CONCRETE CURB AND GUTTER
|
|
- Pierce Phelps
- 5 years ago
- Views:
Transcription
1
2 USE APWA STD. PLAN 205 TYPE A. ADJUST DIMENSIONS FOR A 2% SLOPE. 6" 6" 1'-4" 3" NOTES: 1. FLATTEN GUTTERS AT ADA RAMP LOCATIONS. GUTTERSLOPES MAY BE REDUCED BETWEEN RAMPS AS WELL AS AT CURB RAMPS WHERE MORE THAN ONE RAMP WILL BE CONSTRUCTED AT A CORNER. 1" 2. USE APWA CLASS 3000 CONCRETE OR APPROVED EQUAL OR BETTER. 3. MEASURE CURB HEIGHT FROM THE GUTTER. 4-INCH MIN. UNTREATED BASE COURSE COMPACTION: 96% MOD. PROCTOR 6" 8" HIGH BACK - CURB & GUTTER TRUCK APRON No. 4 5 FEET MAX O.C. PAVEMENT SINGLE CURB - LOW 3" PAVEMENT 4. DO NOT USE SINGLE CURB OR MOUNTABLE CURB AS GUTTERS. 5. THE CITY ENGINEER MAY APPROVE SPECIFIC DESIGNS WHEN VARIATIONS FROM THE STANDARDS ARE NEEDED DUE TO SITE CONDITIONS, UTILITY, OR TOPOGRAPHICAL CONSTRAINTS. ANY VARIANT OF THESE DETAILS MUST BE BASED UPON A DESIGN STAMPED BY A UTAH LICENSED PROFESSIONAL CIVIL ENGINEER. 1'-4" GROUND 10" 7" 10" 8" PAVEMENT 3-INCH MIN. UNTREATED BASE COURSE COMPACTION: 96% MOD. PROCTOR 4-INCH MIN. UNTREATED BASE COURSE 96% MOD. PROCTOR COMPACTION SINGLE CURB MOUNTABLE CURB (MEDIANS & PARKING LOTS ONLY) (ROUNDABOUT ONLY) STANDARD DETAIL TITLE CONCRETE CURB AND GUTTER ST-2
3 TRANSITION WIDTH VARIES (2 FOOT MIN.) SIDEWALK PARK STRIP S=4H:1V MIN DRIVEWAY APPROACH EXPANSION JOINTS (TYP.) S=2% S=10H:1V MAX CONCRETE THICKNESS, T NOTES: 1. CHAMFER ALL CONCRETE EDGE WITH MIN. RADIUS OF 0.5 INCHES. 2. PROVIDE 0.5 INCH EXPANSION JOINT BETWEEN DRVEWAY APRON AND CURB, DRIVEWAY CENTER LINE WHEN THE DRIVEWAY IS WIDER THAN 10 FEET AND SIDEWALK SEGMENTS. EXTEND THE EXPANSION JOINT 1 INCH BELOW THE CONCRETE AND PLACE IT FLUSH WITH THE SURFACE. 3. PLACE 6 INCH UNTREATED BASE(UTBC) UNDER CURB, GUTTER AND SIDEWALK. COMPACT THE UTBC TO 96% MODIFIED PROCTOR. 4. DO NOT EXCEED 15% SLOPE CHANGE FROM THE GUTTER TO THE DRIVEWAY SLOPE. REDUCE DRIVEWAY SLOPE TO MEET REQUIREMENT. 5. SET FRONT EDGE OF SIDEWALK 2% HIGHER THAN TOP OF BACK OF CURB (MIN. 1 INCH). 6. THE CITY ENGINEER MAY APPROVE SPECIFIC DESIGNS WHEN VARIATIONS FROM THE STANDARDS ARE NEEDED DUE TO SITE CONDITIONS, UTILITY, OR TOPOGRAPHICAL CONSTRAINTS. ANY VARIANT OF THESE DETAILS MUST BE BASED UPON A DESIGN STAMPED BY A UTAH LICENSED PROFESSIONAL CIVIL ENGINEER. DRIVEWAY HALF WIDTH, W DRIVEWAY (TYPICAL) 2% FLOWLINE LIP OF GUTTER PATH MATERIAL: ASPHALT THICKNESS: 3-INCHES UTBC: 8-INCH SIDEWALK MATERIAL: CONCRETE THICKNESS: 5-INCHES MIN. UTBC: 6-INCH MIN. DRIVEWAY CONCRETE MINIMUM THICKNESS RESIDENTIAL = 6 INCHES INDUSTRIAL/COMMERCIAL/INSTITUTIONAL =8 INCHES MINIMUM WIDTH = 10 FEET MAXIMUM WIDTH = 30 FEET - UNLESS SHOWN ON AN APPROVED SITE PLAN EXPANSION JOINTS 4" MIN. UNTREATED BASE COURSE DRIVEWAY CROSS SECTION (TYPICAL) STANDARD DETAIL FLARE DRIVEWAY ST-3
4
5
6 3' MIN. 1.0' 5.5' STANDARD DETAIL TITLE TYPICAL UTILITY PLACEMENT ST-6B
7 115' to 130' 10.0' 6.0' 8.0' 12.0' 12.0' 14.0' 12.0' 12.0' 8.0' 6.0' 6.0' 80.0' 5.0' 7.5' 8.0' 11.0' 12.0' 11.0' 8.0' 7.5' 5.0' STANDARD DETAIL TITLE TYPICAL STREET CROSS-SECTIONS Part 1 ST-7A
8 66.0' 5.0' 6.5' 8.0' 11.0' 11.0' 8.0' 6.5' 5.0' 55.0' 5.0' 7.5' ' 5.0' 52' 5.0' 6' 1 1 6' 5.0' STANDARD DETAIL TITLE TYPICAL STREET CROSS-SECTIONS Part 2 ST-7B
9
