UNIVERSITY OF CALIFORNIA, SAN DIEGO

Size: px
Start display at page:

Download "UNIVERSITY OF CALIFORNIA, SAN DIEGO"

Transcription

1 UNIVERSITY OF CALIFORNIA, SAN DIEGO BERKELEY DAVIS 1R VINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SANTA BARBARA SANTA CRUZ OFFICE OF THE ASSOCIATE VICE CHANCELLOR CAMPUS ARCHITECT- FACILITIES DESIGN & TEL: (858) FAX: (858) GILMAN DRIVE #0916 LA JOLLA, CALIFORNIA November 15, 2013 TO: ALL HOLDERS OF BIDDING DOCUMENTS RADIOLOGY ROOM #2 REMODEL UCSD MEDICAL CENTER - HILLCREST UNIVERSITY OF CALIFORNIA, SAN DIEGO Project No.: 4631/A4S-002/ Enclosed is the following: l. Addendum No.2 dated November 15,2013, to the Construction Documents. 2. Office of Statewide Health Planning and Development's Testing, Inspection and Observation Program. 3. Revised drawing P-100 (signed). PLEASE NOTE: BID DATE REMAINS THURSDAY, NOVEMBER 21,2013, AT 2:00P.M. Sincerely, ~tl tni/f0ji6 James. Gillie Senio Director of Construction Serv es ities Design and Construction Enclosures

2 RADIOLOGY ROOM #2 REMODEL UCSD MEDICAL CENTER- HILLCREST UNIVERSITY OF CALIFORNIA, SAN DIEGO Project No.: 4631/A4S-002/ General: ADDENDUM NO. TWO TO THE DOCUMENTS NOVEMBER 15, 2013 The following changes, additions, or deletions shall be made to the following documents; all other conditions shall remain the same. I. CLARIFICATIONS Item# 1. Question: The materials included in spec section sheet vinyl floor coverings are Mannington commercial and Toli "Mature" woods, neither of which are used on this project. The materials used on this project are Forbo Marmoleum "Real" linoleum and Armstrong Timberline" sheet vinyl. Will specifications be issued to cover these materials? Answer: Mannington and Toli products currently listed in spec section are incorrect. Forbo Marmoleum and Armstrong Timberline items specified on the drawings are the correct products. 2. Question: Both the Forbo linoleum and the Armstrong sheet vinyl will receive heat welded seams. There will be one seam which cannot be welded. This is the seam between the linoleum and the sheet vinyl. The linoleum rod will not bond to the sheet vinyl and the sheet vinyl weld rod will not bond to this linoleum. Please advise how to address this seam. Answer: Per Forbo, the linoleum weld rod will bond to sheet vinyl products with Marmoweld welding rod. 3. Question: Is there a specification for the existing flooring which will need to patch in? Answer: Existing flooring in (E) Waiting Area is Marmoleum Real and Fresca. Remove flooring in its entirety in lieu of patching. New flooring to match existing product, style and pattern. 4. Question: Sheet A-602 indicates a Privacy Curtain specification FBR-2 under the finish specifications. The finish schedule room Radiology Exam Room 2 under remarks references FBR-2. Please clarify in plan view where the Privacy Curtain is to be located. Answer: FBR-2: Privacy Curtain is no longer included in project. 5. Question: Detail 23/A-521 callout in room 1-506A on the Renovation Reflected Ceiling Plan on sheet A-102 references a Unistrut@ Partition- Parallel detail. Answer: Incorrect detail reference. Refer to detaii7/a-511. UCSD- FD&C Page 1 of 1

3 2/15

4 OFFICE OF STATEWIDE ALTH PLAMNING AND DEVELOPIVIENT FACILITIES DEVELOPIVIENT DiVISIOM R Street, Suite 200 ~ Sacramento, California 9581 I Phone (916) ftvp 700 N. Alameda Street, Suite ~ Los Angeles, California Phone (213) OCT 0 8 mi ENTEREi Testing, Inspection and Observation Program 2010 California Building Standards Code - OSHPD 1 This program is prepared and submitted for an OSHPD I project. OSHPD 1 projects include alt construction and remodel projects for general acute-care hospitals and acute psychiatric hospitals. OSHPD 1 projects also include construction and remodel of stalled nursing facilities and/or intermediate care facilities except those of single-stoiy, Type V, wood or light steel-frame construction. A Facility*: "acilily Name: UCSD Medical Center - Hillcrest Project*: P Street Address: 200 W. Arbor Drive Sub #: City: San Diego County: San Diego Record Name (Scope of Project): Radiology Room 2 TESTS - DOCUMENTATION / CERTIFICATION REQUIRED STRUCTURAL TESTS Compact fill CBC 1704A.7 Filled material acceptance test Compact fill CBC 1704A.7& J Compaction test Soil and rock anchors CBC 1811A&J106.2 Load test Deep foundation elements CBC 1810A , 181 OA , & 1810A Load test CBC 1704A.4.1, 1916A.1, ACI & 3.2 Cementitous materials CBC 1704A.4.1, ACI & Aggregates/Reactive aggregates CBC1704A.4.1, ACI & 3.4 Water CBC 1704A.4.1, ACI & 3.6 Admixtures CBC1704A.4.1, 1904A, & 1905A.1 to 1905A.5 Mix design CBC 1704A.4.1 & 1905A.6 Strength test CBC 1704A.4.1, 1916A.2, & ACI Metal reinforcement (including welded wire fabric) CBC 1704A.4. I & ACI Headed studs and headed stud assemblies CBC 1704A.4.1, 1916A.3& ACI Prestressing tendons and anchorage Shotcrete CBC 1913A.5 Preconstruction test VERIFICATION OFFICE USE ONLY Shotcrete CBC 1913A.10 Strength test NOTE: To Be Determined (TBD) - The name of the firm or individual to perform this test or special inspection shall be submitted to and approved by the Office, prior to proceeding with the work that requires this test or special inspection. OSH-FD-303A (Rev 03/11) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page I of 11

