1 QUAIL TOOLS A PARKER DRILLING COMPANY Operations New Iberia, LA Ph. (337) Victoria, TX Ph. (361) Odessa, TX Ph. (432) Evanston, WY Ph. (37) Texarkana, TX Ph. (93) Williston, ND Ph. (71) Morgantown, WV Ph. (34) Enid, OK Ph. (58) Sales Offices Houston, TX Ph. (281) New Orleans. LA Ph. (54) Denver, CO Ph. (33) Dallas, TX Ph. (972) San Antonio, TX Ph. (21) Pittsburgh, PA Ph. (724) Landing String Specification Sheet 5-7/8'', 34.21#,.625'', Z14, TF-M575 R3 Tube / Pipe Body Tube OD: Inches Tube ID: Inches Nominal Weight: lbs/ft Adjusted Weight (Includes TJs): 4.43 lbs/ft Grade Z14 Tube Wall (nominal):.625 Inches API Class - Tube: 95% RBW.594'' Tube Tensile: 1,362,85 lbs Tube Torsional: 155,68 ft-lbs Tube Collapse: 25,68 psi Tube Internal Yield/Burst: 28,298 psi Displacement Est. (Includes TJs):.147 bbls/ft Capacity Est. (Includes TJs):.198 bbls/ft Type: TF-M575 OD: 7. Inches ID 4. Inches Drift: Inches Maximum MUT : 63,2 ft-lbs Minimum MUT: 52,6 ft-lbs Torsional: 118,5 ft-lbs Torsional: 1,594,3 lbs KL 1/13/16 Providing Quality Rental Tools and Service Since 1978 The following items are registered trademarks of NOV Grant Prideco: HI TORQUE (HT), XT, XT-M, TT, TT-M, TF-M, GT-M, GPDS, SLIP-PROOF, XD15, Z14, V15. The technical information herein is for reference only & should not be construed as a recommendation. The user should consider all field conditions along with other combined factors which may affect the final string design used in the field. Combined loads, slip crushing, elevator hoisting capacity, ID Coatings, and Hardbands are not considered in these figures. Capacity/Displacement and adjusted weight figures are based on pipe purchased at above standard RBW and with longer than standard tool joints. All dimensions are nominal. Figures are subject to change without notice. Please refer to our website for updates:
2 Phone: +1 (281) Drill Pipe Configuration Pipe Body OD Pipe Body Wall Thickness Pipe Body Grade Drill Pipe Length Tool Joint OD Tool Joint ID Pin Tong Box Tong Drill Pipe Performance Maximum MUT Minimum MUT Z-14 Controlled Length TurboFrac-M Performance of Drill Pipe with Pipe Body at 95 % Inspection Class Applied Make-up Torque 63,2 52,6 Maximum Make-up Torque 63,2 Minimum Make-up Torque 52,6 95 % Inspection Class Nominal Weight Designation Drill Pipe Approximate Length (ft) 45. SmoothEdge Height 1/8 Raised Tool Joint SMYS (psi) 135, Upset Type IEU Max Upset OD (DTE) 6. Friction Factor 1. Note: Tong space may include hardfacing. Drill-Pipe Length Controlled Length Best Estimates (without Coating) (with Coating) Nominal (least accurate) Drill Pipe Adjusted Weight (lbs/ft) Operational Max Tension Torque (lbs) Fluid Displacement (gal/ft) Tension Only 1,362,8 Fluid Displacement (Bbls/ft) Combined Loading Fluid Capacity (gal/ft) 51,1 1,287, Fluid Capacity (Bbls/ft) Tension Only 1,325, Drift Size Combined Loading 4,2 1,316,6 Note: Oil field barrel equals 42 US gallons. Note: Drill pipe assembly values are best estimates and may vary due to pipe body mill tolerance, internal plastic coating, and other factors. Performance TurboFrac-M 575 ( 7. OD X 4. ID ) 135, Applied Make-up Tension at Shoulder Tension at Tool Joint Dimensions Tool Joint Torsional Strength Tool Joint Tensile Strength (lbs) Torque Note: To maximize connection operational tensile, a MUT (T4) = 63,3 should be applied. Elevator Shoulder Information 118,5 1,594,3 SmoothEdge Height 1/8 Raised Separation Yield (lbs) (lbs) 1,592, 1,594,3 1,325, 1,594,3 (psi) Balanced OD 7.93 Minimum Tool Joint OD for API Premium Class Minimum Tool Joint OD for Counterbore Internal Gas Pressure Rating (psi) = Envelope External Gas Pressure Rating (psi) = Envelope Elevator OD 1/8 Raised 