1 SECTION ( ) MSI PRECAST STONE VENEER SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. MSI Precast Stone Veneer for exterior and interior vertical surfaces. 1.2 RELATED SECTIONS Specifier Notes: Edit the following list of related sections as required for the project. List other sections with work directly related to this section. Delete sections not required. A. Section ( ) Unit Masonry Assemblies (Concrete Unit Masonry): Masonry supporting walls. B. Section ( ) Cold-Formed Metal Framing: Formed steel-framed supporting walls. C. Section ( ) Metal Fabrications: Galvanized shelf angles, structural supports, anchors and other built-in components for building into natural thin veneer stone. D. Section ( ) Wood Framing: Wood frame supporting walls. E. Section ( ) Sheathing: Wood frame supporting walls. F. Section ( ) Joint Sealers (Joint Protection): Sealant and joint filler for perimeter and control joints. G. Section ( ) Portland Cement Plaster (Portland Cement Plastering): Metal lath and scratch coat back-up over supporting walls. 1.3 REFERENCES Specifier Notes: List standards referenced in this section, complete with designations and titles. Delete standards not included in the edited section. This article does not require compliance with standards, but is merely a listing of those used. A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars B. ASTM C Standard Test Method for Flexural Strength of Hydraulic-Cement Mortars C. ASTM C482-02(2009) Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement Paste MSI Precast Stone Veneer ( ) - 1
2 D. ASTM C67 - Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile E. ASTM C567 / C567M - 11 Standard Test Method for Determining Density of Structural Lightweight Concrete F. ASTM C39 / C39M - 12 Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens G. PCA Portland Cement Plaster (Stucco) Manual. H. Uniform Building Code (UBC) Standard 15.5 J. International Conference of Building Officials (ICBO) AC SUBMITTALS Specifier Notes: Edit submittal requirements as required. Delete submittal types not required. A. Comply with Section ( ) Submittal Procedures. B. Product Data: Submit manufacturer's product data on stone, rail system, and fasteners, including: 1. Surface preparation and installation instructions. 2. Storage and handling instructions. C. Shop Drawings: Submit manufacturer s shop drawings, including plans, elevations, sections, and details, indicating layout, dimensions, anchorages, and jointing methods. D. Verification Samples: Submit 2 manufacturer s full-size samples of MSI precast veneer stone for each pattern specified. E. Warranty: Submit manufacturer s standard warranty for MSI panelized stone veneer system. 1.5 QUALITY ASSURANCE A. Manufacturer s Qualifications: Manufacturer regularly engaged, for preceding 10 years, in manufacture of MSI precast stone veneer stone of similar type to that specified. Specifier Notes: Include a mock-up if the project size or quality warrant taking such a precaution. Edit mock-ups as required. Delete mock-ups if not required. B. Mock-Ups: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. 1. Finish areas designated by Architect. 2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect. 3. Refinish mock-up area as required to produce acceptable work. MSI Precast Stone Veneer ( ) - 2
3 1.6 DELIVERY, STORAGE, AND HANDLING A. Delivery: Deliver materials to site in manufacturer s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Storage: 1. Store materials in accordance with manufacturer s instructions. 2. Store materials in manufacturer's unopened packaging until ready for installation. 3. Store stone materials on pallets on dry, level surface and cover with tarps if heavy rain is anticipated. 4. Do not stack pallets. C. Handling: Protect materials during handling and installation to prevent damage or contamination. 1.7 PROJECT ENVIRONMENTAL REQUIREMENTS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. B. Do not install MSI Precast Stone Veneer under environmental conditions outside manufacturer's limits. PART 2 PRODUCTS 2.1 MANUFACTURER A. M-Rock, Inc., PO Box 458, Peterstown, WV Toll Free (866) Phone (304) Fax (304) Website Sean@m-rockstone.com 2.2 MSI PRECAST STONE VENEER Specifier Notes: MSI Precast Stone Veneer collections and patterns are listed alphabetically. Specify required collections and patterns. Delete collections and patterns not required. 1. Collection: Aspen" Ledge Stone. d. Color: Slate gray tones with cream/ecru and firebrick red touch. 2. Collection: Horizon Dry Stack Stone. d. Color: Beige and tan tones with red/light red touch. MSI Precast Stone Veneer ( ) - 3
