Pins Insulator. Composite/Polymers Insulators
|
|
- Joshua Hill
- 6 years ago
- Views:
Transcription
1 Composite/Polymers Insulators Electric network in India operates under very harsh environments. Industrial pollution, marshy land, hilly and unfriendly terrain, extreme weather, coastal region etc. make insulator contamination flashovers the main concern to the electric utility. Variety of solutions were tried to combat the insulator pollution flashover. Initially ceramic insulators were in use and then the glass insulators were put to use, but these did not serve the flashover issue. The introduction of Composite Insulators(Polymer Insulators) OR Silicone Insulators was a turning point in the 1970s. These silicone rubber insulators / composite insulators were popular for their pollution resistance and were useful ever in sever / harsh weather conditions. The composite insulators have distinctively hydrophobic surface and are resistant to chemical influence, weathering, UV radiation. The physiochemical and mechanical properties of these rubber composite insulators remain constant over wide temperature range. Hence there are negligible changes in the properties of polymer insulation and no electrical or mechanical failures are experienced. Composite insulators we offer can be custom specified, manufactured, tested and are reliable for their service life. They are ideal for use in HVAC, HVDC and in most HV application. Pins Insulator We offer an deal in wide range of Pin Insulators Post Insulator We offer an deal in wide range of Post Insulators
2 Disc Insulators (T&C) We offer an deal in wide range of Disc Insulators (T&C) Composite/polymer insulator We offer an deal in wide range of Disc Insulators (B&S) Lighting Arrestor We offer an deal in wide range of Lighting Arrestor
3 LT Insulator We manufacture and supply high performance L.T. Insulators that are designed semi vitreous body and are used for their capacity to withstand normal domestic voltage up to 440 volts. High in performance and functionality, LT Insulators are widely used in telephone and power supply to houses and other electric applications such as electric iron, toasters, stabilizers, transmission and distribution of power line at low voltage volts in the telephone and telegraphic lines. The different products available in this category include Porcelain low tension shackle insulators, porcelain low tension insulators pin type, porcelain guy strain insulators. Porcelain Low Tension Shackle Insulators : Standard Particulars Drawing No Reeco-D-1102 B 45 Reeco LV- S75x90 Reeco LV- S100x115 Type -- IS Type 1 IS Type 2 Leakage Distance mm Wet KV Dry KV KV 1.3 x Actual Dry F.O.V. 1.3 x Actual Dry F.O.V. 1.3 x Actual Dry F.O.V. 1.3 x Actual Dry F.O.V. Mechanical Strength, Transverse Strength KN Net Weight (approx.) Kg Specification: IS:1445, BS:137
4 Disc Insulator T&C We offer an deal in wide range of Disc Insulator T&C Pin Insulator We offer an deal in wide range of Pin Insulator Glass Insulator Pin Insulator We offer an deal in wide range of Pin Insulatorsss
5 Post Insulators We offer an deal in wide range of Post Insulators Disc Insulator We offer an deal in wide range of Disc Insulators (T&C) Disc Insulators We offer an deal in wide range of Disc Insulators (B&S) Solid Core Insulator We offer an deal in wide range of Solid Core Insulator
6 Composite Insulators Electric network in India operates under very harsh environments. Industrial pollution, marshy land, hilly and unfriendly terrain, extreme weather, coastal region etc. make insulator contamination flashovers the main concern to the electric utility. Variety of solutions were tried to combat the insulator pollution flashover. Initially ceramic insulators were in use and then the glass insulators were put to use, but these did not serve the flashover issue. The introduction of Composite Insulators(Polymer Insulators) OR Silicone Insulators was a turning point in the 1970s. These silicone rubber insulators / composite insulators were popular