PHOTOGRAPHS. Project Number: OUTDOOR BACKGROUND SOIL GAS PORT INSTALL
|
|
- Sharlene Alexander
- 6 years ago
- Views:
Transcription
1 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA OUTDOOR BACKGROUND Photograph 9. Outdoor background air sampling at the Living Center, November SOIL GAS PORT INSTALL Photograph 10. Installed soil gas sampling port outside the Fire Station, November R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
2 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 11. Installed soil gas sampling port outside the Fire Station, November Photograph 12. Installing a soil gas sampling port outside the residence at 304 N 1st Avenue, November R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
3 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 13. Installed soil gas sampling port outside the residence at 322 N 1st Avenue, November SOIL GAS SAMPLING Photograph 14. Soil gas sampling setup, November R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
4 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 15. Soil gas sampling at the Fire Station, November SUBSLAB Photograph 16. Subslab port installed at 305 N Main Avenue, November R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
5 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 17. Subslab sampling at the Post Office, November Photograph 18. Installed subslab port in the interrogation room of the Police Department, November R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
6 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 19. Subslab sampling setup, November Photograph 20. Installed subslab sampling port at the Ridgefield Community Center, July R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
7 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 21. Foundational cracks in the walls of the basement at 305 N 1st Avenue, July Photograph 22. Gap between the first and second foundational slabs in the basement of 305 N 1st Avenue, July R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
8 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 23. Skylights with roof vents in second floor of 305 N 1st Avenue, July Photograph 24. Indoor air sampling on the main floor of 305 N 1st Avenue, July R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
9 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 25. Subslab sampling at the Community Center, July Photograph 26. Installation of soil gas sampling port at 305 N 1st Avenue, July R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
10 PHOTOGRAPHS Project Name: Former Park Laundry Site Project Number: Location: Ridgefield, WA Photograph 27. Installed soil gas sampling port at 305 N 1st Avenue, July Photograph 28. Soil gas sampling at 304 N 1st Avenue, July R:\ Stoel Rives\Report\03_ Vapor Intrusion Assessment Report\Appendices\Appendix B, Field Data Summary\Park Laundry Photo Array.docx
11 APPENDIX C CONCEPTUAL SITE MODELS
12 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Clark County Fire and Rescue.mxd WIND EFFECTSÀ Concrete Slab Foundation Proximity Monitoring Well Data: MW01 PCE Concentration: 8.38 ug/l (April 2012) 9.67 ug/l (June 2013) TCE Concentration: U ug/l (March 2012) U ug/l (June 2013) Depth to Groundwater: 3.11 ft (March 2012) 6.12 ft (July 2013) Utility Stub POTENTIAL SOIL VAPOR Building Characteristics: Date of Construction: 1940 Material of Construction: Concrete Type of Foundation: Concrete Slab Heating System: Electric Wall/Baseboard Roof Vents: No ELECTRIC WALL/ BASEBOARD HEATING SILTY SAND SHALLOW WATER BEARING ZONE CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Clark County Fire & Rescue Station N 3rd Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Fire Truck Parking Bay Office Kitchen Floorplan 1st Floor > 2nd Floor > Fire Truck Parking Bay Living = Indoor Air Sample Location > = Subslab Sample Location Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. >
13 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Community Center.mxd Concrete Slab Foundation WIND EFFECTSÀ Proximity Monitoring Well Data: MW05 PCE Concentration: 1,520 ug/l (April 2012) 1,790 J ug/l (June 2013) TCE Concentration: 2.22 ug/l (March 2012) 2.7 ug/l (June 2013) Depth to Groundwater: 6.19 ft (March 2012) 8.88 ft (July 2013) (UNOCCUPIED SPACE) Roof Vents Floor Drain POTENTIAL SOIL VAPOR Heating/Cooling Furnace/Fan MW06 PCE Concentration: 4.03 ug/l (April 2012) 3.92 ug/l (June 2013) TCE Concentration: 11.1 ug/l (March 2012) 6.61 ug/l (June 2013) Depth to Groundwater: 7.45 ft (March 2012) 8.9 ft (July 2013) SILTY SAND SHALLOW WATER BEARING ZONE CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Ridgefield Community Center 210 N Main Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Front Room Library Floorplan Closet Closet Bath > Office Building Characteristics: Date of Construction: 1993 Material of Construction: Wood Type of Foundation: Concrete Slab Heating System: /Heat Pump Roof Vents: Yes Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. Back Room > Kitchen Closet = Indoor Air Sample Location > = Subslab Sample Location