4 3. Collection: Indian Creek" Canyon Stone. d. Color: Beige and tan tones with red/light red touch. 4. Collection: Meridian Ledge Stone. d. Color: Beige tones with red/light red and gray or black touch. 5. Collection: Reveal Dry Stack Stone. d. Color: Slate gray tones with cream/ecru and firebrick red touch. 6. Collection: The Gray or Blackstone" Canyon Stone. d. Color: Gray tones with light red touch. 2.3 SPECIAL SHAPES Specifier Notes: Specify special shapes as required. Delete special shapes not required. Indicate location and sizes of special shapes on the Drawings. A. Provide special shapes as indicated on the Drawings and as follows: 1. Trimstones. 2. Hearthstones. 3. Keystones. 4. Rockface sills. 5. Corners (inside / outside) 6.. B. Color: Specifier Notes: Specify color of special shapes as required. Delete colors not required. 1. Cream/ecru. 2. Slategray. 3. Tan. 4. Beige 5. Firebrick red. 6. Gray or black. MSI Precast Stone Veneer ( ) - 4
5 2.4 ACCESSORIES A. M-Trim: 42 inches and available in gray an brown tones. Two Piece System Adhesive Bond allows for different stones Universal design for all projects Cuts easily for wrapping corners or windows Cuts / Finishes any termination point B. Starter strip: This is used along the bottom row of the stone to lock the First Row into place. C. Universal Trim: A 2 x20 trim piece that can be used in many different ways, depending on the project. It can be used to finish the top of a project area, to trim around windows and doors, or to butt the stone to another surface. D. Column Cap: M-Rock s Pyramid Post Cap has a 2 overhang to conceal the top of your last row of stone. E. Column Trim (Post Trim Ring): This trim allows the post to continue up and it is designed to be used with MSI Post Surrounds. F. Column Stones: Each column stone is custom designed for installation right out of the box. The sizes are 16"x16" / 6"x6" / 5 1/2"x5 1/2". G. Fireplace Trim Kit: Each section of the trim kit is manufactured with a metal bracket for easier installation. Kit includes a key stone, customizable right and left peripheral stones, and hearth stone. Hearth stone sizes are 12"x20"x2" / 20"x20"x2"/ 24"x24"x2" / 12"x12"x1 1/2" / 16"x20"x2". H. MSI Receptacle Stone: Brown and gray. PART 3 EXECUTION 3.1 EXAMINATION A. Examine surfaces to receive MSI Precast Stone Veneer. B. Notify Architect of conditions that would adversely affect installation. C. Do not begin surface preparation or installation until unacceptable conditions are corrected. D. Do not begin installation until backing structure is plumb, bearing surfaces are level, and substrates are clean and properly prepared. E. Verify location and secure installation if shelf angles are required. MSI Precast Stone Veneer ( ) - 5
6 3.2 SURFACE PREPARATION A. Exterior Untreated Wood Installation: For exterior untreated wood installation a moisture barrier, such as 15Ibs felt or a synthetic barrier is required. B. Exterior Treated Wood Installation: No moisture barrier is required when using treated plywood. C. Interior Wood Installation: No moisture barrier is required. D. Interior Drywall: MSI veneer stone can be installed over drywall. 1. Hit one stud per stone, OR 2. Use some type of drywall anchor. E. Block Installation: MSI can be installed over block with a masonry screw to apply stone to block. It is recommended that the block be sealed before MSI veneer stone installation. 3.3 INSTALLATION A. Starter Strip: 1. New starter strip is to be placed at bottom elevation of project. To install Starter Strip measure up 1 1/2" from the bottom of your project area, chalk a line to mark where your Starter Strip will be installed,. For multiple Starter Strips be sure to continue your line the entire length of the project area. Starter Strip is not always necessary, but the bottom section of the first row of stone may not be as tight as when using the Starter Strip. 2. The screws need to be drilled through the "V" channel of the Starter Strip (d1) and will be drilled directly onto your pre-measured and marked line, placing a screw every inches along the Starter Strip. Each strip needs to be leveled. B. First Row of MSI Precast Stone Veneer: 1. When inside and/or outside corners are present, start with inside corners first, then outside corners., finally fill in between with flats. The first row locks onto the Starter Strip and the stones work better from left to right. 