2 Introduction The Effects of Temperature Cycling on Cheddar Cheese Thermal storage is a technique commonly used for shifting electrical demand. Thermal storage involves storing available heating or cooling energy in a storage medium during peak use hours and using this stored energy during peak hours to reduce or even eliminate electric loads during that period. This strategy can be used to reduce the cost of operating the refrigeration system in a warehouse. This project investigated the possible use of cheese as a thermal storage medium in refrigerated warehouses. Cheese is stored in refrigerated warehouses during the aging process that develops the taste and texture of the cheese. Cheese is typically aged for 60 days or more in warehouses containing several million pounds of cheese. Thermal modeling was performed by Zehr (1997) to estimate the technical and economic potential for thermal storage in a cheddar cheese warehouse. Zehr s study concluded that the potential demand and cost savings were substantial but the analysis did not explore the possible effects that temperature variation may have on the quality of the cheese. The experiment described in this report was designed to produce the most extreme temperature variations predicted for thermal storage to determine the effect of these on the aging process of cheddar cheese. In this report, the model used to determine the temperature response of cheese in a temperature-cycled warehouse is described first. Then the experiments conducted on stored cheese blocks are described. Finally, the results of an evaluation of the cheese exposed to temperature cycling are presented. Lumped Capacitance Model of Warehouse air Temperature A finite difference model was developed by Zehr to predict warehouse temperatures and estimate the electrical power consumption for various thermal storage scenarios. The model parameters were based on an actual cheddar cheese warehouse in Marshfield, Wisconsin. This model was used to specify the parameters used in the temperature cycling experiment described in this report. The lumped capacitance model simulates heat transfer between three masses: the new cheese brought into the warehouse; the cheese already stored in the warehouse; and the air inside the warehouse. In addition, the model accounts for cooling loads due to lighting, motors and other equipment, as well as infiltration of the outside air. The values for these loads were provided by Zehr. A conventional cheese warehouse is maintained at F for 24 hours per day. In the thermal storage scenario, the refrigeration system is operated to maintain air temperature at 30 F for twelve hours each day. During the other twelve on peak hours, the refrigeration system is shut off. This situation was modeled and the resulting air 2

3 temperature determined from the heat transfer model. During the off period, the temperature is in the range of F. Pallets of cheese enter the warehouse at a uniform temperature of F from the production line. In the model, the mass of the previously stored cheese was taken to be 2.8 million lb., the annual average mass of cheese in storage in the Zehr model. The heat transfer coefficients were provided by Zehr. Thermal conductivity of the cheese (both new and stored) was set at Btu/ (hr-ft2-f), and the effective convection coefficient between the cheese and air was set at Btu/ (hr-ft-f). (The effective convection coefficient accounts for the thermal resistance of the cheese when a model for average temperature is used.) The following management conditions were chosen as a worst-case scenario: 1. the outside ambient temperature was set at 92 F; 2. the cheese entered the warehouse at 97 F 3. an entire daily production (156,000 lb.) was inserted into the warehouse instantaneously, rather than on an incremental basis; and 4. The new cheese was placed in the warehouse at the beginning of the twelvehour period when the coolers were off. Simulations indicated that the temperature of the warehouse rises quickly from 30 F to approximately 46 F within two hours after the refrigeration system is shut off. Thereafter, the temperature rises slowly, and at the end of the twelve-hour period, the air temperature climbs to 48.3 F. (See Figure 1.). Based on the simulations, the temperature of the experimental chamber was thus held at 30 F for 12 hours and 48 F for the other 12 hours of the day. 3

4 Figure 1. Results of Warehouse Model. Warehouse Simulation Temperature (F) Bulk Cheese New Palette Warehouse Air Time (hrs) Finite Element Model of the Temperature Profiles in a Block of Cheese The warehouse model describes the average cheese temperature. A detailed finite element model was developed to estimate the temperature variations inside a 40-lb. block of cheddar cheese exposed to the experimental air temperature variations. Because of symmetry, only one quarter of the block of cheese needed to be considered. This portion of the block was then simulated as 16 nodes of equal size. Each node was assumed to be at a constant temperature. Zehr s value of thermal conductivity of cheese was used. The results of the simulation are given in Figure 2. The locations of the temperature nodes are described in Figure 4. A convection coefficient that included free convection and radiation relations was used to determine transfer between the block and the air. The value of this coefficient was 2.3 Btu/(hr-ft-F). The thermal resistance of the cardboard was assessed using a conductivity of 0.04 Btu/ (hr-ft2-f) and a thickness of 0.25 inches. The bottom of the box was assumed to be adiabatic. A one-day simulation using the values given earlier is shown in Figure 2. 4

5 Figure 2. Internal Cheese Temperature Finite Model Element Results. Simulation 50 Temperature (F) W arehouse Air Center of Block Corner of Block Time (hrs) The lower air temperature limit (30 F) was chosen to avoid the possibility of freezing the outside layers of cheese. The upper air temperature (48 F) was chosen to avoid the conventional accepted abuse temperature of stored cheese (50 F). The average cheese temperature (38 F) was thus somewhat below typical cheese storage temperature (40 45 F). Experimental Apparatus The effect of temperature variation on cheese quality was evaluated on two 40-lb. blocks of cheddar cheese. These blocks of cheese were obtained from a local cheese plant, transported in an insulated container to the UW and placed in the experimental chamber within 2 hours of production. The internal cheese temperature and air temperature in the experimental were monitored with a Campbell 21X Data logger which also controlled the air temperature in the chamber. The experimental chamber was a refrigerator fitted with 150-Watt strip heater and a fan was used to circulate air in the chamber. The blocks of cheese were placed one atop the other, which allowed for equal surface area for each the blocks and an adiabatic surface similar to the finite element model. (The bottom block rested on a rack with it s bottom surface exposed.) The experimental set-up is shown in Figure 3. In addition to the two blocks inside the refrigerator, another 40-lb. block was used as a control. This block was stored in a cooler maintained at a constant temperature of 45 F. The locations of the thermocouples for measuring the internal temperature of the cheese are shown on Figure 4. 5

