á671ñ CONTAINERS PERFORMANCE TESTING

Size: px
Start display at page:

Download "á671ñ CONTAINERS PERFORMANCE TESTING"

Transcription

1 USP 40 Physical Tests / á671ñ Containers Performance Testing 1 á671ñ CONTAINERS PERFORMANCE TESTING INTRODUCTION It is the purpose of this chapter to provide standards for the functional properties of packaging systems used for solid oral dosage forms (SODF) and liquid oral dosage forms (LODF) for pharmaceuticals and dietary supplements. Definitions that apply to this chapter are provided in Packaging and Storage Requirements á659ñ. The tests that follow are provided to determine the moisture vapor transmission rate (water vapor permeation rate) and spectral transmission of plastic containers. Test methods are provided to measure moisture vapor transmission rates that may be useful for pharmaceutical and dietary supplement manufacturers to determine the level of barrier protection provided by packaging systems for SODF. Additional methods are provided to determine classification of packaging systems for SODF and LODF that are repackaged by organizations or when being dispensed on prescription by pharmacists as single-unit and multiple-unit containers (Table 1). There may be additional packaging systems where the test methods in this section could be applied; however, any deviation should be described. If other methods are used to measure moisture vapor transmission rate, these methods should be described in sufficient detail to justify their use. Section Title Application Users Change to read: Table 1. Moisture Vapor Transmission Test Methods for Packaging Systems Barrier Protection Determination Multiple-unit containers with seal intact or broached state and single-unit or unit dose containers Manufacturers Solid Oral Dosage Forms Classification for Multiple- Unit Containers Multiple-unit containers with closure applied and seal intact or broached state Manufacturers Packagers Repackagers Pharmacies Classification for Single-Unit Containers and Unit-Dose Containers Single-unit and unit-dose containers in sealed state Manufacturers Packagers Repackagers Pharmacies MOISTURE VAPOR TRANSMISSION Liquid Oral Dosage Forms Classification for Multiple- Unit Containers and Unit- Dose Containers Multiple- and single-unit containers Manufacturers Packagers Repackagers Pharmacies Barrier Protection Determination for Packaging Systems for Solid Oral Dosage Forms This section describes moisture vapor transmission test methods for multiple-unit containers (Method 1), high barrier singleunit and unit-dose containers (Method 2), and low barrier single-unit and unit-dose containers (Method 3) used by pharmaceutical manufacturers to package SODF. The purpose of this test method is to obtain reliable and specific moisture vapor transmission rates that can be used to discriminate among barrier performance of packaging systems used for regulated articles; the method is based upon ASTM method D This method contains the following attributes: a. Reports a specific moisture vapor transmission value for a container rather than a classification b. Provides sufficient sensitivity and precision to allow differentiation among moisture barrier performance for containers c. Conditions used for testing these packaging systems are the same as those used for accelerated stability testing of the primary packaging of regulated articles (typically 40 /75% RH). EQUIPMENT The following items should be available: A balance for weighing the test specimens that has sufficient capacity to weigh the test specimens throughout the period of the test (see Weighing on an Analytical Balance á1251ñ). The balance shall have sensitivity adequate to measure small differences in weight from one time point to the next. The weighing uncertainty shall be smaller than 5% of the weight gain from one time point to the next. The weighing uncertainty is typically three times the balance resolution/sensitivity. As an example, a balance with a resolution of 0.1 mg is acceptable for packaging systems whose weight gain per time interval is more than or equal to 6 mg [(0.1 3)/5%], which is 60 times the balance sensitivity. A chamber capable of maintaining 40 ± 2 and 75 ± 5% RH. 1 ASTM D7709. Standard Test Methods for Measuring Water Vapor Transmission Rate (WVTR) of Pharmaceutical Bottles and Blisters published by ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA

2 2 á671ñ Containers Performance Testing / Physical Tests USP 40 DESICCANT Method 1: The desiccant is anhydrous calcium chloride in granular form. Other desiccants, such as a molecular sieve or silica gel, may be suitable. If anhydrous calcium chloride is used, pre-dry at 215 ± 5 for 7 1 /4 ± 1 /4 h to ensure that any hexahydrate present is fully converted to the anhydrate. Cool the desiccant in a desiccator for at least 2 h before use. Methods 2 and 3: The desiccant is silica gel molded in a form to fit the size and shape of the blister cavity used. Other desiccants may be suitable, for example, a molecular sieve. If silica gel is used, pre-dry in a circulating hot air oven at one of two conditions: 155 ± 5 for 3 1 /4 ± 1 /4 h or 150 ± 5 for 4 1 /4 ± 1 /4 h. If a molecular sieve is used, pre-dry in a muffle furnace at 595 ± 25. Dry the 4A and 3A sieves for 3 1 /4 ± 1 /4 h; dry the 13X sieve for 5 1 /4 ± 1 /4 h. Cool the desiccant in a desiccator for at least 2 h before use. [NOTE It has been shown 2 that anhydrous calcium chloride may contain calcium hexahydrate, which loses water only when the temperature reaches 200.] PROCEDURE Method 1: Use 15 multiple-unit containers and 15 closures representative of the system to be tested. Prepare the test specimens by filling each multiple-unit container two-thirds with desiccant then, for screw type closures, apply the closure using the torque that is within the range of tightness specified in Table 2. For other closure types, apply according to the intended method. Ensure that a proper seal has been made with the intended membrane to the land area of the bottle finish. Identify each multiple-unit container with indelible ink. Do not use a label. If there is a need to increase the precision of the method, the user can test the system without the closure as long as an impervious seal remains on the container. If desired, weigh each multiple-unit container at ambient temperature and RH. Record this weight for time zero, but do not use it in the calculation of permeation. Place all containers in the test chamber (40 /75% RH) within 1 h of weighing. Weigh all multiple-unit containers at time intervals of 7 days ± 1 h. Weigh the multiple-unit containers at 7, 14, 21, 28, and 35 days to get steady-state data points. (The time interval from time 0 to day 7 is the period of equilibration.) Prior to weighing at each time interval, equilibrate the containers for about 30 min at the weighing temperature and RH. Limit the time out of the chamber to less than 2 h. Record the weights in an appropriate manner for later computation of the regression line. Closure Diameter a (mm) Table 2. Torque Applicable to Screw-Type Container Suggested Tightness Range with Manually Applied Torque b (inch-pounds) Suggested Tightness Range with Manually Applied Torque b (Newton-meters) a The torque designated for the next larger closure diameter is to be applied in testing containers having a closure diameter intermediate to the diameters listed. b A suitable apparatus is available from SecurePak, PO Box 905, Maumee, Ohio ; MRA Model with indicators on both the removal and application sides available in the following ranges: 1) 0 25 inch lbs., read in 1-inch lb. increments, 2) 0 50 inch lbs., read in 2-inch lb. increments, and 3) inch lbs., read in 5-inch lb. increments. For further detail regarding instructions, reference may be made to Standard Test Method for Application and Removal Torque of Threaded or Lug-Style Closures ASTM Method D3198, published by the ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA Determination of water vapor transmission rate (WVTR) of HDPE bottles for pharmaceutical products. Chen, Yisheng and Yanxia Li, International Journal of Pharmaceutics, 358 (2008)

