1 Residential Elevators Safe Reliable Affordable Convenient J.T. Lawrence & Company
2 Introduction Thank you for your interest our product. Our elevators are custom manufactured to meet your specifications and needs. We manufacture both affordable and high-end residential elevators. The lifting capacity of this elevator can either be 750 lbs. or 950 lbs. You can be proud of the fact that you will join countless others who have turned to JT Lawrence & Co. for the ideal solution to their accessibility problems. As you will soon discover, your elevator will be easy to operate and has been designed for years of dependable and trouble-free operation. But remember... If you do require service, only an authorized JT Lawrence & Co. dealer has the factory trained technicians with the required tools and replacement parts needed to properly repair your elevator. They are committed to providing quality and excellent service for you. Whether you desire a valuable asset your home or the necessity to enable you to have access to all floors of your home; we can help. Our elevators are roped hydraulic, which ensures a smooth and quiet ride. And unlike other manufactures who build all types of elevators, our focus is only residential elevators. What this means to you is our facility is designed around building just your elevator. And our dedication is to continue to improve on existing practices and techniques, constantly making a better elevator for you and others in the future. So, before you build, call us. Preparing ahead will save you time and money with your new elevator. Contact us to better understand what is required before you build. We also have a wide range of details and information which can be relayed to the architect working on your plans. Look to us for your future, include our elevator into your plans. You don t have to shut off the upper rooms to your house during those golden years. Not only will you be able to access those rooms again, but our elevator will increase the value of your home and the quality of your life. Even if you have an existing home, an elevator can still fit into your plan. All of our distributors are licensed elevator contractors and have a minimum of 5 years experience installing elevators. Each elevator is custom designed and built to meet your needs. As well as conforming to and exceeding ANSI / ASME A and A Elevator and Escalators safety codes. Requirements Our residential elevator has the capacity to fit into a limited space. If you have approximately 20 square feet our elevator will meet your minimal requirements. We custom build every elevator to your specifications and space limitations. An 8 recessed pit is required for all elevators to insure proper running clearances. With a standard cab height of 6-8 you will only need an overhead (distance from the top floor to the ceiling) of 8-0. This space increases as the cab height increases. The general contractor on the job will need to provide two circuits for the elevator to the machine room. One 220 Volt circuit for the elevator and one 110 volt circuit for the car lighting. Horizontal or vertical supports in one wall will be required to withstand the weight of the elevator. Your elevator contractor will have all specifications for the location of these supports. Our standard production lead times are between six and eight weeks from the time our facility receives final information from the elevator contractor verifying the conditions and sizes available for your elevator.
3 These cabs are constructed from 3/4 thick real wood veneer plywood. We do not utilize particle board in any of our products.
4 Our Series 2000 cabs solid hardwood 7/8 thick. They are constructed with true raised panels. Each elevator is customized to your specifications.
5 These cabs have a durable white vinyl coating to aid in the durability of this cab. The raised panels have been routed into the walls to give the look of commercial grade cabinetry.
6 Our glass back cabs have all the same specifications as the Series 2000 cabs plus a window integrated into the wall panel.
7 This cab has the antique look and feel. We ve incorporated beaded board into the interior of the elevator. This cab series can be painted to meet your needs.
8 Series 6000 cabs have the same beaded board walls as the Series 5000 but can be stained to specifications.
9 Wood Finishes: The basic building blocks of our elevator cabs are select hardwoods and veneers. The unique beauty and elegance of hardwood is expressed in the character of each unique piece of hardwood as it is finished into a fine cabinetry like look. Just as no two trees are alike, no two pieces of wood are alike. This natural occurrence can result in the beautiful variations in grain and color throughout your elevator. Color variations are more pronounced in the lighter stain colors. After hardwoods are finished they are affected by exposure to sunlight and other types of light. This slow change, called "mellowing", is always occurring so that in a year's time, a significant difference in the color has occurred. New elevator cabs will never be the same color after time as originally shipped. Series 1000, 2000 & Wood Species Available Birch is not available on Series 2000 and Series 4000 cabs. Alder is not available on Series 1000 cabs. Red Oak Birch Maple Alder Ash Cherry Mahogany Walnut Series Colors Available Series Colors Available White Black White Off White Series Colors Available Colors shown left are natural finish. Stain colors below are shown applied over red oak. Oak Birch Stain colors The colors shown are for reference purposes only. 209 Natural 210B Golden Oak 211 Provincial 215 Red Oak 218 Puritan Pine 221 Ipswich Pine 222 Sedona Red 223 Colonial Maple 224 Special Walnut 225 Red Mahogany 230 Early American 233 English Chestnut 235 Cherry 241 Fruitwood 245 Golden Pecan 260 Pickled Oak 2126 Driftwood 2716 Dark Walnut 2718 Ebony 2750 Jacobean Variations in darkness and grain are dependent on the color and grain of the veneer as described above. Actual wood color may differ from that actually supplied.
