1 XTENDEX DECKING INSTALLATION GUIDE XTENDEX DECKING SYSTEMS AS SHOWN IN THIS GUIDE MEET THE REQUIREMENTS OF OBC-1997 CCMC PRODUCT EVALUATION REPORT IS PENDING XTENDEX DECKING SYSTEMS AS SHOWN IN THIS GUIDE ALSO MEET THE REQUIREMENTS OF IBC-2003, BOCA-1999, UBC-1997 AND SBC-1999 BUILDING CODES AS DOCUMENTED IN ICC-ES LEGACY EVALUATION REPORT NER-695 January Brock Street, Barrie, Ontario, Canada L4N 2M4 Phone: ; Fax: ; Toll Free: Website:
2 IDEAS SKETCH PAD NOTES BEFORE YOU START CONSULT YOUR LOCAL BUILDING DEPARTMENT BEFORE STARTING, TO ENSURE THAT YOUR PROPOSED PROJECT MEETS THEIR REQUIREMENTS. FOR SAFETY, YOU SHOULD USE CAUTION, CARE, AND GOOD JUDGEMENT WHEN FOLLOWING THE PROCEDURES DESCRIBED ON THIS PAGE AND IN THE XTENDEX SYSTEMS INSTALLATION GUIDE. CONSIDER YOUR OWN SKILL LEVEL AND THE INSTRUCTIONS AND SAFETY PRECAUTIONS ASSOCIATED WITH THE VARIOUS TOOLS AND MATERIALS USED. OBEY BY THE REQUIREMENTS OF THE LATEST OCCUPATIONAL HEALTH AND SAFETY ACT REGULATION FOR CONSTRUCTION PROJECTS WHERE APPLICABLE.
3 CLASSIC 5/4 DECKING SYSTEM XTENDEX CLASSIC 5/4 DECKING BOARD MATERIALS REQUIRED XTENDEX PRODUCTS - CLASSIC 5/4 DECKING BOARDS - HOLD DOWN S W/#6-1 S/S SCREWS - #8-1 S/S SCREWS - DIA. PLASTIC PLUGS - END CAPS OR G-TRIM - 1x6 OR 1x8 S GENERAL PRODUCTS - FRAMING MATERIAL (PT WOOD) - #8 x 3 S/S WOOD SCREWS TOOLS REQUIRED - CHOP/SKILL SAW - MEASURING TAPE & PENCIL - SCREW GUN W/BITS - 7/64 DIA. DRILL BIT - FRAMING SQUARE - LEVEL #1 NO-CORODE BIT #6-1 S/S SCREW XTENDEX HOLD-DOWN XTENDEX CLASSIC 5/4 DECKING BOARD XTENDEX CLASSIC 5/4 DECKING BOARD DECK & ASSEMBLY - SECTION 1
4 CLASSIC 5/4 DECKING SYSTEM 16 o/c 16 JOIST SPACING HOUSE SPAN CHART Use the CHART to the right as a guide to determine requirements for various deck sizes: - the number of boards (1 thru. 43 down the left), - the number of joists required, the dash/dot lines for 16 o/c, - the number of clips and screws required per length between boards, - for a total amount of board feet required, take the number of boards and multiply by the Nominal Deck Length. See decking dimensions below. NOTES: DESIGN LIVE LOAD MAXIMUM 100 PSF JOIST 16 O/C MAXIMUM FOR BOARDS PERPENDICULAR TO JOISTS JOIST 12 O/C MAXIMUM FOR BOARDS AT 45 DEG TO JOISTS NOMINAL DECK WIDTH BOARDS BOARDS 43 S 3 PER BOARD S 4 PER BOARD S 6 PER BOARD S 7 PER BOARD S 9 PER BOARD S 10 PER BOARD S 12 PER BOARD S 13 PER BOARD S 15 PER BOARD S 16 PER BOARD NOMINAL DECK LENGTH XTENDEX 5/4 DECKING DIMENSIONS NOTE: DIMENSIONS BELOW ARE BASED ON A SPACE BETWEEN DECKING BOARDS 5 EDGE TO EDGE (OF BOARD) 5 CENTER TO CENTER (OF SPACE/) 5 CENTER (OF SPACE) TO EDGE 5 EDGE TO EDGE OF NEXT BOARD SPACE / 2
5 CLASSIC 5/4 DECKING SYSTEM DECKING INSTALLATION INSTRUCTIONS #6-1 S/S SCREWS XTENDEX HOLD DOWN XTENDEX END CAP (OPTIONAL) XTENDEX 5/4 COMPOSITE DECKING #8-1 S/S DECK o.c. W/ PLASTIC CAP Note: Read carefully XTENDEX decking installation instructions before starting construction on your deck. Also, see Span Chart on page 2 for size of your deck and quantities of XTENDEX material required. 1. Lay the 1st decking board onto a deck at the house or at the rim joist and mark locations for all concealed fasteners above the ledger or rim joist spaced maximum 16 o.c. all along the board s length. Drill dia. hole through the upper wall of decking board for the screw access Then pre-drill 7/64 dia. pilot holes through the bottom wall for all fasteners. Use #8-1 S/S deck screws to fasten the 1st board to a ledger or joist. Then use dia. plastic plugs to plug the holes through the upper wall. 2. Then place XTENDEX HOLD DOWN S acting also as spacers against the side of the 1st board at each deck support or joist spaced not more than 16 o.c. and screw them down with #6-1 S/S fasteners. Do not tighten the screws fully yet. Based on your deck configuration identify location of fixed (pinned) connection using information on pages 13 to 18 in this guide and pin 1st decking board as per instructions. 3. Place the 2nd board tightly in position under the hold down clips against 1st board, install hold down clips against the 2nd board as per instruction in paragraph above & then tighten the hold down clip screws between 1st and 2nd board snug. NOTE: PROVIDE DIAGONAL BRACING FOR PRESSURE TREATED DECK SUBSTRUCTURE ON THE UNDERSIDE OF JOISTS PT WOOD (2x8) DECK SUBSTRUCTURE NOTE: DO NOT OVER TORQUE SCREWS INTO HOLD DOWN S. 4. Continue in the same manner with hold-down clip fastening towards the other end pinning each individual board as described in section 2. Fasten the last board again as per recommendation for the 1st board above. 5. Do not trim the boards individually. Once all boards are laid on a deck, check the ambient temperature at that time and refer to the expansion and contraction chart on page 10 or 11& 12 for expansion and contraction gap requirements for G-Trim or between ends of multiple board decking configuration. Then trim all boards at the same time. G-TRIM EDGING DETAILS - for finishing the sides and ends of your XTENDEX 5/4 Decking. IMPORTANT: Do not use G-trim for edging for steps due to a tripping hazard. 2X4 XTENDEX G-TRIM DIA. PLASTIC CAP XTENDEX 5/4 CLASSIC DECKING HOLD-DOWN 2X4 XTENDEX G-TRIM HOLD-DOWN XTENDEX 5/4 CLASSIC DECKING DIA. PLASTIC CAP #8-1 S/S DECK 16 O.C. (TYP.) 1x6 (1x8) XTENDEX #8-1 S/S DECK 16 O.C. (TYP.) FRAMING DIA. PLASTIC CAP #8-1 S/S DECK 16 O.C. (TYP.) 1x6 (1x8) XTENDEX FRAMING HEADER OR RIM JOIST HEADER OR RIM JOIST 3
