distributors

Service Quality and Reliability Performance Monitoring and Reporting for Owners of Electric Distribution Systems and for Gas Distributors C5-16-1 Rule 002 Service Quality and Reliability Performance Monitoring and Reporting for Owners of Electric Distribution Systems and for Gas Distributors This rule as amended was approved by the Alberta

More information

Schedule 2. Compendium of Gas Customer Licence Obligations. (Compendium)

Schedule 2. Compendium of Gas Customer Licence Obligations. (Compendium) Schedule 2 Compendium of Gas Customer Licence Obligations (Compendium) PART 1 PRELIMINARY... 4 1.1 Commencement of Schedule 2... 4 1.2 Interpretation of Schedule 2... 4 1.3 Definitions for Schedule 2...

More information

Oracle Utilities Customer Care and Billing Release Utility Reference Model Manage Field Activities and Field Orders

Oracle Utilities Customer Care and Billing Release Utility Reference Model Manage Field Activities and Field Orders Oracle Utilities Customer Care and Billing Release 2.3.1 Utility Reference Model 5.3.2.1 Manage Field Activities and Field Orders July 2012 Oracle Utilities Customer Care and Billing Utility Resource Model

More information

Frontier Telephone Companies TARIFF FCC NO. 13 Original Page 18-1 ACCESS SERVICE

Frontier Telephone Companies TARIFF FCC NO. 13 Original Page 18-1 ACCESS SERVICE Original Page 18-1 18. ADVANCED COMMUNICATIONS NETWORKS 18.1 (A) General This section contains the rules and regulations pertaining to the provision of Modem Based Data Aggregation service (Modem-Based

More information

I-SEM Programme Project Office Programme Change Control Procedure

I-SEM Programme Project Office Programme Change Control Procedure Project Office Programme Change Control Procedure Version: 1.1 FINAL Date: 8 March 2017 Document Control Production Authors Responsibility Date Jim McAllister I-SEM PMO 01/07/2015 Helen Mounsey I-SEM PMO

More information

IMPACT & IMPLEMENTATION REPORT SUMMARY SECTION (For AEMO to complete and administer) IN029/16 VIC, QLD, SA and NSW/ACT

IMPACT & IMPLEMENTATION REPORT SUMMARY SECTION (For AEMO to complete and administer) IN029/16 VIC, QLD, SA and NSW/ACT IMPACT & IMPLEMENTATION REPORT SUMMARY SECTION (For AEMO to complete and administer) Issue Number Impacted Jurisdiction (s) IN029/16 VIC, QLD, SA and NSW/ACT Proponent Danny McGowan Company AEMO Affected

More information

Container Transport Operator Access Terms & Conditions

Container Transport Operator Access Terms & Conditions ANL CONTAINER PARK Pty Ltd 11-21 Pinnacle Road Altona North VIC 3025 LAST UPDATED 28 SEPTEMBER 2016 Container Transport Operator Access Terms & Conditions 1) Overview... 2 2) Site safety requirements...

More information

Review of the General Conditions of Entitlement. Transposition table for general conditions

Review of the General Conditions of Entitlement. Transposition table for general conditions Review of the General Conditions of Entitlement Transposition table for general conditions ANNEX 17 Publication Date: 19 September 2017 Transposition table The table below shows how we have decided to

More information

What you need to do now In order to get paid in the future, you will need to submit your invoices electronically via Tungsten Network.

What you need to do now In order to get paid in the future, you will need to submit your invoices electronically via Tungsten Network. Maes-Y-Coed Road Cardiff CF14 4TT United Kingdom Dear Valued Supplier, Re: Important - From 4 th May 2015, we are no longer accepting paper invoices We are contacting you as our records indicate that you

More information

Level 2 and 3 Award and Certificate in Providing Financial Services ( )

Level 2 and 3 Award and Certificate in Providing Financial Services ( ) Level 2 and 3 Award and Certificate in Providing Financial Services (6774-02-03) Level 3-5 Units September 2014 Version 2.0 UNIT PACK Version and date Change detail Section 2.0 September 2014 Corrected