5 In! OFFICE OF STATEWIDE.ALTH PLANNING ANO DEVELQPMEN1 FACILITIES DEVELOPMENT DIVISION R Street, Suite Sacramento, California Phone (916) N. Alameda Street, Suite ~ Los Angeles, California Phone (213) Testing, inspection and Observation Program 2010 California Building Standards Code - OSHPD 1 Facility #: Facility Name: UCSD Medical Center - Hillcrest Project #: P Sub #: 13 TESTS - DOCUMENTATION / CERTIFICATION REQUIRED CVER1FICAT}ON N OFFICE USE ONLY STRUCTURAL TESTS Shotcrete CBC 1704A.17.1 Core test Post-installed anchors CBC 1916A.7 X Installation verification test CBC 2105A , ACI , & ACI Material standards tests CBC 2105A & 2103A.8 Mortar test CBC 2105A Grout test CBC2103A.14 Additives and admixtures CBC 2105A.4 Core test CBC2105A.2.2 Compressive strength f' m test CBC 2203A.1 Structural steel and cold formed steel X CBC 2212A.1 & 1708A.3 High strength bolts, nuts, and washers X CBC 2212A.2& 1708A.3 End-welded studs CBC 2205A.4.3 & 1708A.3 Buckling restrained brace (Load test) CBC 1708A.3 Nondestructive weld test CBC 2212A.4.2& 1708A.3 Beam to column moment connections Miscellaneous CBC Veneer bond strength test Equipment and components CBC 1708A.4 Special Seismic Certification Isolators CBC 1708A.5 Prototype and production test Dampers CBC 1708A.5 Prototype and production test * NOTE: To Be Determined (TBD) - The name of tho firm or individual to perform this test or special inspection shall be submitled to and approved by the Office, prior to proceeding with the work that requires this test or special inspection. OSH-FD-303A (Rev 03/1 I) STATE OF CALIFORNIA - HEALTH AMD HUMAN SERVICES AGENCY Page 2 of 11

6 . f]!,, OFFICE OF STATEWIDE WlfALTH PLANNING AMD DEVELOP! =N1 rvi C.; f i -i! '!''$' FACILITIES DEVELOPMENT DIVISION - "'j'.v 400 R Street, Suite 200 ~ Sacramento, California Phone (916) WM- 700 N. Alameda Street, Suite Los Angeles, California Phone (213) JL Testing, Inspection and Observation Program 2010 California Building Standards Code - OSHPD Facility*: B Facility Name: UCSD Medical Center - l-lillcrest^ TESTS - DOCUMENTATION / CERTIFICATION REQUIRED STRUCTURAL TESTS Structural Design Criteria CBC Tests to support alternative system ELECTRICAL TESTS Ground fault protection CEC (C) & (D) Performance test Emergency generator tests CEC 700.4(A) & NFPA MECHANICAL TESTS Listed hood assemblies CMC Grease removal devices in hoods CMC Commercial kitchen hood ventilation CMC Performance test Refrigeration equipment CMC Refrigeration detection and alarm system CMC & CFC Refrigeration flaring system CMC Safety and effectiveness Steam and hot water boilers CMC & Hydronics CMC Pressure test of steam and water piping Hydronic panel heating system CMC Testing Project #: P VERIFICATION Sub #: OFFICE USE ONLY Process piping CMC Pressure test Ventilation system CMC & Table 4-A Areas tested and balanced Airborne Infection Isolation Rooms and Protective Environment Rooms CMC Alarm system test Airborne Infection Isolation Rooms and Protective Environment Rooms CMC Mechanical system tested and balanced TioTETf obe DeteTmhTedTjBb) - the name of the firm or individual to perform"this test or special inspection shall be submitted to and approved by the Office, prior to proceeding with tho work that requir es tliis test or special inspection. OSH-FD-303A (Rev 03/11) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page 3 of 11

7 01 OFFICE OF STATEWIDE DEALTH PLANNING AND DEVELOPMENT?^ FACILITIES DEVELOPMENT DIVISION R Street, Suite 200 ~ Sacramento, California Phone (916) N. Alameda Street, Suite ~ Los Angeles, California Phone (213) resting, flnspe ctlon and Observa' :ion Program 2010 California B Liilclinq Standards Code - OSHPD T i Facility*: Facility Name: UCSD Medical Center - Hillcrest Project #: P Sub #: B TESTS - DOCUMENTATION / CERTIFICATION REQUIRED FIRE PROTECTION EQUIPMENT TESTS VERIFICATION Fire alarm CFC 901.5, CBC 907.7, & NFPA Acceptance and reacceptance testing x Fire and smoke dampers CFC & CBC X Duct detectors CFC & NFPA Differential pressure test Smoke control system CFC & CBC Fire sprinkler CFC & NFPA Chapter 24 - Aboveground piping Fire sprinkler CFC & NFPA Chapter 24 - Underground piping Standpipe system CFC & NFPA Chapter 11 Acceptance testinq - Aboveground piping Standpipe system CFC & NFPA Chapter 11 - Underground piping Private fire mains CFC & NFPA Fire pumps CFC & NFPA & 14.2 Acceptance testinq Wet chemical extinguishing system CFC & NFPA 17A Clean agent extinguishing system CFC & NFPA C0 2 extinguishing system CFC & NFPA & Acceptance testinq Dry chemical extinguishing system CFC & NFPA Halon 1301 extinguishing system CFC & NFPA 12A OTHER TESTS Polarity Test, CECE (B) X OFFICE USE ONLY Underground fuel storage tank CFC & NFPA Tightness testing NOTE: To Be Determined (TBD) - The name of the firm or individual to perform this test or special inspection shall be submitted to and approved by the Office, prior to proceeding with the work that requires this test or special inspection. i OSH-FD-303A (Rev 03/11) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page 5 of 11