14 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Police Department.mxd Concrete Slab Foundation WIND EFFECTSÀ Proximity Monitoring Well Data: MW01 PCE Concentration: 8.38 ug/l (April 2012) 9.67 ug/l (June 2013) TCE Concentration: U ug/l (March 2012) U ug/l (June 2013) Depth to Groundwater: 3.11 ft (March 2012) 6.12 ft (July 2013) MW02 PCE Concentration: 0.88 J ug/l (April 2012) J ug/l (June 2013) TCE Concentration: U ug/l (March 2012) U ug/l (June 2013) Depth to Groundwater: 1.6 ft (March 2012) 7.11 ft (July 2013) Heating/Cooling Furnace/Fan POTENTIAL SOIL VAPOR Roof Vents Building Characteristics: Date of Construction: 2001 Material of Construction: Wood Type of Foundation: Concrete Slab Heating System: /Central Air System Roof Vents: Yes SILTY SAND SHALLOW WATER BEARING ZONE CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Ridgefield Police Department 116 N Main Ave Entry Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Front Office Office Floorplan > > Office Restrooms = Indoor Air Sample Location > = Subslab Sample Location Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. > Closet
15 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/16/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Post Office.mxd Concrete Slab Foundation WIND EFFECTSÀ Proximity Monitoring Well Data: MW04 PCE Concentration: 63.6 ug/l (April 2012) 29.2 ug/l (June 2013) TCE Concentration: 3.83 ug/l (March 2012) U ug/l (June 2013) Depth to Groundwater: 3.18 ft (March 2012) 7.22 ft (July 2013) MW05 PCE Concentration: 1,520 ug/l (April 2012) 1,790 J ug/l (June 2013) TCE Concentration: 2.22 ug/l (March 2012) 2.70 ug/l (June 2013) Depth to Groundwater: 6.19 ft (March 2012) 8.88 ft (July 2013) Heating/Cooling Furnace/Fan Floor Drains Roof Vents (UNOCCUPIED SPACE) POTENTIAL SOIL VAPOR Building Characteristics: Date of Construction: 1999 Material of Construction: Wood Type of Foundation: Concrete Slab Heating System: /Central Air Conditioning Roof Vents: Yes SILTY SAND SHALLOW WATER BEARING ZONE CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Ridgefield Post Office N Main Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Custodial Room Electrical Room > Floorplan > Office = Indoor Air Sample Location > = Subslab Sample Location Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. > >
16 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Residence 304 N 1st Ave.mxd WIND EFFECTSÀ Crawlspace with Dirt Floor Proximity Monitoring Well Data: MW13 PCE Concentration: 447 ug/l (April 2012) 114 ug/l (June 2013) TCE Concentration: 65.4 ug/l (March 2012) 21 ug/l (June 2013) Depth to Groundwater: 6 ft (March 2012) 8.72 ft (July 2013) Through Wall Mounted Heater/ Cooling Unit POTENTIAL SOIL VAPOR Through Wall Mounted Heater/ Cooling Unit Building Characteristics: Date of Construction: 1920 Material of Construction: Wood Type of Foundation: Crawlspace with Concrete Floor Heating System: Electric Wall/Baseboard Roof Vents: No SILTY SAND SHALLOW WATER BEARING ZONE Crawlspace Airvents (open seasonally) CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Private Residence 304 N 1st Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Kitchen Floorplan Laundry Office Bath Crawlspace Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. Living = Indoor Air Sample Location
17 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/24/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Residence 305 N 1st Ave.mxd WIND EFFECTS À Full Basement (concrete floor) Foundation Cracks Heating/Cooling Furnace/Fan Proximity Monitoring Well Data: MW13 PCE Concentration: 447 ug/l (April 2012) 114 ug/l (June 2013) TCE Concentration: 65.4 ug/l (March 2012) 21 ug/l (June 2013) Depth to Groundwater: 6 ft (March 2012) 8.72 ft (July 2013) Skylights POTENTIAL SOIL VAPOR Building Characteristics: Date of Construction: N/A Material of Construction: N/A Type of Foundation: Crawlspace with Concrete Floor Heating System:, Wood Stove Roof Vents: Yes (Skylights can be opened) Wood Stove SILTY SAND SHALLOW WATER BEARING ZONE CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Private Residence 305 N 1st Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Dining Living Bath Floorplan 1st Floor Kitchen Bath 2nd Floor Basement Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. Living = Indoor Air Sample Location
18 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Residence 305 N Main Ave.mxd WIND EFFECTSÀ Concrete Slab Foundation Heating/Cooling Furnace/Fan Proximity Monitoring Well Data: MW07 PCE Concentration: 6.11 ug/l (March 2012) 12.7 ug/l (June 2013) TCE Concentration: U ug/l (March 2012) U ug/l (June 2013) Depth to Groundwater: 8.85 ft (March 2012) ft (July 2013) POTENTIAL SOIL VAPOR Building Characteristics: Date of Construction: N/A Material of Construction: N/A Type of Foundation: Crawlspace with Concrete Floor Heating System:, Wood Stove Roof Vents: No SILTY SAND SHALLOW WATER BEARING ZONE CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Private Residence 305 N Main Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Garage Kitchen > Laundry Floorplan 1st Floor Dining 2nd Floor Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. Living = Indoor Air Sample Location > = Subslab Sample Location
19 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Residence 322 N 1st Ave.mxd WIND EFFECTSÀ Proximity Monitoring Well Data: MW11 PCE Concentration: 32.9 ug/l (March 2012) 49.8 ug/l (June 2013) TCE Concentration: 1.49 ug/l (March 2012) 3.56 ug/l (June 2013) Depth to Groundwater: 9.75 ft (March 2012) 11.4 ft (July 2013) POTENTIAL SOIL VAPOR Building Characteristics: Date of Construction: 1920 Material of Construction: Wood Type of Foundation: Crawlspace with Concrete Floor Heating System: Electric Wall/Baseboard Roof Vents: No SILTY SAND SHALLOW WATER BEARING ZONE Crawlspace Airvents (open seasonally) CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Private Residence 322 N 1st Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Bath Kitchen Basement Floorplan Living = Indoor Air Sample Location Entry Crawlspace Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information.
