Reply of POINT NO. 1 :
|
|
- Christal Lang
- 5 years ago
- Views:
Transcription
1
2
3
4 Reply of POINT NO. 1 : Net energy consumption for the plant and the energy balance should be submitted and details regarding Heat recovery system from the exhaust gas and other plant operations should be submitted.
5 PROPANE GAS SAVING DUE TO INGOT PREHEATING 92 Ki data CONSUMPTION AREA EQUIPMENT NAME FUEL TYPE FUEL CONSUMPTION (METER CUBE) CALORIFIC VALUE (KCAL/KG) WASTE HEAT RECOVERY (YES/NO) REMARKS MELTING FURNACE Melting Furnace Total PROPANE YES Waste heat used for preheating the ingots SL NO Total aluminum melting in Tons With pre heating Propane Gas consumption-92ki in m3 Propane gas saved for preheating -92Ki in m TOTAL PROPANE GAS SAVINGS FOR 92KI IS 57603metre cube
6 Fuel Consumption data from Paint 180 K_FUEL CONSUMPTION AREA EQUIPMENT NAME FUEL TYPE FUEL CONSUMPTION (SCM) CALORIFIC VALUE (KCAL/SCM) TOTAL REQUI. MKCAL WASTE HEAT (EXHAUST) MKCAL WASTE HEAT RECOVERY (YES/NO) WASTE HEAT RECOVERY (MKCAL) FUEL CONSERVATION (MKCAL) PAINT SHOP PAINT SHOP TOTAL CNG YES K_POWER CONSUMPTION AREA EQUIPMENT NAME POWER TYPE POWER CONSUMPTION (KWH) POWER CONSERVATION (YES/NO) POWER CONSERVATION (KWH) PAINT SHOP PAINT SHOP TOTAL GRID YES Power Conservation back up sheet Sl No Title of Energy Saving project implemented POWER CONSERVATION (KWH) Status 1 Control Flow of High Pr. Pump through VFD in RO Plant In progress 2 Replace ED Chiller Condenser pump from 25M to 20M Head In progress 3 Overhead light automation Completed 4 Cooling tower eff. improvement by controlling the fan opration on temp. controller Completed 5 Energy wastage reduction in ED chiller system during winter season by using cooling tower Completed 6 Installation of LED Lights in non process area in place of ordinary lights In progress 7 Sludge pit : replace 10 existing pumps from 30M to 15M Head In progress Fuel Conservation back up sheet Sl No Title of Energy Saving project implemented FUEL CONSERVATION (SCM) Status 1 Flue gas heat recovery In progress 2 Magnetic resonator ovens burner Completed 3 Flue gas analysis and control motor adjustment in HWG 3000 In progress
7 Reply of POINT NO. 2- Submission of Details Paint Sludge disposal Paint Sludge Disposal Process - HCIL Paint Sludge generation from Paint shop & POPA Shop Collection of Paint Sludge (hazardous waste in nature) in the containers Drying of paint sludge on the drying beds for the period of 7 to 10 days Storage of the dried paint sludge into HDPE bags Sent to CPCB & RSPCB approved, authorized party for Co-processing
8
9 REPLY Point No. 3 & 4 : VOC Emission data in Plant Location Paint Shop S. No. Parameters Result Permissible limit of Exposure, As per Factories Act, VOC (toluene+ Xylene+ Benzene) mg/m mg/m3 OSHA Test Protocol VOC is with in Govt. specified limit.
10 Location Paint Shop S. No. Parameters Result Permissible limit of Exposure, As per Factories Act, VOC (toluene+ Xylene+ Benzene) 259 mg/m mg/m3 OSHA Test Protocol VOC is with in Govt. specified limit.
11 Location Paint Shop S. No. Parameters Result Permissible limit of Exposure, As per Factories Act, 1948 Test Protocol 1 VOC (toluene+ Xylene+ Benzene) mg/m mg/m3 OSHA VOC is with in Govt. specified limit.
12 Location PO Location POPA S. No. Parameters Result Permissible limit of Exposure, As per Factories Act, VOC (toluene+ Xylene+ Benzene) Test Protoco l NT mg/m3 OSHA S. No. Parameters Result Permissible limit of Exposure, As per Factories Act, VOC (toluene+ Xylene+ Benzene) Test Protoc ol NT mg/m3 OSHA VOC is with in Govt. specified limit.
13 Location POPA S. No. Parameters Result Permissible limit of Exposure, As per Factories Act, VOC (toluene+ Xylene+ Benzene) Test Protocol NT mg/m3 OSHA VOC is with in Govt. specified limit.