3 USP 40 Physical Tests / á671ñ Containers Performance Testing 3 Closure Diameter a (mm) Table 2. Torque Applicable to Screw-Type Container (Continued) Suggested Tightness Range with Manually Applied Torque b (inch-pounds) Suggested Tightness Range with Manually Applied Torque b (Newton-meters) a The torque designated for the next larger closure diameter is to be applied in testing containers having a closure diameter intermediate to the diameters listed. b A suitable apparatus is available from SecurePak, PO Box 905, Maumee, Ohio ; MRA Model with indicators on both the removal and application sides available in the following ranges: 1) 0 25 inch lbs., read in 1-inch lb. increments, 2) 0 50 inch lbs., read in 2-inch lb. increments, and 3) inch lbs., read in 5-inch lb. increments. For further detail regarding instructions, reference may be made to Standard Test Method for Application and Removal Torque of Threaded or Lug-Style Closures ASTM Method D3198, published by the ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA Method 2: Use 10 test units for this method. Provide a minimum of 10 blister cavities for each test unit. If the card contains less than 10 cavities, bundle the cards to form a single test unit of at least 10 cavities. This is required to provide sufficient weight gain at each time interval. Fill with pre-dried desiccant, and seal the blisters on equipment that is capable of correctly filling and sealing the blister. The desiccant should fill the cavity. The total weight of desiccant shall be sufficient to meet the quantity required to avoid partial saturation of the desiccant before completion of the test. Fill the blisters in a low-humidity atmosphere (as low as possible, but not greater than 50% RH). Do not expose the desiccants to room humidity for more than 30 min before sealing. Identify each test specimen with indelible ink; do not use a label. A test unit will be one or more test specimens. Bundle test speciments into test units. Weigh each test unit at ambient temperature and RH. Record this weight for time zero. Place all test units in the test chamber (40 /75% RH) within 1 h of weighing. Weigh all test units at time intervals of 7 days ±1 h. Weigh the test units at 7, 14, 21, 28, and 35 days to get 5 steady-state data points. (The time interval from time 0 to day 7 is the period of equilibration.) Prior to weighing at each time interval, equilibrate the containers for 30 ± 5 min at the controlled weighing temperature and RH. Limit the time out of the chamber to less than 2 h. Record the weights in an appropriate manner for later computation of the regression line. Ultra-high barrier blisters may not show the full measure of precision and sensitivity this method can provide. For ultra-high barrier blisters, test units should have more than 10 cavities, but NMT 30 cavities. Examples are foil-foil blisters or very small blisters formed from other materials. An alternative approach is to double or triple the length of weighing intervals to achieve at least a 6-mg weight gain per time interval by the test specimen. Method 3: Prepare the test units as directed for Method 2. Place all test units in the test chamber (40 /75% RH) within 1 h of weighing. Weigh the test units at the end of 2 days (48 ± 1 h). At this time, the difference in weight (the weight gain) is divided by the number of blisters and days (2) in each test unit and this is taken as the moisture vapor transmission rate in mg/ blister/day. The number of blisters tested depends on the barrier characteristics of the material, the size of the blister, and the sensitivity of the balance used in the test. For this method, the requirement of five consecutive weighings is waived because the desiccant quickly becomes saturated when packed in a low-barrier package and stored at 40 /75% RH. [NOTEFor singleunit and unit-dose low barrier containers, the weight gain after the second day displays a curvilinear profile typical of approaching saturation of the desiccant. To obtain five weighings within 2 days is not viable and is likely to increase variability. Methods 2 and 3 may require that the blister cards be bundled in multiples to achieve periodic weight gains of sufficient magnitude to use the balance sensitivity. When bundled, these cards or test specimens are called test units. The weight gain in each weighing period shall be 20 times the sensitivity of the balance, and the balance sensitivity is 3 times the balance precision. In other words, the minimal weight gain per time interval should be at least 60 times the balance precision.] CALCULATIONS For Methods 1 and 2, perform the regression analysis for each test unit. Typically, the initial data point (at day 0) is not included in fitting the regression line. The slope of the regression line is the moisture vapor transmission rate of each test unit. For Method 1, the slope is the moisture vapor transmission rate for the corresponding multiple-unit container. For Method 2, the moisture vapor transmission rate of each blister cavity is calculated by dividing the slope by the number of cavities in each test unit. For Method 3, calculate the weight gain in mg/day from day 0 to day 2 using the 10 test units. The moisture vapor transmission rate of each blister is calculated by dividing the weight gain by 2 (for 2 days) and the number of blisters in each test unit. Regression Equation: W = I + MT

4 4 á671ñ Containers Performance Testing / Physical Tests USP 40 Calculations: Intercept (I) = W MT where M = regression line slope N = number of data points (each point consists of a weight and a time) W = measured weight W = overall weight mean T = time point T = overall time point mean I = regression line intercept (point where regression line intersects the vertical axis) equals sum of cross-products (for example, for each of the N data points, subtract the overall weight mean from the weight value and the overall time mean from the time value and multiply the two differences to get a cross-product. Then sum all N cross-products). equals sum of squared deviations (for example, for each of the N data points, subtract the overall mean time from the time value and square the difference. Then sum all N squared differences). RESULTS Method 1: Report the moisture vapor transmission rate as the average value, in mg/day per container, and the standard deviation of the 15 slopes. Properly describe the container closure system tested. Method 2: Report the moisture vapor transmission rate as the average value, in mg/day per cavity, and the standard deviation of the 10 test unit slopes. Properly describe the container closure system tested. Method 3: Report the moisture vapor transmission rate as the average value from day 0 to day 2, in mg/day per blister, and the standard deviation of the 10 test unit slopes. Properly describe the container closure system tested. Packaging System Classification for Multiple-Unit Containers for Solid Oral Dosage Forms The following procedure and classification scheme is provided to evaluate the moisture vapor transmission characteristics of multiple-unit containers. The information gathered should be used to make an informed judgment regarding the suitability of the packaging system for SODF. DESICCANT Place a quantity of 4- to 8-mesh, anhydrous calcium chloride 3 in a shallow container, taking care to exclude any fine powder, dry at 110 for 1 h, and cool in a desiccator. PROCEDURE Select 12 containers of a uniform size and type, clean the sealing surfaces with a lint-free cloth, and close and open each container 30 times. Apply the closure firmly and uniformly each time the container is closed. Close screw-capped containers with a torque that is within the range of tightness specified in Table 2. Add Desiccant to 10 of the containers, designated test containers, filling each to within 13 mm of the closure if the container volume is 20 ml or more, or filling each to two-thirds of capacity if the container volume is less than 20 ml. If the interior of the container is more than 63 mm in depth, an inert filler or spacer may be placed in the bottom to minimize the total weight of the container and Desiccant; the layer of Desiccant in such a container shall be not less than 5 cm in depth. Close each container immediately after adding Desiccant, applying the 3 Suitable 4- to 8-mesh, anhydrous calcium chloride is available commercially as Item JT from VWR International ( telephone ).

