Everyone can be an Expert. Electrochemical Detector. Autosampler. Complete HPLC-ECD
|
|
- Brooke White
- 6 years ago
- Views:
Transcription
1 Everyone can be an Expert Electrochemical Detector Autosampler Complete HPLC-ECD
2 Eicom ECD-700 Eicom ECD-700 Electrochemical Detector for HPLC Eicom's electrochemical detector, the ECD-700, offers superior stability and sensitivity that reviles that of mass spectrometry detectors, but without the cost and special expertise. Electrochemical detectors easily detect a wide range of easily oxidized or reduced compounds, and you can rely of Eicom's extensive experience to help you find the best set-up for your research goals. Depending of the requirements of a particular method, the ECD-700 can be configured with up to two detector cells. Both amperometric and coulometric types are available. Features High Sensitivity, 30 fg sensitivity for Dopamine at S/N ratio=3. Easy system setup and ready-to-use applications. Instant access to the working electrode of the amperometric detector cell. Expandable design for more demanding users or protocols. ECD-700 Configurations Standard One amperometric detector cell with single graphite working electrode. Optional Configurations Coulometric Cell Standard Option 1 Option 2 Option 3 1 st Detector Cell A da A /da A /da/c 2 nd Detector Cell A C A: Amperometric detector, da: Dual amperometric working electrodes that share a common reference electrode and can be installed in parallel or series with the flow. C: Coulometric flow cell. Amperometric Cell Amperometry vs. Coulometry In amperometry the analyte contacts the surface of a solid working electrode. Amperometry achieves better signal-to-noise ratios resulting in better sensitivity. Coulometry depends on porous working electrode to promote the complete electrolysis of the analyte as it passes. At Eicom, we find the best approach is to employ coulometric cells to prepare the analyte for detection with an amperometric cell. Working Electrode Designs or Amperometry Dual Amperometry Coulometry
3 Eicom ECD-700 Simplicity + Expandability The keyword during the development of the ECD-700 was expandability. Over the past 25 years of Eicom ECD products, our goal has been to help users kick start new projects with our ready-to-use applications and reliable instruments. And now for more demanding applications, we have introduced the ECD-700, which has two detector cell capacity and allows for many combinations of detector types and working electrodes. Heart of Sensitivity, Amperometric Detector Cell Eicom's advanced working electrode design requires much less maintenance than many ECD users may have become accustomed to. When the need does arise, the electrode can easily be accessed to replace it or wipe off any chemical build-up. Even after the cell is opened, the initial baseline signal is quickly restored without worry. Diagram of Detector Cell Working Electrode EICOM WE-XX Gasket GS-XX The pressure inside the cell is maintained by a spring-loaded ball assembly that ensures a constant pressure. The ball compresses the working electrode assembly at one point to evenly distribute the pressure across the working electrode. Variety of Working Electrodes Materials Graphite Electrode WE-3G, very stable and best S/N ratio. Little maintenance is required. Included in the standard configuration. Pure Graphite WE-PG, stable even at higher applied voltage Glassy Carbon WE-GC, conventional working electrode Platinum WE-PT, good for hydrogen peroxide. Commonly used with inline enzyme reactor columns. Gold WE-AU, well suited for thiol group detection Silver WE-AG Dual working electrode for use with Eicom's amperometric detector cell. Graphite WED-3G Glassy Carbon WED-GC Coulometric detector cell working electrode material. Porous Carbon (refer to Option 3 on previous page)