20 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Sales Office.mxd WIND EFFECTSÀ Crawlspace with Dirt Floor Proximity Monitoring Well Data: MW04 PCE Concentration: 63.6 ug/l (April 2012) 29.2 ug/l (June 2013) TCE Concentration: 3.83 ug/l (March 2012) U ug/l (June 2013) Depth to Groundwater: 3.18 ft (March 2012) 7.22 ft (July 2013) Roof Vents POTENTIAL SOIL VAPOR Building Characteristics: Date of Construction: N/A Material of Construction: Wood Type of Foundation: Crawlspace with Dirt Floor Heating System: /Central Air System Roof Vents: Yes Heating/Cooling Furnace/Fan Central Air Unit SILTY SAND SHALLOW WATER BEARING ZONE Crawlspace Vents (always open) CLAY Legend Silty Sand Saturated Zone Clay Conceptual Site Model Sales Office 127 N Main Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Floorplan Kitchen Conference Room Crawlspace Bath = Indoor Air Sample Location Office Office Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information.
21 Project: Produced By: J. Schane/C. Riley Approved By: M. D'Andrea Print Date: 9/17/2013 Path: X:\ \Projects\05 - Vapor Intrusion CSM\Models\Fig_CSM Sportsman Bar & Grill.mxd WIND EFFECTSÀ Crawlspace with Concrete Floor with Cracks Proximity Monitoring Well Data: MW02 PCE Concentration: 0.88 J ug/l (April 2012) 9.67 ug/l (June 2013) TCE Concentration: U ug/l (March 2012) U ug/l (June 2013) Depth to Groundwater: 1.6 ft (March 2012) 7.11 ft (July 2013) Ductless Heat Pumps Floor Drains POTENTIAL SOIL VAPOR Building Characteristics: Date of Construction: 1920's Material of Construction: Wood Type of Foundation: Crawlspace with Concrete Floor Heating System: /Central Air Roof Vents: Yes SILTY SAND SHALLOW WATER BEARING ZONE CLAY Legend Silty Sand Saturated Zone Clay Crawlspace Vents (always open) Conceptual Site Model Sportsman Bar & Grill 121 N Main Ave Vapor Intrusion Investigation Former Park Laundry Ridgefield, Washington Outdoor Patio Kitchen Floorplan Bar Seating Area Note: Building model is a representation of the actual structure and is approximate in proportion and shape. p This product is for informational purposes and may not have been prepared for, or be suitable for legal, engineering, or surveying purposes. Users of this information should review or consult the primary data and information sources to ascertain the usability of the information. C M B = Indoor Air Sample Location W B
Indoor Building Survey and Product Inventory
Indoor Building Survey and Product Inventory Preparer s Name Date/Time Prepared Preparer s Affiliation Phone No. Purpose of Investigation 1. OCCUPANT: Interviewed: Y / N Last Name: First Name: Address:
More informationCase Study of Modeled and Observed TCE Attenuation from Groundwater to Indoor Air. Christopher G. Lawless Johnson Wright, Inc.
Case Study of Modeled and Observed TCE Attenuation from Groundwater to Indoor Air Christopher G. Lawless Johnson Wright, Inc. October 18, 2004 Presentation Contents SITE BACKGROUND STUDY METHODS RESULTS
More informationChapter 2: Foundation
Chapter 2: Foundation Crawlspace [V502.1.2] [V502.1.2] [V502.1.3] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup
More informationRESIDENTIAL BUILDING REQUIREMENTS
RESIDENTIAL BUILDING REQUIREMENTS Residential Building Requirements This is an informational booklet with some of the general residential construction requirements taken from the codes adopted by Campbell
More informationA 16' x 28' Cottage with two lofts and a bedroom addition. Plans can be modified for simple or expanded layouts.