6 Figure 3. Experimental Apparatus. Figure 4. Thermocouple Locations. Measurements were taken by the data logger every minute for each thermocouple; and, minimum, maximum, and average values were determined at the end of each hour. Data were obtained over a three-day period to assure that a steady response had been achieved. The three-day temperature plots were reduced to one-day plots by averaging the three points at identical locations in the cycle. The air temperature in the experimental chamber over a three-day period is shown in Figure 5. The cheese temperatures are shown in Figure 6. The results indicate that the experimental chamber was able to maintain the temperature to within two degrees of the setpoint. 6

7 The model predictions shown in Figure 2 are in agreement with the experimental results in Figure 6. The corner temperatures agree very well (within 5%) with the modeled corner temperatures, while the center displayed a somewhat slower response than predicted. This suggests that the chosen conductivity value for cheddar, Btu/(fthr-F), may be higher than that of the cheese blocks used. The close corner temperatures suggest that the refrigerator produced convection conditions close to those predicted for the warehouse conditions. Evaluation of Cycled Cheese The aging of cheddar cheese is an important factor in the taste and quality of the cheese. Aging is determined by bacterial growth on and inside the cheese, and is therefore strongly related to the temperature of the cheese. The optimum temperature for aging is considered by the industry to be 45 F for cheddar. The maximum allowable temperature is 48 F, and the minimum effective temperature is 40 F. Temperatures above 50 F are considered detrimental to the aging process and to affect the overall quality of the cheese. 7

8 Figure 5. Experiment Chamber Air Temperature. 55 Temperature (F) Time (hrs) Avg. Refrig. Air Max. Refrig. Air Min. Refrig. Air Figure 6. Cheese Temperature Results Avg. Air Avg. Corner Avg. Center Temperature (F) Time (hrs) 8

9 The cheese was evaluated by three faculty members from the UW Center for Dairy Research after being held in the experimental chamber for 90 days, and compared to the cheese aged at constant temperature. This experts panel was composed of experienced cheese tasters who have served as judges in numerous international cheese competitions. The unanimous decision was that the temperature cycling did no harm. Some slight problems with the control block occurred due to yeast and/or bacterial spoilage around the edges, but this spoilage did not occur with the cycled cheese. The consensus was that the cycled cheese might have not been aged quite as much as that stored at constant temperature. This is not unexpected, as the average temperature (42 F) was slightly below the control block (45 F). Further testing was not recommended as there were no signs of any problem and the differences found were expected to be much smaller than batch to batch differences in cheese. In addition to this experts panel, informal testing was done with two other groups: approximately 30 people present at the UW ESERC seminar and a similar number present at the ECW Board meeting. For these tests, the cheese was cut into thin sticks about 4 inches long. One end of this stick was the exposed face of the test block, which experienced the maximum temperature variation, and the other end was near the core, which experienced the minimum temperature variation. None of these tasters was able to detect a difference in flavor or texture between the two ends of the cheese sticks. Conclusions The model developed by Zehr predicts spatial variation in cheese blocks reasonably well. The demand control of the refrigeration system tested produced daily temperature variations of about 6 F in the center of a 40-pound block of cheese and 15 F near the exposed surface. These temperature variations had no discernable effect on cheese quality. The taste, texture, and appearance of the cheese aged with temperature cycling were indistinguishable form cheese aged in constant temperature storage. A larger scale experiment conducted in a warehouse is recommended. 9

Performance Considerations of the Thermal Envelope Moderator: Mike Adkins, United States Cold Storage

Performance Considerations of the Thermal Envelope Moderator: Mike Adkins, United States Cold Storage Performance Considerations of the Thermal Envelope Moderator: Mike Adkins, United States Cold Storage Panelists: Andy Bowser, Team Group Larry Gilliland, SubZero Constructors Jay Smith, Metl-Span Recommended

More information

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Chapter Six{ TC Chapter Six \l 1 } System Simulation Chapter Six{ TC "Chapter Six" \l 1 } System Simulation In the previous chapters models of the components of the cooling cycle and of the power plant were introduced. The TRNSYS model of the power plant

More information

ISOHOOD-2L2: Double-layer polyethylene bubble foil, coated with aluminum foil on both sides, PE-coating on aluminum foil

ISOHOOD-2L2: Double-layer polyethylene bubble foil, coated with aluminum foil on both sides, PE-coating on aluminum foil Page 1/7 THERMOCOVER ECO-SAFE ISOHOOD-2L2 Specification Thermocover for palletized gds, various dimensions, sewn Material ISOHOOD-2L2: Double-layer polyethylene bubble foil, coated with aluminum foil on

More information

Validation of Heating 7.2 Simulations Using Hot Box Test Data for RASTRA Wall Form System with Expanded Polystyrene Beads

Validation of Heating 7.2 Simulations Using Hot Box Test Data for RASTRA Wall Form System with Expanded Polystyrene Beads Validation of Heating 7.2 Simulations Using Hot Box Test Data for RASTRA Wall Form System with Expanded Polystyrene Beads Jan KoÑny and Phill Childs Oak Ridge National Laboratory Buildings Technology Center

More information

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS ANSI/DASMA 105-2017 AMERICAN NATIONAL STANDARD TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS ANSI/DASMA 105-2017 Door & Access Systems Manufacturers Association, International

More information

Opportunities and Limitations of Building Precooling

Opportunities and Limitations of Building Precooling Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1994 Opportunities and Limitations of Building Precooling K. R. Keeney Purdue

More information

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE Dr. Essam Al-Sayed Omar Department Manager Kuwait Institute for Scientific Research Kuwait ABSTRACT This paper addresses the

More information

Progress Report. Development of a High Heat Flux Supercooler Using Carbon Foam. Walter Yuen. February, 12, 2008