14 Stack Air Analysis report VOC in all stack monitoring reports is with in Govt. specified limit.
15 REPLY Point No. 5 TDS Management and Calculation should be submitted for the effluent
16 TDS Balance- Fresh water 1774 KLD & Recycle 558 KLD (Total 2332) Ref EIA 660 cars/ day Bore well 1774 KLD Recycle water 1174 Raw water Tank All units in KLD @ ~ 10% Flushing water 60 Domestic Cooling Process 600 (Drinking, Canteen, Toilets) 60 KLD ~20% (Consumed in drinking) 540@ 700 ~ 12% Blow down (Air washer & 5000 WWTP-614 (Waste water treatment plant (Paint) ~ 90% EVP Loss 92 KL~ 15% Loss 460 Process Car Process Power Train 40 ETP Effluent treatment plant (Coolant) 34@ KL~ 15% Loss Flushing water in toilets STP- 600 Sewage treatment plant Horticulture 90 KL~ 15% Loss KLD Recycle Plant 414 < 2000 PPM TDS in PPM
17 REPLY Point No. 6 Worker Health report S no Reports HONDA STATUS LEGAL REQMNT TECHNICAL REQUIRMENT REMARK 1 MEDICAL EXAMINATIONS OF ASSOCIATES 2 AUDIOMETRY Done (including some areas not under legal reqmnt) Done Yes Manpower selection and details of surveillance methods are subject to local requirement Associates working in High Noise areas Periodical PTA with comparative trend analysis for TTS and PTS Technically relevant to the conditions is important Coordinate with Deptt s & Safety 3 SPIROMETRY Expiratory Flow Metry done (PEFR) 4 X-RAYS Not done Not for auto manufacturing for industry like construction, cement industry, cotton mills, asbestos works etc and cause structural damage in addition to functional disease * 5 MUSCULO SKELETAL DISORDERS Planning a comprehensive Ergonomic program In June 2016, 819 employees were subjected to OHS including 220 Audiometry's Not specified PEFR is internationally recognised as the most effective and appropriate method to detect occupational functional lung disease In industries where fine particles of any material enter the lungs of workers during occupation and cause structural and functional damage PEFR iss good enough for Screening Spirometry is detailed diagnostics not necessary for screening X-ray findings could be critical in trend analysis * In auto industry functional lung disease like asthma and bronchitis etc cannot be detected in Xrays In such cases undue exposure to harmful Xrays is not warranted PEFR (Flowmetry) is useful in Auto industry No Yes Important in terms of Occupational Health Work Environment Monitoring and Task hazrd Analysis reports are must for starting the process
18 Worker Health report
19 Worker Health report
20 REPLY Point No. 7 Water Balance for the plant operation should be submitted
21 Water Balance- Fresh water 1774 KLD & Recycle 558 KLD (Total 2332) Ref EIA 660 cars/ day Bore well 1774 KLD Recycle water 1174 Raw water Tank 558KLD 1732 All units in KLD ~ 10% Flushing water 60 Domestic Cooling Process 600 (Drinking, Canteen, Toilets) 60 KLD ~20% (Consumed in drinking) 540 ~ 12% Blow down 1232 (Air washer & CT) ~ 90% EVP Loss 460 Process Car Process Power Train WWTP-614 (Waste water treatment plant (Paint) 92 KL~ 15% Loss ETP Effluent treatment plant (Coolant) 34 6 KL~ 15% Loss STP- 600 Sewage treatment plant ( ) Recycle Plant 558 Flushing water in toilets Horticulture 448 KLD
22 REPLY Point No. 8 Non-methane HC Ambient Air monitoring data for NMHC Sr. No. Parameters Result Standard Limits 1 Non Methane Hydro Carbon(NMHC) NT 0.01 ppm Non Methane Hydro Carbon(NMHC) is not detected in Ambient Area
23 REPLY Point No. 9 Notification for Industrial area
FORM-1 FOR PROPOSED API PLANT AT MADURAI, TAMIL NADU. Name of Products. Products. 1 Metformin Hydrochloride Paracetamol Bronopol 25
3 ANNEXURES Annexure 1: Production Details Name of Products Products Production Capacity in MT/Month 1 Metformin Hydrochloride 1000 2 Paracetamol 1200 3 Bronopol 25 By-Products Total 2225 1 Acetic acid
More informationENVIRONMENTAL MANAGEMENT PLAN. CONSTRUCTION PHASE 1.Construction Contractors
1. Increased water demand (12 KLD) due water usage for, dust suppression and for workers 2. Sewage generation (11 KLD) and disposal 3. Municipal solid waste generation (15 kg/day) by workers 4. Construction
More informationUNSATURATED POLYESTER RESIN
PROJECT REPORT ON UNSATURATED POLYESTER RESIN BY AQUA CHEM INDUSTRIES Survey No. 50/2, Jodhpar (Nadi), Morbi - 363641, Gujarat. I N D E X Sr. No. Contents Page No. 1 Introduction 3 2 Project Description
More informationTo The Member Secretary State Expert Appraisal Committee Paryavaran Bhavan Sector 10 A Gandhinagar
March 18, 2019 BY HAND DELIVERY/RPAD To The Member Secretary State Expert Appraisal Committee Paryavaran Bhavan Sector 10 A Gandhinagar 382 010 SUB.: APPLICATION FOR SUBMISSION OF ESSENTIAL DETAIL SOUGHT
More informationANNEXURES. 1 Google image showing proposed project site. 3 Manufacturing process details. 4 Details of hazardous waste management
ANNEXURES Annexure No. Description 1 Google image showing proposed project site 2 Plant Lay-Out 3 Manufacturing process details 4 Details of hazardous waste management 5 Details of Effluent Treatment Plant
More informationPre-Assessment Data. Have there been any major changes to equipment or processes in the past year?
