DuPont Tyvek Fluid Applied WB - Commercial Installation Guidelines

Size: px
Start display at page:

Download "DuPont Tyvek Fluid Applied WB - Commercial Installation Guidelines"

Transcription

1 DuPont Tyvek Fluid pplied W DuPont Tyvek Fluid pplied Flashing and Joint ompound DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines METHODS FOR SUPERIOR PROTETION GINST IR ND WTER INTRUSION

2 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines DuPont Tyvek Fluid pplied ir arrier System DuPont Tyvek Fluid pplied W DuPont Tyvek Fluid pplied weather barrier (W) is a vapor permeable, low VO, single-component product with excellent elasticity and flexibility. It is easily applied in one coat and has extremely low shrinkage during curing. DuPont Tyvek Fluid pplied Flashing and Joint ompound full bodied, trowel applied, vapor permeable elastomeric flashing material. It is used to coat rough openings for windows and doors, to fill seams, cracks and holes in the substrate, to seal around penetrations and to treat joints and transitions between building components. DuPont Tyvek Fluid pplied Flashing - rush Formulation brush applied, vapor-permeable elastomeric flashing material used to coat rough openings for windows and doors. DuPont Sealant for Tyvek Fluid pplied System Non-vapor permeable sealant specifically designed to work with the DuPont Tyvek Fluid pplied system. DuPont Sealant for Tyvek Fluid pplied System has excellent adhesion and elongation. It should be used to seal around window, doors, and penetrations. DuPont ommercial Self-dhered Flashing DuPont StraightFlash premium self-adhered membrane used for flashing windows and doors, to treat transitions and for terminations. It is made with DuPont Tyvek and a 100% butylbased adhesive layer. DuPont FlexWrap NF premium extendable self-adhered flashing material that efficiently conforms around corners and irregular shapes. It is made with DuPont Tyvek and a 100% butyl-based adhesive layer. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 2

3 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Table of ontents pplicable Products... 3 Recommended Primers... 3 Weather arrier and Energy onservation odes and Standards... 4 Warranty Information... 4 Special onsiderations for MU... 4 Installation Instructions... 5 Detailing... 6 Foundation... 6 Top of Wall... 6 Transitions... 7 Transitions to DuPont Tyvek uilding Wrap Products... 8 Penetrations... 8 rick Ties, ladding Supports, and Furring Strips... 9 pplication Over Sheathing... 9 Joint Treatment Methods Repair Equipment Recommendations lean Up Health and Safety Disposal Facade/Exterior onsiderations pplicable Products Fluid pplied Products PRODUT QUNTITY OVERGE DuPont Tyvek Fluid pplied W 5 gal, 50 gal sf/gal* DuPont Tyvek Fluid pplied Flashing and Joint ompound 10.3 oz, 28 oz, 3.5 gal sf/gal* DuPont Tyvek Fluid pplied Flashing and Joint ompound (for gypsum sheathing seam treatment) 10.3 oz, 28 oz, 3.5 gal lf/oz DuPont Tyvek Fluid pplied Flashing - rush Formulation 10.3 oz, 28 oz, 3.5 gal sf/gal* DuPont Sealant for Tyvek Fluid pplied System 10.3 oz, 28 oz N/ * Estimated surface coverage at 25 mils thick. Self-dhered Flashing Products PRODUT DIMENSIONS RE DuPont FlexWrap NF 6 in x 75 ft sq ft 9 in x 75 ft sq ft DuPont StraightFlash 4 in x 150 ft 50 sq ft 9 in x 125 ft sq ft Recommended Primers* (for self-adhered flashing) MNUFTURER PRODUT NME 3M Hi-Strength 90** Denso utyl Primer (spray or can) * pply per manufacturers guidelines. DuPont assumes no liability in use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications. **3M Hi-Strength 90 is recommended to be used with DuPont Tyvek Fluid pplied products. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 3

4 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Weather arrier & Energy onservation odes and Standards The 2009 International uilding ode (Section Weather Protection) requires that exterior walls shall provide the building with a weather resistant exterior wall envelope. The exterior wall envelope shall include flashing, as described in Section DuPont Tyvek Fluid pplied System has been tested to the following standards. STM E 331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and urtain Walls by Uniform Static Pressure STM E 2178 Standard Test Method for ir Permeance of uilding Materials STM E 2357 Standard Test Method for Determining ir Leakage of ir arrier ssemblies STM E 283 Standard Test Method for Determining Rate of ir Leakage Through Exterior Windows, urtain Walls and Doors Under Specified Pressure Differences cross the Specimen. Energy onservation odes for commercial buildings are being adopted in many regions across the U.S. DuPont Tyvek Fluid pplied Weather arrier System products meet the following codes and guidelines. SHRE 90.1 Model Energy ode air barrier requirements Minnesota ommercial Energy ode, Section , Section Massachusetts State uilding ode 780 MR 120. Wisconsin uilding ode, Energy onservation, hapter omm 63 Michigan uilding ode Rhode Island uilding ode Georgia uilding ode Florida uilding ode Warranty Information If interested in reviewing warranty coverage, please see DuPont Tyvek Fluid pplied W Products 10 Year limited warranty at Special onsiderations 1. Suitable substrates for Tyvek Fluid pplied products include concrete masonry unit (MU), concrete (48 hrs. for green concrete), exterior gypsum, OS, plywood, wood, treated wood and metal. 2. Tyvek Fluid pplied products can be applied to damp surfaces. surface is considered damp if there is no visible water on the surface and no transfer of water to the skin when touched. 3. Tyvek Fluid pplied products are designed for above grade application and should not be installed below grade. 4. Tyvek Fluid pplied products should be applied when air and surface temperatures are above 25 F. 5. Tyvek Fluid pplied products may be overcoated once a touch-free skin has formed. Exterior insulation and/or cladding may be installed once the membrane has cured sufficiently to resist damage during installation. Skin time is 1-2 hrs, and 25 mil fully cures in 24 hrs at 70 F (20 ), 50% RH. 6. Tyvek Fluid pplied products should be stored in a clean, dry environment, at F, (10-27 ). Storage of the products in temperatures outside that range for short periods of time can be acceptable. Products temporarily stored outside should be stored under cover. 7. Opened pails and drums of fluid applied product should be covered with plastic to slow cure rate. 8. DuPont requires that fluid applied product be covered within 9 months of installation. 9. DuPont self-adhered flashing products perform best when air and surface temperatures are above 25 F ( 4 ). 10. recommended primer is required when applying DuPont self-adhered flashing products on concrete, masonry, and fiber faced exterior gypsum board substrates. Priming is generally not required for adhering DuPont self-adhered flashing products to wood. However, adverse weather conditions or colder temperatures may require a primer to promote adhesion. Priming is not required when applying Tyvek Fluid pplied products, except when applying onto cut edges of exterior gypsum sheathing. 11. DuPont Tyvek Fluid pplied products must not come in contact with the building wrap products due to potential impact on performance properties. See page 8 for transitions to DuPont Tyvek buildingwrap products. For additional guidance, please call Tyvek ( ), visit our website at or consult your local DuPont Tyvek Specialist. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 4