8 1\ OFFICE OF STATEWIDE ALT I-I PLANNING AND DEVELOP MEN! FACILITIES DEVELOPMENT DIVISION - lilj'l'til R s ' r e e t. Suite 200 ~ Sacramento, California Phone (916) N. Alameda Street, Suite Los Angeles, California Phone (213) ana'i it il inspection and unservavio Pi 'ooii"a[iiii 2010 California Bui ing Standards Code - OSHPD Facility*: Facility Name: UCSD Medical Center Hillcrest Project #: P SPECIAL INSPECTIONS - DOCUMENTATION / CERTIFICATION REQUIRED STRUCTURAL INSPECTIONS Alternative system CBC1704A.15 Construction materials and methods for alternative system Shoring CBC J106.2 Shoring Mechanical and electrical components CBC 1707A.7 Anchorage, Bracing, and Vibration Isolators Designated seismic system CBC1707A.8 Special Seismic Certification label and anchorage or mounting Seismic isolation and damping system CBC 1707A.9 Fabrication, installation, prototype, and production testing Aluminum CBC Inspection VERIFICATION RESPONSIBLE MECHANICAL INSPECTIONS RESPONSIBLE TBD Visually inspect filter banks for torn media and bypass filter frames CMC Process piping CMC Installation PLUMBING INSPECTIONS RESPONSIBLE Fuel piping CPC Medical gas NFPA Chapter 5 Brazing and labeling of systems FIRE PROTECTION INSPECTIONS RESPONSIBLE Fire resistive materials CBC1704A.12 Spray-applied fireproofing Smoke control systems CBC 1704A.16 Ductwork and operation Sprinkler system piping CFC & NFPA Welded pipe and fittings [OR Sub #: OFFICE USE ONLY Standpipe system piping CFC & NFPA : Welded pjpejand fittings NOTE: To Be Determined (TBD) - The name of the firm or individual to perform this test or special inspection shall be submitted to and approved by the Office, prior to proceeding with the work that requires this test or special inspection. OSH-FD-303A (Rev 03/TI) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page 8 of 11

9 tv OFFICE OF STATEWIDE \LTH PLANNING AND DEVELOPMENT ^ FACILITIES DEVELOPMENT DIVISION R Street, Suite 200 ~ Sacramento, California N. Alameda Street, Suite ~ Los Angeles, California Phone (916) Phone (213) Testing, Inspection and Observation Program 2010 California Building Standards Code - OSHPD 1 r acility#: Facility Name: UCSD Medical Center Hillcrest Project #: P Sub #: SPECIAL INSPECTIONS - DOCUMENTATION / CERTIFICATION REQUIRED OTHER SPECIAL INSPECTIONS RESPONSIBLE VERIFICATION OFFICE USE ONLY Polarity Test CEC (b) TBD REQUIRED OBSERVATION (See "PERSONAL KNOWLEDGE" as defined in California Administrative Code, Section 7-151) OBSERVATION AND REPORTING VERIFIED COMPLIANCE REPORT REQUIRED AS INDICATED (Form OSH-FD-123) Ref. No. 'MILESTONES GEOR AOR SEOR MEOR EEOR CONT SP INSP FOR OFFICE USE ONLY OSHPD framing prior to ceiling installation X X FINAL VERIFIED COMPLIANCE REPORT AT COMPLETION X X X X X x! i * NOTE: Construction observation may be scheduled at project milestones, at specific intervals, or a combination of both. ABBREVIATIONS: Geotechnical Engineer of Record (GEOR), Architect of Record (AOR), Structural Engineer of Record (SEOR), Mechanical Engineer of Record (MEOR), Electrical Engineer of Record (EEOR), Contractor or Owner/Builder (CONT), Special Inspector (SP. INSP), and Inspector of Record (). OSH-FD-303A (Rev 03/11) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page 9 of 11

10 4W\t - OFFICE OF STATEWIDE ALTH PLANNING AND DEVELOP 1EN' FACILITIES DEVELOPMENT DIVISION R Street, Suite 200 ~ Sacramento, California N. Alameda Street, Suite Los Angeles, California Testing, Inspection and Observation Program 2010California Building Standards Code - OSHPD 1 Phone (916) Phone (213) Facility*: Facility Name: UCSD Medical Center - Hillcrest P Project #: Sub #: Ref. No. REQUIRED OBSERVATION (See "PERSONAL KNOWLEDGE" as defined in California Administrative Code, Section 7-151) 'INTERVALS OBSERVATION AND REPORTING GEOR VERIFIED COMPLIANCE REPORT REQUIRED AS INDICATED (Form OSH-FD-123) AOR SEOR /leor EEOR CONT SP INSP FOR OFFICE USE ONLY OSHPD FINAL VERIFIED COMPLIANCE REPORT AT COMPLETION X X X NOTE: Construction observation may be scheduled at project milestones, at specific intervals, or a combination of both. X ABBREVIATIONS: Geotechnical Engineer of Record (GEOR), Architect of Record (AOR), Structural Engineer of Record (SEOR) Mechanical Engineer of Record (MEOR), Electrical Engineer of Record (EEOR), Contractor or Owner/Builder (CONT), Special Inspector (SP INSP) and Inspector of Record (). OSH-FD-303A (Rev 03/11) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page 10 of 11

11 mm OFFICE OF STATEWIDE ALTH PLANNING AND DEVIELO FACILITIES DEVELOPIVIENT DIVISION R Street, Suite 200 ~ Sacramento, California Phone (916) N. Alameda Street, Suite ~ Los Angeles, California Phone (213) "estincj, Inspection and Observation Program P Facility*: Facility Name: UCSD Medical Center - Hillcrest Project #: Sub #: Samples of Test and Inspection Reports are: Attached To be provided following determination of the responsible firm(s) or individual(s). Samples shall be submitted to and approved by the Office, prior to proceeding with the work that requires tests or special inspections. Not applicable. Project has no required tests or special inspections. Required test and inspection reports shall be prepared and submitted to OSHPD/ within.. clays of the completion of all tests and inspections. If not designated, all reports shall be submitted to the Office within 15 calendar days. In addition to the preprinted tests and special inspections identified on this form, this program includes additional tests and special inspections as indicated: Other Tests Other Special Inspections See Attachment This program has been prepared and submitted for an OSHPD I project. OSI-IPD I projects include all construction and remodel projects for general acute care hospitals and acute psychiatric hospitals. OSHPD I projects also include construction and remodel of skilled nursing facilities and/or intermediate care facilities except those of single-story, Type/tQyvood or light sfeej-frame construction. Submitted by: I. Simon Warner C fi Architect/Engineer of Record (Print Name) Professional License %7 Architect/Engineer of Record (Signature) Date OSI-IPD Plan A r ^ ^ ^ j / ^ ^ FOR OFFICE USE ONLY OSHPD Field Acceptance: Name - Date Name Date /// ' i Date 4 (9 ' Date AC AC Mechanical Date AC Electrical At Fire and Li fe Safety 0 Date Date A AC AC Comments: MOTE: For Testing, Inspection and Observation Program Instructions, visit our website. OSH-FD-303A (Rev 03/11) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page 11 of Tl