CEERI Industrial Assessment Center Boise State University Idaho State University University of Idaho Please return to: Kelly Moylan, Operations Manager kellymoylan@boisestate.edu (208) 426-4053 Form completed
More information7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS
Regn No: Name: (To be written by the candidates) 7 th NATIONAL CERTIFICATION EXAMINATION Nov. 2008 FOR ENERGY MANAGERS & ENERGY AUDITORS PAPER 2: Energy Efficiency in Thermal Utilities Date: 22.11.2008
More informationHALF YEARLY COMPLIANCE REPORT OF ENVIRONMENTAL CLEARANCE CONDITIONS
HALF YEARLY COMPLIANCE REPORT OF ENVIRONMENTAL CLEARANCE CONDITIONS 1. Name of the Project: M/s MCC PTA India Corp. Private Limited Haldia ( WB) Note: Company Name was change from MCC PTA India Corp.Private
More informationPerformance Improvement and Efficiency Optimization of an Industry through Energy Audit
Performance Improvement and Efficiency Optimization of an Industry through Energy Audit Barot Vishal Kumar G, Sirish K Patel Department of Mechanical Engineering, Government Engineering College Valsad,
More informationCentral Chilled Water Plant Sustainable Design. By : George Berbari, CEO DC PRO Engineering
. By : George Berbari, CEO DC PRO Engineering Design Broad Objectives: Most Design Point Energy Efficient. Cost effective. Smallest foot print. Most Energy Efficient based on Year Round Operational. High
More informationTable of Contents. Paint production process Raw material storage details Hazardous waste quantity and proposed details
Table of Contents Annexure No Annexure 1 Annexure 2 Annexure 3A Annexure 3B Annexure 3C Annexure 4 Annexure 5 Annexure 6 Annexure 7A Annexure 7B Annexure 7C Annexure 7D Annexure 8 Annexure 9 Annexure 10A
More informationNATIONAL CERTIFICATION EXAMINATION 2004 FOR ENERGY MANAGERS
NATIONAL CERTIFICATION EXAMINATION 2004 FOR ENERGY MANAGERS PAPER EM2: Energy Efficiency in Thermal Utilities Date: 22.05.2004 Timings: 1400-1700 HRS Duration: 3 HRS Max. Marks: 150 General instructions:
More informationEnvironmental Clearance; Letter No J / 152 / 2006-IA-II (I) Dt and corrigendum dated
Environmental Clearance; Letter No J-11011 / 152 / 2006-IA-II (I) Dt. 21.05.2007 and corrigendum dated 18.09.2007 For Revamping of Ammonia and Urea Plant at Gadepan, Kota; Rajasthan by M/S Chambal Fertilisers
More informationTABLE OF CONTENTS. Para No. Contents Page No
TABLE OF CONTENTS Para No. Contents Page No Chapter-1 Introduction 1.0 Preamble 1 1.1 Location of the project 1 1.2 Objectives of the EIA study 3 1.3 Methodology of study 3 1.4 Structure of EIA report
More informationEnvironmental Clearance; Letter No J / 152 / 2006-IA-II (I) Dt and corrigendum dated
Environmental Clearance; Letter No J-11011 / 152 / 2006-IA-II (I) Dt. 21.05.2007 and corrigendum dated 18.09.2007 For Revamping of Ammonia and Urea Plant at Gadepan, Kota; Rajasthan by M/S Chambal Fertilisers
More informationENVIRONMENT MANAGEMENT PLAN CONSTRUCTION PHASE. suppression instead of water wherever possible. Cell)
ENVIRONMENT MANAGEMENT PLAN No. 1. Increase in water demand due to water usage for, dust suppression and for domestic purpose of workers 2. Sewage generation (9 KLD) and disposal 3. Solid waste generation
More informationCooling tower efficiency U2 Eco-efficiency resources for the food processing industry
Cooling tower efficiency U2 Eco-efficiency resources for the food processing industry Cool savings Many food processors operate cooling towers to meet the cooling needs of the factory. Cooling towers supply
More informationUNILEVER INDIA EXPORTS LIMITED INSTANT TEA FACTORY ETAH ANJAN MAJI FACTORY MANAGER BALAKRISHAN ENGG MANAGER. Confederation of Indian Industry
UNILEVER INDIA EXPORTS LIMITED INSTANT TEA FACTORY ETAH ANJAN MAJI FACTORY MANAGER BALAKRISHAN ENGG MANAGER Brief introduction on Unit Location Year of establishment : 1996 Built in capacity Product Variants
More informationProject : Power & Fuel consumption - an engineering initiative Max Super Specialty Hospital - VAISHALI
Project : Power & Fuel consumption - an engineering initiative Max Super Specialty Hospital - VAISHALI 1 Why we focused on GO GREEN? 2 Why did we choose this project : The only hospital in PAN MAX level
More informationSUSTAINABLE WASTE MANAGEMENT
SUSTAINABLE WASTE MANAGEMENT,Nemam An ISO 9001:2008, ISO 14001:2004, OHSAS 18001:2007 and FSSC 22000:2011 Certified Unit PLANT PROFILE Started with one 600 BPM CSD RGB Line in March 1997. Added one more
More information5. ENVIRONMENT MANAGEMENT PLAN
5. ENVIRONMENT MANAGEMENT PLAN The environmental management plan consist of the set of mitigation measures, management and, monitoring measures to be taken during construction and operation phase to eliminate
More information(Period April 2017 ~ Sept. 2017)
CHAMBAL FERTILIZERS AND CHEMICALS LIMITED, GADEPAN MOEF ENVIRONMENTAL CLEARANCE COMPLIANCE REPORT [PHASE- I] (Period April 2017 ~ Sept. 2017) Letter No.J-11011 / 8 / 87-IA DT.15.11.88 01. The Project Proponent
More informationProject : Power & Fuel consumption - an engineering initiative. VPS Rockland, Dwarka.
