WASTEWATER PUMPING STATION INVENTORY
|
|
- Cory Clark
- 6 years ago
- Views:
Transcription
1 Page 1 WASTEWATER PUMPING STATION INVENTORY Civic Address: Year Constructed: Pump Station Type (circle): Building (Y/N): SUBMERSIBLE DRYWELL SELF-PRIMING Holding Tank (Y/N): Valve Chamber (Y/N): Connected to Scada System (Yes/No): Design Capacity (L/s): Legend: INA = Information not Available/Accessible N/A = Not Applicable : OI = Operator Input, RD = Record Drawing, DD = Design Drawing, OD = Other Drawing, FV = Field Verified, IN = Inferred Pump Apparatus PUMPS Application: Make: Model: Serial #: Rated Power (kw or HP): Impeller Impeller Diameter (mm): Speed (RPM): Suction Diameter (mm): Capacity (duty, L/s): TDH (duty, m): Discharge Diameter (mm): Seal PUMP MOTORS Make: Model #: Efficiency (%): Serial Number: Horsepower: Rated Power (kw or HP): Full Load (amps): Service Rating: Enclosure Speed (RPM): Drivetype:
2 Page 2 Forcemain Date Installed: Diameter (mm): Material: Year of Last Break or Failure: Frequency of Breaks: Length (m): Structure Volume Max Water Level (m3): Rails and Chains (Y/N): Ventilation Level Monitoring: Wetwell Dimensions (mm): Top Elevation (m): Invert Elevation (m): Incoming Pipe Invert (m): Overflow Elevation (m): Overflow Overflow Environment: Structure Volume (m3): Ventilatation Drywell Dimensions (mm): Top Elevation (m): Invert Elevation (m): Sump Pump (Y/N): Structure Volume (m3): Dimensions (mm): Holding Tank Ventilation Disinfection of Overflow (Y/N): Level Monitoring: Overflow Metering (Y/N): Material: Mechanical Piping Diameter (mm):
3 Page 3 Valves VALVES Diameter (mm): VALVE CHAMBER Structure Drainage to Wetwell (Y/N): Ventilation Dimensions (mm) Instrumentation FLOW METERS Size (mm) LEVEL MONITORING (type): TEMPERATURE MONITORING (type): GAS MONITORING (type, type of gas): PRESSURE MONITORING (type): CHEMICAL DOSING SYSTEM (type): ODOUR CONTROL SYSTEM (type):
4 Page 4 RACKS/SCREENS Operation: Mechanical GRINDER 1 2 MIXER SAFETY HATCH 1 2 Manufacturer: Power (kw): Safety Grating (Y/N): Material: Electrical Main Service Panel (V): Main Service Panel (A): Phase (One/Three): Boxes and Conduits: Yard Lighting Interior Lighting NSP Meter Number: Transfer Switch (Y/N): Transfer Switch Rating (kw) Environment Power Factor Correction Installed (Y/N): kvar Rating: Control Panel Type of Environment: Manufacturer: Hour Meters (Y/N): Starter Control NEMA Rating: Emergency Power Make: Model: Serial Number: Size/Power (kw): Emergency Containment (Y/N): Fuel Tank Capacity (L): Fuel Storage Fuel Storage Material: Quick Connect (Y/N):
5 Page 5 Civil/Building CIVIL BUILDING Driveway Area (m2): Driveway Retaining Walls (Y/N): Fencing (Y/N): Drainage Structures (Y/N): Proximity to Watercourse (m): Susceptibility to Flooding (Y/N): Structure Dimensions: Roof Material: Heating Hoists/Davits (Y/N): Ventilation Security System (Y/N):
6 Page 6 Photo Log Description Taken (Y/N): File Name(s) Pump Nameplates Pumps Wetwell Electrical Panel Nameplate Piping Valving Hatches Elevation Views (N,S,E,W) Motor Nameplate
TOP Pre-engineered Fiberglass Pump Station
TOP Pre-engineered Fiberglass Pump Station The Optimum Pump Station Flygt pump station controls Xylem offers offers a fully engineered control panel solution. Our integrated, purposely designed control
More informationHPGR200 2 HP. Capacity-U.S. G.P.M.