4 Eicom ECD-700 Columns Many Ready-to-use applications Eicom provides complete, step-by-step protocols for a variety of applications. These protocols include instructions for sample collection and preparation, mobile phase recipes, storage and preparation of standards, and exact instrument settings. If you want to modify a method or create your own method, we can advise you on where to start and give you feedback about the data along the way. Typical EC detectable compounds Phenols Anilines Estrogens Opiates Catechols Quinones Hydroxycoumarins Phenothiazines Indoles Tocopherols Purines Thiols Pulse Damper Electrochemical detection is extremely sensitive to changes in pressure. Consequently, each stroke of an HPLC pump can cause oscillations in the baseline signal, which necessitates the use of a pulse damper to obtain the lowest detection limit. If you will not be using an Eicom pump, we recommend using a pulse damper, such as Eicom PL-500. A Pulse damper is not required for Eicom pumps. Specifications of ECD-700 Standard Configuration Detection Method Working Electrode Applied Potential Range Auto Zero Function Reference Electrode Counter Electrode Cell Volume Inlet Tubing OD Input Output Auto Zero Input Log File Amperometric, DC with 3 electrode potentiostat Standard single graphite. Optional dual working electrode with a shared reference electrode. -2,000 mv ~ +2,000 mv in increments of 1mV -1,000 na ~ +1,000 na, resets in less than 0.7 sec. Each detector cell zeros separately. When dual electrode is installed, the signal from both applied voltages zero together. Ag / AgCl Stainless Steel 316 Active area = 1 µl. Outlet has 100 µl reservoir 1/16 inch Contact closure signal, DC 0 V ~ 5 V, ON 1 mv OFF 10 µa Delay of 0 sec, 3 sec and 6 sec after 1sec signal input Accept DC 0 V ~ 5 V, ON 1 mv OFF 10 µa User can save a log of reference and working electrode replacements for each channel through keypad Specification and design of products may change without notice. US Office 7313 Carroll Road Suite F, San Diego, CA Phone Eicom Europe 1A Dartmouth Terrace Ranelagh Dublin 6, Ireland Phone Headquarters 113 Kitaenmendencho Shimotoba Fushimiku Kyoto-Shi Kyoto-Fu Japan Phone
5 Eicom Complete 700 Series Eicom 700 Series Complete HPLC-Electrochemical Detector System If you need the very best performance of Eicom ECD-700, we recommend using the three 700 Series components as one system. The 700 Series includes an HPLC Pump (EP-700), Temperature Controller (ATC-700) and Electrochemical Detector (ECD-700). When used together, we promise the best results. Sensitivity comes from more than just the detector. To achieve optimal performance from electrochemical detectors, there are important considerations. The Eicom 700 Series Total System addresses all of these requirements to ensure the best sensitivity. A chemically inert or, at a minimum, passivated interior because metal ions increase the background signal A means to stabilize the baseline because oscillations in the pressure caused by the HPLC pump produce concomitant oscillations in the signal baseline Effective temperature control because electrochemical detection is very sensitive to temperature Eicom EP-700 HPLC Pump No more pulse dampers required! Revolutionary pump design can effectively quench flow pulses. Built-in, computer control continually adjusts the piston velocity during each stroke to minimize Complete HPLC-ECD fluctuations in the pressure. Pulse free pumping works in both gradient and isocratic modes. Because the EP-700 does not require a damper, the volume between a column and the HPLC pump is minimal. This means rapid acquisition of steady-state pressure after starting the pump and more immediate solvent effects that are important to accurate gradients. An innovative 300 µl volume degasser is built in to guarantee continuous pumping and preventing noise at the detector. Signal Baselines Pulse-free Mode OFF Pulse-free Mode ON Standard Configuration EP-700M --- one micro flow pump (10 to 500 µl /min ) Options EP-700H --- one high flow type pump EP-700MM --- two micro flow pumps with gradient controller EP-700HH --- two high flow pumps with gradient controller EP-700MH --- one micro flow and one high flow pump