Project : Power & Fuel consumption - an engineering initiative VPS Rockland, Dwarka. VPS Rockland Dwarka Well-designed compact 103 bed Multi speciality hospital Plot area of 1250 square meter, and build
More informationIRISH CEMENT PLATIN INVESTING IN OUR FUTURE
IRISH CEMENT PLATIN INVESTING IN OUR FUTURE INTRODUCTION Investing in our future. The next phase of investment in Platin will see further energy efficiency improvements with on site electricity generation
More information4. The ambient air quality monitoring stations We are monitoring the ambient air quality
GLOBAL CALCIUM PRIVATE LTD., 125&126, SIPCOT COMPLEX, HOSUR 635 126 Ref : No. J-11011/411/2006-IA-II(I) dated 1 st August 2007. Compliance Report for the Period ending 31.3.2015 Sl. Specific Conditions
More informationProduct Profile. Quantity in MT/Month CAS Solvent Dark Violet R Solvent Black
Annexure - A Product Profile Sr. No. Product Name Quantity in MT/Month CAS Existing Proposed Ultimate Number End Users 1 Acid Dyes 5.000-5.000 0.000 -- -- Solvent Yellow 82 12227-67-7 Solvent Dark Violet
More informationANNEXURE A DETAILS OF PRODUCTS
Annexures to Form 1 & Pre Feasibility Report Proposed Project for manufacturing of Dyes Intermediates of M/s Jay Dyechem, Narol-Vatva Road,Ta : City, District : Ahmedabad, Gujarat. ANNEXURE A DETAILS OF
More informationJAYPEE NIGRIE SUPER THERMAL POWER PROJECT
JAYPEE NIGRIE SUPER THERMAL POWER PROJECT (A Unit of M/s Jaiprakash Power Ventures Limited) Villages: Nigrie, Tehsil :Sarai District: Singrauli 2014 2015 SUBMITTED M.P. POLLUTION CONTROL BOARD BHOPAL (M.P.)
More informationDistrict Cooling Sustainable Design. Presented by George Berbari CEO of DC PRO Engineering
2016 District Cooling Presented by George Berbari CEO of DC PRO Engineering District Cooling Brief History & Future Central Chilled Water plants existed in the Middle East as early as the 1960 s. Few examples
More informationFor TOR New Projects. Mo. no. : Contact no. and ID of the Applicant
SEAC, Gujarat : Page 1 of 6 For TOR New Projects 1. Basic Information of the Project: i Name & Address of the Project site (Complete details with plot /Survey, Landmark etc. ) M/s. Perstorp Industries
More informationRED CATEGORY CONSENT & AUTHORIZATION ORDER BY REGISTERED POST WITH ACKNOWLEDGEMENT DUE
ANDHRA PRADESH POLLUTION CONTROL BOARD Paryavarana Bhavan, A-III, Industrial Estate, Sanathnagar, Hyderabad-500 018 Phone : 040-23887500, Website : www.appcb.ap.nic.in RED CATEGORY CONSENT & AUTHORIZATION
More informationState Level Environment Impact Assessment Authority Madhya Pradesh Government of India Ministry of Environment & Forests
State Level Environment Impact Assessment Authority Madhya Pradesh Government of India Ministry of Environment & Forests Madhya Pradesh Pollution Control Board E 5. Arera Colony Bhopal 4620 16 visit us
More informationJ-11011/45/2009- IA II (I)
SL SPECIFIC CONDITIONS STATUS 1 Continuous stack monitoring facilities to monitor gaseous emissions from all the stacks shall be provided. The particulate emissions shall be controlled within 50 mg/nm
More informationRamans Enviro Services Pvt. Ltd. Ahmedabad. Annexure A. Product Profile. Crude OBA AND/OR Crude OBA-CBS-X. Standardized OBA Solid AND/OR
Annexure A Product Profile Sr. No. 1 2 Product Crude OBA AND/OR Crude OBA-CBS-X Standardized OBA Solid AND/OR Standardized OBA Liquid Proposed Qty (MT/ M) 400 400 1600 Note : For making Standardized OBA
More informationPART A. M/s Shree Cement Ltd, (Grinding Unit) village - Udepur, Tehsil- Suratgarh, District -Shri Ganganagar, Rajasthan
Page 1 of 9 Environmental Statement for Clinker Grinding Unit of M/s Shree Cement Limited, situated at village - Udepur, Tehsil- Suratgarh, District -Shri Ganganagar, Rajasthan for the Period from: 10
More informationBhushan Steel Limited 1. Name & Address of the owner/occupier of the industry, operation or process
Environment Statement FORM V (See rule 14 of The Environment Protection Act, 1986) Environmental Audit Report for the financial year ending the 31st March 2018. PART A General Information Name of the Company
More informationDESCRIPTIVE REPORT ON STATUS OF COMPLIANCE TO THE CONDITIONS OF ENVIRONMENTAL CLEARANCE AND ENVIRONMENTAL MANAGEMENT
DESCRIPTIVE REPORT ON STATUS OF COMPLIANCE TO THE CONDITIONS OF ENVIRONMENTAL CLEARANCE AND ENVIRONMENTAL MANAGEMENT Subject: Compliance report of Environmental Clearance for CDR & Revamp Reference: J-11011/272/2007-IA,
More informationHigh efficient ESP s has been provided to maintain an emission level below 100mg/Nm 3 in CPP. Modification of ESPs and.
Sl. No. CONDITIONS COMPLIANCE STATUS SPECIFIC CONDITIONS i The gaseous emissions (PM, SO 2, NO X, PAH, HC, VOCs and Fluoride) from various process units shall conform to the standards prescribed by the
More informationPART A. 3. Production Capacity 3.6 Million TPA Cement 4. Year of Establishment th September 2015 PART B WATER AND RAW MATERIAL CONSUMPTION
Page 1 of 8 Environmental Statement for Clinker Grinding Unit of M/s Bihar Cement Plant (A Unit of Shree Cement Ltd.), situated at Jasoia Mor, BIADA, Industrial Growth Centre, Aurangabad, Tehsil & Dist.
More informationCarbon Neutral Manufacturing. Focus Areas. Energy Management Fuel Management Renewable Energy Substitution Supply Chain Management Logistics Travel
6 th November 2015 Company Profile Joint venture Promoted by TATAs & TIDCO. Year of Establishment - 1987 Products - Quartz Analog Wrist Watches, Precious Jewellery, Precision Components & Fashion accessories.