Performance RPM: 3450 Discharge: 1-1/4" Solids: 2" Wholesale Products Page: 6710-1 Section: Performance 100 80 2 HP TOTAL HEAD IN FEET 60 40 20 0 0 10 20 30 40 50 Capacity-U.S. G.P.M. 60 The curves reflect
More informationDesign Specifications & Requirements Manual
4 SEWAGE PUMPING STATIONS 4.1 DEFINITION AND PURPOSE... 1 4.2 PERMITTED USES... 1 4.3 DESIGN CRITERIA... 1 4.3.1 General... 1 4.3.2 Site Layout and Servicing... 2 4.3.3 Structural... 3 4.3.4 Flow Capacity...
More informationSHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001
Performance RPM: 1550 Discharge: 1-1/2" Solids: 3/4" Wholesale Products Page: 6680-1 Section: Performance Dated: April 2002 Supersedes: January 2001 The curves reflect maximum performance characteristics
More informationSK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.
Performance RPM: 1750 Discharge: 2" Solids: 2" Wholesale Products Page: 6270-1 Section: Performance 12 40 9 30 HEAD-METERS 6 3 TOTAL HEAD IN FEET 20 10 SK60 0 0 Capacity-U.S. G.P.M. 20 40 60 80 100 120
More informationVSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING
Flows to 200 GPM. TDH to 95 Feet at 1750 RPM Free Standing or Guide Rail Design. Available in Standard Submersible or Explosion Proof Design. Provided with 25 feet of submersible motor power cable. Cast
More informationHUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:
Performance RPM: 1550 Discharge: 1" Solids: 1/8" Wholesale Products Page: 6660-1 Section: Performance The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower.
More informationSPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007
Performance SPX50 RPM: 1750 Discharge: 2" Solids: 2" SPX50H RPM: 1750 Discharge: 1 1 2" Solids: 3 4" Wholesale Products Page: 6800-1 Section: Performance The curves reflect maximum performance characteristics
More informationSECTION PACKAGE BOOSTER PUMP STATIONS
SECTION 331223 PACKAGE BOOSTER PUMP STATIONS Scope: The Contractor shall install a pump station at two locations to be determined by the Owner. These pump stations shall be designed to deliver flow to
More informationPumping Plant Detailed Evaluation Worksheet
Sheet 1 of 5 Observer Date Checked by Date Field name or number Acres irrigated Hardware Inventory: Power plant: Electric motor(s): Main pump Booster (if used) Make Model Rated rpm Rated hp Internal combustion
More informationDIVISION VI INDIVIDUAL GRINDER PUMP INSTALLATIONS
DIVISION VI INDIVIDUAL GRINDER PUMP INSTALLATIONS VI-1.000 DESCRIPTION 1.010 General A. Any extension of the Kitsap County sanitary sewer extension shall be completed in accordance with the applicable
More informationSession 2 Pump Selection. Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017
Session 2 Pump Selection Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017 Quick Refresh System Curves graphically show the relationship between flow rates and associated total dynamic
More informationEnergy Management Workshop
Energy Management Workshop Variable Frequency Drives for Water Systems August 24, 2016 Presenters Amanda Keyes, Tighe & Bond Mark Mizia, Eaton Corporation Michael Toto, Tighe & Bond Example VFD Application
More informationSUBMERSIBLE SEWAGE EJECTOR
PERFORMANCE DATA Wholesale Products Page: 6270-1 RPM: 1750 Discharge: 2 Solids: 2 12 40 HEAD-METERS 9 6 3 TOTAL HEAD IN FEET 30 20 10 SK60 0 0 Capacity-U.S. G.P.M. 0 20 40 60 80 100 120 Liters/Second 0
More informationHYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.