for their pollution resistance and were useful ever in sever / harsh weather conditions. The composite insulators have distinctively hydrophobic surface and are resistant to chemical influence, weathering, UV radiation. The physiochemical and mechanical properties of these rubber composite insulators remain constant over wide temperature range. Hence there are negligible changes in the properties of polymer insulation and no electrical or mechanical failures are experienced. Composite insulators we offer can be custom specified, manufactured, tested and are reliable for their service life. They are ideal for use in HVAC, HVDC and in most HV application. NOMINAL SYSTEM VOLTAGE KV SHED DIA MM MINI. MECHANICA L FAILING LOAD KN DRY ARCING DISTNACE MM MIN. CREEPAGE DISTANCE MM WET POWER FREQUENCY VOLTAGE DRY LIGHTING WITHSTAND VOLTAGE KV TEST KV /
Composite Insulator Components
Composite Insulator Components Composite insulator components A composite insulator is made of at least two insulating parts a core and housing. It is equipped with end fittings. Core. The core is the
More informationEffect of UV-Rays and Salt Contamination on 33kV Silicon Composite Insulators
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 11, Issue 6 Ver. II (Nov. Dec. 2016), PP 45-55 www.iosrjournals.org Effect of UV-Rays and
More informationDevelopment of Composite Line Spacers for Distribution Lines
Development of Composite Line Spacers for Distribution Lines Ichiro Sumitani / Toshiko Kurosawa TOKYO ELECTRIC POWER COMPANY 4-1 Egasaki-Cho, Tsurumi-Ku, Yokohama, 230-8510JAPAN Tel : +81 45 585 8561 Fax
More informationPolluted Outdoor Insulators Maintenance and Washing
Polluted Outdoor Insulators Maintenance and Washing Ali Naderian, PhD, PEng, SM IEEE Toronto, Canada February 2018 ali.naderian@ieee.org 1 برگزار کنندگان ایکهربا سامانه تجهیزات صنعت برق ایران کارشناسان
More informationEnergy Division Insulators
Energy Division http://energy.tycoelectronics.com Insulators R Insulators Tyco Electronics Energy Division covers a wide range of polymeric, hybrid and porcelain insulators. For decades all these products
More informationPerformance Analysis of 33 kv Polymer and Porcelain Insulators under Various Pollution Conditions at Costal Regions
Volume 114 No. 9 217, 1-9 ISSN: 1311-88 (printed version); ISSN: 1314-3395 (on-line version) url: http://www.ijpam.eu ijpam.eu Performance Analysis of 33 kv Polymer and Porcelain Insulators under Various
More informationINSULATORS. Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle.
Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. industry photo.
More informationHIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators
HIGH VOLTAGE INSULATORS By JP Holtzhausen The principal dielectric used on overhead power lines is air at atmospheric pressure. The air, surrounding the bare high voltage aluminium or steel- cored aluminium
More informationEffect of Metal Ring on the Field Distribution of Outdoor Polymeric Insulator
Effect of Metal Ring on the Field Distribution of Outdoor Polymeric Insulator Veeresh A G Meenakshendra A Khamitkar MTech(Power System Engineering) MTech(Power System Engineering) SDM College Of Engineering
More informationVijendra Singh Parihar 1, Prof. Anil Kumar Kori 2 1
Effects of Creepage distance on Leakage Current of 220kV Long Rod Insulators at Different Severity Level of Salt Contamination Vijendra Singh Parihar 1, Prof. Anil Kumar Kori 2 1 PG Student 2 Associate
More informationGROUP A. Polymeric Insulators.
GROUP A Polymeric Insulators PYUNGIL Bldg., 1475-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-6650~3 FAX : 82-31-424-7300 www.pyungil.com Silicone Railway
More informationENGINEERING SPECIFICATION EE SPEC
/. Company Directive ENGINEERING SPECIFICATION EE SPEC : 84/1 Relating to Surge Arresters EE SPEC : 84/1 20 December 2013-1 of 7 - IMPLEMENTATION PLAN Introduction This document defines the surge arresters
More informationINSULATOR REQUERIMENTS:
2017 INMR WORLD CONGRESS SITGES-BARCELONA, INSULATOR REQUERIMENTS: DESIGN CRITERIA, OPERATION PARAMETERS AND STANDARDS REVIEW JAVIER GARCÍA TECHNICAL AND PRODUCTION MANAGER CONTENTS q INTRODUCTION q MECHANICAL
More informationfire Charcoat Charcoat IC Passive Protection
Charcoat fire Protection Passive insulator protection Coating for the protection of pollution flashover on exterior and interior high voltage insulators Charcoat IC General information CharCoat IC is a
More informationComparison of effects of Various Contaminations on SiR insulators
Volume 120 No. 6 2018, 609-620 ISSN: 1314-3395 (on-line version) url: http://www.acadpubl.eu/hub/ http://www.acadpubl.eu/hub/ Comparison of effects of Various Contaminations on SiR insulators Satheesh
More informationEvaluation of Silicone Rubber Insulators used in High-Voltage Transmission Lines Anwar Ul-Hamid, Khaled Y. Soufi, and Ibrahim AI-Hamoudi
JMEPEG (2008) 17280-286 DOl: 10.1007/s11665-007-9142-z Evaluation of Silicone Rubber Insulators used in High-Voltage Transmission Lines Anwar Ul-Hamid, Khaled Y. Soufi, and Ibrahim AI-Hamoudi (Submitted
More informationFIBRE REINFORCED PLASTICS IN HIGH VOLTAGE APPLICATIONS
FBRE RENFORCED PLASTCS N HGH VOLTAGE APPLCATONS Volker Bergmann, Reinhausen Power Composites GmbH Page 1 OVERVEW 1. ntroduction 2. Hollow core composite insulators and their application 3. Dielectric and
More informationINCLINED PLANE TESTS OF COMPOSITE, SILICONE RUBBER AND COMPOSITE SILICONE RUBBER COATED MATERIALS
INCLINED PLANE TESTS OF COMPOSITE, SILICONE RUBBER AND COMPOSITE SILICONE RUBBER COATED MATERIALS M N R Baharom 1*, Ian Cotton 1 1 School of Electrical & Electronic Engineering, The University of Manchester,
More informationTEMPERED GLASS INSULATORS
TEMPERED GLASS INSULATORS SUSPENSION-TYPE» Non-conducing support composed of an insulating glass piece and iron fittings allowing other units to be connected in series. A fastening iron fitting is included
More informationTransmission Silicone Insulators Line Post 69 kv to 230 kv
K-LINE INSULATORS LIMITED Catalogue T-LP Transmission Silicone Insulators Line Post 69 kv to 230 kv ISO9001 SAI GLOBAL FILE No. 000117 Transmission Silicone Insulators Line Post Today transmission lines
More informationEXPERIMENTAL INVESTIGATION OF EFFECT OF UV RADIATION ON FLASHOVER VOLTAGE OF POLYMERIC INSULATORS WITH AND WITHOUT CONTAMINATION
EXPERIMENTAL INVESTIGATION OF EFFECT OF UV RADIATION ON FLASHOVER VOLTAGE OF POLYMERIC INSULATORS WITH AND WITHOUT CONTAMINATION A. Majzoobi *, I. A. Joneidi, S. Mohajer, H.Mohseni and A. A. Shayegani
More informationCHAPTER 6 HIGH VOLTAGE ELECTRICAL TESTING RESULTS
CHAPTER 6 HIGH VOLTAGE ELECTRICAL TESTING RESULTS 6.1 Introduction An electrical porcelain insulator plays an eminent role in electrical power system. As the insulators have high resistance path so it
More informationNPS/003/015 Technical Specification for 33kV, 66kV and 132kV Post Insulators
Version:- 3.1 Date of Issue:- June 2014 Page 1 of 13 NPS/003/015 Technical Specification for 33kV, 66kV and 132kV Post Insulators 1. Purpose This document is the technical specification for 33kV, 66kV
More informationPOLLUTION PERFORMANCE OF SILICONE AND EPDM INSULATOR PROFILES
Clive LUMB 22/09/05 Originally presented to CIGRE C4.3.03, submitted to 36-WG11 to illustrate: Importance of insulating length Importance of worst case and best case testing of composites. 36-WG11/Paris/216
More informationPredicting Contamination Flashover of Insulators: Successes and Shortcomings of Tests and Simulations
Predicting Contamination Flashover of Insulators: Successes and Shortcomings of Tests and Simulations Ravi S. Gorur and S. Venkataraman (Ph. D Student), Arizona State University Perhaps no single area
More informationINSULATORS NEW. See page J-4 for more information.
INSULATORS INSULATORS NEW Improved 23613 Dead End/Suspension Insulator Salisbury s Improved 23613 Dead End/Suspension Insulator has aluminum end fittings. These new end fittings create a lightweight product
More informationMaharashtra State Electricity Distribution Co. Ltd.