More informationAluminum recycling. Process for recycling beverage cans. Aluminum recycling
Aluminum recycling Aluminum recycling is the process by which scrap aluminum can be reused in products after its initial production. The process involves simply re-melting the metal, which is far less
More informationChambal Fertilisers and Chemicals Limited CFG3 Project Environment Clearance_ Compliance Report (Feb 28, 2018)
Chambal Fertilisers and Chemicals Limited CFG3 Project Environment Clearance_ Compliance Report (Feb 28, 2018) Reference: Environment clearance to CFG3 Project vides MOEF letter.no. J-11011/664/2008-IAII
More informationConceptual plan. Table 1:Area Statement for proposed Corporate Office Complex AREA STATEMENT: -
Conceptual plan Table 1:Area Statement for proposed Corporate Office Complex AREA STATEMENT: - Area of plot= 5293SQM, Sanctioned FAR = 10586SQM as per earlier sanctioned.(2) Sanctioned Built up Area=19480.63
More informationProduct Profile. Annexure A. Annexures to Form - I & PFR. MT/ M Consented Ultimate. Crude OBA AND/ OR Standardized OBA liquid/ powder 190 AND/ OR 2600
Annexure A Product Profile Sr. No. 1 Product Crude OBA AND/ OR Standardized OBA liquid/ powder MT/ M Consented Ultimate 525 190 AND/ OR 2600-23 - Annexure - B Details of Raw Materials Qty (Kg/ Kg) Qty/
More informationJAYPEE NIGRIE SUPER THERMAL POWER PLANT
JAYPEE NIGRIE SUPER THERMAL POWER PLANT (A Division of M/s Jaiprakash Power Ventures Limited) Village: Nigrie, Tehsil: Sarai District: Singrauli 2015 2016 SUBMITTED M.P. POLLUTION CONTROL BOARD BHOPAL
More information(Pollution Control Consultant & Engineers)
(Pollution Control Consultant & Engineers) VISION To improvise and utilize cutting edge technologies and to excel in prevalent technologies for pollution control in India to support development without
More informationEnvironment Management System in Chemical Unit-II (Pyridine & its Derivatives and Speciality Chemicals)
Environment Management System in Chemical Unit-II (Pyridine & its Derivatives and Speciality Chemicals) 1. Air Emission Management: Odour Management There will not be any specific source of air emission
More informationTHE RAMCO CEMENTS LIMITED, KSR NAGAR COMPLIANCE REPORT - ENVIRONMENTAL CLEARANCE CEMENT PLANT 2.5 MILLION TPA CLINKER, 2
THE RAMCO CEMENTS LIMITED, KSR NAGAR COMPLIANCE REPORT - ENVIRONMENTAL CLEARANCE CEMENT PLANT 2.5 MILLION TPA CLINKER, 2.6 MILLION TPA CEMENT & THERMAL POWER PLANT 36 MW EC Lr. No. : J-11011/403/2006-IA-II
More information6 th MONTHLY COMPLIANCE REPORT OF DIBRUGARH-BHOGPARA AREA
6 th MONTHLY COMPLIANCE REPORT OF DIBRUGARH-BHOGPARA AREA As on 01.04.2014 General Condition: Sl No. CONDITIONS COMPLIANCE I. The project authorities must strictly adhere to the stipulations made by the
More informationBRGD Ingot Private Limited 4, D.L. Khan Road, Block-C, Flat No. 201, 2 nd Floor, P.S. Kalighat, P.O. Bhowanipur, Kolkata
SIX MONTHLY COMPLIANCE REPORT (Period: October, 2016 to March, 2017) Refer EC File No. J-11011/258/2012-IA II (I)) dated 27 th August, 2015 Proposed expansion of Steel Melting shop unit (50,400 TPA to
More informationClearance Letter no. : MoEF Vide Letter no. J-11011/79/2003-IA-II (I) dated April 21, 2004
Name of the Project: Jaypee Rewa Plant, Unit of M/s Jaiprakash Associates Limited for expansion Of cement production from 2.5 MTPA to 3.5 MTPA at Jaypee Nagar, District Rewa, Madhya Pradesh Project Code:
More informationAccord Energy Corporation India Pvt. Ltd.