5 USP 40 Physical Tests / á671ñ Containers Performance Testing 5 torque designated in Table 2 when closing screw-capped containers. To each of the remaining two containers, designated controls, add a sufficient number of glass beads to attain a weight approximately equal to that of each of the test containers, and close, applying the torque designated in Table 2 when closing screw-capped containers. Record the weight of the individual containers to the nearest 0.1 mg if the container volume is less than 20 ml; to the nearest mg if the container volume is 20 ml or more but less than 200 ml; or to the nearest centigram (10 mg) if the container volume is 200 ml or more; and store at 75 ± 3% RH and a temperature of 23 ± 2. [NOTE A saturated system of 35 g of sodium chloride with each 100 ml of water placed in the bottom of a desiccator maintains the specified humidity. Other methods may be employed to maintain these conditions.] After 336 ± 1 h (14 days), record the weight of the individual containers in the same manner. Completely fill five empty containers of the same size and type as the containers under test with water or a noncompressible, free-flowing solid, such as well-tamped fine glass beads, to the level indicated by the closure surface when in place. Transfer the contents of each to a graduated cylinder, and determine the average container volume, in ml. Calculate the rate of moisture vapor transmission, in mg/day/l: (1000/14V)[(T F T I ) (C F C I )] V = volume of the container (ml) T F = final weight of each test container (mg) T i = initial weight of each test container (mg) C F = average final weight of the two controls (mg) C i = average initial weight of the two controls (mg) Classification: Packaging systems are tight if NMT 1 of the 10 test containers exceeds 100 mg/day/l in moisture vapor transmission, and none exceeds 200 mg/day/l. Packaging systems are well-closed if NMT 1 of the 10 test containers exceeds 2000 mg/day/l in moisture vapor transmission, and none exceeds 3000 mg/day/l. POLYETHYLENE AND POLYPROPYLENE CONTAINERS Fit the containers with impervious seals obtained by heat-sealing the bottles with an aluminum foil polyethylene laminate or other suitable seal. 4 Test as directed in the Procedure section. Classification: High-density polyethylene containers meet the requirements if the moisture vapor transmission exceeds 10 mg/day/l in NMT 1 of the 10 test containers and exceeds 25 mg/day/l in none of them. Low-density polyethylene containers meet the requirements if the moisture vapor transmission exceeds 20 mg/day/l in NMT 1 of the 10 test containers and exceeds 30 mg/day /L in none of them. Polypropylene containers meet the requirements if the moisture vapor transmission exceeds 15 mg/day/l in NMT 1 of the 10 test containers and exceeds 25 mg/day/l in none of them. Packaging System Classification for Single-Unit Containers and Unit-Dose Containers for Solid Oral Dosage Forms The following procedure and classification scheme are provided to evaluate the moisture vapor transmission characteristics of single-unit containers and unit-dose containers. The information gathered should be used to make an informed judgment regarding the suitability of the packaging system for SODF. DESICCANT Dry suitable desiccant pellets 5 at 110 for 1 h prior to use, and cool in a desiccator. Use pellets weighing approximately 400 mg each and having a diameter of approximately 8 mm. [NOTE If necessary because of limited unit-dose container size, pellets weighing less than 400 mg each and having a diameter of less than 8 mm may be used.] PROCEDURE Method 1: Seal NLT 10 unit-dose containers with one pellet in each, and seal 10 additional, empty unit-dose containers to provide the controls, using finger cots or padded forceps to handle the sealed containers. Number the containers, and record the individual weights 6 to the nearest mg. Weigh the controls as a unit, and divide the total weight by the number of controls to obtain the average. Store all of the containers at 75 ± 3% RH and at a temperature of 23 ± 2. [NOTE A saturated 4 A suitable laminate for sealing has, as the container layer, polyethylene of NLT mm (0.001 in) and a second layer of aluminum foil of NLT mm ( in), with additional layers of suitable backing materials. A suitable seal can also be obtained by using glass plates and a sealing wax consisting of 60% of refined amorphous wax and 40% of refined crystalline paraffin wax. 5 Suitable moisture-indicating desiccant pellets are available commercially from sources such as Unit Dose Supply, P.O. Box 104, Ringoes, NJ ( telephone ), as Indicating Desiccant Pellets, Item No. TK Accurate comparisons of Class A containers may require test periods in excess of 28 days if weighings are performed on a Class A prescription balance (see Prescription Balances and Volumetric Apparatus Used in Compounding á1176ñ (CN 1-May-2017) ). The use of an analytical balance on which weights can be recorded to 4 or 5 decimal places may permit more precise characterization between containers and/or shorter test periods.

6 6 á671ñ Containers Performance Testing / Physical Tests USP 40 system of 35 g of sodium chloride with each 100 ml of water placed in the bottom of a desiccator maintains the specified humidity. Other methods may be employed to maintain these conditions.] After a 24-h interval, and at each multiple thereof (see Classification), remove the containers from the chamber, and allow them to equilibrate for 15 to 60 min in the weighing area. Again, record the weight of the individual containers and the combined controls in the same manner. [NOTE If any indicating pellets turn pink during this procedure, or if the pellet weight increase exceeds 10%, terminate the test, and regard only earlier determinations as valid.] Return the containers to the humidity chamber. Calculate, to two significant figures, the rate of moisture vapor transmission, in mg/day, of each container taken: (1/N)[(W F W I ) (C F C I )] N = number of days expired in the test period (beginning after the initial 24-h equilibration period) W F = final weight of each test container (mg) W i = initial weight of each test container (mg) C F = average final weight of the controls (mg) C i = average inital weight of the controls (mg) [NOTE Where the moisture vapor transmission rates measured are less than 5 mg/day, and where the controls are observed to reach equilibrium within 7 days, the individual moisture vapor transmission rates may be determined more accurately by using the 7-day test container and control container weights as W I and C I, respectively, in the calculation. In this case, a suitable test interval for Class A (see Classification) would be NLT 28 days following the initial 7-day equilibration period (a total of 35 days).] Method 2: Use this procedure for packs (e.g., punch-out cards) that incorporate a number of separately sealed unit-dose containers or blisters. Seal a sufficient number of packs, such that NLT four packs and a total of NLT 10 unit-dose containers or blisters filled with one pellet in each unit are tested. Seal a corresponding number of empty packs, each pack containing the same number of unit-dose containers or blisters as used in the test packs, to provide the controls. Store all of the containers at 75 ± 3% RH and at a temperature of 23 ± 2. [NOTE A saturated system of 35 g of sodium chloride with each 100 ml of water placed in the bottom of a desiccator maintains the specified humidity. Other methods may be employed to maintain these conditions.] After 24 h, and at each multiple thereof (see Classification), remove the packs from the chamber, and allow them to equilibrate for about 45 min. Record the weights of the individual packs, and return them to the chamber. Weigh the control packs as a unit, and divide the total weight by the number of control packs to obtain the average empty pack weight. [NOTE If any indicating pellets turn pink during the procedure, or if the average pellet weight increase in any pack exceeds 10%, terminate the test, and regard only earlier determinations as valid.] Calculate, to two significant figures, the average rate of moisture vapor transmission, in mg/day, for each unit-dose container or blister in each pack taken: [1/(N X)][(W F W I ) (C F C I )] N = number of days expired in the test period (beginning after the initial 24-h equilibration period) X = number of separately sealed units per pack W F = final weight of each test pack (mg) W i = initial weight of each test pack (mg) C F = final weight of the control packs (mg) C i = initial weight of the control packs (mg Using the Desiccant stated for Method 1 and Method 2, the test and control containers or packs are weighed after every 24 h and after suitable test intervals for the final weighings. W F and C F, are as follows: 24 h for Class D; 48 h for Class C; 7 days for Class B; and NLT 28 days for Class A. Classification: The individual unit-dose containers as tested in Method 1 are designated as follows: Class A if not more than 1 of 10 containers tested exceeds 0.5 mg/day in moisture vapor transmission rate and none exceeds 1 mg/day; Class B if NMT 1 of 10 containers tested exceeds 5 mg/day and none exceeds 10 mg/day; Class C if NMT 1 of 10 containers tested exceeds 20 mg/day and none exceeds 40 mg/day; and Class D if the containers tested meet none of the moisture vapor transmission rate requirements. The packs as tested in Method 2 are designated as follows: Class A if no pack tested exceeds 0.5 mg/day in average blister moisture vapor transmission rate; Class B if no pack tested exceeds 5 mg/day in average blister moisture vapor transmission rate; Class C if no pack tested exceeds 20 mg/day in average blister moisture vapor transmission rate; and Class D if the packs tested meet none of the above average blister moisture vapor transmission rate requirements. Packaging System Classification for Multiple-Unit Containers and Unit-Dose Containers for Liquid Oral Dosage Forms The following procedure and classification scheme are provided to evaluate the moisture vapor transmission characteristics of multiple-unit containers. The information gathered should be used to make an informed judgment regarding the suitability of the packaging system for LODF. [NOTE Determine the weights of individual container closure systems (bottle, inner seal, if used, and closure) both as tare weights and fill weights, to the nearest 0.1 mg if the bottle capacity is less than 200 ml; to the