7.25 Nominal Tool Joint Worn to Bevel Worn to Min TJ OD for OD Diameter API Premium Class , 845,4 828,8 Box OD Elevator Capacity (lbs) 1,31,1 Assumed Elevator Bore Diameter Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 11,1psi. Note: A raised elevator OD increases elevator capacity without affecting make-up torque. Pipe Body Configuration ( OD.625 Wall Z-14 ) Pipe Body Slip Crushing Capacity Pipe Body Performance Slip Crushing Capacity Assumed Slip Length Transverse Load Factor (K) Nominal 95 % Inspection Class API Premium Class (lbs) 95,1 91,1 754, Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from Why Does Drill Pipe Fail in the Slip Area World Oil, 1959 for the slip length and transverse load factor shown and is for reference only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional information. Pipe Body Configuration ( OD.625 Wall Z-14 ) Nominal 95 % Inspection Class API Premium Class Pipe Tensile Strength (lbs) 1,443,2 1,362,8 1,127, Pipe Torsional Strength TJ/PipeBody Torsional Ratio 165, , ,7.93 8% Pipe Torsional Strength Burst 132,1 (psi) 26,64 124,4 28,298 12,2 23,83 Note: Nominal Burst calculated at 87.5% RBW Collapse (psi) 26,618 25,68 22,677 per API. Pipe OD Wall Thickness Nominal Pipe ID Cross Sectional Area of Pipe Body (in^2) Cross Sectional Area of OD (in^2) Cross Sectional Area of ID (in^2) Section Modulus (in^3) Polar Section Modulus (in^3) Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box ID s, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 8% of MUT. NOV GrantPrideco
3 Torque Tension Graph : TurboFrac-M 575 (7. OD X 4. ID) SMYS = 135, (psi) Pipe Body: 95% Inspection Class, OD,.625 wall thickness, Z 14 Pipe Grade (safety factor = 1.) Tension (lbs) 1,8, 1,6, 1,4, 1,2, 1,, 8, Pipe Body in Combined Loading Pipe Body Yield at 95% Inspection Class Premium Pipe Body Yield (8% Inspection Class) Performance (based on MUT) Tool Joint Yield Tool Joint Shoulder Separation TJ Operational Limit (Max MUT) TJ Operational Limit (Min MUT) 6, 4, 2, Torque (ft lbs)
4 Drill Pipe Operational Limits ( at Maximum MUT = 63,2 ) : TurboFrac-M 575 (7. OD X 4. ID) SMYS = 135, (psi) Pipe Body: 95% Inspection Class, OD,.625 wall thickness, Z 14 Pipe Grade 1,6, Overload Zone 1,4, 1,2, Tension (lbs) 1,, 8, 6, Operational limit (safety factor = 1.) 4, 2, Operational Torque (ft lbs)
5 Drill Pipe Operational Limits ( at Minimum MUT = 52,6 ) : TurboFrac-M 575 (7. OD X 4. ID) SMYS = 135, (psi) Pipe Body: 95% Inspection Class, OD,.625 wall thickness, Z 14 Pipe Grade 1,4, Overload Zone 1,2, 1,, Tension (lbs) 8, 6, Operational limit (safety factor = 1.) 4, 2, Operational Torque (ft lbs)
6 Operational Limits of Drill Pipe TurboFrac-M 575 Tool Joint OD 7. Tool Joint ID 4. Tool Joint Specified Minimum 135, Yield Strength (psi) Pipe Body 95 % Inspection Class Pipe Body OD Wall Thickness.625 Pipe Body Grade Z-14 Combined Loading for Drill Pipe at Combined Loading for Drill Pipe at Maximum Make-up Torque = 63,2 Minimum Make-up Torque = 52,6 Operational Torque 2,7 5,4 8,1 1,8 13,4 16,1 18,8 21,5 24,2 26,9 29,6 32,3 34,9 37,6 4,3 43, 45,7 48,4 51,1 Assembly Pipe Body Max Operationa Assembly Pipe Body Max Tension Tension l Torque Max Tension Max Tension Max Tension Max Tension (lbs) (lbs) (lbs) (lbs) (lbs) (lbs) 1,362,8 1,592, 1,325, 1,362,8 1,325, 1,362,6 1,592, 2,1 1,325, 1,362,7 1,325, 1,362, 1,592, 4,2 1,325, 1,362,4 1,325, 1,361, 1,592, 6,3 1,325, 1,361,7 1,325, 1,359,6 1,592, 8,5 1,325, 1,36,8 1,325, 1,357,8 1,592, 1,6 1,325, 1,359,7 1,325, 1,355,5 1,592, 12,7 1,325, 1,358,3 1,325, 1,352,9 1,592, 14,8 1,325, 1,356,7 1,325, 1,349,8 1,592, 16,9 1,325, 1,354,8 1,325, 1,346,2 1,592, 19, 1,325, 1,352,6 1,325, 1,342,3 1,592, 21,2 