2. At the end of the each row, measure and make the appropriate cut, using the remaining piece to begin next row. Screw into framing members when possible. C. Following Rows of MSI Precast Stone Veneer: 1. The second row and all following rows will stack and fasten directly onto the previous row of MSI stone. Make cuts as necessary, making sure to stagger each row. 2. Use cut pieces in and throughout the project. D. Finishing: 1. M-Trim should be considered as the 1st option. 2. Universal Trim: Universal Trim a 2"x20" trim piece. It can be used to finish the top of a project area, to trim around windows and doors, or to butt the stone to another surface. Use a polyurethane construction adhesive to attach the Universal Trim. 3. Piecing the Stone: Cut to height and use a polyurethane construction adhesive to attach the stone. The plastic railing may need to be cut to ensure a tight lock and finish. MSI Precast Stone Veneer ( ) - 6
7 In some situations, pre-drilling a hole may be necessary to attach the last course with a mechanical fastener, i.e. galvanized screws. Use coated screws for exterior applications. E. Cutting and Fitting: 1. MSI can be cut easily with a diamond blade, either by dry cutting or wet. Cut and fit thin veneer stone for chases, pipes, conduit, sleeves, grounds, and other penetrations and adjacent materials. 2. Coordinate with other work to provide correct size, shape, and location. 3.4 CLEANING A. MSI should only be washed with water. Pressure washing is not recommended. B. Do not use harsh cleaning materials or chemicals that could damage stone. C. Do not use metal brushes or acids for cleaning. 3.5 PROTECTION A. Protect installed MSI precast stone veneer to ensure that, except for normal weathering, stone will be without damage or deterioration at time of Substantial Completion. B. Touch-up, repair, or replace damaged stone before Substantial Completion. END OF SECTION MSI Precast Stone Veneer ( ) - 7
Product Guide Specification
Product Guide Specification SECTION 04850 (04 40 00) NATURAL THIN VENEER STONE PART 1 GENERAL 1.1 SECTION INCLUDES Specifier Notes: Edit the following as required. A. Natural thin veneer stone for [exterior]
More informationSPECIFICATION GUIDELINE
Environmental StoneWorks specification guideline should be used to assist design professionals in the preparation of projects. Edit and delete items that may not be applicable. Verify all referenced section
More informationSPECIFICATION GUIDELINE
SPECIFICATION GUIDELINE Environmental Stoneworks Corporate Office 6300 East Stapleton Drive South Denver, CO 80216 Phone (303) 309-3040 Fax (303) 309-3059 www.estoneworks.com Environmental Stoneworks specification
More informationNative Custom Stone Guide Specification 1/30/2012 SECTION MANUFACTURED STONE VENEER
1/30/2012 SECTION 04 70 00 MANUFACTURED STONE VENEER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Manufactured stone veneer masonry, accessories, and related materials. 1.2 SUBMITTALS A. Product
More informationSECTION ORNAMENTAL ALUMINUM RAILING
SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Decorative Wire Rope Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in
More informationSECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.
SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,
More informationSECTION ORNAMENTAL ALUMINUM RAILING
SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete.
More informationSECTION MANUFACTURED STONE VENEER. A. Section Includes: 1. Manufactured stone veneer masonry, accessories, and related materials.
SECTION 04 70 00 MANUFACTURED STONE VENEER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Manufactured stone veneer masonry, accessories, and related materials. 1.2 SUBMITTALS A. Product Data: For
More informationSpecifier Note: Retain material(s) below to conform to project requirements.
550 E 56 HWY STE B OLATHE, KS 66061 PHONE: 913.254.9300 FAX: 913.254.9301 The Canyon Stone Spec. Manual specifies manufactured stone veneer, manufactured brick veneer and manufactured stone trim. These
More informationSpec Master 5/7/ For each product requiring color and texture selection, provide full size samples.
SECTION 04812 (042012) MECHANICALLY ATTACHED BRICK PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationMARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes: 1. Reinforced fiber-cement shingle panel siding, 2. Reinforced fiber-cement lap siding. B. Related Sections: 1. Division 1 Section "Quality Requirements"
More informationSECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.
SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,
More informationSECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE
SECTION 08 33 00 SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on
More informationSECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME
SECTION 08331 OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES
More informationSECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) ** NOTE TO SPECIFIER ** Wayne Dalton; Coiling counter door products.. This section is based
More informationMANUFACTURER S SPECIFICATION
MANUFACTURER S SPECIFICATION Eldorado Stone Corporation PO Box 489 Carnation, WA 98014 Tel: (800) 925-1491 Fax: (425) 333-4755 e-mail: general@eldoradostone.com website: www.eldoradostone.com SECTION 04730
More informationSECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Welded stainless steel railing systems. 1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete; coordination with substrate.
More informationMarlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.
Note: This document contains information and notes in hidden text. If you need assistance to view & hide text, instructions are at this link: http://www.marlite.com/hidden-notes-instructions.aspx Delete
More informationSECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter
More informationSECTION PERFORATED METAL. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 05735 PERFORATED METAL Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Architectural metal. B. Decorative metal. C. Perforated ceiling panels.
More informationSECTION RESIDENTIAL CASEWORK
PART1 GENERAL 1.01 SECTION INCLUDES A. Vanity cabinets. B. Toilet room casework. C. Casework hardware. 1.02 RELATED REQUIREMENTS A. Section 12 36 00 - Countertops. 1.03 REFERENCE STANDARDS SECTION 12 35
More informationby Rollfab Metal Products
by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and
More informationFramed Decorative Panel Systems
Note: This document contains information and notes in hidden text. If you need assistance to view & hide text, instructions are at this link: http://www.marlite.com/hidden-notes-instructions.aspx Delete
More informationProduct Guide Specification
Natural Stone Veneers International, Inc. March 2015 PO Box 347 Fond du Lac, Wisconsin 54936 Toll Free (877) 923-2800 Phone (920) 923-2800 Fax (920) 923-3800 Website www.nsvi.com E-mail info@nsvi.com Product
More informationFaçade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.
SECTION 09 7710 FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Decorative ½ / ¾ (13mm/19mm) thick prefinished panel with preengineered attachment clip along with hardware
More informationSECTION (Master Format, 1995 Edition, 04700) MANUFACTURED MASONRY
SECTION 04 70 00 (Master Format, 1995 Edition, 04700) MANUFACTURED MASONRY PART I - GENERAL 1.01 SUMMARY A. Section Includes: Manufactured Stone Veneer, Manufactured Stone Trim, and Application Materials.
More informationBENJAMIN OBDYKE INCORPORATED
SLICKER CLASSIC OR SLICKER MAX PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Rainscreen for Use in Sidewall Construction. Specifier Note: Revise paragraph below to suit project requirements. If a reader
More informationSECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.
SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,
More informationPhenolic Exterior Wall Cladding
Phenolic Exterior Wall Cladding SECTION 07 42 43 COMPOSITE WALL PANELS This specification includes hidden text for editing for a project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Phenolic wall
More informationThin Architectural Splitface Block Veneer Specification Guide
Thin Architectural Splitface Veneer System with AccuTab Technology R Thin Architectural Splitface Block Veneer Specification Guide Section 04711: Manufactured Concrete Veneer Use this specification guide
More informationProduct Guide Specification
April 2014 6840 SW 81 Terrace Miami, Florida 33143 Phone 305-666-6676 Fax 305-666-7675 Website www.trimstonepanels.com E-mail stoneworks@stoneworksofart.com Product Guide Specification Specifier Notes:
More informationSUNY GENESEO RED JACKET DINING HALL RENOVATION THIN BRICK MASONRY
SUNY GENESEO 042113.13-1 SECTION 042113.13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION EXTERIOR GRILLS AND SCREENS
SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,
More informationSECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE
SECTION 08 33 00 SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round
More informationALUMABOARD SECTION ALUMINUM SIDING AND SOFFITS. A. Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.
ALUMABOARD SECTION 07 46 00 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and accessories.
