Acid Waste Piping Systems

Size: px
Start display at page:

Download "Acid Waste Piping Systems"

Transcription

1 Acid Waste Piping Systems INDUSTRIAL SYSTEMS YOUR LAB SPECIALIST Enfield TM Electrofusion Acid Waste Systems FRPP & NRFPP Labline Mechanical-Joint Acid Waste System FRPP Plenumline TM Mechanical Joint Acid Waste System FR-PVDF Encase TM Double Containment System PP & FRPP Neutratank Neutralization Tanks HDPE & PP Floway TM Drains PP Neutrasystem2 TM Monitoring We build tough products for tough environments.

2 Integrated Total Laboratory SOLUTIONS For more than 30 years, IPEX has been supplying industrial, commercial, school and hospital laboratories throughout North America with high-quality, easy-to-install acid waste systems designed to handle a wide variety of chemicals and ph levels. Our comprehensive line of dedicated acid waste conveyance, neutralization and monitoring systems offers innovative features not available with any other system. In fact, IPEX Enfield TM electrofusion and Labline mechanical joint systems have long been recognized as the industry benchmark for performance and reliability, and are among the most widely specified systems in North America. Also available through IPEX is the next generation, E-84 compliant Plenumline TM system, made of flame retardant PVDF for extremely demanding applications such as return-air plenums. The complete range of IPEX integrated total solutions for acid waste applications also includes our Neutratank neutralization tanks, Neutrasystem2 TM ph monitoring system and Floway TM drains, as well as Encase TM double containment systems. Increasingly stringent government and industry standards, along with the widespread public desire to minimize the impact of chemical waste on the environment, continues to make compliance a vital concern for our customers. IPEX offers a complete range of pipe and fittings in a variety of materials to suit any acid waste application. With the ability to handle intermittent temperatures from -10ºF to 212ºF and self extinguishing properties, our flame-retardant polypropylene (FRPP) systems are ideally suited for all above-grade laboratory applications.

3 With identical chemical/temperature properties for belowgrade installations, our non-flame-retardant polypropylene (NFRPP) is the material of choice. Specifically designed and approved for use in return-air plenums or higher temperature/higher concentration applications, IPEX offers a flame-retardant polyvinylidenefluoride (FR-PVDF) system. Compared to conventional ductile iron and borosilicate glass systems, all three IPEX thermoplastic materials exhibit excellent resistance to a wide range of chemicals with ph from 1 to 13 and will not corrode, rust, pit or scale and offer much greater flexibility/impact resistance. The result: far easier installations, low maintenance and substantial cost savings over the life of the systems. YOUR FULL-SPECTRUM ACID WASTE SPECIALIST

4 ENFIELD TM ELECTROFUSION ACID WASTE SYSTEMS Enfield electrofusion fittings are molded with an integral resistance wire in the socket, with jointing completed by energizing the resistance wire via a microprocessor controlled Enfusion Control Unit. The result of these innovations is an unparalleled level of joint reliability and repeatability. Enfield has proven over time that it produces the optimum level of performance where it matters most - at the joint interface. It offers unprecedented control of jointing - controlled fit, controlled temperature and controlled time. i Enfield offers polypro fittings, constructed with a heavy gauge resistance wire that is integrally molded into the socket. These are considered to be the premier fittings on the market. ADVANTAGES POSITIVE RELIABLE JOINTS made in 2 minutes - installation time is reduced SEVERAL JOINTS CAN BE MADE AT ONE TIME PROVEN RELIABILITY for over a decade ENFIELD IS MANUFACTURED FROM POLYPROPYLENE which has an operating temperature range from -10ºF to 212ºF. *This allows systems to be flushed with boiling water HEAVY GAUGE RESISTANCE WIRE molded into sockets - no loose components, controlled fusion of joints EASY CONNECTING heavy duty socket terminal posts complete with protection ears MICROPROCESSOR CONTROLLED ENFUSION UNIT ensures secure joints and joint repeatability MATCHED SYSTEM - high quality pipe and fittings are matched to give ease of installation and long term reliability EASY TO INSTALL - even in difficult areas INSTALLED COST 50% LESS THAN GLASS BREAKAGE FACTOR ELIMINATED MAINTENANCE FREE

5 SHORT FORM SPECIFICATIONS GENERAL Acid waste drain and vent system, as shown on drawings, shall be NSF listed and CSA certified Schedule 40, polypropylene as manufactured by IPEX. System to include pipe supplied in 10 ft. lengths (or 20 ft lengths if NFRPP is specified), fittings, traps and neutralization tanks from the same manufacturer. It shall also include recommended adapters to connect to other piping materials, where applicable. MATERIAL Pipe shall be made from NSF listed Type 110 or 210, flame retardant polypropylene conforming to ASTM D4101, with a maximum average flame spread of zero seconds and a maximum extent of burning of 13 mm, in accordance with ASTM D635. Matched fittings shall be made from NSF listed flame retardant polypropylene with average maximum burn time of 80 seconds and maximum extent of burning of 20 mm in accordance with ASTM D635. If NFRPP pipe is specified, it shall be made from NSF 14 listed and CSA certified Schedule 40 PP as manufactured by IPEX. Pipe shall comply with ASTM F1412 and material used shall comply with the material requirements of ASTM D4101. FITTINGS Fittings shall be NSF listed and have an integral heavy gauge, nickel/chrome electrical resistance wire molded in place in the fitting body. Copper wire elements, loose wire or other loose joint components, are prohibited. Fittings shall be Enfield or approved equal. JOINTS Connections between polypropylene pipe and fittings shall be made using the Enfield joint. All joints shall have a fusion cycle controlled by a microprocessor operated, waterproof, Enfusion control unit equipped with input and output voltage sensors, ambient temperature sensors to automatically adjust fusion time and audible alarms to indicate cycle interruptions and completion of the joining process. The unit shall be capable of fusing multiple joints and with a minimum capability of eight 2" joints with the same fusion time as a single joint. Connections between polypropylene and other piping materials shall be made using Enfield adapters according to manufacturer s (IPEX) recommendations. All electrofusion machines shall be third party certified by UL and CSA. INSTALLATION AND TESTING Installation and testing shall be in accordance with the contract drawings, the manufacturer s recommendations and the local plumbing codes. Testing with compressed air is prohibited. The entire system shall be installed free of stress and in proper alignment. Horizontal supports shall provide a wide bearing area and be free of burrs or sharp edges. Support spacings shall be in accordance with the manufacturer s recommendations and local plumbing codes. Vertical piping shall have riser clamps at each floor. Pipe supports should be installed so that horizontal piping is in uniform alignment and with a uniform slope of at least 1/8" per foot or in accordance with the local plumbing codes.

6 ENFIELD TM ELECTROFUSION ACID WASTE SYSTEMS PRODUCT SELECTION CHART AW POLYPROPYLENE PIPE FLAME RETARDANT Sch 40 AW POLYPROPYLENE PIPE FLAME RETARDANT Sch 40 10' Lengths 1-1/2 W W W W W W W W ' Lengths Note: 20' Schedule 40 FR pipe is a non-stock item available upon special request. 1-1/2 W W W W W W W W AW POLYPROPYLENE PIPE FLAME RETARDANT Sch /2 WT WT WT WT ' Lengths AW POLYPROPYLENE PIPE BLACK NON-FLAME RETARDANT Sch /2 WB WB WB WB ' Lengths 6 WB WB WB WB AW POLYPROPYLENE PIPE FLAME RETARDANT Sch 80 20' Lengths 1-1/2 WT WT WT WT ' Lengths Note: 20' Schedule 80 FR pipe is a non-stock item available upon special request. AW POLYPROPYLENE PIPE BLACK NON-FLAME RETARDANT Sch /2 WB WB WB WB WB WB WB WB BLACK NON-FLAME RETARDANT ENFIELD COUPLING 2 L162B L163B L164B L166B L168B L1610B L1612B COUPLING EJ 1-1/2 L L L L L L L L IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

7 PRODUCT SELECTION CHART FABRICATED REPAIR COUPLING EJ 2 L162R L163R L164R L166R L168R FABRICATED 1/8 BEND EJ 8 L L L /4 BEND (90 ) EJ 90º SWEEP EJ 1-1/2 L /2 L L L L L L /4 BEND (90 ) EJ x Sp 1-1/2 L L º SWEEP EJ x Sp 1-1/2 L L L L L /4 BEND EJ x Ln 1-1/2 L291 A /8 BEND EJ 1-1/2 L L L L L FABRICATED 1/4 BEND (90 ) EJ 8 L L L /8 BEND EJ x Sp 1-1/2 L L L L SANITARY TEE EJ 1-1/2 L L L L L IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