PERFORMANCE DATA Wholesale Products Page: 6280-1 RPM: 1650 Discharge: 2 Solids: 2 12 40 9 30 HEAD-METERS 6 HEAD-FEET 20 3 10 0 0 Capacity - U.S. G.P.M. 0 30 60 90 120 150 180 Liters/Second 0 2 4 6 8 10
More informationSD/SW/VS50 SD50 SW50 VS50
Performance RPM: 1550 Discharge: 1-1/2" Solids: 3/4" Wholesale Products Page: 7130-1 Section: Performance SD50 SW50 VS50 The curves reflect maximum performance characteristics without exceeding full load
More informationHYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR
PERFORMANCE DATA Wholesale Products Page: 7140-1 Dated: August 2002 Supersedes: May 2002 RPM: 1550 Discharge: 2 Solids: 2 8 25 7 20 5 4/10 HP HEAD-METERS 4 HEAD-FEET 15 3 10 2 0 0 20 40 60 80 Capacity-U.S.
More informationHYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT
PERFORMANCE DATA Wholesale Products Page: 6570-1 RPM: 1550 Discharge: 1 ½ Solids: ½ V-A1 W-A1 D-A1 Head, meters 8 4 Head, feet 30 20 10.3 HP 0 0 Capacity, US GPM 0 10 20 30 40 50 60 liters/second 0.0 1.0
More informationG2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011
100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the
More informationSump Pumps Office procedures for the Drainage & Grading section
County of Los Angeles Department of Public Works Building and Safety Division Grading and Drainage Section Sump Pumps Office procedures for the Drainage & Grading section Introduction This manual provides
More informationHCP Product Introduction
HCP Product Introduction CHAPTERS 1.HCP PUMP 2.Description of products 3.Relevant information of technology 1.HCP PUMP Company Introduction Establish time:1979 Annual sales volume: US$20,000,000 Increased
More informationG2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011
100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the
More informationVSS S U B M E R S I B L E S E W A G E P U M P S
7 2 9 8 / 2 3 HP % % 64% 7 5 HP HP 5 HP % % C u r v e P a g e V S S - 4 5 R P M M O D E L : V S S - 4 E I M P E L L E R : V S A - 4 C - 2-5 A l s o a p p l i e s t o V S S - 5 E & V S S - 6 E 7 7 65 55
More informationdp pumps The dynamics of water sewage & wastewater pumps 50 & 60 Hz
dp pumps The dynamics of water sewage & wastewater pumps 50 & 60 Hz index Control of wastewater 03 Model identification 05 DVV-M 07 DVV-H 08 DVK-M 09 DRK-V 10 DRV-S 11 DRV-V 12 DRK-S/D 13 DRV-V4 14 DRK-K
More informationModule 9 : Sewage And Storm water Pumping Stations. Lecture 11 : Sewage And Storm water Pumping Stations
1 P age Module 9 : Sewage And Storm water Pumping Stations Lecture 11 : Sewage And Storm water Pumping Stations 2 P age 9.1 Introduction There are certain locations where it is possible to convey sewage
More informationCity of Wentzville. Standard Specifications and Construction Details Amendment List
Amendment No. 1 Standard Specifications and Construction Details Amendment List Date: September 21, 2009 Subject: SCD 700.23 - Residential Entrance Layout and drawing revised to more clearly show the location
More informationAPPENDIX G DESIGN FLOW CALCULATIONS
APPENDX G DESGN FLOW CALCULATONS Page 0 0 Township of Huron East Egmondville SPS Alternatives Job # : 0656 Design Briel and Not - ROUTE #2 Date: July 27,200 Revised : July 27, 200.0 Background The Township
More informationCity of Gardiner, Maine Wastewater Committee Meeting. CSO Storage Tank & Screening Evaluation
City of Gardiner, Maine Wastewater Committee Meeting CSO Storage Tank & Screening Evaluation December 11, 2013 Introduction - Update on field work - Flow monitoring - Survey - GIS - Borings - Assessment
More informationSeries Sump and Sewage Systems
Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column
More informationPUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...
PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series
More informationPUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...
PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Vertical
More informationComplete Grinder Package Offering
Complete Grinder Package Offering NEW TL-Pro System Package includes your choice of a 2HP submersible grinder pump, TL-Pro or TG-Pro lift out system, control panel, three floats and a fiberglass basin
More informationBIDDING SCHEDULE SEWER LIFT STATION NO. 2 REPLACEMENT PROJECT CITY OF ALHAMBRA City s Project No. N2M17-83
Item No. BIDDING SCHEDULE SEWER LIFT STATION NO. 2 REPLACEMENT PROJECT CITY OF ALHAMBRA City s Project No. N2M17-83 DESCRIPTION EST. QTY. UNIT UNIT PRICE TOTAL PRICE GENERAL BID ITEMS 1 Per Plans and Specifications
More informationSERIES 800 Quality Design Features Assure Long, Trouble-Free Service
Heavy Duty Sump Pumps SERIES Quality Design Features Assure Long, Trouble-Free Service WIDE RANGE OF APPLICATIONS: Industrial Process Pollution Control Sump Drainage Flood Control Hazardous, Toxic & Inflammable
More informationSTAINLESS STEEL SUBMERSIBLE PUMPS
STAINLESS STEEL SUBMERSIBLE PUMPS FOR CHEMICALLY AGGRESSIVE LIQUIDS Ranges CH, CTP, CMX, CV, CVX, CK Discharge - DN 1 HIGHER PERFORMANCE TO MEET EVERY CHALLENGE PROVEN TECHNOLOGY FOR EXTENDED APPLICATIONS
More informationPDF / 75 HP SUBMERSIBLE PUMP DOCUMENT
18 April, 2018 PDF / 75 HP SUBMERSIBLE PUMP DOCUMENT Document Filetype: PDF 466.7 KB 0 PDF / 75 HP SUBMERSIBLE PUMP DOCUMENT We are leading power backup provider company in India, We manufacture and supply
More informationSK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.
Performance SK75/100 RPM: 1750 Discharge: 2" Solids: 2" Wholesale Products Page: 6300-1 Section: Performance 12 40 9 30 HEAD-METERS 6 3 TOTAL HEAD IN FEET 20 10 SK75 SK100 0 0 Capacity-U.S. G.P.M. 20 40
More informationMUNICIPAL WASTEWATER PUMP STATION DESIGN PROBLEMS AND SOLUTIONS Jeff Chapin, P.E. Dewberry 8401 Arlington Boulevard Fairfax, VA 22032
MUNICIPAL WASTEWATER PUMP STATION DESIGN PROBLEMS AND SOLUTIONS Jeff Chapin, P.E. Dewberry 8401 Arlington Boulevard Fairfax, VA 22032 ABSTRACT The growth of the Northern Virginia Area around Washington
More informationSubmersible. Issue 2 / De-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application.
Issue / Submersible Pumps De-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application. Email: enquiries@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland:
More informationSPECIFYING PUMPS WHY DO PUMPS FAIL.
SPECIFYING PUMPS WHY DO PUMPS FAIL 1 www.sspma.org SSPMA Sump and Sewage Pump Manufacturers Association Since 1956, we are a North American trade organization of sump, effluent, and sewage pump manufacturers
More informationExisting Condition: (Date: May 2000) Evaluation: In good working condition but the facility is not secured.
Atauro 05 - Tangke Cementerio 1998 AusAID Facility: Service reservoir Structure: Concrete Shape: Rectangular Dimension: 2.5m x 3.5m x 2.3m Capacity: 15m 3 Function: Storage Source of Water: Tulai spring
More informationSpecifying Pumps Why Do Pumps Fail.