1,325, 1,35,1 1,325, 1,337,9 1,592, 23,3 1,325, 1,347,5 1,325, 1,333,1 1,592, 25,4 1,325, 1,344,5 1,325, 1,328,1 1,592, 27,5 1,325, 1,341,4 1,325, 1,322,4 1,592, 29,6 1,325, 1,337,9 1,325, 1,316,3 1,592, 31,7 1,325, 1,334,2 1,325, 1,39,7 1,592, 33,8 1,325, 1,33,3 1,325, 1,32,7 1,592, 36, 1,325, 1,325,8 1,325, 1,295,2 1,592, 38,1 1,321,3 1,321,3 1,325, 1,287,3 1,592, 4,2 1,316,6 1,316,6 1,325, 1,362,8 1,362,6 1,362, 1,361, 1,359,6 1,357,8 1,355,5 1,352,9 1,349,8 1,346,2 1,342,3 1,337,9 1,333,1 1,328,1 1,322,4 1,316,3 1,39,7 1,32,7 1,295,2 1,287,3 Operational drilling torque is limited by the Make-up Torque. Make-up Torque Range Operational drilling torque is limited by the Make-up Torque. Min MUT Max MUT Make-up Torque Max Tension 52,6 1,325, 53,8 1,355,2 55, 1,385,4 56,1 1,413,1 57,3 1,443,4 58,5 1,473,6 59,7 1,53,8 6,8 1,531,5 62, 1,561,8 63,2 1,592, (lbs) Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible. Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box ID s, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 8% of MUT. NOV GrantPrideco
7 14, Wear for TurboFrac M 575 (7. OD X 4. ID) Material SMYS (specified minimum yield strength) = 135, (psi) 12, 1, Torque (ft lbs) 8, 6, 4, Torsional Strength Maximum MUT Minimum MUT Pipe Body 8% of Premium Pipe Body Torsional Strength Pipe Body: OD,.625 wall thickness, Z 14 Pipe Grade 2, Tool Joint OD
8 Wear Table TurboFrac-M 575 Tool Joint OD Tool Joint Specified Minimum Tool Joint ID 135, Yield Strength (psi) Wear New OD Worn OD Tool Max Max Min MUT Max Tension Joint OD Torsional Tension MUT Strength (lbs) (lbs) 7 118,5 63,1 1,591,4 52,6 1,325, ,1 62,4 1,577,5 52, 1,313, ,8 61,7 1,563,7 51,5 1,34, ,4 61, 1,549,9 5,9 1,292, ,1 6,3 1,536,1 5,3 1,281, ,8 59,6 1,522,4 49,7 1,269, ,4 58,9 1,58,7 49,1 1,257, ,1 58,1 1,495, 48,5 1,245, ,8 57,4 1,481,3 47,9 1,234, ,5 56,7 1,467,6 47,3 1,222, ,2 56,1 1,454, 46,8 1,212, ,9 55,3 1,44, 46,2 1,21,1 Pipe Body Combined Loading Table (Torque-Tension) Pipe Body 95 % Inspection Class Pipe Body OD Wall Thickness.625 Pipe Body Grade Z-14 Pipe Body Torque Pipe Body Max Tension (lbs) 1,362,8 14,1 1,357,2 28,3 1,34,1 42,4 1,311,2 56,6 1,269,4 7,7 1,213,9 84,8 1,142,4 99, 1,51, 113,1 935,4 127,2 784,1 141,4 567,3 155,5 18,3 Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box ID s, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 8% of MUT. NOV GrantPrideco
Drill Pipe Combined Torsion-Tension To Yield Pipe Tubes
Drill Pipe Combined Torsion-Tension To Yield Pipe Tubes The charts that follow indicate the minimum torsional yield strength of the pipe body tube under tension. Locate the appropriate figure for the pipe
More informationOptional Drill Pipe Products
Drill Pipe At RDT we understand our customer s need for durability and performance when choosing the drill pipe that they will use. Each joint of pipe we produce goes through our intense quality assurance
More informationUSS-LIBERTY TC. Proprietary TightFit TM. Thread Casing Connection
USS-LIBERTY TC Proprietary TightFit TM Thread Casing Connection USS-LIBERTY TC Proprietary TightFit TM Thread Casing Connection Hooked TightFit TM thread form Unique metal-to-metal seal Robust internal
More informationAPI 5DP DRILL PIPE & API 7-1 HW DRILL PIPE
API DP DRILL PIPE & API -1 HW DRILL PIPE In 18, our journey into the business of repairing valves and industrial instrumentation began. That journey has led us to represent and service well known American
More informationExceptional Strength Properties
PREMIUM UPSET TUBING With a continued focus on customer satisfaction through innovative products and services, RDT Inc. is proud to announce the introduction of our newest product line, Premium Upset Tubing.