6 SOLID BOARD DECKING XTENDEX ARCHITECTURAL 1x6 SOLID BOARD MATERIALS REQUIRED XTENDEX PRODUCTS - ARCHITECTURAL 1x6 SOLID DECKING BOARDS - HOLD DOWN S W/#6-1 S/S SCREWS - #8-1 S/S PINNING SCREWS - #8-2 S/S DECK SCREWS - G-TRIM - 1x6 OR 1x8 S GENERAL PRODUCTS - FRAMING MATERIAL (PT WOOD) - #8 x 3 S/S WOOD SCREWS TOOLS REQUIRED - CHOP/SKILL SAW - MEASURING TAPE & PENCIL - SCREW GUN W/BITS - 7/64 DIA. DRILL BIT W/COUNTERSINK - FRAMING SQUARE - LEVEL #1 NO-CORODE BIT #6-1 S/S SCREW XTENDEX HOLD-DOWN XTENDEX ARCHITECTURAL 1x6 DECKING BOARD XTENDEX ARCHITECTURAL 1x6 DECKING BOARD DECK & ASSEMBLY - SECTION 4
7 SOLID BOARD DECKING 16 o/c 16 JOIST SPACING HOUSE SPAN CHART Use the CHART to the right as a guide to determine requirements for various deck sizes: - the number of boards (1 thru. 44 down the left), - the number of joists required, the dash/dot lines for 16 o/c, - the number of clips and screws required per length between boards, - for a total amount of board feet required, take the number of boards and multiply by the Nominal Deck Length. See decking dimensions below. NOTES: DESIGN LIVE LOAD MAXIMUM 100 PSF JOIST 16 O/C MAXIMUM FOR BOARDS PERPENDICULAR TO JOISTS JOIST 12 O/C MAXIMUM FOR BOARDS AT 45 DEG TO JOISTS NOMINAL DECK WIDTH BOARDS 2 S 3 PER BOARD S 4 PER BOARD S 6 PER BOARD S 7 PER BOARD S 9 PER BOARD S 10 PER BOARD S 12 PER BOARD S 13 PER BOARD S 15 PER BOARD BOARDS S 16 PER BOARD NOMINAL DECK LENGTH XTENDEX ARCHITECRURAL 1X6 SOLID BOARD DIMENSIONS NOTE: DIMENSIONS BELOW ARE BASED ON A SPACE BETWEEN DECKING BOARDS 5 EDGE TO EDGE (OF BOARD) 5 CENTER TO CENTER (OF SPACE/) 5 CENTER (OF SPACE) TO EDGE 5 EDGE TO EDGE OF NEXT BOARD SPACE / 5
8 #6-1 S/S SCREWS XTENDEX HOLD DOWN S XTENDEX 1x6 ARCHITECTURAL SOLID DECKING BOARD #8-2 S/S DECK o.c. SOLID BOARD DECKING DECKING INSTALLATION INSTRUCTIONS Note: Read carefully XTENDEX decking installation instructions before starting construction on your deck. Also, see Span Chart on page 5 for size of your deck and quantities of XTENDEX material required. 1. Lay the 1st decking board onto a deck at the house or at the rim joist and mark locations for all fasteners above the ledger or rim joist spaced maximum 16 o.c. all along the board s length. Pre-drill 7/64 dia. pilot holes through decking board for all fasteners. Use of countersink adapter is recommended for screw heads to be nicely flush with decking surface. Use #8-2 S/S deck screws to fasten the board to a ledger or joist. 2. Then place XTENDEX HOLD DOWN S acting also as spacers against the side of the 1st board at each deck support or joist spaced not more than 16 o.c. and screw them down with #6-1 S/S fasteners. Do not tighten the screws fully yet. Based on your deck configuration identify location of fixed (pinned) connection using information on pages 13 to 18 in this guide and pin 1st decking board as per instructions. 3. Place the 2nd board tightly in position under the hold down clips against 1st board, install hold down clips against the 2nd board as per instruction in paragraph above & then tighten the hold down clip screws between 1st and 2nd board snug. NOTE: DO NOT OVER TORQUE SCREWS INTO HOLD DOWN S. PT WOOD (2x8) DECK SUBSTRUCTURE G-TRIM EDGING DETAILS - for finishing the sides and ends of your XTENDEX 1 Solid Board Decking. IMPORTANT: Do not use G-trim for edging for steps due to a tripping hazard. 4. Continue in the same manner with hold-down clip fastening towards the other end pinning each individual board as described in section 2. Fasten the last board again as per recommendation for the 1st board above. 5. Do not trim the boards individually. Once all boards are laid on a deck, check the ambient temperature at that time and refer to the expansion and contraction chart on page 10 or 11 & 12 for expansion and contraction gap requirements for G-Trim or between ends of multiple board decking configuration. Then trim all boards at the same time. 2X4 XTENDEX G-TRIM OPTIONAL DIA. PLASTIC CAP #8-2 S/S DECK 16 O.C. (TYP.) XTENDEX 1x6 ARCHITECTURAL DECKING HOLD-DOWN 2X4 XTENDEX G-TRIM OPTIONAL DIA. PLASTIC CAP HOLD-DOWN XTENDEX 1x6 ARCHITECTURAL DECKING #8-1 S/S DECK 16 O.C. (TYP.) FRAMING #8-1 S/S DECK 16 O.C. (TYP.) FRAMING 1x6 (1x8) XTENDEX 1x6 (1x8) XTENDEX HEADER OR RIM JOIST HEADER OR RIM JOIST 6