10 STANDARD POST CAP ALUMINUM POWDER COATED SATIN BLACK STAINLESS STEEL RIVETS (TYPICAL) Street Name 1700 W 38" x 9" ALUMINUM SIGN W/ SUPER ENGINEERING GRADE (SEG) REFLECTIVE SHEETING 6" STREET NAME LETTERING W/ 3" COORDINATE LETTERING UPPER/LOWER CASE COMBINATION IN HELVETICA NARROW BOLD FONT STREET DESIGNATION TO BE PROVIDED BY CITY STOP U-BOLT SIGN MOUNTING CLAMPS SIGN POST: ROUND 2 3/8" O.D. (0.65 WALL) GALVANIZED STEEL POWDER COATED SATIN BLACK 8'-0" MIN FOR STREET NAME SIGNS 7'-0" MIN DECORATIVE SLIP BASE W/ SET SCREWS ALUMINUM POWDER COATED SATIN BLACK NOTES: 1. SECURE CITY'S APPROVAL OF SIGN FORMAT AND INSTALLATION. V-LOCK MODEL 23VR2 TYPE BREAK-AWAY ANCHOR OR APPROVED EQUAL 2. INSTALL THE EDGE OF THE SIGN TWO FEET FROM THE VERTICAL EXTENSION OF THE BACK OF CURB AS NEAR AS POSSIBLE TO THE APPROACH CURB POINT OF CURVATURE. SIGNS SHOULD NOT OVERHANG SIDEWALK OR CURB & GUTTER. 3. ALL TRAFFIC SIGNS (STOP, SPEED, ETC.) SHALL BE 7' MINIMUM FROM GROUND TO BOTTOM OF SIGN AND SHALL CONFORM TO THE REQUIREMENTS OF THE "UTAH MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES." 4. POSTS SHALL BE MANUFACTURED FROM ASTM A-513 STEEL - 55,000 p.s.i. MIN YIELD AND 70,000 p.s.i. MIN TENSILE STRENGTH. 5. PUBLIC ROADS SHALL BE SIGNED IN GREEN, AND PRIVATELY OWNED AND MAINTAINED ROADS IN BLUE. 6. USE PROPER ABBREVIATIONS FOR STREET NAMES PER SALT LAKE COUNTY ADDRESSING STANDARDS SECTION 3 "STANDARDIZATION." STANDARD DETAIL TITLE SIGN POST ST-9
Entellus 75 NORTH STREET MERRILL SHERIFF CONSTRUCTION. 181 North 200 West, Suite #4. Bountiful, UT Phone
Entllus DUMPSTER PAD AND REPLACE WITH NEW BETWEEN THESE TWO POINTS SAWCUT ALONG DEMO LINE REMOVE PARKING SPOTS CURB, GUTTER, ASPHALT AND LANDSCAPING, WITHIN HATCHED AREA FOR NEW ADDITION CURB & GUTTER
More informationSign & Post Installation. Standard Specifications and Standard Drawings. July 2017 Edition
Standard Specifications Sign & Post Installation Utility Services Department 500 George Street North, Peterborough, Ontario, K9H 3R9 Transportation Division Telephone: 705-742-7771 Fax: 705-876-4621 Sign
More informationDepartment of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION
Department of Building and Zoning Approaches and Sidewalks for ONE AND TWO FAMILY CONSTRUCTION GENERAL ITEMS SUBGRADE Prior to pouring concrete all subgrades must be wetted and compacted. All formwork
More informationUNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS
, NEVADA YEAR 2015 REVISIONS SECTION TITLE AND REVISIONS SUMMARY EFFECTIVE DATE 217.S2 "Residential Curb and Gutter, R-Type" - New drawing to accommodate ADA requirements. 223 "Residential Driveway" -
More informationGENERAL NOTES ROADWAY CONSTRUCTION RD0001-1A ISSUED:2017 REVISED: --
ROADWAY CONSTRUCTION NOTES 1. ALL RIGHT-OF-WAY OTHER THAN ROADWAY AREAS SHALL BE SODDED. ALL SLOPE STEEPER THAN 6:1 SHALL REQUIRE SODDING. THE CITY RESERVES THE RIGHT TO REQUIRE SODDING IN SPECIAL AREAS
More informationPART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER
PART 7 COMMUNICATIONS, LIGHTING, TRAFFIC CONTROL, POWER COMMUNICATIONS LIGHTING Street Lighting Plan 710 Riser... 287 730 Collar for street light pole... 289 731 Pull box... 291 732 Trench for street light
More informationSTREET IMPROVEMENTS (Refer to Title 18, chapter entitled "STREETS" of the Layton Municipal Code.)