A 16' x 28' Cottage with two lofts and a bedroom addition. Plans can be modified for simple or expanded layouts. Here is a very livable small house. The main house section is 16' wide by 28' long with
More informationSustainability; in Residential, Commercial and Industrial Buildings
420 Not Heated 422 Heated ORD VI-Research Duplex and Wheeler Building, Indianapolis- Summary of Evidence to Date: Temporal Variability in Long-term Mitigation Performance and Before Mitigation: What Causes
More informationInspection Report. 1 of 8
Inspection Report Dayvolt's Home Inspections L.L.C. Date&Time of Inspection: 5/9/17, 12:10 PM Inspector's Name: Dustin Dayvolt Building Address: Sample City: State: Zip Code: Type of property inspected:
More informationHome Energy Assessment Rebate Guide
Home Energy Assessment Rebate Guide 61. Book an initial Home Energy Assessment. STEPS to Energy Savings To book an assessment, visit our website or call us at 1 877 999 6035 to be connected with an Efficiency
More informationEvergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program
Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program The following table provides a brief description of the documentation that will be required of successful LIHTC
More informationBEAVER MINES STORE 602-1ST AVENUE SOUTH BEAVER MINES
BEAVER MINES STORE 602-1ST AVENUE SOUTH BEAVER MINES FOR SALE PROPERTY INFORMATION Very busy well established country store plus residence and rental accommodations in the hamlet of Beaver Mines, located
More informationCottage of the Year SL-593 MOSER DESIGN GROUP PLAN SPECIFICATIONS ABOUT THIS PLAN PLAN PRICING. illustration MUIR STEWART
PLAN SPECIFICATIONS 4 bedrooms 3½ baths Living Area (sq ft): Main Floor: 2,028 Second Floor: 584 Total Living Area: 2,612 Exterior Wall Framing: Foundation: PLAN PRICING 2x6 Crawlspace 8 sets: $1,675 Addtional
More informationHOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS This guide is intended to provide the homeowner or contractor with the
More informationCONSTRUCTORA VARGAS NICARAGUA Building Inspection Las Delicias San Juan del Sur - Rivas Nicaragua
CONSTRUCTORA VARGAS NICARAGUA http://www.consorciovargas.com Building Inspection Las Delicias San Juan del Sur - Rivas Nicaragua Client: Teague Inspector: Jimmy Ricardo Vargas Date of the Inspection: Wednesday,
More informationOne and Two Family Additions
One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri
More informationRAPID STRUCTURAL ASSESSMENT REPORT
Structure Type: SUPERSTRUCTURE Work Order: 5540 Facility Name: Pier 68 Warehouse FIN: 1680036 Building- Bldg. # 36 Asset Number: 1680-BLDG36 Facility Code: 3490 Asset Activity: STRUCTURE TWO YR Port Engineer:
More informationIndoor Air Quality Testing at the Middle River Complex. Indoor Air Quality Testing at the Middle River Complex. For More Information
Indoor Air Quality Testing at the Middle River Complex September 2017 Indoor Air Quality Testing at the Middle River Complex Lockheed Martin has been investigating and, more recently, cleaning up soil
More informationEvaluation of Spatial and Temporal Variability in VOC Concentrations at Vapor Intrusion Investigation Sites.
Evaluation of Spatial and Temporal Variability in VOC Concentrations at Vapor Intrusion Investigation Sites. Proceeding of Air & Waste Management Association s Vapor Intrusion: Learning from the Challenges,
More informationInspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6
12:38 August 20, 2013 Page 1 of 23 Table of Contents General Information 2 Component Ratings 3 Roof Surface 4 Lots and Grounds 5 Exterior Surface and Components 7 Garage/Carport 8 Kitchen 8 Living Space
More informationPRE-FABRICATED HOUSING
Building Department 200 W. Oak Street 3 rd Floor Fort Collins, CO 80521 970-498-7700 www.larimer.org/building PRE-FABRICATED HOUSING PRE-FABRICATED HOUSING When you are buying a pre-fabricated home, you
More informationSAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD
SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD The Prescriptive Energy Code & Green Building Standard requirements for San Miguel County
More informationEdouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com
Edouard Modern Living Made Easy uichomes.com - new construction - 3 stories + full basement - 4 bedrooms - 2.5 baths - 2,380 s.f. call 314.881.2333 or e-mail sales@uicstl.com PLAN NTS DECK 13' 0" X 12'-0"
More informationNW Natural Washington Residential, Contractor Install
Want your incentive faster? Apply online. Visit www.energytrust.org/now Steps to completion: 1 Learn about energy saving potential with Energy Trust s Payback Estimator. 2 Make an energy efficiency improvement.