Maharashtra State Electricity Distribution Co. Ltd. SPECIFICATION NO. MSEDCL/ DIST/MM-III/02/2008/R1(010111) SPECIFICATION FOR L.T. PIN/SHACKLE INSULATORS Page 1 of 12 MAHARASHTRA STATE ELECTRICITY DISTRIBUTION
More informationSPECIFICATION FOR DISC INSULATORS (Standard Type)
Doc. KPLC1/3CB/TSP/04/015 1 Page 1 of 6 TABLE OF CONTENTS 0.1 Circulation List 0.2 Amendment Record FOREWORD 1. SCOPE 2. REFERENCES 3. TERMS AND DEFINITIONS 4. REQUIREMENTS 5. TESTS AND INSPECTION 6. MARKING,
More informationComposite insulators. Features. Sicat 8WL3068, 8WL3078 and 8WL3088 for overhead contact line systems. siemens.com/rail-electrification
Composite insulators Sicat 8WL3068, 8WL3078 and 8WL3088 for overhead contact line systems siemens.com/rail-electrification The Sicat 8WL3068, 8WL3078 and 8WL3088 type silicone composite insulators in accordance
More informationIEEE T&D Insulators 101
Insulators 101 Section A Introduction Presented by Andy Schwalm IEEE Chairman, Lightning and Insulator Subcommittee IEEE/PES 2010 Transmission and Distribution Conference and Exposition New Orleans, Louisiana
More informationECONOMIC ANALYSIS OF 400 KV TRANSMISSION TOWERS WITH CROSS ARMS INSULATORS
ECONOMIC ANALYSIS OF 400 KV TRANSMISSION TOWERS WITH CROSS ARMS INSULATORS Kumissay Saudeger Yildiz Technical University TURKEY Altug Bozkurt Yildiz Technical University TURKEY ABSTRACT For economic and
More informationSPECIFICATION FOR HT-LT STAY (GUY) INSULATORS:
SPECIFICATION FOR HT-LT STAY (GUY) INSULATORS:. SCOPE: This specification covers the details of the Guy (Strain) insulators Porcelain White/Brown glazed insulators suitable for G.I. Stay Wire 7/3.mm and
More informationDISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv
K-LINE INSULATORS LIMITED TORONTO, ONTARIO, CANADA Catalogue D-DS DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv ISO9001 SAI GLOBAL FILE No. 000117 Distribution Silicone Insulators
More informationNPS/001/008 Technical Specification for Gapless Metal Oxide Surge Arresters
Version:- 5.0 Date of Issue:- October 2017 Page 1 of 18 NPS/001/008 Technical Specification for Gapless Metal Oxide Surge Arresters 1. Purpose The purpose of this document is to detail the technical requirements
More informationTRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv
K-LINE INSULATORS LIMITED Catalogue TD-IPS TORONTO, ONTARIO, CANADA TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv ISO9001 SAI GLOBAL FILE No. 000117 Transmission &
More informationSPECIFICATION FOR POLYMER DISC INSULATOR
SPECIFICATION FOR POLYMER DISC INSULATOR Scope : This specification cover the design, manufacturing, testing at manufacturers works, transport to site, insurance, unloading & storage of 11 KV & 33 KV Polymer
More informationResearch methodology for the life evaluation of Hollow polymer insulators for High Voltage Applications
16th NATIONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER, 2010 687 Research methodology for the life evaluation of Hollow polymer insulators for High Voltage Applications 1. S.Farook, Research scholar,
More informationDate: TECHNICAL SPECIFICATION FOR (LT,11KV, 33KV) PORCELAIN PIN INSULATORS
Date26.09.2013 TECHNICAL SPECIFICATION FOR (LT,11KV, 33KV) PORCELAIN 1. SCOPE PIN INSULATORS The specification provides for manufacture, testing before dispatch, supply and delivery of (LT/11KV/33KV) Porcelain
More informationGeneral Requirements. Technical Specifications for Insulators of Transmission Lines
Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Insulators of Transmission
More informationPerformance investigation of composite and RTV SIR coated insulators at a coastal test station
Performance investigation of composite and RTV SIR coated insulators at a coastal test station K. Siderakis High Voltage Laboratory, Technological and Educational Institute of Crete D. Pylarinos High Voltage
More informationPorcelain versus Polymer Insulator- A Changing Era in Transmission Lines
Porcelain versus Polymer Insulator- A Changing Era in Transmission Lines K. R. Suri a, A. Gupta b, Y. Anand b, S. Anand b General Manager (Retd.), Power Grid Corporation of India Limited School of Energy
More informationGeneral Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Substation Insulators (63 kv- 400 kv)
Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Substation Insulators
More informationFailure of a suspension or tension insulator
Failure of a suspension or tension insulator Abstract:Failure of a suspension or tension insulator is clearly something that every utility or insulator manufacturer wishes would never occur. However, it