9 SOLID BOARD DECKING XTENDEX TRADITIONAL 1x6 SOLID BOARD MATERIALS REQUIRED XTENDEX PRODUCTS - TRADITIONAL 1x6 SOLID DECKING BOARDS - #8-2 S/S DECK SCREWS - G-TRIM - 1x6 OR 1x8 S GENERAL PRODUCTS - FRAMING MATERIAL (PT WOOD) - #8 x 3 S/S WOOD SCREWS TOOLS REQUIRED - CHOP/SKILL SAW - MEASURING TAPE & PENCIL - SCREW GUN W/BITS - 7/64 DIA. DRILL BIT W/ COUNTERSINK - FRAMING SQUARE - LEVEL - #8-2 S/S DECK 16 O.C. MAX. #8-2 S/S DECK 16 O.C. MAX. XTENDEX TRADITIONAL 1x6 DECKING BOARD XTENDEX TRADITIONAL 1x6 DECKING BOARD 16 O.C. 16 O.C. DECK & SCREWS ASSEMBLY - SECTION 7
10 SOLID BOARD DECKING 16 o/c 16 JOIST SPACING HOUSE SPAN CHART Use the CHART to the right as a guide to determine requirements for various deck sizes: - the number of boards (1 thru. 44 down the left), - the number of joists required, the dash/dot lines for 16 o/c, - the number of screws required per length of boards, - for a total amount of board feet required, take the number of boards and multiply by the Nominal Deck Length. See decking dimensions below. NOTES: DESIGN LIVE LOAD MAXIMUM 100 PSF JOIST 16 O/C MAXIMUM FOR BOARDS PERPENDICULAR TO JOISTS JOIST 12 O/C MAXIMUM FOR BOARDS AT 45 DEG TO JOISTS NOMINAL DECK WIDTH BOARDS 2 6 SCREWS PER BOARD SCREWS PER BOARD SCREWS PER BOARD SCREWS PER BOARD SCREWS PER BOARD SCREWS PER BOARD SCREWS PER BOARD SCREWS PER BOARD SCREWS PER BOARD BOARDS 32 SCREWS PER BOARD NOMINAL DECK LENGTH XTENDEX TRADITIONAL 1X6 SOLID BOARD DIMENSIONS NOTE: DIMENSIONS BELOW ARE BASED ON A SPACE BETWEEN DECKING BOARDS MIN. 1 5 EDGE TO EDGE (OF BOARD) 5 CENTER TO CENTER (OF SPACE/) 5 CENTER (OF SPACE) TO EDGE 5 EDGE TO EDGE OF NEXT BOARD 16 O.C. SPACE REQUIRED 8
11 SOLID BOARD DECKING 2 x SCREWS PER BOARD PER SUPPORT (JOIST) XTENDEX 1x6 TRADITIONAL SOLID DECKING BOARD #8-2 S/S DECK o.c. PT WOOD (2x8) DECK SUBSTRUCTURE DECKING INSTALLATION INSTRUCTIONS Note: Read carefully XTENDEX decking installation instructions before starting construction on your deck. Also, see Span Chart on page 8 for size of your deck and quantities of XTENDEX material required. 1. Lay the 1st decking board onto a deck at the house or at the rim joist and mark locations for all fasteners above the ledger or rim joist spaced maximum 16 o.c. all along the board s length. Pre-drill 7/64 dia. pilot holes through decking board for all fasteners. Use of countersink adapter is recommended for screw heads to be nicely flush with decking surface. Use 2 x #8-2 S/S deck screws per support to fasten the board to a ledger or joist. NOTE: DO NOT OVER TORQUE SCREWS INTO DECKING BOARDS. SCREW HEADS TO BE FLUSH WITH DECK SURFACE. 2. Then place spacers between 1st and 2nd board and fasten the 2nd board to substructure with 2 x #8-2 S/S deck screws per support same way as described above and then continue in the same manner towards the other end board by board. 3. Pinning of boards as prescribed for hold-down clip fastening system is not required. Maximum length of single board shall not exceed 16. In multiple board decking configuration refer to expansion and contraction chart on page 10 or 11 for expansion and contraction gap required between two adjacent board which is based on ambient temperature at the time of installation. 4. Do not trim the boards individually. Once all boards are laid on a deck, check the ambient temperature at that time and refer again to the expansion and contraction chart on page 12 for expansion and contraction gap requirements for G-Trim. Then trim all boards at the same time. G-Trim installation is optional. G-TRIM EDGING DETAILS - for finishing the sides and ends of your XTENDEX 1 Solid Board Decking. IMPORTANT: Do not use G-trim for edging for steps due to a tripping hazard. 2 x #8-2 S/S DECK 16 O.C. (TYP.) XTENDEX 1x6 TRADITIONAL DECKING 2 x #8-2 S/S DECK 16 O.C. (TYP.) XTENDEX 1x6 TRADITIONAL DECKING 2X4 XTENDEX G-TRIM OPTIONAL DIA. PLASTIC CAP 2X4 XTENDEX G-TRIM OPTIONAL DIA. PLASTIC CAP #8-1 S/S DECK 16 O.C. (TYP.) FRAMING #8-1 S/S DECK 16 O.C. (TYP.) FRAMING 1x6 (1x8) XTENDEX 1x6 (1x8) XTENDEX HEADER OR RIM JOIST HEADER OR RIM JOIST 9