10 Hydraulic Pump Unit
11 Microprocessor Controller
12 Standard Sizes Inline Openings Note: All dimensions are from finished sheetrock
13 Standard Sizes Opposite and Adjacent Openings Note: All dimensions are from finished sheetrock
14 Standard Sizes Vertical Dimensions and Electrical Requirements Notes: OH or Overhead is measured from the floor of the top landing to the underside of the ceiling inside the elevator shaft. TT or Total Travel is measured from the floor of the bottom landing to the floor of the top landing. The machine room should have a minimum of 7-0 ceiling height and be equipped with a minimum 2-6 access door. (by G.C.) A light switch with adequate lighting and a GFI outlet should also be located in the machine room. (by G.C.) Electrical & Phone Requirements Each elevator requires one (1) 220VAC 30 amp fused disconnect for the elevators main power. The power on the 220V line MUST be a 10-3 wire with a ground and insure that there is a dedicated neutral to the elevator unit. (by G.C.) Each elevator will also require one (1) 120VAC 15 amp fused disconnect or circuit breaker for the cab lighting. (by G.C.) A standard telephone line must also be pulled to the elevator machine room with approximately ten feet extra length inside the machine room. (by G.C.)
15 Elevator Terminology Battery Backup - This comes on in the event of a power failure and allows the elevator to go down. This also initiates the emergency light inside the car. C.O.P. - The Car Operating Panel or C.O.P. is the panel located inside the elevator that has the buttons, key switch, emergency light and stop switch. Car or Cab - Refers to the part of the elevator you ride in. Controller - The brain of the elevator. Typically located in a machine room, this piece of equipment has all the control circuits for running the elevator. Gate - The gate is the accordion door located on the elevator itself. This door prevents people or objects from coming into contact with objects outside the elevator when traveling. Hall Station - This is the panel located just outside the elevator used to call the elevator to that floor. Hoistway - The enclosed space inside the house where the elevator travels. Also called a shaft. Hoistway Door - The swing door used to get into the elevator. Also called the hall door. Interlock - Also called the door lock, is an electro-mechanical interlock which prevents the swing door from opening when the elevator is not at that floor. Jack - This is the hydraulic equipment used to lift and lower the elevator in conjunction with the cables. Overhead - The distance from the floor of the top landing to the ceiling inside the hoistway. Pit - The recessed area below the bottom floor which allows enough clearance for the elevator supporting equipment and the elevator floor to be level with the bottom floor. Rail - The steel section inside the elevator hoistway that guide the elevator when traveling up and down. Sheave - This sets on top of the jack and is basically a pulley. Sling - This is the section that holds the elevator cab and is attached to the rails. This section moves up and down with the elevator. Travel - Also referred to as total travel. This is the dimension from the floor of the bottom landing to the floor of the top landing.
