Luxwood Building System

Size: px
Start display at page:

Download "Luxwood Building System"

Transcription

1 Certificate number: CM40214 THIS TO CERTIFY THAT Certification Body: ABN: JAS-ANZ Accreditation No. Z AK PO Box 7144, Sippy Downs Qld (07) Certificate Holder: PHE Solutions Pty Ltd ABN: Collins Street, Benowa QLD 4217 Ph: Type and/or use of product: The Luxwood Building System is an Engineered structural building system, assembled on site consisting of walls, floors and ceilings, upto 3 storey high, type C construction. Performance Requirement(s) Luxwood Building System Description of product: The Luxwood Building System is an Engineered prefabricated building system consisting of Luxwood panels and POLEX board. Refer A2 for more information. COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S) BCA 2016 Volume One BP1.1 (a) FP1.4 FP5.2 (a) Structural reliability (c) Weatherproofing Walls (d) Deemed-to-Satisfy Provision(s): J1.5 Building Fabric walls (f) Volume Two P2.1.1 (a) P2.2.2 P2.4.6 (a) (a) (a) Structural stability and resistance to actions (c) Weatherproofing Sound insulation (d) Building fabric thermal insulation (f) Building fabric - External walls (f) State or territory variation(s): NT Part F5 NT P2.4.6 SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B Limitations and conditions: a. The Luxwood Building System must be installed in accordance with the Luxwood Panel Building System Methods & Guideline Installation Manual Rev1. b. Flooring Loads must be designed by a suitably licensed Engineer in accordance with AS/NZS :2002 Reference Values of Imposed Floor Actions. c. The Luxwood Building System is not permitted for use in Cyclonic regions unless designed and approved by a suitably licensed Engineer in accordance with AS Building classification/s: Class 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10 Date of issue: 20/06/2017 John Thorpe - CMI Don Grehan Unrestricted Building Certifier Date of expiry: 20/06/2020 Certificate number: CM40214 This certificate is only valid when reproduced in its entirety. Page 1 of 5

2 d. The Luxwood Building System achieves a minimum Acoustic Performance of Rw/Rw+Ctr 47/44db for walls and floors. Where required, the system may be deigned to achieve Rw/Rw+Ctr 55/52db or higher. For further details, see the Luxwood Building System Methods Guideline and Installation Manual Rev1. e. Fire Resistance provisions do not form part of this certification. If a Fire Resistance is required, contact the Certificate Holder. f. Thermal Resistance provisions J1.5, (a) and (a) only applies for climate zones 1 to 7. g. This certification relates only to the product as described above, and must be read, considered and used as a whole document it may be considered misleading and will be incomplete to be selective. Scope of certification: The CodeMark Scheme is a building product certification scheme. The rules of the Scheme are available at the ABCB website This Certificate of Conformity is to confirm that the relevant requirements of the Building Code of Australia (BCA) as claimed against have been met. The responsibility for the product performance and its fitness for the intended use remain with the certificate holder. The certification is not transferrable to a manufacturer not listed on Appendix A of this certificate. Disclaimer: The Scheme Owner, Scheme Administrator and Scheme Accreditation Body do not make any representations, warranties or guarantees, and accept no legal liability whatsoever arising from or connected to, the accuracy, reliability, currency or completeness of any material contained within this certificate; and the Scheme Owner, Scheme Administrator and Scheme Accreditation Body disclaim to the extent permitted by law, all liability (including negligence) for claims of losses, expenses, damages and costs arising as a result of the use of the product(s) referred to in this certificate. Certificate number: CM40214 This certificate is only valid when reproduced in its entirety. Page 2 of 5

3 APPENDIX A PRODUCT TECHNICAL DATA A1 Type and intended use of product As per page 1. A2 Description of product A full system may include: Wall / Floor Panel; Wall Corners; U Channel; Roof Trusses and Frames; Fastening; POLEX Boards; Window and Door Frames; External Cladding; Ceiling System. Please refer to the Luxwood Panel Building System Methods & Guideline Installation Manual Rev1 for further details. Luxwood Panels Standard Thickness: 100mm Width: 450mm Length: 300mm up to 3000mm. POLEX Boards P1 - Compressed 1220mm x 2440mm x 9mm weatherproof sheets (grey). Used as a wall or floor substrate. P2 - Compressed 1220mm x 2440mm x 9mm weatherproof sheets (white). Used as an internal and external wall or soffit substrate when rendered and painted upto approx. 10mm thick. P3 - Aerated paper faced 1200mm x 2400mm x 10mm sheets (green). Used as a substitute for plasterboard for walls and ceilings. Wall / Floor Panel Wall Corners U Channel Roof Trusses and Frames Certificate number: CM40214 This certificate is only valid when reproduced in its entirety. Page 3 of 5