7 USP 40 Physical Tests / á671ñ Containers Performance Testing 7 nearest mg if the bottle capacity is 200 ml or more but less than 1000 ml; or to the nearest centigram (10 mg) if the bottle capacity is 1000 ml or more.] PROCEDURE Select 12 bottles of a uniform size and type, and clean the sealing surfaces with a lint-free cloth. Fit each bottle with a seal, closure liner (if applicable), and closure. Number each container closure system, and record the tare weight. Remove the closures and, using a pipet, fill 10 bottles with water to the fill capacity. Fill two containers with glass beads, to the same weight as the filled test containers. If using screw closures, apply a torque that is within the range specified in Table 2, and store the sealed containers at a temperature of 25 ± 2 and a relative humidity of 40 ± 2%. After 336 ± 1 h (14 days), record the weight of the individual containers, and calculate the water weight loss rate, in percent per year, for each bottle taken: [(W 1i W T ) (W 14i W T ) (W C1 W C14 )] /(W 1i W T ) 14 W 1i = initial weight of each individual bottle (i) W T = tare weight W 14i = weight of each individual bottle (i) at 14 days W C1 = initial weight of the control container at day 1 W C14 = weight of the control container at 14 days (ERR 1-Apr-2016) CLASSIFICATION The packaging system meets the requirements for tight if the percentage of water weight loss does not exceed 2.5% per year in NMT 1 of the 10 test containers and does not exceed 5.0% per year in any of them. SPECTRAL TRANSMISSION Apparatus 7 Use a spectrophotometer of suitable sensitivity and accuracy, adapted for measuring the amount of light transmitted by plastic materials used for pharmaceutical containers. In addition, the spectrophotometer is capable of measuring and recording light transmitted in diffused as well as parallel rays. Procedure Select sections to represent the average wall thickness. Cut circular sections from two or more areas of the container, and trim them as necessary to give segments of a size convenient for mounting in the spectrophotometer. After cutting, wash and dry each specimen, taking care to avoid scratching the surfaces. If the specimen is too small to cover the opening in the specimen holder, mask the uncovered portion of the opening with opaque paper or masking tape, provided that the length of the specimen is greater than that of the slit in the spectrophotometer. Immediately before mounting in the specimen holder, wipe the specimen with lens tissue. Mount the specimen with the aid of a tacky wax, or by other convenient means, taking care to avoid leaving fingerprints or other marks on the surfaces through which light must pass. Place the section in the spectrophotometer with its cylindrical axis parallel to the plane of the slit and approximately centered with respect to the slit. When properly placed, the light beam is normal to the surface of the section, and reflection losses are at a minimum. Continuously measure the transmittance of the section with reference to air in the spectral region of interest with a recording instrument or at intervals of about 20 nm with a manual instrument, in the region of nm. Limits The observed spectral transmission does not exceed the limits given in Table 3 for containers intended for parenteral use. The observed spectral transmission for plastic containers for products intended for oral or topical administration does not exceed 10% at any wavelength in the range nm. 7 For further details regarding apparatus and procedures, reference may be made to the following publications of ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA : Standard Test Method of Test for Haze and Luminous Transmittance of Transparent Plastics, ASTM Method D e1; Standard Practice for Computing the Colors of Objects by Using the CIE System, ASTM Method E

8 8 á671ñ Containers Performance Testing / Physical Tests USP 40 Nominal Size (in ml) Table 3. Limits for Plastic Classes I to VI Maximum Percentage of Spectral Transmission at Any Wavelength between 290 and 450 nm [NOTE Any container of a size intermediate to those listed above exhibits a spectral transmission not greater than that of the next larger size container listed in Table 3. For containers larger than 50 ml, the limits for 50 ml apply.] GLOSSARY Blister: Formed, lidded, and sealed plastic or foil dome that contains the capsule or tablet (usually a single-unit or unitdose). Low-barrier blister: Blisters made from low-barrier materials formed and sealed so that the moisture vapor transmission rate when tested at 40 /75% relative humidity (RH) is greater than 1.0 mg/cavity-day. High-barrier blister: Blisters made from high-barrier material, formed and sealed so that the moisture vapor transmission rate when tested at 40 /75% RH is less than 1.0 mg/cavity-day. Ultra-high barrier blister: Blisters made from ultlra high-barrier material, formed and sealed so that the moisture vapor transmission rate when tested at 40 /75% RH is less than 0.01 mg/cavity-day. Blister card: A contiguous group of blisters formed and sealed with lid in place. The number of blisters per card commonly ranges from one to ten but may be more. The blister card may sometimes be referred to as a packaging system. Cavity: Formed, lidded, and sealed plastic or foil dome (see Blister). Moisture vapor transmission rate: The steady state moisture vapor transmission in unit time through a packaging system, under specific conditions of temperature and humidity. These test methods use gravimetric measurement to determine the rate of weight gain as a result of water vapor transmission into the packaging system and subsequent uptake by a desiccant enclosed within the packaging system. Test specimen (or specimen): For multiple-unit containers, the bottle is the test specimen; and for single-unit or unitdose containers, the blister card containing multiple blister cavities is the test specimen. For blisters, more than one card (or specimen) may be grouped into a test unit for conducting the test. Test unit: For multiple-unit containers, the bottle is the test unit as well as being the test specimen and for single-unit or unit-dose containers, the test unit is a group of test specimens (blister cards) processed together for temperature and humidity exposure and for weighing at each time point. The purpose of the test unit for single-unit or unit-dose containers is to gain the advantage of additive weight gain resulting from more blister cavities than are present on a single card. The test unit, when applied to bottles, is used to maintain congruence of naming among the three test methods.

á660ñ CONTAINERS GLASS

á660ñ CONTAINERS GLASS USP 40 Physical Tests / á660ñ Containers Glass 1 á660ñ CONTAINERS GLASS DESCRIPTION Glass containers for pharmaceutical use are intended to come into direct contact with pharmaceutical products. Glass

More information

GUIDELINE FOR THE STABILITY TESTING

GUIDELINE FOR THE STABILITY TESTING 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 GUIDELINE FOR THE STABILITY TESTING OF NON-PRESCRIPTION (OTC)

More information

METHOD 5A - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM THE ASPHALT PROCESSING AND ASPHALT ROOFING INDUSTRY

METHOD 5A - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM THE ASPHALT PROCESSING AND ASPHALT ROOFING INDUSTRY 446 METHOD 5A - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM THE ASPHALT PROCESSING AND ASPHALT ROOFING INDUSTRY NOTE: This method does not include all of the specifications (e.g., equipment and

More information

Standard Test Method for Measuring Compressive Properties of Thermal Insulations 1

Standard Test Method for Measuring Compressive Properties of Thermal Insulations 1 Designation: C 165 95 Standard Test Method for Measuring Compressive Properties of Thermal Insulations 1 This standard is issued under the fixed designation C 165; the number immediately following the

More information

Caffeine 100 mg, Scopolamine Hydrobromide 0.5 mg Oral Rapid-Dissolve Tablets (Solid Suspension, 96 x 750 mg [0.93 ml] Tablets)

Caffeine 100 mg, Scopolamine Hydrobromide 0.5 mg Oral Rapid-Dissolve Tablets (Solid Suspension, 96 x 750 mg [0.93 ml] Tablets) 4/19/2015; Page 1 SUGGESTED FORMULATION Ingredient Listing Qty. Unit NDC # Supplier Caffeine (Anhydrous), USP 9.600 g Scopolamine Hydrobromide, USP 0.050 g Mango Flavor (Powder) 0.75 g Raspberry Flavor

More information

Standard Test Method for Index of Aggregate Particle Shape and Texture 1

Standard Test Method for Index of Aggregate Particle Shape and Texture 1 Designation: D 98 00 Standard Test Method for Index of Aggregate Particle Shape and Texture This standard is issued under the fixed designation D 98; the number immediately following the designation indicates

More information

Standard Specification for Pigments for Integrally Colored Concrete 1

Standard Specification for Pigments for Integrally Colored Concrete 1 Designation: C 979 99 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 1948 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Specification

More information

Standard Test Procedures Manual

Standard Test Procedures Manual STP 205-5 Standard Test Procedures Manual 1. SCOPE 1.1. Description of Test 1.2. Application of Test This method describes the procedure for determining the relationship between the moisture content and

More information

Tex-113-E, Laboratory Compaction Characteristics and Moisture- Density Relationship of Base Materials

Tex-113-E, Laboratory Compaction Characteristics and Moisture- Density Relationship of Base Materials Characteristics and Moisture- Density Overview Effective Date: August 1999 October 2004. This method determines the relationship between water content and the dry unit mass (density) of base materials.