Progress Report. Development of a High Heat Flux Supercooler Using Carbon Foam. Walter Yuen. February, 12, 2008 Progress Report Development of a High Heat Flux Supercooler Using Carbon Foam By Walter Yuen February, 12, 2008 Introduction The objective of the work is to study the effectiveness of non-metallic foam

More information

Simulation of a Thermal Environment for Chilled Foods during Transport

Simulation of a Thermal Environment for Chilled Foods during Transport Simulation of a Thermal Environment for Chilled Foods during Transport D.Stubbs, S.H.Pulko, A.J.Wilkinson + Abstract Here we describe a modification of the existing treatments for thermal effects associated

More information

International Cold Chain Technology

International Cold Chain Technology INTERNATIONAL COLD CHAIN TECHNOLOGY 140 Newmarket Road, Cambridge CB5 8HE Tel: +44 1223 365101 Fax: +44 1223 461522 Email: icct@crtech.co.uk ICCT ICCT guidelines on Cargo Temperature Maintenance CONTENTS

More information

REFRIGERATED WAREHOUSES AND DEMAND RESPONSE

REFRIGERATED WAREHOUSES AND DEMAND RESPONSE REFRIGERATED WAREHOUSES AND DEMAND RESPONSE PRESENTED BY DOUG SCOTT VACOM TECHNOLOGIES 2012 EMERGING TECHNOLOGIES SUMMIT PASADENA, CALIFORNIA OCTOBER 15, 2012 REFRIGERATION + DR FUNDAMENTAL ATTRACTION

More information

Understanding Extrusion

Understanding Extrusion Chris Rauwendaal Understanding Extrusion 2nd Edition Sample Chapter 2: Instrumentation and Control ISBNs 978-1-56990-453-4 1-56990-453-7 HANSER Hanser Publishers, Munich Hanser Publications, Cincinnati

More information

Ground Source Heat Pumps: Testing three mediums surrounding the piping in geothermal field beds to evaluate performance

Ground Source Heat Pumps: Testing three mediums surrounding the piping in geothermal field beds to evaluate performance Ground Source Heat Pumps: Testing three mediums surrounding the piping in geothermal field beds to evaluate performance Bruce W. Smith, CPC and Mark C Tatum, P.E. Auburn University Auburn, Alabama The

More information

Technical Information

Technical Information General Applications Process Applications Determining Heat Energy Lost The objective of any heating application is to raise or maintain the temperature of a solid, liquid or gas to or at a level suitable

More information

PROCESS ENERGY EFFICIENCY IMPROVEMENT IN WISCONSIN CHEESE PLANTS

PROCESS ENERGY EFFICIENCY IMPROVEMENT IN WISCONSIN CHEESE PLANTS PROCESS ENERGY EFFICIENCY IMPROVEMENT IN WISCONSIN CHEESE PLANTS by STEPHEN ZEHR A thesis submitted in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE MECHANICAL ENGINEERING

More information

Modelling of Phase Change Material Implemented Into Cold Storage Application

Modelling of Phase Change Material Implemented Into Cold Storage Application Purdue University Purdue e-pubs International High Performance Buildings Conference School of Mechanical Engineering 2 Modelling of Phase Change Material Implemented Into Cold Storage Application Benjamin

More information

Steady-State R-Value Calculation. PS-4600 PolySteel Form

Steady-State R-Value Calculation. PS-4600 PolySteel Form Steady-State R-Value Calculation Introduction R value has been established as the primary measurement of energy efficiency in building construction. Steady state R value is the traditional method to determine

More information

Unsteady-State Simulation Using CHEMCAD Steady-State

Unsteady-State Simulation Using CHEMCAD Steady-State Unsteady-State Simulation Using CHEMCAD Steady-State State Jerry Hartis, Sr. Process Engineer Grant Duncan, Process Engineer Process Engineering Associates, LLC June 2008 Copyright 2009 Process Engineering

More information

SIMULATION AND MODEL CALIBRATION OF A LARGE-SCALE SOLAR SEASONAL STORAGE SYSTEM

SIMULATION AND MODEL CALIBRATION OF A LARGE-SCALE SOLAR SEASONAL STORAGE SYSTEM July August 1, SIMULATION AND MODEL CALIBRATION OF A LARGE-SCALE SOLAR SEASONAL STORAGE SYSTEM Timothy P. McDowell and Jeff W. Thornton Thermal Energy System Specialists, LLC, Madison, WI ABSTRACT The

More information

Thermal performance of a closed wet cooling tower for chilled ceilings: measurement and CFD simulation

Thermal performance of a closed wet cooling tower for chilled ceilings: measurement and CFD simulation INTERNATIONAL JOURNAL OF ENERGY RESEARCH Int. J. Energy Res. 2000; 24:1171}1179 Thermal performance of a closed wet cooling tower for chilled ceilings: measurement and CFD simulation Sa!a Ri!at*, Armando

More information

Demonstration of Load Shifting and Peak Load Reduction with Control of Building Thermal Mass

Demonstration of Load Shifting and Peak Load Reduction with Control of Building Thermal Mass Demonstration of Load Shifting and Peak Load Reduction with Control of Building Thermal Mass J. E. Braun and T. M. Lawrence, Ray W. Herrick Laboratories, Purdue University C. J. Klaassen and John M. House,

More information

Residential Swimming Pool Heating with Geothermal Heat Pump Systems

Residential Swimming Pool Heating with Geothermal Heat Pump Systems Residential Swimming Pool Heating with Geothermal Heat Pump Systems by Andrew Chiasson, P.E. ABSTRACT The objective of this study is to examine the feasibility of swimming pool heating with geothermal

More information

Dynamic Heat Process in a Climate Chamber

Dynamic Heat Process in a Climate Chamber M.Sc. Thesis E2011: 20 Dynamic Heat Process in a Climate Chamber Master thesis in Sustainable Energy Systems Lei Zou Göteborg, Sweden June 2011 CHALMERS UNIVERSITY OF TECHNOLOGY DEPARTMENT OF ENERGY AND