More informationSTAR Downhole Tubing (Aliphatic Amine Cured Epoxy - Product Data)
STAR Downhole Tubing (Aliphatic Amine Cured Epoxy - Product Data) Product Description Pressure - Up to 4000 psi (27,6 MPa) Resin System - Aliphatic Amine Cured Epoxy Reinforcement - Premium Fiberglass
More informationIntroduction. High Performance, Streamline Connections for 4 in. Drill Pipe
Advanced Drill Pipe With Streamline Connections Enhances Slim-hole Drilling Performance Michael J. Jellison, Grant Prideco; Guillaume Plessis, Grant Prideco; Andre Glowacz, Total; John M. Pasnak, Saudi
More informationSTAR Downhole Casing (Aliphatic Amine Cured Epoxy - Product Data)
STAR Downhole Casing (Aliphatic Amine Cured Epoxy - Product Data) Product Description Pressure - Up to 4000 psi (27,6 MPa) Resin System - Aliphatic Amine Cured Epoxy Reinforcement - Premium Fiberglass
More informationFiberglass Epoxy GRE Integral Joint Tubing
Fiberglass Epoxy GRE Applications Production Wells Injection Wells Saltwater Disposal Wells Chemical Disposal Wells Water Source Wells Solution Mining Riser Mains Centron tubing is precision wound on state-of-the-art
More informationLanding String. Superior weld-free design for safe and easy running
Landg Strg Superior weld-free design for safe and easy runng Ultra Deepwater Trends Drive Technology Farther Operators are pioneerg deep-offshore exploration and development projects water depths up to
More informationOil Country Tubular Ltd. INDIA. ISO 9001 : 2015 Company
Oil Country Tubular Ltd. INDIA ISO 9001 : 2015 Company m Oil Country Tubular Ltd. ISO 9001 :2015 Company Manufacturer/ Processor of Oil Country Tubular Goods Drill Pipes/ Heavy Weight Drill Pipes/ Drill
More informationDeepwater Landing String Design
AADE 01-NC-HO-05 Deepwater Landing String Design By: Richard J. Adams T.H. Hill Associates Inc., Sean E. Ellis T.H. Hill Associates Inc., Thomas M. Wadsworth T.H. Hill Associates Inc., Gary W. Lee Jr.
More informationINTRODUCTION. Research and Development activities are continuous phenomena at OCTL aimed at upgradation of technology and manufacturing processes.
INTRODUCTION Oil Country Tubular Limited (OCTL), is one of the leading companies in the World processing a wide range of Oil Country Tubular Goods required for the Oil Drilling and Exploration Industry.
More informationSTAR Downhole Tubing/Casing (Anhydride Cured Epoxy - Product Data)
STAR Downhole Tubing/Casing (Anhydride Cured Epoxy - Product Data) Product Description Pressure - Up to 2500 psi (17,2 MPa) Resin System - Anhydride Cured Epoxy Reinforcement - Premium Fiberglass Joining
More informationTechnology that works for you.
Technology that works for you. WATER WELL & MINERAL EXPLORATION Drilling accessories designed for use in Water Well and Mineral Exploration are illustrated in this brochure and are manufactured to the
More informationPERFORATOR Oil and Gasfield Drill Pipes
PERFORATOR Oil and Gasfield Drill Pipes API approved Upsetted pipe in grade E, X, G + S Tool joint material acc. API 5DP Dimensions up to 5 1/2 pipe Hard banding acc. to ARNCO 100 XT, 150 XT, 300 XT Tuboscope
More informationDRILL YOUR WELL WITH QUAIL RELEASED
DRILL YOUR WELL WITH QUAIL RELEASED 2017 www.quailtools.com CONTENT Welcome 4 4 Company Story Story 5 5 Dedicated 6 6 Engineering 7 7 Quality 8 8 HSE HSE 9 9 Rental Tools Tools 10 10 Customer Service 11
More informationPH6 / PH4 / CS Connections
IDM Code GDL23376/0 / November 2016 41. TenarisHydril PH6 / PH4 / CS Connections Scope These guidelines apply specifically to the use of TenarisHydril PH6 / PH4 / CS connections. This document should be
More informationConcept of Drill Pipe development for UDD (Ultra Deep Drilling)
Concept of Drill Pipe development for UDD (Ultra Deep Drilling) 5 September 2008 Contents Understanding of UDD s problem deep water problem Requirements to Drill Pipe General requirements Opinions in papers
More informationWho we are. API Facility: Spec 5DP Spec 5CT Spec 7-1 Q1 Spec
Who we are Established in 2006 to supply API drilling tubular tools Over 150 years of experience in tubular manufacturing Co-founders of two different Tubular Manufacturing Companies API Facility: Spec
More informationLEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code
LEGACY REPORT ER-5608* Reissued February 1, 2004 www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional Office 900 Montclair Road, Suite A, Birmingham,
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 10407-2 First edition 2008-10-15 Petroleum and natural gas industries Rotary drilling equipment Part 2: Inspection and classification of used drill stem elements Industries du
More informationGREEN THREAD Piping Systems
Bulletin No. A1300 February 15, 2006 SMITH FIBERCAST GREEN THREAD Piping Systems PRODUCT GREEN THREAD pipe is filament wound using an amine cured epoxy resin and fiberglass and has a resin-rich liner reinforced
More informationHIGH STRENGTH, HIGH TOUGHNESS DRILL STEM PRODUCTS
HIGH STRENGTH, HIGH TOUGHNESS DRILL STEM PRODUCTS Proprietary Material Grades HW-95, HW-105, S-135T, Z-140, V-150 and UD-165 Drilling Deeper? High High s strength trength d drill rill p pipe ipe e enables
More informationControl Lines & Flatpacks Control Line
CONTROL LINE MANUFACTURING This range includes control lines (hydraulic tubing) designed for use in harsh environments such as those created by chemical injection or well monitoring and other applications
More informationNORRIS. Drive Rods. Engineered performance. Designed tough.