More informationOutdoor High Voltage Non-Ceramic Insulators
Outdoor High Voltage Non-Ceramic Insulators V.P. Karthika 1, P. Anitha 2, A. Hearty Rugesh 3 1 Teaching Fellow, 2 Assistant Professor, 3 UG Student 1, 2, 3 Department of EEE, Anna University, Thoothukudi
More informationDesign of MO Surge Arresters with Polymeric Housings
Design of MO Surge Arresters with Polymeric Housings Kai Steinfeld (Director R&D Surge Arresters) High Voltage Surge Arrester s Voltages in Electric Power Systems Voltage Limiting Effect of Surge Arresters
More informationSURGE ARRESTERS kv in silicone shield
SURGE ARRESTERS 10-24 kv in e shield The surge arresters 12 kv produced in Electotechnical Institute Division in Wroclaw (nominal discharge capability 10kA, 8/20µs) are presented on the picture. Advantages
More informationNEW MATERIAL TECHNOLOGY AND PROTECTION DEVICE USED IN 33/11 KV DISTRIBUTION LINE
NEW MATERIAL TECHNOLOGY AND PROTECTION DEVICE USED IN 33/11 KV DISTRIBUTION LINE Zameer Asif Khan 1, Nina Ahuja 2 1,2 Electricals & Electronics, Alfalah School of Engg. & Technology, Maharashi Dayanand
More informationTECHNICAL SPECIFICATION FOR LT PIN/SHACKLE INSULATORS
TECHNICAL SPECIFICATION FOR LT PIN/SHACKLE INSULATORS SEAL & SIGNATURE OF THE TENDERER PAGE 1 OF 11 TECHNICAL SPECIFICATION FOR LT PIN/SHACKLE INSULATORS 1.0 Scope : The specification covers the manufacture,
More informationISO Rules Part 500, Facilities Division 502, Technical Requirements Section Bulk Transmission Technical Requirements
Part 500, Facilities Division 502, Technical Requirements Section 502.2 Bulk Transmission Technical Requirements Applicability 1 This section 502.2 applies to: Requirements the legal owner of any bulk
More informationCOASTAL INDIA. Supply & Application of: Epsilon Midsun 570 Gen-4 RTV HVIC (High Voltage Insulator Coating) and
Supply & Application of: Epsilon Midsun 570 Gen-4 RTV HVIC (High Voltage Insulator Coating) and Epsilon Midsun 579 RTV Anti-Corrosion Coating In COASTAL INDIA Supply & Application of 8,000kg of Epsilon
More informationThe Effect of Severity and Location of Pollution on Leakage Current Characteristics of Porcelain Insulators under Different Humidity Condition
The Effect of Severity and Location of Pollution on Leakage Current Characteristics of Porcelain Insulators under Different Humidity Condition Ali Azizi Tousi Mohammad Mirzaie Babol University of Technology,
More informationRisk assessment of pollution on a 66kV composite insulator using ANSYS
Risk assessment of pollution on a 66kV composite insulator using ANSYS Ms. N H M Netravati 1, Mrs. Sunitha N.S 2, Dr.Shivakumara Aradhya R.S. 3, Dr. K.N Ravi 4 M.Tech. student 1, Assistant Professor 2,
More informationJournal of Operation and Automation in Power Engineering. Vol. 1, No. 2, Summer & Fall 2013, Pages:
Journal of Operation and Automation in Power Engineering Vol. 1, No. 2, Summer & Fall 2013, Pages: 74-83 http://journals.uma.ac.ir/joape Impact of Pollution Location on Time and Frequency Characteristics
More informationElectric field analysis of 132kV EPDM insulator and correlation with ageing features
2013 Electrical Insulation Conference, Ottawa, Ontario, Canada, 2 to 5 June 2013 Electric field analysis of 132kV EPDM insulator and correlation with ageing features Antonios Tzimas, Christos Zachariades
More informationPolymer and FRP Technology - An Alternative to Conventional Porcelain for Future Power Sector
Polymer and FRP Technology - An Alternative to Conventional Porcelain for Future Power Sector *Bhavani Sindhoora Velaga **Chakradhar Kaza *** Dokuparthy Narasimha Rao * &** & ***Department of Electrical
More informationGUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 220, 132 & 66 COMPOSITE SOLIDCORE STATION POST INSULATORS GETCO/E/2,1,6
More informationData Sheet 110kV TD123II dry type outdoor termination
3 Data Sheet 110kV TD123II dry type outdoor termination 1. Product Description: 3M 110kV TD123II dry type outdoor termination meets requirement of test and product according to IEC60840 and GB11017.3,
More informationNPS/003/001 Technical Specification for 33kV, 66kV and 132kV Voltage Transformers
Version:- 5.0 Date of Issue:- February 2015 Page 1 of 25 NPS/003/001 Technical Specification for 33kV, 66kV and 132kV Voltage Transformers 1. Purpose This purpose of this document is to specify the technical
More informationMGVCL/MM/1043/13-14/11 KV Disc Insulators (Porcelain)
SPECIFICATION FOR 11KV DISC. INSULATORS: - 1. SCOPE: - This specification covers 11KV Disc Type Insulators for 11KV H.T. over head power lines. 2. APPLICABLE STANDARDS: - Except when they conflict with