16 Part 1 GENERAL 1.01 Section Includes Specifications A. Furnish and provide all materials and labor necessary for the complete installation of the residential elevator. B. Obtain information on conditions affecting work at jobsite. Include verification of dimensions, field material for anchoring, accessibility and storage space. Verify voltages and outlets on electrical drawings Work Done By Others A. Pit poured to correct dimensions front to back and side to side and depth from the finished first floor level as indicated on the final layout drawings. B. Pit floor to be designed for an impact load of 3500 ftlbs. C. Machine room with an entrance door as indicated on the final layout drawings. D. Suitable, legal, two-hour fire-rated hoistway, if consistent with building construction. E. Electrician shall furnish a 30 amp, 220 volt single phase circuit with neutral and a ground to the elevator machine room for wiring to the controller. A separate 10 amp,120 volt single phase circuit to be run to the elevator machine room for wiring the cab lights in the controller. Disconnects for main power and car lighting are provided in the controller by the elevator manufacturer. F. A 110 volt outlet and light must be provided in the machine room. The machine room light switch must be located in the machine room area nearest to the machine room door as per NAEC PART 620. G. A telephone cable to an outside exchange, as required by ANSI A17.1 CODE References Design and installation shall be in compliance with regulations and all government agencies. Lift shall be subject to local, city and state approval prior to installation, along with city and state inspection after installation. Special local requirements shall be determined and handled locally by the distributor with the manufacturer's agreement Submittals Drawings shall be submitted with manufacture's literature for approval. Drawings shall include rough-in and wiring requirements Substitutions No substitutions will be considered unless written request for approval has been submitted by the bidder and was received by the architect at least ten (10) days prior to the date of receipt of bids. Each such request shall include the name of the materials for which it is to be substituted and a complete description of the proposed substitute including drawings, cuts, mock-ups, performance and test date, a list of projects of similar scope, photographs of existing installations and any other information necessary for evaluation. Part 2 PRODUCTS 2.01 Product Type A. Type of elevator shall be 1:2 roped-hydraulic elevator unit. B. Car to be inches wide by inches deep with a minimum inside clear height of 6'- 8. Lifting capacity to be 750 pounds. Elevator serves stops and travels a total distance of feet inches. Provide gate(s) on car as required to accommodate landing requirements Fabrication A. Cab: Series (1000, 2000, 3000, 4000, 5000, 6000) 1. Series 1000: Plywood veneer walls with clear urethane finish. 2. Series 2000: Hardwood raised panel walls with clear urethane finish. 3. Series 3000: Raised panel MDF walls finished white. 4. Series 4000: Hardwood raised panel walls with glass on one side (above handrail). 5. Series 5000: Beaded board walls painted finish. 6. Series 6000: Beaded board walls stained finish. B. Platform: Car platform constructed of 1 ¼ plywood with vinyl tile flooring. (Hardwood floor optional) C. Lighting: Lighting will consist of two (2) recessed ceiling lights operated on a separate 120 volt circuit. D. Car Gate: Each open side of the cab shall be equipped with a folding car gate with (3) clear acrylic center panels and a finish that matches the selected car finish. E. Door Interlocks: A hoistway door interlock shall be furnished for each hoistway entrance. Interlock shall prevent operation of the elevator unless doors are closed and shall prevent opening of doors when the car is not at that landing. F. Operation: Operation shall be automatic. A call station shall be furnished for each entrance. A push-button station in the car shall have one button for each level served. Car station shall also contain an emergency stop switch and alarm button. An audible alarm shall be furnished on top of car. G. Guide Rails: Steel rails shall be furnished to guide the car. Guide rails shall be mounted to the floor slab and hoistway wall with steel brackets. H. Power Unit: Machine shall be 1:2 roped hydraulic type consisting of a positive displacement, submersible pump, motor, oil reservoir and hydraulic control valve. I. Carriage: Carriage shall be attached to the car platform on the guide rail side of the car. Instantaneous broken cable device shall be provided on the carriage. J. Electric Supply: Shall be 220 volt, single phase 25 amps. (with Neutral and a Ground) K. Controller: A UL listed microprocessor based controller located in the machine room. Single call, push-button automatic operation shall be provided. Automatic cab lighting as per ANSI A CODE shall be provided. The controller shall be equipped with emergency stand-by batteries which lowers the elevator to the lowest