4 Fastening POLEX Boards Window and Door Frames External Cladding Ceiling System A3 Product specification Structural ability and resistance to action: Description Compressive strength Hanging force Results 6.3 MPa 1000N Certificate number: CM40214 This certificate is only valid when reproduced in its entirety. Page 4 of 5

5 Flexure strength rate 0.98 A4 Manufacturer and manufacturing plant(s) Beijing Hengtong Innovation Luxwood Technology Co. Ltd No.86-5, Wanxing Rd, Changyang, Fangshan District, Beijing, China, A5 Installation requirements 1. The Luxwood Building System must be designed by a suitably qualified Engineer and installed by a competent person/s as deemed by PHE Solutions Pty Ltd. A6 Other relevant technical data Nil APPENDIX B EVALUATION STATEMENTS B1 Evaluation methods 1. Structural Provision A2.2 (a)(iii) & (b) and (a)(iii) & (b). A certificate from a professional engineer. 2. Damp and Weatherproofing A2.2 (a)(iii) & (b) and (a)(iii) and (b). A certificate from a professional engineer. 3. Thermal Provision A2.2 (a)(iii) & (b) and (a)(iii) & (b). A certificate from a professional engineer. 4. Acoustic Provision A2.2 (a)(iii) and (a)(iii). A certificate from a professional engineer. B2 Reports 1. Graeme Moulston & Associates Engineering Performance Certification Report No. 1041_001, Structural provisions in accordance with AS/NZS : Graeme Moulston & Associates Engineering Performance Certification Report No MW & , Acoustic performance. 3. Ben Van Zly PhD MSc (Eng) Report No. G1321, Luxwood Subfloor & Wall System Assessment of Acoustic Performance. 4. Graeme Moulston & Associates Engineering Report No. 1045_001, Performance Certification for Thermal Performance. 5. Graeme Moulston & Associates Engineering Report No. 1046_001, Performance for Water Penetration. 6. Petrovic Engineering Letter of Appraisal No dated Product meets requirements for: Structural provision and Energy efficiency. Certificate number: CM40214 This certificate is only valid when reproduced in its entirety. Page 5 of 5

Certificate number: CM40087 Rev3

Certificate number: CM40087 Rev3 Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: ABN: 22 750 783 065 19 Lowermill Rd,

More information

ADVISORY NOTE Fire Performance of External Walls and Cladding Application

ADVISORY NOTE Fire Performance of External Walls and Cladding Application ADVISORY NOTE 2016-3 Fire Performance of External Walls and Cladding Application NCC Volume: Section/Part: One Various Date first issued: August 2016 Date revised: September 2016 Copyright and licence

More information

Evaluation Report. for. Empire West, Inc Graton Road Post Office Box 511 Graton, California 95444

Evaluation Report. for. Empire West, Inc Graton Road Post Office Box 511 Graton, California 95444 for Empire West, Inc. 9270 Graton Road Post Office Box 511 Graton, California 95444 CertMark International Pty Ltd (CMI) has awarded this Certification to the company named above for the Product/system

More information

SEPARATING WALLS CLASS 1A

SEPARATING WALLS CLASS 1A TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND SEPARATING WALLS CLASS 1A (DUPLEXES, TOWNHOUSES, BUILDINGS ROW HOUSES, TERRACE HOUSES) 33 RECOMMENDED PRACTICE // AUGUST 2014 Fire and sound are important

More information

Building regulations now in force

Building regulations now in force BCA Section J: Guide to compliance Publication date July 2008 Building regulations now in force BCA SECTION J: Mandatory energy efficiency measures for non-residential construction The new BCA Section

More information

A GUIDE TO WINDOW AND DOOR SELECTION

A GUIDE TO WINDOW AND DOOR SELECTION Australian window association guide series A GUIDE TO WINDOW AND DOOR SELECTION An industry guide to the selection and certification of windows and doors Background Foreword As part of its commitment to

More information

CertMark Australasia CodeMark Assessment Brief' THE OZONE PANEL BUILDING SYSTEM. For

CertMark Australasia CodeMark Assessment Brief' THE OZONE PANEL BUILDING SYSTEM. For CertMark Australasia CodeMark Assessment Brief' For THE OZONE PANEL BUILDING SYSTEM PURPOSE Ozone Panels are load bearing precast panels made up of two facades of OSB3 composite sourced from organically