12 THERMAL EXPANSION CHART THERMAL EXPANSION AND CONTRACTION (CELSIUS) All wood plastic composites are subject to expansion and contraction caused by temperature change and moisture intake. Use of the following chart will help you to determine the gap or space required for the deck installation. Length of deck L is referred to as one continuous decking board. Where more than one board is used to cover the deck s length, allow for a gap equal to the sum of expansions of all individual boards. To control the direction of expansion and contraction fixed or pinned attachment of the deck board to the joist at specified location is required. For decks up to 20 feet long, decks can be built with one board length only. In this case the fixed connection will be done in the middle of the board to allow for expansion and contraction from the center towards the board ends in both directions. Coefficient of Thermal Expansion C = (Inch/inch per degree Celsius) Examples: Ex. 1 Deck 16 in length Ex. 2 Deck 32 in Length. a) Full length deck board a) Two 16 boards used. b) Installed at 15 deg. C b) Installed at 15 deg. C. L is 16 & temp. Is 15 deg. C Thermal expansion = total L is 16 x2 & temp. is 15 deg. C Thermal expansion = += total Consult the table below for total gap required to compensate for thermal expansion and expansion caused by moisture intake. Refer to the ambient temperature on the day of installation and the total length of your deck. Trim the decking boards all at once. Cut only when all boards are installed and temperature is even throughout the deck surface. Maximum Temperature 45 deg. C Length of Deck L Approximate Ambient Temperature On Day of Installation (degree C) / / / / / / /16 1/16 In addition to thermal expansion expansion per 10 of board length due to the moisture intake has been considered in the table above. 10
13 THERMAL EXPANSION CHART THERMAL EXPANSION AND CONTRACTION (FAHRENHEIT) All wood plastic composites are subject to expansion and contraction caused by temperature change and moisture intake. Use of the following chart will help you to determine the gap or space required for the deck installation. Length of deck L is referred to as one continuous decking board. Where more than one board is used to cover the deck s length, allow for a gap equal to the sum of expansions of all individual boards. To control the direction of expansion and contraction fixed or pinned attachment of the deck board to the joist at specified location is required. For decks up to 20 feet long, decks can be built with one board length only. In this case the fixed connection will be done in the middle of the board to allow for expansion and contraction from the center towards the board ends in both directions. Coefficient of Thermal Expansion C = (Inch/inch per degree Fahrenheit) Examples: Ex. 1 Deck 16 in length Ex. 2 Deck 32 in Length. a) Full length deck board a) Two 16 boards used. b) Installed at 59 deg. F b) Installed at 59 deg. F L is 16 & temp. Is 59 deg. F Thermal expansion = total L is 16 x2 & temp. is 59 deg. F Thermal expansion = += total Consult the table below for total gap required to compensate for thermal expansion and expansion caused by moisture intake. Refer to the ambient temperature on the day of installation and the total length of your deck. Trim the decking boards all at once. Cut only when all boards are installed and temperature is even throughout the deck surface. Maximum Temperature 113 deg. F Length of Deck L Approximate Ambient Temperature On Day of Installation (degree F) / / / / / / /16 1/16 In addition to thermal expansion expansion per 10 of board length due to the moisture intake has been considered in the table above. 11
14 EXPANSION AND CONTRACTION 2x4 G-TRIM EDGING BOARD 1x6 SKIRTING BOARD INSTALLATION INSTRUCTIONS: 1. INSTALL DECKING BOARDS THROUGHOUT YOUR DECK. A FROM PINNED CONNECTION 2. DETERMINE THE OVERHANG VALUE "A" FROM TABLE 1 BELOW. "A" VARIES WITH THE DECK LENGTH AND THE AMBIENT TEMPERATURE AT THE TIME OF INSTALLATION. 3. THEN TRIM THE ENDS ALL AT THE SAME TIME. HOLD-DOWN 5/4" OR 1 DECKING 4. AT LAST INSTALL THE G-TRIM EDGING. TABLE 1 AMBIENT TEMPERATURE "A" 35 F 2 C 0.25" O.C. 75 F 110 F 24 C 43 C 0.50" 0.75" NOTE: IMPORTANT: DO NOT USE G-TRIM FOR EDGING FOR STEPS OR STAIRS DUE TO A TRIPPING HAZARD. TABLE 1 HAS BEEN DEVELOPED FOR MAXIMUM 40 FEET LONG DECK CONSISTING OF TWO 20 FEET LONG DECKING BOARDS END BUTTED AND BOTH PINNED (FIX CONNECTED TO SUBSTRUCTURE) AT BUTT JOIN. TO DETERMINE "A" VALUE FOR ANY OTHER LENGTH LESS THAN 40 FEET CONSULT THE MORE DETAILED DATA IN THERMAL EXPANSION AND CONTRACTION TABLE IN THIS GUIDE. CONSULT FACTORY ON SOLUTIONS WITH DECKS OVER 40 FEET LONG. G-TRIM EDGING DETAIL 12
15 EXPANSION AND CONTRACTION * REFER TO PAGE 12 FOR DIMENSION A HOLD-DOWN 2x4 G-TRIM EDGING BOARD A 1x6 XTENDEX SEE DETAILS ON PAGES 3, 6 & 9 IMPORTANT: DO NOT USE G-TRIM FOR EDGING FOR STEPS OR STAIRS DUE TO A TRIPPING HAZARD. NOTE: PRE-DRILL 7/64 DIA. PILOT HOLE FOR PINNING SCREWS AT 45 DEG (TYPICAL) FIXED PINNED CONNECTION AT BOARD'S MIDPOINT SEE DETAIL ON PAGE 16 2x8 PRESSURE TREATED WOOD SUBSTRUCTURE W/ DIAGONAL BRACING DECK BOARD UP TO 20' LONG NOTES: PROVIDE PINNED CONNECTION BETWEEN DECKING BOARD AND SUBSTRUCTURE AT LOCATIONS SHOWN ABOVE TO CONTROL EXPANSION AND CONTRACTION IN DESIRED ONE CONTINUOUS DECKING BOARD UP TO 20' LONG (NO BUTT JOINT) 5/4" OR 1 DECKING BOARD * REFER TO PAGE 12 FOR DIMENSION A A 2x4 G-TRIM EDGING BOARD 1x6 XTENDEX 13