Testing, Inspection and Observation Program 2013 California Building Standards Code OSHPD 1

Testing, Inspection and Observation Program 2013 California Building Standards Code OSHPD 1 OSH-FD-303A (Rev 08/12/14) STATE OF CALIFORNIA - HEALTH AND HUMAN SERVICES AGENCY Page 1 of 12 This program is prepared and submitted for an OSHPD 1 project. OSHPD 1 projects include all construction and

More information

12372 Tri-City Medical Center S

12372 Tri-City Medical Center S This program is prepared and submitted for an OSHPD 1 project. OSHPD 1 projects include all construction and remodel projects for general acute-care hospitals and acute psychiatric hospitals. OSHPD 1 projects

More information

12372 Tri-City Medical Center S

12372 Tri-City Medical Center S This program is prepared and submitted for an OSHPD 1 project. OSHPD 1 projects include all construction and remodel projects for general acute care hospitals and acute psychiatric hospitals. OSHPD 1 projects

More information

12372 Tri City Medical Center S

12372 Tri City Medical Center S This program is prepared and submitted for an OSHPD 1 project. OSHPD 1 projects include all construction and remodel projects for general acute-care hospitals and acute psychiatric hospitals. OSHPD 1 projects

More information

12372 Tri City Medical Center S

12372 Tri City Medical Center S This program is prepared and submitted for an OSHPD 1 project. OSHPD 1 projects include all construction and remodel projects for general acute-care hospitals and acute psychiatric hospitals. OSHPD 1 projects

More information

J~e~~r Senior Director of Construction Services Facilities Design and Construction UNIVERSITY OF CALIFORNIA, SAN DIEGO.

J~e~~r Senior Director of Construction Services Facilities Design and Construction UNIVERSITY OF CALIFORNIA, SAN DIEGO. BERKELEY DAVIS IR VINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SAN!' A BARBARA SANT A CRUZ OFFICE OF THE ASSIST ANT VICE CHANCELLOR CAMPUS ARCHITECT - FACILITIES DESIGN & CONSTRUCTION TEL:

More information

SPECIAL INSPECTION AGREEMENT

SPECIAL INSPECTION AGREEMENT DEVELOPMENT SERVICES DEPARTMENT BUILDING AND SAFETY DIVISION 156 S. BROADWAY, SUITE 130 TURLOCK, CALIFORNIA 95380 PHONE 209-668-5560 FAX 209-668-5107 SPECIAL INSPECTION AGREEMENT PERMIT NUMBER: DATE: OWNER:

More information

Statement of Special Inspections 2013 CBC

Statement of Special Inspections 2013 CBC BUILDIG & SAFET DIVISIO 2729 Prospect Park Drive Rancho Cordova, CA 95670 Phone: (916) 851-8760 Fax: (916) 851-8762 Statement of Special Inspections 2013 CBC PERMIT #: PROJECT ADDRESS: This Statement of

More information

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831) County of Santa Cruz PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA 95060 (831) 4542580 FA: (831) 4542131 STATEMENT OF SPECIAL INSPECTIONS California Building Code 1704.3 Prior to issuance,

More information

UNIVERSITY OF CALIFORNIA, SAN DIEGO

UNIVERSITY OF CALIFORNIA, SAN DIEGO BERKELEY DAVIS IRVINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SANT A BARBARA SANT A CRUZ OFFICE OF THE ASSIST ANT VICE CHANCELLOR CAMPUS ARCHITECT- FACILITIES DESIGN & CONSTRUCTION TEL: (858)

More information

STATEMENT OF SPECIAL INSPECTION FORM

STATEMENT OF SPECIAL INSPECTION FORM Project Title: Permit #: Project Address: STATEMENT OF SPECIAL INSPECTION FORM This Statement of Special Inspections is submitted in fulfillment of the requirements of CBC Sections 1704 and 1705. Special

More information

SPECIAL INSPECTION AND TESTING AGREEMENT

SPECIAL INSPECTION AND TESTING AGREEMENT COUNTY OF MENDOCINO DEPARTMENT OF PLANNING AND BUILDING SERVICES 860 NORTH BUSH STREET UKIAH CALIFORNIA 95482 120 WEST FIR STREET FT. BRAGG CALIFORNIA 95437 STEVE DUNNICLIFF, DIRECTOR PHONE: 707-234-6650

More information

SPECIAL INSPECTION AGREEMENT FORM

SPECIAL INSPECTION AGREEMENT FORM CITY OF TRACY DEVELOPMENT & ENGINEERING SERVICES 333 CIVIC CENTER PLAZA, TRACY, CA 95376 P :( 209) 831-6400 F :( 209) 831-6439 http://www.ci.tracy.ca.us SPECIAL INSPECTION AGREEMENT FORM Prior to issuance

More information

SPECIAL INSPECTION AGREEMENT

SPECIAL INSPECTION AGREEMENT PART 1 STATEMENT OF SPECIAL INSPECTIONS When special inspection is required to be performed in accordance with International Building Code Chapter 17, a building permit cannot be issued until a statement

More information

Building Department Informational Handout

Building Department Informational Handout City of Sonoma Building Department Informational Handout Statement of Special Inspections Handout No: 7 Revised 1/12/2017 Project Name: Project Address: For building permit applications of projects requiring

More information

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE SECTION 01 43 29 (00041) SPECIAL INSPECTIONS PART 1 GUIDELINES As defined by the IBC 2003, Section 1704, Special Inspections of materials, installation, fabrication, erection of components and connections

More information

UNIVERSITY OF CALIFORNIA, SAN DIEGO

UNIVERSITY OF CALIFORNIA, SAN DIEGO BERKELEY DAVIS IRVINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SANT A BARBARA SANT A CRUZ OFFICE OF THE ASSIST ANT VICE CHANCELLOR CAMPUS ARCHITECT- FACILITIES DESIGN & CONSTRUCTION TEL: (858)