More information

Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete 1

Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete 1 Designation: C 1604/C 1604M 05 Standard Test Method for Obtaining and Testing Drilled Cores of Shotcrete 1 This standard is issued under the fixed designation C 1604/C 1604M; the number immediately following

More information

TESTS ON AGGREGATES 58

TESTS ON AGGREGATES 58 TESTS ON AGGREGATES 58 59 3.1 DETERMINATION OF INDICES (FLAKINESS AND ELONGATION) STANDARD IS: 2386 (Part 1) 1963. DEFINITION The Flakiness Index of aggregates is the percentage by weight of particles

More information

Standard Test Methods for Rubber Property Compression Set 1

Standard Test Methods for Rubber Property Compression Set 1 Designation: D 395 03 Standard Test Methods for Rubber Property Compression Set 1 This standard is issued under the fixed designation D 395; the number immediately following the designation indicates the

More information

METHOD OF TEST FOR FREEZING-AND-THAWING OF COARSE AGGREGATE

METHOD OF TEST FOR FREEZING-AND-THAWING OF COARSE AGGREGATE Ministry of Transportation, Ontario Test Method LS-614, Rev. No. 17 Laboratory Testing Manual Date : 97 08 01 Page 1 of 8 METHOD OF TEST FOR FREEZING-AND-THAWING OF COARSE AGGREGATE 1. SCOPE 1.1 This method

More information

Blank Oral Rapid-Dissolve Tablets (Solid Suspension, 96 x 750 mg [0.93 ml] Tablets) Ingredient Listing Qty. Unit NDC # Supplier. 0.

Blank Oral Rapid-Dissolve Tablets (Solid Suspension, 96 x 750 mg [0.93 ml] Tablets) Ingredient Listing Qty. Unit NDC # Supplier. 0. 4/19/2015; Page 1 SUGGESTED FORMULATION APIs* Ingredient Listing Qty. Unit NDC # Supplier Orange Flavor (Powder) 0.40 g Stevia Powder (Stevioside) 0.20 g Bitterness Reducing Agent (NF01) Natural (Powder)**

More information

Dry matter content and fibre content

Dry matter content and fibre content Revised 1996 Black liquor Dry matter content and fibre content 0 Introduction This SCAN-test Standard replaces SCAN-N 22:77 from which it differs in that it also provides a procedure for the determination

More information

Highway Engineering Materials - CE 400 Spring 2009 Aggregate Labs Draft Due February 4, 2009 Final Report Due February 11, 2009

Highway Engineering Materials - CE 400 Spring 2009 Aggregate Labs Draft Due February 4, 2009 Final Report Due February 11, 2009 Highway Engineering Materials - CE 400 Spring 2009 Aggregate Labs Draft Due February 4, 2009 Final Report Due February 11, 2009 January 21 st and January 28 th, 2009 T1) ASTM D4791-95: Flat and Elongated

More information

Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry 1

Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry 1 Designation: 98 Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry 1 This standard is issued under the fixed designation ; the number immediately following

More information

CORESTA Recommended Method No. 57

CORESTA Recommended Method No. 57 Cooperation Centre for Scientific Research Relative to Tobacco Tobacco and Tobacco Products Analytes Sub-Group CORESTA Recommended Method No. 57 DETERMINATION OF WATER IN TOBACCO AND TOBACCO PRODUCTS BY

More information

LABORATORY COMPACTION CHARACTERISTICS AND MOISTURE-DENSITY RELATIONSHIP OF SUBGRADE, EMBANKMENT SOILS, AND BACKFILL MATERIAL

LABORATORY COMPACTION CHARACTERISTICS AND MOISTURE-DENSITY RELATIONSHIP OF SUBGRADE, EMBANKMENT SOILS, AND BACKFILL MATERIAL Test Procedure for LABORATORY COMPACTION CHARACTERISTICS AND MOISTURE-DENSITY RELATIONSHIP OF SUBGRADE, EMBANKMENT SOILS, AND BACKFILL MATERIAL Texas Department of Transportation TxDOT Designation: Tex-114-E

More information

Tryptophan 200 mg Oral Rapid-Dissolve Tablets (Solid Suspension, mg [0.93 ml] Tablets) Ingredient Listing Qty. Unit NDC # Supplier. 0.

Tryptophan 200 mg Oral Rapid-Dissolve Tablets (Solid Suspension, mg [0.93 ml] Tablets) Ingredient Listing Qty. Unit NDC # Supplier. 0. 11/23/2015; Page 1 SUGGESTED FORMULATION Ingredient Listing Qty. Unit NDC # Supplier Tryptophan, USP 19.200 g Raspberry Flavor (Powder) 0.50 g Stevia Powder (Stevioside) 0.20 g Bitterness Reducing Agent

More information

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell Hardness, Total DOC316.53.01045 Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method 8374 4 to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell Scope and application: For boiler and ultrapure

More information

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters.

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters. Iron, Ferrous DOC316.53.01049 1,10-Phenanthroline Method 1 Method 8146 0.02 to 3.00 mg/l Fe 2+ Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater, seawater, brine solutions,

More information

ABAA Light density open cell semi rigid spray polyurethane foam Material Specification

ABAA Light density open cell semi rigid spray polyurethane foam Material Specification Light density open cell semirigid spray polyurethane foam Material Specification 1. Scope This document specifies the material property requirements for open cell sprayapplied semirigid polyurethane foam,

More information

PHARMACEUTICAL PRINCIPLES OF SOLID DOSAGE FORMS

PHARMACEUTICAL PRINCIPLES OF SOLID DOSAGE FORMS PHARMACEUTICAL PRINCIPLES OF SOLID DOSAGE FORMS J. T. Carstensen, Ph.D. Professor of Pharmacy University of Wisconsin Madison, Wisconsin TECHNOMIC ^PUBLISHING CO.. INC J 1.ANCASTER BASET, TABLE OF CONTENTS

More information

Standard Test Method for Adhesion Between Steel Tire Cords and Rubber 1

Standard Test Method for Adhesion Between Steel Tire Cords and Rubber 1 Designation: D 2229 02 Standard Test Method for Adhesion Between Steel Tire Cords and Rubber 1 This standard is issued under the fixed designation D 2229; the number immediately following the designation

More information

Standard Test Methods for Transmitted Shock Characteristics of Foam-in-Place Cushioning Materials 1

Standard Test Methods for Transmitted Shock Characteristics of Foam-in-Place Cushioning Materials 1 Designation: D 4168 95 (Reapproved 00) Standard Test Methods for Transmitted Shock Characteristics of Foam-in-Place Cushioning Materials 1 This standard is issued under the fixed designation D 4168; the

More information

Laboratory Manual. Concrete and aggregate. Content

Laboratory Manual. Concrete and aggregate. Content Laboratory Manual Concrete and aggregate Content Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 Section 9 Trial Mix Slump Density of Compacted Fresh Concrete Making of

More information

CRD-C Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforced Steel

CRD-C Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforced Steel Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforced Steel 1. Scope 1.1 This test method covers comparison of concretes on the basis of the bond developed with

More information

Designation: D 2412 02 (Reapproved 2008) An American National Standard Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading 1 This standard

More information

EMBANKMENT AND BASE WAQTC FOP AASHTO T 99 / T 180 (18) IN-PLACE DENSITY

EMBANKMENT AND BASE WAQTC FOP AASHTO T 99 / T 180 (18) IN-PLACE DENSITY MOISTURE-DENSITY RELATIONS OF SOILS: USING A 2.5 kg (5.5 lb) RAMMER AND A 305 mm (12 in.) DROP FOP FOR AASHTO T 99 USING A 4.54 kg (10 lb) RAMMER AND A 457 mm (18 in.) DROP FOP FOR AASHTO T 180 Scope This

More information

TEST PROCEDURE SUMMARY

TEST PROCEDURE SUMMARY TEST PROCEDURE SUMMARY 1. Compressive Strength - ASTM D695 The compressive strength of a product is determined by subjecting a solid cylinder of material whose length is equal to twice its diameter to