8 ENFIELD TM ELECTROFUSION ACID WASTE SYSTEMS PRODUCT SELECTION CHART FABRICATED SANITARY TEE EJ 6 L L L L REDUCING DOUBLE SANITARY TEE EJ 2 x 1-1/2 L x 1-1/2 L x 2 L x 3 L REDUCING SANITARY TEE EJ 2 x 1-1/2 L x 1-1/2 L x 2 L x 2 L *4 x 3 L * Fabricated 45º WYE EJ 1-1/2 L L L L L FABRICATED REDUCING SANITARY TEE EJ 6 x 2 L x 4 L x 3 L x 4 L x 6 L x 3 L x 4 L x 6 L x 8 L x 4 L x 6 L x 8 L x 10 L DOUBLE SANITARY TEE EJ *1-1/2 L L L L * Fabricated FABRICATED 45º WYE EJ REDUCING WYE EJ 8 L L L x 1-1/2 L x 1-1/2 L x 2 L x 1-1/2 L x 2 L x 3 L x 1-1/2 L x 2 L x 3 L x 4 L

9 PRODUCT SELECTION CHART FABRICATED REDUCING WYE EJ 8 x 2 L x 3 L x 4 L x 6 L x 3 L x 4 L x 6 L x 8 L x 3 L x 4 L x 6 L x 8 L x 10 L COMBINATION WYE & 1/8 BEND (Long Turn Wye) EJ 1-1/2 L L L L L FABRICATED COMBINATION WYE & 1/8 BEND EJ 8 L L L REDUCING COMBINATION WYE & 1/8 BEND EJ 2 x 1-1/2 L x 1-1/2 L x 2 L x 1-1/2 L x 2 L x 3 L x 1-1/2 L x 2 L x 3 L x 4 L FABRICATED REDUCING COMBINATION WYE & 1/8 BEND EJ 8 x 3 L x 4 L x 6 L x 3 L x 4 L x 6 L x 8 L x 3 L x 4 L x 6 L x 8 L x 10 L FABRICATED DOUBLE 45º WYE EJ 2 L L L L L L L

10 ENFIELD TM ELECTROFUSION ACID WASTE SYSTEMS PRODUCT SELECTION CHART REDUCING DOUBLE 45º WYE EJ *2 x 1-1/2 L x 4 L * Fabricated REDUCING TRUE WYE EJ 2 x 1-1/2 L x 2 L x 3 L FABRICATED REDUCING DOUBLE 45º WYE EJ 3 x 2 L x 2 L x 3 L x 6 L x 4 L x 6 L x 8 L x 4 L x 6 L x 8 L x 10 L CLEANOUT Sp 1-1/2 L L L L *6 L *Fabricated CLEANOUT PLUG Male Thread 1-1/2 L241A L242A L243A L244A FABRICATED DOUBLE COMBINATION WYE & 1/8 BEND EJ 2 L L L L CLEANOUT W/ BRASS PLUG Sp 1-1/2 L L L L FABRICATED REDUCING DOUBLE COMBINATION WYE & 1/8 BEND EJ 3 x 2 L x 2 L FABRICATED CLEANOUT TEE EJ 1-1/2 L L L L L TRUE WYE EJ 1-1/2 L L

11 PRODUCT SELECTION CHART FABRICATED CAP EJ 1-1/2 L L L L L L L L FLANGE - ASA 150 EJ 1-1/2 L L L L L FABRICATED FLANGE - ASA 150 EJ 8 L L L REDUCING BUSHING Sp x EJ 2 x 1-1/2 L ** 3 x 1-1/2 L x 2 L ** 4 x 1-1/2 L x 2 L x 3 L x 1-1/2 L x 3 L x 4 L x 3 L x 4 L x 6 L x 4 L x 6 L x 8 L x 4 L x 6 L x 8 L x 10 L ** Discontinued when stock is depleted ADAPTER FEMALE Thread x LN FABRICATED BLIND FLANGE - ASA L L L /2 L ADAPTER EJ x LN 1-1/2 L MALE ADAPTER EJ x Male Thread 1-1/2 L L

12 ENFIELD TM ELECTROFUSION ACID WASTE SYSTEMS PRODUCT SELECTION CHART FEMALE ADAPTER EJ x Female Thread 1-1/2 L L P TRAP - 2 PIECE EJ 1-1/2 L L Shipped as 2 pieces GLASS ADAPTER EJ x Bead 1-1/2 L L L L FABRICATED P TRAP - 2 PIECE EJ 8 LT LT Shipped as 2 pieces NO HUB ADAPTER EJ x Sp P TRAP - 3 PIECE EJ 1-1/2 L LT L LT L LT L Shipped as 3 pieces 3" or 12" FRPP TAIL PIECE ADAPTER 1-1/2 x 3 W /2 x 12 W C/W SPIG X BRASS COMPRESSION RING PIPE CLIP 1-1/2 W W /2" x 12" FRPP SWIVEL SINK STRAINER ADAPTER Spg x Female Thread 1-1/2 x 12 W UNIVERSAL TRAP - SOLID BASE, P Type EJ x Female Thread 1-1/2 L /2 L C/W VITON GASKET FRPP SWIVEL SINK STRAINER ADAPTER Spg x Female Thread 1-1/2 W *1-1/2 W551G C/W VITON GASKET *Pregrooved for Labline. Nut and Olive are extra. UNIVERSAL TRAP - CLEAR BASE, P Type EJ x Female Thread 1-1/2 L /2 L

13 PRODUCT SELECTION CHART UNIVERSAL TRAP - SOLID BASE, S Type EJ 1-1/2 L STAINLESS STEEL T HANDLE FOR HUB CLAMPS 1-1/2 to 12 L2610T UNIVERSAL TRAP - CLEAR BASE, S Type EJ 1-1/2 L OIL IMPREGNATED BRASS BUSHINGS FOR CLAMPS 1-1/2 to 12 L2610B CONNECTOR CABLE - Current Style Machine - L FABRICATED EXPANSION JOINT 3 L L L CONNECTOR CABLE - Old Style Machine - L CONNECTOR CABLE - EZ Connector Cable ENFUSION CONTROL UNIT - Complete Kit - EHHL Kit includes hub clamps, 1 1/2" thru 6", connector cable & 5' link cable. ENFUSION HUB CLAMP - New T Bar Handle & Bushing 1-1/2 L L L L L L L L L LINK CABLE c/w EZ CONNECTOR 2 ft. EZ L ft. EZ L ft. EZ L ft. EZ L LINK CABLE c/w LINK LEAD 5 ft. L ft. L ft. L FUSES 16 AMP P MILAMP L MILAMP L

14 LABLINE MECHANICAL JOINT ACID WASTE SYSTEMS Labline (Mechanical Joint) has displaced the more expensive and difficult to install glass and metal systems. Gone is the need for fusing, caulking or welding of joints. Joining of the Labline System is complete in just 30 seconds and once the nut is locked into place, the end-user is assured of many years of trouble-free service. Yet, because it is a mechanical joint, the system can be easily dismantled and re-used, making it ideal for modular designs and for systems that may require re-modeling in the future. i Both Labline and PlenumlineTM contain no-heat Elastolives TM for quick installation and high performance. ADVANTAGES 30 SECOND JOINTING - save on installation time PROVEN RELIABILITY for over 30 years LABLINE IS MANUFACTURED FROM POLYPROPYLENE which has an operating temperature range from -10ºF to 212ºF.* This allows systems to be flushed with boiling water ALL PLASTIC CONSTRUCTION - no galvanic action, electrolysis or corrosion in the joint SIMPLE, INEXPENSIVE, NON-TEMPERAMENTAL TOOLS EASY TO INSTALL, even in difficult areas MASTERED BY PLUMBERS IN MINUTES. No pre-heating required to install olive SYSTEM CHANGES DURING INSTALLATION CAN BE DONE WITHOUT SPOILING FITTINGS CAN BE DISASSEMBLED AND RE-USED IDEAL FOR MODULAR SYSTEMS IDEAL FOR REMODELING MATCHED SYSTEM - high quality pipe and fittings are matched to give ease of installation and long term reliability

15 SHORT FORM SPECIFICATIONS GENERAL Acid waste drain and vent system, as shown on drawings, shall be NSF listed, Schedule 40, polypropylene as manufactured by IPEX to include pipe supplied in 10 ft. lengths (or 20 ft lengths if NFRPP is specified), and matched fittings, traps and neutralization tanks from the same manufacturer. It shall also include recommended adapters to connect to other piping materials, where applicable. MATERIAL Pipe shall be made from NSF listed Type 110 or 210, flame retardant polypropylene conforming to ASTM D4101, with a maximum average flame spread of zero seconds and a maximum extent of burning of 13 mm, in accordance with ASTM D635. Matched fittings shall be made from NSF listed flame retardant polypropylene with average maximum burn time of 80 seconds and maximum extent of burning of 20 mm in accordance with ASTM D635. If NFRPP pipe is specified, it shall be made from NSF 14 listed and CSA certified Schedule 40 PP as manufactured by IPEX. Pipe shall comply with ASTM F1412 and material used shall comply with the material requirements of ASTM D4101. FITTINGS Fittings shall be NSF listed, be of all plastic construction and be designed to lock into a machined groove on the mating piping. All fittings shall have integrally molded union connections. No metallic grab rings or clamps shall be allowed. Fittings containing EVA (ethylene vinyl acetate) are strictly prohibited. Couplings shall not be added to make mechanical joint fittings. Fittings shall be Labline or approved equivalent. JOINTS Connections between polypropylene pipe and matched fittings shall be made using the Labline Joint. INSTALLATION AND TESTING Installation and testing shall be in accordance with the contract drawings, the manufacturer s recommendations and the local plumbing codes. Testing with compressed air is prohibited. The entire system shall be installed free of stress and in proper alignment. Horizontal supports shall provide a wide bearing area and be free of burrs or sharp edges. Support spacings shall be in accordance with the manufacturer s recommendations and local plumbing codes. Vertical piping shall have riser clamps at each floor. Pipe supports shall be installed so that horizontal piping is in uniform alignment and with a uniform slope of at least 1/8" per foot, or in accordance with the local plumbing codes.