Accord Energy Corporation India Pvt. Ltd. PRE-FEASIBILITY REPORT ON ENVIRONMENTAL ASPECTS OF PROPOSED INCREASE IN CAPACITY 2 x 150 MW to 2 x 180 MW OF EXISTING ENVIRONMENTAL CLEARANCE ( J-13012/107/ 2009-IA-II
More informationBajaj Auto Limited. Waluj. You All
Bajaj Auto Limited (Aurangabad Division) Waluj GC-1000 XCD-125 You All Passenger Platina-125 1 1 Company profile Manufacturing process Water Conservation Target Water Conservation Approach water Conservation
More informationFeasibility Report of Proposed ETP cum STP. M/s. Zakiya Healthcare Plot No.39, Pharmacity Selaqui, Dehradun (Uttarakhand)
Feasibility Report of Proposed ETP cum STP M/s. Zakiya Healthcare Plot No.39, Pharmacity Selaqui, Dehradun (Uttarakhand) 1.0 Introduction M/S Zakiya Healthcare is planning to install an Effluent cum Sewage
More informationANDHRA PRADESH POLLUTION CONTROL BOARD, REGIONAL OFFICE, TIRUPATI
M/s. JANANY CEMENT INDUSTRIES PRIVATE LIMITED SURVEY NO 462, INDUSTRIAL PARK, GUNTAKINDAPALLI VILLAGE, SRIKALAHASTI MANDAL, CHITTOOR DISTRICT, ANDHRA PRADESH EXECUTIVE SUMMARY SUBMITTED BY M/s.Janany Cement
More informationThe Proposed Expansion of Existing ARTEMIS HOSPITAL at Sector-51, Gurgaon (Haryana). In CONCEPTUAL PLAN PROJECT LAYOUT AND DEVELOPMENT CONTEXT
CONCEPTUAL PLAN PROJECT LAYOUT AND DEVELOPMENT CONTEXT ABOUT PROJECT The Proposed Expansion of Existing ARTEMIS HOSPITAL at Sector-51, Gurgaon (Haryana). In earlier project planning the total plot area
More informationEnergy Efficiency Opportunity Analysis Consolidated Precision Products. Anshul Gupta Advisor: Mick Jost
Energy Efficiency Opportunity Analysis Consolidated Precision Products Anshul Gupta Advisor: Mick Jost Company Overview Consolidated Precision Products is an aerospace foundry. Produces high precision
More informationWASTE WATER RECYCLE MANAGEMENT ION EXCHANGE INDIA LTD
WASTE WATER RECYCLE MANAGEMENT ION EXCHANGE INDIA LTD Blue Issues Scarcity & rising costs Drought Pollution Tremendous pressure on available finite water resources due to Rapid industrialisation, Expanding
More informationNational Award for Excellence in Water Management 2008
Established : 1999 BOSCH - JAIPUR anagement Land Area 2007 conducted : 202,350 by CII Sohrabji m 2 Godrej Green Business Centre, Hyderabad. COMPANY PROFILE Built Area : 30,834 m 2 Employees : 1,383 Turnover
More informationRajasthan State Pollution Control Board
M/s Raj West Power Private Limited Village- Bhadresh, Tehsil:Barmer District:Barmer Sub: Ref: Sir, Consent to Operate under section 25/26 of the Water (Prevention & Control of Pollution) Act, 1974 and
More informationOPTIMISATION OF WATER USAGES IN THERMAL POWER PLANTS AND A STUDY ON DRY COOLING SYSTEM
CONFERENCE ON WATER OPTIMISATION IN THERMAL POWER PLANTS OPTIMISATION OF WATER USAGES IN THERMAL POWER PLANTS AND A STUDY ON DRY COOLING SYSTEM S. K. Thakur, Dr. L. D. Papney, Chief Engineer (I/C), TE&TD
More informationSix Monthly Compliance Status Report
Six Monthly Compliance Status Report Annexure -1 Name of Project : Expansion of Multi-Purpose Fluorinated Specialty ( Organic) Chemicals Plant at Village- Jhiwana, Tehsil- Tijara, District- Alwar ( Rajasthan)
More information(E.C. Letter No. F.No.J-11011/316/2006-IA II (I) Dated 21-11-2007 and EC extension letter dated 01-03-2013) (For the Period 1 st April 15 to 30 th Sept. 15) FOR Dahej Petrochemical Complex M/s. ONGC Petro
More informationShilpa Sathi COMMON APPLICATION FORM FOR SETTING UP AN INDUSTRY IN WEST BENGAL
COMMON APPLICATION FORM FOR SETTING UP AN INDUSTRY IN WEST BENGAL 1. of the Applicant: SWS IDENTIFICATION NUMBER General Information [Please see Instructions before filling up the Application] Residential
More informationProposed Project of Halcyon Labs Pvt Ltd D-2/CH : 335,336,337, GIDC-Dahej-2, DIst: Bharuch, Gujarat Ramans Enviro Services Pvt Ltd Ahmedabad
1. EXECUTIVE SUMMARY OF THE PROJECT BRIEF SUMMARY OF THE PROJECT : TYPE OF PROJECT : Proposed Project for manufacturing of pharma intermediates by Halcyon Labs Pvt.Ltd. LOCATION : Proposed Project of Halcyon
More informationBhushan Steel Limited 1. Name & Address of the owner/occupier of the industry, operation or process
Environment Audit Statement FORM V (See rule 14 of The Environment Protection Act, 1986) Environmental Audit Report for the financial year ending the 31st March 2017. PART A General Information Name of
More information6.1 Introduction to Wastewater Issues
Section 6: Water Pollution This Section will help you: Understand if you generate industrial wastewater; Understand where your wastewater goes; Make sure you meet requirements for floor drains; Properly
More informationPRE-FEASIBILITY REPORT
PRE-FEASIBILITY REPORT For ToR of Proposed Project of MANUFACTURING OF SYNTHETIC ORGANICCHEMICALS (RESINS) (5 f B IND II) By M/s M R INDUSTRIES SURVEY NO. 58/1 & 58/3 OPPOSITE WHOLESOME FOOD PVT. LTD.,
More informationSEIAA-AGENDA
112th SEIAA Meeting Agenda SEIAA Meeting number: 112 Meeting Date July 27, Discussion Item: 01 Open Exhibition Centre and Parkland at Sector 5&8, PCNTDA, Pune : The Development Plan of Pimpri- Chinchwad
More informationGold Standard Passport CONTENTS
CONTENTS A. Project title B. Project description C. Proof of project eligibility D. Unique Project Identification E. Outcome stakeholder consultation process F. Outcome sustainability assessment G. Sustainability
More informationKirloskar Ferrous Industries Limited, Bevinahalli Village, Koppal Taluk & Dist Karnataka
0 FORM V (See rule 14) ENVIRONMENTAL STATEMENT FOR THE FINANCIAL YEAR ENDING THE 31 ST MARCH-2017 PART A i. Name and address of the owner: Mr. R. V. Gumaste Occupier of the industry Managing Director Operation
More informationManagement of battery waste
Management of battery waste Production of lead from secondary sourcesexceeds its primary production. As per an estimate, consumption of lead in the country is about 4.5 lakh tons out of which, only about
More informationCHECK LIST OF DOCUMENTS / OTHER REQUISITES FOR OBTAINING VARIOUS CLEARANCES FROM THE STATE POLLUTION CONTROL BOARD, ODISHA.
