We solved the science of safely insulating air ducts.

Size: px
Start display at page:

Download "We solved the science of safely insulating air ducts."

Transcription

1 We solved the science of safely insulating air ducts. Patented duct liners eliminate fibers, stop mold, reduce noise while they insulate. Armaflex : The IAQ Insulation

2 AP Armaflex SA Black Duct Liner Mold resistant. Fiber free. Quieter. The IAQ Insulation TM for air ducts Made with Microban antimicrobial protection: EPA Registered for ductwork, including hospitals Reduces HVAC noise FM APPROVED FOR GREENER BUILDINGS Duct Liner

3 Duct Liner AP Armaflex SA Black Duct Liner is a patented* non-fibrous duct liner with an advanced, pressure sensitive adhesive system for non-pinned field applications. Mold resistant: Made with Microban antimicrobial product protection. Indoor Air Quality: Fiber-free, formaldehyde-free, low VOCs, non-particulating Smooth surface: Reduces dirt, wipes clean Plenum rated: Safe for institutional air ducts, meets NFPA standards Noise blocking and vibration dampening Description AP Armaflex SA Duct Liner / Wrap is a black, flexible elastomeric thermal insulation. Its closed-cell structure prevents condensation and moisture wicking, and makes it an efficient insulation. It is manufactured without the use of CFCs, HFCs or HCFCs. The Microban antimicrobial protection is registered by the Environmental Protection Agency for use in air ducts (EPA Reg. No ). It is added during manufacturing to provide an extra level of defense in the natural mold resistance of AP Armaflex. AP Armaflex SA Duct Liner is also effective for reducing HVAC noise. It is supplied in 36 x 48 sheets and in rolls 48 and 60 wide, in thicknesses up to 1. Uses and Applications AP Armaflex SA Black Duct Liner / Wrap is ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control, resistance to moisture, damage or heat gain; or HVAC noise blocking or sound dampening. Application areas include schools, hospitals, hotels, commercial and public buildings. Installation Note: Must be installed according to Installation of Armaflex Insulations publication ( ). When air stream velocities exceed 4,000 FPM (20.3m/second), metal nosing should be applied to every leading edge. Nosing may be formed on ducts or be channeled or zee-attached by screws, rivets or welds. ALCOHOL The temperature of the air and of the insulation should be between 40 F (4 C) and 100 F (38 C) at the time of installation. Prepare surface by cleaning with appropriate cleaner. Measure. Approvals and Compliance Product approved through continuing supervision by Factory Mutual Approvals to provide consistent actual values for thermal conductivity, water vapor transmission and fire rating. AP Armaflex SA Black Duct Liner / Wrap also meets requirements of NFPA 90A and 90B for Duct Coverings and Linings, and UL 181 for Mold Growth. Approved for use in return air plenums, conforms to ASTM C 1534 requirements and withstands temperatures of 250. All AP Armaflex insulation meets requirements of International Energy Conservation Code (IECC) and ASHRAE for R-Value 4.2 at 1 thickness. Cut with sharp knife. Peel back enough release liner to start. Square off sheet along an edge or corner. Press the sheet to the surface taking care not to trap any air. ALL ARMACELL FACILITIES IN NORTH AMERICA ARE ISO 9001:2000 CERTIFIED. Reach behind the Armaflex sheet and peel liner back while pressing the sheet to the surface. Press firmly. Butt joints require the use of compression joints to prevent the possible opening of seams. Duct Liner For the latest document, please refer to our website.

4 AP/Armaflex SA Black Duct Liner / Wrap Patented* for Air Systems that Require an Alternative Duct Liner / Wrap Features Advanced, aggressive PSA Closed cell structure Made with Microban antimicrobial product protection Smooth surface that reduces dirt and debris accumulation Elastomeric material Inherent vapor retarder Benefits No pinning required, faster installation Resists moisture, nonwicking Reduced water presence in system and insulation Noise blocking Nondusting Longer life Won t contribute to air quality problems Resists mold on the insulation EPA registered for use in air duct insulation Inhibits amplification of biological contaminants Basis for continuing system hygiene Fiber free Resistant to incidental damage No special tools; no dust mask required during fabrication and installation Requires no mastics Competitive total installed cost * US Patent Thermal Duct Lining Insulation for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning. Physical Properties Specifications Values Test Method Thermal Conductivity, Btu in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) 0.25 (0.036) (0.037) ASTM C 177 or C 518 Water Vapor Permeability, Perm-inch. [Kg/(s m Pa)] 0.05 [0.725 x ] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index ➀ Through 1 (25 mm) 25/50 Mold Growth Fungi Resistance Bacterial Resistance UL181 ASTM G21/C1338 ASTM G22 ASTM E 84 CAN ULC S-102 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➁ Lower Use Limit ➂ Erosion Resistance 180 F (82 C) -297 F (-183 C) Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071 Corrosiveness Noncorrosive ASTM C 665 Odor Emissions No objectionable odors ASTM C 665 Density, Typical Range ➃ lbs/ft Sound Absorption Coefficients at Frequency ASTM D 1622 ASTM D 1667 Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC Nom. 1 (25mm) Notes ➀ AP/Armaflex SA Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1 (25 mm) when tested according to ASTM E 84 and CAN ULC S-102. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. ➁ Withstands temperature of 250 F (121 C) when tested according to ASTM C 411. Test Method for Surface Performance of High- Temperature Insulations. At this temperature, AP/Armaflex SA Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180 F (82 C). ➂ At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. ➃ Reference Only Performance approved through continuing supervision by Factory Mutual Approval. Sound Transmission Class (STC) Sizes Thickness STC Class Sheet Width / Length 36 x 48 Nom. 1/2 (13 mm) 25 Nom. 1 (25mm) 25 Roll Width Wall Thickness 48 (all thicknesses) and 60 (1 only) 3/8, 1/2, 3/4 and 1 Duct Liner For the latest document, please refer to our website.