landing in the event of power failure. Disconnects provided in the controller cabinet Performance A. Rated load 750 pound capacity. (950 pound capacity available upon request) B. Nominal travel speed of 40 feet per minute Part 3 EXECUTE 3.01 Installation A. Coordinate work with general contractor. B. Wiring the unit shall be done as part of work of this section, a 25 amp circuit with neutral and ground required. C. The installation of the elevator shall be done in accordance with the approval plans and specifications and manufacturers installation instructions. Warranty Policy Warranty The customer warranty of a JT Lawrence & Co's Elevator is as follows: JT Lawrence & Co. (the "Company") warrants to the original consumer purchaser of a JT Lawrence & Co. elevator that the Company will repair or exchange, at its option, any part of the elevator that fails, by reason of defective JT Lawrence & Co. material or workmanship, within two (2) years from the date of purchase.* Special Provisions This warranty does not cover: Labor and service charges incurred in the removal and replacement of any parts covered by this warranty. It is understood that the labor and service charges incurred in removal and replacement of parts may be covered for a certain period of time by the installer and mutually agreed upon by the owner of the elevator. Damage to parts caused by accident, improper storage or handling or misuse: the Company's obligation under this warranty is strictly and exclusively limited to the repair or exchange of parts that so failed within the applicable warranty period, and the Company assumes no responsibility for any other expenses or damages, including incidental and consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. No person or company is authorized to change or extend the terms of this warranty in any manner. To obtain warranty service you must promptly notify the JT Lawrence & Co. distributor from whom the elevator was purchased. This notice must be given within the warranty period. NOTE: Any alterations to the equipment without written authorization by the JT Lawrence & Co. will void the warranty. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. *This warranty does not apply to light bulbs, oil seals, car panels or uninterruptible power supply (UPS) La Porte Road Brownsville, CA Contact: Jerry Lawrence Toll Free: Fax: Website:
Introduction. Disclaimer. Table of contents
Updated July 18, 2012 Introduction The Cambridge Elevating Limited-Use / Limited-Application Elevator is designed to service schools, libraries, low rise, low occupancy commercial buildings, churches and
More informationSECTION HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS
SECTION 14 20 10 HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS PART 1 - GENERAL 1.1 CONDITIONS AND REQUIREMENTS A. The General Conditions, Supplementary Conditions, and Division 01 General Requirements
More informationELVORON LU/LA ELEVATOR
Creating An Accessible World ELVORON LU/LA ELEVATOR DESIGN AND PLANNING GUIDE www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site
More informationResidential Elevators
Accessibility & to Luxury Everything in Between Residential Elevators Our Message to Homeowners Dear Homeowner, Smart consumers know quality counts. So it s not surprising that discriminating homeowners
More informationResidential Elevator Design Guide
Residential Elevator Design Guide All Models - Elmira, Heritage & Cambrian 1261 Industrial Rd Cambridge, ON N3H 4W3 (p) 1.800.265.3579 (p) 519.653.4222 (fl 519.653.9927 www.cambridgeelevating.com Table
More informationLimited Use/Limited Application Elevator DESIGN GUIDE. ASME A17.1, Part V, Section 5.2. LU/LA Hydraulic Drive. symmetryelevator.com
Limited Use/Limited Application Elevator DESIGN GUIDE ASME A17.1, Part V, Section 5.2 LU/LA Hydraulic Drive symmetryelevator.com 877.375.1428 Table of Contents Elevation Limited Use/Limited Application
More informationElevating your standard of living
Elevating your standard of living March 2015 WELCOME TO REI Dear Prospective Client, I would like to personally thank you for considering Residential Elevators, Inc. (REI) for your home elevator purchase.
More informationBeautifully Crafted, Expertly Engineered, Thoughtfully Constructed
Symmetry Residential Home Elevator Systems Table of Contents Component Identification...3 Equipment for Symmetry Residential...5 Typical Hoistway Options...8 Typical Hoistway Construction...11 Typical
More informationSavaria Infinity Home Elevator. about Savaria. additional infinity options. t h E u lt i m at E q u i E t, S m o ot h r i d E. infinity cab FEaturES
E xc E p t i o n a l ta n d a r d F E at u r E 2 stops with up to 10' of travel (up to 50' optional) 750 lb, 950 lb or 1000 lb rated capacity 36" x 48", 36" x 54" or 36" x 60" cab size 80" or 84" cab height
More informationSavaria Eclipse Home Elevator
Savaria Eclipse Home Elevator Luxury and convenience customized for you About Savaria In business for over 30 years, Savaria designs, engineers and manufactures products to help people gain personal mobility.