NORRIS Drive Rods Engineered performance. Designed tough. 1 (25,4 mm) Norris Drive Rods with 7/8 (22,23 mm) fullsize couplings Tubing size Improvement 27/8 (73,0 mm) 37% improvement in flow area when compared
More informationSPE DISTINGUISHED LECTURER SERIES is funded principally SPE FOUNDATION
SPE DISTINGUISHED LECTURER SERIES is funded principally through a grant of the SPE FOUNDATION The Society gratefully acknowledges those companies that support the program by allowing their professionals
More informationDIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3788 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 04 00
More information(IN ACCORDANCE WITH ISO 10474/EN10204/DIN50049 "type 3.1") SHIPPERS NO. VEHICLE I.D SPECIFICATION AND GRADE O.D.: WALL: MIN: MAX:
UNITED STATES STEEL TUBULAR S TIME: 09:22:14 CERTIFIED REPORT SHIPPERS NO. VEHICLE I.D SPECIFICATION AND GRADE PIPE CARBON SMLS STD PIPE API 5L-*44TH ED DTD OCT 2007 AND ISO 3183:2007 MOD PSL-2 GRADE B
More informationLanding & Drill String CATALOG
Landing & Drill String CATALOG With international advanced technology, sophisticated equipment and excellent management, Enerserva manufacturing facility of landing string and drill string provides high
More informationCentricast CL-1520 Pipe Product Data
Centricast CL-1520 Pipe Product Data Product Name 14/15 CHEMICAL INDUSTRIAL Applications Acids Salts Oxidizing Agents Chloride Water Materials and Construction All pipe is manufactured with glass fabrics
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 10407-2 First edition 2008-10-15 Petroleum and natural gas industries Rotary drilling equipment Part 2: Inspection and classification of used drill stem elements Industries du
More informationTest Summary Resonant Fatigue Testing 7 OD, ppf, P-110 GB CD
Page 1 of 5 Introduction This report summarizes a Resonant Fatigue Test performed on 7 OD, 26.00 ppf, P-110 Casing finished with GB CD (Casing Drilling) Connections. The test was performed to determine
More informationMACKERAL OIL TOOLS PVT. LTD. PRODUCT CATALOGUE RIGID CENTRALIZERS & STOP RING CATALOGUE
Mackeral centralizer designed to withstand the most extreme down hole conditions. Manufactured form mechanical stock tubing, the centralizer designed to perform in wells containing tight clearances and
More informationCeram Core Product Data
Ceram Core Product Data Product Name 14/15 CHEMICAL & INDUSTRIAL Applications Bottom Ash Wet Fly Ash Vanadium Ore Slurries Potash Tailings Zinc Tailings Taconite Tailings Heavy Salt Slurries Uranium Ore
More information(IN ACCORDANCE WITH ISO 10474/EN10204/DIN50049 "type 3.1") SHIPPERS NO. VEHICLE I.D SPECIFICATION AND GRADE O.D.: WALL: MIN: MAX:
UNITED STATES STEEL TUBULAR S TIME: 09:07:07 CERTIFIED REPORT VEHICLE I.D SPECIFICATION AND GRADE PIPE CARBON SMLS STD PIPE API 5L-*44TH ED DTD OCT 2007 AND ISO 3183:2007 MOD PSL-2 GRADE B AND GRADE X42
More informationCERAM CORE Abrasion Resistant Piping for Power Generation Applications
Manual No. A1700 July 1, 2005 SMITH FIBERCAST CERAM CORE Abrasion Resistant Piping for Power Generation Applications Long Lasting Abrasion Resistant Lightweight CERAM CORE Pipe Outlasts carbon steel, cast
More informationTuboscope Coevorden One-Stop Full-Service Facility for all your Oilfield Tubular Needs
Tuboscope Coevorden One-Stop Full-Service Facility for all your Oilfield Tubular Needs 75 For more than years, NOV Tuboscope has continued to raise the global standard with a comprehensive and integrated
More informationKTM Fire-safe and Anti-Static ASME 150/300 one piece, end entry, flanged ball valve for oil, gas, petrochemical and chemical industries
TM Fire-safe and Anti-Static ASME 150/300 one piece, end entry, flanged ball valve for oil, gas, petrochemical and chemical industries Features eneral applications Ideally suited for use in the oil and
More informationPETOL Big D Tubing Elevator BDA100. Data Book. Warning
PETOL Big D Tubing Elevator BDA100 Data Book Warning Improper use of tubing elevators may result in injury or death. Do Not Exceed Rated Load of 100 Tons. Follow safe practices listed in Data Book. GEARENCH
More informationBlue Riser Connection
TenarisHydril Blue Riser Connection Scope These guidelines apply specifically to the use of TenarisHydril Blue Riser connections. This document should be used in conjunction with the TenarisHydril Running
More informationEVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)
ICBO Evaluation Service, Inc. 5360 WORKMAN MILL ROAD WHITTIER, CALIFORNIA 90601-2299 A subsidiary corporation of the International Conference of Building Officials EVALUATION REPORT Copyright 2001 ICBO
More informationan L.B. Foster Company INSPECTION OILFIELD SERVICES (IOS) CATALOG
an L.B. Foster Company INSPECTION OILFIELD SERVICES (IOS) CATALOG 2 0 1 9 IOS uses its TITAN Tablet to log critical inspection results from any location simplifying paperwork and increasing data integrity.
More informationDIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1163 Reissued 12/2016 This report is subject to renewal 12/2017. DIVISION: 03 00
More informationPrecision Close Tolerance Wear Guides
MACROTECH POLYSEAL, INC. Service, Solutions, Performance Precision Close Tolerance Wear Guides WGT-1000 REV #10003 Manufacturing Capacity Macrotech Polyseal produces high precision Wear Guides in high
More informationMethod For Calculating An Estimated Weight-Per-Foot of Solid-Wall Plastic Pipe
Method For Calculating An Estimated Weight-Per-Foot of Solid-Wall Plastic Pipe 2007 Foreword METHOD FOR CALCULATING AN ESTIMATED WEIGHT-PER-FOOT OF SOLID-WALL PLASTIC PIPE This report was developed and
More informationCoiled Tubing for Downhole Applications
Coiled Tubing for Downhole Applications Tenaris Tubular technologies. Innovative services. Tenaris is the leading global manufacturer and supplier of tubular products and services used in the drilling,
More informationC900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling
1 1 CertainTeed C900/RJ PVC Pipe with CertainTeed s proven Certa-Lok restrained joint system Directional Drilling Underground Water Mains and Restrained, Non-Metallic Change-of-Direction Fittings (No Thrust
More informationDIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GEOTECH ENTERPRISES, INC.
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3623 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 31 00 00 EARTHWORK
More informationGRAPHITE TOWER INTERNALS
GRAPHITE TOWER INTERNALS PERFORMANCE ENGINEERING CONSTRUCTION Engineering tomorrow s corrosion solutions today SOLUTIONS Koch Knight, LLC is the single source for the most demanding corrosion solutions.
More informationDynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.
Design Guide Dynaform Fiberglass Structural Shapes Corrosion Resistant Fire Retardant Low Maintenance Light Weight Long Service Life High Performance Composite Solutions Coupon Properties - Structural
More informationSTAINLESS STEEL SHEETS
STAINLESS & NICKEL ALLOY CHATHAM STEEL CORPORATION 59 STAINLESS STEEL SHEETS TYPE 04, 04L, 6, 6L No. 2B Finish Cold Rolled, Annealed *No. 2D Finish No. Finish Polished One Side No. 4 Finish Polished One
More informationNew Technologies for BOP Shearing
New Technologies for BOP Shearing 09 October 2013 Covey Hall Global Manager for Consulting Services Lloyd s Register Energy Drilling Agenda Motivation for the study GTC Shear Study Ongoing project Future
More informationContents. dimensions and weights external loads deflection and testing installation...17
GRAVITY SEWER Contents 01 02 03 04 05 06 07 08 09 product description...2 short form specification...5 dimensions and weights....................... 6 flow/discharge charts....................... 8 external
More informationI ndependent D rilling E ngineering A xel S perber
I ndependent D rilling E ngineering A xel S perber Ing.-Büro Axel Sperber Eddesser Straße 1 D-31234 Edemissen Drilling Consulting & -Engineering Supervision Project Management most important factor for
More informationTrusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation
0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3105 Reissued 08/2017 Revised 10/2018 This report is subject to renewal 08/2019.
More informationNATIONAL CORRUGATED STEEL PIPE ASSOCIATION
NATIONAL CORRUGATED STEEL PIPE ASSOCIATION Designdatasheet No. 18 ISSUED: June 1995 UPDATED: September 1999 This Data Sheet is for general use only and should not be used without first securing competent
More informationDIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: LNA SOLUTIONS A KEE SAFETY LOGISTIC LTD
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3217 Reissued 04/2017 This report is subject to renewal 04/2019. DIVISION: 05 00
More informationHOTVAR. Hot work tool steel
Hot work tool steel General HOTVAR is a high performance molybdenumvanadium alloyed hot-work tool steel which is characterized by: High hot wear resistance Very good high temperature properties High resistance
More informationSECTION STRUCTURAL METAL FRAMING
SECTION 05100 STRUCTURAL METAL FRAMING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Structural steel framing including lintels, shelf angles, bearing plates, anchor bolts and other items as shown on
More informationDIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HELICAL ANCHORS, INC BOONE AVENUE, NORTH MINNEAPOLIS, MINNESOTA 55428
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3982 Reissued 09/2017 This report is subject to renewal 09/2019. DIVISION: 31 00
More informationCOPYRIGHT. Sand Control Fundamentals. Virtual Instructor Led Session #2
Sand Control Fundamentals Non-Gravel Pack Applications Virtual Instructor Led Session #2 Open Hole with Slotted Liner Open Hole with Screen or Prepacked Screen Slotted liners and screens in a non-gravel
More informationHigh Strength Monobore Assemblies With Expanded D:t=12
High Strength Monobore Assemblies With Expanded D:t=12 For The Drilling Engineering Association, November 13, 2013 Elastic Expansion Technology-DEA Background Elastically biased tubular expansion concept
More informationCompatibility Testing of Postle Duraband NC over Arnco 100XT TM
Postle Industries, Inc. Cleveland, OH Compatibility Testing of Postle Duraband NC over Arnco 100XT TM THHA E4-19994 July 31, 2014 Srinivasa R. Koneti, BSME & MSMSE Materials Engineering Manager Disclaimer
More informationDIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: CANTSINK MANUFACTURING, INC. 71 FIRST AVENUE LILBURN, GEORGIA 30047
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1559 Reissued 12/2016 This report is subject to renewal 12/2018. DIVISION: 31 00
More informationHOTVAR Hot work tool steel
T OOL STEEL FACTS HOTVAR Hot work tool steel Wherever tools are made Wherever tools are used General HOTVAR is a high performance molybdenumvanadium alloyed hot-work tool steel which is characterized by:
More informationDynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.