5 ARMACELL LLC TEL: FAX: info.us@armacell.com 7600 Oakwood Street Extension Mebane, NC Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice. MICROBAN is a registered trademark of Microban Products Company. 021B NA NA 2008 Armacell LLC Printed in United States of America

6 AP Coilflex TM Conformable Duct Liner Patent Pending! For factory application. Fiber free, mold resistant. Soft elastomeric foam easily conforms to fabricated corners Engineered for sheet metal shops Cost-effective alternative, half the hand labor (cutting) Fiber free and noise reducing Water-based adhesives compatible Duct Liner

7 Duct Liner Patent pending AP Coilflex Duct Liner is engineered for automated applications with water-based adhesives in accordance with SMACNA pinning and spacing guidelines, or unpinned applications using an Armaflex 520 Adhesive. Available in rolls in a range of widths including 59 and 60, in 1 thickness (or 1/2 special order). Practical: Easily conforms to fabricated duct corners without stiffness or compression; cuts easier and faster Mold Resistant: Made with Microban antimicrobial product protection Indoor Air Quality: Fiber-free, formaldehyde-free, low VOC s, non-particulating Plenum rated: Safe for institutional air ducts, meets NFPA standards Noise blocking and vibration dampening Description AP Coilflex Duct Liner is a patent pending, highly conformable, pliable elastomeric thermal insulation. It is manufactured without the use of CFCs, HFCs or HCFCs. The Microban antimicrobial protection is registered by the Environmental Protection Agency for use in air ducts (EPA Reg. No ). It is added during manufacturing to provide an extra level of defense to the natural mold resistance of AP Coilflex. AP Coilflex is effective for reducing HVAC noise. It is supplied in rolls 46, 47, 48, 56-1/4, 59 and 60 wide, in 1 (or 1/2 special order) thicknesses. It can be applied with current water-based adhesives and pinning per SMACNA requirements or unpinned using Armaflex 520 Adhesives. Approvals and Compliance AP Coilflex Duct Liner meets requirements of NFPA 90A and 90B for Duct Coverings and Linings, and UL 181 for Mold Growth. Approved for use in air plenums, conforms to ASTM C 1534 requirements and withstands temperatures of 250 F. Like all AP Armaflex insulation, AP Coilflex meets requirements of International Energy Conservation Code (IECC) and ASHRAE for R-Value 4.2 at 1 thickness. Uses and Applications AP Coilflex Duct Liner, like AP Armaflex Duct Liners, is ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control and resistance to moisture, damage or heat gain. They also reduce noise generated by fans and air movement as well as the rattle or popping of sheet metal air ducts. Coilflex is especially effective factory-applied, including on automated coiling lines, for end use in areas like schools, hospitals, hotels, commercial and public buildings. Installation AP Coilflex can be applied with current water-based adhesives. Secure with metal fasteners in accordance with SMACNA publication, HVAC Duct Construction Standards, Metal and Flexible. If installed using Armaflex 520 Adhesive, no pinning is required. When air stream velocities exceed 4,000 FPM (20.3m/second), metal nosing should be applied to every leading edge. Nosing may be formed on ducts or be channeled or zee-attached by screws, rivets or welds. Due to its exceptional conformability, the insulation is bendable together with the sheet metal on automated coil lines. The structure of Coilflex helps prevent compression. ALL ARMACELL FACILITIES IN NORTH AMERICA ARE ISO 9001:2000 CERTIFIED. Features Conformable nonfibrous structure Made with Microban antimicrobial product protection Noise reducing, higher-density material Smooth surface that reduces dirt and debris accumulation Elastomeric foam Inherent vapor retarder Benefits Nondusting Longer life Won t contribute to air quality problems Resists mold on the insulation EPA registered for use in air duct insulation More productive work environment Reduces or blocks HVAC noise Helps prevent metal duct vibration, sound transfer Inhibits amplification of biological contaminants Basis for continuing system hygiene Fiber free Resistant to incidental damage No special tools; no dust mask required during fabrication and installation, no itch Requires no mastics Competitive total installed cost Duct Liner For the latest document, please refer to our website.

8 Physical Properties* Specifications Values Test Method Thermal Conductivity, Btu in./h ft 2 F (W/mK) 75 F mean temperature (24 C) 90 F mean temperature (32 C) 0.25 (0.036) (0.037) ASTM C 177 or C 518 Flame Spread and Smoke Developed Index ➀ Through 1 (25 mm) 25/50 ASTM E 84 Mold Growth Fungi Resistance Bacterial Resistance Upper Use Limit ➁ Lower Use Limit ➂ Erosion Resistance UL181 ASTM G21/C1338 ASTM G F (82 C) -297 F (-183 C) Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071 Corrosiveness Noncorrosive ASTM C 665 Odor Emissions No objectionable odors ASTM C 665 Density, Typical Range ➃ lbs/ft Sound Absorption Coefficients at Frequency ASTM D 1622 ASTM D 1667 Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC Nom. 1 (25mm) Notes ➀ AP Coilflex Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1 (25 mm) when tested according to ASTM E 84. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. ➁ Withstands temperature of 250 F (121 C) when tested according to ASTM C 411. Test Method for Surface Performance of High- Temperature Insulations. At this temperature, AP Coilflex Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180 F (82 C). ➂ At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency of Coilflex insulation. ➃ Reference Only * AP Coilflex is a patent pending product Sound Transmission Class (STC) Thickness STC Class Nom. 1/2 (13 mm) 25 Nom. 1 (25mm) 25 Sizes Roll Width 46, 47, 48, 56-1/4, 59 and 60 Wall Thickness 1 and 1/2 (special order) Duct Liner For the latest document, please refer to our website.

9 ARMACELL LLC TEL: FAX: info.us@armacell.com Oakwood Street Extension Mebane, NC Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice. MICROBAN is a registered trademark of Microban Products Company NA NA 2009 Armacell LLC Printed in United States of America

10 AP/Armaflex Tube Insulation Super Moisture Control, Mold-Resistant Closed-cell, nonwicking Microban antimicrobial product protection The IAQ Insulation Fiber-free FOR GREENER BUILDINGS FM APPROVED Tube Insulation