More information

AND TESTING OF A CARBON FOAM BASED SUPERCOOLER FOR HIGH HEAT FLUX COOLING IN OPTOELECTRONIC PACKAGES

AND TESTING OF A CARBON FOAM BASED SUPERCOOLER FOR HIGH HEAT FLUX COOLING IN OPTOELECTRONIC PACKAGES Proceedings of the ASME 2009 ASME 2009 InterPACK Conference IPACK2009 July 19-23, 2009, San Francisco, California, USA InterPACK2009-89008 IPACK2009-89008 DESIGN AND TESTING OF A CARBON FOAM BASED SUPERCOOLER

More information

Modeling Energy Consumption Effects of Glazing

Modeling Energy Consumption Effects of Glazing Modeling Energy Consumption Effects of Glazing Daniel Lu 12/7/2012 Table of Contents Introduction... 3 Design Options... 5 Option 1... 5 Option 2... 5 Preliminary Energy Simulation... 7 Objectives... 7

More information

Application Note AN 84/01. Pressure Transducer Temperature. Isolation Using Tubing. (Steady State Condition)

Application Note AN 84/01. Pressure Transducer Temperature. Isolation Using Tubing. (Steady State Condition) Application Note AN 84/01 Pressure Transducer Temperature Isolation Using Tubing (Steady State Condition) Revised August 19, 2002 Adam Kane Introduction Pressure Transducer Temperature Isolation Using

More information

ScienceDirect. Comparison of steady-state and in-situ testing of high thermal resistance walls incorporating vacuum insulation panels

ScienceDirect. Comparison of steady-state and in-situ testing of high thermal resistance walls incorporating vacuum insulation panels Available online at www.sciencedirect.com ScienceDirect Energy Procedia 78 (2015 ) 3246 3251 6th International Building Physics Conference, IBPC 2015 Comparison of steady-state and in-situ testing of high

More information

SUSCEPTIBILITY OF WEST INDIAN AVOCADOS TO CHILLING INJURY AS RELATED TO RAPID COOLING WITH LOW TEMPERATURE AIR OR WATER 1

SUSCEPTIBILITY OF WEST INDIAN AVOCADOS TO CHILLING INJURY AS RELATED TO RAPID COOLING WITH LOW TEMPERATURE AIR OR WATER 1 Proc. Fla. State Hort. Soc. 88:490-496. 1975. SUSCEPTIBILITY OF WEST INDIAN AVOCADOS TO CHILLING INJURY AS RELATED TO RAPID COOLING WITH LOW TEMPERATURE AIR OR WATER 1 J. J. Gaffney USDA, Agricultural

More information

The Novel Solar Water Heating by Means of Thermoelectric Modules

The Novel Solar Water Heating by Means of Thermoelectric Modules International Journal of Renewable Energy, Vol. 3, No. 2, July 2008 The Novel Solar Water Heating by Means of Thermoelectric Modules Somchai Maneewan a*, Sirinuch Chindaruksa a and Jompob Waewsak b a Physics

More information

The Potential for Graphite Oxidation in Dry Wall ICF Chambers

The Potential for Graphite Oxidation in Dry Wall ICF Chambers The Potential for Graphite Oxidation in Dry Wall ICF Chambers El S. Mogahed, I. N Sviatoslavsky, J. G. Murphy, H. Y. Khater, M. H. Anderson, and G. L. Kulcinski Fusion Technology Institute University of

More information

Technical Report ARAEW-TR A THERMAL PERFORMANCE STUDY OF THE 155MM XM297 ACTIVELY COOLED BARREL

Technical Report ARAEW-TR A THERMAL PERFORMANCE STUDY OF THE 155MM XM297 ACTIVELY COOLED BARREL AD Technical Report ARAEW-TR-622 A THERMAL PERFORMANCE STUDY OF THE 155MM XM297 ACTIVELY COOLED BARREL MARK D WITHERELL NOVEMBER 26 ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER Armaments Engineering

More information

ESPEC Solar Application Guide

ESPEC Solar Application Guide ESPEC Solar Application Guide Review of the IEC 61215 and 61646 methods ESPEC North America 1 Contents Introduction: 3 Section 1: Technical Issue with the Standards 4 Air-temperature versus Module-temperature

More information

Heat Treating Copper Beryllium Parts

Heat Treating Copper Beryllium Parts Heat Treating Copper Beryllium Parts Heat treating is key to the versatility of the copper beryllium alloy system. Unlike other copper base alloys which acquire their strength through cold work alone,

More information

E APPENDIX. The following problems are intended for solution using finite element. Problems for Computer Solution E.1 CHAPTER 3

E APPENDIX. The following problems are intended for solution using finite element. Problems for Computer Solution E.1 CHAPTER 3 E APPENDIX Problems for Computer Solution The following problems are intended for solution using finite element analysis software. In general, the problems associated with Chapters 3, 4, and 9 can be solved

More information

Performance Improvement on Water-cooled Cold-Plate

Performance Improvement on Water-cooled Cold-Plate Proceedings of the 4th WSEAS International Conference on Heat and Mass Transfer, Gold Coast, Queensland, Australia, January 17-19, 2007 104 Performance Improvement on Water-cooled Cold-Plate SHYAN-FU CHOU,

More information

FINITE ELEMENT ANALYSIS OF THERMAL TENSIONING TECHNIQUES MITIGATING WELD BUCKLING DISTORTION

FINITE ELEMENT ANALYSIS OF THERMAL TENSIONING TECHNIQUES MITIGATING WELD BUCKLING DISTORTION FINITE ELEMENT ANALYSIS OF THERMAL TENSIONING TECHNIQUES MITIGATING WELD BUCKLING DISTORTION Panagiotis Michaleris The Pennsylvania State University University Park, PA and Xin Sun Battelle Columbus, OH

More information

THERMAL PROCESSING THEORY

THERMAL PROCESSING THEORY THERMAL PROCESSING THEORY 8.1 Infrared Waves Infrared waves form part of the electromagnetic spectrum. Electromagnetic waves with wavelengths from 0.78 µm to 1000 µm are called infrared waves. You are