More information

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 2: DuraGalPlus RHS as lintels (garage beams, window heads)

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 2: DuraGalPlus RHS as lintels (garage beams, window heads) N1 to N3 Domestic Construction Manual Volume 2: RHS as lintels (garage beams, window heads) Domestic Construction Manual Volume 1: Roof beams - N1 to C3 (N1 to C3 - Rafters) (N1 to N3 - Roof beams, strutting

More information

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers)

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 3: DuraGalPlus RHS as floor beams (bearers) N1 to N3 Domestic Construction Manual Volume 3: RHS as floor beams (bearers) DuraGal Domestic Construction Manual Volume 1: Roof beams - N1 to C3 (N1 to C3 - Rafters) (N1 to N3 - Roof beams, strutting

More information

SOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014

SOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014 SOLITEX EXTASANA WALL PROTECTION MEMBRANE Amended 06 May 2014 BRANZ Appraisals Technical Assessments of products for building and construction. Pro Clima Australia Pty Ltd PO Box 924 Gosford NSW 2250 Australia

More information

BCA Section J Compliance Report. Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown

BCA Section J Compliance Report. Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown BCA Section J Compliance Report Alterations & Additions to Cottage at St Johns College 10 Missenden Road Camperdown Prepared by: Gradwell Consulting ABN 68 872 791 784 Sustainability Consultants PO Box

More information

MaxiWall Low-Rise Multi Residential External Wall System

MaxiWall Low-Rise Multi Residential External Wall System MaxiWall Low-Rise Multi Residential External Wall System Technical Guide Our Story With over 110 years in the timber industry, Big River is now one of Australia s largest timber manufacturing and marketing

More information

e x a n g l e installation guide exangle Finishing Sections

e x a n g l e installation guide exangle Finishing Sections e x a n g l e installation guide exangle Finishing Sections rondo exangle Finishing Sections CORNER BEADS 90º external corner beads are available in two profiles. Use P01 for a sharper finish or P32 for

More information

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS INTRODUCTION BENCHMARK Wall Liner is an engineered insulated panel system that is ideal for fully supporting single skin metal sheeting such as zinc,

More information

Finish coat painted with a 100% acrylic. Multi purpose scratch coat

Finish coat painted with a 100% acrylic. Multi purpose scratch coat Finish coat painted with a 100% acrylic Multi purpose scratch coat 200mm self-adhesi ve mesh coated with insulclad base 40mm P VC washers and class 3 screws spaced at 300mm INSULCLAD DIRECT FIXED CLADDING

More information

Galintel Steel Lintels

Galintel Steel Lintels Galintel Steel Lintels selection guide & load tables Galintel pty ltd Galintel Pty Ltd A division of the Graham Group An Australian owned Company with more than 50 years experience The Graham Group is

More information

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION Insulation A4/6 TB055W AW2244 Issue 6 Oct 2017 WHITE-FACED THERMO REFLECTIVE INSULATION Innovative cross-linked closed cell insulation core 3-in-1 Insulation, vapour barrier and radiant barrier Helps achieve

More information

Building Regulations

Building Regulations Product 1.1 Technobond is a range of polyester fibre insulation used as thermal and acoustic insulating material in ceilings, roofs and walls of buildings. Appraisal No.69 [010] BRANZ Appraisals Technical

More information

GTEK TM SOUND GTEK TM IMPACT

GTEK TM SOUND GTEK TM IMPACT APRIL 2016 TECHNICAL BROCHURE GTEK TM SOUND GTEK TM IMPACT gtekplasterboard.com.au GTEK TM SOUND WHY GTEK TM? WITH OUR ALL-AUSTRALIAN GTEK RANGE OF INTERIOR LINING PRODUCTS, YOU BENEFIT FROM SUSTAINABLE,

More information

Brick Veneer Walls. Insulation

Brick Veneer Walls. Insulation Insulation A4/8 BV AW2157 Issue 7 Nov 2016 Brick Veneer Walls Insulation guide Helps achieve a 6-star house energy rating Rigid Kingspan Kooltherm and flexible Kingspan AIR-CELL solutions available Fibre-free,

More information

exangle installation guide EXANGLE Finishing Sections

exangle installation guide EXANGLE Finishing Sections exangle installation guide EXANGLE Finishing Sections rondo exangle FINISHING SECTIONS GENERAL INFORMATION The Rondo EXANGLE and EXANGLE Render & Texture range has been developed over 45 years by Rondo