Specifying Pumps Why Do Pumps Fail 1 www.sspma.org SSPMA Sump and Sewage Pump Manufacturers Association Since 1956, we are a North American trade organization of sump, effluent, and sewage pump manufacturers
More informationPresentation Outline ENERGY CONSERVATION: 10/20/2017
Presentation Outline ENERGY CONSERVATION: Common Sense Methods for Lightening the Load v 2.0 PREPARED FOR: New Jersey Water Association 2017 Fall Conference PRESENTER: David J. Applegate, P.E., T3, W3
More informationSECTION COOLING TOWER
PART 1 GENERAL 1.1 SECTION INCLUDES A. Mechanical induced draft Cooling Tower B. Controls C. Ladder and handrails 1.2 REFERENCES SECTION 23 65 00 COOLING TOWER A. ANSI/AFBMA 9 - Load Rating and Fatigue
More informationTYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:
Effluent Pumps: Effluent pumps are the pumps most often used in small on-site systems. They are designed to pump effluent, the effluent flowing out of a septic tank. This effluent is relatively clear liquid
More informationPUMP STATION CHECK LIST
PUMP STATION CHECK LIST I. SITE LOCATION D. E. Location of pump station site has to be reviewed and approved by Planning Department and Department of Public Utilities. (II-V-F-1-J-i) The pump station has
More informationPermit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System
Permit for Construction of an Extension to a JEA Drinking Water Distribution System and/or JEA Wastewater Collection/Transmission System INSTRUCTIONS: This form shall be completed and submitted (in duplicate)
More informationHannah Yan. Mobile/Skype/WhatsAPP: Wechat:yhr MSP HEAVY DUTY SUMP PUMPS
Hannah Yan Email:info@deponpump.cn Mobile/Skype/WhatsAPP:+86 11 32 3669 Wechat:yhr1381 MSP HEAVY DUTY SUMP PUMPS MSP HEAVY DUTY SUMP PUMPS Vertical, shaft driven centrifugal slurry pumps. Rugged pumping
More informationMcDuff WTP High Service Pump Replacement
T E C H N I C A L M E M O R A N D U M 642-03 MCDUFF WTP HIGH SERVICE PUMP REPLACEMENT 642-03 McDuff WTP High Service Pump Replacement PREPARED FOR: PREPARED BY: Capital Budget Planning Craig Jones DATE:
More informationAll product images are indicative only General characteristics
submersible pumps PRODU AALOGUE 0 Multi-channel open impeller All product images are indicative only General characteristics Multi-channel open impeller motor power, 9, kw poles / / 6 discharge DN80 DN50
More informationDe-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application.
Issue 3 / 17 SUBMERSIBLE PUMPS De-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application. Email: info@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland:
More informationNo-Vault Pump Stations. Technology Innovation Solutions
No-Vault Pump Stations Technology Innovation Solutions Product Overview EXCEL FLUID GROUP is a premier manufacturer of complete vault-less pump station enclosures that give you full access and control
More informationHydraulics Laboratory Experiment Report
Hydraulics Laboratory Experiment Report Name: Ahmed Essam Mansour Section: Title: "1", Monday 2-5 pm Centrifugal Pumps Date: 27 November, 2006 Objectives: To study the performance of a centrifugal pumps
More informationChanging The Way Water Moves Ft Lauderdale, FL
Changing The Way Water Moves Ft Lauderdale, FL 954-540-2863 www.globalgreenlifts.com WELCOME TO THE ENERGY SAVING GREEN LIFT STATION DESIGN Introducing the wastewater lift station design that is sure to
More informationPRICE BID FOR. Processing zone of Special Economic Zone, MAHINDRA WORLD CITY (JAIPUR) LIMITED, JAIPUR MWCJL/HR/INFRA/HC ZONE/STP/ /T-32
PRICE BID FOR DESIGN, SUPPLY, CONSTRUCTION, ERECTION, COMMISSIONING AND OPERATING OF (PHASE I) 3000 M3/DAY CAPACITY SEWAGE TREATMENT PLANT BASED ON ADVANCED SEQUENTIAL BATCH REACTOR TECHNOLOGY AT MAHINDRA