16 LABLINE MECHANICAL JOINT ACID WASTE SYSTEMS PRODUCT SELECTION CHART COUPLING 1-1/2 W W W W /8 BEND (45 ) 1-1/2 W W W W LOOSE NUT 1/8 BEND (45 ) MJ x LN 1-1/2 W W W W /4 BEND (90 ) 1-1/2 W W W W LOOSE NUT 1/4 BEND MJ x LN 1-1/2 W W W W SANITARY TEE 1-1/2 W W W W REDUCING SANITARY TEE 2 x 1-1/2 W x 1-1/2 W x 2 W x 1-1/2 W x 2 W x 3 W CLEANOUT TEE 1-1/2 W W W W º WYE 1-1/2 W W W W REDUCING 45º WYE 2 x 1-1/2 W x 1-1/2 W x 2 W x 1-1/2 W x 2 W x 3 W COMBINATION WYE & 1/8 BEND 1-1/2 W W W W All Labline fittings are furnished assembled with Olives and Union Nuts. IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

17 PRODUCT SELECTION CHART REDUCING COMBINATION WYE & 1/8 BEND 2 x 1-1/2 W x 1-1/2 W x 2 W x 1-1/2 W x 2 W x 3 W REDUCING COUPLING LN x MJ 2 x 1-1/2 W x 1-1/2 W3931* x 2 W3932* x 1-1/2 W3941* x 2 W3942* x 3 W * Loose nut not furnished DOUBLE WYE 1-1/2 W W W W THREADED ADAPTER Male Thread x Female Thread 1-1/2 x 1-1/4 W /2 x 1-1/2 W REDUCING DOUBLE WYE 2 x 1-1/2 W x 1-1/2 W x 2 W x 1-1/2 W x 2 W x 3 W DOUBLE WYE & 1/8 BEND 1-1/2 W W W W REDUCING DOUBLE WYE & 1/8 BEND 2 x 1-1/2 W x 1-1/2 W x 2 W x 1-1/2 W x 2 W x 3 W MALE ADAPTER MJ x Male Thread 1-1/2 W141T W W W FEMALE ADAPTER MJ x Female Thread 1-1/2 W W GLASS ADAPTER MJ x Bead 1-1/2 W W W W NO HUB ADAPTER MJ x Spigot 1-1/2 W W W W All Labline fittings are furnished assembled with Olives and Union Nuts. IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

18 LABLINE MECHANICAL JOINT ACID WASTE SYSTEMS PRODUCT SELECTION CHART CLEANOUT PLUG VENT LOOP U BEND P TRAP - 2 PIECE 1-1/2 W W W W /2 W W /2 W W UNIVERSAL TRAP FEMALE Thread x MJ 1-1/2 W /2 W Transparent Base - W PP Base Only - W Clear Base Only - W O-ring Gasket Only - W Top Assembly For W501 & W511 UNIVERSAL TRAP, S-TYPE FEMALE Thread x MJ 1-1/2 W *1-1/2 W * Transparent Base P TRAP - 3 PIECE LONG RADIUS 1-1/2 WT WT WT WT S TRAP - 3 PIECE 1-1/2 W W SINK OUTLET w/ PLUG 1-1/2-3-3/8 W301B (Black) /2-3-3/8 W301W (White) /2-2-7/8 W311B (Black) /2-2-7/8 W311W (White) W3012B (Lock Nut For W301B) Specify Black or White RUNNING TRAP - 3 PIECE 1-1/2 W W SINK OUTLET PLUG W3011B (Black) W3011W (White) SINK OVERFLOW 1-1/2 W321B (Black) /2 W321W (White) All Labline fittings are furnished assembled with Olives and Union Nuts. IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

19 PRODUCT SELECTION CHART CUP SINK ROUND UNION NUT 6 x 4 Deep W401B /2 W x 4 Deep W W W4011B W (Plug for W401B) 4 W CUP SINK OVAL 6 x 3 W x 3 W W (Nut for W497) NO HEAT ELASTOLIVE YELLOW 1-1/2 W221NH W222NH W223NH W224NH DILUTION TRAP 1-1/2 W * 1-1/2 W * Transparent Base GROOVING TOOL 1-1/2 W W W W COBRA PIPE CLIP PIPE CLIP * 3/ * 1/ * 3/ * / / / * Supplied without retaining bands 1-1/2 W W Obsolete when stock is depleted SPANNER 1-1/2 W W W W GROOVING TOOL & SPANNER COMBINATION SET 1-1/2 W261CS W262CS W263CS W264CS MECHANICAL JOINT LUBRICANT 1kg All Labline fittings are furnished assembled with Olives and Union Nuts. IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

20 PLENUMLINE TM MECHANICAL JOINT ACID WASTE SYSTEMS Plenumline mechanical joint acid waste systems easily displace costly and difficult-to-install glass and metal systems. With Plenumline, time-consuming methods associated with conventional heavy and brittle systems are replaced by a time proven mechanical joint that takes only 30 seconds to complete. Once the Plenumline nut is locked in place, the end-user is assured of many years of trouble-free service. In addition, mechanical joint systems can easily be dismantled and re-used, making Plenumline ideal for modular designs and future expansions. i IPEX Plenumline is a robust acid waste system, made from flameretardant PVDF thermoplastic, designed for challenging conditions, including highly restrictive return air plenum applications and hightemperature corrosive chemical waste situations. ADVANTAGES IDEALLY SUITED TO PLENUM APPLICATIONS 30-SECOND JOINTS SHORTEN INSTALLATION TIME MANUFACTURED FROM FLAME RETARDANT PVDF, which has an operating temperature range from -40 F (-40 C) to 285 F (140 C). With this high upper limit, Plenumline systems can be flushed with boiling water. ALL-PLASTIC CONSTRUCTION ELIMINATES GALVANIC ACTION, ELECTROLYSIS AND CORROSION IN THE JOINT. MODULARIZED DESIGN means Plenumline components can be disassembled and re-used. In addition, system modifications during installation can be performed without damaging fittings. HIGH-QUALITY PIPE AND FITTINGS are matched to simplify installation and extend long-term reliability. FLAME RETARDANT PVDF material exhibits a flame spread index of 5 and smoke development index of 35 as tested in accordance with ASTM E84 and UL723. EASY TO INSTALL, even in tight areas, by using simple, inexpensive tools. Mechanical joints are mastered by plumbers in minutes; no pre-heating is required to install the new blue elastolive.

21 SHORT FORM SPECIFICATIONS GENERAL Acid waste drain and vent system, as shown on drawings, shall be IAPMO listed, Schedule 40, FR- PVDF as manufactured by IPEX to include pipe supplied in 10 ft. lengths and matched fittings, traps and neutralization tanks from the same manufacturer. It shall also include recommended adapters to connect to other piping materials, where applicable. MATERIAL Pipe and fittings shall be made from Kynar , flame retardant PVDF conforming to ASTM F 1673, with a limiting oxygen index (LOI) of 60, Resin must have a vertical burn rating of 94 V-0. Kynar resin based on testing to ASTM E84 (UL 723) must have surface burning characteristics greater than or equal to a flame spread 5 and smoke development 35. FITTINGS Fittings shall be third party certified to ASTM F 1673 and ASTM E84, and IAPMO approved, be of all plastic construction and a tapered elastic retaining ring shall be designed to lock into a machined groove on the mating piping. All fittings shall have integrally molded union connections. No metallic grab rings or clamps shall be allowed. Fittings shall be Plenumline or approved equal. INSTALLATION AND TESTING Installation and testing shall be in accordance with the contract drawings, the manufacturer's recommendations and the local plumbing codes. Testing with compressed air including air booster over water is prohibited. The entire system shall be installed free of stress and in proper alignment. Horizontal supports shall provide a wide bearing area and be free of burrs or sharp edges. Support spacings shall be in accordance with the manufacturer's recommendations and local plumbing codes. Vertical piping shall have riser clamps at each floor. Pipe supports shall be installed so that horizontal piping is in uniform alignment and with a uniform slope of at least 1/8" per foot, or in accordance with the local plumbing code requirements.