More informationPembridge The Country Club Collection TOWNHOMES AT CRYSTAL SPRINGS
Pembridge The Country Club Collection TOWNHOMES AT CRYSTAL SPRINGS STANDARD FEATURES LIST Foundation Concrete walls 4 concrete floor slab Interior basement unfinished Standard nine foot foundation walls
More informationOregon Guidance for Assessing and Remediating Vapor Intrusion in Buildings
Department of Environmental Quality Overview of Oregon Guidance for Assessing and Remediating Vapor Intrusion in Buildings Brownfields and Land Revitalization 2011 Conference Spokane, Washington May 13,
More informationINTERIOR ENVIRONMENT
CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,
More informationVapor Intrusion Mitigation Methods & Strategies
Vapor Intrusion Mitigation Methods & Strategies NEWMOA Workshop on Vapor Intrusion Chelmsford, MA April 12, 2006 David J. Folkes P.E. Topics Overview of Mitigation Approaches Commercial Buildings Sub-Slab
More informationInterNACHI Home Inspection Report Checklist
Client name: Inspected property address: Date and time of the inspection: Weather conditions: Approximate outdoor air temperature: People present at the time of the inspection: Estimated year built: Type
More informationFlorida Energy Extension Service
Florida Energy Extension Service Radon: The Gas, Threat, Detection, and Control 1 Gary D. Cook 2 THE GAS Radon is a potentially dangerous radioactive gas occurring naturally in the environment. It is one
More informationCHARTRES COURT Washington Avenue Houston, Texas ChartresCourtHouston.com CHARTRES COURT LLC
CHARTRES COURT 713-868 - 7226 5023 Washington Avenue Houston, Texas 77007 ChartresCourtHouston.com CHARTRES COURT LLC Features Open floor concept living/dining with spacious island kitchen Great master
More informationAnnex A STATEMENT OF WORK Radon Mitigation
Annex A STATEMENT OF WORK Radon Mitigation OBJECTIVE Royal Canadian Mounted Police (RCMP) requires reduction of the annual radon concentration levels within the noted 15 properties (found on Appendix B)
More informationA/E Design Deliverable Checklist
A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic
More information1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %
BartelsRode Gymnasium 8/11/ Building Rating System Percent Site: 1.0 Total 0 13 77% Building: 2.1 Building Exterior Elements 0 8 8% 2.2 Accessibility 0 74 74% 2.3 Structural 0 76 76% 2.4 Building Envelope
More informationH&H Job No. DS0-05. April 29, South Tryon Street Suite 100 Charlotte, NC
Risk Management Plan Gay Laundry and Cleaners DSCA ID No. 60-0044 1101 North Brevard Street Charlotte, Mecklenburg County North Carolina Dry-Cleaning Solvent Cleanup Act Program H&H Job No. DS0-05 April
More informationCrawl Spaces and Basements: Defining the Building Envelope
Crawl Spaces and Basements: Defining the Building Envelope Rich Jones: INCAA, Charlie Smith: Kentucky Housing Corporation, Albert McMahon: NYSWDA 1 By attending this session, participants will: Identify
More informationRESIDENTIAL COMPONENT TECHNOLOGY Mobile Manufactured Housing
RESIDENTIAL COMPONENT TECHNOLOGY Mobile Manufactured Housing GENERAL INFORMATION Policy Number: Insured Name: Property Address: Property Zip: Agent: Branch: Current Coverage: _ Account Number: _ PROPERTY
More information2012 IRC Sections R303 R310 Building Planning II
Study Session 3 2012 IRC Sections R303 R310 Building Planning II OBJECTIVE: To develop an understanding of the health and safety criteria of the code, including light and ventilation; minimum room areas
More informationBest management practices for vapor investigation and building mitigation decisions
www.pca.state.mn.us Best management practices for vapor investigation and building mitigation decisions Purpose This best management practices (BMPs) document describes the processes used to conduct vapor
More informationCENTRAL GREAT PLAINS SERIES
CENTRAL GREAT PLAINS SERIES 1 2 MADE FOR LIVING A heritage of excellence. Atlantic Homes has been providing families with quality homes for generations. With a unique combination of state-of-the-art manufacturing
More informationLessons from Petroleum Hydrocarbon and Chlorinated Solvent Sites Extensively Monitored for Vapor Intrusion
Lessons from Petroleum Hydrocarbon and Chlorinated Solvent Sites Extensively Monitored for Vapor Intrusion By Todd McAlary Geosyntec Consultants, Inc. EPA Workshop on Vapor Intrusion San Diego, CA March
More informationPersonal: Residential Grant Table for ecoenergy Retrofit
1 of 9 7/27/11 7:07 AM NRCan > OEE > Grant Table ecoenergy Retrofit Homes Personal: Residential Grant Table for ecoenergy Retrofit Homes Save NOW with a home retrofit grant Save later on your energy bills.
More informationCase Studies of Innovative Use of Tracers, Indicators and Field GC/MS for Assessing the Vapor Intrusion Pathway
AEHS Westcoast Conference Work Shop, March 22, 2017 San Diego, CA Case Studies of Innovative Use of Tracers, Indicators and Field GC/MS for Assessing the Vapor Intrusion Pathway Stack effect & temperature
More informationa D.R. Horton Company
Villa Mare Single-Family Homes from the high $200s* a D.R. Horton Company www.drhorton.com/sfl *Home and community information, including pricing, included features, terms, availability and amenities are
More informationChapter 6 The Improvements Section
Chapter 6 The Improvements Section In this section, identify specific data relating to the improvements on the subject property. Improvements refer to any structure permanently attached to the site. 31
More informationK and V HOMES. Client Questionnaire. Location. (Skip to page 3) Tree Removal Required. Yes No. Entrance
K and V HOMES Client Questionnaire Location Rural Lot City Lot (Skip to page 3) Tree Removal Required Yes No Entrance Existing Does it need to be modified (widened) Yes No New Entrance Needed Is a culvert
More informationRecreational Cabins. The following prices are for recreational cabins - see separate sheets for Modular Homes
Recreational Cabins Your cabin can be constructed in one of two ways: as a ' Recreational Cabin ' or as a ' Certified Modular Home '. The appearance of the two is nearly identical, as the main difference
More informationINTERIOR ENVIRONMENT
CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,
More informationRESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST
This list is provided as a guide to help you understand the information that must be contained on the construction drawings. This list is not all-inclusive of all building codes but is used as a general
More informationCell Office Website
Presented by: Maurice Torr Century 21 Westman Realty Ltd. 2915 Victoria Avenue Brandon, Manitoba Cell 204.729.6644 Office 204.725.0555 Email mctorr@inethome.ca Website http://www.century21.ca/maurice.torr
More informationNew Homes Forestbrook Road. Yes, it s INCLUDED!
Sugar Mill is a Covenant Restricted Community. New Homes Forestbrook Road Yes, it s INCLUDED! Granite Countertops Ceramic Tile Kitchen Floors Front Brick Accents Upgraded Kitchen Cabinets Ceramic Tile
More informationBRUCE MONROE AT PARK VIEW ELEMENTARY SCHOOL MODERNIZATION PROPOSED MAIN ENTRY - EXTERIOR RENDERING
PROPOSED MAIN ENTRY - EXTERIOR RENDERING EXISTING SITE AERIAL PHOTOGRAPH 6TH STREET NW PEDESTRIAN ACCESS School access to existing alley leads students through vehicular path CHAIN LINK ENCLOSED PARKING
More informationRESIDENTIAL MOLD ASSESSMENT. Final Report. Your Address Here
2847 Barnard Street San Diego California 92110 Phone 619.501.0185 Mobile 619.203.9774 Fax 619.501.9843 hoveyenv@cox.net RESIDENTIAL MOLD ASSESSMENT Final Report Your Address Here September 1, 2003 Prepared
More informationIn Situ Thermal Remediation and Principles of Electrical Resistance Heating (ERH)
In Situ Thermal Remediation and Principles of Electrical Resistance Heating (ERH) Reusing Contaminated Land Conference Session 1C Cleanup Approaches that Work Seattle WA, October 2, 2014 David Fleming
More informationDavis Frame Co., Inc. Construction Budget Considerations
Davis Frame Co., Inc. Construction Budget Considerations ITEM BID 1 BID 2 BID 3 MISCELLANEOUS COSTS Surveying Building Permit Engineering Fees Interest on Construction Loan Property Taxes Hazard & Liability
More informationExhibit A Declaration of Restrictions Development and Design Standards For Ridge Park Estates
Exhibit A Declaration of Restrictions Development and Design Standards For Ridge Park Estates Spokane County, Washington For All Property Owners The following Development and Design Standards shall be
More informationSITE PLAN CRITERIA FOR MUNICIPAL SOLID WASTE & RECYCLABLES STORAGE & ENCLOSURE REQUIREMENTS
SITE PLAN CRITERIA FOR MUNICIPAL SOLID WASTE & RECYCLABLES STORAGE & ENCLOSURE REQUIREMENTS April 2009 General Solid Waste and Recycling Service Responsibilities: The City of Denton is the exclusive provider
More informationFeatures & Amenities. EXTERIOR FINISHES COMMUNITY FEATURES
Features & Amenities COMMUNITY FEATURES EXTERIOR FINISHES WARRANTY COVERAGE Located in the heart of Troy along the east side of Rochester Road, between Wattles and Long Lake Roads Easy access to I-75 and
More informationMount Vernon Elementary School Grades PK 5
Barbour County Schools Comprehensive Educational Facilities Plan 2010-2020 Mount Vernon Elementary School Grades PK 5 Blackwood Associates, Inc. / MSES consultants, Inc. / Roy Blizzard and Associates Mount
More informationHOMES FOR SALE. Under Construction. Quality Stick Built Starting at $278,000. Watford City North Dakota WATFORDCITYREALESTATE.
HOMES FOR SALE Watford City North Dakota Under Construction Quality Stick Built Starting at $278,000 CHEYENNE 3 Car Garage: rendering for visual purposes only, actual Home may vary slightly. Starting at
More informationAUGUSTA Series - Starting at $70, sq ft
PREDESIGNED COLLECTION Everything our homeowners have grown to love in our custom homes in a predesigned, standard package. Ready to go straight to production, eliminating design fees and reducing lead
More informationA/E Design Deliverable Checklist
A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic
More information2003 International Residential Building Code
2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less
More informationProposed Changes to EPA s Spreadsheet Version of Johnson & Ettinger Model (and some new spreadsheet tools)
Proposed Changes to EPA s Spreadsheet Version of Johnson & Ettinger Model (and some new spreadsheet tools) Workshop Integrating Observed & Modeled Vapor Attenuation The 15th Annual AEHS West Coast Conference,
More informationTable of Contents. Page Title
Page Title Table of Contents 1 Floor plan/ Room utilization 2 Elevation (EAST) 3 Elevation (SOUTH) 4 Elevation (WEST) 5 Elevation (NORTH) 6 Foundation plan details 7 Foundation cross sections A Main grade
More informationE d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e
I N D E X E d u c a t i o n a l S e m i n a r s f o r B u i l d i n g & R e s i d e n t i a l C o d e Title Course Number *Seminar Length (days) Pg. Class Scheduling Policies 8 International Building Code
More informationEarth Advantage New Homes Standard - Points Worksheet 2012 Site Built Residential Oregon. Energy Health Land Materials Water
Earth Advantage New Homes Standard - Points Worksheet 22 Site Built Residential Oregon The Earth Advantage program consists of individual measures that have been evaluated by using the five categories
More informationUpdated J&E Model VIAModel.xls
Updated J&E Model VIAModel.xls Helen Dawson, Ph.D. USEPA Region 8 AEHS Spring 2006 What s Different? Combines screening and advanced versions of the groundwater and soil gas spreadsheets. Provides default
More informationFoundation/Site Work Code Requirements
Q: What is a Foundation Only permit and why did I receive one when I filed for a full Building Permit? All Building Permits for new construction and additions are reviewed for zoning compliance. This review
More informationU.S. EPA s Vapor Intrusion Database: Preliminary Evaluation of Attenuation Factors
March 4, 2008 U.S. EPA s Vapor Intrusion Database: Preliminary Evaluation of Attenuation Factors Office of Solid Waste U.S. Environmental Protection Agency Washington, DC 20460 [This page intentionally
More informationBoulder City NV Prepared by (Print Name) Signature Date
City of Boulder City Community Development Department Building & Safety Division 401 California Avenue Boulder City, NV 89005-2600 702-293-9282 (Main Line) 702-293-9392 (Fax) 2009 International Energy
More informationEach proposed project will be reviewed for compliance with the following codes as applicable.
VILLAGE OF PALATINE DEPARTMENT OF BUILDING AND INSPECTION SERVICES 200 EAST WOOD STREET PALATINE, IL 60067-5339 Telephone (847)359-9042 Obtaining a Residential Building Permit: Submittal Requirements The
More informationRadon Vent Pipe System. Labeling Performance Indicators
Section 6 Radon Vent Pipe Labeling Performance Indicators Radon Vent Pipe System Connected after sub-grade system installed Pipe cannot be trapped Provide space in chases Support at each floor level Discharge
More informationPROPOSED PLAN DEVELOPMENT 2501 WEST HOMER STREET. Guardian Properties, LLC. September 9, 2015
PROPOSED PLAN DEVELOPMENT 2501 WEST HOMER STREET Guardian Properties, LLC September 9, 2015 2501 W Homer Zoning Map Scale: 1:080 Project Site 2501 W Homer Aerial Scale: 1:048 Project Site 2501 W Homer
More informationDate Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection
Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over
More informationYou ll be amazed by our beautiful timber frame construction with exposed post and beams using Eastern White Pine from floor to ceiling.
772 Cedar Grove Rd Shepherdsville, KY 40165 502-921-0002 or 800-289-0988 amishmadecabins.com Torch Award Winner Very Small Business, 2015 BBB serving Louisville, Southern Indiana and Western Kentucky Amish
More information1 BASE HOME CONSTRUCTION SPECIFICATIONS: TOWNHOMES 5-13-2015 Note: Specifications noted below may change based on selected options. Verify upgrades from the base specifications with the option sheets and
More informationEncapsulated, Sealed & Closed Crawlspace Installation Manual
YourCrawlSpace, Inc. 1007 Johnni4 Dodds Blvd. Mt. Pleasant, SC 29464 Toll Free: 877-44-CRAWL (27295) Local: (843) 593-1115 Encapsulated, Sealed & Closed Crawlspace Installation Manual Copyright 2017 Your
More informationCITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction
CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction In order to facilitate sustainable construction practices, all new projects* must comply with the State
More informationDoors, Windows, Stairs & Fireplaces Doors Doors Outdoor Entry Outdoor Entry Doors Doors Outdoor Entry Outdoor Entry
Doors, Windows, Stairs & Fireplaces Doors Outdoor Entry 36 minimum entry Main/guest entrance open to social area Easy use lever handles Doors Outdoor Entry Weather resistant surface Solid wood or foam
More informationBASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)
BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from
More informationThe Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage
The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco
More information3D Home Improvement and Inspection Services, Inc
Property Inspection Report Cover Page ABC Disney Lane, Winter Garden FL, 34787 Inspection prepared for: John Doe Inspection Date: 7/15/2010 Time: 11:00 am Age: 6 Years Size: 3,378 LSF / 4,427 TSF Weather:
More informationThermal Remediation Services, Inc.