More information

Temperature Controlled. You Might Not Know

Temperature Controlled. You Might Not Know Temperature Controlled Packaging: Considerations You Might Not Know June 17, 2014 1 Introductions Ken Maltas Director of Engineering 7 years cold chain, 35 years medical packaging Bradley University BSIE

More information

High-Temperature Refrigerated Warehouse Operation under Real-Time Pricing of Electricity

High-Temperature Refrigerated Warehouse Operation under Real-Time Pricing of Electricity High-emperature Refrigerated Warehouse Operation under Real-ime Pricing of Electricity by Nitin Magoo A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science (Mechanical

More information

Experimental and numerical investigation of cooling performance of a cold storage in a pharmaceutical industry

Experimental and numerical investigation of cooling performance of a cold storage in a pharmaceutical industry Journal of Physics: Conference Series PAPER OPEN ACCESS Experimental and numerical investigation of cooling performance of a cold storage in a pharmaceutical industry To cite this article: A Sularno et

More information

THERMAL CONDUCTIVITY MEASUREMENT OF POWDER MATERIAL AND ITS OPTIMUM APPLICATION FOR ENERGY EFFICIENT COLD STORAGE

THERMAL CONDUCTIVITY MEASUREMENT OF POWDER MATERIAL AND ITS OPTIMUM APPLICATION FOR ENERGY EFFICIENT COLD STORAGE THERMAL CONDUCTIVITY MEASUREMENT OF POWDER MATERIAL AND ITS OPTIMUM APPLICATION FOR ENERGY EFFICIENT COLD STORAGE * Suman B.M. CSIR- Central Building Research Institute, Roorkee, Uttarakhand 247667, India

More information

Moisture risks of passive retrofitting one town house for the adjacent conventional neighboring structures

Moisture risks of passive retrofitting one town house for the adjacent conventional neighboring structures Moisture risks of passive retrofitting one town house for the adjacent conventional neighboring structures 9 th Passive house conference, September 10-14, 2014, San Francisco Matthias Pazold Auf Wissen

More information

Solar cell junction temperature measurement of PV module

Solar cell junction temperature measurement of PV module Available online at www.sciencedirect.com Solar Energy 85 (2011) 388 392 www.elsevier.com/locate/solener Solar cell junction temperature measurement of PV module B.J. Huang a,, P.E. Yang a, Y.P. Lin a,

More information

Temperature-Controlled Packaging for Reusable Containers Using IPC's GreenLiner Thermal Box Liner WHITE PAPERS

Temperature-Controlled Packaging for Reusable Containers Using IPC's GreenLiner Thermal Box Liner WHITE PAPERS Temperature-Controlled Packaging for Reusable Containers Using IPC's GreenLiner Thermal Box Liner WHITE PAPERS Reusable containers are designed to be used repeatedly, or indefinitely, for the distribution,

More information

EXPERIMENTAL INVESTIGATION OF A SCALED REACTOR CAVITY COOLING SYSTEM WITH AIR FOR THE VHTR

EXPERIMENTAL INVESTIGATION OF A SCALED REACTOR CAVITY COOLING SYSTEM WITH AIR FOR THE VHTR EXPERIMENTAL INVESTIGATION OF A SCALED REACTOR CAVITY COOLING SYSTEM WITH AIR FOR THE VHTR M. A. Muci 1, D. D. Lisowski 2, M. H. Anderson 3, and M. L. Corradini 3 1 : Duke Energy, 139 East 4 th Street

More information

Rate of Hydration is Exponentially Sensitive to Temperature. NPCA Precast Show Focus on Concrete Temperature. March 2, 2019

Rate of Hydration is Exponentially Sensitive to Temperature. NPCA Precast Show Focus on Concrete Temperature. March 2, 2019 FOCUSING ON CONCRETE TEMPERATURE: WHY HIGH EARLY TEMPERATURE HELPS AND HURTS Ken Hover, Ph.D., P.E., Professor of Civil & Environmental Engineering, Cornell University FOCUSING ON CONCRETE TEMPERATURE

More information

Batch Annealing Model for Cold Rolled Coils and Its Application

Batch Annealing Model for Cold Rolled Coils and Its Application China Steel Technical Report, No. 28, pp.13-20, (2015) Chun-Jen Fang and Li-Wen Wu 13 Batch Annealing Model for Cold Rolled Coils and Its Application CHUN-JEN FANG and LI-WEN WU New Materials Research

More information

Large University Central Chiller Plant Design Considerations

Large University Central Chiller Plant Design Considerations Carrier Engineering Newsletter Volume 5, Issue 3 Large University Central Chiller Plant Design Considerations Large campus chilled water plants have unique constraints and need careful evaluation for successful

More information

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies Report Number: 5160440 August 18 th, 2016 3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies Presented to: Lenmak Exterior Innovations Inc. 10404-176 Street Edmonton,

More information

Comparing Fire Response of Simulated Rocket Motors in Steel and Carbon Fiber Composite Missile Launching Canisters

Comparing Fire Response of Simulated Rocket Motors in Steel and Carbon Fiber Composite Missile Launching Canisters Comparing Fire Response of Simulated Rocket Motors in Steel and Carbon Fiber Composite Missile Launching Canisters Jon J. Yagla, PhD. Insensitive Munitions and Energetic Materials Technology Symposium

More information

Cooling Tower Operation

Cooling Tower Operation Cooling Tower Operation Forced draught cooling towers use the evaporation of a liquid (often water) into air to achieve cooling. The tower often consists of a sprinkler system which wets a high-surface-area

More information

Need help? Give us a call.