More informationProduct Guide Specification
April 2014 6840 SW 81 Terrace Miami, Florida 33143 Phone 305-666-6676 Fax 305-666-7675 Website www.trimstonepanels.com E-mail stoneworks@stoneworksofart.com Product Guide Specification Specifier Notes:
More informationHome Depot Page 1 of 5 HDPB Humacao, PR 10/19/09
PART 1 - GENERAL 1.01 SUMMARY A. Types of cold-formed metal framing units include the following: 1. C-shaped steel studs B. Related work specified elsewhere includes but may not be limited to: 1. Section
More informationInstallation Guide Wall Panels
Installation Guide Wall Panels Jointless or Dry-Stacked Installation (Read Prior to installation) The MStone system is a jointless / dry-stacked installation where panels and corners fit tightly together
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationArchitects - Stone Guide Specifications
Architects - Stone Guide Specifications SECTION 04 73 01 MANUFACTURED STONE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Manufactured stone masonry, accessories, and related materials. 1.2 SUBMITTALS
More informationProduct Guide Specification
Natural Stone Veneers International, Inc. June 2017 PO Box 347 Fond du Lac, Wisconsin 54936 Toll Free (877) 923-2800 Phone (920) 923-2800 Fax (920) 923-3800 Website www.nsvi.com E-mail info@nsvi.com Product
More informationSECTION MANUFACTURED MASONRY VENEER
TM Dutch Quality Stone 18012 Dover Road Mt. Eaton, OH 44659 Tel: (330) 359-7866 Fax: (330) 359-5990 e-mail: info@dutchqualitystone.com website: www.dutchqualitystone.com SECTION 04 73 00 MANUFACTURED MASONRY
More informationCorium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
More informationCONCRETE BALUSTRADE SYSTEM
Arto Brick California Pavers 15209 S. Broadway St. Gardena, CA 90248-1823 Phone: (310) 768-8500 Fax: (310) 768-8544 www.artobrick.com This 3-part specification utilizes the Construction Specifications
More informationSECTION GYPSUM BOARD
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 29 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationTrex Commercial Products page Metal Railing
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post Rail (Glass). D. Tensiline Railings (Cable). E. Track Rail (Glass).
More informationSECTION CEMENTITIOUS SHEATHING
SECTION 06 16 63 CEMENTITIOUS SHEATHING SPEC WRITER NOTES: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this Section for exterior sheathing as a backup
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationSECTION STAINLESS STEEL WALL PANELS
SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.
More informationDIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories
04 00 00 MASONRY 04 01 00 Maintenance of Masonry 04 01 20 Maintenance of Masonry 04 05 13 Masonry Mortaring 04 05 23 Masonry Accessories 04 20 00 UNIT MASONRY 04 21 00 Clay Unit and Brick Veneer 04 22
More informationTerraClad TM General Specifications
TerraClad TM General Specifications PRODUCT NAMES: Terra cotta Baguettes/Louvers and Related Work MANUFACTURER: Boston Valley Terra Cotta 6860 S. Abbott Road Orchard Park, NY 14127 Phone: 888-214-3655
More informationMaster Specifications for Microcotta November 2017
SECTION 042130 - MICROCOTTA PART 1 - GENERAL 1.1 SUMMARY A. Provide Architectural Microcotta, cast architectural polymer resin units manufactured in accordance with the Contract Documents. 1.2 WORK INCLUDED
More informationSECTION RESILIENT SHEET FLOORING
SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.
More informationPART 1 GENERAL MANUFACTURED STONE MASONRY
SECTION 04 73 00 (04730) PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Simulated Stone B. Products installed, but not furnished, under this Section include the following: 1. Steel Lintel and Shelf
More informationSTORAGE AND TRANSPORTION
Content 1. General & Notes 2. Substrate Processing 3. Panel Layout 4. Tools 5. Screws 6. Installation instructions 7. Cleaning 8. FAQS 8. MSDS General & Notes In comparison to natural or cast stone, Questone
More information1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.
1 GENERAL 1.1 SECTION INCLUDES 1.1.1.1 Aluminum Siding. 1.1.1.2 Aluminum Soffits. 1.1.1.3 Thermally Broken Façade Sub-structure. 1.1.1.4 Aluminum trim and accessories. 1.2 RELATED SECTIONS 1.2.1 Section
More informationSECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post
More informationSECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.
(Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying cement board supported adhered masonry. The Specifier needs to edit these guide specifications
More informationDIVISION VIII - DOORS AND WINDOWS
DIVISION VIII - DOORS AND WINDOWS SECTION 08121 INTERIOR ALUMINUM DOORS, DOOR FRAMES, AND OFFICE FRONT FRAMING (SOLUTIONS II SYSTEM) PART 1 - GENERAL 1.01 SUMMARY A. Related Documents: Provisions established
More informationSECTION GYPSUM BOARD SYSTEM
PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 09 29 00 GYPSUM BOARD SYSTEM A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections,
More informationSECTION STRUCTURAL INSULATED PANELS
SECTION 06120 STRUCTURAL INSULATED PANELS Copyright 2011-2012 Korwall Industries, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural Insulated Roof Panels. B. Structural Insulated
More informationSECTION TILING
PART 1 GENERAL 1.01 SECTION INCLUDES A. Ceramic Tile for floor applications. B. Ceramic Tile for wall applications. C. Ceramic accessories. D. Ceramic trim. E. Non-ceramic trim. 1.02 RELATED REQUIREMENTS
More informationNOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)
NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION MASTERFORMAT SECTION 04818 (Mortarless Concrete Brick Veneer) Spec_USA_En_18102005.doc 12/1/2005 Novabrik Page 2 Section 04818 NOVABRIK MORTARLESS
More information2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:
SECTION 07651 FLEXIBLE COPPER SHEET FLASHINGS Advanced Building Products, Inc. manufacturer many types of flexible copper sheet flashings. Due to their ductility, high tensile strength, and resistance
More informationSECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.
SECTION 03460 EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE PART 1 GENERAL 1.1 SECTION INCLUDES A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels. B. Shop/Plant Cast CMU/Split Face
More informationProduct Guide Specification
HALFEN USA Inc. March 2012 8521 FM 1976 P.O. Box 547 Converse, TX 78109 Toll Free 800-423-9140 Fax 888-277-1695 Website www.halfenusa.com E-mail info@halfenusa.com Product Guide Specification Specifier
More informationRENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11
SECTION 09 29 00 GYPSUM BOARD 05/11 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text
More informationSECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES
SECTION 081613 FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationSECTION Arisfor WallGuard
1.1 GENERAL A. is a three component polymerized cementitious protective coating that can be applied to a variety of vertical interior and exterior substrates including: stucco, exterior gypsum sheathing,
More informationProduct Guide Specification
Advanced Building Products, Inc. July 2010 PO Box 98 Springvale, Maine 04083 Toll Free 800-252-2306 Phone 207-490-2306 Fax 207-490-2998 Website www.advancedflashing.com E-mail info@advancedflashing.com
More informationSECTION / HEAVY DUTY WIRE MESH WINDOW GUARDS
SECTION 10605 / 10 22 13 HEAVY DUTY WIRE MESH WINDOW GUARDS ** NOTE TO SPECIFIER ** heavy duty woven wire mesh partitions, wire mesh infill panels, window guards, and area guarding.. This section is based
More information1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.
WOOD FLOORING GENERAL INFORMATION 1.1 This section applies to factory finished wood strip flooring. 1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards. 1.3
More informationSECTION GYPSUM BOARD SYSTEM
PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 09 29 00 GYPSUM BOARD SYSTEM A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections,
More informationSECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)
Tectum Inc. 105 South Sixth Street Newark, OH 43055 Phone: (888) 977-9691 Phone: (740) 345-9691 Fax: (800) 832-8869 E-mail: info@tectum.com www.tectum.com This MANU-SPEC utilizes the Construction Specifications
More informationProduct Guide Specification
Norplex-Micarta October 2007 665 Lybrand Street Postville, Iowa 52162 Toll Free (800) 568-8108 Phone (817) 329-6191 Fax (817) 421-4208 Website www.stormblocker.com E-mail support@stormblocker.com Product
More informationFYPON, LLC. February 2014
Section 06 66 30 EXTERIOR PVC RAILINGS AND GUARDS PART 1 - GENERAL 1.1 RELATED SECTIONS: A. All contract documents apply to work of this section; this includes but is not limited to: Agreement; Drawings;
More informationHammerStone Manufactured stone veneers for commercial & residential applications
HammerStone Manufactured stone veneers for commercial & residential applications Veneer Stone Specification Guide Section 04711: Manufactured Stone Veneer Use this specification guide for each individual
More informationSECTION FIBER CEMENT SIDING. A. Furnish and install CERACLAD fiber cement rain screen siding system.