More informationSpecification for MRL Passenger Elevators
Specification for MRL Passenger Elevators Part 1 General 1.1 Description A. This specification is intended to cover the complete furnishing and installing of one MRL passenger elevator as manufactured
More informationINCLINATOR ELEVETTE HOME ELEVATOR. America s most customizable brand
INCLINATOR ELEVETTE HOME ELEVATOR America s most customizable brand An elevator in your home is a matter of convenience. A home elevator makes it easier for people and items to move from floor to floor.
More informationVPL-3200B Residential Vertical Platform Lift Technical Specifications
Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:
More informationINTRODUCTION DEM RESIDENTIAL PLANNING GUIDE
INTRODUCTION Delaware Elevator, Inc is a family owned full service elevator company, that was established in 1946 with roots dating back to the early 1930 s. Our corporate office is located in Salisbury,
More informationRevision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd
RAM ELEVATORS Elevator Electrical Planning Guide This guide is intended for people with an understanding of electricity. If you are not, please consult a licensed electrician as errors in application of
More informationYour dream home deserves a dream elevator.
Gearless traction technology from Savaria provides an exceptionally quiet ride for the occupants and silence for the surrounding home area. A stable, smooth ride with soft start and stop can be configured
More informationSPECIFICATIONS. Part 1- General
1.1 SCOPE Part 1- General To furnish all labor, materials and equipment necessary or required to fully complete the installation of the elevator as shown on the drawings and specifications. This suggested
More informationV1504 VERTICAL PLATFORM LIFT PLANNING GUIDE
V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: ASME A17.1 ASME A18.1 CAN/CSA B355 17-m06-2011 Part No. 000690 Copyright 2011 Savaria Corporation All rights reserved. Printed in Canada Purpose
More informationYou dream it. We build it. ELEVATORS
You dream it. We build it. ELEVATORS RAM can help you tailor your Crystal Elevator to be a focal point in your home with stunning architectural features or it can be tucked away for seamless and simple
More informationSavaria Eclipse Home Elevator OPTIONS. In business for over 30 years, Savaria designs,
S TA N D A R D S P E C I F I C AT I O N S 750 lb capacity Running speed 40 ft/min Fully automatic operation 2 hp motor Wide stable rail design Modular rail sections for quick install Energy efficient variable
More information1. Vertical reciprocating conveyor, Hydraulic straddle VRC.
PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related
More informationSECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?
SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum
More informationModel 5200 Cargo Lift Installation and Operation Manual
Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household
More informationSECTION INCLINE WHEELCHAIR LIFT PART 1 GENERAL 1.1 SECTION INCLUDES. A. Stair wheel chair lift. 1.2 RELATED SECTIONS
SECTION 14 42 13 - INCLINE WHEELCHAIR LIFT PART 1 GENERAL 1.1 SECTION INCLUDES A. Stair wheel chair lift. 1.2 RELATED SECTIONS A. Section 03 30 00 - Cast-In-Place Concrete: Anchor placement in concrete.
More informationSECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS
SECTION 08361 RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES. A.
More informationSPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders
Welcome to the O Keeffe s Guide Specification System prepared as an aid to specify in preparing written construction documents. For specification assistance with specific product applications, please contact
More informationModel 5000 Cargo Lift Installation and Operations Manual
Model 5000 Cargo Lift Installation and Operations Manual Congratulations on the purchase of your new SpaceLift Products 5000 cargo lift system. Expect to receive many years of reliable service moving household
More informationSST-II HYDRAULIC BI-FOLD SPECIFICATIONS
PART 1 GENERAL 1.01 DESCRIPTION A. General 1. Furnish SST-II Hydraulic Bi-Fold System complete from one manufacturer. Provide all labor, materials, tools and equipment to furnish the SST-II Bi-Fold System
More informationF-SERIES: F SPECIFICATIONS Four-Fold Door Systems
Version 5.22.13 F-SERIES: F100-600 SPECIFICATIONS Four-Fold Door Systems OPTIONS ARE IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT. CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.