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION Permit Application #: Project Address: Purpose: To meet the requirements of CBC Section 1704.3 this form may be used as a statement

More information

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2) Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction

More information

INSPECTION GUIDELINES: SPECIAL INSPECTION REQUIREMENTS

INSPECTION GUIDELINES: SPECIAL INSPECTION REQUIREMENTS Special Inspection Requirements Page 1 of 8 Revision Date: 08/07/2018 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION GUIDELINES: SPECIAL INSPECTION REQUIREMENTS INSPECTION CODE: N/A SCOPE: RESIDENTIAL

More information

City of Westerville Guide to Commercial Inspections

City of Westerville Guide to Commercial Inspections City of Westerville Guide to Commercial Inspections FOOTINGS - After the excavation, with the form work and any required reinforcing steel in place. All footings shall have loose soil removed, reinforcing

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division Permit Application #: Project Address: Purpose: To meet the requirements of City of Walnut Creek Municipal Code Section

More information

UNIVERSITY OF CALIFORNIA, SAN DIEGO

UNIVERSITY OF CALIFORNIA, SAN DIEGO UNIVERSITY OF CALIFORNIA, SAN DIEGO BERKELEY DAVIS IRVINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SANTA BARBARA SANTA CRUZ OFFICE OF THE ASSIST ANT VICE CHANCELLOR CAMPUS ARCHITECT- FACILITIES

More information

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012) Gaines Charter Township 8555 Kalamazoo Ave SE Caledonia MI 49316 PH: 616 698-6640 Fax: 616 698-2490 www.gainestownship.org Building Department Statement of Special Inspections Michigan Building Code 2012

More information

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company PRINCE WILLIAM COUNTY Department Development Services Building Development Division STATEMENT OF SPECIAL INSPECTIONS (Building/Other Structures other than Retaining Walls) Version 2015-12-31 Building Permit

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012. DELTA TESING LABS 23 South Macquesten Parkway Mount Vernon, NY Brandon Price

SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012. DELTA TESING LABS 23 South Macquesten Parkway Mount Vernon, NY Brandon Price SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012 DELTA TESING LABS 23 South Macquesten Parkway Mount Vernon, NY 10550 Brandon Price 914 699 0056 INSPECTION BODY Valid To: October 31, 2019 Certificate Number:

More information

City of Omaha Plans and Permits Commercial Alterations and Conversions Building Permit Submittal Checklist

City of Omaha Plans and Permits Commercial Alterations and Conversions Building Permit Submittal Checklist City of Omaha Plans and Permits Commercial Alterations and Conversions Building Permit Submittal Checklist This checklist contains the standard information required on submittals for commercial construction

More information

Washoe County PLAN SUBMITTAL

Washoe County PLAN SUBMITTAL Washoe County PLAN SUBMITTAL Washoe County PLAN SUBMITTAL SPECIAL INSPECTION AND TESTING AGREEMENTS SEPTEMBER 2013 Washoe County Permits Plus Zone 1001 East Ninth Street PO Bo 11130 Reno, NV 89520-0027

More information

SPECIAL INSPECTION AND TESTING FORM

SPECIAL INSPECTION AND TESTING FORM Building Division SPECIAL INSPECTION AND TESTING FORM 4381 Broadway, Suite 201 American Canyon, CA 94503 Inquiries: (707) 647-4581 Inspection Request: (707) 551-4619 www.cityofamericancanyon.org Revision

More information

2016 Port of San Francisco Building Code

2016 Port of San Francisco Building Code PORT CODE PROCEDURE NO. : DATE : December 5, 2012 SUBJECT : Permit Process; Inspection TITLE : Special Inspection and Structural Observation Procedures PURPOSE : The purpose of this Port Code Procedure

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections Statement Date: Project Name: Building Permit Number: Project Address: Design Professional in Responsible Charge (DPIRC): The following information is being submitted in

More information

UNIVERSITY OF CALIFORNIA, SAN DIEGO

UNIVERSITY OF CALIFORNIA, SAN DIEGO BERKELEY DAVIS IRVINE LOS ANGELES MERCED RIVERSIDE SAN DIEGO SAN FRANCISCO SANT A BARBARA SANT A CRUZ OFFICE OF THE ASSOCIATE VICE CHANCELLOR CAPITAL PROGRAM MANAGEMENT TEL: (858) 534-2177 FAX: (858) 534-4363

More information

Statement of Special Inspection Requirements

Statement of Special Inspection Requirements Statement of Special Inspection Requirements California Building Code Chapter 17 Construction plans shall include a statement of special inspection in accordance with CBC chapter 17. The statement of special

More information

Project Address: Name of Person Completing Form:

Project Address: Name of Person Completing Form: Statement of Inspections This form is provided as a way to list aspects of the project that require special inspection and testing in accordance with IBC Sections 107.1, 1704, and 1705 and define duties

More information

HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS

HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS Appendix A HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS PROJECT PERMIT APPLICANT PRIMARY RDP OF RECORD STRUCTURAL ENGINEER OF RECORD This Statement of Special Inspections is submitted as a condition

More information

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS 2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS HECO-6 GENERAL Pre-construction conference Preconstruction meeting Scheduled by SI with the Contractor, UBO, A/E, and relevant subs prior to commencement

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections SUCF Project No: Project Title: Registered Design Professionals in Responsible Charge: (Name) (Address) Architect: Structural Engineer: Mechanical Engineer: Identification

More information

PLAN SUBMITTAL REQUIREMENTS - ARCHITECTURAL

PLAN SUBMITTAL REQUIREMENTS - ARCHITECTURAL FIRE DEPARTMENT 10573 E Stockton Blvd. Elk Grove, CA 95624 (916) 405-7100 Fax (916) 685-6622 www.yourcsd.com PLAN SUBMITTAL REQUIREMENTS - ARCHITECTURAL I Purpose To advise architects, engineers and contractors

More information

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist This checklist is a convenient reference to the 2012 Michigan Building Code. The checklist

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections Project: Location: Owner: Design Professional in Responsible Charge: This Statement of Special Inspections is submitted as a condition for permit issuance in accordance