Need help? Give us a call. Need help? Give us a call. Call our support line at 1.800.765.6699 if you are unclear on any step of the application. You ll be helped by an experienced professional painter, just like you. WEB: www.zolatone.com

More information

Thermally operated mobile air-conditioning system

Thermally operated mobile air-conditioning system Thermally operated mobile air-conditioning system Development and test of a laboratory prototype R. de Boer S.F. Smeding Paper to be presented on the International Sorption Heat Pump Conference 2008, Seoul,

More information

TOPIC: KNOWLEDGE: K1.01 [2.5/2.5]

TOPIC: KNOWLEDGE: K1.01 [2.5/2.5] KNOWLEDGE: K1.01 [2.5/2.5] P283 The transfer of heat from the reactor fuel pellets to the fuel cladding during normal plant operation is primarily accomplished via heat transfer. A. conduction B. convection

More information

Mathematical Modelling of an Annealing Furnace for Process Control Applications

Mathematical Modelling of an Annealing Furnace for Process Control Applications Mathematical Modelling of an Annealing Furnace for Process Control Applications N.Depree 1, J.Sneyd 2, S.Taylor 2, M.P.Taylor 1, M.O Connor 3, J.J.J.Chen 4 1 Light Metals Research Centre, University of

More information

Energy savings potential using the thermal inertia of a low temperature storage

Energy savings potential using the thermal inertia of a low temperature storage Energy savings potential using the thermal inertia of a low temperature storage D. Leducq, M. Pirano, G. Alvarez To cite this version: D. Leducq, M. Pirano, G. Alvarez. Energy savings potential using the

More information

Analyses of the Impact of Loss of Spray-Applied Fire Protection on the Fire Resistance of Steel Columns

Analyses of the Impact of Loss of Spray-Applied Fire Protection on the Fire Resistance of Steel Columns Analyses of the Impact of Loss of Spray-Applied Fire Protection on the Fire Resistance of Steel Columns James A. Milke, University of Maryland, USA Noah L. Ryder, Combustion Science & Engineering, Inc.,

More information

Development of a cooling system for geothermal borehole probes

Development of a cooling system for geothermal borehole probes Development of a for geothermal borehole Benedict Holbein National Research Center of the Helmholtz Association www.kit.edu application range open tasks Structure of presentation Why the system is needed

More information

Performance Characteristics and Mapping for a Variable-Speed Ductless Heat Pump

Performance Characteristics and Mapping for a Variable-Speed Ductless Heat Pump Purdue University Purdue e-pubs Publications of the Ray W. Herrick Laboratories School of Mechanical Engineering Performance Characteristics and Mapping for a Variable-Speed Ductless Heat Pump Howard Cheung

More information

ASTM C 1363 Thermal Performance Test Report

ASTM C 1363 Thermal Performance Test Report ASTM C 1363 Thermal Performance Test Report Test Number: 2010-50 Sponsor: Butler Research Center Liner System R-25 + R-11 Membrane liner system, R-25 fiberglass insulation between the purlins, R-11 fiberglass

More information

Alexandra Thewis. Stephen Pessiki. Michael McGinnis. ATLSS Report No May 2007

Alexandra Thewis. Stephen Pessiki. Michael McGinnis. ATLSS Report No May 2007 Analytical Investigation of Systematic Increases in Column Section and Insulation Thickness on the Axial Load Capacity of Steel Building Columns in Fire by Alexandra Thewis Stephen Pessiki Michael McGinnis

More information

AC2 Evaporative Condenser. Monitoring Report: 1998 Cooling Season

AC2 Evaporative Condenser. Monitoring Report: 1998 Cooling Season AC2 Evaporative Condenser Monitoring Report: 1998 Cooling Season Report Issued: December 29, 1998 Presented to: Prepared by: Lance Elberling Pacific Gas and Electric Company Davis Energy Group 123 C Street

More information

System Cooling of Outdoor Wi-Fi Antenna

System Cooling of Outdoor Wi-Fi Antenna System Cooling of Outdoor Wi-Fi Antenna Robert Raos, Solectron Corporation MEPTEC Thermal Symposium February 16, 2005 Topics Requirements and Constraints Cooling Methods and Trade off Analysis System Cooling

More information

In general, passive-solar components can be described by the U-value (heat loss coefficient) and

In general, passive-solar components can be described by the U-value (heat loss coefficient) and SIMULATION OF A PHOTOVOLTAIC HYBRID FACADE Olaf Gutschker and Harald Rogaß Brandenburgische Technische Universität Cottbus Lehrstuhl für Angewandte Physik Postfach 101344, D-03013 Cottbus Germany ABSTRACT

More information

Equinox House Project. Topic 1 House Energy Requirements. Ty Newell January 27, 2010

Equinox House Project. Topic 1 House Energy Requirements. Ty Newell January 27, 2010 House Project Topic 1 House Energy Requirements Ty Newell January 27, 2010 The House is a zero energy house, or as I like to describe it, a zero plus house, meaning it provides both house operation energy

More information

T A ~ box is divided into chambers. The

T A ~ box is divided into chambers. The AN EVALUATION OF THE PLACEMENT OF RADIANT BARRIERS ON THEIR. EFFECTIVENESS IN REDUCING HEAT TRANSFER IN ATTICS Srinivas Katipamula and Dennis L. OVNeal Texas A&M University Department of Mechanical Engineering

More information

Box Load Calculation

Box Load Calculation Box Load Calculation Quote/Order # 7-IB-69 Box #: Box Description: 8' - " x 7' - 8" x 8' - " rectangular indoor freezer/cooler combo - 7' - 4" ID x 4' - 4" ID x 7' - 3 /2" ID freezer (with floor) - 7'

More information

COMBINED EXPERIMENTAL AND SIMULATION (CFD) ANALYSIS ON PERFORMANCE OF A HORIZONTAL TUBE REACTOR USED TO PRODUCE CARBON NANOTUBES

COMBINED EXPERIMENTAL AND SIMULATION (CFD) ANALYSIS ON PERFORMANCE OF A HORIZONTAL TUBE REACTOR USED TO PRODUCE CARBON NANOTUBES Seventh International Conference on CFD in the Minerals and Process Industries CSIRO, Melbourne, Australia 9-11 December 2009 COMBINED EXPERIMENTAL AND SIMULATION (CFD) ANALYSIS ON PERFORMANCE OF A HORIZONTAL