More informationLTH3700, HOLLOW METAL SLIDING FIRE DOOR
LTH3700, HOLLOW METAL SLIDING FIRE DOOR Consult Manufacturer for additional options or modifications PART 1-GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General
More informationFORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual
FORM HEADWALL (floating) Installation Manual FORM HEADWALL (floating) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated
More informationHD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator
HORTON AUTOMATICS - ARCHITECTURAL SPECIFICATIONS, 1/2008 HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator DIVISION 08 - OPENINGS SECTION 08 42 29.33 SWINGING AUTOMATIC
More informationSECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM
Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING
More informationARCHITECTURAL SPECIFICATIONS
1 B4.1 Surface Applied Page 1 of 6, June 17 DIVISION 08 - OPENINGS SECTION 08 71 13 POWER DOOR OPERATORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements.
More informationSeries - 1
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationFORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual
FORM HEADWALL (floor mount) Installation Manual FORM HEADWALL (floor mount) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated
More informationModel 5200 Cargo Lift Installation and Operation Manual
Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household
More informationTelecommunication Spaces
Telecommunication Spaces October 19, 2016 Page 1 Revision History Telecommunication Spaces Standard Effective Date Email Version Contact Phone OIT-TS strevena@csustan.edu 1.0 Stan Trevena 209.667.3137
More informationSECTION BASIC ELECTRICAL REQUIREMENTS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions, apply to work of this section. 1.2 SUMMARY A. This section specifies
More informationUNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION
PART 1 - GENERAL 1.01 Elevator manufacturer to provide equipment and installation warranty and maintenance services for at least one year after acceptance. This requires routine monthly inspection, emergency
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 142400 - HYDRAULIC ELEVATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationG. UNDERWRITERS LABORATORY, INC.: 1. UL 325: Electrical Door, Drapery, Gate, Louver, and Window Operators and Systems
B6.0 DIVISION 8 - DOORS AND WINDOWS SECTION 08460 - AUTOMATIC ENTRANCE DOORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and titles
More informationFreight Elevator Series GFM-T
Freight Elevator Series GFM-T Mitsubishi Freight Elevators Can Improve our Goods-Handling Ability Elevator Selection 1. Rated capacity and car size What is the maximum weight or size of goods to be transported
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS PRODUCT OVERVIEW: Top Supported Center Stack Paired Panels Manually Operated Maximum Opening Height: 10'2 [3.1] Maximum Opening Width: Unlimited Select for Special Needs: Use
More informationPlanning Guide (Imperial)
P.A.L.TM VERTICAL PLATFORM LIFT Planning Guide (Imperial) For Vertical Platform Lifts P.A.L. - S (Unenclosed or Hoistway Models) P.A.L. - EN (Fully Enclosed Models) Applicable Codes: ASME A18.1 CAN/CSA
More informationSECTION OUTLET, PULL, AND JUNCTION BOXES
SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:
More informationSeries 3000 Pocket Doors
Series 3000 Pocket Doors Introduction: The following three (3) part specification offers the Standard and Optional features for the Series 3000 Pocket Doors. The yellow highlighted areas in the specification
More informationSECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS
SECTION 08211 VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division I Specification
More information300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP
www.burcam.com 2190 Dagenais Blvd. West TEL : 514.337.4415 LAVAL (QUEBEC) FAX : 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during
More informationFoldingAccess Series Aluminum Folding Door System
HORTON AUTOMATICS - ARCHITECTURAL SPECIFICATIONS, 1/2008 FoldingAccess Series 4-4200 Aluminum Folding Door System DIVISION 08 - OPENINGS SECTION 08 42 29.13 FOLDING AUTOMATIC ENTRANCES Specifier Note:
More informationWine Storage Models 427G and 427RG Design Guide
Wine Storage Models 427G and 427RG Design Guide Contents 3 Wine Storage 4 Specifications 6 Custom Panels 10 Full-Scale Template 11 Warranty Features and specifications are subject to change at any time
More informationGerber M Series Site Requirements
Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL PART 1.1 SECTION INCLUDES A. Overhead doors. B. Bi-fold doors. PART 1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete: Prepared opening
More informationANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists
SECTION 412213- BRIDGE CRANES Part 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION CLIMBING WALLS
SECTION 13120-1 PART 1 - GENERAL 1.1 SUMMARY A. This section includes the following: 1. Custom Climbing Wall. B. Related Sections 1. Section Structural Steel 2. Section Rough Carpentry 3. Finishes 1.2
More information2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and frames.