SECTION 07466 FIBER CEMENT SIDING PART 1 GENERAL 1.1 SCOPE A. Furnish and install CERACLAD fiber cement rain screen siding system. 1.2 RELATED SECTIONS A. Division 06 - Wood and plastics B. Section 07210-
More informationINTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR ANCHORED MASONRY VENEER SYSTEM WITH POLYSTYRENE FOAM PLASTIC BACKING EC 021-2014 (Adopted
More informationSECTION NATURAL STONE VENEER
CSI 3-PART SPEC Eldorado Stone 1370 Grand Ave., Bldg. B San Marcos, CA 92069 tel: (800) 925-1491 fax: (760) 736-8890 e-mail: contactus@eldoradonatural.com website: www.eldoradonatural.com SECTION 04 43
More informationSECTION SELF-ADHERING SHEET FLASHING
MANUFACTURER S GUIDE SPECIFICATIONS SECTION 076526 SELF-ADHERING SHEET FLASHING 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 604129 03.24.15 Carlisle, Flexphalt, Sure-Seal and CAV-GRIP
More informationSECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?
SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum
More informationStonecraft Industies 8300 County Road Holmesville, OH
Stonecraft Industies 8300 County Road Holmesville, OH Tel: (888) 580-6448 e-mail: customercare@stonecraft.com website: www.stonecraft.com SECTION 04 73 00 MANUFACTURED MASONRY VENEER GENERAL NOTES TO SPECIFIER:
More informationSPECIFICATIONS MODERRA MORTARLESS MASONRY VENEER
SPECIFICATIONS MODERRA MORTARLESS MASONRY VENEER PART 1: GENERAL 1.01 Section Includes A. Product description and definitions. B. Constructing base ledge for concrete wall units. C. Installing modular
More informationSECTION METAL WALL PANELS
Unience USA, Inc. 2115 Linwood Avenue, Suite 500 Fort Lee, NJ 07024 Phone: 201-676-2467 Fax: 201-944-3660 Email: alfrex@alfrexusa.com Web: www.alfrexusa.com SECTION 07 42 13 METAL WALL PANELS PART 1 GENERAL
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationSECTION ** NOTE TO SPECIFIER ** Overhead Door Corp.; Residential Sectional Overhead Door products.
SECTION 08 36 13 RESIDENTIAL OVERHEAD DOORS IMPRESSION COLLECTION INSULATED FIBERGLASS DOORS SERIES 980 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions
More informationPRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS
PRODUCTION SPECIFICATIONS SECTION 03135 INSULATED CONCRETE FORMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulated panel permanent concrete form system for: 1. Exterior structural wall panels. 2. Interior
More informationPRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS
PRODUCTION SPECIFICATIONS SECTION 03135 INSULATED CONCRETE FORMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulated panel permanent concrete form system for: 1. Exterior structural wall panels. 2. Interior
More informationSECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.
SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Handrails and guardrails B. Guardrails for hatches and openings. C. Safety barriers. D. Roof edge protection. 1.2 RELATED SECTIONS
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationA. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.
Section 07 42 13 Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants. 1.2 RELATED SECTIONS A. Section 06112 - Framing
More informationSECTION GYPSUM BOARD & SHEATHING SYSTEMS
PART 1!GENERAL! 1.01! SECTION INCLUDES SECTION 09260 GYPSUM BOARD & SHEATHING SYSTEMS! Metal stud wall framing. Metal channel ceiling framing.! Gypsum board.! Sheathing.! Taped and sanded joint treatment.!
More informationSECTION ALUMINUM WINDOWS
SECTION 08520 ALUMINUM WINDOWS PART 1 GENERAL 1.1 SECTION INCLUDES A. Projected windows. B. Fixed windows. 1.2 RELATED SECTIONS A. Section 07900: Joint Sealers. B. Section 08400: Entrances and Storefronts.
More informationGuide Specification for the OSI QUAD Window and Door Flashing System
Henkel Corporation 26235 First Avenue Westlake, OH 1-866-591-2178 www.ositough.com Guide Specification for the OSI QUAD Window and Door Flashing System Specifier Note: The purpose of this guide specification
More informationSECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof
SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812
More informationPROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS
SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
More informationGENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS
I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green
More informationSECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:
Page 1 of 7 SECTION 083925 MECHANICAL ROOM FLOOD DOORS AND FRAMES **Note to Specifier** This specification contains component and configuration options. Where indicated, choose the appropriate choice for