Design Guide Dynaform Fiberglass Structural Shapes Corrosion Resistant Fire Retardant Low Maintenance Light Weight Long Service Life High Performance Composite Solutions Pultrusion Process Pultrusion is
More informationBulletin No. A1380 September 15, Smith Fibercast CENTRICAST PLUS RB-2530 Piping Systems
Bulletin No. A1380 September 15, 2005 Smith Fibercast CENTRICAST PLUS RB-2530 Piping Systems PRODUCT CENTRICAST PLUS RB-2530 pipe is manufactured with high strength glass fabrics and our highly resilient
More informationDIVISION: EXTERIOR IMPROVEMENTS SECTION: RETAINING WALLS SECTION: SEGMENTAL RETAINING WALLS REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1784 Issued 02/2018 This report is subject to renewal 02/2019. DIVISION: 32 00 00
More informationDRISCOPLEX 6500 MDPE PIPE and FITTINGS DATA SHEET
PerformancePipe.com DRISCOPLEX 6500 MDPE PIPE and FITTINGS DATA SHEET DriscoPlex 6500 Pipe and Fittings meet or exceed: ASTM D2513, D2683, D3261 CAN/CSA-B137.4 UPC ASTM D3350, cell classification PE234373E
More informationREPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3145 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 05 00 00 METALS SECTION:
More informationDIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: MAGNUM PIERING, INC. 156 CIRCLE FREEWAY DRIVE CINCINNATI, OHIO 45246
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2997 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 31 00
More informationISO INTERNATIONAL STANDARD. Petroleum and natural gas industries Procedures for testing casing and tubing connections
INTERNATIONAL STANDARD ISO 13679 First edition 2002-12-15 Petroleum and natural gas industries Procedures for testing casing and tubing connections Industries du pétrole et du gaz naturel Procédures de
More informationC900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling
1 CertainTeed C900/RJ PVC Pipe with CertainTeed s proven Certa-Lok restrained joint system Directional Drilling Underground Water Mains and Restrained, Non-Metallic Change-of-Direction Fittings (No Thrust
More informationTHERMOFIT AP2000 TUBING HEAT-SHRINKABLE CROSSLINKED MODIFIED POLYOLEFIN, ADHESIVE LINER
Product Brand:Raychem 305 Constitution Drive, Menlo Park, CA 94025 SPECIFICATION: RW-1001 THIS ISSUE: ISSUE 3 DATE: April 11, 2003 REPLACES: ISSUE 2 THERMOFIT AP2000 TUBING HEAT-SHRINKABLE CROSSLINKED
More informationINCOLOY alloy 803. Publication Number SMC-033 Copyright Special Metals Corporation, 2004 (Sept 04)
INCOLOY alloy 83 (UNS S3545), an iron-nickelchromium alloy, is designed for use in petrochemical, chemical and thermal processing applications. The nickel and chromium contents of alloy 83 are higher than
More informationHow to Design a Singly Reinforced Concrete Beam
Time Required: 45 minutes Materials: -Engineering Paper -Calculator -Pencil -Straight Edge Design For Flexural Limit State How to Design a Singly Reinforced Concrete Beam Goal: ΦMn > Mu Strength Reduction
More informationI. Selection Procedure for DOUBLE PLUS, Outboard Roller and Top Roller Chain
I. Selection Procedure for DOUBLE PLUS, Outboard Roller and Top Roller 1) Confirmation of operating conditions for free flow conveyor The following information is needed in order to select an appropriate
More informationPITTWRAP CF JACKETING Product Datasheet
PITTWRAP CF JACKETING Product Datasheet 1. Description and Area of Application PITTWRAP CF jacketing is a cellulose free fiberglass reinforced vapor retarder insulation jacketing, used for protecting above
More informationPMG LISTING CRITERIA FOR MULTILAYER PIPE AND FITTINGS ASSEMBLY FOR REFRIGERANT APPLICATIONS LC1036
www.icc-es-pmg.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council PMG LISTING CRITERIA FOR MULTILAYER PIPE AND FITTINGS ASSEMBLY FOR REFRIGERANT APPLICATIONS LC1036 August
More informationDenlok Performance Advantages
Jacking Strength (tons) 0.08 0.04 0.15 0.25 0.20 0.40 Inches 2.00 3.04 Denlok Performance Advantages Municipal Advantages Minimum 100 year life guarantee Demonstrated results from centuries of vitrified
More informationASSESSING THE EFFECTS OF CORROSION ON THE MECHANICAL INTEGRITY OF A PIPELINE SUSPENSION BRIDGE
ASSESSING THE EFFECTS OF CORROSION ON THE MECHANICAL INTEGRITY OF A PIPELINE SUSPENSION BRIDGE Chris Alexander Stress Engineering Services, Inc. Houston, Texas Henry Cartaya, P.E. Energistix, Inc. The
More informationResource Guide. Section 4: Ni-Resist