More informationSpecification for Polymer Disc Insulator
Specification for Polymer Disc Insulator Scope : This specification cover the design, manufacturing, testing at manufacturers works, transport to site, insurance, storage of 11 KV & 33 KV Polymer Disc
More informationCigré WG C Topics: The selection of insulators with respect to polluted conditions
Cigré Guide for the selection of insulators with respect to contamination conditions Chris Engelbrecht: Convener Topics: The selection of insulators with respect to polluted conditions Present practise
More informationData Sheet 110kV TP123-II Porcelain Insulator Outdoor Termination
3 Data Sheet 110kV TP123-II Porcelain Insulator Outdoor Termination 1 Product Description 3M 110kV TP123-II termination meets requirements of IEC60840 and GB11017.3 standards. The porcelain insulator is
More informationCOMPARATIVE LABORATORY PERFORMANCE CHARACTERISATION OF SILICONE RUBBER TEXTURED INSULATORS
COMPARATIVE LABORATORY PERFORMANCE CHARACTERISATION OF SILICONE RUBBER TEXTURED INSULATORS BY ADNAN SALAMA KRZMA B.SC., M.SC., ELECTRICAL ENGINEERING Thesis submitted to Cardiff University In candidature
More informationEffect of Some of Climatic Conditions in the Performance of Outdoor HV Silicone Rubber Insulators
Effect of Some of Climatic Conditions in the Performance of Outdoor HV Silicone Rubber Insulators By Abdelbaset Shaban Nekeb Thesis submitted to Cardiff University in candidature for the degree of DOCTOR
More informationSPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS:
SPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS: - [THIS TENDER IS FOR PURCHASE OF HT (11KV) PIN INSULATORS ONLY] 1. SCOPE: - This specification covers 11KV Disc Type & 11KV / 22KV Pin
More informationMitigating Contamination Related Issues on T&D Equipment. Lily Hoyer Simon Chan
Mitigating Contamination Related Issues on T&D Equipment Lily Hoyer Simon Chan Substation Insulator Pollution Contamination Management PRESENTED BY LILY HOYER T&D ASSET MANAGEMENT ENMAX POWER CORPERATION
More informationPanagiotis Charalampidis
Textured Insulators for Overhead Lines and Substations I. INTRODUCTION Panagiotis Charalampidis High Voltage Energy Systems Group, School of Engineering, Cardiff University, The Parade, Cardiff CF24 3AA,
More informationNATIONAL ELECTRIC POWER COMPANY (NEPCO) TENDERNO. 9/2013 FOR THE SUPPLY OF INSULATORS AND FITTINGS FOR DOUBLE AND QUADRUPLE CIRCUITS 132 kv OHTL's
TENDERNO. 9/2013 7. TECHNICAL SPECIFICATION 7.A SCOPE: This specification covers the design, manufacture, testing, packing, supply, CFR delivery to Aqaba Docks in Jordan and guarantee (maintain) the following
More information094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA
094: 2000 CEB STANDARD MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA Specification for MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEB Standard
More informationTechnical Specification for Helical Fittings for Overhead Power Lines
Ergon Energy Corporation Limited Technical Specification for Helical Fittings for Overhead Power Lines ETS01-09-03 Specification ETS01-09-03 Ver 3 Contents 1. Purpose and Scope... 4 2. References... 4
More information8. Hydrophobicity classification guide STRI guide 1.92/1 9. Radio interference characteristics of overhead power lines and high-voltage equipment
Revised in Jan 14 TECHNICAL SPECIFICATION FOR 11KV POLYMER INSULATORS (C&T) 1.0. Scope This specification covers design, manufacture, testing and supply of composite insulators for use in the 11KV overhead
More informationSPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS: -
SPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS: - 1. SCOPE: - This specification covers 11KV Disc Type & 11KV/ 22KV Pin Type Insulators for 11/22KV H.T. over head power lines. 2. APPLICABLE
More informationNotes Changed note Date. 1 (A) Changed template 09 / 07 / 2008
Revisions Notes Changed note Date 1 (A) Changed template 09 / 07 / 2008 2 Changed template. Clause 12.5.4.1 hot-rolled steel added. Clause 12.5.4.2, 12.5.2.4, 12.5.3.4, 12.5.4.4, 12.5.5.4, 12.5.6.4, 12.5.7.4
More information15~35KV Termination Kit
15~35KV Termination Kit Luyon Corporation 21221 Western Ave., #210 Torrance, CA 90501, U.S.A. Advantages of Silicone Rubber Power Cable Accessories Feature of silicone rubber: Silicone rubber is a unique
More informationSPECIFICATION OF HT-LT STAY (GUY) INSULATORS:
1. SCOPE: SPECIFICATION OF HT-LT STAY (GUY) INSULATORS: This specification covers the details of the Guy (Strain) insulators Porcelain White/Brown glazed insulators suitable for G.I. Stay Wire 7/3.15mm