PART 1: GENERAL 1.01 Summary Section Includes: 1. Electric traction Dumbwaiter system. 2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and
More informationGLASSWALL SPECIFICATIONS
GLASSWALL SPECIFICATIONS Series GL Paired, Glass Panels PRODUCT OVERVIEW: Top Supported Center Stack Paired Panels Manually Operated Maximum Opening Height: 0' 5 [3.m] Maximum Opening Width: Unlimited
More information3000 SERIES POCKET DOOR
3000 SERIES POCKET DOOR KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 3000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose
More informationINSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP
www.burcam.com 2190 Dagenais Blvd. West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
More informationSECTION SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.
More informationSECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS
SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,
More informationMaintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual
Maintenance Bypass Breaker Cabinet 90881 Series Configuration 5 Installation and Operation Manual 03/13/2012 2 755-00084-C5 R03 Copyright 2012 C&C Power, Inc. All rights reserved. C&C Power, Inc. 395 Mission
More informationSECTION INFLUENT EQUALIZATION TANK PUMPS
PART 1 GENERAL 1.01 SCOPE OF WORK A. The Contractor shall furnish and install all materials, labor and equipment to put into service the Influent Equalization Pumps in accordance with the Contract Drawings
More informationB. Polyethylene samples shall be submitted for Owner approval of color and quality.
Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and
More informationSonoran 2" Horizontal Blinds. Retail Price List
Sonoran 2" Horizontal Blinds Retail Price List Effective December 1, 2015 Terms and Conditions ORDER PROCESSING Telephone Orders Verbal orders are accepted as the dealer's responsibility. Each order will
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum
More informationDIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...
DIVISION 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN Contents 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION 13 00 60 LIST OF FIGURES... 6 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN 1. General Requirements
More informationPART 2. PRODUCTS 2.01 Traction Elevators A. Traction elevators shall be Hollister - Whitney Elevator Company equipment.
February 2012, Rev. 00 14 2000 Elevators PART 1. GENERAL 1.01 The Elevator Standards apply to a variety of conditions and types of elevators. The program statement for the project will outline preliminary
More informationSECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION
SECTION 12 31 00.4 Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION PART 1 GENERAL Summary: This Specification identifies the minimum material and construction standards
More information2000 POCKET DOOR TECHNICAL DATA
2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose
More informationELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS
ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS McGrath Industries Ltd. 2017. All rights reserved. Ed04, CJM. ELEVATORS SERVICE
More informationF.C.L. INTERIOR FINISHES CHECK LIST 2010 PRODUCT SELECTION - FLOORING GENERAL ITEMS PRODUCT SELECTION GENERAL ITEMS
INTERIOR FINISHES CHECK LIST 2010 Project: Project Number: Wil-Spec # This should not take long to go through, most questions below are listed as options, all you have to do is check off those answers
More informationN-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System
Version 5.22.13 N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITONAL
More informationSECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:
SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.
More informationARCHITECTURAL SPECIFICATIONS
1 B5.1 Surface Applied Page 1 of 6, July 10 DIVISION 08 - OPENINGS SECTION 08 71 13 POWER DOOR OPERATORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements.
More informationMODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS
MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes
More information1. Schedule For Preventative Maintenance Requirements:
Attachment A - Preventive Maintenance Services Requirements The Contractor shall provide preventative maintenance to include cleaning, adjusting, lubricating, painting, wiring, maintaining performance
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS 2190 Dagenais Blvd.West Laval (Quebec) Canada H7L 5X9 Tel. : 514.337.4415 Fax : 514.337.4029 info@burcam.com see us at www.burcam.com VERSION Z MODELS 300500 SUMP PUMPS Your pump
More informationSeries - 1
SECTION 08360 SECTIONAL OVERHEAD DOORS 591 SERIES THERMACORE INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click
More informationOPERABLE PARTITIONS. Signature
OPERABLE PARTITIONS Signature 8000 SIGNATURE 2 WHO WE ARE Moderco is an international manufacturer of Manual & Electric Operable Partitions, Accordion Doors, Glass Wall Systems, and Gymnasium Dividers.