More information

Joe Colannino and Roberto Ruiz, ClearSign Combustion, USA, NO formation

Joe Colannino and Roberto Ruiz, ClearSign Combustion, USA, NO formation Joe Colannino and Roberto Ruiz, ClearSign Combustion, USA, introduce an innovative piece of technology that was able to help a Californian refinery reduce its NOX emissions R efinery fuels present manifold

More information

Southern California Gas Company Customer Programs Department

Southern California Gas Company Customer Programs Department Appliance Test Report SCGAT130514A Lang GCSF-ES-NAT Gas Convection Oven Performance Test Revision 0 Southern California Gas Company Customer Programs Department Issued Date: June 2013 2009 Southern California

More information

Quenching steels with gas jet arrays

Quenching steels with gas jet arrays Quenching steels with gas jet arrays PAUL F STRATTON ANDREW P RICHARDSON BOC Rother Valley Way, Holbrook, Sheffield UNITED KINGDOM Paul.stratton@boc.com http://www.catweb.boc.com Abstract: - Single components

More information

CHAPTER 7 THERMAL ANALYSIS

CHAPTER 7 THERMAL ANALYSIS 102 CHAPTER 7 THERMAL ANALYSIS 7.1 INTRODUCTION While applying brake, the major part of the heat generated is dissipated through the brake drum while the rest of it goes into the brake shoe. The thermal

More information

Civil and Environmental Engineering

Civil and Environmental Engineering Lehigh University Lehigh Preserve ATLSS Reports Civil and Environmental Engineering 5-1-2007 Analytical Investigation of Systematic Increases in Column Section and Insulation Thickness on the Axial Load

More information

by Hill K. Nandi CompAS Controls Inc. Indiana, Pa.

by Hill K. Nandi CompAS Controls Inc. Indiana, Pa. SOFTWARE TOOL OPTIMIZES FURNACE DESIGN AND OPERATION Adapted from an article published in the November 2002 issue of Heat Treating Progress. Copyright 2002, by ASM International, Materials Park, Ohio.

More information

Development of Energy-Saving High-Performance Continuous Carburizing Furnace

Development of Energy-Saving High-Performance Continuous Carburizing Furnace TECHNICAL REPORT Development of Energy-Saving High-Performance Continuous Carburizing Furnace M. MINAMIGUCHI T. SAITOU Koyo Thermo Systems Co., Ltd. and JTEKT Corporation have jointly developed an energy-saving

More information

Where WVDOH is at with Mass Concrete

Where WVDOH is at with Mass Concrete Where WVDOH is at with Mass Concrete History of Mass Concrete and the WVDOH In 2005, a large bridge crossing the Ohio River was being constructed (Blennerhassett Bridge) Because of the large size of some

More information

VADOSE/W 2D Tutorial

VADOSE/W 2D Tutorial 1 Introduction VADOSE/W 2D Tutorial This example illustrates the basic methodology for simulating soil-climate interaction of an engineered soil cover system placed over a waste. The primary objective

More information

INSTALLATION OF REFRACTORY FIBER KILN AND FURNACE LININGS

INSTALLATION OF REFRACTORY FIBER KILN AND FURNACE LININGS INSTALLATION OF REFRACTORY FIBER KILN AND FURNACE LININGS Considerable technology has been developed in the installation of refractory (ceramic) fiber kiln and furnace linings. Techniques for lining new

More information

White Paper. Geothermal Heating and Cooling

White Paper. Geothermal Heating and Cooling White Paper Geothermal Heating and Cooling The fundamentals of a geoexchange system (geothermal heating and cooling system) are well understood and although many factors need to be considered when designing

More information

Optimal design of a beam stop for Indus-2 using finite element heat transfer studies

Optimal design of a beam stop for Indus-2 using finite element heat transfer studies Sādhan ā Vol. 26, Part 6, December 2001, pp. 591 602. Printed in India Optimal design of a beam stop for Indus-2 using finite element heat transfer studies A K SINHA, KJSSAWHNEY andrvnandedkar Synchrotron

More information

FORMLABS WHITE PAPER: How Mechanical Properties of Stereolithography 3D Prints are Affected by UV Curing. By Zachary Zguris, PhD formlabs.

FORMLABS WHITE PAPER: How Mechanical Properties of Stereolithography 3D Prints are Affected by UV Curing. By Zachary Zguris, PhD formlabs. FORMLABS WHITE PAPER: How Mechanical Properties of Stereolithography 3D Prints are Affected by UV Curing By Zachary Zguris, PhD formlabs.com ABSTRACT The post-cure of parts printed with Formlabs resins

More information

The ATI 17-4 precipitation hardening stainless steel (S17400) is covered by the following wrought product specifications.

The ATI 17-4 precipitation hardening stainless steel (S17400) is covered by the following wrought product specifications. ATI 17-4 Precipitation Hardening Stainless Steel (UNS S17400) INTRODUCTION ATI 17-4 precipitation hardening stainless steel (S17400), Type 630, is a chromium-nickel-copper precipitation hardening stainless

More information

TR Test Report Verification Testing RKN e1 Container (+5 C) Worst Case Load Version: 01 Page: 2 (26)

TR Test Report Verification Testing RKN e1 Container (+5 C) Worst Case Load Version: 01 Page: 2 (26) TR120013-01 Test Report Verification Testing RKN e1 Container (+5 C) Worst Case Load Version: 01 Page: 2 (26) Document History Version Date of issue Revision(s) Issued by 01 20FEB2012 N/A (First version

More information

VADOSE/W 2D Tutorial

VADOSE/W 2D Tutorial Elevation 1 Introduction VADOSE/W 2D Tutorial This example illustrates the basic methodology for simulating soil-climate interaction of an engineered soil cover system placed over a waste. The primary

More information

Farm Energy IQ. Farms Today Securing Our Energy Future. Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station

Farm Energy IQ. Farms Today Securing Our Energy Future. Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station Farm Energy IQ Farms Today Securing Our Energy Future Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station Farm Energy IQ Farm Energy Efficiency Principles Tom Manning,