More information

Testosterone 20 mg Oral Rapid-Dissolve Tablets (Solid Suspension, 96 x 750 mg [0.93 ml] Tablets) Ingredient Listing Qty. Unit NDC # Supplier

Testosterone 20 mg Oral Rapid-Dissolve Tablets (Solid Suspension, 96 x 750 mg [0.93 ml] Tablets) Ingredient Listing Qty. Unit NDC # Supplier 4/16/2015; Page 1 SUGGESTED FORMULATION Ingredient Listing Qty. Unit NDC # Supplier Testosterone (Micronized), USP 1.920 g Orange Flavor (Powder) 0.40 g Vanillin Flavor (Powder) 0.20 g Stevia Powder (Stevioside)

More information

BULK SPECIFIC GRAVITY OF COMPACTED HOT MIX ASPHALT (HMA) USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 (11)

BULK SPECIFIC GRAVITY OF COMPACTED HOT MIX ASPHALT (HMA) USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 (11) BULK SPECIFIC GRAVITY OF COMPACTED HOT MIX ASPHALT (HMA) USING SATURATED SURFACE-DRY SPECIMENS FOP FOR AASHTO T 166 (11) Scope This procedure covers the determination of bulk specific gravity (G mb ) of

More information

MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS

MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS This amendment forms a part of, dated 30 June 1970, and is approved for use by all Departments and Agencies

More information

MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS

MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS MILITARY SPECIFICATION CHEMICAL CONVERSION MATERIALS FOR COATING ALUMINUM AND ALUMINUM ALLOYS This amendment forms a part of MIL-C-81706, dated 30 June 1970, and is approved for use by all Departments

More information

Designation: D 2122 98 (Reapproved 2004) An American National Standard Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings 1 This standard is issued under the fixed designation

More information

Drying of Concrete TDS 183

Drying of Concrete TDS 183 Drying of Concrete TDS 183 As the occurrence of fast track construction continues to rise, the need to install a finished floor on a wet concrete slab is typically far too soon for the floor covering.

More information

Feasibility of integral water repellent admixtures in low pressure compatible injected fill grouts

Feasibility of integral water repellent admixtures in low pressure compatible injected fill grouts Structural Repairs and Maintenance of Heritage Architecture XII 659 Feasibility of integral water repellent admixtures in low pressure compatible injected fill grouts C. Citto, A. E. Geister & D. W. Harvey

More information

[Amdt , 60 FR 50336, Sept. 28, 1995; 60 FR 54409, Oct. 23, 1995, as amended at 69 FR 3696, Jan. 26, 2004; 70 FR 56099, Sept.

[Amdt , 60 FR 50336, Sept. 28, 1995; 60 FR 54409, Oct. 23, 1995, as amended at 69 FR 3696, Jan. 26, 2004; 70 FR 56099, Sept. Subpart K Specifications for Packagings for Class 7 (Radioactive) Materials 178.350 Specification 7A; general packaging, Type A. (a) Each packaging must meet all applicable requirements of subpart B of

More information

Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications 1

Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications 1 Designation: C1265 94 (Reapproved 2005) 1 Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications 1 This standard is issued under

More information

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DENSITY (UNIT WEIGHT) AND VOLUME OF CONCRETE

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DENSITY (UNIT WEIGHT) AND VOLUME OF CONCRETE State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DENSITY (UNIT WEIGHT) AND VOLUME OF CONCRETE SCOPE This test method describes the procedure for determining the density

More information

A modified cup-method for lightweight and highly permeable materials.

A modified cup-method for lightweight and highly permeable materials. A modified cup-method for lightweight and highly permeable materials. K. Svennberg Building Physics, Lund University, Sweden L. Wadsö Building Materials, Lund University, Sweden ABSTRACT: With an increasing

More information

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL Before installation these instructions must be fully read and understood 3600B 3650B DISCLAIMER OF WARRANTIES The contract between Varec Vapor Control Inc. and our customer states Varec Vapor Control Inc.

More information

Standard Test Method for Expansion Index of Soils 1

Standard Test Method for Expansion Index of Soils 1 This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because it may not be technically

More information

Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for Commonwealth of Pennsylvania PA Test Method No.705 Department of Transportation 17 Pages LABORATORY TESTING SECTION Method of Test for MARSHALL CRITERIA FOR COMPACTED BITUMINOUS SPECIMENS 1. SCOPE 1.1

More information

European Aviation Safety Agency. European Technical Standard Order. ETSO-C80 Date : Subject: FLEXIBLE FUEL AND OIL CELL MATERIAL

European Aviation Safety Agency. European Technical Standard Order. ETSO-C80 Date : Subject: FLEXIBLE FUEL AND OIL CELL MATERIAL European Aviation Safety Agency ETSOC80 Date : 24.10.03 European Technical Standard Order Subject: FLEIBLE FUEL AND OIL CELL MATERIAL 1 Applicability This ETSO gives the requirements that flexible fuel

More information

OHD L-54 STANDARD METHOD OF TEST FOR MAKING, CURING, AND TESTING CEMENT-TREATED BASE FIELD SAMPLES

OHD L-54 STANDARD METHOD OF TEST FOR MAKING, CURING, AND TESTING CEMENT-TREATED BASE FIELD SAMPLES STANDARD METHOD OF TEST FOR MAKING, CURING, AND TESTING CEMENT-TREATED BASE FIELD SAMPLES Oklahoma D.O.T. Page 1 of 7 1 SCOPE 1.1 This method covers procedures for making, curing, and testing cylindrical

More information

6. PREPARATION OF LABORATORY-MIXED, LABORATORY-COMPACTED SPECIMENS

6. PREPARATION OF LABORATORY-MIXED, LABORATORY-COMPACTED SPECIMENS 5. APPARATUS 5.1. Equipment for preparing and compacting specimens from 1 of the following: T 167, T 245, T 247, T 312 or ASTM D 3387... 5.2. Equipment for determining the theoretical maximum specific

More information

ASTM E96 VS. F1249 WHICH PROVIDES MORE ACCURATE TEST RESULTS?

ASTM E96 VS. F1249 WHICH PROVIDES MORE ACCURATE TEST RESULTS? ASTM E96 VS. F1249 WHICH PROVIDES MORE ACCURATE TEST RESULTS? Modern barriers require more sensitive and accurate test methods. Does E96 stand up to the test? MOCON, Inc. May 16, 2017 Contents Abstract

More information

Tex-121-E, Soil-Lime Testing

Tex-121-E, Soil-Lime Testing Overview Effective dates: August 1999 - July 2002. This method consists of two parts. 'Part I, Compressive Strength Test Methods (Laboratory Mixed)' determines the unconfined compressive strength as an

More information

Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1

Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1 Designation: D 1754 97 Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1 This standard is issued under the fixed designation D 1754; the number immediately

More information

Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics 1

Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics 1 Designation: D 623 03 Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics This standard is issued under the fixed designation D 623; the number immediately following

More information

Development of standard laboratory based test to measure compost stability Annex A

Development of standard laboratory based test to measure compost stability Annex A Creating markets for recycled resources Development of standard laboratory based test to measure compost stability Annex A Research Report: Organics Project Code: ORG0020 Written by: R H Llewelyn. Direct

More information

MAKING, CURING AND TESTING CEMENT TREATED AND UNBOUND BASES (Kansas Test Method KT-37)

MAKING, CURING AND TESTING CEMENT TREATED AND UNBOUND BASES (Kansas Test Method KT-37) 5.9.37 MAKING, CURING AND TESTING CEMENT TREATED AND UNBOUND BASES (Kansas Test Method ) 1. SCOPE This method covers the procedure for making and curing compression test specimens of Cement Treated and

More information

Questa Rock Pile Stability Study SOP 54v5 Page 1 DRAFT STANDARD OPERATING PROCEDURE NO. 54 ATTERBERG LIMITS REVISION LOG

Questa Rock Pile Stability Study SOP 54v5 Page 1 DRAFT STANDARD OPERATING PROCEDURE NO. 54 ATTERBERG LIMITS REVISION LOG Questa Rock Pile Stability Study SOP 54v5 Page 1 DRAFT STANDARD OPERATING PROCEDURE NO. 54 ATTERBERG LIMITS REVISION LOG Revision Number Description Date 54 Original SOP written by LFG 6/04/04 54.1 Revisions