STREET IMPROVEMENTS (Refer to Title 18, chapter 18.24 entitled "STREETS" of the Layton Municipal Code.) I. Street widths STREET TYPE (ALL MEASUREMENTS IN FEET) ROW WIDTH LAYTON CITY STANDARD STREET SECTIONS
More informationThe Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.
The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains
More informationD-1 THE CITY OF HARRISBURG 1 1/2" MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2" MIN. ID-2 BINDER COARSE
EXISTING STREET SURFACE 1 1/2" MIN. ID-2 BINDER COARSE 1 1/2" MIN. ID-2 WEARING COARSE AC-20 SEALER (ALL AROUND) 8" CLASS A P.C. CONCRETE SAW CUT TOP OF CONCRETE SHALL MEET SURFACE OF EXISTING CONCRETE.
More informationCITY OF ANN ARBOR, MICHIGAN Public Services Area/Project Management Unit 301 E. Huron Street P.O. Box 8647, Ann Arbor, Michigan 48107
CITY OF ANN ARBOR, MICHIGAN Public Services Area/Project Management Unit 301 E. Huron Street P.O. Box 8647, Ann Arbor, Michigan 48107 Web: www.a2gov.org Printed on recycled paper May 17, 2016 Subject:
More informationThe Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.
The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains
More informationThe Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.
The Most Advanced Name in Water Management Solutions TM The most cost-effective slotted and trench surface drain systems. A sensible alternative to metal and concrete Since 1987, Duraslot surface drains
More informationConstruct each curb ramp using Type A1 Use curb ramps with flared sides at locations with wide sidewalks. NOTES Construct each curb ramp using Type A2 Construct each curb ramp using Type A1 PERPENDICULAR
More informationCurb Ramps [ 4.7.3] [ 4.7.2; 4.8.2; 4.1.6(3)(a)] [ 4.3.7] ADA Accessibility Survey Instructions Curb Ramps Page 1 of 6
: Curb Ramps 1 [ 4.7.3] Only measure the width of the ramp section of the curb ramp (labeled ramp to the right). The ramp section of a curb ramp is also known as the ramp run. If the curb ramp has flared
More informationCITY OF LAKEVILLE STANDARD SPECIFICATIONS FOR STREET CONSTRUCTION FOR PUBLIC USE TO BE MAINTAINED BY THE CITY SECTION 4
CITY OF LAKEVILLE STANDARD SPECIFICATIONS FOR STREET CONSTRUCTION FOR PUBLIC USE TO BE MAINTAINED BY THE CITY SECTION 4 STREET CONSTRUCTION INDEX 1.00 SCOPE 2.00 SPECIFICATION REFERENCE 3.00 SUBGRADE PREPARATION
More informationSECTION CURB RAMPS AND OTHER MINOR CONCRETE FACILITIES. Part 1 - General Work Included Related Requirements...
SECTION 02530 CURB RAMPS AND OTHER MINOR CONCRETE FACILITIES CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Inspection And Tests... 1 1.04 Quality Assurance...
More informationIntro. ADA Operations Contact Info
Intro ADA Operations Contact Info Todd Grugel ph: 651-366-3531 email: todd.grugel@state.mn.us Joe Zilka ph: 651-366-3311 email: joseph.zilka@state.mn.us Harvey Unruh ph: 651-216-2912 email: harvey.unruh@state.mn.us
More informationISSUED: 1/16/15 REVISION: 1.0 REVISION: STANDARD DETAIL COMBINATION 6'' CURB & GUTTER CITY OF FALLS CHURCH VA PUBLIC WORKS
ISSUED: 1/16/15 1.0 COMBINATION 6'' CURB & GUTTER ISSUED: 1/16/15 1.0 SIDEWALK DETAIL ISSUED: 7/7/15 1.0 VALLEY GUTTER ISSUED: 2/11/16 1.0 BRICK PAVER SIDEWALK DETAIL 1''=1' WIDTH VARIES SEE SHEET 2 MIN.