22 PLENUMLINE TM MECHANICAL JOINT ACID WASTE SYSTEMS PRODUCT SELECTION CHART PIPE 1-1/2 W001P W002P W003P W004P LOOSE NUT 1/4 BEND LN x MJ 1-1/2 W291P W292P W293P W294P COUPLING SANITARY TEE 1-1/2 W161P /2 W201P W162P W202P W163P W203P W164P W204P /8 BEND REDUCING SANITARY TEE 1-1/2 W191P x 1-1/2 W2021P W192P x 1/12 W2031P W193P x 2 W2032P W194P x 2 W2042P x 3 W2043P LOOSE NUT 1/8 BEND 1-1/2 W211P CLEANOUT TEE 2 W212P /2 W2015P W213P W2025P W214P W2035P W2045P /4 BEND 1-1/2 W181P º WYE 2 W182P /2 W371P W183P W372P W184P W373P W374P All fittings are furnished assembled with Olives and Union Nuts. IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

23 PRODUCT SELECTION CHART REDUCING 45º WYE DOUBLE WYE & 1/8 BEND 2 x 1-1/2 W3721P /2 W3815P x 1/12 W3731P W3825P x 2 W3732P W3835P x 2 W3742P W3845P x 3 W3743P COMBINATION WYE & 1/8 BEND 1-1/2 W3715P W3725P W3735P W3745P REDUCING COMBINATION WYE & 1/8 BEND 2 x 1-1/2 W37251P x 1/12 W37351P x 2 W37352P x 2 W37452P x 3 W37453P MALE ADAPTER MJ x Male Thread 1-1/2 W141P W142P FEMALE ADAPTER MJ x Female Thread 1-1/2 W151P W152P CLEANOUT PLUG 1-1/2 W241P W242P W243P W244P DOUBLE 45º WYE (Fabricated) 1-1/2 W381P W382P W383P W384P U BEND for P-TRAP 1-1/2 W1011P W1012P REDUCING DOUBLE WYE 2 x 1-1/2 W3821P x 1/12 W3831P x 2 W3832P x 1-1/2 W38841P x 2 W3842P x 3 W3843P P-TRAP 2 PIECE 1-1/2 W1021P W1022P MECHANICAL JOINT LUBRICANT 1kg

24 PLENUMLINE TM MECHANICAL JOINT ACID WASTE SYSTEMS PRODUCT SELECTION CHART P-TRAP LONG RADIUS 3 PIECE 1-1/2 WT11P WT12P WT13P WT14P RUNNING TRAP 1-1/2 W1041P W1042P TAIL PIECE ADAPTER Sp x Brass Compression Ring NO HEAT ELASTOLIVE BLUE 1-1/2 x 12 W3012P /2 W221NHP W222NHP W223NHP W224NHP Note: Blue olive nut is not interchangeable with the FRPP Yellow olive nut. FABRICATED CAP 1-1/2 W641P W642P W643P W644P UNION NUT 1-1/2 W231P W232P W233P W234P LOOSE NUT - REDUCING COUPLING LN x MJ FLANGES (Fabricated) 2 x 1-1/2 W3921P x 1/12 W3931P x 2 W3932P x 2 W3942P x 3 W3943P Note: Loose Nut and Olive not furnished. 1-1/2 W361P W362P *3 W363P W364P *While quantities last, Obsolete when stock depleted GROOVING TOOL & SPANNER COMBINATION SET 1-1/2 W261CS W262CS W263CS W264CS SPANNER 1-1/2 W W W W GROOVING TOOL 1-1/2 W W W W All fittings are furnished assembled with Olives and Union Nuts. IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

25 FLOWAY TM POLYPROPYLENE FLOOR DRAINS POLYPROPYLENE FLOOR DRAINS For efficiently managing chemical spills, our Floway TM adjustable and non-adjustable polypropylene drain ports are specially designed to feed into IPEX acid waste systems. ADVANTAGES RATED FOR PEDESTRIAN TRAFFIC AND AVAILABLE IN SIZES FROM 2" TO 6". FLOWAY TM DRAINS CAN BE OPTIONALLY CONFIGURED WITH ADJUSTABLE STRAINERS, ROUND FUNNELS, SEDIMENT BASKETS AND PLAIN END OR THREADED OUTLETS. ADJUSTABLE FEATURE ALLOWS EASY LEVELING AFTER POURING OF FINISHED FLOORS

26 FLOWAY TM POLYPROPYLENE FLOOR DRAINS PRODUCT SELECTION CHART F1000 SERIES ADJUSTABLE FLOOR DRAIN Enfield 2 F1201L Labline 2 F1201W F1301P F1401P F1601P F4000 SERIES NON-ADJUSTABLE FLOOR DRAIN Enfield 2 F4201L Labline 2 F4201W F4301P F4401P F4601P F1000 SERIES ADJUSTABLE FLOOR DRAIN Enfield 2 F1202L Labline 2 F1202W F1302P F1402P F1602P w/ Sediment Basket F1000 SERIES ADJUSTABLE FLOOR DRAIN Enfield 2 F1203L Labline 2 F1203W F1303P F1403P F1603P w/ Sediment Basket and 6" Round Funnel F4000 SERIES NON-ADJUSTABLE FLOOR DRAIN Enfield 2 F4202L Labline 2 F4202W F4302P w/ Sediment Basket 4 F4402P F4602P F4000 SERIES NON-ADJUSTABLE FLOOR DRAIN Enfield 2 F4203L Labline 2 F4203W F4303P F4403P F4603P w/ Sediment Basket & 6" Round Funnel F4000 SERIES NON-ADJUSTABLE FLOOR DRAIN F1000 SERIES ADJUSTABLE FLOOR DRAIN Enfield 2 F1204L Labline 2 F1204W F1304P F1404P F1604P Enfield 2 F4204L Labline 2 F4204W F4304P F4404P F4604P w/ 6" Round Funnel Only w/ 6" Round Funnel Only IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

27 PRODUCT SELECTION CHART FLOOR CLEANOUT WITH BRASS COVER (adjustable Cleanout) SP 2 F2COB F3COB F4COB F6COB GAS TIGHT PLUG 3 P P P ALLENHEAD VANDALPROOF SCREWS Set of 3 screws P SEDIMENT BASKET STRAINER FOR F SERIES DRAINS F1000 Series P F4000 Series P GRID STRAINERS FOR F SERIES DRAINS F1000 Series P F4000 Series P MALE IRON PIPE THREADED OUTLET FPT TAP FOR PRIMING DRAIN ASSEMBLY BLANK COVER FOR F SERIES DRAINS F1000 Series P F4000 Series P / / ROUND FUNNEL 6 P IPEX components are dimensionally matched; do not install system of mixed brands without our expressed written consent.

28 HDPE & POLYPROPYLENE NEUTRALIZATION TANKS IPEX offers a complete range of Neutratank neutralization tanks as well as dilution, sampling and ph tanks for managing concentrations and ph levels in acid waste systems. Neutratanks are made of high-density polyethylene or polypropylene material with a one-piece rotationally molded, seamless construction, a bolt-down flanged top and combination access cover. Neutratanks are available in sizes from 5 gallons to 2,000 gallons to suit most potential design conditions. i Neutratanks are used for limestone neutralization of chemical waste prior to discharge into the sewer. ADVANTAGES CYLINDRICAL AND RECTANGULAR LIMESTONE NEUTRALIZATION TANKS FROM 5 TO 2000 GALLONS ARE AVAILABLE. A VARIETY OF LIDS, INLETS, OUTLETS AND ACCESSORIES ARE OFFERED. DILUTION TANKS ARE AVAILABLE IN 1, 2 AND 5- GALLON SIZES. SHORT FORM SPECIFICATIONS Contractor shall furnish and install HDPE or Polypropylene Neutralization Tank. Tank shall be rotationally molded, seamless construction with flanged top and welded or bolt down cover, as supplied by IPEX. Tank shall be Neutratank, having 100-gallon capacity complete with 3" inlet and outlet, and 1-1/2" vent connection. Tank to be 32" diameter x 42" high. Tank shall be installed in accordance with manufacturer s recommendations. Contractor shall furnish and fill the tank prior to installation with limestone chips, as supplied by IPEX, to a level just below the tank outlet. Water should be added to the tank prior to placement of the limestone chips.

29 PRODUCT SELECTION CHART Gallons Inlet/Outlet Gallons Inlet/Outlet *HDPE EZ Plain End 5 1-1/2 EZ0005A EZ0005B EZ0015B EZ0015C EZ0030B EZ0030C EZ0030D EZ0055C EZ0055D EZ0100C EZ0100D EZ0150C EZ0150D EZ0200C EZ0200D EZ0275C EZ0275D *Obsolete when stock is depleted HDPE STANDARD DOMED Plain End 5 1-1/2 T0005A T0005B T0015B T0015C T0030B T0030C T0030D T0055C T0055D T0100C T0100D T0150C T0150D T0200C T0200D T0275C T0275D T0360C T0360D T0360E T0500C T0500D T0500E HDPE HD BOLTED FLAT Plain End 5 1-1/2 HDF005A HDF005B HDF015A HDF015B HDF030A HDF030B HDF030C HDF055A HDF055B HDF100A HDF100B HDF150A HDF150B HDF200A HDF200B HDF275A HDF275B HDF360A HDF360B HDF360C HDF500A HDF500B HDF500C HDPE STEEL PEDESTRIAN Plain End 5 1-1/2 SP005A SP005B SP015A SP015B SP030A SP030B SP030C SP055A SP055B SP100A SP100B SP150A SP150B SP200A SP200B SP275A SP275B SP360A SP360B SP360C SP500A SP500B SP500C Standard Domed & HD Flat covers are not suitable for pedestrian traffic. Always use steel pedestrian covers. Neutratanks are not rated for H20 live loading. In areas requiring H20 loading, position the tank below a Department of Transportation approved manhole cover. Regular tanks and 700 to 2000 gallon cylindrical tanks are available on request.