More information& ACCESSORIES WASTEWATERTER PUMPSUMPS -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS
WASTEWATERTER PUMPSUMPS & ACCESSORIES -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS Weber Industries, Inc 8417 New Hampshire Ave. St. Louis, MO 63123
More informationCity of Brookings. Sanitary Sewer Collection Design Standards
City of Brookings (Brookings Municipal Utilities - BMU) Revision Date: September 6, 2016 Brookings Municipal Utilities 525 Western Avenue P.O. Box 588 Brookings, SD 57006-0588 (605) 692-6325 i Table of
More informationReclaimed Water Treatment, Distribution, Pumping and Storage Engineering Report Form
Oklahoma Department of Environmental Quality Water Quality Division Phone: 405-702-8100 Construction Permitting Section 707 N. Robinson, OKC, OK 73102-6010 P.O. Box 1677, OKC, OK 73101-1677 Reclaimed Water
More informationSEWAGE PUMPS CUTTER PUMPS NON-CLOG PUMPS DRAINAGE PUMPS GRINDER PUMPS SINGLE CHANNEL PUMPS VORTEX SEWAGE PUMPS VORTEX & AGITATOR PUMPS
SEWAGE PUMPS CUTTER PUMPS NON-CLOG PUMPS DRAINAGE PUMPS GRINDER PUMPS SINGLE CHANNEL PUMPS VORTEX SEWAGE PUMPS VORTEX & AGITATOR PUMPS 50 Hz SUBMERSIBLE SEWAGE PUMPS Robust Design, Real Quality Designed
More informationPublic Information Centre No. 1
Public Information Centre No. 1 City of Timmins Schedule B Class Environmental Assessment for the WHITNEY TISDALE SANITARY SYSTEM UPGRADES Welcome Please Sign In Class EA Process & Public Consultation
More informationu m p a n d u m p i n g y s t e m p e c i a l i s t s i n c e
P P S S S u m p a n d u m p i n g y s t e m p e c i a l i s t s i n c e 1 9 6 2 Ft Worth Waco Austin Houston San Antonio 2 3 Vertical Turbine Fabricated Steel Components Smith Pump specializes in engineered
More informationProgressive Design Build Services for the th Street, 6217 Wilson Blvd., 7703 Blanding Blvd. and Robitzsch Ln. Wastewater Pump Station
Progressive Design Build Services for the 5104 118th Street, 6217 Wilson Blvd., 7703 Blanding Blvd. and Robitzsch Ln. Wastewater Pump Station Rehabilitation or Replacement for Solicitation Number 025-18
More informationFlygt 3045, 50Hz. Technical Specification
Flygt 3045, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating and
More informationSECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 22 13 33 PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS SPEC WRITER NOTES: 1. Delete between //----// if not applicable to project. Also delete any other item or paragraph
More informationSECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS
SECTION 22 14 36 PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also delete any other item or paragraph
More informationFlygt C-pumps Submersible waste and raw water pumps
Flygt C-pumps 3068 3800 Submersible waste and raw water pumps Flygt submersible pumps for a variety of applications Submersibles Flygt pumps operate directly in the liquid being pumped, which means they
More information6" RETURN FROM PUMP RESERVOIR LABELED "ph" 6" RECIRCULATION SUCTION (TYP OF 2) 6" BUTTERFLY VALVE (TYP OF 2) 2" RECIRC PUMP TO FILTER RECIRCULATION PUMP 2" PUMP TO WASTE CHLORINE FEEDER ELECTRICAL PANEL
More informationSCRUBBER SUMP SYSTEM PROCESS DESCRIPTION Document No
BWN-3/4-02300.601 Rev. 0 Process Description Plant Bowen /s/ Gary Smith Approved Plant Review Board /s/ Tim Crump Approved Operations Manager /s/ Tim Banks Approved Plant Manager Date: 08-20-2010 PLANT
More informationHAZOP Checklist for Sewage Treatment Plant
HAZOP Checklist for Sewage Treatment Plant CHECKLIST 1.0 Overall Layout of Treatment Plant 1.1 General Layout Property are fenced and gated and the fence height. State where these problems/impacts occur
More informationAALSO Summary of Formulas needed for Levels I, II and III.