More informationFOR PROJECTS INITIATED AFTER FEBRUARY 1, 2010 REVISION 3 ITEM 530 CONCRETE CURB, GUTTER, CURB AND GUTTER SIDEWALKS AND DRIVEWAYS
AFTER FEBRUARY 1, 2010 ITEM 530 CONCRETE CURB, GUTTER, CURB AND GUTTER SIDEWALKS AND DRIVEWAYS 530.1 Description. This item shall govern for curb, gutter, combined curb and gutter, sidewalks and/or driveways,
More informationITEM 6 CONCRETE CURBS, GUTTERS, AND SIDEWALKS
ITEM 6 CONCRETE CURBS, GUTTERS, AND SIDEWALKS 6.1 DESCRIPTION This work shall consist of constructing curbs, gutters, sidewalks, ramps, local depressions and driveways of the form and dimensions shown
More informationPERMEABLE PATH PAVING
SAWCUT CONTROL JOINT: 1 WIDE x 1" DEEP SIGN B: R5-1 24" (1 REQ'D) SIGN C: R5-11 24"x 1 (1 REQ'D) PADOT STANDARD SIGNAGE INSTALL PER PADOT SPECIFICATIONS. HIGH INTENSITY PRISMATIC SIGN ON 0.080" THICK ALUMINUM
More information3-6" S101 INCHES[MILLIMETERS] 5/8"Ø 304 STAINLESS STEEL BAR 5/8"Ø 6063 ALUMINUM BAR 5/8"Ø 360 BRASS BAR 5/8"Ø 385 ARCH BRONZE BAR 5/8"Ø BAR BEND
WAGNER #S101 BRACKET SADDLE 2 2" 1 1 1 4" (1.66 O.D.) GALV. STEEL PIPE GRAB RAIL. FASTENED TO BRACKET SADDLE W/ 2 - S.S. SELF TAPPING SCREWS. WAGNER #R140 5 8" BRACKET ARM WELDED TO EACH POST AND BRACKET
More informationCW 3240 RENEWAL OF EXISTING CURBS TABLE OF CONTENTS
December 2012 CW 3240 RENEWAL OF EXISTING CURBS TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications... 1 1.4 Referenced Standard
More informationSPECIAL PROVISIONS - SP2014 BOOK Page 1 October 8, 2013
SPECIAL PROVISIONS - SP2014 BOOK Page 1 S-1 (2104) REMOVE AND REPLACE BITUMINOUS PAVEMENT (ADA) Always include SP2014-119 (PLANT MIXED ASPHALT PAVEMENT) or SP2014-121 (PLANT MIXED ASPHALT PAVEMENT FOR
More informationSECTION 3200 CONCRETE CURB AND GUTTER
PART 1 GENERAL 1.01 Section Summary SECTION 3200 CONCRETE CURB AND GUTTER CONCRETE CURB AND GUTTER A. Construction of concrete curb and gutter. 1.02 Related Sections A. Section 2900 Aggregate Base Course.
More information(D) Surface Slope Bituminous patch in front of the truncated domes must not exceed 5% measured perpendicular to the flow line or edge of roadway.
Last Revision by CO Special Provisions: 09/14/18 Page 1 S-1 (2104) REMOVE AND REPLACE BITUMINOUS PAVEMENT (ADA) Always include SP2018-143 ((2360) PLANT MIXED ASPHALT PAVEMENT (MSCR)) when using this writeup.
More informationConstruction Overview. Section 5 Construction Considerations. Curb Ramp Construction. Curb Ramp Construction. Overview.
Construction Overview Section 5 Construction Considerations Fall, 2017 Ann Johnson, PE Services Brady Rutman, SRF Consulting Group Overview Pedestrian Standard Plans Grade Breaks s Removals Curb & Gutter
More informationSITE ACCESSIBILITY AND PARKING
SITE ACCESSIBILITY AND PARKING The purpose of this handout is to clarify the requirements of site accessibility under the 2013 California Building Codes, Specifically, Section 11B. Each lot or parking
More informationCITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION
INTRODUCTION CITY OF DANA POINT COMMUNITY DEVELOPMENT, BUILDING AND SAFETY 33282 Golden Lantern, Suite 209 Dana Point, CA 92629 949 248-3594 www.danapoint.org SITE ACCESSIBILITY AND PARKING B103 SITE 2013
More informationCHAPTER 2. Restricted Residential ½ Street** Design Speed 25 MPH 25 MPH 25 MPH 25 MPH 40 MPH 50 MPH 55 MPH
CHAPTER 2 201 ROADS 201.1 General This section is to assist the designer in determining what is needed for the design of roads in public rights-of-way. For these standards, the terms used are: Restricted
More informationSection 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1
Section 7 Roadway GENERAL REQUIREMENTS...7-1 I. TYPICAL SECTION...7-1 7.1 LANE WIDTHS...7-1 7.2 SHOULDER WIDTHS...7-1 7.3 CROSS SLOPE...7-2 7.4 CURB AND UNDERDRAINS...7-2 7.5 SIDEWALKS AND DRIVEWAYS...7-2
More informationSECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS
SECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS Section Page SECTION 14 RESTORATION OF SURFACES... 14.1 14-1 GENERAL... 14.1 14-2 PRIVATE ROADS... 14.1 14-3 STREETS AND PARKING LOTS... 14.1 14-3.01
More informationSMALL CELL DESIGN GUIDELINES
Section 1: Collocations on Existing Wireless Support Structures (Type I and II Requests) 1.1 Collocations Encouraged. The collocation of wireless facilities on existing support structures engineered to
More informationSECTION A-A NTS. Figure 4.1 Alternative Flow Dispersal Trench NOTES:
Figure 4.1 Alternative Flow Dispersal Trench NOTES: galvanized bolts 2" x 12" pressure treated grade board 2" x 2" notches 18" O.C. *20% max 12" min. 36" max 1' - 6" min *20% max 4" x 4" support post clean
More informationPART 5 WATER SYSTEMS
PART 5 WATER SYSTEMS Abbreviations and Symbols Plan 501 Abbreviations and symbols for water... 205 Concrete Boxes and Hardware 502 27" Frame and cover... 207 503 38" Frame and cover... 209 505 Concrete
More informationSPECIFICATIONS (unless noted otherwise)
2" 150F SYSTEM PROFILE 5 7 8 " NOM. CARRIER SPLICE SEE DETAIL B1.4 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 DETAIL 'A' TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 1 VERTICAL
More informationSECTION 26 - COLD PLANE ASPHALT CONCRETE PAVEMENT TABLE OF CONTENTS
SECTION 26 - COLD PLANE ASPHALT CONCRETE PAVEMENT TABLE OF CONTENTS Section Page 26-1 GENERAL... 26.1 26-2 PAVEMENT KEYCUTTING... 26.1 26-3 PAVEMENT PLANING... 26.2 26-4 PLANED PAVEMENT CONFORMS... 26.3
More informationSidewalk Regulations. Table of Contents
Sidewalk Regulations Table of Contents Section 1. Purpose and Intent... 2 Section 2. Pedestrian Sidewalk, Driveway Apron and Curb and Guttering Requirements... 2 Section 3. Sidewalk Provision Criteria...