More information

Wood County Building Inspection

Wood County Building Inspection Wood County Building Inspection Michael J. Rudey, Chief Building Official Statement of Special Inspections (Section 1704 Ohio Building Code) Project File Number: Project Name: Project Location: Building

More information

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE STAFF USE ONLY RECEIVED BY: DATE: Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE Applicant must complete numbered items

More information

SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL SECTION 051200 STRUCTURAL STEEL PART 1 GENERAL 1.01 SECTION INCLUDES A. Structural steel framing members and support members. B. Base plates, shear stud connectors. C. Grouting under base plates. 1.02

More information

Statement. Special Inspection

Statement. Special Inspection Statement of Special Inspection Special Inspection Approval Project Name: Location: Owner: Owner s address: Architect of Record: Structural Engineer of Record: The Statement of Special Inspections printed

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

County of Yolo Development Services Building Inspection Division

County of Yolo Development Services Building Inspection Division County of Yolo Development Services Building Inspection Division 292 W. Beamer Street Woodland, CA. 95695 www.yolocounty.org (530) 666-8775 Mechanical Plan Review Comments Plan Review No. Owners Name Job

More information

PROJECT: TULSA COMMUNITY COLLEGE BOOKSTORE RENOVATION PROJECT NUMBER: ISSUE: CONSULTANT: SEAL: SHEET NUMBER: GENERAL NOTES

PROJECT: TULSA COMMUNITY COLLEGE BOOKSTORE RENOVATION PROJECT NUMBER: ISSUE: CONSULTANT: SEAL: SHEET NUMBER: GENERAL NOTES GENERAL NOTES TYPICAL DETAILS REQUIRED VERIFICATION & INSPECTION OF CONCRETE CONSTRUCTION VERIFICATION AND INSPECTION 1. Inspection of reinforcing steel, including prestressing tendons and placement. 2.

More information

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2)

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2) STAFF USE ONLY RECEIVED BY: DATE: Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2) Applicant must complete

More information

Technical Services Division 1660 Mission Street San Francisco CA Office (415) FAX (415)

Technical Services Division 1660 Mission Street San Francisco CA Office (415) FAX (415) City and County of San Francisco Department of Building Inspection Edwin M. Lee, Mayor Tom C. Hui, S.E., C.B.O., Director ADMINISTRATIVE BULLETIN NO. AB-046 DATE : September 18, 2002 (Updated 01/01/2017

More information

INSPECTION REQUIREMENTS: FOUNDATIONS

INSPECTION REQUIREMENTS: FOUNDATIONS Foundations Page 1 of 9 Revision Date: 1/2/2018 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION REQUIREMENTS: FOUNDATIONS INSPECTION CODE: 204 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

Owner... Contractor... City/St... Zip... Phone... City/St... Zip... Phone...

Owner... Contractor... City/St... Zip... Phone... City/St... Zip... Phone... COUNTY OF MENDOCINO DEPARTMENT OF PLANNING AND BUILDING SERVICES 860 NORTH BUSH STREET UKIAH CALIFORNIA 95482 120 WEST FIR STREET FORT BRAGG CALIFORNIA 95437 STATEMENT OF SPECIAL INSPECTIONS STEVE DUNNICLIFF,

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections Project: Location: Owner: Design Professional in Responsible Charge: This Statement of Special Inspections is submitted as a condition for permit issuance in accordance

More information

City of Bozeman Building Division - Special Inspection and Testing

City of Bozeman Building Division - Special Inspection and Testing City of Bozeman Building Division - Special Inspection and Testing To Applicants of Projects Requiring Special Inspection or Testing Per Chapter 17 of the IBC BEFORE A PERMIT CAN BE ISSUED: The owner or

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- STRUCTURAL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- STRUCTURAL SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- STRUCTURAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI)

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI) EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI) For this example let s consider a single-story retail shell building. The main structural walls consist of CMU construction with the front of the building

More information

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011. DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012

SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012 SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012 SPECIAL TESTING & CONSULTING, LLC. 144 Toledo Street Farmingdale, NY 11735 Sebastian Setteducate, P.E. 631-755-1112 INSPECTION BODY Valid To: September 30,

More information

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE STAFF USE ONLY RECEIVED BY: DATE: Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE Applicant must complete numbered items

More information

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit Plan Check/PCIS App #: Job Address: P.C. Engineer: Phone: (E -mail: first name.last name@ lacity.org) For instructions and other information,

More information

STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department

STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department 1 2 STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department 3 4 5 6 7 PROJECT INFORMATION: Project Name: Owner Name: Architect/Engineer Name: FORM PREPARED BY: Project Address:

More information

STATEMENT OF SPECIAL INSPECTIONS - MBC-2012

STATEMENT OF SPECIAL INSPECTIONS - MBC-2012 1 2 STATEMENT OF SPECIAL INSPECTIONS - MBC-2012 CHARTER TOWNSHIP OF WEST BLOOMFIELD BUILDING DEPARTMENT 3 4 5 6 7 8 9 10 11 12 13 PROJECT INFORMATION: Project Name: Owner Name: Architect/Engineer Name:

More information

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 48 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012. MUNICIPAL TESTING LABORATORY, INC. 375 Rabro Drive Hauppauge, NY Michael Jaycox

SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012. MUNICIPAL TESTING LABORATORY, INC. 375 Rabro Drive Hauppauge, NY Michael Jaycox SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012 MUNICIPAL TESTING LABORATORY, INC. 375 Rabro Drive Hauppauge, NY 11788 Michael Jaycox 631-761-5555 INSPECTION BODY Valid To: July 31, 2019 Certificate Number:

More information

SECTION SEISMIC CONTROL OSHPD

SECTION SEISMIC CONTROL OSHPD SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components

More information

SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17, 2015 EDITION

SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17, 2015 EDITION SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17, 2015 EDITION When uired All projects that require a SC Licensed Architect or Engineer per SC Architectural and Engineering Registration Law. Overview The program

More information

Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/

Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/ 120 Montgomery Street, Suite 1410 San Francisco, California 94104 415/781-1505 Fax 415/781-2718 sde@sdesf.com Rajendra Sahai, SE Principal John W. Laws, SE Principal Steven Lepisto, SE Principal STRUCTURAL