6 Eicom Complete 700 Series Eicom ATC-700 Temperature Controller The Eicom ATC-700 uses a Peltier element that both heats and cools by convection to maintain precise temperature control. The system responds to just a 0.05 C change and controls the temperature of the both the columns and ECD cells. Specifications of EP-700 and ATC-700 Pump Unit (EP-700) Type Dual reciprocating piston pump Internal Volume 300 µl/channel Construction Chemically inert materials at all liquid contacting surfaces Maximum Flow Rate 3 ml/min Flow Rate Ranges Liquid Contacting Surfaces Pressure Limit Gradient Mode Micro flow type: 100 to 500 µl/min with 1 µl/min increments, 4 µl/stroke High flow type: 0.5 to 3.00 ml/min with 0.01 ml/min increments, 32 µl/stroke PEEK, Sapphire, Ruby, PTFE, PCTFE 20 MPa High pressure linear gradient, 10 steps. Available when 2 same pump installed. Casing (EP-700) Dimension Weight Power Supply Temperature Controller (ATC-700) Temperature Regulation Setting Range 400 (w) x 400 (d) x 190 (h) mm approx. 13 kg with one pump, approx. 16 kg with two pumps AC V, 50/60 Hz, 200 W Peltier device for heating and cooling by convection 15 to 55 C, 1 C increament External Signal Input: Gradeint Start/Stop, Gradient Initialization Output: Pump Pressure Recommended Range Column Capacity 20 to 45 C at 25 C ambient 25 cm x 2 HPLC columns Degasser Unit (EP-700) Degassing Chamber Volume 300 µl x 2 channels Dimension Weight 400 (w) x 400 (d) x 145 (h) mm approx. 10 kg Lines 2 Channels Power Supply AC V, 50/60 Hz, 210 VA Eicom AS-700 INSIGHT Autosampler We know your time is limited. Eicom's reliable autosampler injects samples while you are away. Autosamplers are must have item for knowledgeable HPLC users. For more details, please see the INSIGHT Autosampler brochure. INSIGHT Specification and design of products may change without notice. US Office 7313 Carroll Road Suite F, San Diego, CA Phone Eicom Europe 1A Dartmouth Terrace Ranelagh Dublin 6, Ireland Phone Headquarters 113 Kitaenmendencho Shimotoba Fushimiku Kyoto-Shi Kyoto-Fu Japan Phone
IC-D3160 Ion Chromatograph
IC-D3160 Ion Chromatograph IC-D3160 ion chromatograph is a new modular design of the high stability of ion chromatograph, combining Analytical Technologies Limited independent research and development
More informationExcellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology
Excellence in gas analyzers since 1957 Over 186 years of Jobin Yvon optical experience The expertise of HORIBA combustion technology EMGA Series E MGA S ERIES O XYGEN/NITROGEN & HYDROGEN A NALYZERS A World
More informationFor Safe and Delicious Water
RESIDUAL CHLORINE ANALYZER 400G NON-REAGENT FREE CHLORINE ANALYZER FC400G 400G RESIDUAL CHLORINE ANALYZER FC400G NON-REAGENT FREE CHLORINE ANALYZER Bulletin 12F01A01-01E www.yokogawa.com/an/ For Safe and
More informationC196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph
C196-E067A Prominence UFLCXR Shimadzu Ultra Fast Liquid Chromatograph New Prominence UFLC Series Line-up Prominence UFLCXR In Pursuit of Higher Separation and Sensitivity The Prominence UFLCXR is an ultra-high-speed
More informationDionex Eluent Generator Cartridges
User Manual Dionex Eluent Generator Cartridges 065018 Revision 06 February 2018 For Research Use Only. Not for use in diagnostic procedures. Product Manual for Dionex Eluent Generator Cartridges (Dionex
More informationControlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.
Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software Technical Overview Abstract The Waters Empower 2 chromatography data software with ICS 1.05
More informationeasy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.
easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success. Introducing the Agilent 1120 Compact LC Simply a better value. Is your lab looking for better, more reproducible results
More informationTutorial Corrosion II. Electrochemical characterization with EC-Lab techniques
Tutorial Corrosion II Electrochemical characterization with EC-Lab techniques 1 OUTLINE 1. Introduction 2. Types of corrosion a) Uniform corrosion b) Localized corrosion 3. Corrosion experiment 4. EC-Lab
More informationPreparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions
Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions Gary Scharrer and Joan Stevens, Ph.D. Gilson, Inc Middleton, WI www.gilson.com Abstract Purification of synthetic,
More informationMethod Translation in Liquid Chromatography
Method Translation in Liquid Chromatography Technical Overview Abstract Ronald E. Majors Agilent Technologies, Inc. 2850 Centerville Rd Wilmington, DE 19808 USA With the recent emphasis on high performance
More informationFlexibility with. Preparative HPLC
Flexibility with Preparative HPLC Date: August 26 th, 2014 Time: 09.00 10.00 am CEST 1 Who are your Presenters? Dr. Christian Textor Product Manager Preparative HPLC Dipl. Biol. Hagen Schlicke Product
More information// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.