AALSO Summary of Formulas needed for Levels I, II and III. The information provided below is used in the math portion of the proficiency exams. Please take time to review and learn how to use these formulas
More informationDIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS
DIVISION 33 UTILITIES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: The work specified in this Section consists of providing an Environmental One grinder pump(s) unit with tank, internal piping and
More informationNUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A
TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 DATA SHEET A ANNEXURE - A Sr. Item Description Sr. Item Description A. GENERAL DATA B. PUMP DUTY PARAMETERS 1. System Name 1. Rated capacity,
More informationGREEN PROJECT RESERVE BUSINESS CASE CITY OF BROKEN ARROW WATER SUPPLY IMPROVEMENTS PROJECT
GREEN PROJECT RESERVE BUSINESS CASE CITY OF BROKEN ARROW WATER SUPPLY IMPROVEMENTS PROJECT July, 2011 The Oklahoma Water Resources Board (OWRB) requires a Business Case be made for projects or certain
More informationAPPLICATION FOR GRAVITY SEWER SERVICE CONNECTION
APPLICATION FOR GRAVITY SEWER SERVICE CONNECTION Permit Number ---------------------------- TO: Board of Sewer Commissioners 41 Highland Avenue Cohasset, MA 02025 (To be completed by Homeowner.) APPLICANT:
More informationEngineering Design Center. Standard Drawings. 1st Edition -January 2016
Engineering Design Center Standard Drawings 1st Edition -January 2016 Golden State Water Company Standard Drawings 1/11/2016 Table of Contents PART A STANDARD DRAWINGS Section I Pipeline Construction P-1
More informationDewatering solutions that work
Dewatering solutions that work COMPLETE RENTALS SERVICES FOR SEWAGE BY-PASS, CONSTRUCTION DEWATERING, FLOOD DRAINAGE, SURFACE IRRIGATION, AND MINE DEWATERING Pumps, Mixers, Generators, and Accessories
More informationFlygt 3057, 50Hz. Technical Specification
Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating and
More informationSECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT
SECTION 23 05 12 GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete
More informationISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION
ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION FIBERGLASS PACKAGE LS SITE PLAN PAGE No. 111 NUMBER: FG-LS-SITE-PLN FIBERGLASS PACKAGE LS PIPING PLAN PAGE No. 112 NUMBER: FG-LS-PIPE-PLN
More informationRugged, reliable and efficient sump pumps... your assurance of a dry basement!
Rugged, reliable and efficient sump pumps... your assurance of a dry basement! TITAN sump pumps provide the performance, value and simplicity you need for your home, farm, cottage or business...count on
More informationPage - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB
SUBMERSIBLE MULTISTAGE PUMPS SB 3 CONTENENTS 50 Hz Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB 3 15-23-30-45 203 - CONSTRUCTIONS
More informationPUMPS FOR MUNICIPAL APPLICATIONS. Gorman-Rupp provides wastewater-handling solutions for all your treatment system s pumping needs.
GORMAN-RUPP PRODUCTS MUNICIPal Wastewater treatment PUMPS FOR MUNICIPAL APPLICATIONS Gorman-Rupp provides wastewater-handling solutions for all your treatment system s pumping needs. Providing quality
More informationTable of Contents. Foreword... xvii Executive Summary... xxi. Chapter One Pump Fundamentals, 1
Foreword................................................ xvii Executive Summary........................................ xxi Chapter One Pump Fundamentals, 1 1.1 Introduction..........................................
More informationCHAPTER 5 SEWAGE PUMPS AND LIFT STATIONS
15 October 1973 FM 5-163 CHAPTER 5 SEWAGE PUMPS AND LIFT STATIONS 5-1. General Pumps for lifting sanitary sewage, storm water, and plant-unit effluents are usually high-capacity, low-head types with large
More informationADDENDUM NO. 6 ADDENDUM TABLE OF CONTENTS
ADDENDUM TABLE OF CONTENTS Addendum Instructions (Total 13 pages) Changes to Specifications and Contract Documents Changes to Contract Drawings Questions by Contractors Addendum Attachments Attachment
More informationFreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS
FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS I. GENERAL All FreezeFree Automated Anti-Icing Systems shall be designed and manufactured by Energy Absorption Systems, Incorporated, of
More informationPorter Creek Water Reservoir in Whitehorse, YK
Porter Creek Water Reservoir in Whitehorse, YK Description: Buried 4000 cubic meter capacity reinforced concrete water reservoir, 16 sided in plan and 6.5 m height, complete with roof hatch, ladder and
More informationAttachment N o F Control & Monitoring
Attachment N o F Control & Monitoring Attachment F1: Treatment, Abatement and Control Systems Air There is no treatment or abatement systems required for the minor air emission points or the potential
More informationPittsburgh Water Treatment Plant Projects. by Jay R. Lucas, P.E. Senior Project Manager
Pittsburgh Water Treatment Plant Projects by Jay R. Lucas, P.E. Senior Project Manager Who Is American Water We are the largest publicly traded water and wastewater utility in the United States Broad national
More informationTown of New Castle, New Hampshire Sewer Infrastructure Evaluation
Town of New Castle, New Hampshire Sewer Infrastructure Evaluation March 2016 EXECUTIVE SUMMARY The Town of New Castle (Town) is working collaboratively with the City of Portsmouth (City) to consider options
More informationSMP. Single-channel closed impeller. submersible pumps PRODUCT CATALOGUE General characteristics
submersible pumps PRODU AALOGUE 04 Single-channel closed impeller All product images are indicative only General characteristics Single-channel closed impeller motor power,0 kw 6,4 kw poles / 4 / 6 discharge
More information2014 Annual Compliance Report Operation & Maintenance Of Tara Wastewater System
2014 Annual Compliance Report Operation & Maintenance Of Tara Wastewater System March 2015 Prepared for: Municipality of Arran-Elderslie 1925 Bruce Road 10 Box 70 Chesley, ON N0G 1L0 Prepared by: GSS Engineering
More informationDewatering solutions that work
Dewatering solutions that work COMPLETE RENTALS SERVICES FOR SEWAGE BY-PASS, CONSTRUCTION DEWATERING, FLOOD DRAINAGE, SURFACE IRRIGATION AND MINE DEWATERING Pumps, Mixers, Generators and Accessories Sewage
More informationCITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413
Page: 1 of 5 CITY OF PANAMA CITY BEACH Utilities Administration & Engineering Offices 116 South Arnold Road Panama City Beach, FL 32413 COMMERCIAL/RESIDENTIAL UTILITY PLAN COMPLETENESS CHECK LIST Updated
More informationFLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.
FLUID FLOW - PUMPS 4 3 Control valve Suction Section Discharge Section Two main types of pumps: Positive Displacement pumps Centrifugal pumps ChE 453 - Design I FLUID FLOW - PUMP PERFORMANCE Mechanical
More informationAvailable In Stainless Steel Epoxy Coated Steel Fiberglass
Available In Stainless Steel Epoxy Coated Steel Fiberglass Sanitary Wastewater Storm Water Industrial Processed Waste Cooling Water The Pumping World s One Stop Shop! Overview The Pumping Single-source
More informationPUMP SELECTION CONTROLS. Winfred RONO, June 27, 2018
PUMP SELECTION & CONTROLS Winfred RONO, June 27, 2018 Objective of the Training 1. Proper pump sizing and selection 2. To be able to ask the right questions 3. To be able to sell without fear 2 D&S PRODUCT
More informationA. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.
Page 221429-1 SECTION 221429 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationTechnical specification. Flygt N 3301, 50 Hz
Technical specification Flygt N 3301, 50 Hz 4G50 mm 2 4G70 mm 2 Y/D start SUBCAB 7G6+2x1,5 mm 2 Monitoring equipment Thermal contacts opening temp. 140 C Leakage sensor in inspection chamber FLS Material
More informationLiving up to our quality and performance commitments
Living up to our quality and performance commitments ADVANCED PRODUCT TESTING AT OUR EMMABODA FACILITY Living up to our performance commitments As the leading manufacturer of pumps and mixers for all kinds
More information