5 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Installation Instructions STEP 1: PREPRTION lean substrate by removing any material that may affect the adhesion of DuPont Tyvek Fluid pplied products, such as frost, oil, grease, mold and efflorescence. Remove all dust, dirt and loose mortar from the substrate using a trowel and brush. DuPont Tyvek Fluid pplied products can be applied to damp masonry. Striking the MU joints flat is recommended. STEP 2: FLSHING 2. Install a DuPont recommended through wall flashing at all necessary locations (e.g. base of the wall, shelf angles, heads of windows, etc.) 2. Install DuPont Tyvek Fluid pplied Flashing or DuPont self-adhered flashing around windows and doors in accordance with the DuPont Tyvek Fluid pplied Flashing - ommercial Installation Guidelines. Visit STEP 4: WETHER RRIER Tyvek Fluid pplied W may be sprayed, brushed or rolled, however application using a pressure roller such as the Graco Pressure Roller, or equivalent, is the preferred method. roller cover with a 1/4 3/8 nap is recommended. When applying by spray, back rolling is also necessary. Tyvek Fluid pplied W needs only to be applied in a single coat at 25 mils thick (yielding approximately 55 sf/gal on MU). Thickness should be controlled by applying the appropriate volume over a marked area and by spot checking with a wet mil gauge. Integrate Tyvek Fluid pplied W with through wall flashing and window/door flashing by overlapping the flashing with Tyvek Fluid pplied W by a minimum of 2. Upon completion, inspect the membrane to ensure that it is continuous and free of any voids or pinholes. See Special onsideration #5, on page 4, for exterior insulation and cladding installation recommendations. STEP 3: WLL/SUSTRTE PREPRTION 3. Fill small cracks and voids in masonry with DuPont Tyvek Fluid pplied Flashing and Joint ompound. Large voids should be filled flush with mortar and allowed to cure. 3. Seal around all penetrations using Tyvek Fluid pplied Flashing and Joint ompound or Sealant for Tyvek Fluid pplied System. The fillet bead should extend ½ onto both surfaces (see page 8 for detail). 3. s a best practice DuPont recommends that all embedded masonry anchors be treated by applying a coat of Tyvek Fluid pplied W or Fluid pplied Flashing and Joint ompound around the base of the anchor (see page 9 for additional fastening recommendations). 3D. Treat all non-moving transition joints to beams, columns, and dissimilar materials by applying a 2 wide, 60 mil thick coat of Fluid pplied Flashing and Joint ompound across the joint (grouted joints between similar materials do not need to be treated). Joints up to ¼ can be treated with joint compound alone. Joints from ¼ - ½ should be reinforced with fiberglass mesh tape. lternatively, joints and transitions may be treated using DuPont StraightFlash (see Special onsideration #10, on page 4, for priming requirements). Flashing should extend a minimum of 2 onto each surface (see page 7 for detail). Refer to page 10 for sheathing joint treatment recommendations. 3E. Treat all inside and outside corners by applying a 25 mil thick coat of Tyvek Fluid pplied, 2 onto each adjoining surface. It is recommended that a fillet bead of Tyvek Fluid pplied be applied to inside corners to help ensure continuity. lternately, corners may be treated using DuPont StraightFlash. e sure that DuPont StraighFlash is pressed tightly into the inside corners and is fully adhered to substrate (see Special onsideration #10, on page 4, for priming requirements) E D 2 2 NOTE: s a best practice DuPont recommends that all flashing and detailing work be completed prior to the application of Tyvek Fluid pplied W. Tyvek Fluid pplied products may be overcoated once a touch-free skin has formed. Skin time is 1-2 hrs at 70 F (20 ), 50% RH. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 5

6 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Detailing It is important to maintain the continuity of the weather barrier from top to bottom. The entire wall surface shall be covered, including unconditioned spaces. Special attention should be given to all terminations, transitions, projections and penetrations to ensure a proper drainage plane and a continuous weather barrier is maintained. Foundation. Install a DuPont recommended through wall flashing in accordance with the through wall flashing manufacturer s installation guidelines.. pply any necessary Tyvek Fluid pplied pretreatment, flush with the top of the through wall flashing.. Seal top edge of through wall flashing using DuPont Sealant for Tyvek Fluid pplied System or Tyvek Fluid pplied Flashing and Joint ompound. llow the Tyvek Fluid pplied product to form a touch-free skin, before applying DuPont Tyvek Fluid pplied W. Skin time is 1-2 hrs at 70 F (20 ), 50% RH. D. pply DuPont Tyvek Fluid pplied W onto wall surface at 25 mils thick. Overlap through wall flashing by a minimum of 2. Top of Wall. DuPont Tyvek Fluid pplied W should be installed prior to the installation of the DuPont recommended parapet flashing membrane.. pply a liberal bead of DuPont Sealant for Tyvek Fluid pplied System or Tyvek Fluid pplied Flashing and Joint ompound onto the Tyvek Fluid pplied W at a location that will be approximately 2 up from the bottom edge of the flashing.. Install parapet flashing over the top of wall per parapet flashing manufacturer s guidelines, extending it down over Tyvek Fluid pplied W by at least 4. D. Press flashing into sealant and secure using mechanical fasteners installed through the flashing and sealant bead. 4 D 2 D 1/4 drip edge opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 6

7 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Transitions METHOD 1* (fluid applied flashing). lean both substrates thoroughly. Remove any material that could negatively affect adhesion.. Fill seam between adjoining substrates flush with the surface using DuPont Tyvek Fluid pplied Flashing and Joint ompound. Joints up to ¼ can be treated with Tyvek Flashing and Joint ompound only. Joints from ¼ - ½ should first be reinforced with fiberglass mesh tape or filled with mortar.. pply a bead Tyvek Fluid pplied Flashing and Joint ompound to both adjoining surfaces and spread material across transition seam to a width of approximately 2 and 60 mils thick. Upon completion, inspect transition treatment for thin spots, gaps or pinholes and repair as necessary. D. llow the Tyvek Fluid pplied product to form a touch-free skin, before applying DuPont Tyvek Fluid pplied W. Skin time is 1-2 hrs, at 70 F (20 ), 50% RH. * For non-moving joints only. METHOD 2* (self-adhered flashing). lean both substrates thoroughly. Remove any material that could negatively affect adhesion.. Prime both substrates using a DuPont recommended primer.. pply a strip of DuPont StraightFlash to the primed substrates. Flashing should extend a minimum of 2 onto each surface. Press StraightFlash firmly onto both surfaces, working it into any irregularities using a J-roller or firm hand pressure. * For non-moving joints only. 2 2 D D opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 7