More information

Great Ocean Rd Ice Creamery

Great Ocean Rd Ice Creamery Great Ocean Rd Ice Creamery BCA Section J - JV3 Compliance Report Revision: 01 Job No: 2171 Date: 7 July 2015 ADP Consulting Pty Ltd Level 10, 10 Queens Rd, Melbourne Vic 3004 www.adpconsulting.com.au

More information

Insulbreak. Insulation. thermal break solution

Insulbreak. Insulation. thermal break solution Insulation A4/8 TB AW2199 Issue 8 May 2017 Insulbreak thermal break solution 3-in-1 Insulation, thermal break and vapour barrier Delivers a R0.20 thermal break solution for steel-framed construction Helps

More information

Roof Systems. Span Tables & Thermal Ratings. Custom Roof Panel

Roof Systems. Span Tables & Thermal Ratings. Custom Roof Panel Roof Systems Custom Roof Panel Tables & Thermal Ratings Version 2015.02 A fully customised and complete roofing solution that is quick to install with superior span and cantilever capabilities. UP TO CMA-CM40091

More information

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals Appraisal No. 959 [2017] HYDRATHANE INTERIOR WATERPROOFING MEMBRANE BRANZ Appraisals Technical Assessments of products for building and construction. Construction Chemicals Pty Ltd 49-57 Davis Street Wingfield

More information

Timber-framed Construction for Commercial Buildings Class 5, 6, 9a & 9b

Timber-framed Construction for Commercial Buildings Class 5, 6, 9a & 9b 03 Seaford Life Saving Club, Robert Simeoni Pty Ltd Architects Timber-framed Construction for Commercial Buildings Class 5, 6, 9a & 9b Design and construction guide for BCA compliant sound and fire-rated

More information

City of High Point Airport Overlay District Noise Level Reduction Design Standards

City of High Point Airport Overlay District Noise Level Reduction Design Standards City of High Point Airport Overlay District Noise Level Reduction Design Standards Part A. Residential Design Standards for Zone 3 I. NOISE LEVEL REDUCTION (NLR) REQUIREMENT FOR ZONE 3. The City of High

More information

exangle installation guide EXANGLE Finishing Sections

exangle installation guide EXANGLE Finishing Sections exangle installation guide EXANGLE Finishing Sections rondo exangle FINISHING SECTIONS GENERAL INFORMATION The Rondo EXANGLE and EXANGLE Render & Texture range has been developed over 45 years by Rondo

More information

Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12

Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12 Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12 February 2012 Legal Notice - Disclaimer and exclusion of liability This document is provided

More information

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE

Insuliner. Insulation REFLECTIVE INSULATION FOR USE WHERE Insulation A4/8 TB055G2 AW2235 Issue 8 Sep 2017 Insuliner REFLECTIVE INSULATION FOR USE WHERE it acts as the WALL OR CEILING LINING Group 2 NCC fire classification Designed for warehouses and commercial

More information

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION Insulation A4/6 TB055F AW2002 Issue 4 Sept 2015 THERMO REFLECTIVE INSULATION Innovative cross-linked closed-cell insulation core Improved Class 0 fire performance to stringent international standards 3-in-1

More information

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings Boris Iskra Forest & Wood Products Australia This Presentation 1. Fire Hazard Properties Building Code of Australia Volume

More information

1 Product. 2 Scope of Use. IGNIS PERFORMANCE SOLUTION No I01R01. Ritek XL Thermal Wall System

1 Product. 2 Scope of Use. IGNIS PERFORMANCE SOLUTION No I01R01. Ritek XL Thermal Wall System IGNIS PERFORMANCE SOLUTION Evaluation No.4214 [2016] 1 Product Ignis Solutions has been engaged by Ritek Building Solutions to evaluate compliance of their Ritek XL Thermal Wall System against the Building

More information

EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE

EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE FLOORING SYSTEM 50mm, 62mm and 75mm EDITION: MAY 2016 DESIGN AND INSTALLATION GUIDE CMA-CM40172 HEAD OFFICE Nasahi Building Materials Australia Pty Ltd 1331 Stud Rd, Rowville, Victoria, 3181 P: 1300 2

More information

Quick guide to product substitution

Quick guide to product substitution Quick guide to product substitution p1 of 12 Contents Use of this guide... 2 Purpose... 3 Introduction... 3 Step 1: Consider the law... 5 Step 2: Consider the building implications... 7 Step 3: Implement

More information

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS Controlled Environments Controlled Environment Panel System KS1100 CS Overview Kingspan controlled environment panel systems are designed for use within temperature controlled and hygiene safe environments