Configuration: XPLORER with ARCHIE and GLS* // XPLORER-NS Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. TE Instruments has developed the XPLORER-NS, a Total Nitrogen and
More informationPreparative HPLC System
High Performance Liquid Chromatograph Preparative System Preparative HPLC System C90-E84 From Preparative LC to Purification and Powderization Purification Enters the Next Era Shimadzu provides a wide
More informationDetermination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography
Application Note 206 Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography Introduction The Bayer Process is used to isolate alumina (Al 2 O ) from bauxite. In this process,
More informationElectrochemical Detection
Thermo Scientific Electrochemical Detection User s Compendium P/N: April 2013 Part of Thermo Fisher Scientific User s Compendium for Electrochemical Detection (ED) Thermo Scientific User s Compendium for
More informationGlyphosate and AMPA in drinking water
Glyphosate and AMPA in drinking water Markus Läubli, Bastian Brand, Andrea Aeschlimann, and Gabriele Zierfels In March 2015, the International Agency for Research on Cancer (IARC) published a report which
More informationExploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma
Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma Yun Wang Alelyunas, Mark D. Wrona, Jim Murphy, Angela Doneanu, Gregory
More informationFast Preparative Column Liquid Chromatography (PCLC)
Fast Preparative Column Liquid Chromatography (PCLC) Application Note 224 Joan Stevens, Ph.D. and Gary Scharrer Introduction Preparative HPLC is recognized as a prime method for obtaining pure compounds
More informationSurface Plasmon Resonance Systems
Innovative precision instruments for over a century Surface Plasmon Resonance Systems Label-free Molecular Interaction Analysis ReichertSPR Answers: Is there an interaction? How fast? How strong? How long?
More informationTemperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!
JC Series High Performance Controllers...at the lowest prices anywhere! Structure Units available in standard DIN sizes (1/16, 1/8, and 1/4 DIN) NEMA 4X protective construction Black enclosure Programmable
More informationAn Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions
An Automated System for At-Line cess Analysis of Biopharmaceutical Fermentation Reactions Frank Steiner, Susanne Fabel, Fraser McLeod, Dionex Corporation, Germering, Germany Abstract Monitoring amino acid
More informationOn-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes
On-Line SPE CARTRIDGES for Rapid Cleanup and Extraction of Analytes User s Guide What is the strata-x on-line SPE cartridge? The strata-x on-line cartridge combines the revolutionary benefits of the patent
More informationMicrofluidic Systems for Cell Growth and Cell Migration Studies
Microfluidic Systems for Cell Growth and Cell Migration Studies Maria Dimaki 1, Pranjul Shah 1, Dorota Kwasny 1, Jacob Moresco 2 and Winnie E. Svendsen 1 1 DTU Nanotech Department of Micro- and Nanotechnology,
More informationSCION GC Series. The Gas Chromatographers Choice for Separations
SCION GC Series The Gas Chromatographers Choice for Separations Innovation in Gas Chromatography Scion Instrument s tradition of innovation and product reliability have combined to create the next generation
More informationAgilent InfinityLab Preparative Flow Cells for MWD & DAD
Agilent InfinityLab Preparative Flow Cells for MWD & DAD Technical Note This technical note describes the preparative flow cells for the Agilent 1260 Infinity II DAD WR (G7115A) and Agilent 1260 Infinity
More information64C Amplification Block. Instruction Manual
64C Amplification Block Instruction Manual Caution: All rights reserved. Quidel Corporation reserves the right to modify this manual at any time without notice. Any part of the manual shall not be duplicated,
More informationQualification of High-Performance Liquid Chromatography Systems
Qualification of High-Performance Liquid Chromatography Systems L. Huber Hewlett- Packard GmbH, Waldbronn December 1998 Manuscript of an article published in BioPharm, Vol 11 Number 11, November 1998,
More informationPreparative, Pilot & Process Columns
Preparative, Pilot & Process Columns 321 Preparative, Pilot & Process Columns Contents Prep Columns... 322-323 Dynamic Axial Compression Columns (DAC)... 324-325 Pilot Columns... 326-327 Chromatography
More informationAPPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC
UOP 63-13: Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC Fast Analysis in
More informationAgilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205
Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205 WARNING: The Agilent MetaCarb Ca PLUS calcium column is packed with a polymeric material that requires special care. Introduction
More informationThe Effect of Working Electrode Gasket Thickness on the Sensitivity and Linearity of Carbohydrate Response by Pulsed Amperometric Detection
TECHNICAL NOTE 186 The Effect of Working Electrode Gasket Thickness on the Sensitivity and Linearity of Carbohydrate Response by Pulsed Amperometric Detection Authors Beibei Huang and Jeffrey Rohrer Thermo
More informationGas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator
Gas Generator ULTRA HIGH PURE - HIGH FLOW Gas Generator Zero Air Generator for GC Zero Air Generator produces a continuous flow of high purity Zero Air at selected pressure. The modular pressure swing