8 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Transitions to DuPont Tyvek uilding Wrap. Install DuPont Tyvek building wrap products per DuPont Installation Guidelines prior to application of DuPont Tyvek Fluid pplied W.. Fasten building wrap to the stud adjoining the transition substrate.. ut DuPont Tyvek building wrap so that approximately 3 will overlap the adjoining substrate. D. Fold back the 3 flap of building wrap and prime adjoining substrate with a DuPont recommended primer. E. Fold building wrap back down over the interface and seal it to the primed substrate using 4 DuPont StraightFlash, overlapping both surfaces evenly by approximately 2. Press DuPont StraightFlash firmly onto any irregular surfaces using a J-roller or firm hand pressure. F. Lastly, apply Tyvek Fluid pplied W onto wall surface, and onto DuPont StraightFlash. Tyvek Fluid pplied W should overlap StraightFlash by a minimum of 2. Do not apply Tyvek Fluid pplied W onto Tyvek building wrap. Upon completion, inspect surface to ensure that Tyvek Fluid pplied W is continuous and free of any voids or pinholes. 3 Penetrations. lean both substrates.. Seal around penetration using DuPont Tyvek Fluid pplied Flashing and Joint ompound or Sealant for Tyvek Fluid pplied System. Upon completion, inspect Tyvek Fluid pplied for gaps or pinholes and repair as necessary.. Tyvek Fluid pplied should extend a minimum of ½ onto both surfaces. llow product to form a touch-free skin, before applying DuPont Tyvek Fluid pplied W. Skin time is 1-2 hrs, at 70 F (20 ), 50% RH. 1/2 D E F opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 8

9 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines rick Ties, ladding Supports, and Furring Strips s a best practice, DuPont recommends that all embedded masonry anchors be treated by applying a coat of DuPont Tyvek Fluid pplied W or DuPont Tyvek Fluid pplied Flashing and Joint ompound around the base of the anchor. When installing mechanically attached supports or furring strips in high performance building envelope designs (building envelope design requirements exceeding STM E 1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infiltration testing), fasteners shall be sealed by, 1) applying a piece of double sided butyl tape to the back of support bracket at the fastener location, or 2) embedding support bracket into an additional wet bed of a DuPont Tyvek Fluid pplied product, or 3) applying a coat of DuPont Tyvek Fluid pplied product to the screw before installing, or 4) an alternate DuPont approved method. When installing mechanically attached supports or furring strips in building envelope design requirements equivalent to STM E 1677 conditions or less, no pretreatment is necessary. pplication Over Sheathing DuPont Tyvek Fluid pplied W may be installed over exterior gypsum, OS, and plywood sheathing. Sheathing should be clean and free from any materials that could negatively affect adhesion. When installing over sheathing, it is important that all sheathing seams be pretreated using the appropriate joint treatment method (see page 10). ll flashing and detailing should be completed before installation of DuPont Tyvek Fluid pplied W. When applying over exterior gypsum, all cut edges along outside corners and rough openings should first be primed with a recommended primer. Pretreat all inside and outside corners by applying a 25 mil thick coat of Tyvek Fluid pplied, 2 onto each adjoining surface. It is recommended that a fillet bead of Fluid pplied be applied to inside corners to help ensure continuity. lternately, corners may be treated using DuPont StraightFlash. e sure that DuPont StraighFlash is pressed tightly into the inside corners and is fully adhered to substrate (see Special onsideration #10, on page 4, for priming requirements). Tyvek Fluid pplied W may be brushed, rolled or spray applied. However, application using a pressure roller such as Graco Pressure Roller, or equivalent, is the preferred method. roller cover with a 1/4 3/8 nap is recommended. When applying by spray, the surface should be back rolled to insure a pinhole free surface. Fluid pplied W should also be applied in a single coat at 25 mils thick (yielding approximately 65 sf/gal on exterior gypsum). The thickness should be controlled by applying the appropriate volume over a marked area and by spot checking with a wet mil gauge. Upon completion, inspect the membrane to ensure that it is continuous and free of any voids or pinholes. Tyvek Fluid pplied products may be overcoated once a touch-free skin has formed. Exterior insulation and/or cladding may be installed once the membrane has cured sufficiently to resist damage during installation. Skin time is 1-2 hrs, and 25 mil fully cures in 24 hrs at 70 F (20 ), 50% RH. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 9

10 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Joint Treatment Methods Joint treatment is not necessary for gaps 1/16 wide or less. Method 1 (for gaps up to 1/4 ). pply a bead of DuPont Tyvek Fluid pplied Flashing and Joint compound above and below the sheathing seam.. Smooth joint compound across the joint using a trowel. Joint ompound should extend a minimum of 1 on either side of the joint and be mils thick.. heck joint for thin spots and pinholes, repair as necessary. Method 2 (for gaps up to 1/2 ). Firmly apply self-adhered reinforcing mesh tape.. pply a bead of Tyvek Fluid pplied Flashing and Joint ompound above and below the sheathing seam.. Smooth joint compound across the mesh tape using a trowel. Joint compound should extend a minimum of 1 on either side of the joint and be mils thick. D. heck joint for thin spots and pinholes, repair as necessary. Method 3 (for gaps up to 1 ). pply recommended primer above and below sheathing joint.. enter DuPont StraightFlash over joint and firmly press onto sheathing using a J-roller or firm hand pressure. Method 1 1/16-1/4 Method 2 1/4-1/2 Method 3 1/2-1 Repair Small repairs can be made by coating the damaged area with a layer of Tyvek Fluid pplied product. Larger damaged areas may need to be reinforced using fiberglass mesh or by replacing damaged substrate before reapplying Tyvek Fluid pplied product. Equipment Recommendations pplication using a pressure roller, such as the Graco Pressure Roller, is the preferred method of installation of Tyvek Fluid pplied W. pressure roller can be used in conjunction with a variety of pumps, such as the Graco TexSpray Mark V, TexSpray 7900 HD, GH 733, GH 833 or equivalent. Tyvek Fluid pplied W can be sprayed using a high pressure air-powered, airless sprayer such as the Graco X70 Xtreme Sprayer or equivalent. The recommended tip sizes are minimum hose diameter of 3/8 should be used when spray applying. ll internal filters should be removed from the pump, spray gun, and pressure roller assembly, before applying product. The pump intake screen should be installed when applying product. The condition of the pump, as well as the size, length, and condition of the hoses used can affect the systems performance. The diameter of some hose sections may need to be increased, depending on the pumping distance desired. Refer to pump manufactures representative and guidelines regarding the operation and maintenance of the pump system. Operation of pump equipment can be hazardous. ll manufacturer limitations, warnings, and safety recommendations should be followed. lean Up Uncured material can be cleaned from hands, tools, and equipment by using a citrus based cleaner or standard mineral spirits. ured product can be removed by soaking in a solvent or gel-based paint stripper. Tyvek Fluid pplied W is a moisture cure product and will react with water based products. When applying with a pump system, be sure that the system is completely clean of any incompatible materials before use. If the system is not completely clean or if moisture is present in the system, the product may react and cure in the system. Tyvek Fluid pplied W should not be stored in the pump, hose, gun, or pressure roller. fter application is complete, flush the system with a citrus based cleaner, or standard mineral spirits until the system is clean. Low pressure portions of the pump should be taken apart and cleaned by hand to promote optimal pump performance. efore each use, flush any remaining solvent out of the system before applying Tyvek Fluid pplied W to the wall. Refer to pump manufacturer instructions for additional cleaning and storage recommendations. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 10