More information

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185 GENERAL REQUIREMENTS 185 FRAMING 185 PLASTERBOARD LAYOUT 189 PLASTERBOARD FIXING 190 EXTERIOR

More information

CHAPTER 3: Modern Methods of Construction (MMC)

CHAPTER 3: Modern Methods of Construction (MMC) CONTENTS 3.1.1 INTRODUCTION 3.1.2 SUITABILITY OF SYSTEMS AND COMPONENTS 3.1.3 TYPES OF MODERN METHODS OF CONSTRUCTION (MMC) 3.1.4 SUITABILITY OF SYSTEMS TO MEET WARRANTY REQUIREMENTS 3.1.5 INSULATED CONCRETE

More information

19 New-type Antiseismic and Energy-Saving Building

19 New-type Antiseismic and Energy-Saving Building 19 New-type Antiseismic and Energy-Saving Building Q.Li, Q.Cui, Y.Cui, D.Wong China Building Academy, China Abstract: This paper introduces a new-type of anti-seismic and energy-saving building system

More information

Position Statement. Product compliance and evidence of suitability

Position Statement. Product compliance and evidence of suitability Version 1 Approved for release July 2014 1.0 FPA Australia advocates the following in relation to product compliance and for fire protection products used in Australia: Fit for purpose 1. Fire protection

More information

FIRMLOK FLOORING SYSTEM DESIGN AND INSTALLATION MANUAL

FIRMLOK FLOORING SYSTEM DESIGN AND INSTALLATION MANUAL FLOORING SYSTEM DESIGN AND INSTALLATION MANUAL NON-CYCLONIC AREAS LYSAGHT Introduction LYSAGHT STRUCTURAL BEAMS structural beams consist of two interlocking c-sections. They are light, strong and universal

More information

Walling System. Very Quick. Very Easy

Walling System. Very Quick. Very Easy Walling System Very Quick. Very Easy Walling System The Versaloc Walling System is a new Dry Stack walling system from Adbri Masonry which creates significant productivity gains, by allowing units to be

More information

When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily

When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily When demanding consistent quality, specify FILL to assist in achieving highly improved sound performance in multifamily construction. FILL is an integral component of a well designed floor/ ceiling assembly.

More information

Report for CSR Hebel. Impact of various wall and floor construction options on 5 star compliance for two houses. by Tony Isaacs Consulting Pty Ltd

Report for CSR Hebel. Impact of various wall and floor construction options on 5 star compliance for two houses. by Tony Isaacs Consulting Pty Ltd Tony Isaacs Consulting Pty Ltd Sustainable Buildings Specialist Report for CSR Hebel Impact of various wall and floor construction options on 5 star compliance for two houses by Tony Isaacs Consulting

More information

Symonite Decorative Panelling

Symonite Decorative Panelling Symonite Decorative Panelling WHY SYMONITE? Symonite is the only Australian manufactured aluminium composite panel. An Australian owned company whose continuous composite panel research and development

More information

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet Insulated Roof & Wall Panels Foilback KS1000 FB Insulated Roof Panels Overview Kingspan Foilback is supplied with a pre-painted Steel external (Aluzinc also available on request) with a choice of silver

More information

K5 External Wall Board

K5 External Wall Board Insulation A4/6 K5 AW2194 Issue 9 Apr 2017 INSULATION FOR USE BEHIND TRADITIONAL AND LIGHTWEIGHT POLYMER MODIFIED RENDERS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell

More information

AS/NZS 2589:2007 AS/NZS

AS/NZS 2589:2007 AS/NZS AS/NZS 2589:2017 Australian/New Zealand Standard Gypsum linings Application and finishing Superseding AS/NZS 2589:2007 AS/NZS 2589:2017 AS/NZS 2589:2017 This joint Australian/New Zealand standard was prepared

More information

Flagstone Development - Noise Assessment for Stage 1K and 1U

Flagstone Development - Noise Assessment for Stage 1K and 1U 25 September 2017 620.10512.00900 Flagstone Stage 1K & 1U.docx Peet Flagstone City Pty Ltd Level 2, 167 Eagle Street Brisbane QLD 4000 Attention: Stephanie Clark Dear Stephanie (SLR) has been commissioned

More information

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit: TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION 355-7575 Ext. 395 Needed to Obtain Permit: 1. Building Permit Application, and/or residential plumbing permit application, as applicable, to be

More information

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation. SECTION B Steel Frame Wall Systems. Contents. SUBJECT Steel Stud Selection Tables Introduction Design Considerations Installation Components PAGE B2 B4 B4 B6 B7 System Specifications Single Stud Staggered

