PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory

Size: px
Start display at page:

Download "PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory"

Transcription

1

2 PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory January Product Description Metacaulk BOX GUARD is a one component fire rated pad for use in electrical boxes. It is inserted on the inside back wall of an electrical box, and is a highly intumescent firestop material. When exposed to fire, Metacaulk BOX GUARD will expand forming a char that will seal off the opening and prevent the spread of flames and limit the temperature rise on the unexposed surfaces. Metacaulk BOX GUARD is applied by hand, and must comply with NEC (formerly ) or other applicable codes. U.S. Patent No. 6,207,085 & 6,252,167. Metacaulk BOX GUARD Features * Easy to Install * Cost Effective * Highly Intumescent * Adheres to Back of Electrical Box * Non-Conductive * Dielectric Breakdown Voltage 22V/mil (ASTM D 149) 2. Material Properties Asbestos Fillers Solvents Hazardous Ingredients None None None Sizes (Approx.) Single box: 1 13/16" x 2 13/16" x 1/4" 47 mm X 71 mm x 6 mm Double box (two sizes) 1) 3 11/16" x 3 3/4" x 1/4" 94 mm x 95 mm x 6 mm 2) 4 3/8" x 4 3/8" x 1/4" 111 mm x 111 mm x 6 mm Color Black ASTM E 84, UL 723 Tunnel Test Flame Spread 5 Smoke Index 5 Sound Transmission Class STC Rating 55* *Tested in a UL 411 wall assembly/section to ASTM E90 3. Applications Use Metacaulk BOX GUARD on inside back panel of electrical boxes to maintain the integrity of fire rated wall assemblies restricting the passage of flames and limiting the temperature rise on the unexposed surfaces. When Metacaulk Box GUARD is used as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 inches. 4. Installation Instructions Metacaulk BOX GUARD is easy to install. Make sure rear surface is clean, dry and not contaminated. Remove protective paper from tape and stick pad to inside back wall of electrical box*. Center pad from top and bottom of box. Install switch, or outlet. Use the single pad for a single box (2" x 4"), and double pad for double box 4" x 4", and 4 3/8" x 4 3/8" pad for 4 11/16" x 4 11/16"box. Make sure installation complies with NEC (formerly ) or other applicable codes. Consult UL Directory for complete instructions and system listings. *If necessary, a maximum 3/8" hole may be created or the pad may be slit from one edge to allow easier access to the electrical box ground screw. 5. Testing Data Metacaulk BOX GUARD is classified by Underwriters Laboratories, Inc. under Wall Opening Protective Material as found in the Fire Resistance Directory. For specific test criteria see UL Fire Resistance Directory or call REC- TORSEAL.

3 METACAULK BOX GUARD Metacaulk BOX GUARD was tested at positive pressure for a minimum.01 inches of water. The basic standard used to investigate products is UL 263/ ASTM E-119, "Fire Tests of Building Construction and Materials". Complies to Required Environmental Exposure Testing of Accelerated Aging and High Humidity as per UL 1479 Fire Test of Through-Penetration Firestops. 6. Storage & Handling Metacaulk BOX GUARD should be stored in a cool, dry place. Keep products stored under protective cover, in their original containers. A stock rotation program is recommended. 7. Availability Metacaulk BOX GUARD is available as pads measuring, single 1 13/16" x 2 13/16" x 1/4" (47 mm x 71 mm x 6 mm) and two double pads, one measuring 3 3/4" x 3 11/16" x 1/4" (94 mm x 95 mm x 6 mm) and one measuring 4 3/8" x 4 3/8" x 1/4" (111 mm x 111 mm x 6 mm). 8. Limitations To be used only in the tested configurations or as recommended by RectorSeal. 9. CAUTIONS FOR CHEMICAL EMERGEN- CY, SPILL, LEAK, FIRE, EX- POSURE OR ACCIDENT, CALL CHEMTREC - DAY OR NIGHT PRECAUTIONS: Do not take internally. May be harmful if swallowed. May cause eye and skin irritation if prolonged or repeated contact occurs. Wash after handling. FIRST AID: For any overexposure, get immediate medical attention after first aid is given. Eyes- Flush 15 minutes with clean water. Skin-Wash with soap and water. Ingestion-Only if conscious, give large amounts of water and call physician. FIRE AND SPILLS: Use water fog, CO 2, foam, or dry chemicals. Wipe up spills to prevent footing hazard. Clean up with scrapers and water. STORAGE AND HANDLING: Store away from heat sources. KEEP OUT OF REACH OF CHILDREN. For additional information, refer to Material Safety Data Sheet. For additional technical service, call: Fax: RECTORSEAL 2601 Spenwick Drive Houston, Texas NOTE: Not to be used on plastic boxes. For additional information refer to UL Directory. Retain a copy of the Product Data Sheet for review by the Inspector. 10. LIMITED WARRANTY RectorSeal makes the Limited Express Warranty that when the instructions for storage and handling of our products are followed we warrant our products to be free from defects. THIS LIMITED EXPRESS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY OTHER OBLIGATION ON THE PART OF RECTORSEAL. The sole remedy for breach of the Limited Express Warranty shall be the refund of the purchase price. All other liability is negated and disclaimed, and RectorSeal shall not be liable for incidental or consequential damages. Suggestions and recommendations covering the use of our products are based on our past experience and laboratory findings. However, as we have no control as to the methods and conditions of application, we only assume responsibility for the uniformity of our products within manufacturing tolerances. A-11

4 Issued to: RECTORSEAL 2601 SPENWICK DR HOUSTON, TX USA This is to certify that representative samples of Wall-opening Protective Materials Metacaulk Fire Rated Putty Pads, Metacaulk Box Guard Inserts and Metacaulk Cover Guard Gaskets. See Addendum Page Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: ANSI/UL 263, "Fire Tests of Building Construction and Materials." See the UL Online Certifications Directory at for additional information Only those products bearing the UL Classification Mark should be considered as being covered by UL s Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle: with the word CLASSIFIED (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL s evaluation of the product; and the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 1 of 8

5 Metacaulk Box Guard Inserts for use with max 2-1/8 by 4 by 2-1/8 in deep. flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 47 mm wide by 71 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical code, (NFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4 by 4 by 2-1/8 in deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4-1/2 by 8-1/2 by 1-5/8 in deep. flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in.deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Two 94 mm wide by 95 mm high inserts are evenly spaced and adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Min 3/4 in. deep plaster rings installed over outlet box. After installation of gypsum board, nom 1/4 in. thickness of RectorSeal Metacaulk 1000 or Biostop 500+ Sealant, bearing the UL Classification Marking for Fill, Void or Cavity Materials, applied between the base layer of wallboard and the plaster ring. Outlet boxes installed with steel cover plates. When protective material is used within and around outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4 by 4 by 1-1/2 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in.deep wood studs and with max 4 by 4 by 2-1/8 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in.deep steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with plastic cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with 4-11/16 by 4-11/16 by 2-1/8 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in.deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with plastic or steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with 4-11/16 by 4-11/16 by 2-1/8 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 3-3/4 by 5-1/2 by 2-1/2 in deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel or wood studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high and one 47 mm wide by 71 mm high inserts adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with 4-3/8 by 4-7/8 by 2-1/4 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and

6 combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with plastic or steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts, for use with 4-3/8 by 4-7/8 by 2-1/4 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4-11/16 by 4-11/16 by 2-1/8 in. flush device UL Listed Metallic Outlet Boxes installed with steel mud rings and plastic or steel cover plates in 1 h or 2 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 3-1/2 in. thick fiberglass (min 0.5 pcf) or mineral wool (min 4.0 pcf) batt insulation is to be installed within the wall cavity. One 4-3/8 by 4-3/8 in. insert adhered to the interior back wall of the outlet box in accordance with the instructions supplied with the product. Installation to comply with the National Electrical Code (NFPA 70). When protective material is used within outlet boxes on both sides of the wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4-11/16 by 4-11/16 by 2-1/8 in. flush device UL Listed Metallic Outlet Boxes installed with steel mud rings and plastic or steel cover plates in 1 h fire rated gypsum board wall assemblies framed with min 6 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Nom 6-1/2 in. thick fiberglass insulation (min 0.5 pcf) is to be installed within the wall cavity. One 4-3/8 by 4-3/8 in. insert adhered to the interior back wall of the outlet box in accordance with the instructions supplied with the product. Installation to comply with the National Electrical Code (NFPA 70). When back to back boxes are inter connected a 1/4 in. depth of Metacaulk 1000 in the open end of each conduit of the box. UL does not furnish a detail drawing for these listings

7 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Metacaulk Fire Rated Putty Pads for use with max 4 by 4 in. flush device UL Listed Metallic Outlet Boxes installed with steel cover plates in 1 and 2 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) and completely seal against the stud within the stud cavity. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Fire Rated Putty Pads for use with max 2-3/16 by 3-3/4 by 2-11/32 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Pass & Seymour Inc. under the tradename Slater, made from polyvinyl chloride and bearing a 2 h rating under the "Outlet Boxes and Fittings Classified for Fire Resistance" category in the Fire Resistance Directory. Putty pads and boxes for use in 2 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. Outlet box secured to studs by means of mounting tab supplied with the outlet box. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box including the side of the outlet box against the stud. Outlet boxes installed with steel or plastic cover plates. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk fire Rated Putty Pads for use with max 4 by 4 in. flush device UL Listed Metallic Outlet Boxes Installed with steel or plastic cover plates in 1 h fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Two layers of min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box including the side of the outlet box against the stud. Nom 1/2 in. plaster rings installed over outlet boxes. After installation of gypsum board, nom 1/4 in. thickness of RectorSeal Metacaulk 1000 or Biostop 500+ Sealant, bearing the UL Classification Marking for Fill, Void or Cavity Materials, applied between gypsum board and the plaster ring. When moldable putty pad outlet box protective material and fill material are used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 2 of 8

8 Metacaulk Box Guard Inserts for use with max 2-1/8 by 4 by 2-1/8 in deep. flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 h fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 47 mm wide by 71 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical code, (NFPA 70). Outlet boxes installed with steel cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4 by 4 by 2-1/8 in deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Fire Rated Putty Pads for use with max 4 by 3-3/4 by 3 in. deep UL Listed Nonmetallic Outlet Boxes manufactured by Carlon Electrical Products, made from polyvinyl chloride, and bearing a 2 hr rating under the "Outlet Boxes and Fittings Classified for Fire Resistance" category in the Fire Resistance Directory. Putty pads and boxes for use in 1 and 2 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood studs and constructed of the materials and in the manner specified in the individual U300 Series Wall and Partition Designs in the Fire Resistance Directory. Outlet box secured to wood stud by means of two nailing tabs in conjunction wit nails supplied with the outlet box. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box (except for the side of the outlet box against the stud) including the nailing tab and completely seal against the stud within the stud cavity. Outlet boxes installed with steel or plastic cover plates. When moldable putty pad outlet box protective material is used on boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 3 of 8

9 Metacaulk Box Guard Inserts for use with max 4-1/2 by 8-1/2 by 1-5/8 in deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Two 94 mm wide by 95 mm high inserts are evenly spaced and adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Min 3/4 in. deep plaster rings installed over outlet box. After installation of gypsum board, nom 1/4 in. thickness of RectorSeal Metacaulk 1000 or Biostop 500+ Sealant, bearing the UL Classification Marking for Fill, Void or Cavity Materials, applied between the base layer of wallboard and the plaster ring. Outlet boxes installed with steel cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within and around outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4 by 4 by 1-1/2 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood studs and with max 4 by 4 by 2-1/8 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with plastic cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Cover Guard Gaskets for use with max 4-11/16 by 4-11/16 in. flush device UL Listed Metallic Outlet Boxes installed with steel or plastic cover plates in 2 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. Nom 2 by 4 in. or 4 by 4 in. gaskets to be installed on the inside of single gang or double gang cover plates, respectively, prior to attachment to device. Installation to comply with the National Electrical Code, (NFPA 70). When protective material is used within cover plates on outlet boxes on each sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided the boxes are not installed back-to-back. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 4 of 8

10 Metacaulk Cover Guard Gaskets for use with max 4-11/16 by 4-11/16 in. flush device UL Listed Metallic Outlet Boxes installed with steel or plastic cover plates in 1 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 4 in. thick fiberglass (min 0.5 pcf) or mineral wool (min 4.0 pcf) batt insulation is to be installed within the wall cavity. Nom 2 by 4 in. or 4 by 4 in. gaskets to be installed on the inside of single gang or double gang cover plates, respectively, prior to attachment to device. Installation to comply with the National Electrical Code, (NFPA 70). When protective material is used within cover plates on outlet boxes on each sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided the boxes are not installed back-to-back. Metacaulk Cover Guard Gaskets for use with max 4-11/16 by 4-11/16 in. flush device UL Listed Metallic Outlet Boxes installed with Decora style steel or plastic cover plates in 1 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 4 in. thick fiberglass (min 0.5 pcf) or mineral wool (min 4.0 pcf) batt insulation is to be installed within the wall cavity. Nom 4 by 4 in. gaskets to be installed on the inside of double gang cover plates prior to attachment to device. Installation to comply with the National Electrical Code, (NFPA 70). When protective material is used within cover plates on outlet boxes on each sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with 4-11/16 by 4-11/16 by 2-1/8 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with plastic or steel cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 5 of 8

11 Metacaulk Box Guard Inserts for use with 4-11/16 by 4-11/16 by 2-1/8 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 3-3/4 by 5-1/2 by 2-1/2 in deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep steel or wood studs and constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 94 mm wide by 95 mm high and one 47 mm wide by 71 mm high inserts adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with 4-3/8 by 4-7/8 by 2-1/4 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 1 hr fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with plastic or steel cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 6 of 8

12 Metacaulk Box Guard Inserts for use with 4-3/8 by 4-7/8 by 2-1/4 in. deep flush device UL Listed Metallic Outlet Boxes without internal clamps in 2 hr fire rated gypsum board wall assemblies framed individual U400 Series Wall and Partition Designs in the Fire Resistance Directory. One 111 mm wide by 111 mm high insert adhered to the interior back wall of the outlet box in accordance with the installation instructions supplied with the product. Smaller sized inserts may be cut and combined to achieve the 111 mm by 111 mm coverage and adhered to the interior back wall of the outlet box. Installation to comply with the National Electrical Code, (NFPA 70). Outlet boxes installed with steel cover plates. A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4-11/16 by 4-11/16 by 2-1/8 in. flush device UL Listed Metallic Outlet Boxes installed with steel mud rings and plastic or steel cover plates in 1 h or 2 h fire rated gypsum board wall assemblies framed with min 3-1/2 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 3-1/2 in. thick fiberglass (min 0.5 pcf) or mineral wool (min 4.0 pcf) batt insulation is to be installed within the wall cavity. One 4-3/8 by 4-3/8 in. insert adhered to the interior back wall of the outlet box in accordance with the instructions supplied with the product. Installation to comply with the National Electrical Code (NFPA 70). A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When protective material is used within outlet boxes on both sides of the wall as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be less than 24 in. provided that the boxes are not installed back-to-back. Metacaulk Box Guard Inserts for use with max 4-11/16 by 4-11/16 by 2-1/8 in. flush device UL Listed Metallic Outlet Boxes installed with steel mud rings and plastic or steel cover plates in 1 h fire rated gypsum board wall assemblies framed with min 6 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Nom 6-1/2 in. thick fiberglass insulation (min 0.5 pcf) is to be installed within the wall cavity. One 4-3/8 by 4-3/8 in. insert adhered to the interior back wall of the outlet box in accordance with the instructions supplied with the product. Installation to comply with the National Electrical Code (NFPA 70). A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. When back to back boxes are inter connected a 1/4 in. depth of Metacaulk 1000 in the open end of each conduit of the box. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 7 of 8

13 Metacaulk Box Guard Inserts for use with max 4-11/16 by 4-11/16 by 2 1/8 in. flush device UL Listed Metallic Outlet Boxes installed with steel mud rings and plastic or steel cover plates in 1 h or 2 h fire rated gypsum board wall assemblies framed with min 5-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. One 4-3/8 by 4-3/8 in. insert adhered to the interior back wall of the outlet box in accordance with the instructions supplied with the product. Installation to comply with the National Electrical Code (NFPA 70). A max 3/8 in. diam opening at one edge may be provided to permit access to the electrical box ground screw. Boxes may be installed within the same stud cavity, back-toback. When back-to-back boxes are inter connected, a min 1/4 in. thickness formed plug of Putty Pad or Metacaulk 1000 shall be installed in the open end of each conduit of the box. Metacaulk Fire Rated Putty Pads for use with max 4-11/16 by 4-11/16 by 2-1/8 in. flush device UL Listed Metallic Outlet Boxes installed with steel mud rings and plastic or steel cover plates in 2 h fire rated gypsum board wall assemblies framed with min 5-1/2 in. deep steel studs and constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box including the side of the outlet box against the stud. Installation to comply with the National Electrical Code (NFPA 70). Boxes may be installed within the same stud cavity, back-to-back. When back-to-back boxes are inter connected, a min 1/4 in. thickness formed plug of Putty Pad or Metacaulk 1000 shall be installed in the open end of each conduit of the box. Metacaulk Fire Rated Putty Pads for use with max 4-11/16 by 4-11/16 by 2-1/8 in. flush device UL Listed Metallic Outlet Boxes installed with steel mud rings and plastic or steel cover plates in 1 h fire rated gypsum board wall assemblies framed with min 6 in. deep wood or steel studs and constructed of the materials and in the manner specified in the individual U300, U400 or V400 Series Wall and Partition Designs in the Fire Resistance Directory. Nom 6-1/2 in. thick fiberglass insulation (Min 0.5 pcf) is to be installed within the wall cavity. Min 1/8 in. thick moldable putty pads are to be installed to completely cover the exterior surfaces of the outlet box including the side of the outlet box against the stud. Installation to comply with the National Electrical Code (NFPA 70). When back to back boxes are inter connected a 1/4 in. thickness formed plug of Putty Pad or Metacaulk 1000 in the open end of each conduit of the box. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. For questions, please Page 8 of 8

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes 3 Fire Barrier Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes This information brochure highlights requirements for UL listed, fire-rated electrical boxes located in some UL

More information

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet 3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet 1. Product Description 4 in. x 8 in. (101.6 mm x 203.3 mm), 7 in. x 7 in. (177.8 mm x 177.8 mm) and 9.5 in. x 9.5 in. (241.2 mm x 241.3 mm) pad

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Manufacturer's Representative: Rectorseal - Technical Services Ph (713) 263-8001

More information

System No. C-AJ-8133

System No. C-AJ-8133 System No. C-AJ-8133 March 09, 2011 F Ratings - 1, 1-1/2, 2 and 3 Hr (See Item 2) T Ratings - 0, 1/2, 3/4, 1, 1-1/2, 2 and 3 Hr (See Item 2) 1. Floor or Wall Assembly Min 4-1/2 in. (114 mm) thick reinforced

More information

Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) en español Hilti Firestop Systems Guide 2007

Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) en español Hilti Firestop Systems Guide 2007 Product Information CP 617, CP 617L & CP 617XL Firestop Putty Pad Chapter Tabs Chapter Tabs Product description A moldable firestop putty designed to help protect electrical outlet boxes Product features

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Waterproof Contractor Submittal (Joint Strip) Manufacturer's Representative: Rectorseal

More information

System No. C-AJ-8048

System No. C-AJ-8048 System No. C-AJ-8048 F Rating - 2 Hr T Ratings - 0, 1/2, 3/4, 1 and 1-1/2 Hr (See Item 2) L Rating At Ambient Less Than 1 CFM / Sq. Ft. L Rating At 400 F 5 CFM / Sq. Ft. System No. C-AJ-8048 System No.

More information

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products System No. C-AJ-8073 September 07, 2004 F Rating 2 Hr T Ratings 0, 3/4 and 2 Hr C-AJ-8073 1 of 5 1. Floor or Wall Assembly Min 4-1/2 in. thick reinforced normal weight (140-150 pcf) concrete. Wall may

More information

RSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP

RSIC-1-INSTALALTION GUIDE RSIC-1 SOUND ISOLATION CLIP RSIC-1 Drywall Furring Channel: Minimum Requirements: 25 gauge, hemmed edge detail required on all 25 gauge furring channel. Meets or exceeds SFIA requirements. Depth: 7/8 inch Width Bottom: 2-9/16 to

More information

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade Fire Protection Products Firestop Submittal Package FIP 1-Step Firestop Foam Electrical Trade Manufacturer: Fire Protection Products Ryan Fenstermaker 732.921.1503 rfenstermaker@mmm.com Electrical Products

More information

3M Fire Barrier Pass-Through Device Product Description

3M Fire Barrier Pass-Through Device Product Description Product Data Sheet 3M Fire Barrier Product Description The 3M Fire Barrier is a one-piece hinged metal enclosure designed to prevent the passage of fire and smoke. The metal device has a fixed firestopping

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Gypsum board screw attached to wood framing and furring members, joint treatment, and accessories. 2. Installation of

More information

System No. HW-D-0119

System No. HW-D-0119 System No. HW-D-0119 August 03, 2007 Assembly Rating 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 1 In. Class II and III Movement Capabilities 100% Compression or Extension 1. Floor Assembly The fire-rated

More information

TECHNICAL DATA SHEET ASMACO INTUMESCENT ACRYLIC SEALANT

TECHNICAL DATA SHEET ASMACO INTUMESCENT ACRYLIC SEALANT TECHNICAL DATA SHEET ASMACO INTUMESCENT ACRYLIC SEALANT (HIGH PERFORMANCE GUN GRADE INTUMESCENT FIRE-STOP ACRYLIC SEALANT) DESCRIPTION: ASMACO INTUMESCENT ACRYLIC SEALANT is a single component high performance

More information

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325)

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325) FIRESTOP TECHNICAL PACK FIRESEAL 814 Acrylic Intumescent Caulk Polymer Adhesives Sealant Systems, Inc. 501 Garrett Morris Parkway Mineral Wells, TX 76067 TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL

More information

PARKING PLAZA MEXICO COVERED GAS PUMP ISLAND PARKING BUS PARKING AREA. The Evans Group COVERD AREA TACO STAND COVERD AREA AREA FREEZER EXIT EXIT

PARKING PLAZA MEXICO COVERED GAS PUMP ISLAND PARKING BUS PARKING AREA. The Evans Group COVERD AREA TACO STAND COVERD AREA AREA FREEZER EXIT EXIT OFFICE FUEL ISLAND ATTENDANTS OFFICE GAS PUMP ISLAND BUS SIGNAGE AND 6'-0" WALL TACO STAND COVERED RESTROOMS RESTROOMS MARKET TACO STAND PLAZA MEXICO COVERED FREEZER GAS PUMP ISLAND BUS FUEL ISLAND ATTENDANTS

More information

3M Fire Protection Products 3M Interam Endothermic Mat For Commercial Buildings

3M Fire Protection Products 3M Interam Endothermic Mat For Commercial Buildings 3M Fire Protection Products For Commercial Buildings Tested in accordance with AS1530.4-005 Get wrapped up in opens up new opportunities in building design, allowing architects to fulfill the UL mark of

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Commercial Plumbing Contractors (PVC & PEX Thru Gyp Board) Manufacturer's Representative:

More information

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax: JB ENGINEERING AND CODE CONSULTING, P.C. 1661 Cardinal Drive Munster, IN 46321 Phone: 219-922-6171 Fax: 219-922-6172 E-Mail: JBEngineer@aol.com JULIUS A. BALLANCO, P.E. President January 15, 2008 Mr. Rick

More information

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM U.L. FIRE RATED Head-of-Wall Joint Systems 1-800-275-2279 STEELER INC. SLOTTED STUD 1-800-275-2279 The STEELER SLOTTED STUD is an innovative

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Drywall Contractor Submittal - Sealant & Blazefoam Manufacturer's Representative:

More information

RSIC-V RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP

RSIC-V RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP RSIC-V INSTALLATION GUIDE RSIC-V PAC International, Inc. Tel: (866) 774-2100 Fax: (866) 649-2710 Web Site: www.pac-intl.com Furring Channel: Minimum requirements: 25 gauge, hemmed edge detail required

More information

RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP. PAC International, Inc. Tel: (866) Fax: (866) Web Site:

RSIC-V INSTALLATION GUIDE RSIC-V SOUND ISOLATION CLIP. PAC International, Inc. Tel: (866) Fax: (866) Web Site: RSIC-V INSTALLATION GUIDE RSIC-V Furring Channel: Minimum requirements: 25 gauge, hemmed edge detail required on all 25 gauge furring channel. Meets or exceeds SFIA min. requirements. (25 Ga furring channel

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIRESTOP SUBMITTAL PACKAGE PLUMBING Materials FS-ONE Intumesent Caulk Includes: Technical and Installation Data UL Certificate of Compliance LEED information MSDS UL Details Gypsum Wall Assemblies W-L-1054

More information

The System U.S. Patent No. 5,913,788

The System U.S. Patent No. 5,913,788 The System U.S. Patent No. 5,913,788 UL System No. HW-D-0027 2 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0028 1 Hour Rated Assembly (Metal Decking) UL System No. HW-D-0208 1 Hour Rated Assembly

More information

3M Fire Barrier Pillows Product Description

3M Fire Barrier Pillows Product Description Product Data Sheet 3M Fire Barrier Product Description Product Features Graphite free composition Available in three sizes Easy to install The 3M Fire Barrier Pillow is a self-contained, highly intumescent

More information

System No. C-AJ-8096

System No. C-AJ-8096 F Rating -- Hr T Rating -- 0, / and Hr (See Item ) B B E E G G F F A A C C D D 4B 4A SECTION A-A SECTION B-B July 0, 005 Page: of 5 F Rating -- Hr T Rating -- 0, / and Hr (See Item ) B A SECTION C-C SECTION

More information

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS SECTION 07841 - THROUGH-PENETRATION FIRESTOP SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

FIRESTOP SUBMITTAL PACKAGE

FIRESTOP SUBMITTAL PACKAGE FIRESTOP SUBMITTAL PACKAGE 200 Evans Way Somerville, NJ 08876 (800) 992-1180 (908) 526-8000 Fax (908) 526-9623 SPECIFIED TECHNOLOGIES INC. THE FIRESTOPPING SPECIALISTS Mechanical Wood Floor-Ceilings SYSTEM

More information

3M Fire Barrier Mouldable Putty

3M Fire Barrier Mouldable Putty 3M Technical Data Sheet 3M Fire Barrier The 3M Fire Barrier consists of a synthetic elastomer designed for use as a one part, intumescent fire resistive putty used to restore the integrity of fire rated

More information

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount) INSTALLATION MANUAL FOOTWALL/SINKWALL (floor mount) OVERVIEW The Form is a UL-listed configurable footwall/sinkwall system. This system can include any combination of base cabinets, upper cabinets, wardrobes,

More information

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.V481 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

DECEMBER Phone: Fax:

DECEMBER Phone: Fax: DECEMBER 007 TM system components www.nsiindustries.com Phone: 800.1.587 Fax: 800.81.5566 Table of Contents FireStop System Components Intumescent Caulk...1 Silicone...1 Silicone SL... FireStop81.... FireBlock16...

More information

RSIC-1 SOUND ISOLATION SYSTEMS RSIC-1 INSTALLATION GUIDE

RSIC-1 SOUND ISOLATION SYSTEMS RSIC-1 INSTALLATION GUIDE RSIC-1 INSTALLATION GUIDE PAC International, Inc. Tel: (866) 774-2100 Technical: (866) 649-2710 Web Site: www.pac-intl.com RSIC is a registered Trade Mark of PAC International, Inc. Page 1 Drywall Furring

More information

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION 07 84 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

St. Monica Food Pantry

St. Monica Food Pantry St. Monica Food Pantry 07 8400-1 SECTION 07 8400 - FIRESTOPPING PART 1 - GENERAL 1.1 SUMMARY: A. Related work: 1. Concrete. 2. Mortar and grout. 3. Brick masonry. 4. Concrete unit masonry. 5. Structural

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): WP Contractors - Concrete Control Joints - BF 750 Manufacturer's Representative:

More information

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) 3" RESILMOUNT A237R SPECIFICATIONS 1d " f" Width...1.375 inch Height...3.25 inch Depth...1.125 inch Weight....025

More information

SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass

SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass This GGI Specification was prepared as an aid to specifiers preparing written construction documents. For specification assistance with specific product applications, please contact GGI. To download an

More information

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

SUBMITTAL INDEX. Product Datasheets: Product Approvals: Product Datasheets: HFP Pro Series Sleeve RevA HFP CD Plates RevA HFP Sleeve Extenions RevA HFP Water Dam RevA HFP Water Module RevA HFP Hollow Sleeve RevB HFP Cable Line Set RevA HFP Closet Flange RevA

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.

More information

Fire Protection Products

Fire Protection Products wwww Fire Protection Products Product Data Sheet April / 2017 Product Description Product Features Applications Specifications 3M Fire and Water Barrier Tape is a self-adhered membrane that provides a

More information

3M CS-195+ Composite Sheet Product Description

3M CS-195+ Composite Sheet Product Description Product Data Sheet 3M Product Description 3M Fire Barrier is a one-part composite system comprised of four components. The heart of the system is an organic/ inorganic, fire-resistive elastomeric sheet.

More information

RAY-CORE Structural Insulated Roof and Wall Panels

RAY-CORE Structural Insulated Roof and Wall Panels SUBMITTAL 20180101 RAY-CORE Structural Insulated Roof and Wall Panels Closed Cell Polyurethane Foam Insulation Douglas Fir Studs STANDARD FEATURES Insulation, Framing and Wrap in a 4 wide panel Available

More information

AUTHORIZATION TO MARK

AUTHORIZATION TO MARK AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set

More information

SOUND SEAL 90 DRAFT / SMOKE / ACOUSTICAL SOUND SEALANT

SOUND SEAL 90 DRAFT / SMOKE / ACOUSTICAL SOUND SEALANT PRODUCT NAME MANUFACTURER PRODUCT DESCRIPTION Sound Seal 90 Everkem Diversified Products 5180 Indiana Avenue, Winston Salem, NC 27106 PH: 1-800-638-3160 FAX: (336) 661-7969 Sound Seal 90 is a high quality

More information

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631 Page Bottom XHBN.HW-D-0631 Joint Systems Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering

More information

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips) Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips) 1d" 2 2" 1 4" f" QUIETCLIP SPECIFICATIONS Width...1.25 inch Height...4.25 inch Depth...1 inch Weight....025 lbs Max Spacing...48

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

Duct Wrap Flexible Wraps

Duct Wrap Flexible Wraps Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone

More information

GC-X360S-W GC-X360S-B

GC-X360S-W GC-X360S-B GC-X360S-W GC-X360S-B Game Console Security Cover for Xbox 360S 1 date:01/22/13 #:125-9401 WARNING ENG - This product was designed to be installed on wood stud, solid concrete or cinder block walls. Before

More information

SECTION 3. Sec 3 TECHNICAL DATA SHEET. Cleaners / Strippers. Citrus Cleaner J Green Bean Clean

SECTION 3. Sec 3 TECHNICAL DATA SHEET. Cleaners / Strippers. Citrus Cleaner J Green Bean Clean SECTION PRODUCT PAGE Citrus Cleaner J48... - Green Bean Clean... -5-1 Citrus Cleaner J48 DESCRIPTION Citrus Cleaner J48 is a heavy duty concrete stripper and degreaser that is used for general cleaning

More information

Fire Protection Products

Fire Protection Products Fire Protection Products Product Data Sheet January / 2017 Product Description Product Features Applications Specifications is a sprayable, moisture-curing hybrid siliconized polymer that forms a tough,

More information

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips) Installation Guide and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86 inch Weight....025 lbs Max Spacing...48

More information

Installation Guide and Safety Manual

Installation Guide and Safety Manual Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) REQUIRED FURRING CHANNEL REQUIRED FURRING CHANNEL* 1 4" 2 2" Minimum f" Gauge:...25 Gauge With Hemmed Edge (Do Not

More information

OUTLET PUTTY PADS SPECIFICATIONS

OUTLET PUTTY PADS SPECIFICATIONS PART 1 - GENERAL OUTLET PUTTY PADS SPECIFICATIONS SECTION 07840 - FIRESTOPPING 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada LISTING INFORMATION OF Mitek Design No. MCI/WI 60-02 SPEC ID: 27680 MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada This report is for the exclusive use of Intertek s Client and is provided

More information

RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications:

RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications: RSIC-1 The RSIC-1 is designed for use with any wood framed, steel framed, CMU, or concrete wall and ceiling system where noise control is needed. The RSIC-1 assembly decouples and isolates the gypsum board

More information

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848 International Fireproof Technology Inc. 17528 Von Karman Avenue Irvine, CA 92614 This report is for the exclusive

More information

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual FORM FOOTWALL (floating) Installation Manual FORM FOOTWALL (floating) OVERVIEW The Form is a UL-listed configurable footwall system. This system can include any combination of base cabinets, upper cabinets,

More information

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263 Page 1 of 7 Page Bottom BXUV.U415 Fire Resistance Ratings - ANSI/UL 263 Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U415 July 30,

More information

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

EPV Pellet Vent Pellet Stove Venting System Installation Instructions EPV Pellet Vent Pellet Stove Venting System Installation Instructions A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE

More information

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007 research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP81-1 1981 REVISION 2007 American Iron and Steel Institute Fire Resistance Ratings

More information

UL Design System HW-D-1012 continued

UL Design System HW-D-1012 continued UL System No. HW-D-1012 Assembly Ratings 1, 2 and 3 Hr (See Item 2) Nominal Joint Width 3 in. Class II and III Movement Capabilities 100% Compression or Extension Page 1 of 5 1. Floor Assembly The fire-rated

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Interior gypsum wallboard. 2. Tile backing panels. B. Related Sections: 1. Section 012300 Alternates. 1.2 SUBMITTALS A.

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please

More information

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL Model # Series 7200-S Top Mounting Plate Electrical Junction Box Located Behind Removable Upper Panel Medical Gas Connections Lower Mounting Plate OVERVIEW

More information

Fire Barrier Duct Wrap 615+

Fire Barrier Duct Wrap 615+ Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

installation instructions Combination Fire & Smoke Damper

installation instructions Combination Fire & Smoke Damper Combination Fire & Smoke Damper Sleeve Fire Rated Partition Retaining Angle Combination Fire & Smoke Damper Actuator General Notes: Combination Fire & Smoke Dampers are approved for use in static or dynamic

More information

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

SUBMITTAL INDEX. Product Datasheets: Product Approvals: Product Datasheets: SUBMITTAL INDEX HF Corrugated Deck Cast In Place Sleeve Non Met HF Corrugated Deck Optional Pipe Sleeve Non Met HF Corrugated Deck Seal Sleeve Non Met HF Optional Pipe Size Sleeve Non

More information

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIPS Installation Manual Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86

More information

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS BuildingName The Description of the Project P00000000 0000 DOCUMENTS Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General

More information

FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT

FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT Vice President Engineering and Research Brick Industry Association Reston, VA United States of America JOHN SWINK Regional Engineer

More information

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008 XHBN.FF-D-3008 - Page 1 of 2 XHBN.FF-D-3008 Page Bottom See General Information for System No. FF-D-3008 March 20, 2006 Assembly Rating 2 Hr Nominal Joint Widths 14, 16, 18 and 20 In. (See Item 2A) Class

More information

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316 International Beams Inc. 2010 Boul. St-Elzear Quest Laval, QC H7L 3N4 CANADA This report is for the exclusive use of Intertek

More information

Gypsum Board Systems Manual

Gypsum Board Systems Manual CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Waterproof Contractor Submittal (Joint Strip) Manufacturer's Representative: Rectorseal

More information

THERMAL AND MOISTURE PROTECTION

THERMAL AND MOISTURE PROTECTION RELATED DOCUMENTS: The general provisions of the Contract, including General and Supplementary Conditions, and General Requirements, and Division 1 specifications that apply to the work specified in this

More information

Monolithic Isolation Fittings

Monolithic Isolation Fittings Monolithic Isolation Fittings The Industry s Dual O Ring Seal Standard Tests Include: 100% Hydrostatic Pressure & Electrical Tests 100% Ultrasonic of Welds 100% Magnetic Particle of Welds 100% Dye Penetrant

More information

SECTION STRUCTURAL INSULATED PANELS

SECTION STRUCTURAL INSULATED PANELS SECTION 06120 STRUCTURAL INSULATED PANELS Copyright 2011-2012 Korwall Industries, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural Insulated Roof Panels. B. Structural Insulated

More information

SECTION FIRESTOPPING

SECTION FIRESTOPPING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 84 00 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

SECTION WALL AND DOOR PROTECTION

SECTION WALL AND DOOR PROTECTION PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 26 00 WALL AND DOOR PROTECTION SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable to

More information

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD. Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD. Included are selected sections of codes taken directly from: 1997 Uniform

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3462 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell BROADCAST: M16-001 BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell TITLE: DESCRIPTION: NEW PRODUCT LAUNCH 3M FIRE BARRIER BLOCKS, PLUGS AND PLANKS 3M

More information

Session: Firestop - Let s Walk a Project and Look at Firestop Together

Session: Firestop - Let s Walk a Project and Look at Firestop Together Session: Firestop - Let s Walk a Project and Look at Firestop Together Firestop: Let s walk a project and look at firestop together Richmond ICC Sharron Halpert HLS Consulting Education, Consultation and

More information

Protecting Penetrations in Fire Rated Construction

Protecting Penetrations in Fire Rated Construction Protecting Penetrations in Fire Rated Construction NY State Fire Marshals and Inspectors Conference September 7 th Bruce E. Johnson UL Codes and Advisory Services UL and the UL logo are Trademarks of UL

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES 1.0 INTRODUCTION INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR COMPOSITE STEEL SHEET AND NONCOMBUSTIBLE SHEATHING PANELS EC 012-2016

More information

Joint Systems. System No. FF-D-0044

Joint Systems. System No. FF-D-0044 XHBN.FF-D-0044 System No. FF-D-0044 November 05, 2003 Assembly Rating 2 Hr Nom Joint Width 1 in. Class II and III Movement Capabilities 50% Compression or Extension 1. Floor or Wall Assembly Reinforced

More information

Fire Protection Products

Fire Protection Products Fire Protection Products Product Data Sheet July 2017 Product Description Product Features Applications Specifications is a sprayable, moisture-curing, hybrid siliconized polymer that forms a tough, elastomeric

More information

System No. HW-D-0548

System No. HW-D-0548 System No. Ì73hwdÇ%P+11bÎ ANSI/UL2079 Assembly atings - 1 and 2 Hr (See Item 2) Maximum Joint Width - 3/4, 1 or 1-1/2 In. (See Item 3) Class II Movement Capabilities - 50 or 100 %Compression or Extension

More information

Firestopping Submittal Package

Firestopping Submittal Package Firestopping Submittal Package Project: Architect: General Contractor: Installation Contractor: Distributor (and Contact): Commercial Plumbing - Steel Pipes Manufacturer's Representative: Rectorseal -

More information

Ultralane 781A/B. Product Datasheet. Polyurethane Encapsulation System

Ultralane 781A/B. Product Datasheet. Polyurethane Encapsulation System Product Datasheet Ultralane 781A/B Polyurethane Encapsulation System Ultralane 781A/B is a room temperature curing polyurethane system, formulated for potting and encapsulating electrical and electronic

More information

Triton BK Backer Board & Tile Underlayment

Triton BK Backer Board & Tile Underlayment 1 Backer Board & Tile Underlayment Lightest Cementitious Backer Board High strength cement technology Free of Crystalline Silica, VOCs, and harsh chemicals Easy to score and snap, fasten, and install Description

More information