11 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Health and Safety Tyvek Fluid pplied System products contain calcium carbonate, vinyl trimethoxysilane and diaminopropyl trimethoxysilane. Vapor harmful if using spray application. Use in a well ventilated area. Use a NIOSH approved respirator. If vapors are inhaled, immediately remove from exposure and contact a physician. void contact with eyes and skin. Protective eye wear and gloves are recommended. Refer to the MSDS for complete health and safety information. Visit Tyvek Fluid pplied website at Disposal Dispose of any residual fluid applied material or fluid applied coated debris in accordance with applicable federal, state, and local government regulations. Facade/Exterior onsiderations NOTE: Refer to Special onsideration #5, on page 4, for exterior insulation and cladding installation recommendations. rick The rick Industry ssociation recommends a 1 air-space in front of wood stud construction and a 2 air-space in front of steel stud construction. onsistent with these requirements and recommendations, Tyvek Fluid pplied W shall be separated from the brick veneer by a minimum 1 air-space. Window and door flashing and through wall flashing shall be integrated with the DuPont Tyvek Fluid pplied W in accordance with these installation guides. For maximum moisture management and drying of the wall system, the airspace in front of the Fluid pplied W shall be vented to the exterior at the top and bottom of the wall. Stucco When stucco is installed over wood-based sheathing the 2009 International uilding ode (Section ) requires a water-resistive vapor-permeable barrier with a performance at least equivalent to two layers of Grade D paper or a layer of weather barrier which is separated from the stucco by an intervening layer. When the DuPont Tyvek Fluid pplied W is used behind stucco, it should be separated from the stucco by an intervening layer per section of the 2009 International uilding ode. DuPont Tyvek Fluid pplied W will serve as the wall system s primary weather barrier and should be integrated with the window and door flashings, the weep screed at the bottom of the wall and any through wall flashings or expansion joints. Lath shall be installed over the intervening layer (second layer) in accordance with STM Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland ement-ased Plaster and applicable codes. Metal Panel When used with DuPont Tyvek Fluid pplied W, metal panel cladding systems shall be installed according to manufacturer s instructions and industry standards. Window and door flashing and through wall flashing shall be integrated with the Tyvek Fluid pplied W. Stone Veneer The 2009 International uilding ode (Section1405.7) requires two layers of a waterresistive barrier behind stone veneers over framed construction. When used behind stone veneer, DuPont Tyvek Fluid pplied W shall be installed in a similar manner as it is behind stucco. When installed over wood frame construction, DuPont Tyvek Fluid pplied W should be separated from the stone and mortar by an intervening layer (second layer) of a DuPont Tyvek building wrap, a layer of grade D building paper, felt, rigid foam board or the paper backing of paper-backed lath. The DuPont Tyvek Fluid pplied W will serve as the wall systems primary weather barrier and should be integrated with the window and door flashings, the weep screeds at the bottom of the wall and any through wall flashings or expansion joints. Lath shall be installed over the intervening layer (second layer) in accordance with STM Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland ement-ased Plaster and applicable codes. Wood Siding When used with DuPont Tyvek Fluid pplied W, and wood siding shall be installed according to manufacturer s instructions, industry standards and applicable codes. s recommended by the Western Red edar Lumber ssociation and U. S. Forest Product Laboratory, wood siding should be primed on all six sides before installation. In high exposure installations, enhanced drainage and water management may be provided by using DuPont Tyvek ommercialwrap D or by creating rainscreen cladding with a larger airspace behind the siding using furring strips. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 11

12 DuPont Tyvek Fluid pplied W - ommercial Installation Guidelines Fiber ement Siding When used with DuPont Tyvek Fluid pplied W, fiber cement siding shall be installed according to manufacturer s instructions and industry standards. In high exposure installations, enhanced drainage and water management may be provided by using DuPont Tyvek ommercialwrap D or by creating rainscreen cladding with a larger airspace behind the siding using furring strips. Exterior Insulation Exterior Insulation should be installed after the appropriate flashing materials have been installed and DuPont Tyvek Fluid pplied W has been applied and properly integrated with flashing. Exterior insulation shall be installed in accordance with manufacture s guidelines and industry standards. The level of performance of exterior insulation (continuous insulation) is dependent upon proper installation and continuity limitations due to the design of the building envelope. opyright 2012 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 4/12 12