Thermal Remediation Services, Inc. Electrical Resistance Heating for Rapid Remediation of DNAPL April 2003 David Fleming 425-396-4266 dfleming@thermalrs.com www.thermalrs.com What is Electrical Resistance
More informationDistribution Restriction Statement
DEPARTMENT OF THE ARMY U.S. Army Corps of Engineers CEMP-ET Washington, DC 20314-1000 ETL 1110-3-438 Technical Letter No. 1110-3-438 15 September 1993 Engineering and Design INDOOR RADON PREVENTION AND
More informationProperty Condition Assessment
Property Condition Assessment Pewaukee, WI 53072 Inspection Date: 1/6/15 Prepared For: Report Number: Prepared By: Shamrock Building Inspection Consultants LLC N29 W29951 Shel-Mar Dr. Pewaukee, WI 53072
More informationTHE DEVELOPMENT REVIEW BOARD. 1. New construction or relocation of single-family homes, including mobile/modular and manufactured homes.
- I THE DEVELOPMENT REVIEW BOARD The General Plan of the City of Lakewood has been established to guide and promote the orderly growth and development of the community. The goals of the City, specified
More informationHighland Park. Exceptional Interiors (cont.) Green Technology. Designer Kitchen Features. Distinctive Exterior Features
unit 2 HOMES 650 Mill Valley Parkway 2332 Sq.Ft. 3-Car 4/3 $542,800 6 Mt. Shasta Views 643 Mill Valley Parkway 2332 Sq.Ft. 3-Car 4/3 $552,800 8 Mt. Shasta Views Under construction 945 Rollingview Raised
More informationAPPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.
Chapter 1 101.1 Title. These regulations shall be known as the North Carolina Energy Conservation Code as approved by the North Carolina Building Code Council on March 11, 2008, to be effective January
More informationRESIDENTIAL CONSTRUCTION New Dwellings and Additions
How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:
More informationDesigning with Energy-Efficient Lighting
Designing with Energy-Efficient Lighting Why Care? Why Care? Reducing energy use helps decelerate climate change by preventing greenhouse gas emissions As energy prices continue to rise, the importance
More informationUse of Crawl Space Sampling Data and Other Lines of Evidence for Evaluating Vapor Intrusion
CALIFORNIA ENVIRONMENTAL PROTECTION AGENCY DEPARTMENT OF TOXIC SUBSTANCES CONTROL Use of Crawl Space Sampling Data and Other Lines of Evidence for Evaluating Vapor Intrusion C.Y. Jeng and William Bosan
More informationInspection Report Summary
Inspection Report Summary Prepared for: Property Location: XXXXXXXXXXXXXXXX XXXXXXXXXXXXX Dallas, Texas 75XXX Contact Info: Home Phone: XXXXXXXXXXXX E-mail: XXXXXXXXXXXXXXXX Date of Inspection: October
More informationProject Findings: Appendix 2
NSF Final Report CMMI-1034874 Project Findings: Appendix 2 Selected Damage Photos of Engineered Buildings PART 2. Teleco Office Tower Civil Engineering and Engineering Mechanics Department University of
More informationCOOLIDGE SENIOR HIGH SCHOOL
INITIAL YEAR BUILT 1940 BUILDING AREA 271,300 SF CURRENT PROGRAM CAPACITY 1240 ENROLLMENT 2008 652 WARD 4 PROPOSED PROGRAM CAPACITY 1100 Site Plan COOLIDGE - 1 PROPOSED PROGRAM PROFILE GRADE CONFIGURATION
More informationBuilding over or close to a public sewer
Building over or close to a public sewer Place holder image thameswater.co.uk/developerservices Building over or close to a public sewer Did you know Thames Water is legally responsible for more than 100,000
More informationApplying for Permits to build a new house in Linn County
Planning & Development Linn County, Iowa Building Division Linn County Building Code Residential Guidelines Single Family Dwellings Page 1 of 4 Applying for Permits to build a new house in Linn County
More informationAugust Vapor Intrusion Guidance FAQs
August 2017 2017 Vapor Intrusion Guidance FAQs Topics: A. General B. Effect of New Guidance on In-Process Sites C. Future Use of Site D. Modeling E. Off-Site Properties F. Preferential Pathways G. Proximity
More informationPIKES PEAK REGIONAL BUILDING DEPARTMENT
PIKES PEAK REGIONAL BUILDING DEPARTMENT Manufactured Residential Buildings - WOODLAND PARK (CITY LIMITS) Pikes Peak Regional Building Department issues permits and performs inspections of manufactured
More informationFrost Protected Shallow Foundations in PA
PHRC Webinar Series Tuesday, February 14 @ 1pm Frost Protected Shallow Foundations in PA Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University Park,
More informationIs this the maturation Phase of Vapor Intrusion Investigations?
Is this the maturation Phase of Vapor Intrusion Investigations? Presenter: Will Elcoate June 27 th, 2012 EPA Moves forward with Vapor Intrusion EPA plans to tear down three city businesses Columbus Telegram
More informationThermal Remediation Services, Inc.
Thermal Remediation Services, Inc. Electrical Resistance Heating for In-Situ Remediation of Soil & Groundwater December 10, 2002 Greg Beyke (770) 794-1168 gbeyke@thermalrs.com www.thermalrs.com 1 1 2 2
More information