30 HDPE & POLYPROPYLENE NEUTRALIZATION TANKS PRODUCT SELECTION CHART Gallons Inlet/Outlet Gallons Inlet/Outlet POLYPRO STANDARD DOMED Plain End 7 1-1/2 PPT005A PPT005B PPT015A PPT015B PPT030A PPT030B PPT030C PPT055A PPT055B PPT100A PPT100B PPT150A PPT150B PPT200A PPT200B PPT275A PPT275B PPT360A PPT360B PPT360C PPT500A PPT500B PPT500C POLYPRO STEEL PEDESTRIAN Plain End 7 1-1/2 PPSP005A PPSP005B PPSP015A PPSP015B PPSP030A PPSP030B PPSP030C PPSP055A PPSP055B PPSP100A PPSP100B PPSP150A PPSP150B PPSP200A PPSP200B PPSP275A PPSP275B PPSP360A PPSP360B PPSP360C PPSP500A PPSP500B PPSP500C POLYPRO HD BOLTED FLAT Plain End 7 1-1/2 PPHDF005A PPHDF005B PPHDF015A PPHDF015B PPHDF030A PPHDF030B PPHDF030C PPHDF055A PPHDF055B PPHDF100A PPHDF100B PPHDF150A PPHDF150B PPHDF200A PPHDF200B PPHDF275A PPHDF275B PPHDF360A PPHDF360B PPHDF360C PPHDF500A PPHDF500B PPHDF500C Inlet / Outlet INLET / OUTLET TANK SIZES & CONNECTION OPTIONS 1-1/2" Plain End MPT, FPT, Flanged 2" Plain End MPT, FPT, Flanged 3" Plain End MPT, FPT, Flanged 5 gal to 55 gal 5 gal to 150 gal 15 gal to 500 gal 3" Flanged 30 gal to 500 gal 4" Plain End MPT, FPT, Flanged Tank Size 30 gal to 2000 gal 6" Flanged 360 gal to 2000 gal Standard Domed & HD Flat covers are not suitable for pedestrian traffic. Always use steel pedestrian covers. Neutratanks are not rated for H20 live loading. In areas requiring H20 loading, position the tank below a Department of Transportation approved manhole cover. Regular tanks and 700 to 2000 gallon cylindrical tanks are available on request.

31 PRODUCT SELECTION CHART Gallons Inlet/Outlet Inlet/Outlet HDPE NON-ADJUSTABLE EXTENSION 5 6 to 9 PEEXT to 14 PEEXT to 24 PEEXT to 31 PEEXT to 35 PEEXT to 43 PEEXT to 43 PEEXT to 42 PEEXT to 42 PEEXT to 54 PEEXT Polypro Non-Adjustable extensions are available upon request. HDPE PLAIN END VENT HDPE MPT CONNECTION 1-1/2 PEV PEV PEV PEV /2 MPTC MPTC MPTC MPTC VARIABLE EXTENSION (2" of Vertical Adjustment) 5/7 6 to 36 ADEXT to 36 ADEXT to 36 ADEXT to 36 ADEXT to 36 ADEXT to 36 ADEXT to 36 ADEXT to 36 ADEXT to 36 ADEXT to 36 ADEXT500 - HDPE FPT CONNECTION 1-1/2 FPTC FPTC FPTC FPTC HDPE FLANGE CONNECTION 1-1/2 FLC FLC FLC FLC FLC FRP OVERWRAP 5/7 - FRPO FRPO FRPO FRPO FRPO FRPO FRPO FRPO FRPO FRPO FRP Overwrap is for tanks without extensions Please contact IPEX for FRP overwrap pricing on tanks with non-adjustable extensions. POLYPRO PLAIN END VENT 1-1/2 PEPP PEPP PEPP PEPP POLYPRO MPT CONNECTION 1-1/2 MPTPP MPTPP MPTPP MPTPP Standard Domed & HD Flat covers are not suitable for pedestrian traffic. Always use steel pedestrian covers. Neutratanks are not rated for H20 live loading. In areas requiring H20 loading, position the tank below a Department of Transportation approved manhole cover. Regular tanks and 700 to 2000 gallon cylindrical tanks are available on request.

32 HDPE & POLYPROPYLENE NEUTRALIZATION TANKS PRODUCT SELECTION CHART Inlet/Outlet Inlet/Outlet POLYPRO FPT CONNECTION 1-1/2 FPTPP FPTPP FPTPP FPTPP THREADED MANWAY 8 TMW TMW TMW POLYPRO FLANGE CONNECTION 1-1/2 FLPP FLPP FLPP FLPP NEUTRALIZING AGENT LIMESTONE BAGS 50 lbs TC NOTE: F.O.B.- Shipping Location LIMESTONE LOADING GUIDE FOR NEUTRALIZATION Tank Size Loading (lbs.)

33 MONITORING RECORDING & ALARM SYSTEMS ADVANTAGES NEMA 4X RATED, PH MONITORING SYSTEM UL 508 LISTED MONITORING AND ALARM PANEL, CHEMICALLY RESISTANT PH PROBE FOR THE CONTINUOUS SAMPLING OF THE DOWNSTREAM FLOW, WHILE KEEPING AN ACCURATE, PERMANENT RECORD OF PH DISCHARGE LEVELS AND, VISUAL AND AUDIBLE ALARMS WHICH ARE TRIGGERED IF THE SYSTEM SENSES THAT CONCENTRATIONS HAVE DRIFTED OUTSIDE PRE-SET PARAMETERS. NEUTRASYSTEM PH MONITORING & RECORDING SYSTEM Classification ph Monitor w/ Tank & Alarm TPH ph Monitor w/ Tank & Alarm & Chart TPH ph Monitor w/ Alarm TPH ph Monitor w/ Alarm & Chart TPH

34 ACCESSORIES A complete range of accessories are available for use with IPEX acid waste systems, including: Oval and round cupsinks, faucets, solids interceptors, expansion joints and a wide selection of cobra clips, dilution traps, spacers, hangers and, Transition adapters are also available for interfacing with glass or iron systems. MATERIALS AND ATTRIBUTES CHART Resin Color Schedule Length () Size () ASTM Rating Classification FRPP Green 40 10/20 1-1/2 to 12 V-1 NFRPP Black 40/ /2 to 12 V-2 FR-PVDF Blue /2 to 4 V-0 Self extinguishing. Does not support combustion after flame is removed. Suitable for locations where no burning classification is required. Self extinguishing. Meets ASTM E-84. Suitable for areas such as return-air plenums and other specialized applications. IPEX acid waste systems are designed and manufactured to meet or exceed the requirements of the following standards organizations. A comprehensive list of compliance approvals is available on request. Consult the IPEX Chemical Resistance Guide, available at ipexinc.com, for compatibility of our acid waste systems with over 900 chemicals, at a full range of temperatures and concentrations.

35 INDUSTRIAL PRODUCTS Xirtec 140 PVC Corzan CPVC 1/2" 24" (15mm 600mm) XIRTEC 140 : PVC Sch. 40 & 80 pipe & fittings systems. CORZAN : CPVC Sch. 80 pipe & fittings systems cell classification & PROCESS PIPING SYSTEMS Guardian TM Carrier: 1/2" 12" (15mm 300mm) Containment: 2" 18" (50mm 450mm) Vinyl double containment and leak detection system in tough industrial grade PVC and high temperature CPVC. Encase TM Enpure TM Duraplus TM 1/2" 4" (15mm - 100mm) High-purity polypropylene pipe, valves and fittings with a socket fusion joining system. 1-1/2" 12" (40mm - 300mm) Polypropylene double containment system for corrosive waste drainage consisting of an electrofusion fitting with a heavy-gauge resistance wire molded into the socket. ABS Industrial 3/8" 12" (10mm 300mm) Complete ABS pressure pipe, valves & fitting systems. DOUBLE CONTAINMENT SYSTEMS CustomGuard Carrier: 1/2" 20" (15mm 500mm) Containment: 2" 26" (50mm 660mm) Custom designed and fabricated double containment systems for similar & dissimilar materials. Centra-Guard TM Patented electronic low point leak detection system for above ground and below grade piping systems. Clear-Guard 1/2" 8" (15mm 200mm) Fully pressure rated clear containment PVC system with Guardian s patented Centra-Lok fitting design. PAL-AT Cable Leak Detection A microprocessor based system for continuous leak detection. THERMOPLASTIC VALVES Thermoplastic Valves 1/2" 12" (12mm 300mm) IPEX offers a variety of manual & actuated valves in PVC, CPVC, PP, PVDF and ABS. Duratec Airline 3/8" 1" (9.5mm 25mm) Composite pipe and fittings for conveying compressed air and inert gases. Duraplus TM Airline 1/2" 8" (12mm 200mm) A high-impact, ductile ABS pressurized piping system for conveying compressed air and inert gases. COMPRESSED AIR SPECIALTY PRODUCTS Ventilation Duct 6" 24" (150mm 600mm) Diameter Seamless PVC ventilation duct systems. Well Casings 2" 16" (50mm 400mm) PVC corrosion-resistant, maintenancefree casings for well-drop-pipe and submersible pumps. Grooved PVC Pipe 2" 24" (50mm 600mm) Schedule 40, SDR 26 and SDR 21 factory-grooved PVC pipe.