13 Technical Specifications DuPont Tyvek Fluid pplied products are formulated to include elastomeric polymers that cure to continuous, fully-adhered, tough, durable membranes. dditives have been incorporated to provide ultraviolet light resistance. DuPont requires that the DuPont Tyvek Fluid pplied W, DuPont Tyvek Fluid pplied Flashing and Joint Treatment ompound, and DuPont Tyvek Fluid pplied rush Formulation are to be covered within 9 months (270 days) of installation.. DuPont FlexWrap NF and StraightFlash flashing products are made from a synthetic rubber adhesive and a top sheet of flash spunbonded high density polyethylene fibers. dditives have been incorporated into these materials to help provide UV light resistance. DuPont requires that DuPont FlexWrap NF and StraightFlash be covered within (4) four months (120 days) of installation. Warning DuPont Tyvek Fluid pplied products should be used only as directed. void contact with eyes and skin, gloves are recommended. First id: Eye & Skin ontact; Wash thoroughly with water. If irritation persists, contact a physician. KEEP OUT OF REH OF HILDREN. DuPont FlexWrap NF and DuPont StraightFlash products and their release paper are slippery and should not be walked on. Remove release paper from work area immediately. DuPont FlexWrap NF and DuPont StraightFlash will melt at temperatures greater than 250 F (121 ). DuPont self-adhered flashing products are combustible and should be protected from flame and other high heat sources. If burning occurs, ignited droplets may fall away from the point of ignition. For more information, call Tyvek. Note When installed in conjunction with other building materials, DuPont Tyvek Fluid pplied products must be properly integrated so that water is diverted to the exterior of the wall system. DuPont Tyvek Fluid pplied W is a secondary weather barrier. The outer facade is the primary barrier. You must follow facade manufacturer s installation and maintenance requirements for all facade systems in order to maintain water holdout properties and ensure performance of Tyvek Fluid pplied W. Use of additives, coatings or cleansers on or in the facade system may impact the performance of Tyvek Fluid pplied products. Tyvek Fluid pplied W is to be used as outlined in this installation guideline. Tyvek Fluid pplied flashing products and DuPont self-adhered flashing products should only be used to seal penetrations and flash openings in houses or buildings. DuPont Tyvek Fluid pplied Products must not come in contact with building wrap products due to potential impact on performance properties. Tyvek Fluid pplied products are not to be used in roofing applications. For superior protection against bulk water penetration, DuPont suggests a system combining a quality exterior facade, a good secondary weather barrier and exterior sheathing, high quality windows and doors, and appropriate flashing materials paying attention to proper installation of each component. DuPont believes this information to be reliable and accurate. The information may be subject to revision as additional experience and knowledge is gained. It is the user s responsibility to determine the proper construction materials needed. For complete warranty information please call Tyvek. This information is not intended to be used by others for advertising, promotion, or other publication for commercial purposes. For more information about DuPont Weatherization Systems, please call Tyvek or visit us at opyright 2012 E.I. du Pont de Nemours and ompany. ll rights reserved. The DuPont Oval Logo, DuPont, Tyvek, ommercialwrap, FlexWrap, and StraightFlash are registered trademarks or trademarks of DuPont or its affiliates. ll rights reserved. K /12

Flashing Installation Guidelines Using DuPont Tyvek Fluid Applied Flashing-Brush Formulation

Flashing Installation Guidelines Using DuPont Tyvek Fluid Applied Flashing-Brush Formulation StraightFlash VF StraightFlash Tyvek Fluid pplied Flashing rush Formulation Flashing Installation Guidelines Using Tyvek Fluid pplied Flashing-rush Formulation Integral Flanged Window In Recessed Opening

More information

Flashing Installation Guidelines Using DuPont Tyvek Fluid Applied Flashing-Brush Formulation

Flashing Installation Guidelines Using DuPont Tyvek Fluid Applied Flashing-Brush Formulation StraightFlash VF StraightFlash Tyvek Fluid pplied Flashing rush Formulation Flashing Installation Guidelines Using Tyvek Fluid pplied Flashing-rush Formulation INTEGRL FLNGED WINDOW IN RECESSED OPENING

More information

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Flashing Systems Commercial Installation Guidelines DuPont DuPont Flashing Systems Commercial Installation Guidelines FOR DUPONT THRU-WALL FLASHING SHELF ANGLE Table of Contents Applicable Products... 2 Required Materials... 2 Optional Materials... 3 DuPont

More information

DUPONT TYVEK FLUID APPLIED WB+ WALL AND SUBSTRATE GUIDELINES METHODS FOR SUPERIOR PROTECTION AGAINST AIR AND WATER INTRUSION

DUPONT TYVEK FLUID APPLIED WB+ WALL AND SUBSTRATE GUIDELINES METHODS FOR SUPERIOR PROTECTION AGAINST AIR AND WATER INTRUSION upont Tyvek Fluid pplied W+ upont Tyvek Fluid pplied Flashing and Joint Compound+ UPONT TYVEK FLUI PPLIE W+ WLL N SUSTRTE GUIELINES METHOS FOR SUPERIOR PROTECTION GINST IR N WTER INTRUSION upont Tyvek

More information

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Flashing Systems Commercial Installation Guidelines DuPont DuPont Flashing Systems Commercial Installation Guidelines FOR STOREFRONT WINDOW ON SLAB AFTER WRB IS INSTALLED Table of Contents Applicable Products... 2 Recommended Materials... 2 Optional Materials...

More information

DUPONT TYVEK MECHANICALLY FASTENED AIR AND WATER BARRIER INSTALLATION GUIDELINES FOR BUILDINGS GREATER THAN 4 STORIES AND HIGH PERFORMANCE

DUPONT TYVEK MECHANICALLY FASTENED AIR AND WATER BARRIER INSTALLATION GUIDELINES FOR BUILDINGS GREATER THAN 4 STORIES AND HIGH PERFORMANCE DUPONT TYVEK MECHANICALLY FASTENED AIR AND WATER BARRIER INSTALLATION GUIDELINES FOR BUILDINGS GREATER THAN 4 STORIES AND HIGH PERFORMANCE INSTALLATIONS OF ANY HEIGHT REVISION 6/18 Table of Contents Note...

More information

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version DuPont Tyvek Sheathing Membrane Installation Guidelines Helping you get the job done right Canadian Version Version 2 Table of Contents Applicable Products...2 Required Materials...2 Code Requirements...3

More information

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2 DuPont Tyvek Air Barrier Installation Guidelines Helping you get the job done right Canadian Version Version 2 Table of Contents Applicable Products...2 Required Materials...2 Code Requirements...3 General

More information

Product and System Specifications DuPont Flashing Systems

Product and System Specifications DuPont Flashing Systems DuPont Building Innovations March 2007 4417 Lancaster Pike Chestnut Run Plaza 721 Wilmington, DE 19805 1-800-448-9835 www.construction.tyvek.com Product and System Specifications DuPont Flashing Systems

More information

DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines

DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines FOR OPEN STUD CONSTRUCTION FOR BUILDINGS LESS THAN 5 STORIES

More information

DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines

DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water-Resistive and Air Barriers Installation Guidelines DuPont Tyvek Water- Resistive and Air Barriers Installation Guidelines FOR OPEN STUD CONSTRUCTION FOR BUILDINGS LESS THAN 5 STORIES

More information

Guide Specification for the OSI QUAD Window and Door Flashing System

Guide Specification for the OSI QUAD Window and Door Flashing System Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification

More information

DuPont Tyvek Wall Underlay Install Guide

DuPont Tyvek Wall Underlay Install Guide DuPont Tyvek Wall Underlay Install Guide (For Residential & Light Commercial Buildings) Acceptable Solution to NZBC E2/AS1 New Zealand As at 1/4/15 Version 2 Subject to change without notice DuPont Tyvek