11 AP Armaflex Pipe (Tube) Insulation AP Armaflex Pipe (Tube) Insulation is the original closed cell, fiber-free elastomeric foam and the world s most recognized brand in flexible mechanical insulation. Proven: World s first choice for insulating chilled water and refrigeration lines Mold resistant: Made with Microban antimicrobial product protection Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOCs, nonparticulating Durable: No fragile vapor retarder Description AP Armafex Pipe (Tube) Insulation is a black flexible elastomeric thermal insulation. The expanded closed-cell structure makes it an efficient insulation. It is manufactured without the use of CFC s, HFC s or HCFC s. All AP Armaflex products are made with Microban antimicrobial product protection for added defense against mold on the insulation. Nominal wall thicknesses of 3/8, 1/2, 3/4, 1 and 1-1/2 (10, 13, 19, 25 and 38mm) Popular sizes up to 6 IPS Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals to consistently provide actual values on these key performance criteria for mechanical system insulation: Thermal Conductivity: 0.25 BTU-in/hr. ft 2 F Water Vapor Transmission: 0.05 perm-inch Fire Rating: will not contribute significantly to fire (simulated end-use testing) As tested by ASTM E 84 Method of Test for Surface Burning Characteristics for Building Materials and CAN/ULC S-102, AP Armaflex Pipe Insulation in wall thicknesses through 1-1/2 (38mm) has a flame-spread index of less than 25 and a smokedeveloped index of less than 50. Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Efficiently reduces heat flow for hot-water plumbing, liquid-heating and dualtemperature piping Acceptable in wall thicknesses through 1-1/2 (38mm) for use in air plenums and conforms to NFPA 90A and NFPA 90B requirements The recommended temperature usage range for AP Armaflex Pipe Insulation is -297 F to +220 F (-183 C to +105 C). For use on cold pipes, thicknesses have been calculated to control condensation on the insulation outer surface, as shown in the table of thickness recommendations. AP Armaflex meets the energy code requirements of ASHRAE 90.1, ASHRAE 90.2 International Energy Conservation Code (IECC) and other building codes. Application AP Armaflex Pipe Insulation in unslit tubular form can be slipped onto piping before it is connected, or it can be slit lengthwise and snapped over piping already connected. Fitting covers are fabricated from miter-cut tubular form. In all cases, butt joints and seams are to be sealed with one of our Armaflex adhesives: Armaflex 520, 520 Black or, where a low V.O.C. adhesive is required, 520 BLV. 520 Adhesives are contact adhesives; therefore, in all cases, both surfaces to be joined are coated with adhesive. For pipes greater than 6 IPS, use AP/Armaflex Sheet/Roll insulation. For thicknesses greater than 1, sleeve the insulation. See technical bulletin #030 for additional information. AP/Armaflex pipe insulation is available in 1-1/2 wall thicknesses with 25/50 rating for ID size range from 7/8 to 4 IPS. AP Armaflex normally requires no supplemental vapor-retarder protection but additional vapor-retarder protection may be necessary when installed on very-low-temperature piping or exposure to continually high humidity conditions. AP Armaflex is designed for installation above or below ground. For below ground applications, contact Armacell or see our Technical Bulletin No. 7 on our website, www. armacell.com. Outdoors, a weather-resistant protective finish is to be applied and Armaflex WB Finish is recommended. Armaflex insulation products must be installed according to Installation of Armaflex Insulations brochure. Proper installation is required to assure Armaflex insulation performance. Specification Compliance ALL ARMACELL FACILITIES IN NORTH AMERICA ARE ISO 9001:2000 CERTIFIED. AP Armaflex Tube Insulation For the latest document, please refer to our website. AP Armaflex Pipe Insulation developed to meet: ASTM C 534, Type I Tubular Grade 1 ASTM E 84, NFPA 255, UL 723 CAN/ULC S102 UL 94 5V-5A, V-O, File E NFPA 90A, 90B UL 181 ASTM G-21/C1338, ASTM G-22 ASTM D 1056, 2B1 MIL-P-15280J, FORM T MIL-C-3133C (MIL STD 670B), Grade SBE 3 MEA M City of LA RR 7642

12 Physical Properties Specifications Values Test Method Thermal Conductivity, Btu in./h ft 2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) 0.25 (0.036) (0.037) ASTM C 177 or C 518 Water Vapor Permeability, Perm-in. [Kg/(s m Pa)] 0.05 (0.725 x ) ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1-1/2 (38mm) 25/50 Mold Growth Fungi Resistance Bacterial Resistance UL181 ASTM G21/C1338 ASTM G22 ASTM E 84 CAN/ULC S102 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit F (105 C) Lower Use Limit F (-183 C)* Ozone Resistance good Sizes Wall Thickness, (nominal) Form Inside Diameter, Tubular Form Length of Sections, Feet, Tubular Form 3/8, 1/2, 3/4, 1, 1-1/2 (10, 13, 19, 25 and 38mm) 3/8 ID to 6 IPS (10mm ID to 168mm) [1-1/2 wall: 7/8 to 4 IPS (22mm to 114mm)] 6 (1.8m) [1-1/2 wall: 3 (0.9m)] Density, Typical Range lbs./ft. 3 ASTM D 1622 or D 1667 Notes 1 On the heating cycle, AP Armaflex Pipe Insulation will withstand temperatures as high as 220 F (105 C). 520, 520 Black or 520 BLV Adhesive may be used with pipe insulation applications up to 220 F (105 C). 2 At temperatures below -20 F (-29 C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation. 3 Reference only. * For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell. Performance approved through continuing supervision by Factory Mutual Approvals. Armaflex Pipe Insulation Thickness Recommendations For Controlling Outer Insulation Surface Condensation (Based upon available manufactured thicknesses and not intended to supercede any state or local building codes.) Pipe Size BASED ON NORMAL DESIGN CONDITIONS* 3/8 ID through 1-1/8 ID (10mm 28mm) Over 1-1/8 ID through 2-1/8 ID (28mm 54mm) Over 2-1/8 ID through 2-5/8 ID (54mm 67mm) Over 2-5/8 ID through 6 IPS (67mm 168mm) BASED ON MILD DESIGN CONDITIONS** 3/8 ID through 2-5/8 ID (10mm 67mm) Over 2-5/8 ID through 6 IPS (67mm 168mm) BASED ON SEVERE DESIGN CONDITIONS* 3/8 ID through 1-5/8 ID (10mm 42mm) Over 1-5/8 ID through 3-5/8 ID (42mm 92mm) Over 3-5/8 ID through 6 IPS (92mm 168mm) For VERY SEVERE DESIGN CONDITIONS which Armacell would consider temperatures above 90 F(32 C) and/or above 80% RH Line Temperatures 50 F (10 C) 35 F (2 C) 0 F ( 18 C) 20 F ( 29 C) Nom 3/8 (10mm) Nom 3/8 (10mm) Nom 3/8 (10mm) Nom 1/2 (13mm) Nom 3/8 (10mm) Nom 1/2 (13mm) Nom 3/4 (19mm) Nom 3/4 (19mm) Nom 3/4 (19mm) Nom 1/2 (13mm) Nom 1/2 (13mm) Nom 1/2 (13mm) Nom 3/4 (19mm) Nom 3/8 (10mm) Nom 1/2 (13mm) Nom 1 (25mm) Nom 1 (25mm) Nom 1 (25mm) Nom 3/4 (19mm) Nom 1 (25mm) Nom 1 (25mm) Nom 1 (25mm) Nom 1/2 (13mm) Nom 1/2 (13mm) Nom 1-1/2 (38mm) Nom 1-1/2 (38mm) Nom 1-1/2 (38mm) Consult Armacell for recommended insulation thickness Nom 1 (25mm) Nom 1 (25mm) Nom 1-1/4 (32mm) Nom 1-1/4 (32mm) Nom 3/4 (19mm) Nom 3/4 (19mm) Nom 1-1/2 (38mm) Nom 1-3/4 (44mm) Nom 2 (50mm) NOTE: Thicknesses greater than 1 (25mm) are multiple-layer applications, see technical bulletin #30. *BASED ON NORMAL DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface condensation indoors under normal design conditions, a maximum severity of 85 F (29 C) and 70% RH. Armacell research and field experience indicate that indoor conditions anywhere in the United States seldom exceed this degree of severity. **BASED ON MILD DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface condensation indoors under mild design conditions, a maximum severity of 80 F (27 C) and 50% RH. Typical of these conditions are most air-conditioned spaces and arid climates. ***BASED ON SEVERE DESIGN CONDITIONS AP Armaflex in the thicknesses noted and within the specified temperature ranges will control outer insulation surface condensation indoors under severe design conditions, a maximum severity of 90 F (32 C) and 80% RH. Typical of these conditions are indoor areas in which excessive moisture is introduced or in poorly ventilated confined areas where the temperature may be depressed below ambient. AP Armaflex Tube Insulation For the latest document, please refer to our website.