More information

RESIDENTIAL REMODELS ADDITIONS AND ALTERATIONS

RESIDENTIAL REMODELS ADDITIONS AND ALTERATIONS RESIDENTIAL REMODELS ADDITIONS AND ALTERATIONS PLAN CHECK SUBMITTAL RESIDENTIAL ADDITIONS/ALTERATIONS Design Criteria Seismic Design Category D (Most cases) Basic Wind Speed 85 mph Exposure B or C Maximum

More information

SPRAY BOOTH REQUIREMENTS

SPRAY BOOTH REQUIREMENTS SPRAY BOOTH REQUIREMENTS Submittal Requirements: 4 sets of plans 2 sets of calculations 2 sets of manufacture specifications and/or cut sheets Plans shall be a minimum size of 11x17 Calculations shall

More information

SPRAY BOOTH REQUIREMENTS

SPRAY BOOTH REQUIREMENTS SPRAY BOOTH REQUIREMENTS Submittal Requirements: 4 sets of plans 2 sets of calculations 2 sets of manufacture specifications and/or cut sheets Plans shall be a minimum size of 11x17 Calculations shall

More information

Plan Check No. Checked by: An Appointment Is Required for Verification

Plan Check No. Checked by: An Appointment Is Required for Verification SUPPLEMENTAL CORRECTION SHEET UNREINFORCED MASONRY (URM) RETROFIT ( 2002 LABC ) Plan Check No. Checked by: Permit Appl. # An Appointment Is Required for Verification Job Address: For appt. call: APPLICATION

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Summary of Modifications/Changes in this Update

Summary of Modifications/Changes in this Update Summary of Modifications/Changes in this Update This Summary of Changes is for information only. It is not a part of the referenced document, and should not be used for project documentation. U.S. Department

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION SUPPORTS AND ANCHORS

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION SUPPORTS AND ANCHORS OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Supports and anchors for piping systems and equipment. 1.2 RELATED WORK SPECIFIED ELSEWHERE A. The provisions of Section 15050, Basic

More information

Cannabis Related Occupancies Commercial Building Permit Application Submittal Requirements

Cannabis Related Occupancies Commercial Building Permit Application Submittal Requirements Cannabis Related Occupancies Commercial Building Permit Application Submittal Requirements The following regulations pertain to City of Sacramento Building Division and Fire Department requirements for

More information

SPECIAL INSPECTION PROGRAM GUIDE

SPECIAL INSPECTION PROGRAM GUIDE CHARTER TOWNSHIP OF WEST BLOOMFIELD BUILDING DEPARTMENT SPECIAL INSPECTION PROGRAM GUIDE 9/5/08 TABLE OF CONTENTS Page No. INTRODUCTION 1 GENERAL GUIDELINES FOR THE SPECIAL INSPECTION PROGRAM.. 2 Purpose

More information

B. RESIDENTIAL MASTER PLUMBER $ $ $

B. RESIDENTIAL MASTER PLUMBER $ $ $ FEE SCHEDULE FOR LICENSE Res. Non-Res. Out of State BUILDING CATEGORIES A. GENERAL CONTRACTOR (Unlimited Scope) B. BUILDING CONTRACTOR $ 100.00 $ 150.00 $ 300.00 Limited to construction and remodeling

More information

ADDENDUM NUMBER 3 AUGUST 18, Jackson County Utility Authority Project No Pascagoula/Moss Point WWTP Escatawpa WWTP Repairs

ADDENDUM NUMBER 3 AUGUST 18, Jackson County Utility Authority Project No Pascagoula/Moss Point WWTP Escatawpa WWTP Repairs ADDENDUM NUMBER 3 AUGUST 18, 2016 Jackson County Utility Authority Project No. 20150619124 Pascagoula/Moss Point WWTP Escatawpa WWTP Repairs FROM: BURK-KLEINPETER, INC. ENGINEERS, ARCHITECTS, PLANNERS,

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 0548 - PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION: SECTION 13 05 41 SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED 1-25-13 PART 1 GENERAL 1.1 DESCRIPTION: A. Provide seismic restraint in accordance with the requirements of this section

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections SUCF Project No: Project Title: Registered Design Professionals in Responsible Charge: (Name) (Address) Architect: Structural Engineer: Mechanical Engineer: Identification

More information

REQUEST FOR STATEMENTS OF QUALIFICATIONS FOR TESTING AND SPECIAL INSPECTION SERVICES UNIVERSITY OF CALIFORNIA, MERCED STUDENT SERVICES BUILDING (SSB)

REQUEST FOR STATEMENTS OF QUALIFICATIONS FOR TESTING AND SPECIAL INSPECTION SERVICES UNIVERSITY OF CALIFORNIA, MERCED STUDENT SERVICES BUILDING (SSB) FOR TESTING AND SPECIAL INSPECTION SERVICES UNIVERSITY OF CALIFORNIA, MERCED (SSB) PROJECT NO. 900120 AND HOUSING PHASE 4 (H4) PROJECT NO. 906270 August 2011 TABLE OF CONTENTS 1. Introduction 2. Project

More information

Angio to Cath. Lab Renovation ADDENDUM #2 12/29/2017

Angio to Cath. Lab Renovation ADDENDUM #2 12/29/2017 Angio to Cath. Lab Renovation ADDENDUM #2 12/29/2017 1. Please see the attached revised Bid Form. 2. Please see the attached Bid Addendum No. 2 Document produced by Sfeir Architects BID SCHEDULE for Angio

More information

REQUEST FOR PROPOSAL FOR MATERIAL TESTING AND SPECIAL INSPECTION SERVICES

REQUEST FOR PROPOSAL FOR MATERIAL TESTING AND SPECIAL INSPECTION SERVICES REQUEST FOR PROPOSAL FOR MATERIAL TESTING AND SPECIAL INSPECTION SERVICES DATE: November 13, 2018 PROJECT: OWNER: BUDGET: University Farm Pavilion College of Agriculture and Environmental Services NC A&T

More information

STRUCTURAL TESTS AND SPECIAL INSPECTIONS

STRUCTURAL TESTS AND SPECIAL INSPECTIONS CHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONS SECTION 1701 GENERAL 1701.1 Scope. The provisions of this chapter shall govern the quality, workmanship and requirements for materials covered. Materials

More information

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA 94596 (925) 943-5834 phone (925) 256-3500 fax Issued July 22, 2010 Information Bulletin No. IB-016 DOCUMENT SUBMITTAL

More information

Georgia State Amendments to the International Building Code

Georgia State Amendments to the International Building Code Georgia State Amendments to the International Building Code (2006 Edition) Georgia Department of Community Affairs Planning and Environmental Management Division 60 Executive Park South, N.E. Atlanta,

More information

INSPECTION REQUIREMENTS Page 1 of 5. JOB SITE ADDRESS posted during entire construction process.