More information

ANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers"

ANSI/IEEE Standard C57.12Standard Guide for Loading Mineral Oil Insulated Transformers References: ANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers" IEEE Project P1276 "IEEE Guide for the Application of High Temperature Insulation Materials in Liquid

More information

Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF

Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF Why do we need to cover the SPF Spray Polyurethane Foam (SPF) is combustible As the SPF burns and

More information

Grade 7. Unit 3 Heat and Temperature

Grade 7. Unit 3 Heat and Temperature Grade 7 Unit 3 Heat and Temperature Developed by Edquest Resources 2001 Using Energy Investigation 3-A Page 189 Problem: Can a survey, by students in the school, provide enough information to make conclusions

More information

Constant Temperature Lab Equipment and Thermoelectric Technology

Constant Temperature Lab Equipment and Thermoelectric Technology A SHEL LAB 300 N. 26 th Avenue Cornelius, Oregon 97113 503-640-3000 www.shellab.com Constant Temperature Lab Equipment and Thermoelectric Technology By Henry Morgan Quality and Test Manager September,

More information

CAPS TM V5. Software Suite. Get the Most Out of Your Anneal Shop. RAD-CON, Inc Athens Ave.

CAPS TM V5. Software Suite. Get the Most Out of Your Anneal Shop.   RAD-CON, Inc Athens Ave. CAPS TM V5 RAD-CON, Inc. 13001 Athens Ave. Suite 300 Lakewood, OH 44107 Phone: +1 440-871-5720 Fax: +1 216-221-1135 E-mail: sales@rad-con.com Web: www.rad-con.com Optimized by: Software Suite Get the Most

More information

Battery thermal models for hybrid vehicle simulations

Battery thermal models for hybrid vehicle simulations Journal of Power Sources 110 (2002) 377 382 Battery thermal models for hybrid vehicle simulations Ahmad A. Pesaran National Renewable Energy Laboratory, 1617 Cole Blvd, Golden, CO 80401, USA Abstract This

More information

OVERVIEW OF PROCEDURE 2A

OVERVIEW OF PROCEDURE 2A Packaged-Products 150 lb (68 kg) or Less 2A 2 008 ISTA 2 Series Partial Simulation Performance Test Procedure VERSION DATE Last TECHNICAL Change: JANUARY 2008 Last EDITORIAL Change: JANUARY 2008 For complete

More information

Introduction to Geothermal Comfort Systems in INDIA

Introduction to Geothermal Comfort Systems in INDIA Introduction to Geothermal Comfort Systems in INDIA History Ancient earth sheltered homes 1912 Swiss Patent 1945 - First GSHP operating in North America in Indianapolis 1949 Canada s first GSHP installation

More information

Prediction of Gas Hydrates Formation in Flow lines

Prediction of Gas Hydrates Formation in Flow lines ICCPGE 2016, 1, 25-30 Prediction of Gas Hydrates Formation in Flow lines M.G. Mounis 1, B. A. Hussien 1, F. E. Galoul 1, Dr. Hasan M. Asharif 1 and Mahmoud Said 2 1 Chemical Eng. Department, Faculty of

More information

The Effect of Reflow Profiling on the Electrical Reliability of No-Clean Solder Paste Flux Residues

The Effect of Reflow Profiling on the Electrical Reliability of No-Clean Solder Paste Flux Residues The Effect of Reflow Profiling on the Electrical Reliability of No-Clean Solder Paste Flux Residues Abstract Eric Bastow Indium Corporation Clinton, New York An estimated 80% of all SMT assembly in the

More information

AGA Roof Deck Pavers. AGA Concrete Paver. Technical. Pavers: Hydraulically pressed concrete pavers: 460 tons of pressure.

AGA Roof Deck Pavers. AGA Concrete Paver. Technical. Pavers: Hydraulically pressed concrete pavers: 460 tons of pressure. Cut Sheet AGA Roof Deck Pavers AGA Concrete Paver Overview: AGA Standard sized pavers are manufactured to meet project requirements. Custom: we offer a variety of custom sizes and a mixture of colors and

More information

LOGO. Trivium Level II Energy Audit

LOGO. Trivium Level II Energy Audit LOGO Trivium Level II Energy Audit Submission Date: 9/16/2016 Table of Contents 1.0 EXECUTIVE SUMMARY 3 2.0 SITE ENERGY CONSUMPTION 5 3.0 BACKGROUND INFORMATION 6 3.1 Description of the Client 6 3.2 Description

More information

TEMPERATURE AND HEAT DISTRIBUTION PROTOCOL FOR PROCESSING IN DISCONTINUOUS AGITATING RETORTS

TEMPERATURE AND HEAT DISTRIBUTION PROTOCOL FOR PROCESSING IN DISCONTINUOUS AGITATING RETORTS Institute For Thermal Processing Specialists www.iftps.org 304 Stone Road West, Suite 301 Guelph, ON N1G 4W4 Phone (519) 824-6774. Fax (519) 824-6642 TEMPERATURE AND HEAT DISTRIBUTION PROTOCOL FOR PROCESSING

More information

BUREAU OF INDIAN STANDARDS Draft Indian Standard

BUREAU OF INDIAN STANDARDS Draft Indian Standard Doc:MTD 15(5106) For Comments Only BUREAU OF INDIAN STANDARDS Draft Indian Standard METHOD FOR DETERMINATION OF THERMAL CONDUCTIVITY OF DENSE AS WELL AS INSULATING FIRED REFRACTORIES, REFRACTORY MONOLITHICS

More information

Recycled Materials as Insulation. Topic of the Research Paper- Examining the insulating capacity of recyclable materials

Recycled Materials as Insulation. Topic of the Research Paper- Examining the insulating capacity of recyclable materials International Journal of Scientific & Engineering Research, Volume 7, Issue 12, December-2016 Recycled Materials as Insulation Topic of the Research Paper- Examining the insulating capacity of recyclable

More information