13 Air-drying contact adhesives that are excellent for joining seams. Armaflex 520, 520 Black & 520 BLV Adhesive ARMACELL LLC TEL: FAX: info.us@armacell.com 7600 Oakwood Street Extension Mebane, NC Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice. Microban is a registered trademark of Microban Products Company NA NA 2009 Armacell LLC Printed in United States of America

14 ArmaTuff PLUS II Laminated Sheets & Rolls New & Improved ArmaTuff! Less wrinkling, tougher than ever. Available in White and Silver Armaflex with heavy-duty 16 mil laminate No painting required 10-year membrane warranty Puncture-resistant, smooth surface Durable, maintenance-free FOR GREENER BUILDINGS Armacell: The Energy Savers Laminated Sheets & Rolls

15 ArmaTuff PLUS II Laminated Sheets & Rolls ArmaTuff PLUS II is the premiere Armacell Coating System for outdoor applications. It provides a tough-as-metal surface on Armaflex insulation for superior protection against ultraviolet radiation and punctures. Maintenance-free: UV- and damage resistant 16 mil laminate Resists wrinkling: Special multi-layer laminate maintains smooth surface Long-lasting protection: 10-year membrane limited warranty Flexible application: Available with or without PSA Colors: White or Siver (on a make-to-order basis) Installation Applying Non-Self Adhering ArmaTuff Plus II Description ArmaTuff PLUS II is Armaflex insulation with a 16 mil laminated covering membrane (a UV protective white or silver, blended polymeric top surface and a puncture-resistant blended polymeric base, around a scrim reinforced core). The membrane has a 10-year limited warranty against breakdown due to UV radiation. Armaflex is a mold-resistant flexible elastomeric thermal insulation. Its closed-cell structure prevents condensation and moisture wicking, and makes it an efficient insulation. It is manufactured without the use of CFCs, HFCs or HCFCs. It is available in 36 x 48 sheets (with or without pressure sensitive adhesive) and in rolls 48 wide (without PSA), in thicknesses up to 2. Uses and Applications ArmaTuff PLUS II is designed to be used for all exterior applications: Exterior ducts, tanks, vessels, large pipes and fittings. The laminate is resistant to UV, ozone, acid rain and most industrial pollutants. No painting is required. Application ArmaTuff Plus II is installed using Armaflex Adhesives or with pre-applied pressure sensitive adhesive (PSA) for application to large, flat or curved metal surfaces such as ducts, vessels, very large pipes or tanks. The seams must be installed in compression and sealed with Armaflex Adhesives. Cover the seam with ArmaTuff Plus II Seal Tape. Armaflex 520 Adhesive is a contact adhesive: therefore it must be applied to both surfaces, allowed to get tacky, and the surfaces joined with pressure. Exterior duct work must be pitched to allow rain water to run off the insulation. ArmaTuff Plus II is designed for installation in above ground applications. Armaflex insulation products must be installed according to Installation of Armaflex Insulations brochure. Proper installation is required to assure Armaflex insulation performance. The application temperature should be above 40 F (+4 C) and 100 F (+38 C). 1. Always prepare surface by cleaning with denatured alcohol. 3. Roll thin coat of 520 Adhesive to insulation. 5. Apply ArmaTuff Plus II to top surface, overlapping the side pieces. 2. Insulate sides first. Apply thin, uniform coat of Armaflex 520 Adhesive. 4. Position carefully and apply ArmaTuff Plus II (White or Siver). Contact adhesive bonds instantly. 6. Seal and protect exposed edges and seams with ArmaTuff Plus II Seal Tape (White or Silver). ALL ARMACELL FACILITIES IN NORTH AMERICA ARE ISO 9001:2000 CERTIFIED. ArmaTuff PLUS II Laminated Sheets & Rolls For the latest document, please refer to our website.

16 Physical Properties Specifications Values Test Method Thermal Conductivity, Btu in./h ft 2 F (W/mK) 75 F Mean Temperature (24 C) 90 F Mean Temperature (32 C) Water Vapor Permeability, Perm-in. [Kg/(s m Pa)] Mold Growth Fungi Resistance Bacterial Resistance 0.25 (0.036) (0.037) ASTM C 177 or C 518 Laminate 0.00 Foam 0.05 UL181 ASTM G21/C1338 ASTM G22 ASTM E 96, Procedure A Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit 180 F (82 C) Lower Use Limit F (-183 C)* UltraViolet (UV) Resistance Excellent Chemical Resistance Excellent ASTM G 90 QUV Chamber Weatherability Excellent ASTM D471 Durability Excellent Density, Typical Range lbs./ft. 3 ASTM D 1622 or D 1667 Sizes Sheet With or Without Adhesive Width and Length Thickness (nominal) Sizes Roll Without Adhesive Width Thickness (nominal) x Length 36 x 48 (0.915 m x 1.22 m) 1/2, 3/4, 1, 1-1/2 and 2 (13, 19, 25, 38 and 50 mm) 48 (1.22 m) 1/2 x 70 (13 mm x 30.5 m) 3/4 x 50 (19 mm x 21.4 m) 1 x 35 (25 mm x 10.7 m) 1-1/2 x 25 (38 mm x 7.6 m) 2 x 18 (50 mm x 5.4 m) Notes 2 At temperatures below -20 F (-29 C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of ArmaTuff Plus II. 3 Reference only. * For applications of -40 F to -297 F (-40 C to -183 C), contact Armacell. Finishing the Installation with ArmaTuff Plus II Seal Tape ArmaTuff Plus II (White or Silver) is a complete insulation system providing durable, UV-resistant and maintenance-free outdoor performance. Tape is backed with pressure sensitive adhesive and designed to provide protection along the seams and exposed edges of the insulation. Tape is supplied in rolls 4 or 6 -wide for sealing seams and exposed edges of ArmaTuff Plus II. It is also available 23 wide as qa pipe covering Apply ArmaTuff Plus II Seal Tape along all exposed edges of ArmaTuff Plus II installations. Finish by applying even pressure, using a roller. Use the ArmaTuff Plus II Seal Tape for weather-tight seam protection. Use roller to finish. ArmaTuff PLUS II Laminated Sheets & Rolls For the latest document, please refer to our website.