More information

SECTION NON-STRUCTURAL METAL FRAMING

SECTION NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable

More information

FULLY INTEGRATED ROOF SYSTEM

FULLY INTEGRATED ROOF SYSTEM ROOFSYSTEMS I was so amazed that after my walls were erected, the Ritek Custom Roof Panel went up and was completed in two days. Within the first week of construction, the trades could work, sheltered

More information

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. SECTION D Wall Systems. Contents. SUBJECT Introduction Design Considerations Installation Components PAGE D2 D2 D4 D5 System Specifications Stud One Side Stud Both Sides Stud and Furring Channel Resilient

More information

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design BRADY INNOVATIONS, LLC. PROX HEADER SYSTEM CSI Section: 05 05 23 Metal Fastenings 05 40 00 Cold-formed Metal Framing 1.0 RECOGNITION Brady Innovations, LLC s ProX Header System recognized in this report

More information

Building Design Data

Building Design Data Building Design Data.. 1. Building Design The KORE ICF System is designed to meet the requirements of the Building Regulations 1997-2006, in the case of two storeys, single occupancy dwellings. If the

More information

Detached Garage Construction Information

Detached Garage Construction Information Detached Garage Construction Information In order to issue a building permit for construction of a detached garage, the applicant must submit: Completed development and building permit applications Method

More information

The Insulbrick Building System www.insulbrick.com.au 2 Insulbrick Insulated Concrete Formwork for Australian Standards Insulbricks provide a fire retardant expanded polystyrene [EPS] formwork for casting

More information

TEST REPORT. Bushfire resistance test of an external wall system to BAL A40 in accordance with AS EWFA Report No:

TEST REPORT. Bushfire resistance test of an external wall system to BAL A40 in accordance with AS EWFA Report No: TEST REPORT Bushfire resistance test of an external wall system to BAL A40 in accordance with AS1530.8.1-2007 EWFA Report No: 38031900.1 Report Sponsor: Ullrich Aluminium PO BOX 246 Carole Park QLD 4300

More information

MaxiWall High-Rise External Wall System

MaxiWall High-Rise External Wall System MaxiWall High-Rise External Wall System Technical Guide Our Story With over 110 years in the timber industry, Big River is now one of Australia s largest timber manufacturing and marketing businesses,

More information

PROMATECT -S Smoke & Fire Barrier

PROMATECT -S Smoke & Fire Barrier PROMATECT -S Smoke & Fire Barrier Introduction The purpose of a cavity barrier is to prevent the spread of smoke and flame from penetrating and/or moving within a concealed space in a fire compartment.

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

qbcc queensland building and construction commission Standards & Tolerances Guide

qbcc queensland building and construction commission Standards & Tolerances Guide qbcc queensland building and construction commission Standards & Tolerances Guide Queensland May 2014 1 2 Foreword This Guide has been compiled in response to community and industry concerns that identified

More information

HP Partial Fill. Robust, long-lasting protection

HP Partial Fill. Robust, long-lasting protection 1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly

More information

REGULATORY INFORMATION REPORT

REGULATORY INFORMATION REPORT REGULATORY INFORMATION REPORT The fire resistance performance of Hilti Flexible Firestop Foam CFS-F FX / CP 660 protecting cable and cable conduit penetrations in walls and concrete floors if tested in

More information

Roof Systems. Span Tables & Thermal Ratings. Aquatek Roof Panel

Roof Systems. Span Tables & Thermal Ratings. Aquatek Roof Panel Roof Systems Aquatek Roof Panel Tables & Thermal Ratings Version 2015.02 The ultimate roofing system for highly corrosive, industrial and aquatic environments. With large spanning capabilities and a range

More information

SAFEBRIDGE HIGH PERFORMANCE ROOF INSULATION SYSTEM

SAFEBRIDGE HIGH PERFORMANCE ROOF INSULATION SYSTEM SAFEBRIDGE HIGH PERFORMANCE ROOF INSULATION SYSTEM Safebridge Key Benefits Creates a safer roof environment for workers during construction Code compliant with BCA/NCC Section J Uses the purlin space without

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum

More information

Evaluation Report For MgO Corpoation CMI-ER31004

Evaluation Report For MgO Corpoation CMI-ER31004 Evaluation Report For MgO Corpoation CMI-ER31004 Scope & Summary of Evaluation Report MgO Corp "ResCom " is an environmentally friendly all natural magnesium oxide cold ceramic sheeting. MgO Corp "ResCom

More information

BESSER BLOCK AND BRICK

BESSER BLOCK AND BRICK BESSER BLOCK AND BRICK NEW SOUTH WALES Products Type Description per MPa Fire Rating Notes m 2 Common Brick - Strength and Fire Resistance Periods (FRP) varies dependant on product. All products have a

More information

SECTION 1. AS MASONRY STRUCTURES CODE

SECTION 1. AS MASONRY STRUCTURES CODE mortarless masonry Design Manual Part 1 (AS 3700:2011) Section 1 Page: 1 SECTION 1. AS 3700 - MASONRY STRUCTURES CODE AS 3700:2011 Masonry structures is the current Australian standard for the design of

More information

INTERIOR FINISHES CHAPTER 8

INTERIOR FINISHES CHAPTER 8 CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials. 801.1.1 Interior finishes.

More information

ASSESSMENT OF AFS STRUCTURAL WALL SYSTEM FOR CBPA NSW, FEBRUARY 2008

ASSESSMENT OF AFS STRUCTURAL WALL SYSTEM FOR CBPA NSW, FEBRUARY 2008 ASSESSMENT OF AFS STRUCTURAL WALL SYSTEM FOR CBPA NSW, FEBRUARY 2008 1. Introduction This assessment of the AFS Structural Wall System is based on the following documentation provided by the supplier,

More information

Houses and Low Rise Multi-Residential External Walls PowerPanel XL. Design and Installation Guide NEW

Houses and Low Rise Multi-Residential External Walls PowerPanel XL. Design and Installation Guide NEW Houses and Low Rise Multi-Residential External Walls PowerPanel XL Design and Installation Guide NEW Contents Introduction 3 This Design Guide has been prepared as a source of information to provide general

More information

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system. Specify FILL SCM-400 for additional impact noise control when a thicker sound mat is needed. It helps achieve higher delta numbers than thinner mats. FILL SCM-400 is a cost-effective way to address Impact

More information

The Express Range. It s your home. The Express 12

The Express Range. It s your home. The Express 12 The Express Range It s your home The Express 12 Bed 3 Alfresco 4700 x 4000 The Express 12 To fit 12m frontage Bath WC Bed 2 Living / ining 4610 x 8280 24,190 Pantry Kitchen WM FR Laundry 1 2 UP LINEN Theatre

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'

More information

Cross Laminated Timber (CLT)

Cross Laminated Timber (CLT) Cross Laminated Timber (CLT) Lesson Learning Objectives To provide an awareness of the use of cross laminated timber (CLT) in multistorey construction. To develop an awareness of how CLT panels are fixed

More information

EasylationWall. External Wall Insulation System. bringing european innovation

EasylationWall. External Wall Insulation System. bringing european innovation EasylationWall External Wall Insulation System bringing european innovation EasylationWall... the new External Wall Insulation System using brick slips for stunning façades. EXTERNAL WALL INSULATION (EWI)

More information

Steel Composition: Effect on Coating Appearance, Thickness, Materials Handling and Surface Smoothness

Steel Composition: Effect on Coating Appearance, Thickness, Materials Handling and Surface Smoothness Advisory Note GEN 35/2 Steel Composition: Effect on Coating Appearance, Thickness, Materials Handling and Surface Smoothness July 2013 Hot dip galvanizing is a functional coating with superior protection

More information

Timber in Bushfire Prone Areas

Timber in Bushfire Prone Areas In many parts of Australia, the construction of new buildings and additions to existing buildings will be assessed as being in a Bushfire-prone Area. The relevant Australian Standard AS 959 provides six

More information

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT 1 East Franklin Street Phone: 301-790-4163 Third Floor Hagerstown, MD 21740 Fax: 301-791-2650 BUILDING PERMIT APPLICATION FOR RESIDENTIAL ACCESSORY

More information

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS

SOL UTIONS LIVING SOLUTIONS LIVING SOLUTIONS Buyer s Guide HOMES 1300 985 110 LIVING SUPPORT SOLUTIONS 2 BCDS0868 Contents Just imagine the space you can create 4 More reasons to choose SmartSpace 8 SmartSpace Project Planner 9 Design your SmartSpace

More information

The SIPs Process. 1 Why SIPS? What is the typical process for building a home using SIPS Industries? The Factory Process...

The SIPs Process. 1 Why SIPS? What is the typical process for building a home using SIPS Industries? The Factory Process... 30a Renewable Chase Bibra Lake WA 6163 Tel: (08)9494 2211 Fax: (08)9494 2202 Email: info@sipsindustries.com.au Web: www.sipsindustries.com.au The SIPs Process Contents 1 Why SIPS?... 2 1.1 Energy Efficiency...