More information

PUBLIC WIFI FROM EE SOLUTION TERMS

PUBLIC WIFI FROM EE SOLUTION TERMS 1. Interpretation 1.1 The Public WiFi from EE Solution (referred to in these Solution Terms as "Public WiFi" or the "Solution") is provided in accordance with the Customer s Agreement with EE. 1.2 Solution

More information

Water NSW Reporting Manual

Water NSW Reporting Manual Water NSW Reporting Manual Operating Licence 2017-2022 Reporting Manual Water July 2017 Independent Pricing and Regulatory Tribunal of New South Wales 2017 This work is copyright. The Copyright Act 1968

More information

BB DATA SUBMISSION PROCEDURES VERSION 1.0

BB DATA SUBMISSION PROCEDURES VERSION 1.0 BB DATA SUBMISSION PROCEDURES VERSION 1.0 PREPARED BY: AEMO Markets VERSION: 1.0 EFFECTIVE DATE: 30 September 2018 STATUS: FINAL Approved for distribution and use by: APPROVED BY: Peter Geers TITLE: Executive

More information

GRAMPIANS NET SYSTEM PROFILE METHODOLOGY

GRAMPIANS NET SYSTEM PROFILE METHODOLOGY GRAMPIANS NET SYSTEM PROFILE METHODOLOGY PREPARED BY: Retail Markets and Metering VERSION: 1.0 EFFECTIVE DATE: 1 February 2013 FINAL Version Release History VERSION DATE AUTHOR COMMENTS 0.1 24 Oct 12 Justin

More information

Microsoft Cloud Service Service Description SD062 Date: November 2017

Microsoft Cloud Service Service Description SD062 Date: November 2017 Microsoft Cloud Service Service Description SD062 Date: November 2017 Microsoft Cloud Service Section 0 Table of Contents Document Control Version Completed by Date 1.0 Lance Williams 8th November 2016

More information

WP5 Supplier Capacity Market Demand Forecast

WP5 Supplier Capacity Market Demand Forecast WP5 Supplier Capacity Market Demand Forecast EMRS Working Practice Public Version: 6.0 Date: 20 April 2018 Table of Contents Change Amendment Record 3 1. Introduction 4 1.1 Scope and Purpose 4 1.2 Main

More information

disclosure statement electricity Victoria - Fair Deal 39

disclosure statement electricity Victoria - Fair Deal 39 disclosure statement electricity Victoria - Fair Deal 39 This Fair Deal 39 (Victoria) product is only available to residential customers. Eligibility criteria apply. Benefits Pay on time discount Under

More information

Billing as a service helps provide a seamless experience from invoice to payment collection.

Billing as a service helps provide a seamless experience from invoice to payment collection. UNCLASSIFIED 26/05/2016 v1.3 Cobweb Partner Service Description Billing-as-a-Service (BaaS) provides channel partners with an out-of-the-box, automated solution for effectively managing the customers billing

More information

H.E.L.P. HARVESTERS EXPRESS LEARNING PROGRAM User Guide for Harvesters Express 3.0 Ordering System

H.E.L.P. HARVESTERS EXPRESS LEARNING PROGRAM User Guide for Harvesters Express 3.0 Ordering System H.E.L.P HARVESTERS EXPRESS LEARNING PROGRAM User Guide for Harvesters Express 3.0 Ordering System A Customer Care Training Program Created For Harvesters Member Agencies Version 3.0 Issued February 5,

More information

Online Store Application Form

Online Store Application Form Online Store Application Form You need to be a Lincoln Sentry Account holder to place orders using the online store website. Please provide your existing Lincoln Sentry account number. Submit the completed

More information

PRODUCT DISCLOSURE STATEMENT FOR THE THIRSTY CAMEL CARD

PRODUCT DISCLOSURE STATEMENT FOR THE THIRSTY CAMEL CARD PRODUCT DISCLOSURE STATEMENT FOR THE THIRSTY CAMEL CARD Issued by LiquorSmart Pty Ltd (ABN 45 089 797 491) of 8/161 Ward Street, North Adelaide SA 5006 trading as Thirsty Camel Effective Date 1 st May

More information