CHECK LIST OF DOCUMENTS / OTHER REQUISITES FOR OBTAINING VARIOUS CLEARANCES FROM THE STATE POLLUTION CONTROL BOARD, ODISHA. A. CONSENT TO ESTABLISH UNDER THE PROVISIONS OF WATER (PREVENTION & CONTROL OF
More informationPoint wise reply. There is no change in water requirement and wastewater generation. However, water balance enclosed as Annexure-I.
Mohammadpur Korji, P.S.- Phulwarisharif, District- Patna, Bihar by M/s Balprada Built Pvt. Ltd. Point wise reply Point 1: Submit revised water balance for the Project There is no change in water and wastewater
More informationSr. No. Date of starting the project and completion schedule. January 2012 January 2017 (Tentative)
Six Monthly Progress Report reg. Construction of Group Housing Colony at village Sarai Aurangabad in Sector 3-A, Bahadurgarh (Distt. Jhajjar), Haryana by M/s Prabhu Shanti Real Estate Pvt. Ltd., due in
More informationWater Management. How do we reduce and recycle our wastewater?
How do we reduce and recycle our wastewater? SRM IST has a long-term commitment for conservation for water. The Institute of Science and Technology will regularly monitor the use of water with frequent
More informationNorbert De Souza Avinash Wagh Prasanna Kulkarni. CII National Award for Excellence in water Management th Dec 17 th Dec 2008 CII-Hyderabad
MAHINDRA & MAHINDRA LTD AUTOMOTIVE SECTOR- PLANT I NASHIK Norbert De Souza Avinash Wagh Prasanna Kulkarni CII National Award for Excellence in water Management 2008 16 th Dec 17 th Dec 2008 CII-Hyderabad
More informationRisk Management Measures
Risk Management Measures Legal Entity: Site: ISD Kokszoló Kft ISD Kokszoló Kft Substance: (coal), coke-oven / 65996-78-3 Registration number: 01-2119519215-46-0039 Date: 15 December 2012 Information on
More informationHINAUTI LIMESTONE MINE Mine Lease area ha. (A UNIT OF JAIPRAKASH ASSOCIATES LIMITED) JAYPEE VIHAR, SIDHI (M.P)
HINAUTI LIMESTONE MINE Mine Lease area 378.261 ha. (A UNIT OF JAIPRAKASH ASSOCIATES LIMITED) JAYPEE VIHAR, SIDHI (M.P) 2012-2013 SUBMITTED TO M.P.POLLUTION CONTROL BOARD BHOPAL (M.P.) Jaypee Sidhi Cement
More informationTHE RAMCO CEMENTS LIMITED, KSR NAGAR COMPLIANCE REPORT - ENVIRONMENTAL CLEARANCE CEMENT PLANT 2.5 MILLION TPA CLINKER, 2
THE RAMCO CEMENTS LIMITED, KSR NAGAR COMPLIANCE REPORT - ENVIRONMENTAL CLEARANCE CEMENT PLANT 2.5 MILLION TPA CLINKER, 2.6 MILLION TPA CEMENT & THERMAL POWER PLANT 36 MW EC Lr. No. : J-11011/403/2006-IA-II
More informationCII NATIONAL AWARD FOR EXCELLENCE IN ENERGY MANAGEMENT 2018 TCS-SAHYADRI PARK, PUNE
CII NATIONAL AWARD FOR EXCELLENCE IN ENERGY MANAGEMENT 2018 TCS-SAHYADRI PARK, PUNE Ajay Deshmukh Sr Manager Tech Admin Rajendra Takavale Asst Manager - ESHS # Brief introduction on Company/Unit Tata Consultancy
More informationBRIEF SUMMARY OF THE PROJECT
BRIEF SUMMARY OF THE PROJECT Office Complex at Plot No. 5A & 5B, Shopping Mall, Vasant Kunj Phase - II, New Delhi Developed by M/s Oil and Natural Gas Corporation Limited BRIEF DESCRIPTION OF THE PROJECT
More informationAnnexure-I List of Products
Annexure-I List of Products Sr. No. Name of Products Quantity (MT/Month) 1. Mono Chloro Acetic Acid (MCA) 300 2. Chloro Acetyl Chloride (CAC) 150 3. Tri Chloro Acetyl Chloride (TCAC) 150 4. Aluminum Chloroide
More informationTECHNOLOGY. E-COMPANY Holding, s.e., Europe
TECHNOLOGY E-COMPANY Holding, s.e., Europe With ZERO-EMISSION WASTE TREATMENT RECYCLING is guaranteed and total ENVIRONMENT is safeguarded COMBUSTIBLE is green and free BAT - Best Available Techniques
More informationEFFICIENT BUILDINGS BEYOND DESIGN... Rumi Engineer.. Godrej Green Building Consultancy Services
EFFICIENT BUILDINGS BEYOND DESIGN... Rumi Engineer.. Godrej Green Building Consultancy Services GLOBAL SCENARIO 1 Billion new consumers in emerging market cities by 2025 Nearly 80 Cities are expected to
More informationEnergy Reduction Programs: Understanding, Implementing & Delivering. PL Energy Services
Energy Reduction Programs: Understanding, Implementing & Delivering PL Energy Services PL Energy Services Value to Condominium Directors Control Maintenance Fees Maximize Rebates Measurement & Verification
More informationSCHEDULE - I. D. No. :.; Date:. Explanatory note for filling in application form for Consent/ Authorization