More information

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS USER S BULLETIN MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS CONTENTS Introduction...1 Use of this Residential Multi-Family User s Bulletin...1 DuPont Multi-Family

More information

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's

More information

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's

More information

BEP Blue Barrier Installation and Application Guide

BEP Blue Barrier Installation and Application Guide BEP Blue Barrier Installation and Application Guide BEP Blue Barrier is a system of seamless fluid applied products designed to protect the building envelope. Approved assemblies and applications listed

More information

BEP Blue Barrier Installation and Application Guide

BEP Blue Barrier Installation and Application Guide BEP Blue Barrier Installation and Application Guide BEP Blue Barrier is a system of seamless fluid applied products designed to protect the building envelope. Approved assemblies and applications listed

More information

A. Section includes fluid applied, vapor permeable membrane air barriers.

A. Section includes fluid applied, vapor permeable membrane air barriers. Master Construction Specifications Insert Project Name SECTION 072726 FLUID APPLIED MEMBRANE AIR BARRIERS PART 1 GENERAL 1.1 SUMMARY A. Section includes fluid applied, vapor permeable membrane air barriers.

More information

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS CHECKLIST PRIOR TO THE INSTALLATION OF BACKSTOP NT - SMOOTH AND TEXTURE Project Conditions Maximum storage

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

Perm-A-Barrier VPS (Vapor Permeable Sheet)

Perm-A-Barrier VPS (Vapor Permeable Sheet) VPS (Vapor Permeable Sheet) Self-adhering vapor permeable air barrier membrane Product Description VPS (Vapor Permeable Sheet) is a vapor permeable air barrier membrane consisting of a proprietary breathable

More information

Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Application Instructions

Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS Application Instructions Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier Backstop NT For Use Beneath Claddings Other Than

More information

BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier. Backstop NT - Texture Application Instructions

BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier. Backstop NT - Texture Application Instructions BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier Backstop NT - Texture Application Instructions CHECKLIST PRIOR TO THE INSTALLATION OF BACKSTOP NT TEXTURE

More information

NOVAWRAP ASPIRE Q & A

NOVAWRAP ASPIRE Q & A TM NOVAWRAP ASPIRE i build with What is building wrap and why should I use NovaWrap Aspire? A building wrap like NovaWrap Aspire is a critical element in the building envelope system which is the physical

More information

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION SECTION 072700 VAPOR PERMEABLE AIR BARRIER LIQUID MEMBRANE PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. The Work of this Section, as shown or specified, shall be in accordance with the requirements of the

More information

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of

More information

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS USER S BULLETIN SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS CONTENTS Introduction...1 Use of This Residential Single Family User s Bulletin...1 DuPont Residential

More information

DUPONT TYVEK COMMERCIAL SOLUTIONS

DUPONT TYVEK COMMERCIAL SOLUTIONS BUILDING SCIENCE BULLETIN DUPONT TYVEK COMMERCIAL SOLUTIONS DUPONT TYVEK COMMERCIAL AIR BARRIER ASSEMBLIES EXCEED AIR BARRIER ASSOCIATION OF AMERICA, ASHRAE 90.1 AND IECC AIR LEAKAGE REQUIREMENTS WHEN

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2045 Reissued 01/2017 This report is subject to renewal 01/2019. DIVISION: 07 00

More information

SECTION FLUID APPLIED VAPOR PERMEABLE AIR BARRIER MEMBRANE

SECTION FLUID APPLIED VAPOR PERMEABLE AIR BARRIER MEMBRANE SECTION 07 27 26.01 FLUID APPLIED VAPOR PERMEABLE AIR BARRIER MEMBRANE SIKA SPECIFICATION NOTE: This guide specification includes test methods, materials and installation procedures for an air barrier

More information

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all labor, materials and equipment

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

Keene Building Products

Keene Building Products Keene Building Products Keene Building Products is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported

More information

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013) SECTION 07 27 20 FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013) PART 1 GENERAL 1.01 SECTION INCLUDES A. Materials and installation methods supplementing a one-component

More information

application instructions

application instructions application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

Application Instructions

Application Instructions Application Instructions 3.01 INSPECTION A. Prior to the application of Master Wall Inc. Cemplaster Fiberstucco, the substrate shall be examined for compliance with the contract documents and Master Wall

More information

Perm-A-Barrier NPS (Non Permeable Sheet)

Perm-A-Barrier NPS (Non Permeable Sheet) NPS (Non Permeable Sheet) Primer-less self-adhered air & vapor barrier membrane Product Description NPS Wall Membranes are ideal for protecting the building superstructure from the damaging effects of

More information

AVM System 500. Aussie Membrane 500

AVM System 500. Aussie Membrane 500 Generic Spec TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing

More information

AVM System 500. Aussie Membrane 500

AVM System 500. Aussie Membrane 500 Generic Spec TECH DATA SHEET Sections - 071000 / 071400 / 071416 ICC ESR-2503 L.A. RR#: 25550 Heavy Duty Below Grade Bituminous Waterproofing Membrane Sections 071000 / 071400 / 071416 Fluid Applied Waterproofing

More information

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers.

OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers. OCS ONE COAT STUCCO A custom blend of Portland cement, sand, extenders, fiber reinforcement and modifiers. Designed to save material by functioning as an exterior cladding in thicknesses ranging from 3/8

More information

SECTION SELF-ADHERING SHEET FLASHING

SECTION SELF-ADHERING SHEET FLASHING MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP

More information

Data Sheet Eco-Smart Membrane WS M1

Data Sheet Eco-Smart Membrane WS M1 Water-based Acrylic WS M1 Elastomeric Waterproofing Membrane is a durable, multi-use, extremely durable acrylic coating. At an ideal wet film thickness of 10-14 mils per coat (8-10 mils dry film finish

More information

Inspection Fundamentals: Stucco & EIFS

Inspection Fundamentals: Stucco & EIFS Inspection Fundamentals: Stucco & EIFS By Ben Gromicko To be able to identify the stucco system you must understand system components. You should understand the basic components of the most common stucco

More information

BACKSTOP NT - VB A high performance, non-cementitious water-resistive membrane and air/vapour barrier

BACKSTOP NT - VB A high performance, non-cementitious water-resistive membrane and air/vapour barrier A high performance, non-cementitious water-resistive membrane and air/vapour barrier Backstop NT - VB Application Instructions for use behind Dryvit EIFS A high performance, non-cementitious water-resistive

More information

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE SIDER-CRETE, INC. 153 Regur Road Hawkinsville, GA 31036 USA Ph: 478.892.9800 www.sider-crete.com MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