More informationPRODUCT MANUAL FOR THE. ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N
PRODUCT MANUAL FOR THE EGC II K 2 CO 3 CARTRIDGE EGC II K 2 CO 3 CARTRIDGE, P/N 058904 ELECTROLYTIC ph MODIFIER (EPM) EPM, P/N 063175 EGC CARBONATE MIXER EGC CARBONATE MIXER, 2-mm, P/N 063443 EGC CARBONATE
More informationGas Chromatograph. GC-8A Series C184-E016B
Gas Chromatograph GC-8A Series C184-E016B GC-8A Series Dedicated Single Detector Gas Chromatograph GC that meets increasing analytical requirements GC that can analyze instantaneously GC that is tough
More informationTechnical Note. Introduction
Online HPLC for Biotechnology: Groton Biosystems Automated Reactor Sampling System and Agilent 1200 Series LC System Technical Note Introduction Online analytical instrumentation facilitates productive,
More informationUFL Micro Biogas CHPs
UFL Micro Biogas CHPs The UFL Micro Biogas CHPs are based on the highly durable Petter industrial diesel engine. Low cost replacement parts are available worldwide. This range of micro biogas CHPs has
More informationElectricide CDE Electrochemical Chlorine Dioxide Generators
Electricide CDE Electrochemical Chlorine Dioxide Generators electricide ClO2 WHAT IS ELECTROCHEMICAL GENERATION? Chlorine dioxide is traditionally generated using purely chemical reactions of 2 chemicals
More informationConfident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions
Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions Screening and Confirmation Chemical Analysis Solution Unit November, 2009 Page 1 Agilent s New 6540 Ultra High
More informationMonosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD
Monosaccharide and Sialic Acid Determinations in Biosimilars Using HPAE-PAD A large number of innovator biotherapeutics are currently losing patent protection, resulting in an increased interest to develop
More informationProminence Preparative HPLC System
High Performance Liquid Chromatograph Preparative System Prominence Preparative HPLC System C190-E110B Prominence Preparative System [Product Concept] The most important aspects of separation and purification
More informationCoreless Vacuum Induction Furnace
1/8 High tech furnaces for high tech alloys and processes www.otto-junker.de Coreless Vacuum Induction Furnace Coreless Vacuum Induction Furnace Blaise Pascal 1623-1662 The vacuum treatment of molten steel
More informationFast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover
columns ProSwift Reversed-Phase Monolith Columns for Protein Analysis ProSwift reversed-phase columns use a unique monolith technology for fast, high-resolution HPLC and LC/MS separations of proteins.
More informationUnderstanding Extrusion
Chris Rauwendaal Understanding Extrusion 2nd Edition Sample Chapter 2: Instrumentation and Control ISBNs 978-1-56990-453-4 1-56990-453-7 HANSER Hanser Publishers, Munich Hanser Publications, Cincinnati
More informationChem 321 Lecture 23 - Liquid Chromatography 11/19/13
Chem 321 Lecture 23 - Liquid Chromatography 11/19/13 Student Learning Objectives High Performance Liquid Chromatography With the advent of relatively inexpensive and reliable pumps, the development of
More informationEvaluation of efficiency and collector time constant of a solar flat plate collector
Evaluation of efficiency and collector time constant of a solar flat plate collector Abhijit Devaraj 1, Abhishek Hiremath 2, Akshay R Patil 3, Krushik B N 4 Department of Mechanical Engineering, BMS College
More informationGAS 3050P NDIR FLUE GAS
Portable gas analyser GAS 3050P NDIR FLUE GAS Industrial flue gas analysis Powerful, robust and transportable on any industrial site, the GAS 3050P NDIR FLUE GAS analyser offers the same performances as
More informationApplication of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study
Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study Application note Biotherapeutics and Biologics Authors Suresh Babu C.V., Anne
More informationBONDING OF MULTIPLE WAFERS FOR HIGH THROUGHPUT LED PRODUCTION. S. Sood and A. Wong
10.1149/1.2982882 The Electrochemical Society BONDING OF MULTIPLE WAFERS FOR HIGH THROUGHPUT LED PRODUCTION S. Sood and A. Wong Wafer Bonder Division, SUSS MicroTec Inc., 228 SUSS Drive, Waterbury Center,
More informationCorrosion Rate Measurement on C-Steel
Measurements of corrosion rate on Carbon-steel using Electrochemical (potentiodynamic Polarization, EIS etc.) technique. Corrosion Rate Measurement on C-Steel Abdullah Al Ashraf 1. Introduction: The degradation
More informationAgilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES
Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES THE AGILENT 7820A GC SYSTEM FORWARD-THINKING INNOVATION, EVERYDAY RELIABILITY AND VALUE Is your lab looking for better, more reproducible results
More information1080 Total Organic Carbon Analyzer
1080 Total Organic Carbon Analyzer Easily Analyze Difficult to Oxidize Samples Total organic carbon (TOC) measurement is a well-established technique that provides valuable information about water quality
More informationC146-E096 TD-20. Shimadzu Thermal Desorption System
C146-E096 TD-20 Shimadzu Thermal Desorption System Thermal Desorption Thermal desorption systems trap target substances carried in mobile phase by adsorption in a sample tube packed with adsorbent. Then,
More informationPioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS
Pioneering ALD experience since 1974 The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS SUNALE P-SERIES ALD SYSTEMS PRODUCT CATALOGUE Description SUNALE P-series ALD system SUNALE P-series
More informationKOBRA CELL Art. No. K01
R-Biopharm Rhône Ltd KOBRA CELL Art. No. K01 Instruction Manual R-Biopharm for the safety of your analysis. R-Biopharm Rhone Ltd 2 Contents 1. Introduction to the KOBRA CELL... 4 1.1 Intended Use... 4
More informationED40 ELECTROCHEMICAL DETECTOR OPERATOR S MANUAL Dionex Corporation
ED40 ELECTROCHEMICAL DETECTOR OPERATOR S MANUAL 1995 Dionex Corporation Document No. 034855 Revision 03 March 1995 1995 by Dionex Corporation All rights reserved worldwide Printed in the United States
More informationGas Chromatography Assignment Chem 543/443
Gas Chromatography Assignment Chem 543/443 1. Introduction Capillary gas chromatography (GC) is one of the most popular analytical techniques used in today s research. Its popularity is mainly due to efficient
More informationCompact flue gas analyser: testo 300 M-I
220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial
More informationChambers and Instrumentation CHAMBERS. STORA: 22 m 3 chamber
Chambers and Instrumentation CHAMBERS STORA: 22 m 3 chamber The chamber is made of electropolished stainless steel with inner dimensions 3.2 x 2.9 x 2.4 meters (breadth x length x height). The volume of
More informationFlexCell TM. Electrochemical flow cell. User manual A, Edition 9, 2017
FlexCell TM Electrochemical flow cell User manual 102.0010A, Edition 9, 2017 T +31 71 5813333 F +31 71 5813334 info@ AntecScientific.com www.antecscientific.com Antec is an ISO 9001:2008 certified company.
More informationELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE
ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE Introduction The ability of materials to conduct electric charge gives us the means to invent an amazing array of electrical and electronic devices,
More informationFraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System
Application Note Biologics & Biosimilars Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction Chromatography Agilent 126 Infinity II Bio-Inert System 7 6 5 4 5. 7.5
More informationIsco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation
Isco EZ TOC Continuous on-line TOC/TC measurement using low-temperature oxidation Easy Programming High Efficiency UV Reactor Enhanced NDIR Detector Flexible Four-Motor Pump System Advanced Dual Calibration
More informationUsing the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides
Application Note 25390206 Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides Keywords Model 5380 Organophosphorus Pesticide PFPD PFPDView Phosphorus
More informationApplication Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany
Quantification of trace-level herbicides in drinking water by online enrichment with the Agilent Infinity Series Online-SPE Solution and Triple Quadrupole MS Detection Application Note Environmental Author
More informationHigh performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES
TECHNICAL NOTE 43334 High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES Keywords Free-running, Plasma, RF generator, Solid-state Using inductively
More informationMass Transport Effects on Electroreduction of Carbon Dioxide
Mass Transport Effects on Electroreduction of Carbon Dioxide Tiek Aun Tan 1, Sara Yasina binti Yusuf 1 and Umi Fazara Muhd Ali 1 1 Universiti Malaysia Perlis Abstract: The electrochemical reduction of
More informationModule-13. Corrosion and Degradation of materials
Module-13 Corrosion and Degradation of materials Contents 1) Corrosion of metals 2) Corrosion of ceramics 3) Degradation of polymers Deterioration of materials Conventional engineering materials are not
More informationFeaturing Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System
Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 15EX LC/MS System compact, rugged, The API 15EX LC/MS System is the most rugged and reliable single quadrupole
More informationInjection moulded low cost bipolar plates for PEM Fuel Cells
Injection moulded low cost bipolar plates for PEM Fuel Cells A. Heinzel 1,2, F. Mahlendorf 2 *, O. Niemzig 2, C. Kreuz 1 1 Zentrum für BrennstoffzellenTechnik (ZBT) GmbH, Carl-Benz-Straße 21, 4758 Duisburg,
More informationIN SITU MONITORING OF REINFORCEMENT CORROSION BY MEANS OF ELECTROCHEMICAL METHODS
ABSTRACT IN SITU MONITORING OF REINFORCEMENT CORROSION BY MEANS OF ELECTROCHEMICAL METHODS Oskar Klinghoffer, M.Sc. FORCE Institute, Park Allé 345, DK-2605 Brøndby, Denmark The well-known and usually adapted
More informationDevelopment of Novel NOx Sensors and System Integration with Alumina Heater Elements
Development of Novel NOx Sensors and System Integration with Alumina Heater Elements UC Riverside PEMS 2016 International Conference & Workshop March 17, 2016 F. Bell, M. Boettcher, J. Chee, J. Fitzpatrick,
More informationERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)
ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014) WATER COOLING TOWER School of Bioprocess Engineering University Malaysia Perlis EXPERIMENT Water Cooling Tower 1.0 OBJECTIVES 1.1 To determine energy and
More informationAccelerated Stress Tests in PEM Fuel Cells: What can we learn from it?
Accelerated Stress Tests in PEM Fuel Cells: What can we learn from it? D.P. Wilkinson 1,3, W. Merida 2,3 1 st Workshop : Durability and Degradation Issues in PEM Electrolysis Cells and its Components Fraunhofer
More informationElectricity. Characteristic and efficiency of PEM fuel cell and PEM electrolyser Stationary currents. What you need:
Stationary currents Electricity Characteristic and efficiency of PEM fuel cell and PEM electrolyser What you can learn about Electrolysis Electrode polarisation Decomposition voltage Galvanic elements
More informationChloride/Sulfate Analyzer
Chloride/Sulfate Analyzer 3000CS Analyzer Trace sensitivity Low maintenance Grab sample capability Fully automatic calibration Automated Chloride/Sulfate Measurement Sensitive and Reliable Chloride/Sulfate
More informationHeat Value Gas Chromatograph ISO standard version
No. SS2-HGC303-0100 OVERVIEW Heat Value Gas Chromatograph ISO standard version The model HGC303 is the world smallest gas chromatograph, which is capable of analyzing 11 different components of natural
More informationElectrolysis, electrode polarisation, decomposition voltage, galvanic elements, Faraday s law.
Characteristics and efficiency of PEM fuel cell TEP Related Topics Electrolysis, electrode polarisation, decomposition voltage, galvanic elements, Faraday s law. Principle In a PEM electrolyser, the electrolyte
More informationOn-line, Real Time Measurement Of Extracellular Brain Glucose Using Microdialysis And Electrochemical Detection
On-line, Real Time Measurement Of Extracellular Brain Glucose Using Microdialysis And Electrochemical Detection P.G. Osborne* BAS, Inc. Department of Research and Development,Oshiage 36-4-1, Sumida-ku,
More informationElectron Capture Detector for GC-2010 Plus
Electron Capture Detector for GC-2010 Plus C180-E080 The World's Highest Level of Durability and Performance for a Capillary ECD Electron Capture Detector Novel Contact Free Technology was incorporated
More informationHYDROGEN AS A CARRIER GAS. Gas Chromatography new frontiers: can Hydrogen substitute Helium?
HYDROGEN AS A CARRIER GAS Gas Chromatography new frontiers: can Hydrogen substitute Helium? Manufacturing UHP gas generators for lab analysis since 1979, CLAIND is seating in Lenno, on Como Lake, where
More informationSize Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column
Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column Application Note Bio-Pharmaceutical Authors M. Sundaram Palaniswamy and Andrew Coffey Agilent Technologies,
More informationProtein Quantitation using various Modes of High Performance Liquid Chromatography
Platzhalter für Bild, Bild auf Titelfolie hinter das Logo einsetzen Protein Quantitation using various Modes of High Performance Liquid Chromatography Grotefend, S.; Wroblewitz, S.; Kaminski, L.; Limberger,
More informationPerkinElmer Supplies/Parts. GC Accessories. Autosampler Syringes
Autosampler Syringes Volume, Code, Gauge, Length, Point Style QTY OEM No. PerkinElmer No. Part No. Hamilton Syringes 5μL, ASN, 23s, 70mm, #3 1 88035 N6101390 24-88035 5μL, ASN, 26s, 70mm, #3 1 88040 N6101380
More informationThis User Bulletin does not apply to PROCISE clc instruments.