16 EXPANSION AND CONTRACTION * REFER TO PAGE 12 FOR DIMENSION A HOLD-DOWN 2x4 G-TRIM EDGING BOARD A 1x6 XTENDEX IMPORTANT: DO NOT USE G-TRIM FOR EDGING FOR STEPS OR STAIRS DUE TO A TRIPPING HAZARD. NOTE: PRE-DRILL 7/64 DIA. PILOT HOLE FOR PINNING SCREWS AT 45 DEG (TYPICAL) BUTT JOINT CENTERED OVER DOUBLE JOIST - NO GAP REQUIRED 5/4" OR 1 DECKING BOARD PINNED CONNECTION AT EACH BOARD END 2x8 PRESSURE TREATED WOOD SUBSTRUCTURE W/ DIAGONAL BRACING SEE DETAILS ON PAGE 16 & 17 PROVIDE DOUBLE JOIST OR NAILER AT BUTT JOINT DECK BOARD UP TO 20' LONG DECK BOARD UP TO 20' LONG DECK LENGTH UP TO 40' LONG NOTES: PROVIDE PINNED CONNECTION BETWEEN DECKING BOARD AND SUBSTRUCTURE AT LOCATIONS SHOWN ABOVE TO CONTROL EXPANSION AND CONTRACTION IN DESIRED TWO CONTINUOUS DECKING BOARDS UP TO 20' LONG EACH (ONE BUTT JOINT) * REFER TO PAGE 12 FOR DIMENSION A A 2x4 G-TRIM EDGING BOARD 1x6 XTENDEX 14
17 EXPANSION AND CONTRACTION * REFER TO PAGE 12 FOR DIMENSION A 2x4 G-TRIM EDGING BOARD A 1x6 XTENDEX IMPORTANT: DO NOT USE G-TRIM FOR EDGING FOR STEPS OR STAIRS DUE TO A TRIPPING HAZARD. NOTE: PRE-DRILL 7/64 DIA. PILOT HOLE FOR PINNING SCREWS AT 45 DEG (TYPICAL) PROVIDE PINNED CONNECTION AT EACH BOARD END 5/4" OR 1 DECKING BOARD 2x8 PRESSURE TREATED WOOD SUBSTRUCTURE W/ DIAGONAL BRACING SEE DETAIL ON PAGE 18 PROVIDE DOUBLE JOIST & BLOCKING W/ XTENDEX 2x4 BREAKER BOARD DECK BOARD UP TO 20' LONG DECK BOARD UP TO 20' LONG 1 9/16" GAP DECK LENGTH UP TO 40 LONG NOTES: PROVIDE FIXED CONNECTION BETWEEN DECKING BOARD AND SUBSTRUCTURE AT LOCATIONS SHOWN ABOVE TO CONTROL EXPANSION AND CONTRACTION IN DESIRED TWO CONTINUOUS DECKING BOARDS UP TO 20' LONG WITH XTENDEX 2x4 BREAKER BOARD * REFER TO PAGE 12 FOR DIMENSION A A 2x4 G-TRIM EDGING BOARD 1x6 XTENDEX 15
18 EXPANSION AND CONTRACTION * REFER TO PAGE 12 FOR DIMENSION A 2x4 G-TRIM EDGING BOARD 1x6 XTENDEX MID-BOARD PINNED CONNECTION NOTE: PRE-DRILL 7/64 DIA. PILOT HOLE FOR PINNING SCREWS AT 45 DEG (TYPICAL) A XTENDEX HOLD-DOWN #8-1 S/S WOOD SCREW 5/4" OR 1 DECKING BOARD "1" XTENDEX 45 DEG 5/4" OR 1 DECKING BOARD #8-1 DECK 45 FIXED CONNECTION 2x8 PRESSURE TREATED WOOD SUBSTRUCTURE "1" 2x8 WOOD JOIST SIDE VIEW SECTION "1-1" EDGING DETAIL FIXED CONNECTION DETAIL EXPANSION AND CONTRACTION DETAILS 16
19 EXPANSION AND CONTRACTION NOTE: PRE-DRILL 7/64 DIA. PILOT HOLE FOR PINNING SCREWS AT 45 DEG (TYPICAL) BUTT JOINT CENTERED OVER DOUBLE JOIST 5/4" DECKING BOARD HOLD-DOWN 1/16 GAP FIXED CONNECTION AT EACH BOARD END 5/4" DECKING BOARD PROVIDE DOUBLE JOIST AT BUTT JOINT SECTION DETAIL USE #8-2" LONG WOOD 45 FOR FIXED CONNECTION BUTT JOINT DETAILS 1/16 GAP BUTT JOINT 1/16 GAP FIXED CONNECTION AT EACH BOARD END DOUBLE WOOD JOIST PLAN VIEW 17
20 EXPANSION AND CONTRACTION 1/16 GAP 1/16 GAP PROVIDE PINNED CONNECTION AT EACH BOARD END XTENDEX 2x4 BREAKER BOARD XTENDEX 2x4 BREAKER BOARD 1/16 GAP HOLD-DOWN HOLD-DOWN HOLD-DOWN HOLD-DOWN 5/4" XTENDEX BOARD #8-2" DECK XTENDEX 5/4" OR 1 DECKING XTENDEX 5/4" OR 1 DECKING 32" O.C. STAGGERED 2x4 PT WOOD BLOCKING #8-2 1/2" DECK 32" O.C. STAGGERED JOIST DOUBLE JOIST W/ 2x4 BLOCKING APPROX. 1 1/2" GAP APPROX. 1 1/2" NOTE: PRE-DRILL 7/64 DIA. PILOT HOLE FOR PINNING SCREWS AT 45 DEG (TYPICAL) PLAN VIEW SECTION BREAKER BOARD BUTT JOINT DETAIL 18
21 EXPANSION AND CONTRACTION NOTE: PROVIDE PINNED CONNECTION AT BOARD S MIDPOINT PRE-DRILL 7/64 DIA. PILOT HOLE FOR PINNING SCREWS AT 45 DEG (TYPICAL) XTENDEX G-TRIM BACK-TO-BACK ALLOW GAP FOR EXPANSION REFER TO PAGE 12 XTENDEX G-TRIM BACK-TO-BACK 5/4" OR 1 XTENDEX DECKING HOLD-DOWN HOLD-DOWN HOLD-DOWN HOLD-DOWN 2x4 PT WOOD BLOCKINGS #8-2" DECK 32" O.C. STAGGERED XTENDEX 5/4" OR 1 DECKING XTENDEX 5/4" OR 1 DECKING JOIST #8-2 1/2" DECK 32" O.C. STAGGERED 2x8 PT JOISTS W/ WOOD BLOCKING APPROX. 3 GAP APPROX. 2 x 1 1/2" SECTION PLAN VIEW DOUBLE G-TRIM DECK BREAKER JOINT DETAIL 19
DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS
DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS 866.729.2378 MOISTURESHIELD.COM limited lifetime warranty 866.729.2378 W W W.MOISTURESHIELD.COM Welcome To The Even Greater Outdoors. Congratulations
More informationChapter 7. Roof Framing
Chapter 7. Roof Framing 7.1 ROOFING PREP WORK 7.2 INSTALLING ROOF TRUSSES 7.3 INSTALLING PORCH TRUSSES 7.4 SHEATHING ROOF 7.5 INSTALLING SUB-FASCIA 7.6 BUILDING AND INSTALLING SCUTTLE BOX 7.7 INSTALLING
More informationThe following are details of the code requirements of the 2015 International Residential Code for single-story decks.