Resource Guide Section 4: Ni-Resist Section 4 Ni-Resist Description of Grades... 4-3 201 (Type 1) Ni-Resist... 4-4 202 (Type 2) Ni-Resist... 4-6 Stock Listings... 4-8 4-2 Ni-Resist Description of Grades
More informationDevelopment of ultra-high strength seamless pipes for Perforating Guns. G. Gomez, S. Cravero, M. Bellingardi
Development of ultra-high strength seamless G. Gomez, S. Cravero, M. Bellingardi INTRODUCTION Pipe for Perforating Gun Carriers (PG) need to sustain during field operation high external hydrostatic pressures
More informationACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE
www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT AC237 Approved June 2009
More informationModelling thickness limits transition joints between pipes of different thickness
Institute of Materials Engineering TITLE: Modelling thickness limits transition joints between pipes of different thickness AUTHOR: Michael Law DATE OF REPORT: November 2008 APPROVED BY: W Payten ISSUED
More informationresearch report Estimating the Response of Cold-Formed Steel Frame Shear Walls RESEARCH REPORT RP REVISION 2006
research report Estimating the Response of Cold-Formed Steel Frame Shear Walls RESEARCH REPORT RP03-7 2003 REVISION 2006 American Iron and Steel Institute Estimating the Response of Cold-Formed Steel Frame
More informationDIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: LINDAPTER
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3330 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 05 00 00 METALS SECTION:
More informationMetal-plate connections loaded in combined bending and tension
Metal-plate connections loaded in combined bending and tension Ronald W. Wolfe Abstract This study evaluates the load capacity of metal-plate connections under combined bending and axial loads and shows
More information8 Design Specification
This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated
More informationPIPENG.COM : DNV OS F101 Submarine Pipelines : Section 5 D 200 Pipeline Wall Thickness
PIPENG.COM : DNV OS F101 Submarine Pipelines : Section 5 D 200 Pipeline Wall Thickness This example should be used with the Pipeng calculators : http://pipeng.com/index.php/ts/itdmotdiam009a : Pipeng DNV
More informationEngineered Gasketing Products
Engineered Gasketing Products Gasketing Products Engineering Data C-1 Notes: C-2 706 5500 5507 Color Binder Temperature Pressure, P x T, max Sealability ASTM Fuel A Nitrogen Creep Relaxation Compressibility
More information4/12/2011. Outline. Introduction. Introduction. Introduction. Introduction
Evaluation of the Orientation of 9 and 18 Reinforcing Bar Hooks in Wide Members By: Nichole Podhorsky, M.S. Student Lesley Sneed, Ph.D., P.E., Missouri S&T Outline I. Introduction II. Objective III. 1.
More informationUses and Applications. Performance
Bondstrand Series 3200 Fiberglass Pipe Class 200 Fire Protection and General Industrial Service (For 2-6 inch diameters, use Series 3000 pipe and Fittings) Uses and Applications Boiler feed water Brine
More informationREPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2328 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 03 00
More informationENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS January 24, 2014 06600-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS
More informationLegacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.
LEGACY REPORT ER-2895 Reissued March 1, 2004 www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional Office 900 Montclair Road, Suite A, Birmingham,
More informationan L.B. Foster Company INSPECTION OILFIELD SERVICES (IOS) CATALOG
an L.B. Foster Company INSPECTION OILFIELD SERVICES (IOS) CATALOG 2 0 1 8 IOS uses its TITAN Tablet to log critical inspection results from any location simplifying paperwork and increasing data integrity.
More informationBettis G-Series Spring-Return Pneumatic Valve Actuator Component Material List. Material List ML.GP Rev. 0 October 2017
Bettis G-Series Spring-Return Pneumatic Valve Actuator Component Material List Material List ML.GP.01.01 Rev. 0 October 2017 Material List ML.GP.01.01 Rev. 0 Table of Contents October 2017 Table of Contents
More informationDate of Issue: August 2017 Affected Publication: API Specification 16A, Specification for Drill-through Equipment, Fourth Edition, April 2017
Date of Issue: August 2017 Affected Publication: API Specification 16A, Specification for Drill-through Equipment, Fourth Edition, April 2017 Errata 1 Section 4.3.4.2, Table 8: The left-most cell in the