17 Air-drying contact adhesives that are excellent for joining seams. Armaflex 520, 520 Black & 520 BLV Adhesive ARMACELL LLC TEL: FAX: info.us@armacell.com 7600 Oakwood Street Extension Mebane, NC Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, relying upon the other source(s) to provide accurate information. Information provided as a result of Armacell s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice. Microban is a registered trademark of Microban Products Company. 018P NA NA 2009 Armacell LLC Printed in United States of America

Tube Insulation. Fiber Free

Tube Insulation. Fiber Free Fiber Free Tube Insulation Fiber-free, flexible, elastomeric pipe insulation for reliable protection against condensation, mold, energy loss and ultraviolet radiation in residential and commercial applications

More information

Armacell Product Selection Guide

Armacell Product Selection Guide Armacell Product Selection Guide Guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex The IAQ Insulation Exclusive EPA-registered antimicrobial Supports LEED

More information

PRODUCT SELECTION GUIDE

PRODUCT SELECTION GUIDE Fiber Free PRODUCT SELECTION GUIDE Quick guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex GREENGUARD Certified products are certified to GREENGUARD standards

More information

We solved the science of safely insulating air ducts.

We solved the science of safely insulating air ducts. We solved the science of safely insulating air ducts. Patented duct liners eliminate fibers, stop mold, reduce noise while they insulate. Armaflex : The IAQ Insulation Now you can safely insulate & quiet

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

TOTALINE COPPER TUBING

TOTALINE COPPER TUBING TOTALINE COPPER TUBING TOTALINE COPPER TUBE AIR CONDITIONING & REFRIGERATION P744 WEIGHT PER TUBE 3/8.030 2.30 ACR-20 x 3/8 1/2.035 3.70 ACR-20 x 1/2 5/8.040 5.30 ACR-20 x 5/8 3/4.042 6.70 ACR-20 x 3/4

More information

Plumbing Pipe Insulation Specification Submitted by: Armacell LLC. Plumbing Pipe Insulation Specification Armacell LLC 1

Plumbing Pipe Insulation Specification Submitted by: Armacell LLC. Plumbing Pipe Insulation Specification Armacell LLC 1 Plumbing Pipe Insulation Specification 2005 Armacell LLC 1 Part 1 General 1.01 Scope of Work: A. Provide piping insulation as specified below. The purpose of the thermal pipe insulation is for condensation

More information

Master Insulation Guide Specification for Mechanical Systems

Master Insulation Guide Specification for Mechanical Systems for Mechanical Systems AP Armaflex Pipe Insulation AP Armaflex W Pipe Insulation AP Armaflex SS Pipe Insulation AP Armaflex Sheet and Roll Insulation AP Armaflex SA Sheet and Roll Insulation ArmaTuff Laminated

More information

The Right Insulation for Indoor Air Quality

The Right Insulation for Indoor Air Quality AP Armaflex The Closed Cell Solution The Right Insulation for Indoor Air Quality ADDED PROTECTION FOR COLD SYSTEMS AND AIR HANDLING SYSTEMS Prevents moisture intrusion Inhibits mold and mildew Fiber free,

More information

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

GUIDE SPECIFICATION: MECHANICAL SYSTEMS GUIDE SPECIFICATION: MECHANICAL SYSTEMS This specification guide includes thermal & acoustical insulation for piping, equipment, vessels, and air handling systems. This section is based on the format recommended

More information

The Right Insulation for Cold Systems

The Right Insulation for Cold Systems AP Armaflex The Closed Cell Solution The Right Insulation for Cold Systems PREVENTS MOISTURE INTRUSION AND ITS CONSEQUENCES Ensures long-term thermal performance Inhibits mold and mildew, protects IAQ

More information

K-FLEX DUCT LINER GRAY

K-FLEX DUCT LINER GRAY K-FLEX DUCT LINER GRAY Flexible, Closed Cell Elastomeric Foam Insulation Responsive to Market Industry & Product Expertise 3rd Party Certified Products 25/50-rated up to 2 thick Systems Approach Factory-applied

More information

K-FLEX USA MECHANICAL INSULATION CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE

K-FLEX USA MECHANICAL INSULATION CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE CONTENTS: SPECIFICATION GUIDE PRODUCT SELECTION GUIDE LEED CONTRIBUTION GUIDE SPECIFICATION GUIDE This specification guide includes thermal & acoustical insulation for piping, equipment and vessels, and

More information

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS Friendly Feel Duct Wrap with KwikStretch Markings Knauf Data Sheet AH-DS-5 05-07 For cooling, heating or dual temperature service. Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD

More information

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips.

EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips. EXPERIENCE COUNTS! Specializing in more than just products we put the competitive advantage at your fingertips. Armaflex is a flexible, closed cell, elastomeric, nitrile rubber, insulation. It is a highly

More information

Standard and Mini Split Line Sets

Standard and Mini Split Line Sets For HVACR Applications Job Name Job Location Engineer Contractor Wholesaler Linesets, Inc. Rep Product Description: Linesets, Inc. Standard and Mini Split Line Sets are available in either an elastomeric,

More information

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology

Knauf Data Sheet AH-DS-5E Friendly Feel. Duct Wrap. with ECOSE Technology Knauf Data Sheet AH-DS-5E 07-09 Friendly Feel with ECOSE Technology Duct Wrap For cooling, heating or dual temperature service. Friendly Feel Duct Wrap meets the most stringent IAQ tests GREENGUARD Children

More information

ARIFLEX. Rubber Insulation Foam Tube & Foam Sheet

ARIFLEX. Rubber Insulation Foam Tube & Foam Sheet ARIFLEX Rubber Insulation Foam Tube & Foam Sheet General Amiantit Group of Companies The Amiantit Group is a leading industrial organization that was established in Dammam, Saudi Arabia in year 1968. Today,

More information

EFRIGERATION INSTALLATION GUIDE

EFRIGERATION INSTALLATION GUIDE R EFRIGERATION INSTALLATION GUIDE Golden Rules for Working with INSTALLATION Armaflex and good adhesive brushes1 fittings. mitered fabricated Use good quality tools and, in particular, fresh 520, 520 Black

More information

Aluminum Lagging Roll Jacketing Fittings

Aluminum Lagging Roll Jacketing Fittings Product Catalog Aluminum Lagging DESCRIPTION ITW Pabco/Childers Aluminum Jacketing is the premier protective outer surface for mechanical insulation systems including pipe, vessels, and equipment. It protects

More information

Insulation engineered to prevent condensation and energy loss

Insulation engineered to prevent condensation and energy loss Insulation engineered to prevent condensation and energy loss Triple security: effective condensation control, FM Approved and excellent fire performance Highly energy efficient to give long-term energy-saving

More information

Chilled Water. Product performance for insulation of chilled water piping

Chilled Water. Product performance for insulation of chilled water piping Chilled Water Product performance for insulation of chilled water piping ABOUT K-FLEX USA K-FLEX USA IS A LEADING MANUFACTURER of flexible, closed cell elastomeric insulation for mechanical piping, air

More information

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method

More information

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) PART 1 GENERAL 1.01 DESCRIPTION A. Insulate the following: 1. Piping: a. Heating water b. Chilled water c. Condenser water (outdoors with heat