The following are details of the code requirements of the 2015 International Residential Code for single-story decks. The 2015 International Residential Code Section R507 contains additional information
More informationATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 08/09/2014 Issued: 08/09/2013 Visit www.ati-es.com for current status Revised: 08/12/2013 Page 1 of
More informationHORIZON AND SYMMETRY CLADDING INSTALLATION INSTRUCTIONS
HORIZON AND SYMMETRY CLADDING INSTALLATION INSTRUCTIONS 1-800-573-8841 FIBERONCLADDING.COM GENERAL GUIDELINES 1. Only Fiberon Horizon and Symmetry products are approved for use in cladding and screen façade
More informationResidential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT
Residential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT 507-444-4370 www.ci.owatonna.mn.us This handout is intended only as a guide and is based in part on the 2007
More informationPinkWood Ltd. Revised September 29, 2017
Fire-Rated Assemblies PR-S315 PinkWood Ltd. Revised September 29, 2017 Products: Series I-Joists PinkWood Ltd., 5929 6 th St. NE, Calgary, Alberta, Canada T2K 5R5 (403) 279-3700 www.pinkwood.ca 1. Basis
More informationAnchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi
STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel
More informationEP Decking Inc. Installation Guide
EP Decking Inc. Installation Guide www.epdecking.com EP Decking Inc. Installation Guide Calculating Material Requirements To calculate how many EP Decking pieces you will need, start by calculating the
More informationRev. 07 8/15 Please Read Disclaimers:
FiberCorr panels Guidelines 6005.FC Rev. 07 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to help prevent any problems
More informationRESIDENTIAL WOOD DECK CONSTRUCTION GUIDE
RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE Based on The 2009 Michigan Residential Code Revised September 25, 2014 Wood Deck Construction in accordance with this guide is acceptable in the following Michigan
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3771 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 06 00
More information138 H-STUD AREA SEPARATION WALL SYSTEM
H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic fashion by the results of this actual townhouse fire in which the two-hour fire-rated
More informationLP OSB Sheathing & Structural 1 Sheathing
Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More informationAppendix D. -Weyerhaeuser Fire Rated Assembly Listings-
Appendix D -Weyerhaeuser Fire Rated Assembly Listings- Table of Contents Assembly Description Reference Standard/Criteria FJ-1 TJI Joist 1 hour fire resistance rated floor and roof assembly. ASTM-E119
More informationCEILING & WALL SYSTEMS
CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.
More informationAssemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance
Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation
More informationGeneral Requirements Yes N/A 1. Is the designer qualified for the proposed work?
DECKS BUILDING PERMIT REQUIREMENTS May 216 Below is a checklist outlining the requirements to obtain a building permit to construct a deck for a single detached, semi-detached, duplex or townhouse dwelling
More informationRESIDENTIAL WOOD DECK CONSTRUCTION GUIDE
RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE Based on the 2015 Michigan Residential Code Revised May 17, 2016 The Following Organizations Support the use of this Guide: The details in this document apply to
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1225 Reissued 10/2017 This report is subject to renewal 10/2019. DIVISION: 06 00
More informationGroundTrac. Installation Manual
APPLICATION: The GroundTrac system is designed with a minimum amount of installed footings at greatly reduced labor. The system integrates with ordinary 1-1/2 schedule #40 galvanized water pipe. This ground
More informationFig Beam Clamp Retaining Strap (B-Line B3367)
Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized
More informationThe GlasRoc Shaftliner Type X advantage...
C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where
More informationTemporary Construction Loads Over I-Joist Roofs And Floors
T E C H N I C A L N O T E Temporary Construction Loads Over I-Joist Roofs And Floors Number J735C July 2012 During construction of light-frame structures it is common to see relatively heavy loads placed
More informationDecking Installation Instructions. Updated 12/16 for: Horizon, Symmetry, Paramount, Protect Advantage, Good Life, Relax, and Sanctuary
Decking 07 Installation Instructions Updated /6 for: Horizon, Symmetry, Paramount, Protect Advantage, Good Life, Relax, and Sanctuary Manufactured by fiberondecking.com 800.573.884 Decking installation
More information1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.
WOOD FLOORING GENERAL INFORMATION 1.1 This section applies to factory finished wood strip flooring. 1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards. 1.3
More informationInstallation Guide and Safety Manual
Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) REQUIRED FURRING CHANNEL REQUIRED FURRING CHANNEL* 1 4" 2 2" Minimum f" Gauge:...25 Gauge With Hemmed Edge (Do Not
More informationSHEAR BRACE. Featuring ilevel Shear Braces for Engineered and Prescriptive Applications iLevel8 (
WALL SOLUTIONS SHEAR BRACE 2006 IBC/IRC Code Accepted* *Achieved code evaluation report recognition (ICC ES ESR-2652) for compliance with the 2006 IBC/IRC Featuring ilevel Braces for Engineered and Prescriptive
More informationThe better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................
More informationCode Compliance Research Report CCRR-0194
Code Compliance Research Report CCRR-0194 Issued: 09-16-2013 Renewal Due: 09-16-2018 Revised: 10-12-2017 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 05 23 Wood, Plastic, and Composite
More informationIntroducing TJ Insulated Structural Framing Components
#TJ-9009 SPECIFIER S GUIDE TJ INSULATED HEADERS, RIM BoaRD, AND CORNERS Introducing TJ Insulated Structural Framing Components Helps meet the 2011 Federal Energy Star Homes and 2009 International Energy
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (0) 3-87 (562) 699-03 www.icc-es.org ESR-23 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00 THERMAL
More informationFACT SHEET #2 DECK INFORMATION
Borough of Doylestown Building and Zoning Department 57 West Court Street, Doylestown, PA 18901 215.345.4140 FACT SHEET #2 DECK INFORMATION BACKGROUND The provisions of the PAUCC. ICC Property Maintenance
More informationSeries Silicone structural glazed. Installation Instructions
Series 5600 Silicone structural glazed Installation Instructions Part NO. Y306 May 2016 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines 3-4 II. Perimeter Applications. 5 III. Anchor Installation.