More informationCONVENTIONAL TG-150 LM TG-20 LM OPERATOR S MANUAL GATE SERIES Slauson Avenue. Santa Fe Springs, CA (800)
M-91-16 REV. 2 AUG. 1997 OPERATOR S MANUAL CONVENTIONAL LIFTGA GATE SERIES TG-150 LM TG-20 LM 11921 Slauson Avenue. Santa Fe Springs, CA. 90670 (800) 227-4116 C MAXON Lift Corp. 1997 LIFT CORP. 11921 Slauson
More informationCountertops and Cabinets
Countertops and Cabinets 5.1 Laminated countertop has developed a bubble. Laminated countertops shall not have localized bumps or swells. Countertops not meeting the acceptable performance condition shall
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'
More informationHD-Slide Series 2001 Heavy Duty Aluminum Sliding Door System with Electric Belt Drive Operator
HORTON AUTOMATICS - ARCHITECTURAL SPECIFICATIONS, 1/2008 HD-Slide Series 2001 Heavy Duty Aluminum Sliding Door System with Electric Belt Drive Operator DIVISION 08 - OPENINGS SECTION 08 42 29.23 SLIDING
More informationOPERATING PROCEDURE NO. 310
OPERATING PROCEDURE NO. 310 Related Operating Procedures: 310A; 310B; 310C; 310D SUBJECT: Conditions of Service Issued: February 10, 2014 Revised: March 28, 2016 OBJECTIVE: To establish the rules, regulations
More information3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package
3M Intelligent Return Plus and Sorter System SL Architect/Contractor's Package 3M, 2015. All rights reserved. 3M Intelligent Return Plus and Sorter System SL Architect/Contractor's Package, 78-8129-4937-4B
More information1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.
ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 11 00 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationMETERING INSTALLATION
4.01 METERING SPECIFICATIONS METERING INSTALLATION Metering specifications will be issued to the customer by OPPD. Metering specifications are required before any work is started on all new wiring or additions
More informationC60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
For more information, visit www.247technology.com/on-line-ups/c60-standby-ups C60 Standby UPS 800VA Models User & Installation Manual 2015. All rights reserved. (Rev 6/23/15) Table of Contents Package
More informationCustomer Owned and Constructed Transformer Alcove
Electric Service Requirements Customer Owned and Constructed Transformer Alcove Engineering Specification December 2014 Powering forward. Together. GAF 1212-14 Page 1 TABLE OF CONTENTS 1. PURPOSE... 2
More informationPower Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features
DESIGN CRITERIA FOR STANDARD CONSTRUCTION: These standard design elements of the P.E.I. Power Equipment Center are utilized to meet the following design criteria per ASCE 7-05 as adopted by the IBC (International
More informationMaintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual
Maintenance Bypass Breaker Cabinet 90881 Series Configuration 2 Installation and Operation Manual 03/13/2012 2 755-00084-C2 R03 Copyright 2012 C&C Power, Inc. All rights reserved. C&C Power, Inc. 395 Mission
More informationProduct Guide Specification
VT Industries, Inc. November 2012 1000 Industrial Park PO Box 490 Holstein, Iowa 51025 Toll Free (800) 827-1615 Phone (712) 368-4381 Fax (712) 368-4111 Website www.vtindustries.com E-mail door_info@vtindustries.com
More informationEDGEWATER, FLORIDA JUNE 14, 2010
SECTION 12 2413 - ROLLER WINDOW SHADES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationThis guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.
SECTION 14651 FREE STANDING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and industrial
More informationA. Submit the following in addition to the standard requirements.
SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,
More informationINSTALLATION MANUAL & Warranty Information
ONE PIECE SHOWER STALLS INSTALLATION MANUAL & Warranty Information 255 Hutchings Street Winnipeg, Manitoba R2X 2R4 - Phone: (204) 633-6122 - Fax: (204) 632-4854 Toll Free Phone: 1-800-665-7531 - Toll Free
More informationWARRANTY REGISTRATION Please complete your warranty registration to properly validate your warranty. Register your product online at: www.onlinewarranty.net LIMITED CONDITIONAL WARRANTY* Backyard Storage