More informationESDD MEASUREMENTS IN THE POWER SYSTEM OF CRETE
ESDD MEASUREMENTS IN THE POWER SYSTEM OF CRETE Dionisios PYLARINOS Consultant, Hellenic Electricity Distribution Network Operator S.A., Greece dpylarinos@yahoo.com Kiriakos SIDERAKIS Assistant Professor,
More informationPERFORMANCE ANALYSIS OF OVERHEAD PORCELAIN INSULATOR UNDER DIFFERENT CONTAMINATIONS
International Journal of Mechanical Engineering and Technology (IJMET) Volume 8, Issue 10, October 2017, pp. 241 245, Article ID: IJMET_08_10_028 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=10
More informationA-PDF PPT TO PDF DEMO: Purchase from to remove the watermark
EMERGING TECHNOLOGIES SILIDRIL - Polymeric Coating & SHRIJI - CONDUCTIVE SILICON GEL By: Surat Prestech Pvt. Limited Prepared By Mr. Nitin Oza, M.E. & Dr. Rafael Mier, PhD. A-PDF PPT TO PDF DEMO: Purchase
More informationESDD PREDICTION OF OUTDOOR POLYMER INSULATORS. Abdelrahman Khaled
ESDD PREDICTION OF OUTDOOR POLYMER INSULATORS by Abdelrahman Khaled A Thesis Presented to the Faculty of the American University of Sharjah College of Engineering in Partial Fulfillment of the Requirements
More informationMapping HV Insulators Pollution in the Mediterranean Island of Crete
1 Mapping HV Insulators Pollution in the Mediterranean Island of Crete D. Pylarinos, K. Siderakis, N. Mavrikakis, E. Thalassinakis Abstract The reliability of High Voltage insulators is rather important
More informationPolymer Station Post Insulators for 69 to 345 kv Applications
CATALOG 143 Polymer for 69 to 34 kv Applications NGK-Locke Polymer Insulators, Inc. Virginia Beach, Virginia, U.S.A. TABLE of CONTENTS Polymer... 1 Application Guidelines for Polymer Station Posts (SP)...
More informationACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL P. RANACHOWSKI, Z. RANACHOWSKI, F. REJMUND J. STANKIEWICZ
ARCHIVES OF ACOUSTICS 30, 1, 121 130 (2005) ACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL P. RANACHOWSKI, Z. RANACHOWSKI, F. REJMUND Institute of Fundamental Technological Research Polish Academy
More informationExperimental analysis of hydrophobic characteristics of Silicone rubber (SiR) insulators under different climatic conditions
International Journal of Physical Sciences Vol. 7(47), pp. 6162-6168, 16 December, 2012 Available online at http://www.academicjournals.org/ijps DOI: 10.5897/IJPS12.508 ISSN 1992-1950 2012 Academic Journals
More informationPolymer Suspension Insulators 69kV to 765kV
CATALOG Polymer Suspension Insulators 69kV to 765kV NGK Locke Polymer Insulators, Inc. Virginia Beach, Virginia, U.S.A. TABLE of CONTENTS Table of Contents... 1 Design Features... 2 Material... 2 Definition
More informationA Study of Critical Positive Impulse Flashover of 24 kv Contaminated Insulators
The 5 th PSU-UNS International Conference on Engineering and 467 Technology (ICET-2011), Phuket, May 2-3, 2011 Prince of Songkla University, Faculty of Engineering Hat Yai, Songkhla, Thailand 90112 Study
More informationVeri*Lite Deadend, Suspension & Line Post Insulators for 15-69kV Applications
Veri*Lite Deadend, Suspension & Line Post Insulators for 569kV Applications Section Warranty Material Hubbell Power Systems, Inc. warrants all products sold by it to be merchantable (as such term is defined
More informationSelection between indoor or outdoor DC yards D. WU*, U. ÅSTRÖM, L. ARÉVALO, R. MONTAÑO, B. JACOBSON ABB HVDC SWEDEN
21, rue d Artois, F-75008 PARIS B3-115 CIGRE 2014 http : //www.cigre.org Selection between indoor or outdoor DC yards D. WU*, U. ÅSTRÖM, L. ARÉVALO, R. MONTAÑO, B. JACOBSON ABB HVDC SWEDEN SUMMARY In an
More informationPotential and E-Field Calculation Along an Ice- Covered Composite Insulator with Finite Element Method
Potential and E-Field Calculation Along an Ice- Covered Composite Insulator with Finite Element Method Qing Yang, Caixin Sun, Wenxia Sima, Lichun Shu, Ji Yang, Jianlin Hu The Key Laboratory of High Voltage
More information11KV PORCELAIN INSULATORS AND FITTINGS
REC Specification 3/1971 (Revised 1993) 11KV PORCELAIN INSULATORS AND FITTINGS FOREWORD This specification was originally issued in 1971 on the basis of the decisions taken in the First and Second Standardisation
More informationStation Post Insulators (SPI), an Emerging Application for Composite Hollow Core Insulators PETER STAHL
Station Post Insulators (SPI), an Emerging Application for Composite Hollow Core Insulators PETER STAHL Composite Hollow Core Station Post Insulators (SPI) Peter Stahl, July 2015 Applications for composite
More informationDESIGN TEST REPORT. GAMMA Insulators 6184R-70 ANSI Class 55-3 Pin Type Insulator..