More informationHILLSBOROUGH TOWNSHIP CODE ENFORCEMENT
HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE
More informationShaftwall and Area Separation Wall Systems.
Shaftwall and Area Separation Wall Systems www.marinoware.com Marino\WARE S Fire Rated Wall Systems Quality that takes you to the top. Marino\WARE created its CT Shaftwall System, to be a flexible shaftwall
More informationSECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)
SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationRESIDENTIAL WOOD DECK CONSTRUCTION GUIDE
RESIDENTIAL WOOD DECK CONSTRUCTION Based on the GUIDE 2015 Michigan Residential Code Revised May 17, 2016 The following organizations support the use of this guide: The details in this document apply to
More informationLPI 56 Technical Guide
LPI 56 Technical Guide Floor & Roof Applications Product Specifications & Design Values 2 Floor Tables 3 Uniform Floor Load (PLF) Tables: Simple s 4 Uniform Floor Load (PLF) Tables: Continuous s 5 Uniform
More informationINSTALLATION GUIDE Sika SolarMount 1 Exposition East West
Exposition East West CONTENTS 1 Notes on the Sika SolarMount 1 system (Exposition East West) for PV solar arrays 3 2 Setting up on site 3 3 Required Tools for mounting Sika SolarMount 1 to Sika roofing
More informationTypical Deck Details
Typical Deck Details YOU CAN USE TO BUILD YOUR DECK (Valid for 2008, check for annual updates) Introduction...2 Lateral Support of Decks... 13 Obtaining Permits...2 Joist Hangers... 14 General Notes...2
More informationROOFING APPLICATION STANDARD (TAS) No. 102(A)-95
ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, CLIPPED, RIGID, ROOF SYSTEMS (For Methods of Mechanical Attachment Excluding Clips,
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2386 Reissued 04/2016 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL
More informationGold Bond BRAND Gypsum Sheathing
BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant
More informationExisting Hangar. Existing Hangar 3'-7" New Stairs. Handrail. Close in Opening Frame with 2x4's 25'-7" NEW OFFICE 1 19'-8" Field Verify All Dimensions
LABEL A1 A2 S1 S2 L1 L2 MISC. NOTES MECHANICAL, PLUMBING & ELECTRICAL SYSTEMS The Mechanical, Plumbing and Electrical subcontractors are responsible for compliance with all respective Codes affecting their
More informationPV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual
PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series
More informationZurn Z886. 6" Perma-Trench. Installation Instructions
Zurn Z886 6" Perma-Trench Installation Instructions Z886 Accessories 6" [152mm] Wide Trench Drain System Below are the components of the Z886 trench drain typical to an installation. Check your order to
More informationNATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction
Walls And Ceilings Single- And Double-Layer Construction 09 9 00/NGC Single-Layer Construction The single-layer construction system consists of a single layer of Gold Bond brand Gypsum Board applied to
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL
More informationResidential Wood Deck Design
Residential Wood Deck Design EARN 0.1 ICC Continuing Education Unit (CEU) and/or AIA/CES HSW 1 Learning Unit (LU) BCD303-A Residential Wood Deck Design Description: Deck and balcony collapses injure occupants
More informationCity of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)
City of Hughson Building Safety Division 7018 Pine Street Hughson, CA 95326 (209) 883-4054 RESIDENTIAL ATTACHED PATIO COVERS Patio covers are one story roofed structures not more than 12 feet above grade,
More informationCITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.
City of Fruitland Building Inspections 208 South Division Street Fruitland, Maryland 21826 410.548.2804 CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE GENERAL NOTES This design guide
More informationLEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued October 1, 2007 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair
More information2.2E Parallam PSL Deep Beam
#TJ-7001 SPECIFIER S GUIDE 2.2E Parallam PSL Deep Beam Featuring 20" 24" Deep Trus Joist Parallam PSL Beams Ideal for multi-family and light commercial applications Offers high strength and consistent
More informationInstallation Instructions
Installation Instructions Dynarail Safety Ladder System Corrosion Resistant Nonconductive Fire Retardant High Strength-To-Weight Ratio Long, Low Maintenance Life Meets OSHA, BOCA & Other Building Code
More informationStandards for Testing and Rating Shoring Equipment
ANSI/SSFI SH300-2007 American National Standard Standards for Testing and Rating Shoring Equipment Scaffolding, Shoring & Forming Institute, Inc. Sponsor: Scaffolding, Shoring & Forming Institute, Inc.
More informationPrescriptive Residential Wood Deck Construction Guide Based on the 2012 International Residential Code
Prescriptive Residential Wood Deck Construction Guide Based on the 2012 International Residential Code Where applicable, provisions and details contained in this document are based on the International
More informationBUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps
BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps City of Virginia Beach Building Permits & Inspections Updated 4/30/09 Table of Contents I. Introduction... 1 II. Tips
More informationBioPrism Solid Surface
Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.
More informationSuspension System Data Center Ceiling Solutions
Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"
More informationSection III Installation Guidelines & Methods Page Chapter 7 Parquet Installation 30 Chapter 8 Engineered Wood Flooring Installation 34 Chapter 9
Section III Installation Guidelines & Methods Page Chapter 7 Parquet Installation 30 Chapter 8 Engineered Wood Flooring Installation 34 Chapter 9 Solid Strip and Plank Flooring Installation 37 Chapter
More informationBasic Suspension Systems
CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system
More informationREPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3145 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 05 00 00 METALS SECTION:
More informationTITEN HD Heavy Duty Screw Anchor for Concrete & Masonry
TITEN HD Heavy Duty Screw Anchor for & Masonry The Titen HD is a patented, high-strength screw anchor for concrete and masonry. The self-undercutting, non-expansion characteristics of the Titen HD makes
More informationDIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: TEKNION LIMITED
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1598 Reissued 12/2017 This report is subject to renewal 12/2019. DIVISION: 10 00
More informationSECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board
SECTION 09260 GYPSUM WALLBOARD SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Gypsum board at new wall partitions or where indicated on drawings. 1.2 REFERENCED STANDARDS A. ASTM C36 - Gypsum Wallboard
More informationConsiderations for Outof-Plane. Design
Considerations for Outof-Plane Wall and Uplift Design WoodWorks Texas Workshops December, 2016 Overview Uplift Wall Design Wind Loads Wind loads acting on buildings are modeled as uniform surface loads.