More informationBADGETT STADIUM FACILITY
FACILITY PROJECT TEAM: VICINITY MAP NTS OWNER - NAME: ADDRESS: 3667 MAIN STREET. COLLEGE PARK,GA. 30337 CONTACT PERSON: EMANUEL RAINEY, DIRECTOR TEL. #: 404-669-3767 ENGINEER - NAME: ENTERPRISES,INC. ADDRESS:
More informationHORIZON MEADOWS MINOR DEVELOPMENT PERMIT AMENDMENT LOT 1, BLOCK 3 OF HORIZON MEADOWS SUBDIVISION FILING NO. 1
HORIZON MEADOWS MINOR DEVELOPMENT PERMIT AMENDMENT LOT 1, BLOCK 3 OF HORIZON MEADOWS SUBDIVISION FILING NO. 1 MDP 201-033A SAWCUT ASPHALT 5' NORTH OF EXIST. CURB OWLINE 31' SAWCUT ASPHALT 2' NORTH OF EXIST.
More informationSection CONCRETE SIDEWALKS. 1. Payment for concrete sidewalks is on square foot basis.
PART 1 GENERAL 1.01 SUMMARY A. This Section includes the following: Section 02775 1. Reinforced concrete sidewalks. 2. Wheelchair Ramps. 1.02 MEASUREMENT AND PAYMENT A. Unit Prices. 1. Payment for concrete
More informationRESIDENTIAL DRIVEW AY APPROACH JOB NO. SHEET NO. DATE MARCH 2015 OF 2% MAX VARIES: 1% MIN TO 7% MAX EXISTING DRIVE EXIST. ROW PROPOSED 6" WALK
01-APR-2015 08:59 4 (TYP) EXISTING DRIVE A 4 (TYP) ROW = I:\MSV8i\Plotting\piblack.ptb V:\201001\\C\8x11_Howell_Det\pvg_det01_8x11_P01.dgn TIME = EX. PROPOSED 6" WALK SIDEWALK WALK EX. DRIVEWAY 4 WALK
More informationSection 13. Guidelines for the Design of Ground Mounted Sign Supports
Section 13 BDC11MR-04 13.1 Introduction Highway signs fall into two main categories, which are subdivided as follows: 1. Overhead Signs a. Sign Bridge Structures (GO) b. Sign Cantilever Structures (GO)
More informationFinal Report 2014 Addendum
Final Report 2014 Addendum Supplemental ADA Transition Plan Inventory of Public ROW Facilities Prepared by: August 2014 Table of Contents Executive Summary...1 Introduction...2 Inventory Methodology...2
More informationSECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS
SECTION 12 STANDARDS FOR CONSTRUCTION PLANS AND SPECIFICATIONS 12.1 The subdivider shall construct and install the improvements in accordance with the County's Standards for Construction Plans and Specifications
More informationDARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
PART 1 DESIGN DIRECTIVES 1.1 GENERAL SECTION 02801 MISCELLANEOUS SITE DETAILS A. This section consists of AutoCAD drawings depicting typical landscape details governing the installation of miscellaneous
More informationDodge City s, General Information For Driveway/Sidewalk Permits, Utility Permits.
Dodge City s, General Information For Driveway/Sidewalk Permits, Utility Permits. All private construction and/or maintenance activities which take place within the City right-of-way are subject to oversight
More informationPUBLIC WORKS DEPARTMENT GENERAL NOTES
PUBLIC WORKS DEPARTMENT GENERAL NOTES 1. All construction shall be in strict accordance with the standards of the City of Southlake and governed by the North Central Texas Council of Government's Standard
More information6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.