More information

Blue Barrier Flash N Wrap 2400

Blue Barrier Flash N Wrap 2400 Tools/Materials Needed 2 or 5 gal pail of Poly Wall Blue Barrier Flash N Wrap 2400 10.1 oz caulking or 20 oz. sausage tube of Poly Wall Blue Barrier 2200 Joint Filler Caulking (cartridge or sausage) gun

More information

Pol-E-Base Modified Bitumen Roof System

Pol-E-Base Modified Bitumen Roof System Pol-E-Base Modified Bitumen Roof System Specification Chemicals, Inc. produces the Pol-E-Base Built-up Roofing System as the ultimate in field applied reflective insulation roofing. It has the advantages

More information

APPLICATION INSTRUCTIONS REALSIDE TM

APPLICATION INSTRUCTIONS REALSIDE TM APPLICATION INSTRUCTIONS REALSIDE TM GENERAL INFORMATION: RealSide is a natural, real wood siding product designed for use in exterior cladding applications. RealSide is manufactured from hand selected,

More information

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM SIDER-CRETE, INC. 153 Regur Road Hawkinsville, GA 31036 USA Ph: 478.892.9800 www.sider-crete.com SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO

More information

XTREME-BOND INSTALLATION SYSTEM

XTREME-BOND INSTALLATION SYSTEM XTREME-BOND FOR THIN-STONE VENEER Weather-resistant resistant Superior bonding & flexural strengths Exceptional sag resistance Meets requirements of Type S mortar Pre-blended for quality consistency from

More information

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY SOLAR COATING SYSTEMS ACRYLIC ROOF RENOVATION 4.5 Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY NAME ADDRESS A. Furnish and install a seamless, waterproof spray applied elastomeric

More information

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION MANUFACTURER S GUIDE SPECIFICATIONS SECTION 04 27 23 REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 07.09.13 Carlisle and R2+ are trademarks

More information

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Lap Siding, e.g. Fiber Cement and Wood/Cedar

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Lap Siding, e.g. Fiber Cement and Wood/Cedar DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Lap Siding, e.g. Fiber Cement and Wood/Cedar VERSION 08/14 Table of Contents Applicable Products... 2

More information

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane PERM-A-BARRIER VPS Self-adhering vapor permeable air and water barrier membrane Product Description GCP Applied Technologies ( GCP ) PERM-A-BARRIER VPS (Vapor Permeable Sheet) membrane is a vapor permeable

More information

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas. SPECIFICATION FOR PROTECTO WRAP AFM-WM FOR INTERNAL WET AREAS BRANZ Appraisal Certificate # 461 (2010) Internal wet areas AFM/WM INTERNAL 0104 Page 1 AFM-WM INTERNAL SPECIFICATION PRODUCT DESCRIPTION Anti

More information

Installation Procedures for the Ultra Air Barrier Wall System

Installation Procedures for the Ultra Air Barrier Wall System STEEL STUD BACKUP CONSTRUCTION Installation Procedures for the Ultra Air Barrier Wall System Installation Procedures for the Ultra Air Barrier Wall System in Steel Stud Backup 1 System Overview STYROFOAM

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

BENJAMIN OBDYKE INCORPORATED

BENJAMIN OBDYKE INCORPORATED SLICKER CLASSIC OR SLICKER MAX PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Rainscreen for Use in Sidewall Construction. Specifier Note: Revise paragraph below to suit project requirements. If a reader

More information

FirstEnergy Program Overview

FirstEnergy Program Overview FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio

More information

PROCOR Composite Waterproofing System

PROCOR Composite Waterproofing System PROCOR Composite Waterproofing System Fluid-applied and sheet waterproofing system Product Description PROCOR Composite Waterproofing System, combining PROCOR 75 fluid-applied membrane with PROCOR Composite

More information

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE SECTION 07 27 26 VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE This guide specification has been prepared by Polyguard Products Inc., in electronic and printed media, as an aid to specifiers in preparing

More information

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS VAPROLIQUI-FLASH Liquid Applied Waterproof Flashing Material OVERVIEW VaproLiqui-Flash is a liquid applied Waterproof Flashing material for window and door rough opening interfaces. It is designed for

More information

Blue Barrier Liquid Wrap 2300

Blue Barrier Liquid Wrap 2300 Tools/Materials Needed 5 gal pail of PolyWall Blue Barrier Liquid Wrap 2300 10.1 oz Caulking Tube of Poly Wall Blue Barrier 2200 Joint Filler Caulking gun 9 to 11-inch Hot Dog Style Roller handle and Mini

More information

Air and Vapor Barrier 3015

Air and Vapor Barrier 3015 Air and Vapor Barrier 3015 Technical Data March 2017 Product Description 3M Air and Vapor Barrier 3015 is an air, moisture and water impermeable membrane with an aggressive, high-tack acrylic pressure

More information

FireShield Restoration Specifications - EPDM

FireShield Restoration Specifications - EPDM FireShield Restoration Specifications - EPDM Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FIRESHIELD Restoration Specifications EPDM PART 1 GENERAL

More information

THE BRITE THING TO DO

THE BRITE THING TO DO REDUCING ENERGY CONSUMPTION IMPROVING AIR QUALITY THE BRITE THING TO DO BRITE-n-EZ Enhanced Coating Application Process on Black EPDM Roof Membrane BRITE-n-EZ EPDM Application Instructions CLEANING Remove

More information

Master-Seal Surface-Applied Waterproofing System

Master-Seal Surface-Applied Waterproofing System P 1/7 INDUSTRIAL ROOFING, INC. Master-Seal Surface-Applied Waterproofing System Master-Seal is a highly effective waterproofing system designed to seal surfaces from water seepage in roofs with minimum

More information

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013) SECTION 07 27 20 FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013) PART 1 GENERAL 1.01 SECTION INCLUDES A. Materials and installation methods supplementing a one-component

More information

TABLE OF CONTENTS IMPORTANT INFORMATION. INSTALLATION GUIDELINES Revised 5/5/2017 REFERENCES...2

TABLE OF CONTENTS IMPORTANT INFORMATION. INSTALLATION GUIDELINES Revised 5/5/2017 REFERENCES...2 TABLE OF CONTENTS REFERENCES...2 PROJECT PLANNING...2 Verify Site Conditions...2 Building Code Requirements...2 Estimating Quantities Needed...2 SURFACE PREPARATION...3-5 Weather Resistive Barrier...3-4

More information

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate Colphene BSW Training and Application Guide Colphene BSW Waterproofing Membrane. 1. Prepare substrate Substrate must be structurally sound. Surface must be free of voids, spalled areas, loose aggregate,

More information

BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier

BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier Backstop NT - Texture Specifications DRYVIT SYSTEMS CANADA MANUFACTURER S SPECIFICATION SECTION 07240 BACKSTOP NT -

More information

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3966 Reissued 07/2017 This report is subject to renewal 07/2019. DIVISION: 07 00

More information

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration DS497 SECTION ONE A. Objective The objective of this guide is to provide owners and general contractors/construction

More information

WEIGHT PER PIECE (LBS.)