More information

Duro-Last Roofing, Inc. 525 Morley Drive Saginaw, MI 48601

Duro-Last Roofing, Inc. 525 Morley Drive Saginaw, MI 48601 DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT Housing - Federal Housing Commissioner Series and Series Number: MATERIALS RELEASE NO: (Supersedes issue dated December 14, 2006) 1223f TO: DIRECTORS, SINGLE

More information

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System

BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System EXPIRES MAR 2018 BEAL Appraisal Certificate The PLASTERCRETE AAC Wall Panel System Product 1.1 The PLASTERCRETE NZ AAC Wall Panel System (PAWPS) is a drained and ventilated masonry veneer wall cladding

More information

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY BRANZ Appraisals Technical Assessments of products for building and construction. Product 1.1 is a self-adhesive, synthetic underlay for use over rigid wall

More information

BC BUILDING CODE ERRATA

BC BUILDING CODE ERRATA BC BUILDING CODE ERRATA The following changes should be made to print and offline copies of the 2012 BC Codes. The 2012 BC Codes subscription products include these changes. Highlighted text is used in

More information

Stramit Patio Roofing Cyclonic Span Tables

Stramit Patio Roofing Cyclonic Span Tables Stramit Patio Roofing Cyclonic Span Tables 1 Stramit Patio Roofing Profiles How to use the tables Step 1 Determine whether the patio is monoslope or pitched. Stramit Sunset Patio Roof Panel Concealed Fixed

More information

Abu Dhabi Certification Scheme for Ceiling and Wall Board Products

Abu Dhabi Certification Scheme for Ceiling and Wall Board Products Abu Dhabi Certification Scheme for Ceiling and Wall Board Products Assessment and Surveillance Plan Page i Amendment Page To ensure that each controlled copy of this ASP contains a complete record of amendments,

More information

External Wall Insulation Systems GUARANTEED TO PERFORM!

External Wall Insulation Systems GUARANTEED TO PERFORM! External Wall Insulation Systems GUARANTEED TO PERFORM! External Wall Insulation Systems The wrap-around solution for warmer homes, lower bills Soaring energy costs have brought the need for more effective

More information

CCMC MgO Board Advisory

CCMC MgO Board Advisory CCMC MgO Board Advisory July 2017 Dear Building Officials, CCMC was recently made aware of premature failures in other countries of some magnesium oxide (MgO) boards. Due to the increased use of MgO boards

More information

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017 SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE Amended 28 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Sika (NZ) Ltd PO Box 19 192 Avondale Auckland 1746

More information

Lysaght Bondek. Structural steel decking system Design and Construction Manual

Lysaght Bondek. Structural steel decking system Design and Construction Manual Lysaght Bondek Structural steel decking system Design and Construction Manual Excellent spanning capacities for greater strength and less deflection Acts as permanent formwork with minimal propping and

More information

ENVIRONMENTAL PRODUCT DECLARATION

ENVIRONMENTAL PRODUCT DECLARATION ENVIRONMENTAL PRODUCT DECLARATION LN: THS - 2008 Thermoshield Australia Pty Ltd Standard: GECA 23-2005 Architectural and Protective Coatings Conformance Declaration Date: 18th December 2008 Assurance ensuring

More information

System Recommendation SR0618

System Recommendation SR0618 Ardex Australia Pty Ltd ABN 82 000 550 005 Unit 7, 20 Powers Road, Seven Hills NSW 2147 Australia Telephone + 61 2 9851 9100 Facsimile +61 2 9838 7970 www.ardexaustralia.com System Recommendation SR0618

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 4417.1 Australian/New Zealand Standard Marking of electrical products to indicate compliance with regulations Part 1: General rules for use of the mark This Joint Australian/New Zealand Standard

More information

Fire protecting windows close to boundaries

Fire protecting windows close to boundaries Fire protecting windows close to boundaries product solutions Q1 Queensland Hyundai Head Office Sydney Digital Life Labs Melbourne ANZ Head Office Melbourne Stockhome, Stocklands HQ Sydney T: 1300 655

More information

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES UL Evaluation Report UL ER18920-01 Issued: August 15, 2014 Visit UL s On-Line Certifications Directory: www.ul.com/erdirectory for current status of Report. UL Category Code: ULEX CSI MasterFormat DIVISION:

More information

(Project Location) (your firm's name)

(Project Location) (your firm's name) SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections

More information