December 4, 2010 DESIGN TEST REPORT Insulator Reference: GAMMA Insulators 6184R-70 ANSI Class 55-3 Pin Type Insulator.. Electrical Design Tests 1. Low-Frequency Dry Flashover Test: Three insulators were
More informationDESIGN TEST REPORT. GAMMA Insulators 7061R-70 ANSI Class 55-5 Pin Type Insulator.
December 6, 2010 DESIGN TEST REPORT Insulator Reference: GAMMA Insulators 7061R-70 ANSI Class 55-5 Pin Type Insulator. Electrical Design Tests 1. Low-Frequency Dry Flashover Test: Three insulators were
More informationDESIGN TEST REPORT. GAMMA Insulators 6183R-70 ANSI Class 55-4 Pin Type Insulator.
December 2, 2010 DESIGN TEST REPORT Insulator Reference: GAMMA Insulators 6183R-70 ANSI Class 55-4 Pin Type Insulator. Electrical Design Tests 1. Low-Frequency Dry Flashover Test: Three insulators were
More informationInnovative New Live Line Tool and Framing Designs Facilitating Safe and Efficient Cross-arm Replacement
Innovative New Live Line Tool and Framing Designs Facilitating Safe and Efficient Cross-arm Replacement A.J. Carreira, P.Eng., SMIEEE President Toronto, Canada carreira@k-line.net ISSUES WITH CURRENT CROSS
More informationCS type composite silicone insulators up to 750 kv overhead lines for all pollution of the atmosphere levels
Climate test equipment. Allows to perform test in various temperature and humidity conditions. CS type composite silicone insulators up to overhead lines for all pollution of the atmosphere levels Insulators
More informationMaharashtra State Electricity Distribution Co. Ltd.
Maharashtra State Electricity Distribution Co. Ltd. SPECIFICATION NO. MSEDCL/ DIST:MM-III/06/2006 SPECIFICATION FOR H.T.DISC INSULATORS 1 TECHNICAL SPECIFICATION FOR 11 KV 45 KN / 70 KN DISC INSULATORS
More informationINSULATION, ASSET AND WILDLIFE PROTECTION Steve Parker, Business Development
INSULATION, ASSET AND WILDLIFE PROTECTION Steve Parker, Business Development MARKET FORCES THAT INFLUENCE RAYCHEM SALES PUBLIC UTILITY COMMISSIONS (System Reliability) SALES US FISH & WILDLIFE (Avian Electrocutions)
More informationComparative study on field collected samples of aged silicon rubber composite coatings for high voltage insulators
DOI: 10.2478/achi-2013-0009 ACTA CHEMICA IASI, 21_2, 93-106 (2013) Comparative study on field collected samples of aged silicon rubber composite coatings for high voltage insulators I.V. Tudose, 1,4 M.
More informationTECHNICAL SPECIFICATION FOR 11 POST INSULATORS, 11 KV & 33 KV PIN INSULATORS AND 11 KV, B&S TYPE 45 KN & 70 KN DISC INSULATORS.
Vidyut Bhavan( 4th Floor),Bidhannagar, Block-DJ Sector-II Kolkata-700 091 Phone No.033-2359-8397 Fax No.033-2359-1921 TECHNICAL SPECIFICATION FOR 11 POST INSULATORS, 11 KV & 33 KV PIN INSULATORS AND 11
More informationTECHNICAL SPECIFICATION FOR 11 KV & 33 KV POST INSULATORS, 11 KV & 33 KV PIN INSULATORS AND 11 KV, B&S TYPE 45 KN & 70 KN DISC INSULATORS.
Vidyut Bhavan( 4th Floor),Bidhannagar, Block-DJ Sector-II, Kolkata-700 091 TECHNICAL SPECIFICATION FOR 11 KV & 33 KV POST INSULATORS, 11 KV & 33 KV PIN INSULATORS AND 11 KV, B&S TYPE 45 KN & 70 KN DISC
More information