36 SALES AND CUSTOMER SERVICE Canadian Customers call IPEX Inc. Toll free: (866) About the IPEX Group of Companies As leading suppliers of thermoplastic piping systems, the IPEX Group of Companies provides our customers with some of the world s largest and most comprehensive product lines. All IPEX products are backed by more than 50 years of experience. With state-of-the-art manufacturing facilities and distribution centers across North America, we have established a reputation for product innovation, quality, end-user focus and performance. Markets served by IPEX group products are: Electrical systems Telecommunications and utility piping systems PVC, CPVC, PP, PVCO, ABS, PEX, FR-PVDF & PE pipe and fittings (1/4" to 48") Industrial process piping systems Municipal pressure and gravity piping systems Plumbing and mechanical piping systems PE Electrofusion systems for gas and water Industrial, plumbing and electrical cements Irrigation systems s are manufactured by IPEX Inc. Encase TM, Enfield TM, Floway TM, Labline, Neutrasystem2 TM, Neutratank, and Plenumline TM, are trademarks of IPEX Branding Inc. This literature is published in good faith and is believed to be reliable. However, it does not represent and/or warrant in any manner the information and suggestions contained in this brochure. Data presented is the result of laboratory tests and field experience. A policy of ongoing product improvement is maintained. This may result in modifications of features and/or specifications without notice. CTINAWIP IPEX IND0041C

Industrial Product Catalogue

Industrial Product Catalogue Industrial Catalogue www.ipexinc.com ISSUE DATE: NOVEMBER 2011 Process Piping Systems Double Containment Systems Acid Waste Piping Systems Compressed Air Systems Thermoplastic Valves Specialty s We build

More information

PIPING SYSTEMS FOR METALS AND MINING APPLICATIONS

PIPING SYSTEMS FOR METALS AND MINING APPLICATIONS PIPING SYSTEMS FOR METALS AND MINING APPLICATIONS METALS & MINING APPLICATIONS Process Piping Systems Double Containment Systems Thermoplastic Valves Compressed Air Pressure Piping Systems Rigid PVC Conduit

More information

VINYL PROCESS PIPING SYSTEMS. Complete systems of pipe, valves and fittings designed, manufactured and backed by one company.

VINYL PROCESS PIPING SYSTEMS. Complete systems of pipe, valves and fittings designed, manufactured and backed by one company. I N D U S T R I A L S Y S T E M S VINYL PROCESS PIPING SYSTEMS Complete systems of pipe, valves and fittings designed, manufactured and backed by one company. We build tough products for tough environments

More information

Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification:

Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: Submittal Data Sheet Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: Date Date Date introduction < APPLICATIONS > Plant Air Ventilation Valve Actuation-Control

More information

LABORATORY & DEIONIZED WATER SYSTEMS DESIGN AND CONSTRUCTION STANDARD

LABORATORY & DEIONIZED WATER SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.

More information

IPEX Solvent Cements Catalogue

IPEX Solvent Cements Catalogue IPEX Solvent Cements Catalogue I P E X S O L V E N T C E M E N T S CEMENTS, PRIMERS & APPLICATORS for Industrial, Mechanical, Plumbing and Electrical Piping systems. Choosing the correct SOLVENT CEMENT

More information

introduction Product Data Sheet < STANDARDS >

introduction Product Data Sheet < STANDARDS > < STANDARDS > introduction AWWA C905 NQ 3624-250 CSA CB137.3 NSF 61 IPEX Centurion is PVC pipe used for potable water systems and other pressure pipe applications. IPEX Centurion systems are resistant

More information

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms. PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Installation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING. We Build Tough Products for Tough Environments

Installation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING. We Build Tough Products for Tough Environments Installation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING W A T E R S E R V I C E T U B I N G We Build Tough Products for Tough Environments Blue904 Installation Guide 1 TABLE OF CONTENTS Introduction...................................2

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Submittal for Aquatherm Piping System

Submittal for Aquatherm Piping System Submittal for Aquatherm Piping System Project Name: Project Location: Date: To whom it may concern, We are proposing to upgrade the piping parts on the above project to the polypropylene Aquatherm Green

More information

Bid Opportunity PLUMBING SYSTEMS Section Installation of Boiler Heating Systems Page 1 of 7 Centennial Pool, 90 Sinclair

Bid Opportunity PLUMBING SYSTEMS Section Installation of Boiler Heating Systems Page 1 of 7 Centennial Pool, 90 Sinclair Installation of Boiler Heating Systems Page 1 of 7 SECTION PAGE PART 1 GENERAL 2 1.1 General 2 1.2 Reference 2 1.3 Work Included 2 1.4 Related Work Specified Elsewhere 2 PART 2 PRODUCTS 3 2.1 Pipe and

More information

Water & Industrial Products Catalog

Water & Industrial Products Catalog Water & Industrial Products Catalog www.smith-blair.com info@smith-blair.com Phone: 800..9705 or 870.77.527 After Hours Number: 90.277.998 Fax: 800.8.792 or 870.77.52 EMERGENCY PHONE 90.277.998 In the

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING SECTION 221316 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following soil and waste, sanitary drainage and vent piping inside the building: 1. Pipe, tube,

More information

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY Section Includes: 1. Pipe and fittings. 2. Drain Basin. 3. De-chlorination tablet feeder. 4. Non-pressure transition couplings.

More information

Styrene Free Structural Liner for Sewers and Culverts

Styrene Free Structural Liner for Sewers and Culverts Styrene Free Structural Liner for Sewers and Culverts INTRODUCING NOVAFORM PVC LINER FOR SEWER AND CULVERT REHABILITATION 6 to 30 diameters (150mm to 750mm) Factory-made, quality-controlled and tested

More information

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM DIVISION 22 PLUMBING PART 1 GENERAL 1.01 DESCRIPTION A. Provide a complete system of soil, waste, and vent piping to fixtures and equipment, including traps, floor drains and cleanouts, extending to a

More information

is Central. Gas Water & Waste Water Energy Industrial Your One-Stop Source State-of-the art manufacturing

is Central. Gas Water & Waste Water Energy Industrial Your One-Stop Source State-of-the art manufacturing Experience is Central. Backed by more than 50 years of experience, Georg Fischer Central Plastics is the largest single source supplier for meter connections including products and technologies that prevent

More information

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms. SECTION 22 13 00 FACILITY SANITARY SEWERAGE PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

CHEMICAL WASTE OVERVIEW CONTINUED

CHEMICAL WASTE OVERVIEW CONTINUED CHEMICAL WASTE OVERVIEW CONTINUED Monitoring Systems Many State and local authorities require that the ph level of chemical waste discharged into the sewer is monitored and quite frequently that the results

More information

STATE UNIVERPROGRAM DIRECTIVES

STATE UNIVERPROGRAM DIRECTIVES DIRECTIVE 15H-10 PIPING TYPES AND MATERIALS Issue date: September 2017 Steam & Condensate Piping Service & Location Pipe Size Pipe Material & Weight Joint Type Fitting Material Insulation Material Low

More information

The Strongest, Toughest, Most Flexible Pipe.