More informationOptima Vector Plank. Installation Instructions. Ceiling
Ceiling Systems Between us, ideas become reality Optima Vector Plank Installation Instructions 1. GENERAL 1.1. Product Description The Vector products referenced in these instructions are made from fiberglass.
More informationVertigo Cladding Board
Installation guide Vertigo Cladding Board Geolam: a stunning alternative to wood cladding Vertigo is a composite wood cladding board requiring minimum maintenance. Durable and fade resistant, it will not
More informationNRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly
Introduction 2001 Company, contracted NRCC/IRC to evaluate and determine both the thermal resistance and air leakage characteristics of five roofing specimens under controlled laboratory conditions. The
More informationREPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00
More informationTSX Insulation for Exposed Use ROOF WALL SPECIALTY
Insulation for Exposed Use ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax TSX-8500 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam core bonded to
More information2.2E Parallam PSL Deep Beam
#TJ-7001 SPECIFIER S GUIDE 2.2E Parallam PSL Deep Beam Featuring 20" 24" Deep Trus Joist Parallam PSL Beams Ideal for multi-family and light commercial applications Offers high strength and consistent
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC RAILINGS SECTION: STRUCTURAL PLASTICS REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3947 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 06 00
More informationAxiom Building Perimeter System
Ceiling Systems Between us, ideas become reality Axiom Building Perimeter System Assembly and Installation Instructions 1 GENERAL 1.1 Description The Axiom Building Perimeter System (AXBPS) is a preengineered
More informationESR-1461 Reissued February 1, 2014 This report is subject to renewal March 1, 2015.
ICC-ES Evaluation Report www.icc-es.org (800) 43-6587 (56) 699-0543 ESR-46 Reissued February, 04 This report is subject to renewal March, 05. A Subsidiary of the International Code Council DIVISION: 06
More informationROOF MOUNT KIT OWNERS MANUAL
ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF
More informationTable R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment
City of Republic - Community Development Department Roof and Subfloor Sheathing Spans Revision Date: January 2017 Table R503.2.1.1(1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor
More informationDIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1812 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 09 00
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 2 6587 (562) 699 05 www.icc es.org ESR 2919 Reissued 11/2017 This report is subject to renewal 11/2019. DIVISION: 06 00 00 WOOD,
More informationContainer Installation Guide
Container Insulation Container Installation Guide Panels and Inserts The InSoFast CX Container panel and the Inserts are designed to fit most shipping containers. Containers have three types of corrugations:
More informationIron Woods Vanish Rain Screen System Pushing the Envelope
Iron Woods Vanish Rain Screen System Pushing the Envelope Timber Holdings Intl., makers of Iron Woods the leading brand of premium naturally durable hardwood decking and siding for over 30 years, is excited
More informationICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003
PFC-5804* Reissued February 1, 2003 ICBO Evaluation Service, Inc. 5360 Workman Mill Road, Whittier, California 90601 www.icboes.org Filing Category: DESIGN Wood PACIFIC WOODTECH CORPORATION PWI JOISTS
More informationSpeedTrace Roof & Gutter Pre-Assembled Self-Regulating Heating Cable
SpeedTrace Roof & Gutter Pre-Assembled Self-Regulating Heating Cable For Snow and Ice Melting on Roofs and in Gutters and Downspouts Instruction Manual Read and understand this entire manual before installing
More informationDwarf Wall Assembly Instructions. Including Important Safety Information to be read fully and understood before attempting assembly
Dwarf Wall Assembly Instructions Including Important Safety Information to be read fully and understood before attempting assembly Contents Important Information... 2 Health, Safety & Environmental...
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: LOUISIANA PACIFIC CORPORATION
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1305 Reissued 08/2016 This report is subject to renewal 08/2018. DIVISION: 06 00 00 WOOD, PLASTICS
More informationREPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (00) 423-657 (562) 699-0543 www.icc-es.org ESR-3090 Issued 06/2017 This report is subject to renewal 06/2019. DIVISION: 06 00 00 WOOD, PLASTICS
More informationModular Wood Framing Goes Vertical
Modular Wood Framing Goes Vertical By: Troy Bean, P.E., S.E. DCI Engineers January 2013 The Wood Products Council is a Registered Provider with. Credit(s) earned on completion of this program will be reported
More informationEvolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.
Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical
More informationDuracast Pressure Plate Installation Instructions
July 2015 EFCO CORPORATION 7/2015 PART NO. YW45 1 TABLE OF CONTENTS SECTION S-5600 / S-5900 DURACAST PRESSURE PLATE PAGE I. General Notes and Guidelines. 3-4 II. Glazing Preparation & Installation... 5
More informationInstallation Procedure
Installation Procedure Information provided herein, including but not limited to, any drawing, design, photograph, graphic, or statement(s) ("Materials") are proprietary and the property of Watson Bowman
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3462 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00
More informationCode Compliance Research Report CCRR-0101
Code Compliance Research Report CCRR-0101 Issue Date: 07-31-2017 Renewal Date: 05-19-2018 DIVISION: 06 00 00 WOOD, PLASTICS, AND COMPOSITES Section: 06 50 00 Structural Plastics Section: 06 53 00 Plastic
More informationDIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2497 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 06 00
More informationTrusted ICC ES APA TH STREET. Conformity! subject of the
0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 42 687 (62) 699 04 www.icc es.orgg ESR 286 Reissued 07/207 This report is subject to renewal 07/209. DIVISION: 06 00 00 WOOD, PLASTICS
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3340 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL
More informationVisit our Website at E-Z Taping System, Inc. P.O. Box Green Bay, Wi Call: (800) Fax: (920)
Visit our Website at www.e-ztape.com E-Z Taping System, Inc. P.O. Box 11263 Green Bay, Wi 54307 Call: (800) 721-8273 Fax: (920) 569-4936 E-Z Taping System, Inc. P.O. Box 11263 Green Bay, Wi 54307 Call:
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2218 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00
More informationREPORT HOLDER: HOMELAND VINYL PRODUCTS, INC PINSON VALLEY PARKWAY BIRMINGHAM, ALABAMA EVALUATION SUBJECT:
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1657 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 06 00
More information