INSPECTION REQUIREMENTS Page 1 of 5. JOB SITE ADDRESS posted during entire construction process. INSPECTION REQUIREMENTS Page 1 of 5 JOB SITE ADDRESS posted during entire construction process. JOB PLACARD POSTED IN PLAIN SIGHT: GREEN Placard - Building, ORANGE Placard Electrical, BLUE Placard - HVAC,

More information

SECTION METAL STAIRS

SECTION METAL STAIRS SECTION 05 51 00 METAL STAIRS PART 1 GENERAL 1.1 SUMMARY A. Section includes steel stair frame of structural sections, with closed risers; pan to receive concrete fill stair treads and landings; integral

More information

4. Number of drawings required: ( ) Locations of nearest streets

4. Number of drawings required: ( ) Locations of nearest streets CITY OF MANSFIELD BUREAU OF BUILDING AND CODES 30 NORTH DIAMOND STREET 3RD FLOOR MANSFIELD, OHIO 44902 Phone (419) 755-9688 Fax (419) 755-9453 www.ci.mansfield.oh.us COMMERCIAL BUILDING PLAN REQUIREMENTS

More information

Chapter 2 QUALITY ASSURANCE

Chapter 2 QUALITY ASSURANCE Chapter 2 QUALITY ASSURANCE 2.1 GENERAL 2.1.1 Scope. This chapter provides minimum requirements for quality assurance for seismic-forceresisting systems and designated seismic systems. These requirements

More information

CALIFORNIA ERIC GARCETTI MAYOR

CALIFORNIA ERIC GARCETTI MAYOR BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE PRESIDENT CITY OF LOS ANGELES CALIFORNIA DEPARTMENT OF BUILDING AND SAFETY 201 NORTH FIGUEROA STREET LOS ANGELES,

More information

List of Required Structural Tests & Special Inspections CBC

List of Required Structural Tests & Special Inspections CBC Page 1 of 8 School Name COLLEGE OF ALAMEDA IMPORTANT: This form is only a summary list of structural tests and some of the special inspections required for the project. Generally, the structural tests

More information

Forms. VR Form 1 - Special Inspector Roster and Contact Information 2. VR Form 2 - Participating Jurisdiction Roster and Contact Information 5

Forms. VR Form 1 - Special Inspector Roster and Contact Information 2. VR Form 2 - Participating Jurisdiction Roster and Contact Information 5 Chapter Forms Page 1 VR Form 1 - Special Inspector Roster and Contact Information 2 VR Form 2 - Participating Jurisdiction Roster and Contact Information 5 VR Form 3 - Application - Recognized Special

More information

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and & &01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.

More information

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued) 2000 IRC 1997 NEHRP Section Provision Section Provision Comments CHAPTER 3 BUILDING PLANNING R301 DESIGN CRITERIA R301.2.2 Seismic Provisions R301.2.2.1 Determination of Seismic Design Category R301.2.2.1.1

More information

Houston First Corporation Package 1

Houston First Corporation Package 1 SECTION 260548 VIBRATION CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

THE CITY OF WALTHAM MASSACHUSETTS PURCHASING DEPARTMENT PHASE III RENOVATIONS TO THE FORMER BANKS SCHOOL ELDERLY HOUSING CONDOMINIUMS AND CONDOMINIUMS

THE CITY OF WALTHAM MASSACHUSETTS PURCHASING DEPARTMENT PHASE III RENOVATIONS TO THE FORMER BANKS SCHOOL ELDERLY HOUSING CONDOMINIUMS AND CONDOMINIUMS THE CITY OF WALTHAM MASSACHUSETTS PURCHASING DEPARTMENT PHASE II RENOVATIONS TO THE FORMER BANKS SCHOOL ELDERLY HOUSING CONDOMINIUMS AND PHASE III RENOVATIONS TO THE FORMER BANKS SCHOOL ELDERLY HOUSING

More information

TERM CONTRACT FOR PROFESSIONAL MATERIALS TESTING and INSPECTION SERVICES CHAPTER TWO PROFESSIONAL S REQUIRED SERVICES

TERM CONTRACT FOR PROFESSIONAL MATERIALS TESTING and INSPECTION SERVICES CHAPTER TWO PROFESSIONAL S REQUIRED SERVICES TERM CONTRACT FOR PROFESSIONAL MATERIALS TESTING and INSPECTION SERVICES TABLE OF CONTENTS 1) General... Page 3 2) Qualifications. Page 3 3) Reporting Page 7 4) Other Conditions... Page 9 5) Inspection

More information

ADDENDUM NUMBER 10 TO THE PLANS AND SPECIFICATIONS FOR

ADDENDUM NUMBER 10 TO THE PLANS AND SPECIFICATIONS FOR ADDENDUM NUMBER 10 TO THE PLANS AND SPECIFICATIONS FOR FOR LAWTON PUBLIC SCHOOLS FREEDOM ELEMENTARY SCHOOL Architect s Project Number: N09017 ARCHITECTURE PLANNING INTERIORS Date: 04.16.13 The following

More information

POOLS, SPAS AND HOT TUBS

POOLS, SPAS AND HOT TUBS POOLS, SPAS AND HOT TUBS City of San Juan Capistrano Development Services Department 32400 Paseo Adelanto San Juan Capistrano, CA 92675 Phone: (949) 493-1171 Fax: (949) 661-5451 http://www.sanjuancapistrano.org/

More information