More information

Standard Test Method for Rapid Determination of Percent Compaction 1

Standard Test Method for Rapid Determination of Percent Compaction 1 Designation: D 5080 00 Standard Test Method for Rapid Determination of Percent Compaction 1 This standard is issued under the fixed designation D 5080; the number immediately following the designation

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-26763-6 ASTM D1739:1998 SOUTH AFRICAN NATIONAL STANDARD Standard test method for collection and measurement of dustfall (settleable particulate matter) This national standard is the identical

More information

Standard Test Methods for Flexible Cellular Materials Made From Olefin Polymers 1

Standard Test Methods for Flexible Cellular Materials Made From Olefin Polymers 1 Designation: D 3575 00 e1 Standard Test Methods for Flexible Cellular Materials Made From Olefin Polymers 1 This standard is issued under the fixed designation D 3575; the number immediately following

More information

WHO GUIDELINE Stability testing of active pharmaceutical ingredients and finished pharmaceutical products

WHO GUIDELINE Stability testing of active pharmaceutical ingredients and finished pharmaceutical products WHO GUIDELINE Stability testing of active pharmaceutical ingredients and finished pharmaceutical products 1. Introduction 1.1 Objectives of these guidelines 1.2 Scope of these guidelines 1.3 General principles

More information

Standard Test Method of Measuring Shrinkage from Mold Dimensions of Thermoplastics 1

Standard Test Method of Measuring Shrinkage from Mold Dimensions of Thermoplastics 1 Designation: D 955 00 Standard Test Method of Measuring Shrinkage from Mold Dimensions of Thermoplastics 1 This standard is issued under the fixed designation D 955; the number immediately following the

More information

Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method 1

Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method 1 Designation: D 2290 00 e1 An American National Standard Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method 1 This standard is issued under

More information

BRIEFING. PF 44(4) [July Aug. 2018]. The General Chapters Packaging and. Distribution Expert Committee has canceled the PF 44(4) proposal and is

BRIEFING. PF 44(4) [July Aug. 2018]. The General Chapters Packaging and. Distribution Expert Committee has canceled the PF 44(4) proposal and is BRIEFING 659 Packaging and Storage Requirements, USP 42 page 6801 and PF 44(4) [July Aug. 2018]. The General Chapters Packaging and Distribution Expert Committee has canceled the PF 44(4) proposal and

More information

BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE

BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE Test Procedure for BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE Texas Department of Transportation TxDOT Designation: Tex-201-F Effective Dates: November 2004 December 2010. 1. SCOPE 1.1 This

More information

Ingredient Listing Qty. Unit NDC # Supplier. Sterile Preparation

Ingredient Listing Qty. Unit NDC # Supplier. Sterile Preparation 9/7/2016; Page 1 SUGGESTED FORMULATION Ingredient Listing Qty. Unit NDC # Supplier CollaSil OSA 18.000 g Mango Flavor (Powder) 0.90 g Raspberry Flavor (Powder) 0.48 g Vanillin Flavor (Powder) 0.24 g Stevia

More information

Commonwealth of Pennsylvania PA Test Method No. 715 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Commonwealth of Pennsylvania PA Test Method No. 715 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for Commonwealth of Pennsylvania PA Test Method No. 715 Department of Transportation 5 Pages LABORATORY TESTING SECTION Method of Test for DETERMINATION OF BULK SPECIFIC GRAVITY OF COMPACTED BITUMINOUS MIXTURES

More information

Standard Test Method for Determining Compressive Resistance of Shipping Containers, Components, and Unit Loads 1

Standard Test Method for Determining Compressive Resistance of Shipping Containers, Components, and Unit Loads 1 Designation: D 642 00 (Reapproved 2005) Standard Test Method for Determining Compressive Resistance of Shipping Containers, Components, and Unit Loads 1 This standard is issued under the fixed designation

More information

Standard Test Method for Commercial Mass of a Shipment of Yarn or Manufactured Staple Fiber or Tow 1

Standard Test Method for Commercial Mass of a Shipment of Yarn or Manufactured Staple Fiber or Tow 1 Designation: D 2494 02 Standard Test Method for Commercial Mass of a Shipment of Yarn or Manufactured Staple Fiber or Tow 1 This standard is issued under the fixed designation D 2494; the number immediately

More information

Which silica gel is best for which humidity range?

Which silica gel is best for which humidity range? product information 2017 + Art Sorb + Silica gel E PRO SORB is a silica gel ideally suited for stabilizing relative humidity (RH) inside museum display cases and storage cabinets. Thanks to its large inner

More information

Standard Test Methods for Wetting and Drying Compacted Soil-Cement Mixtures 1

Standard Test Methods for Wetting and Drying Compacted Soil-Cement Mixtures 1 Designation: D 559 96 AMERICAN SOCIETY FOR TESTING AND MATERIALS 00 Barr Harbor Dr., West Conshohocken, PA 9428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Test Methods for

More information

Scope. Overview. Apparatus. FOP for AASHTO T 255. FOP for AASHTO T 265. Total Evaporable Moisture Content of Aggregate by Drying

Scope. Overview. Apparatus. FOP for AASHTO T 255. FOP for AASHTO T 265. Total Evaporable Moisture Content of Aggregate by Drying FOP for AASHTO T 255 Total Evaporable Moisture Content of Aggregate by Drying FOP for AASHTO T 265 Scope Overview This procedure covers the determination of moisture content of aggregate and soil in accordance

More information

Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks 1

Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks 1 Designation: C 1393 00 Standard Specification for Perpendicularly Oriented Mineral Fiber Roll and Sheet Thermal Insulation for Pipes and Tanks 1 This standard is issued under the fixed designation C 1393;

More information

TEST PLAN. Constant Head Saturated Hydraulic Conductivity Measurements on Repacked Core Samples

TEST PLAN. Constant Head Saturated Hydraulic Conductivity Measurements on Repacked Core Samples NYE COUNTY NUCLEAR WASTE REPOSITORY PROJECT OFFICE TEST PLAN TITLE: Constant Head Saturated Hydraulic Conductivity Measurements on Repacked Core Samples REVISION: 0 DATE: 4-1-04 PAGE: 1 of 8 TEST PLAN

More information

An investigation of the water vapour resistance

An investigation of the water vapour resistance An investigation of the water vapour resistance - the humidity detection sensor method in Versmaperm MkIV compared to the gravimetric method Master s Thesis in Applied Physics FRIDA BÖRJESSON Department

More information

Concrete Field Testing Technician Study Guide

Concrete Field Testing Technician Study Guide Concrete Field Testing Technician Study Guide ASTM C 172 SAMPLING FRESH CONCRETE 1. The maximum allowable time between obtaining the first and final portions of a composite sample is minutes. (Section

More information

Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation 1

Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation 1 Designation: C 578 95 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation 1 This standard is issued under the fixed designation C 578; the number immediately following the designation

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1122 DETERMINING SULFATE CONTENT IN SOILS. July 17, 2015

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1122 DETERMINING SULFATE CONTENT IN SOILS. July 17, 2015 STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1122 DETERMINING SULFATE CONTENT IN SOILS 1122.01 Scope 1122.02 Definitions 1122.03 Equipment 1122.04 Procedure 1122.05 Report July 17, 2015 1122.01

More information

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL Before installation these instructions must be fully read and understood 2010B 3500B 2020B The VAREC Vapor Control Inc. 2010B/2020B/3500B Series pressure and/or vacuum relief valves have not been tested

More information

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS) TESTING APPLICATION STANDARD (TAS) 135-95 STANDARD REQUIREMENTS FOR FIBERGLASS REINFORCED TILE, SHINGLES OR PANELS AND FIBER CEMENT SHINGLES, SHAKES OR PANELS 1. Scope: 1.1 This Protocol covers physical