User Bulletin PROCISE Protein Sequencing System (491/492/494) 1 July 1997 (updated 06/2001) SUBJECT: PROCISE Feature Upgrade Kit Summary This User Bulletin describes the hardware, firmware, and software
More informationMS Certified Vials. Pre-cleaned and certified vials for mass spectrometry
Pre-cleaned and certified vials for mass spectrometry The FIRST and ONLY pre-cleaned, low particle, low background chromatography vial When your instrumentation, sample handling and methodology is pushing
More informationMETHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES. NOTE: Performance of this method should not be
1285 METHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES NOTE: Performance of this method should not be attempted by persons unfamiliar with the operation of a flame ionization
More informationThermal Performance of Thermoelectric Cooler (TEC) Integrated Heat Sink and Optimizing Structure for Low Acoustic Noise / Power Consumption
Thermal Performance of Thermoelectric Cooler () Integrated Heat Sink and Optimizing Structure for Low Acoustic Noise / Power Consumption Masami Ikeda, Toshiaki Nakamura, Yuichi Kimura, Hajime Noda The
More informationPassive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015
Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325 Nicola Watson July 2015 EPA 325 - Refinery perimeter monitoring Revised Federal regulation (CFR 40, part 60 and 63) to be implemented
More informationHeart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System
Heart-cut 2D-LC/M approach for pharmaceutical impurity identification using an Agilent 640 Q-TF LC/M ystem Application ote Pharmaceuticals Author iji Joseph Agilent Technologies, Inc. Bangalore, India
More informationMAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer
MAX300-RTG Industrial Process Mass Spectrometer PRODUCT NOTE Real-Time Gas Analysis Process Automation and Control Product Quality Analysis www.extrel.com Introducing the MAX300-RTG Optimize Your Manufacturing
More informationCharacteristic and efficiency of PEM fuel cell and PEM electrolyser
Related topics Electrolysis, electrode polarisation, decomposition voltage, galvanic elements, Faraday s law. Principle and task In a PEM electrolyser, the electrolyte consists of a protonconducting membrane
More informationCharacterization methods for bipolar plate materials Identifying low cost solutions for industrial use
Zentrum für BrennstoffzellenTechnik GmbH Characterization methods for bipolar plate materials Identifying low cost solutions for industrial use A common cooperation between the academic world for the industrial
More informationACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE
ACQUITY UPLC I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE COMPLEX CHALLENGES SOLVED Looking for answers to the most complex scientific challenges is what you do. Your research could lead to ground-breaking
More informationS700 Modular Gas Analyzer. Measures more than 60 different gases
Product information S7 Modular Gas Analyzer Measures more than 6 different gases Modular +++ Superior Quality +++ Universal C US Typical Applications Chemical and petrochemical process gas analysis Ammonia
More informationMassPREP On-Line Desalting Cartridge
CONTENTS I. INTRODUCTION II. INSTALLING THE MASSPREP ON-LINE DESALTING CARTRIDGE INTO THE SENTRY.1 X 1 MM GUARD COLUMN HOLDER III. RECOMMENDED LC/MS SYSTEM CONFIGURATION TO MINIMIZE MS SOURCE CONTAMINATION
More informationApplication Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider
Combining small-scale purification and analysis of monoclonal antibodies on one instrument Protein purification with high-volume injection using the Agilent 126 Infinity Bio-inert Quaternary LC System
More informationDiaphragm Liquid Pumps
Diaphragm Liquid Pumps MODELS 52 F F 12 FP 21 52 F F 12 FP 21 FEATURES Self priming Dry running Oil-less, non lubricated Suitable for continuous operation Chemical resistent pump materials for aggressive
More informationLiquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use
Liquid Chromatograph Liquid Chromatograph Mass Spectrometer CL Series for In Vitro Diagnostic Use Consistency. Performance. Reliability. Shimadzu s CL Series LC, LC-MS, and LC-MS/MS for in vitro diagnostic
More informationElectronic Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 2013
Sodium-ion battery based on ion exchange membranes as electrolyte and separator Chengying Cao, Weiwei Liu, Lei Tan, Xiaozhen Liao and Lei Li* School of Chemical and Chemistry Engineering, Shanghai Jiaotong
More informationGeneral Specification
General Specifications TB600G Laser Turbidity Meter GS 127A1 General With the recent development in membrane filtration technologies, organic filters have come into practical use as a highperformance treatment