5 7 8 " NOM. 2" TYPICAL SYSTEM SECTION VERTICAL SUPPORT SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP. CARRIER SPLICE SEE DETAIL B1.4 6" MAX CARRIER OVERHANG, TYP. 1 12 GA HANGER
More informationCITY OF LOS ANGELES Sidewalk Repair Program. Amber Elton, PE
CITY OF LOS ANGELES Sidewalk Repair Program Amber Elton, PE Sidewalk Repair Program Civil Engineer APRIL 20, 2017 Century Plaza Towers 2029 Century Park East City s Goal BEFORE AFTER Improve Mobility in
More informationCONCRETE STEPS, HANDRAILS, AND SAFETY RAIL
SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES
More informationCustom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 22' x 40' - 16' Tall Garage Plan #g22 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical
More informationCHAPTER SEVEN Manual Vehicle & Pedestrian Gates
CHAPTER SEVEN Manual Vehicle & Pedestrian Gates Contents: General Guidelines for Manual Gates Knox Dual Padlock Locking System Manual Gate Signage Pedestrian Gates Purpose: Emergency responders need uniform
More informationSection 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION
Section 7 Roadway GENERAL REQUIREMENTS... 7-1 I. TYPICAL SECTION... 7-1 7.1 LANE WIDTHS... 7-1 7.2 SHOULDER WIDTHS... 7-1 7.3 CROSS SLOPE... 7-2 7.4 CURB AND UNDERDRAINS... 7-2 7.5 SIDEWALKS AND DRIVEWAYS...
More informationGeneral: Exterior walks and paved areas constructed in conjunction with new building projects shall conform to the requirements of these guidelines.
General: Exterior walks and paved areas constructed in conjunction with new building projects shall conform to the requirements of these guidelines. Snow Removal Considerations: The requirement for snow
More informationSUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)
1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12
More informationCustom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 48-14' Tall Garage Plan #g226 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More informationDriveways and Other Concrete Slabs
Driveways and Other Concrete Slabs V I L L A G E O F H A N O V E R P A R K F I R E D E PA R T M E N T I certify that I have received a copy of these regulations and will comply with the regulations contained
More informationSECTION CONCRETE CURBS, GUTTERS AND SIDEWALKS. A. Formwork complete with shoring, bracing and anchorage.
SECTION 02528 CONCRETE CURBS, GUTTERS AND SIDEWALKS PART 1 GENERAL 1.01 WORK INCLUDED A. Formwork complete with shoring, bracing and anchorage. B. Concrete reinforcement complete with required supports,
More informationNOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST
NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INSTALL MANHOLE LIDS FLUSH WITH EXISTING GROUND SURFACE.
More informationSCHEDULE OF QUANTITIES AND PRICES
SCHEDULE OF QUANTITIES AND PRICES BIDDER: SANTA ANA Schedule 33B - City of Santa Ana, 17th Street Crossing BID ITEM DESCRIPTION UNIT QUANTITY UNIT PRICE TOTAL PRICE 33-01570-01 MAINTENANCE AND PROTECTION
More informationProudly Made in the U.S.A.
U.S. Patent No. 7,779,581 Proudly Made in the U.S.A. 24.000 21.600 9 - EQUAL SPACES 1.200 14.400 PART O.A. 36.000 27.429 PART O.A. B B 1.200 VIEW-D 1.250 TOP VIEW 34.286 15 - EQUAL SPACES SIDE VIEW SECTION
More informationPRODUCT EVALUATION Effective Date: June 1, 2013 GDR-40
TEXAS DEPARTMENT OF INSURANCE Engineering Services Program / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective
More informationCOUNTY OF BEXAR. Curbed Streets. Residential PUBLIC WORKS DEPARTMENT
COUNTY OF BEXAR PUBLIC WORKS DEPARTMENT 233 N. Pecos La Trinidad, Suite 420 San Antonio, Texas 78207-3188 Main 210-335-6700 DRIVEWAY APPROACH SPECIFICATIONS Curbed Streets Residential Applicability: All
More informationIvins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards
2.10. LIGHTING DESIGN 2.10.1. IVINS CITY STANDARD STREET LIGHT Ivins City has selected the Spectra TM light fixture system as manufactured by Architectural Areal Lighting (AAL) as a standard for all City
More informationROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING
ADMIN. S 1 1 13 199 POST Anchor Bolts (4 Required) 1 Pole Base Plate Footing PLAN POST Chamfer on Footing ESTIMATED QUANTITIES ITEM UNIT QUANTITY Footing & Eyebolt Class M5 Concrete CU.YD. 0.5 The quantity
More informationSTANDARD DESIGN NOTES 1 / 2
ISIONS STANDARD DESIGN NOTES / 2 N/A ISIONS STANDARD DESIGN NOTES 2 / 2 N/A 2 FENCE AS REQUIRED BY OWNER. SEE DETAIL 8 / DWG. 9 CAP BLOCK LEVEL WEDGE FOR CAP AS REQUIRED FINAL SITE GRADING MATERIAL BY
More informationSPECIFICATIONS FOR TRAFFIC CONTROL SIGNS STREET MARKER BLADES SIGN POSTS MOUNTING BRACKETS AND INSTALLATION AT CUMMINGS RESEARCH PARK
SPECIFICATIONS FOR TRAFFIC CONTROL SIGNS STREET MARKER BLADES SIGN POSTS MOUNTING BRACKETS AND INSTALLATION AT CUMMINGS RESEARCH PARK I. GENERAL A. Cummings Research Park (CRP) Master Plan established
More informationResidential Decks. NOTE: If you are in a development with a 2. Deck Plan (see below)
Residential Decks A permit is required if the proposed deck will be attached to the dwelling and/or is 30 (or more) off the ground. You must obtain a building permit prior to starting any construction
More informationDOCUMENT ADDENDA AND MODIFICATIONS
DOCUMENT ADDENDA AND MODIFICATIONS PART 1 1.1 PROCEDURE GENERAL A. For filing purposes, add Addenda and Modifications to the Contract Documents following this page. Modified June 20, 2017 Addenda and Modifications
More informationCITY OF FARGO SPECIFICATIONS SIGNING
SECTION 4300 SIGNING PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of furnishing all labor, material and accessories necessary
More informationPOST FRAME BUILDING STANDARDS
CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3
More informationCITY OF FARGO SPECIFICATIONS CONCRETE SIDEWALKS AND DRIVEWAYS
CONCRETE SIDEWALKS AND DRIVEWAYS PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of all labor, material, and equipment necessary
More information[Type text] Heber Light & Power. Developers & Excavators. Electrical Service Requirements Manual
[Type text] Heber Light & Power Developers & Excavators Electrical Service Requirements Manual May 2017 E.1.1 - GENERAL REQUIREMENTS PURPOSE This section was prepared to aid developers, contractors, engineers
More informationSECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS
SECTION 14 - RESTORATION OF SURFACES TABLE OF CONTENTS Section Page 14-1 GENERAL... 14.1 14-2 PRIVATE ROADS... 14.1 14-3 STREETS AND PARKING LOTS... 14.1 14-3.01 Aggregate Base... 14.1 14-3.02 Asphalt
More informationPlan Preparation Guide. Chapter 2. Typical Sections - Pavement Design
Plan Preparation Guide Chapter 2 Typical Sections - Pavement Design Section Description Page 1 Typical Sections 2-1 2 Secondary ( C projects) Typical Sections 2-3 3 Base Course 2-4 4 Full Depth Asphalt
More informationSECTION 2200 PAVING CITY OF BLUE SPRINGS, MISSOURI CONSTRUCTION SPECIFICATIONS
SECTION 2200 PAVING CITY OF BLUE SPRINGS, MISSOURI CONSTRUCTION SPECIFICATIONS The City of Blue Springs hereby adopts Section 2200 of the Kansas City Metropolitan Chapter of APWA Construction and Material
More informationMADISON WATER UTILITY MADISON, WISCONSIN UNIT WELL 26 GENERATOR ADDITION AND MCC UPGRADES
AND MCC UPGRADES VICINITY MAP CALL DIGGERS HOTLINE 1-800-242-8511 TOLL FREE LEGEND, ABBREVIATIONS, INDEX GENERAL NOTES AND BENCHMARKS G-1 HIGH POINT ROAD SITE PLAN C-1 PROPOSED SITE PLAN C-2 4" DIA. SCH
More informationGABIONS AND REVET MATTRESSES
GABIONS AND REVET MATTRESSES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Gabions B. Revet Mattresses (Gabion Mattresses) 1.02 DESCRIPTION OF WORK A. Assembly and installation of gabions. B. Assembly and
More informationPORT GAMBLE S'KLALLAM TRIBE IRR ROUTE 40 - RESIDENTIAL ROAD
PORT GAMBLE S'KLALLAM TRIBE IRR ROUTE 40 - RESIDENTIAL ROAD NORTH SECTION 5, TOWNSHIP 27N, RANGE 2E PCAS #P10113R2 VICINITY MAP PROJECT LOCATION SCALE: 1" = 100' DATUM: ELEV. NAVD 88 NORTH: NAD83/1991
More informationSECTION PORTLAND CEMENT CONCRETE
PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the supplemental documents as indicated in the Site Work General Provisions, apply to work of this
More informationONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,
VENT CAP (MUSHROOM TYPE) SOLID CAP EXIST GRADE MIN BUILDING REFER TO NOTE #4 MIN CONCRETE SIDEWALK CURB OR EDGE OF SIDEWALK STREET CLEANOUT (REFER TO NOTE #3) VENT PIPE 4" PVC 6" PVC CLEANOUT CONCRETE
More informationCONCRETE PAVERS. Tel: (Hanover, PA) Color A: Quarry Red Color B: Charcoal Grey Finish: Tudor. Height: 3 1/8 / 80mm Length: 5 7/8 / 138mm
CONCRETE PAVERS MANUFACTURERS & SPECIFICATIONS Pavestone - Plaza Stone Series (6 x6 ) Tel: 770.306.9691 (Tyrone, GA) Color A: Quarry Red Color B: Charcoal Grey Finish: Tudor Sizes - Furniture Zone Sizes
More informationT-WALL Retaining Wall System
CONSTRUCTION MANUAL T-WALL Retaining Wall System The T-WALL Solution... THE NEEL COMPANY 8328 Traford Lane Springfield, VA 22152 Phone 703-913-7858 Fax 703-913-7859 T-WALL Retaining Wall System CONSTRUCTION
More information# 17 ) UN DESERT GREEN FARMS SPECIAL USE PERMIT EXTENSION OF TIME PUBLIC HEARING
# 17 ) UN-101-14 DESERT GREEN FARMS SPECIAL USE PERMIT EXTENSION OF TIME PUBLIC HEARING STAFF REPORT To: Planning Commission Meeting date: December 9, 2015 Item: UN-101-14 Prepared by: Robert Eastman GENERAL
More informationCOMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF DESIGN
GENERAL NOTES DESIGN TABLE NOTES INDEX OF SHEETS 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED. U.S. CUSTOMARY UNITS IN ( ) PARENTHESIS.. ALL "DESIGN" METRIC UNITS INDICATED ARE SOFT CONVERTED
More informationCITY OF DES PLAINES-CONCRETE PROGRAM SIDEWALK, CURB AND DRIVEWAY GUIDELINES
CITY OF DES PLAINES-CONCRETE PROGRAM SIDEWALK, CURB AND DRIVEWAY GUIDELINES SUMMARY AND INTENT OF PROJECT The City of Des Plaines Curb and Sidewalk Program is intended to repair hazardous sidewalk and
More informationA. Testing Laboratory Services: Section B. Excavation, Site Fill and Rough Grading: Section Sub-Base Course Material (If requested).
SECTION 02500 - PART 1 - GENERAL 1.01 RELATED WORK SPECIFIED ELSEWHERE A. Testing Laboratory Services: Section 01411. B. Excavation, Site Fill and Rough Grading: Section 02200. C. Concrete: Section 03310.
More informationSECTION METAL ATHLETIC LOCKERS
SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More informationCITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application
CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application DATE: / / PERMIT # REQUEST FOR: NEW BUILDING ADDITION REMODEL PLUMBING ONLY ELECTRIC ONLY
More informationCITY OF THOUSAND OAKS APPROVAL CHECKLIST FOR REFUSE/RECYCLING ENCLOSURES
CITY OF THOUSAND OAKS APPROVAL CHECKLIST FOR REFUSE/RECYCLING ENCLOSURES ADMINISTRATIVE ITEMS: Waste Management (a.k.a.: G.I. Industries ) must approve plans for a new refuse/recycling enclosure (enclosure)
More informationPRODUCT EVALUATION Effective Date: June 1, 2013 GDR-39
TEXAS DEPARTMENT OF INSURANCE Engineering Services / MC 103-3A 333 Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 322-2212 Fax No. (512) 463-6693 PRODUCT EVALUATION Effective
More informationCounty of Sacramento Standard Construction Specifications January 1, 2008 TECHNICAL PROVISIONS
County of Sacramento Standard Construction Specifications January 1, 2008 TECHNICAL PROVISIONS SECTION 27 CURBS, GUTTERS, SIDEWALKS, AND DRAINAGE STRUCTURES 27-1 GENERAL Concrete curbs, gutters, sidewalks,
More informationNEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1
MTA RR APPARATUS NEW ILLUMINATED LED SIGNAGE LIGHTWEIGHT REMOVABLE ALUMINUM PANEL FENCE 88 NORTH AVE CDR JOB NO. 60 NORTH AVE NORTH AVE CURRENT VIEW OF 88 NORTH AVENUE PROPOSED FACADE AT 88 NORTH AVENUE
More informationSUBDIVISION SECTION STREET DESIGN MANUAL
CITY OF ANAHEIM SUBDIVISION SECTION STREET DESIGN MANUAL A. INTRODUCTION : POLICY STATEMENT B. STREET CLASSIFICATION C. STREET STANDARDS REQUIREMENTS Requirements Approval of Street Improvement Plans Widening
More informationACO Specification Information
ACO INFRASTRUCTURE CurbDrain JULY 2013 Dup to 1,859 psi Standard Curb (150mm) (150mm) 2.23 (57mm) Radius Curb R25 11.80 (300mm) 23.30 (592mm) Centerline 23.56 (598mm) (150mm) 11.80 (300mm) 0.30 (8mm) R25
More information4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)
REQUIRED FOR DETAIL 7 1 8 " 7 8 " SUSPENSION REQUIREMENTS SEE DETAIL B1.2 8" 7 1 1 8 " 4 " 2 1 8 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT
More informationPARKING LOT AND ROADWAY MAINTENANCE
Village of Vernon Hills Community Development Engineering Division Phone 847-367-3704 Fax 847-367-2541 PERMIT APPLICATION PROCESS PARKING LOT AND ROADWAY MAINTENANCE Removal and replacement, concrete and
More informationProudly Made in the U.S.A.
5-Year Warranty Proudly Made in the U.S.A. Cast-In-Place (wet-set) 2 Cast-In-Place (wet-set) Tactile Proudly Made in the U.S.A. In stock colors White 37875 Brick Red 20109 Yellow 33538 Blue 15187 Safety
More information