More information

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD Method 8000 DR/4000 PROCEDURE Reactor Digestion Method* (0 to 40.0** mg/l COD) Scope and Application: For water, wastewater and seawater; digestion is required. The estimated detection limit for program

More information

Bulk Density Protocol

Bulk Density Protocol Bulk Density Protocol Purpose To measure the bulk density of each horizon in a soil profile Overview In the field, students collect three soil samples from each horizon in a soil profile using a container

More information

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right , 8374 Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method ULR (4 to 1000 µg/l Ca and Mg as CaCO 3 ) Scope and Application: For boiler and ultra pure water. DOC316.53.01045 Method 8374 Pour-Thru

More information

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS Revision index Effective date B 15/02/2015 ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS 4, avenue du Recteur-Poincaré, 75782 Paris Cedex 16 Tel. 33 (0)1.64.68.84.97 Fax. 33 (0)1.64.68.83.45

More information

Four Ways Ketoprix Polyketone can Improve Gear Performance

Four Ways Ketoprix Polyketone can Improve Gear Performance Superior Creep Rupture Performance Quieter Operation Four Ways Ketoprix Polyketone can Improve Gear Performance Engineers have been using thermoplastic resins to produce gears used in assemblies for the

More information

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting. Sulfate DOC316.53.01473 USEPA 1 SulfaVer 4 Method 2 Method 8051 2 to 70 mg/l SO 4 2 Powder Pillows Scope and application: For water, wastewater and seawater. 1 USEPA accepted for reporting wastewater analyses.

More information

Standard Test Method for Determining the Chemical Resistance of Fiberglass- Reinforced Thermosetting Resins by One-Side Panel Exposure 1,2

Standard Test Method for Determining the Chemical Resistance of Fiberglass- Reinforced Thermosetting Resins by One-Side Panel Exposure 1,2 Designation: D 398 02 An American National Standard Standard Test Method for Determining the Chemical Resistance of Fiberglass- Reinforced Thermosetting Resins by One-Side Panel Exposure 1,2 This standard

More information

ANNEX V ASEAN GUIDELINES ON STABILITY STUDY AND SHELF-LIFE OF HEALTH SUPPLEMENTS

ANNEX V ASEAN GUIDELINES ON STABILITY STUDY AND SHELF-LIFE OF HEALTH SUPPLEMENTS Association of South East Asian Nations (ASEAN) ANNEX V ASEAN GUIDELINES ON STABILITY STUDY AND SHELF-LIFE OF HEALTH SUPPLEMENTS Disclaimer: This document is provided for information purpose only and subject

More information

Glass & Plastic Containers

Glass & Plastic Containers CONTAINER GUIDE Container Guide Glass & Plastic Containers Glass Bottles DWK offers over 3,000 containers and closures from borosilicate to soda-lime glass. Each container has an assortment of caps and

More information

Concrete Strength Testing Technician Study Guide

Concrete Strength Testing Technician Study Guide Concrete Strength Testing Technician Study Guide ASTM C 617 CAPPING CYLINDRICAL CONCRETE SPECIMENS 1. Neat cement caps and high-strength gypsum-plaster shall be formed against a glass plate at least in.

More information

COMMERCIAL ITEM DESCRIPTION TAPE, TWO SIDE PRESSURE SENSITIVE ADHESIVE, FLEXIBLE FOAM BASE (FOR USE WITH EXPLOSIVES)

COMMERCIAL ITEM DESCRIPTION TAPE, TWO SIDE PRESSURE SENSITIVE ADHESIVE, FLEXIBLE FOAM BASE (FOR USE WITH EXPLOSIVES) [INCH-POUND] September 29, 1998 SUPERSEDING MIL-T-60394A(AR) 24 Jul 1967 COMMERCIAL ITEM DESCRIPTION TAPE, TWO SIDE PRESSURE SENSITIVE ADHESIVE, FLEXIBLE FOAM BASE (FOR USE WITH EXPLOSIVES) The General

More information

Standard Test Procedures Manual

Standard Test Procedures Manual STP 208-3 Standard Test Procedures Manual 1. SCOPE 1.1. Description of Test This method describes the procedure for determining the relationship between the moisture content and density for soil cement

More information

Standard Practice for Sampling and the Amount of Testing of Hydraulic Cement 1

Standard Practice for Sampling and the Amount of Testing of Hydraulic Cement 1 Designation: C 183 02 Standard Practice for Sampling and the Amount of Testing of Hydraulic Cement 1 This standard is issued under the fixed designation C 183; the number immediately following the designation

More information

EXPERIMENT 3 SOLIDS DETERMINATION

EXPERIMENT 3 SOLIDS DETERMINATION EXPERIMENT 3 SOIDS DETERMINATION A. PURPOSE To familiarize the students with various analytical operations such as weighing, filtration, evaporation and combustion which are commonly encountered in gravimetric

More information

Standard Test Method for Foaming Agents for Use in Producing Cellular Concrete Using Preformed Foam 1

Standard Test Method for Foaming Agents for Use in Producing Cellular Concrete Using Preformed Foam 1 Designation: C 796 04 Standard Test Method for Foaming Agents for Use in Producing Cellular Concrete Using Preformed Foam 1 This standard is issued under the fixed designation C 796; the number immediately

More information

Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation 7 Pages 1. SCOPE LABORATORY TESTING SECTION Method of Test for THE MOISTURE-DENSITY RELATIONS OF SOILS (Using a 2.5 kg (5.5-lb.)

More information

VICH Topic GL26 BIOLOGICALS: TESTING OF RESIDUAL MOISTURE

VICH Topic GL26 BIOLOGICALS: TESTING OF RESIDUAL MOISTURE The European Agency for the Evaluation of Medicinal Products Veterinary Medicines and Inspections CVMP/VICH/096/01-Final London, 30 April 2002 VICH Topic GL26 Step 7 BIOLOGICALS: TESTING OF RESIDUAL MOISTURE

More information

4.4 MICROBIOLOGICAL METHOD FOR THE ESTIMATION OF. The microbiological assay was performed by using the test

4.4 MICROBIOLOGICAL METHOD FOR THE ESTIMATION OF. The microbiological assay was performed by using the test 109 4.4 MICROBIOLOGICAL METHOD FOR THE ESTIMATION OF AMOXICILLIN The microbiological assay was performed by using the test organism Staphylococcus aureus. The strain was isolated from soil and allowed

More information

Evaluation Methods of Concrete Carbonation Suppressive Performance of Surface Coating

Evaluation Methods of Concrete Carbonation Suppressive Performance of Surface Coating Evaluation Methods of Concrete Carbonation Suppressive Performance of Surface Coating Kenji Motohashi Shibaura Institute of Technology, Japan Toyosu 3-7-, Koto-Ku, 13-848 Japan, motoken@shibaura-it.ac.jp

More information

Technical Bulletin. For Foam Plastic Insulation, Extrusion Matters Performance Equals Resisting Water XPS Performs Better Than EPS.

Technical Bulletin. For Foam Plastic Insulation, Extrusion Matters Performance Equals Resisting Water XPS Performs Better Than EPS. Polystyrene Insulation Types There are two types of rigid polystyrene foam plastic insulation, extruded (XPS), and expanded (EPS). XPS is manufactured in a continuous extrusion process that produces a

More information

1. Payment for concrete sidewalks is on square foot basis. a. Limits for measurement for trench excavation as follows:

1. Payment for concrete sidewalks is on square foot basis. a. Limits for measurement for trench excavation as follows: Section 02775 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Reinforced concrete sidewalks. B. Wheelchair ramps. C. Reinforced slope paving. 1.02 MEASUREMENT AND PAYMENT A. Unit Prices. 1. Payment for concrete

More information

Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation Revised May Pages LABORATORY TESTING SECTION

Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation Revised May Pages LABORATORY TESTING SECTION Commonwealth of Pennsylvania PA Test Method No. 106 Department of Transportation Revised 7 Pages 1. SCOPE LABORATORY TESTING SECTION Method of Test for THE MOISTURE-DENSITY RELATIONS OF SOILS (Using a

More information