The Strongest, Toughest, Most Flexible Pipe. The Strongest, Toughest, Most Flexible Pipe. M U N I C I P A L S Y S T E M S INTRODUCING LARGE DIAMETER BIONAX FOR WATER TRANSMISSION New 14", 16" & 18" (350, 400 & 450 mm) standard CIOD sizes with the

More information

Consistent Durable Cost-Efficient PVC Liner

Consistent Durable Cost-Efficient PVC Liner Consistent Durable Cost-Efficient PVC Liner INTRODUCING NOVAFORM PVC LINER FOR SEWER AND CULVERT REHABILITATION 6 to 30 diameters (150mm to 750mm) Industry-standard DR 35 and DR 41 Factory-made, quality-controlled

More information

PE Electrofusion Tapping Tees for Gas Applications

PE Electrofusion Tapping Tees for Gas Applications PE Electrofusion Tapping Tees for Gas Applications E L E C T R O F U S I O N S Y S T E M S EF S TM ELECTROFUSION TAPPING TEES Corrosion-proof Construction Leak-proof Seals Easy Installation Best after-market

More information

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties: SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Roof flashing

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 4 4.1 GENERAL REQUIREMENTS Joints and Connections 4.1.1 Tightness Joints and connections in the plumbing system shall be gas tight and watertight for the pressure required by test, with the exceptions

More information

SANITARY WASTE AND VENT PIPING

SANITARY WASTE AND VENT PIPING SECTION 15420 - SANITARY WASTE AND VENT PIPING PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

SV24. Submittal Special Precautions Specifications Installation. 12½ (31.8 cm) 12½ (31.8 cm) 12 (30.5 cm) 12 (30.5 cm) 12 (30. Wastewater Sampling Port Technical Data Submittal Special Precautions Specifications Installation 16½" (31.8 (41.9 cm) 8" (20.3 cm) -L -O SUBMITTAL STANDARD: 4" plain end inlet/outlet Highway traffic load

More information

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

D. Encase exterior cleanouts in concrete with access cover installed flush with grade. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS SECTION 02620 PART 1 GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment, and incidentals required to install High Density Polyethylene (HDPE) pressure pipe, fittings, and appurtenances

More information

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780)

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780) 9333 45 Avenue Edmonton, AB Toll Free: 1-800-272-9693 Phone: (780) 436-1930 Fax: (780) 435-4849 info@can-con.com TABLE OF CONTENTS PLASTIC FITTINGS POLYETHYLENE PIPE...- 1 - SERVICE RISERS... - 3 - TRANSITION

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 13 00 _SANITARY SEWER PIPING SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sanitary sewer piping buried 2. Sanitary

More information

Facility Sanitary Sewers

Facility Sanitary Sewers University of New Hampshire University of New Hampshire Scholars' Repository Division 22 Plumbing Chapter 5 Technical Construction and Renovation Standards 4-23-2015 221313 - Facility Sanitary Sewers Sandra

More information

SECTION PLUMBING PIPING SYSTEMS

SECTION PLUMBING PIPING SYSTEMS SECTION 15300 PLUMBING PIPING SYSTEMS PART 1 - GENERAL 1.01 SPECIAL NOTICE A. Each contractor shall read all relevant documents, become familiar with the job, the scope of work, type of general construction,

More information

SECTION (15150) - SANITARY WASTE AND VENT PIPING

SECTION (15150) - SANITARY WASTE AND VENT PIPING SECTION 22 13 16 (15150) - SANITARY WASTE AND VENT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Pipe Materials. 2. Fittings. 3. Joining Materials. B. Related Sections: 1.02 REFERENCES 1.

More information

AWI MANUFACTURING. Quality Products Since USDA Certified. Stainless Steel Floor Drains

AWI MANUFACTURING.  Quality Products Since USDA Certified. Stainless Steel Floor Drains AWI MANUFACTURING Stainless Steel Floor Drains 4 Floor Drains 4 Hub Drains 4 Trench Drains 4 Floor Sinks 4 Cleanouts 4 P-Traps 4 Custom Drains USDA Certified Quality Products Since 1970 www.awimfg.com

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building. SECTION 221413 - FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following storm drainage piping inside the building. 1. Pipe, tube, and fittings. 2. Special pipe

More information

Aerator for Sewer Odor and Corrosion Control

Aerator for Sewer Odor and Corrosion Control Aerator for Sewer Odor and Corrosion Control MUNICIPAL SYSTEMS Sewer Force Main Discharge Sewer Wet Wells & Storage Tanks Irrigation Ponds We build tough products for tough environments A NEW SOLUTION

More information

SECTION PLUMBING PIPING

SECTION PLUMBING PIPING SECTION 22 1000 PLUMBING PIPING PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Perform Work in accordance with authority having jurisdiction standards. Utilize products as indicated in drawings and as allowed

More information

THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE.

THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE. THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE. MUNICIPAL SYSTEMS BIONAX PVCO PRESSURE PIPE FOR WATER AND SEWAGE FORCEMAINS, TRANSMISSION AND DISTRIBUTION LINES 4 through 30 (100 to 750 mm) 165, 235 & 305

More information

Aerator for Sewer Odor and Corrosion Control

Aerator for Sewer Odor and Corrosion Control Aerator for Sewer Odor and Corrosion Control MUNICIPAL SYSTEMS Sewer Force Main Discharge Sewer Wet Wells & Storage Tanks Irrigation Ponds Wastewater Treatment Tanks We build tough products for tough environments

More information

Complete Drainage Systems for Noncombustible Buildings

Complete Drainage Systems for Noncombustible Buildings Complete Drainage Systems for Noncombustible Buildings D W V S Y S T E M S System 15 Pipe & Fittings System XFR Drain-Guard TM Pipe & Fittings Double Containment MJ Grey TM Mechanical Couplings Firestop

More information

Meter Connection Products: Overview

Meter Connection Products: Overview : Overview Georg Fischer Central Plastics entered the meter connection business in 1955 with the design and introduction of the insulated meter swivel and insulated union. We understand the critical nature

More information

GB-20. Submittal Specifications Installation Application Specific Details

GB-20. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 27" (68.6 cm) 4¼" (10.8 cm) 15" (38.1 cm) 10¾" (27.3 cm) SUBMITTAL (53.3 cm) STANDARD: 2" plain end

More information

IPEX Solvent Cements Catalogue

IPEX Solvent Cements Catalogue IPEX Solvent Cements Catalogue I P E X S O L V E N T C E M E N T S CEMENTS, PRIMERS & APPLICATORS for Industrial, Plumbing and Electrical Piping systems. IPEX Solvent Cements Choosing the correct cement

More information

SECTION FACILITY STORM DRAINAGE PIPING

SECTION FACILITY STORM DRAINAGE PIPING SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Daytona Beach Pier Building Renovation Jun 2010

Daytona Beach Pier Building Renovation Jun 2010 SECTION 15150 - SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION POLYETHYLENE PRESSURE PIPE

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION POLYETHYLENE PRESSURE PIPE SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION 33 11 13.24 POLYETHYLENE PRESSURE PIPE PART 1 GENERAL... 2 1.1 Description... 2 1.2 Reference Specification... 2 1.3

More information

SECTION FACILITY STORM DRAINAGE PIPING

SECTION FACILITY STORM DRAINAGE PIPING SECTION 22 1413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE.

THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE. THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE. MUNICIPAL SYSTEMS BIONAX PVCO PRESSURE PIPE FOR WATER AND SEWAGE FORCEMAINS, TRANSMISSION AND DISTRIBUTION LINES 4 through 30 (100 to 750 mm) 165, 235 & 305

More information

GB-75. Submittal Specifications Installation Application Specific Details

GB-75. Submittal Specifications Installation Application Specific Details GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 38½" 51½" (1,308 (978 mm) 13½" 12½" (343 (318 mm) 38" 26" (660 (965 mm) 68" 46" (1,168 (1,727 mm) 33½"

More information

HYDRONIC PIPING CHAPTER 12

HYDRONIC PIPING CHAPTER 12 CHAPTER 12 HYDRONIC PIPING SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern the construction, installation, alteration and repair of hydronic piping systems. This chapter

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES SECTION 15510 HYDRONIC PIPING A. ANSI/ASME SEC 9: Welding and Brazing Qualifications. B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300. C. ANSI/ASME

More information

Installation Guide. System 15 Pipe & Fittings System XFR Pipe & Fittings Drain-Guard TM Double Containment MJ Grey TM Mechanical Couplings

Installation Guide. System 15 Pipe & Fittings System XFR Pipe & Fittings Drain-Guard TM Double Containment MJ Grey TM Mechanical Couplings Installation Guide D W V S Y S T E M S System 15 Pipe & Fittings System XFR Pipe & Fittings Drain-Guard TM Double Containment MJ Grey TM Mechanical Couplings We build tough products for tough environments

More information

GB-75. High Efficiency Grease Interceptor Technical Data. Submittal Specifications Installation Application Specific Details

GB-75. High Efficiency Grease Interceptor Technical Data. Submittal Specifications Installation Application Specific Details High Efficiency Grease Interceptor Technical Data Submittal Specifications Installation Application Specific Details 38½" 38.5" (97.8 cm) 12½" (31.7 cm) 26" (66.0 cm) 46" (116.8 cm) 33½" 32" (851 (81.3

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 14 00 _STORM WATER PIPING SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Storm water piping 2. Roof drains. 3. Area

More information

APPENDIX C TECHNICAL SPECIFICATIONS HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

APPENDIX C TECHNICAL SPECIFICATIONS HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1 GENERAL 1.01 DESCRIPTION: C TECHNICAL SPECIFICATIONS HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS Scope This section specifies high density polyethylene pipe (HDPE) and fittings for water

More information

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm) Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER

CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER CITY OF WARRENVILLE STANDARD SPECIFICATIONS WATER MAIN, SANITARY SEWER AND STORM SEWER WATER MAIN 1. All open cut water main shall be polyvinyl chloride plastic (PVC) pressure pipe per AWWA specification

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 1423 - STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications. SECTION 13 PIPE, TUBE AND PART 1 - GENERAL 1.01 DESCRIPTION A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications. 1.02 QUALITY ASSURANCE

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES SECTION 23 21 13 HYDRONIC PIPING A. ANSI/ASME SEC 9: Welding and Brazing Qualifications B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300 C. ANSI/ASME

More information

STORM DRAINAGE CHAPTER 11

STORM DRAINAGE CHAPTER 11 CHAPTER STORM DRAINAGE SECTION 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage, except in one- and two-family dwellings.