vameku rék fudks ckj iz' kklu ANDAMAN & NICOBAR ADMINISTRATION iznw"k.k fu;a=.k lfef r POLLUTION CONTROL COMMITTEE DEPARTMENT OF SCIENCE AND TECHNOLOGY Dolly Gunj, Port Blair Ph. No.250370 Tel. Fax 250370
More information14 th NATIONAL CERTIFICATION EXAMINATION FOR ENERGY AUDITORS August, 2013
14 th NATIONAL CERTIFICATION EXAMINATION FOR ENERGY AUDITORS August, 2013 PAPER 4: Energy Performance Assessment for Equipment and Utility Systems Date: 25.8.2013 Timings: 14:00-16:00 Hrs Duration: 2 Hrs
More informationDR. SANJAY V. PATIL HEAD AND TECHNICAL ADVISER DEPARTMENT OF ALCOHOL TECHNOLOGY VASANTDADA SUGAR INSTITUTE, MANJARI, PUNE (INDIA)
DR. SANJAY V. PATIL HEAD AND TECHNICAL ADVISER DEPARTMENT OF ALCOHOL TECHNOLOGY VASANTDADA SUGAR INSTITUTE, MANJARI, PUNE (INDIA) Email: sv.patil@vsisugar.org.in AIDA Technical Seminar www.vsisugar.com
More informationANNEXURE. Annexure 1: Production Details. Annexure 2: Site Location Map. Annexure 3: Site Layout Map & Area breakup for Terminal
ANNEXURE Annexure 1: Production Details Annexure 2: Site Location Map Annexure 3: Site Layout Map & Area breakup for Terminal Annexure 4: Operation Philosophy Annexure 5: Copy of Consent to Operate Annexure
More informationPresentation on Excellence in Energy Management-2017
Presentation on Excellence in Energy Management-2017 Company Profile Kuantum Papers is in the business of production and marketing of writing & printing paper, while conserving precious resources & protecting
More informationCoke Manufacturing. Environmental Guidelines for. Multilateral Investment Guarantee Agency. Industry Description and Practices. Waste Characteristics
Multilateral Investment Guarantee Agency Environmental Guidelines for Coke Manufacturing Industry Description and Practices Coke and coke by-products (including coke oven gas) are produced by the pyrolysis
More informationPRODUCTION EFFICIENCY/ POLLUTION PREVENTION FACTORY ASSESSMENTS FOR FABRIC MILLS AND DYE HOUSES IN BANGLADESH
গ ণ প রজ ত ন ত র ব ল দ শ PEOPLE S REPUBLIC OF BANGLADESH PRODUCTION EFFICIENCY/ POLLUTION PREVENTION FACTORY ASSESSMENTS FOR FABRIC MILLS AND DYE HOUSES IN BANGLADESH Dhaka, 8 May 2011 Summary 1. The approach
More informationEnergy Efficiency: Best Practices Thermal Power Stations
Energy Efficiency: Best Practices Thermal Power Stations By Ravindra Datar Senergy Consultants (P) Ltd Cell: +91 9821271630 ravi@senergy.co.in www.senergy.india.com Key Parameters Inlet (as well as Re-heater)
More informationDESCRIPTIVE REPORT ON STATUS OF COMPLIANCE TO THE CONDITIONS OF ENVIRONMENTAL CLEARANCE AND ENVIRONMENTAL MANAGEMENT
DESCRIPTIVE REPORT ON STATUS OF COMPLIANCE TO THE CONDITIONS OF ENVIRONMENTAL CLEARANCE AND ENVIRONMENTAL MANAGEMENT Subject: Compliance report of Environmental Clearance for Plant 3 Reference: J-11011/603/2010-IA,
More informationEnvironment protection initiatives at Watson Pharma- Ambernath. AMMOR December 2014
Environment protection initiatives at Watson Pharma- Ambernath 19.03.2016 AMMOR December 2014 By Nitin Ambavane INDEX 1. Effluent treatment plant success story 2. Online monitoring system 3. Environment
More informationM/s. LAKSHMANAN CEMENTS PVT LTD, Survey Number 69-3, 69-4, Pachanapalli Village, Chittoor Mandal and District, Andhra Pradesh
M/s. LAKSHMANAN CEMENTS PVT LTD, Survey Number 69-3, 69-4, Pachanapalli Village, Chittoor Mandal and District, Andhra Pradesh EXECUTIVE SUMMARY SUBMITTED BY M/s. Lakshmanan Cements Pvt Ltd No. 58-A, 25
More informationBRIEF DESCRIPTION OF THE PROJECT
BRIEF DESCRIPTION OF THE PROJECT. Introduction M/s Indorama Industries Limited is proposing to expand their project known as Indorama Spandex for manufacture of manmade textile fibre using petro chemical
More informationORGANIC RANKINE CYCLE TECHNOLOGY PRODUCTS AND APPLICATIONS APRIL 2013 EAR 99 - NLR
ORGANIC RANKINE CYCLE TECHNOLOGY PRODUCTS AND APPLICATIONS APRIL 2013 UNITED TECHNOLOGIES CORP. Hamilton Sundstrand Pratt & Whitney Sikorsky Otis UTC Fire & Security UTC Power Carrier 2 TURBODEN OVERVIEW
More informationA NEW PRODUCT FOR EXHAUST AIR PURIFICATION
A NEW PRODUCT FOR EXHAUST AIR PURIFICATION Frédéric MILCENT, engineer, Research and Development Division, GAZ DE FRANCE Philippe BOUGIT, engineer, Research and Development Division, GAZ DE FRANCE 1. INTRODUCTION