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket. SECTION 230719 - HVAC PIPING INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Piping insulation. B. Jackets and accessories. 1.2 RELATED REQUIREMENTS A. Section 07813 - Fire Procection, HVAC & Plumbing

More information

FIRE STATION 55 June 14, 2010

FIRE STATION 55 June 14, 2010 SECTION 15250 MECHANICAL INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work Includes 1. Insulation of Domestic Water Piping. 2. Pipe Insulation of refrigerant piping. 3. Insulation of ductwork. 4. Aluminum

More information

SECTION DUCT INSULATION

SECTION DUCT INSULATION SECTION 23 07 13 - DUCT INSULATION PART I - GENERAL 1.1 SECTION INCLUDES A. Ductwork Insulation B. Fan and Equipment Insulation C. Insulation Jackets D. Insulation Lagging 1.2 RELATED SECTIONS A. Section

More information

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Knauf Data Sheet AH-DS-12e Sonic XP Duct Liner. with ECOSE Technology

Knauf Data Sheet AH-DS-12e Sonic XP Duct Liner. with ECOSE Technology Knauf Data Sheet AH-DS-12e 09-09 Sonic XP Duct Liner with ECOSE Technology Consistent blanket thickness and uniform fiber distribution provides efficient and hassle-free cutting and pinning on all fabrication

More information

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Insulation Board. Knauf Data Sheet PE-DS

Insulation Board. Knauf Data Sheet PE-DS Insulation Board Knauf Data Sheet PE-DS-2 12-06 Insulation Board Description Knauf Insulation Board is a thermal and acoustical insulation product made from inorganic glass fibers preformed into boards

More information

SECTION HVAC INSULATION

SECTION HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY SECTION 23 07 00 HVAC INSULATION A. Section Includes: 1. Ductwork insulation. 2. Duct liner. 3. Insulation jackets. 4. Equipment insulation 5. Piping system insulation. 6. Insulation

More information

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT

AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT AIR DISTRIBUTION SOLUTIONS QUIETR ECOTOUCH SOFTR PROCAT Owens Corning Air Distribution Solutions 3 EcoTouch Insulation for Flexible Duct 4 QuietR Duct Board 5 ProCat Blown-in Insulation System 6 QuietR

More information

FM APPROVED. FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations

FM APPROVED. FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations FIRE PERFORMANCE Differences Between Elastomeric and Polyethylene/Polyolefin Insulations Why a 5/50 rating alone does not assure fire safety FM APPROVED FIRE PERFORMANCE: A 5/50 RATING DOES NOT ASSURE

More information

HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT

HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT HIGH PERFORMANCE ACOUSTIC INSULATING MATERIAL FOR A QUIETER ENVIRONMENT Excellent at reducing the transmission of airborne sound Enhances the insertion loss performance of pipe insulation Flexible, easy

More information

Air Handling Products

Air Handling Products Full Line Catalog AH-FL-11 05-07 Air Handling Products Air Duct Board-M and AGM, Duct Liner E M, Textile Duct Liner, Rigid Plenum Liner and Duct Wrap A Full Line of Air Handling Products Delivering greater

More information

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS

Air Duct Board-M with Hydroshield Technology. Knauf Data Sheet AH-DS Air Duct Board-M with Hydroshield Technology Knauf Data Sheet AH-DS-6 08-06 Knauf Air Duct Board-M is faced with a tightly bonded black mat for greater airstream surface durability. Available in both EI-475

More information

Redi-Klad 1000 Pipe Insulation

Redi-Klad 1000 Pipe Insulation Knauf Data Sheet PE-DS-16e 12-09 Redi-Klad 1000 Pipe Insulation with ECOSE Technology Knauf Redi-Klad 1000 F Pipe Insulation with ECOSE Technology is offered across a wide range of sizes. For iron pipe

More information

COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE

COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE COMPARISON GUIDE TO NON-FIBROUS LINER PERFORMANCE Performance Counts Selection of a duct lining can be a challenging step in the design process of a building s HVAC system today. Fibrous liners like Johns

More information

Ammonia. Product performance for insulation of ammonia piping

Ammonia. Product performance for insulation of ammonia piping Ammonia Product performance for insulation of ammonia piping ABOUT K-FLEX USA K-FLEX USA IS A LEADING MANUFACTURER of flexible, closed cell elastomeric insulation for mechanical piping, air handling units

More information

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

PITTWRAP CF JACKETING Product Datasheet

PITTWRAP CF JACKETING Product Datasheet PITTWRAP CF JACKETING Product Datasheet 1. Description and Area of Application PITTWRAP CF jacketing is a cellulose free fiberglass reinforced vapor retarder insulation jacketing, used for protecting above

More information

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS

Eclipse TM Air Duct Board. Knauf Data Sheet AH-DS Eclipse TM Air Duct Board Knauf Data Sheet AH-DS-10 01-08 Eclipse Air Duct Board Description Knauf Eclipse Air Duct Board is a rigid fiber glass board faced on one side with a foil-scrim-kraft (FSK) vapor

More information

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology Knauf Data Sheet PE-DS-2e 8-09 Insulation Board with ECOSE Technology Insulation Board with ECOSE Technology Description Knauf Insulation Board with ECOSE Technology is a thermal and acoustical insulation

More information

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION PART 1 GENERAL 1.01 SUMMARY Section 15145 This Section includes insulation for piping and equipment as called out on the Plans. 1.02 MEASUREMENT AND PAYMENT No separate payment will be provided for the

More information

B. Refer to Section : Air Distribution for lined ductwork requirements.

B. Refer to Section : Air Distribution for lined ductwork requirements. SECTION 230700 MECHANICAL INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology Knauf Data Sheet CI-DLS-DS 04-14 Sonic XP with ECOSE Technology Duct Liner Sonic XP Duct Liner with ECOSE Technology Description Knauf Insulation Sonic XP Duct Liner is a flexible, mat-faced insulation

More information

SUPAFLEX SUPAFLEX DESCRIPTION TUBING:

SUPAFLEX SUPAFLEX DESCRIPTION TUBING: SUPAFLEX SUPAFLEX SUPAFLEX DESCRIPTION SUPAFLEX Closed Cell Tubing & Sheet Insulation is a flexible and light weight elastomeric thermal insulation designed for insulating liquid cooling and heating lines,

More information

TAPE SOLUTIONS FOR HVAC SHURTAPE.COM TAPE

TAPE SOLUTIONS FOR HVAC SHURTAPE.COM TAPE TAPE SOLUTIONS FOR HVAC SHURTAPE.COM 1.888.442.TAPE YOU DEMAND FULL SYSTEM CLOSURE. And rely on tape to get the job done quickly and efficiently. That s why we offer a full portfolio of foil, film and

More information

SECTION PIPING INSULATION

SECTION PIPING INSULATION SECTION 23 07 19 PIPING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Piping insulation for refrigerant piping within building envelope. 2. Furnishing and installation of insulation.

More information

KwikFlex Pipe & Tank Insulation. Knauf Data Sheet PE-DS

KwikFlex Pipe & Tank Insulation. Knauf Data Sheet PE-DS KwikFlex Pipe & Tank Insulation Knauf Data Sheet PE-DS-15 04-07 Knauf KwikFlex offers a unique combination of fl exibility and compressive strength in a blanket form. Tough and durable, yet easy to handle

More information

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l P r o d u c t C a t a l o g w w w. p i p e i n s u l a t i o n. n e t B C M T e c h n i c a l, L L C 2 1 7 5 A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I 4 8 3 0 9 P h o n e : 2 4

More information

Thermasheath-XP. Insulation for Exposed Use

Thermasheath-XP. Insulation for Exposed Use Insulation for Exposed Use PRODUCT DESCRIPTION Rmax Thermasheath-XP is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam bonded to durable, embossed

More information

Atmosphere Duct Liner

Atmosphere Duct Liner Data Sheet CI-DLA-DS 02-15 Atmosphere Duct Liner with ECOSE Technology Atmosphere Duct Liner with ECOSE Technology Description Knauf Insulation Atmosphere Duct Liner is a flexible, mat-faced insulation

More information

An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor

An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor applications. Description Dual-Tech TM is an all-in-one,

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

YOUR FIBERGLASS SOLUTIONS PROVIDER PRODUCT CATALOG

YOUR FIBERGLASS SOLUTIONS PROVIDER PRODUCT CATALOG www.quietflex.com FIBERGLASS YOUR SOLUTIONS PROVIDER PRODUCT CATALOG LNG LNG Resilient Blanket LNG Suspended Deck Blanket Quietflex Brand LNG Resilient Blanket is designed to offer excellent resiliency

More information

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment

PRODUCT CATALOGUE PROFLEXR. Thermal Insulation. CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment PRODUCT CATALOGUE PROFLEXR Thermal Insulation CFC free HCFC free Zero Ozone Depletion Potential (ODP) Taking care of energy and Environment PROFLEX Proflex polyolefin foam thermal insulation for AirConditioning,

More information

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS Dyplast Products Copyright 2014 1 Rev 0414 DYPLAST PRODUCTS INSTALLATION GUIDELINES ISO-C1 POLYISOCYANURATE

More information

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS Dyplast Products Copyright 2018 1 Rev 0618 DYPLAST PRODUCTS INSTALLATION GUIDELINES ISO-C1 POLYISOCYANURATE

More information

Data Sheet CI-DWA-DS Atmosphere. Duct Wrap. with ECOSE Technology

Data Sheet CI-DWA-DS Atmosphere. Duct Wrap. with ECOSE Technology Data Sheet CI-DWA-DS 10-15 Atmosphere with ECOSE Technology Duct Wrap Atmosphere Duct Wrap with ECOSE Technology Description Knauf Insulation Atmosphere Duct Wrap with ECOSE technology is a thermal and

More information

Quality NBR Insulation

Quality NBR Insulation Quality NBR Insulation Thickness Guide for Condensation Control Recommended Thickness (mm) for Condensate, Chilled Water and Refrigeration Systems Ambient Temperature 26 o C 30 o C 35 o C Relative Humidity

More information

KwikFlex Pipe & Tank Insulation

KwikFlex Pipe & Tank Insulation Knauf Data Sheet PE-DS-15e 12-09 KwikFlex Pipe & Tank Insulation with ECOSE Technology Knauf KwikFlex offers a unique combination of flexibility and compressive strength in a roll form. Tough and durable,

More information

Fire Protection Products

Fire Protection Products wwww Fire Protection Products Product Data Sheet April / 2017 Product Description Product Features Applications Specifications 3M Fire and Water Barrier Tape is a self-adhered membrane that provides a

More information

Praval Adhaulia K-FLEX INDIA PVT LTD

Praval Adhaulia K-FLEX INDIA PVT LTD Praval Adhaulia K-FLEX INDIA PVT LTD IK Insulation Group - Corporate - 2009 Thermal and Acoustic Products Thermal Insulation Is a material having relatively high resistance to heat flow Stationary air

More information

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation. SECTION 15083 HVAC DUCT PROTECTION OVER INSULATION FlexClad This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812 Toll

More information

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

1. Division 23 Section Hangers and Supports for HVAC Piping and Equipment for pipe insulation shields and protection saddles. SECTION 23 07 19 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER Dyplast Products Copyright 2012 1 Rev 0112 DYPLAST PRODUCTS

More information

ITW INSULATION SYSTEMS

ITW INSULATION SYSTEMS ITW INSULATION SYSTEMS 1SCOPE TRYMER RIGID POLYISOCYANURATE INSULATION IN LIQUEFIED NATURAL GAS APPLICATIONS (-260 F) 1.1 This guideline covers the installation of Trymer* Rigid Polyisocyanurate Insulation

More information

PRODUCT SELECTION GUIDE. HVAC Insulation

PRODUCT SELECTION GUIDE. HVAC Insulation PRODUCT SELECTION GUIDE HVAC Insulation TABLE OF CONTENTS DUCT LINER INSULATION Linacoustic RC 3 Linacoustic RC-HP 3 Linacoustic R-300 3 Spiracoustic Plus 4 Spiral SG 4 LinaTex 4 DUCT BOARD INSULATION

More information

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology Knauf Data Sheet PE-DS-2e 4-10 Insulation Board with ECOSE Technology o Shrinkage (ASTM C 356) Less than 0.3% linear shrinkage. Resists Microbial Growth (ASTM C 1338, G21) Does not promote or support the

More information

State of Alaska Section State Office Building HVAC Fan Replacement MECHANICAL INSULATION

State of Alaska Section State Office Building HVAC Fan Replacement MECHANICAL INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Specific requirements, products and methods of execution which relate to the insulation of ductwork, piping, valves and fittings. B. Related Sections:

More information

RELIABLE, FLEXIBLE INSULATION TRUSTED TO PREVENT CONDENSATION

RELIABLE, FLEXIBLE INSULATION TRUSTED TO PREVENT CONDENSATION Closed-cell structure increases resistance to water vapor Reduce long-term heat gain and reduce energy loss Engineered wall thickness operates with the same line temperature in the same environment Thermal

More information

SECTION MECHANICAL INSULATION

SECTION MECHANICAL INSULATION SECTION 15250 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems. Does not promote nesting of insects or rodents

APPLICATIONS Rectangular and Round return and supply ductwork in HVAC systems. Does not promote nesting of insects or rodents R-6.0 SUBMITTAL SHEET Hard Plastic Spacers D U C T I N S U L A T I O N R - 6. 0 Features AT A GLANCE: Reflectix Duct Insulation may be installed by wrapping rectangular or round ductwork in HVAC applications

More information

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

TSX Insulation for Exposed Use ROOF WALL SPECIALTY TSX-850 Insulation for Exposed Use ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax TSX-850 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam core bonded

More information

FlexClad Duct and Pipe Sealing System

FlexClad Duct and Pipe Sealing System FlexClad Duct and Pipe Sealing System Proven Performance Outperforms Metal Jacketing Waterproof & Weather-Resistant Ideal For Indoor & Outdoor Applications Quick & Easy Self-Stick Installation Meets 25/50

More information

Pipe & Equipment Insulations Product Selection Guide

Pipe & Equipment Insulations Product Selection Guide Fiber Glass Insulation Pipe & Equipment Insulations Product Selection Guide Icon Key Thermal Acoustical Fire Resistance Moisture Control Formaldehyde-free products for improved indoor air quality For more

More information

1 of 17. PO Box Bellevue Rd, Newark, DE V F

1 of 17. PO Box Bellevue Rd, Newark, DE V F 1 of 17 Raw Material Manufactured from 4 8-foot sheets Fiber-reinforced 1-mil aluminumfaced polyisocyanurate panels 0.032 embossed aluminum Other patterns and stainless steel are available Necessary supplies

More information

ITW INSULATION SYSTEMS

ITW INSULATION SYSTEMS ITW INSULATION SYSTEMS 1SCOPE TRYMER RIGID POLYISOCYANURATE INSULATION IN LIQUEFIED NATURAL GAS APPLICATIONS (Cryogenic to -70 F) 1.1 This guideline covers the installation of TRYMER Rigid Polyisocyanurate

More information

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700 SECTION 23 0700 - HVAC INSULATION PART 1 - GENERAL 1.1 DESCRIPTION OF WORK: A. All work covered in this section consists of furnishing all labor, equipment, materials and accessories, and performing all

More information

University of Delaware

University of Delaware University Contact: Energy & Engineering Group (302) 831-1744 SECTION 23 07 00_ HVAC INSULATION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Piping system insulation. 2. Equipment insulation. 3.

More information

FLEXIBLE ARMAFLEX INSULATION WITH OUTER COVERING TO WITHSTAND MECHANICAL IMPACT. Protection against mechanical damage

FLEXIBLE ARMAFLEX INSULATION WITH OUTER COVERING TO WITHSTAND MECHANICAL IMPACT. Protection against mechanical damage ArmaFlex Tuffcoat FLEXIBLE ARMAFLEX INSULATION WITH OUTER COVERING TO WITHSTAND MECHANICAL IMPACT Protection against mechanical damage Can be used on underground pipework, including mains cold water and

More information

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness. SECTION 15250 PIPING AND EQUIPMENT INSULATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division 1 Specification

More information

Eclipse Air Duct Board

Eclipse Air Duct Board Knauf Data Sheet AH-DS-10e 03-12 Eclipse Air Duct Board with ECOSE Technology Eclipse Air Duct Board with ECOSE Technology Description Knauf Insulation Eclipse Air Duct Board with ECOSE Technology is a

More information

REFERENCE ARMA-CHEK SILVER

REFERENCE ARMA-CHEK SILVER REFERENCE ARMA-CHEK SILVER LENZING GROUP S LYOCELL FIBRE PLANT www.armacell.com Arma-Chek Silver in the world s largest lyocell plant Austrian Vöcklabruck district is the site of Europe s biggest ever

More information

REFERENCE ARMA-CHEK SILVER

REFERENCE ARMA-CHEK SILVER REFERENCE LENZING GROUP S LYOCELL FIBRE PLANT www.armacell.com Arma-Chek Silver in the world s largest lyocell plant Austrian Vöcklabruck district is the site of Europe s biggest ever Arma-Chek project

More information

INSTALLATION GUIDELINE FOR TRYMER INSULATION

INSTALLATION GUIDELINE FOR TRYMER INSULATION INSTALLATION GUIDELINE FOR TRYMER INSULATION TRYMER RIGID POLYISOCYANURATE INSULATION IN CHILLED WATER APPLICATIONS (35 F to 60 F) 1 SCOPE 1.1 This guideline covers the installation of Trymer Rigid Polyisocyanurate

More information

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project. I. GENERAL ACRYSHIELD SPF ROOFING SYSTEM Installation Guide Specification SPF Vapor Retarder System 07500 Saving Money, Safeguarding the Environment One Roof at a Time. 1.01 SUMMARY A. Provide labor, materials,

More information

ALUGLASS DUCT SYSTEM (KADS)

ALUGLASS DUCT SYSTEM (KADS) ALUGLASS DUCT SYSTEM (KADS) A NEW GENERATION PRODUCT www.kimmcoinsulation.com www.alghanim.com ALUGLASS DUCT SYSTEM (KADS) APPLICATION KIMMCO Aluglass Duct System used for air distribution in HVAC system

More information

CertaPro Thermal FSK-25 Faced Batts

CertaPro Thermal FSK-25 Faced Batts CertaPro Thermal FSK-25 Faced Batts ASTM C 553, Type I ASTM C 665, Type III, Class A, Category 1 New York City MEA 19-80-M Light-density fiber glass batts with a foil scrim kraft (FSK) fire resistant vapor

More information

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING Fire tested for vertical pipe chases to NFPA274 Complies with National Construction Code (NCC) Low thermal conductivity,

More information

Mechanical Insulation for Refrigeration Systems

Mechanical Insulation for Refrigeration Systems Mechanical Insulation for Refrigeration Systems INDUSTRIAL REFRIGERATION CONSORTIUM RESEARCH & TECHNOLOGY FORUM MAY 2-3, 2012 Peter Gauchel, President/CEO L&C Insulation Inc. Overview Current trends in

More information

SECTION PLUMBING INSULATION

SECTION PLUMBING INSULATION SECTION 22 07 00 PLUMBING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section includes equipment insulation, covering, and thermal insulation for piping systems including vapor retarders, jackets and accessories.

More information

Air and Vapor Barrier 3015

Air and Vapor Barrier 3015 Air and Vapor Barrier 3015 Technical Data March 2017 Product Description 3M Air and Vapor Barrier 3015 is an air, moisture and water impermeable membrane with an aggressive, high-tack acrylic pressure

More information

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulation, membrane roofing, base flashings roofing membrane accessories joints, and counter flashings.

More information

PERMATHERM PIPE INSULATION PRODUCTS

PERMATHERM PIPE INSULATION PRODUCTS PERMATHERM PIPE INSULATION PRODUCTS PERMATHERM, INC. 269 Industrial Park Road Monticello, GA 31064 (706) 468-7500 www.pipe-insulation.net September 2012 This Specification Guideline in the 3-Part Format

More information

ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS

ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS 23 07 13 ACOUSTICAL DUCT & PIPE LAGGING INDUSTRIAL NOISE CONTROL PRODUCTS ACOUSTICAL DUCT AND PIPE LAGGING Acoustical Lagging is wrapped around the outside of duct or pipe to reduce the radiated noise

More information