More information

A. Piping materials shall bear label, stamp, or other markings of specified testing agency.

A. Piping materials shall bear label, stamp, or other markings of specified testing agency. SECTION 221316- PART 1- GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe, tube, and fittings. 2. Specialty pipe fittings. 1.2 INFORMATIONAL SUBMITTALS A. Field quality-control reports. 1.3 QUALITY ASSURANCE

More information

Design and Construction Standards SECTION HYDRONIC PIPING

Design and Construction Standards SECTION HYDRONIC PIPING SECTION 15510 HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES A. ANSI/ASME SEC 9: Welding and Brazing Qualifications. B. ANSI/ASME B16.3: Malleable Iron Threaded Fittings Class 150 and 300. C. ANSI/ASME

More information

Terrain HDPE. Product Guide

Terrain HDPE. Product Guide TAGIG1-PT JULY 2009 Terrain HDPE Product Guide Terrain HDPE BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE No. 07/4479 A modern high density polyethylene system with many advantages over cast iron and other

More information

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial DRAINS: BATH,, SHOWER &, S COMMERCIAL SHOWER DRAINS GENERAL PURPOSE DRAINS FIT-FLUSH CLEAN-OUTS BATH WASTES BATH WASTES KITS/PARTS/COMPONENTS BATH DRAIN BODIES/ASSEMBLIES BATH DRAIN KITS/PARTS/COMPONENTS

More information

Dual Containment Piping Systems

Dual Containment Piping Systems Welded Dual Extruded Cemented ISO 9001:2008 CERTIFIED dual containment Dual Containment Piping Systems chemline.com why choose dual containment? Protecting our environment is everyone s responsibility.

More information

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation Gravity Grease Technical Data Submittal Special Precautions Specifications Installation 75" 81" (205.7 (94.0 cm) 19½" 20" (50.8 (49.5 cm) 21½" 20" (50.8 (54.6 cm) 76½" (194.3 cm) 56½" 57" (144.8 (143.5

More information

SECTION HYDRONIC PIPING

SECTION HYDRONIC PIPING PART 1 GENERAL 1.1 REFERENCES SECTION 23 21 13 HYDRONIC PIPING A. ASME BPVC Section IX - Welding and Brazing Qualifications B. ASME B16.3 - Malleable Iron Threaded Fittings Classes 150 and 300 C. ASME

More information

B. This Contractor's work shall include the following specification sections: SECTION MECHANICAL AND ELECTRICAL GENERAL CONDITIONS

B. This Contractor's work shall include the following specification sections: SECTION MECHANICAL AND ELECTRICAL GENERAL CONDITIONS SECTION 22 20 00 - PLUMBING SYSTEMS 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 23 00 00, MECHANICAL AND ELECTRICAL GENERAL CONDITIONS, Section 23 21 00 INSTALLATION OF PIPING,

More information

Fusible PVCTM Pipe for Trenchless Applications

Fusible PVCTM Pipe for Trenchless Applications Fusible PVCTM Pipe for Trenchless Applications M U N I C I P A L S Y S T E M S FUSIBLE PVC TM PIPE FOR HDD AND OTHER TRENCHLESS APPLICATIONS 100mm 900mm (4" 36") CIOD & IPS Sizes 12.2m (40 ft) lengths

More information

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD PART 1: GENERAL 1.01 The design guidelines contained herein include the requirements for drainage and vent systems utilized at The University of Texas at Austin. It is the intention of this document to

More information

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated. SECTION 221316 SANITARY WASTE AND VENT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

More Durable, Resistant and Cost-Effective.

More Durable, Resistant and Cost-Effective. More Durable, Resistant and Cost-Effective. INTRODUCING BIONAX SR WATER PIPE DESIGNED FOR SEISMIC REGIONS Exceeds the Japanese Seismic Design Standard by 70% Compatible with North American Manufactured

More information

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections. SANITARY SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Sanitary Sewer Gravity Mains B. Sanitary Sewer Force Mains C. Sanitary Sewer Services 1.02 DESCRIPTION OF WORK A. Construct sanitary sewer gravity

More information

STORM DRAINAGE CHAPTER 11

STORM DRAINAGE CHAPTER 11 CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,

More information

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems: SECTION 221429 - SUMP PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

HYDRONIC PIPING CHAPTER 12

HYDRONIC PIPING CHAPTER 12 CHAPTER 12 HYDRONIC PIPING SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern the construction, installation, alteration and repair of hydronic piping systems. This chapter

More information

SANITARY DRAINAGE CHAPTER 30

SANITARY DRAINAGE CHAPTER 30 CHAPTER 30 SANITARY DRAINAGE SECTION P3001 GENERAL P3001.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. Plumbing

More information

Stainless Steel Aeration Equipment Specification

Stainless Steel Aeration Equipment Specification Section 15 Stainless Steel Aeration Equipment Specification Part 1 - General 1.01 Description A. Scope of Work 1. Furnish, install and test aeration system including air mains, drop pipes, valves, expansion

More information

GB-50. Submittal Special Precautions Specifications Installation Application Specific Details

GB-50. Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 37" (94.0 cm) 10½" (26.7 (27 cm) 28½" (72.4 cm) (46.7 (45.7 cm) 28" (71.1 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet

More information

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS SECTION 02530 - SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15420 DRAINAGE AND VENT SYSTEMS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All cleanouts above finished (accessible and non-accessible) ceilings shall be extended to the floor above. B. Do

More information

GB-25. Submittal Special Precautions Specifications Installation Application Specific Details

GB-25. Submittal Special Precautions Specifications Installation Application Specific Details Submittal Special Precautions Specifications Installation Application Specific Details 27" (68.6 cm) 4¼" (10.8 cm) 15" (38.1 cm) 10¾" (27.3 cm) SUBMITTAL 21" (53.3 cm) STANDARD: 3" plain end inlet/outlet

More information

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing). SECTION 15421 DRAINS AND CLEANOUTS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. Division 7 - Thermal and Moisture Protection. 2. 15410 - Piping (Plumbing). 1.02 SUBMITTALS A. Product Data: Submit

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties: SECTION 221423 - STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following storm drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Roof drains.

More information

FLOOR DRAINS AWI MANUFACTURING

FLOOR DRAINS AWI MANUFACTURING STAINLESS STEEL FLOOR DRAINS AWI MANUFACTURING TABLE OF CONTENTS Floor Drains...3 Trench Drains...9 Slot Drains... 14 Cleanouts... 15 Floor Sinks... 15 P-Traps... 18 Laterals... 18 Hub Drains... 18 STAINLESS

More information

Grease Management. EnduraGreaseManagement.com. Rethinking Grease Interception

Grease Management. EnduraGreaseManagement.com. Rethinking Grease Interception Grease Management EnduraGreaseManagement.com Rethinking Grease Interception Endura has the right stuff The Right Reason Guided by a philosophy of minimizing downstream toxic waste, Endura engineers have

More information

CONTINUED ON FOLLOWING PAGE

CONTINUED ON FOLLOWING PAGE Date Description of Change Pages / Sections Modified ID 08/05/17 Entire document - mgl PART 1 - INTRODUCTION 1.1 This standard refers to the following plumbing specialties. A. Drains, B. Hydrant and Hose

More information

SceptaCon Trenchless Raceway for Electrical and Telecommunication Cables

SceptaCon Trenchless Raceway for Electrical and Telecommunication Cables ELECTRICAL & TELECOMMUNICATION SYSTEMS SceptaCon Trenchless Raceway for Electrical and Telecommunication Cables 2" - 6" www.kraloyfittings.com THE ELECTRICAL ADVANTAGE THE MISSING LINK IN YOUR PVC SYSTEM

More information

5.0 ENDURA GREASE MANAGEMENT. Endura Grease Interceptors with Spigot format Flow Control Devices.

5.0 ENDURA GREASE MANAGEMENT. Endura Grease Interceptors with Spigot format Flow Control Devices. GREASE MANAGEMENT 5.0 ENDURA GREASE MANAGEMENT New! With Spigot Format Flow Control Devices Diffuser Baffle supplied only with 35/50 GPM models Canplas is pleased to announce the extension of our Endura

More information

A. ASTM F Standard Specification for Pressure-rated Polypropylene (PP) Piping Systems.

A. ASTM F Standard Specification for Pressure-rated Polypropylene (PP) Piping Systems. SECTION 221114 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the water distribution piping system, including potable cold, hot and hot water piping including associated fittings, and specialities

More information

A. This Section includes the following sanitary drainage piping specialties:

A. This Section includes the following sanitary drainage piping specialties: Page 221319-1 SECTION 221319 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information