WEIGHT PER PIECE (LBS.) PRODUCT DESCRIPTION DATA SHEET 04 73 19-US BASIC USE ProGUARD DP is intended to be installed over sheathing and waterproofing over steel or wood studs or over concrete masonry units or poured concrete

More information

Product Brochure. Masonry Drainage and Ventilation Products

Product Brochure. Masonry Drainage and Ventilation Products Product Brochure Masonry Drainage and Ventilation Products Every building professional who works with masonry knows the #1 reason masonry buildings fail is moisture trapped behind the veneer. Professionals

More information

SECTION FLUID-APPLIED WEATHER AND AIR BARRIER SYSTEM FOR VENTILATED CAVITY

SECTION FLUID-APPLIED WEATHER AND AIR BARRIER SYSTEM FOR VENTILATED CAVITY SECTION 07 27 27 FLUID-APPLIED WEATHER AND AIR BARRIER SYSTEM FOR VENTILATED CAVITY SPECIFIER NOTE: THIS SECTION IS INTENDED FOR A COMPLETE BUILDING ENVELOPE BARRIER APPLICATION, INCLUDING VENTILLATED

More information

EDGEWATER, FLORIDA JUNE 14, 2010

EDGEWATER, FLORIDA JUNE 14, 2010 SECTION 09 2422 - STO QUIK GOLD SOFFIT SYSTEM PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION FLUID-APPLIED AIR & WATER-RESISTIVE BARRIER SYSTEM FOR NEW CONSTRUCTION

SECTION FLUID-APPLIED AIR & WATER-RESISTIVE BARRIER SYSTEM FOR NEW CONSTRUCTION PART 1 - GENERAL 1.1 SUMMARY: SECTION 07 27 26 FLUID-APPLIED AIR & WATER-RESISTIVE BARRIER SYSTEM FOR NEW CONSTRUCTION A. Work of this section includes window and door flashing, air and water-resistive

More information

SRP-AirOutshield UV Issued:

SRP-AirOutshield UV Issued: SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing

More information

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2000 Reissued 02/2017 This report is subject to renewal 02/2019. DIVISION: 07 00 00 THERMAL

More information

Enviro-Dri Weather-Resistant Barrier (WRB) System Installation Instructions Revised

Enviro-Dri Weather-Resistant Barrier (WRB) System Installation Instructions Revised Enviro-Dri Weather-Resistant Barrier (WRB) System Installation Instructions Revised 02.12.10 General: The purpose of the Enviro-Dri Weather Resistant Barrier (WRB) System, by Tremco Barrier Solutions Inc.,

More information

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3310 Reissued 07/2018 This report is subject to renewal 07/2020. DIVISION: 07 00

More information

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE PART 1 - GENERAL 1.1 SUMMARY SECTION 07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit

More information

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION STUC-O-FLEX RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION 09 97 23 PART 1-GENERAL 1.00 SCOPE: Manufacturer's specifications containing the requirements necessary

More information

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY SOLAR COATING SYSTEMS 2-PLY EMULSION MULSION/A /ACRYLIC SYSTEM Specification for Built-Up Roofing 07590 PART 1. GENERAL 1.01 SUMMARY Name Address City, State, zip A. Furnish and install a seamless, reinforced

More information

Installation Guide Wall Panels

Installation Guide Wall Panels Installation Guide Wall Panels Jointless or Dry-Stacked Installation (Read Prior to installation) The MStone system is a jointless / dry-stacked installation where panels and corners fit tightly together

More information

Installation Guidelines

Installation Guidelines Installation Guidelines The Vertibreak Wall System: Installation Guidelines Rainscreen Insulation for New or Retrofit Construction Applications Vertibreak rainscreen insulation is an expanded polystyrene

More information

SECTION Fiber Reinforced Stucco 1

SECTION Fiber Reinforced Stucco 1 CSI SECTION 09200 FIBER REINFORCED STUCCO PART 1 GENERAL 1.01 SUMMARY A. Section Description: Provided lath and plaster where shown on the Drawings, as specified herein, and as needed for complete and

More information

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER PART 1 - GENERAL 1.01 SUMMARY SECTION 07 65 00 FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER A. Section includes through wall masonry flashing system components for installation over sheathing where spray

More information

LP SmartSide Perfection Shingle

LP SmartSide Perfection Shingle Application Instructions Fiber Substrate Lap Siding A A - Lap Siding ON SITE STORAGE Store off the ground well supported, on a flat well-drained surface. (Diagram 1a) Additional support may be required

More information

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE Page 1 of 8 MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE SOPRASEAL STICK 1100 T FOR A COMPLETE DESCRIPTION OF PRODUCTS AND APPLICABLE STANDARDS, PLEASE REFER TO THE TECHNICAL DATA SHEETS

More information

StoGuard Air Barrier Installation Manual

StoGuard Air Barrier Installation Manual StoGuard Air Barrier Installation Manual 1. The importance of air barriers p. 2 2. Essential background p. 3-4 Components of an air barrier system Planes of protection in a wall system Third party quality

More information

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General EVALUATION SUBJECT: QUADFOAM NATURESEAL 500 REPORT HOLDER: Accella Polyurethane Systems 100 Enterprise Drive Cartersville, GA 30120 (770) 607-0755 CSI Division: 07 00 00 THERMAL AND MOISTURE PROTECTION

More information

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General EVALUATION SUBJECT: QUADFOAM NATURESEAL 500 REPORT HOLDER: Accella Polyurethane Systems 100 Enterprise Drive Cartersville, GA 30120 (770) 607-0755 CSI Division: 07 00 00 THERMAL AND MOISTURE PROTECTION

More information

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018 EVALUATION SUBJECT: FOAMSULATE 50-NIB SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION REPORT HOLDER: Accella Polyurethane Systems 100 Enterprise Drive Cartersville, GA 30120 (770) 607-0755 CSI Division:

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.

More information

Self Adhesive EPDM TRAINING MANUAL

Self Adhesive EPDM TRAINING MANUAL Self Adhesive EPDM TRAINING MANUAL Rubber4Roofs Ltd, Unit 4 Kingswood Close Page 1 of 7 Copyright Rubber4Roofs Ltd GeneralHealth&Safety Extreme care must be exercised when working on ladders, roofs, below

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include: