1 Architect s Supplemental Instructions Number: ASI 015 Date Issued: February 10, 2015 KPFF Project Number: Project: UW Montlake Triangle To Contractor, The Work shall be carried out in accordance with the following supplemental instructions issued in accordance with the Contract Documents. Proceeding with the Work in accordance with these instructions indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time unless Owner is notified and agrees otherwise. Attachment Descriptions: Specification Section Painting and Coating: Addition of concrete skim coat product and paint colors PNT-2, and PNT-3. LSK-037 Revision to landbridge and adjacent site wall finish system and locations of finish. L110 Revision to landbridge and site wall finishes and locations of finish, including landbridge soffit. Issued By: Puja Shaw, Associate (Signature) (Printed name and title)
2 Page 1 of 8 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Preparation of surfaces. 2. Preparation and painting of exterior concrete where indicated. B. Related Sections: The work of the following Sections is related to the work of this Section. Other Sections, not referenced below, may also be related to the proper performance of this work. 1. Section , Cast-In-Place Concrete 2. Section , Architectural Concrete 3. Section , Exterior Steel Coatings 1.2 DEFINITIONS A. DFM (dry film mils): Minimum thickness, measured in mils, of a coat of paint in the cured state. B. Gloss Levels: The following terms are used to specify specular gloss of finish coats in accordance with those listed by MPI (Master Painter Institute) when measured in accordance with ASTM D523. Gloss Level 1.3 SUBMITTALS Description 60 degrees Level 1 Traditional matte finish - flat Level 2 High side sheen flat a velvetlike finish Level 3 Traditional eggshell-like finish 85 degrees Maximum 5 units and Maximum. 10 units Maximum 10 units Level 4 Satin-like finish units Level 5 Traditional semigloss and units units and units units Level 6 Traditional gloss units Level 7 High gloss More than 85 units A. Procedures: Section , Submittal Procedures. and Minimum 35 units B. Product Data: Submit complete list of products proposed for use, including technical data on each product to verify compliance; organize list to indicate painting systems to be used with each substrate.
3 Page 2 of 8 1. Submit paint list with paint manufacturer, paint name, coverage and VOC content listed. 2. Submittal shall contain any proposed revisions to Contract Specifications (for example surface preparation, and method of application) which painting contractor feels are necessary in their execution of the Contract. 3. All proposed revisions must be approved by the Engineer prior to proceeding with the Work. 4. The submission of paint product data is to be in conjunction with steel submittals where the steel is being painted. This is to confirm that the shop applied steel primer is compatible with the intermediate coat and final paint coats. This submittal will not be considered complete and acceptable if either product is not compatible with each other. C. Samples: Using approved paint products, prepare and submit samples of each type of finish, gloss level, and color for approval. Refer to Article 2.04, herein, for requirements. Label samples with color number, product name and date. Provide three samples of each color and sheen. 1. Prepare paint samples on 8-1/2 inch by 11-inch heavy, durable non porous paper. 2. Adjustments to the overall sheen in one or more of the colors may be required. Such adjustments (if any) shall be made at no additional cost. Additional samples will be required should adjustments be made. 3. Initial color samples which have been approved are subject to final acceptance at time of field mock-up examination. D. Contract Closeout Submittal: Include the following at time of Project Closeout: 1. Extra Materials: Coordinate submittal of extra maintenance materials with requirements of Section , Closeout Procedures and herein, for quantities and other requirements. 2. Color Mix: Submit color mix formula for each required paint color. Mix formula must be in measured increments of 48ths of an ounce; include the manufacturer's color and number identification, color chip, location list where said colors were applied and paint manufacturer of base. 1.4 QUALITY ASSURANCE A. Single Source: 1. To the maximum extent practicable, select a single manufacturer to provide all materials required by this Section, using additional manufacturers to provide systems not offered by the selected principal manufacturer. 2. For each individual system, provide primer and other undercoat paint produced by same manufacturer as finish coat. Use only thinners approved by paint manufacturer and use only within recommended limits.
4 Page 3 of 8 B. Visual Standards: Each distinct area of the finished Work shall be free of variations in color and sheen, runs, sags, holidays, blistering, checking, cracking, scratches and other signs of poor workmanship. Deep tone and accent color walls shall be free from joint banding, flashing, photographing, and uneven appearance. C. Mockups: Apply benchmark samples of each paint system indicated and each color and finish selected to verify preliminary selections made under sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution. 1.5 DELIVERY, STORAGE & HANDLING A. Deliver materials to building in sealed, original, labeled containers bearing manufacturer's name, type of material, brand name, color designation, and instructions for mixing and thinning. B. Store materials when not in actual use in a place specifically assigned for that purpose which is dry and out of direct sunlight. Store materials in a manner so as not to exceed the manufacturer's temperature limitations. 1.6 PROJECT CONDITIONS A. Environmental Conditions: Air temperature and substrate temperature and relative humidity shall be within the manufacturer s established limits. Do not apply exterior paint when the following conditions exist, unless requirements of paint manufacturers are more restrictive. 1. Temperature: If surface and ambient temperature is above 90 degrees F, or below 50 degrees F. 2. Weather: Do not apply paint in snow, rain, fog, when excessively windy or during mist; or when relative humidity exceeds 85 percent; or at temperatures less than 5 degrees F above the dew point; or to damp or wet surfaces. B. Lighting: Do not proceed with work under this section unless adequate lighting is available. Provide lighting level of at least 50 candlepower per square foot, measured mid-height at substrate surface. C. Ventilation: Provide adequate ventilation as required for the type of paint and cleaning materials used. If necessary, consult paint manufacturer for recommendations. D. Protection: Protect surrounding areas against damage due to painting operations. At a minimum, surrounding areas shall be covered with polyethylene sheeting and waterproof masking tape. Sound Transit will not be responsible for the Contractor's selection or method of protection. 1. Protective coverings shall be secured against wind and shall be vented to prevent collection of moisture on covered surfaces. 2. Provide "wet paint" signs as required to protect newly painted surfaces. E. Precautions: Take all precautions to prevent fire; open containers of flammable materials only when needed; keep rubbing cloths and oily rags in tightly closed containers and remove from site daily. Dispose of hazardous materials in accordance with all local, State and Federal regulations.
5 Page 4 of 8 F. Coordination: Review other sections of herein in which prime paints are to be provided to ensure compatibility of total coating system for various substrates. Notify Engineer in writing of any anticipated problems using specified coating systems with substrates primed by others. 1.7 EXTRA MATERIALS A. Supply five gallons of each paint type and color; store where directed. B. Label each container with color and color mix number in addition to the manufacturer's label. PART 2 - PRODUCTS 2.1 PAINT MATERIALS - GENERAL A. Manufacturers: Refer to Paint Schedules at end of this Section for manufacturer s product names and paint systems which are included to establish the required level of quality. Additionally the following list of manufacture s are acceptable, contingent upon meeting level of paint quality indicated in the Paint Schedules, and for which a substitution request is not required. 1. ICI Dulux Paints / Devoe Performance Coatings 2. Benjamin-Moore 3. Kelly-Moore Paints. 4. Sherwin Williams: 5. Tnemec Company. 6. Rodda Paint B. Paint Grade: Professional grade coatings meeting the equivalent performance requirements listed in the Master Painter Institute Approved Product List and suitable for its intended use. C. Colors: Each paint color must be accurately mixed to ensure color continuity. No allowance will be granted for mismatched paint of the same color when viewed under normal lighting conditions. D. Provide primer and finish coats, which are compatible with each other and with prime coats provided under other Sections. Provide barrier coats over incompatible primers or remove and re-prime as required. E. Thinner: Type as recommended by the paint manufacturer. Use thinner only when recommended by the paint manufacturer, and then only in a quantity as indicated on the label. F. Primers: Primers, except metal primers, shall be white in color for inspection purposes. 2.2 PRIMERS AND UNDERCOATS A. Concrete and Concrete Masonry (CMU) Primer: ICI Devoe Bloxfil 4000 HD Acrylic, Tnemec Envirofill Series 130 or approved equal latex masonry filler.
6 Page 5 of 8 1. Gloss: Matte, MPI Level VOC limit: 100 g/l. 3. Nominal 8 mils DFM. a. Coverage - CMU: 75 s.f. per gallon. b. Coverage - Concrete: 100 s.f. per gallon. B. Anti-Corrosive Metal Primer (Includes Ferrous and Non-Ferrous Metals): ICI Devoe Devflex 4020 PF DTM, Tnemec Uni-Bond DF Series 115, or approved equal acrylic, rust-inhibitive primer recommended by manufacturer for use on both ferrous and nonferrous metals. 1. VOC limit: 91 g/l. 2. DFM: mils. 3. Adhesion: Minimum rating of 5 when tested in accordance with ASTM D 3359, Method B on all of the following surfaces: a. Steel prepared in accordance with SSPC SP-10. b. Aluminum prepared in accordance with SSPC SP-1. c. Galvanized steel prepared in accordance with SSPC SP-1. C. Waterborne Acrylic Stain: One of the following or approved: 1. Chemprobe/Tnemec Series 617 "Conformal Stain WB". 2. United Coatings "Canyon Tone Stain". 3. Tamms "Aqua Stain". D. Bridge Fascia Walls Concrete Skim Coat: 1. Ardex Tilt Patch. 2.3 PAINT COLORS A. Match the following concrete paint from SP1: B. PNT-2 C. PNT-3 1. PNT-1: Concrete Gray a. WSDOT "Washington Gray" 1. Canyontone Satin, product # a. Color: #0549 Emu. 1. Rodda Multi Master DTM Semi Gloss a. Color: #0549 Emu.
7 Page 6 of 8 PART 3 - EXECUTION 3.1 EXAMINATION A. General: Examine surfaces to receive paint finish for conditions that will adversely affect execution, performance, or quality of work and which cannot be put into an acceptable condition through reasonable preparatory work as specified herein. 1. Surfaces which are unfit to receive the work of this section shall be repaired, replaced or re-finished such that they are acceptable and such that the work of this section may be done as specified. It shall be the responsibility of the Contractor to ensure that these provisions are strictly enforced. 2. Commencement of Work constitutes acceptance of surfaces and conditions. B. Concrete and Masonry: 1. Alkali Content Testing: Test for alkalinity by performing appropriate tests, and neutralize as required for ph reading between 6.8 and 8.0, unless otherwise recommended by paint manufacturer. Test for ph following test method as described in ASTM D4262, utilizing litmus paper. 2. Moisture Content Testing: Test for moisture content by performing appropriate tests. Maximum moisture content shall not exceed 17 percent as determined by a moisture meter, unless otherwise required by paint manufacturer. 3.2 SURFACE PREPARATION (GENERAL) A. General: Surface preparations and cleaning procedures shall be in strict accordance with the instructions and specifications of the paint manufacturer and with the requirements herein. B. Painting of Factory-Primed Door Hardware: Prior to painting, mask all operating parts so that item works freely after paint is dry. Remove allexcess paint from operating parts and clean and free-up the operation of all parts which do not operate smoothly due to the painting operation. 3.3 SURFACE PREPARATION A. Uncoated Ferrous Metal: Thoroughly degrease surfaces using solvent (SSPC-SP 1) and remove rust and foreign matter by scraping, sanding, wire brushing, or other abrasion methods as necessary in accordance with SSPC-SP 2 and SSPC-SP 3. Remove pits and clean to bright metal before priming. Apply primer on the same day. B. Shop-Coated Ferrous Metal: Thoroughly degrease surfaces and clean using solvent (SSPC-SP 1). Remove loose rust, blistered and peeling paint to bare metal by scraping, sanding, wire brushing, or other abrasion methods in accordance with SSPC-SP 2 or SP 3; feather edges of adjacent sound paint. Dull glossy surfaces by scuff-sanding and wipe down. Spot-prime all abraded portions, rust areas, and bare surfaces with specified primer on same day. C. Galvanized Metal (Unpainted): Clean surfaces, wash and etch, to remove factory films and oily residue as recommended by the paint manufacturer. Responsibility for insuring that the surface is properly prepared rests with the painting Subcontractor. Clean galvanized metal the same day to be painted. If a pretreatment wash primer is recommended by manufacturer, apply pretreatment not more than 8 hours in advance of applying primer.
8 Page 7 of 8 D. Concrete: Clean surfaces free from dirt, grease, oil, efflorescence, and other foreign substances. Remove mortar droppings, glaze, and scale. 3.4 CLEANING PRIOR TO PAINTING A. Remove dust and loose deleterious materials from all surfaces before beginning painting operations. Program the cleaning and painting so that dust and other contaminants from the cleaning process will not fall in wet, newly painted surfaces. 3.5 APPLICATION OF PAINT A. Mixing: Mix paint materials in accordance with the manufacturer's instructions and directions. Mix often enough during application to keep the paint uniform and to ensure complete dispersion of pigment and a uniform composition. 1. Prepare multiple component coatings using all of the contents of the container for each component as packaged by the manufacturer. Mixing of partial kits will not be permitted. Multiple component coatings that have been mixed shall not be used beyond their pot life. Only the components specified and furnished by the manufacturer, including thinner if required, shall be mixed. B. Application: Apply paint in accordance with the manufacturer's directions. Use techniques best suited for substrate and type of material being applied. Brushes and rollers shall be of a type best suited for the type of material being applied. 1. Apply intermediate and finish coats within the manufacturer's recommended top coating time periods. C. Apply each coat of paint as a continuous film of uniform thickness, free from holidays, sags, crawls, pinholes, blisters, unevenness in color, or other evidence of poor workmanship. Repaint thin spots or areas missed in the application and allow to dry before applying next coat of paint. 1. Give special attention to ensure that surfaces, such as edges, corners, crevices, welds and exposed fasteners receive a dry film thickness equivalent to that of flat surfaces. 2. Each coat shall be free of dirt, dust, moisture, and other contaminates prior to application of next coat. D. Allow each coat of paint to thoroughly dry, full thickness of the film, before application of the succeeding coat. Paint is considered dry for recoating when the next coat can be applied without the development of all detrimental film irregularities such as wrinkling, lifting, or loss of adhesion of the previous coat. E. Coverage for each paint material is specified as either the total minimum dry film thickness in mils, or the spreading rate in square feet per gallon over the surface designated. Actual coverage rate will vary depending upon the texture and porosity of the surface, and climatic conditions. 1. The number of coats specified is the minimum required, irrespective of the coating thickness. 2. In the event the required paint thickness is not achieved, or coating shows through, apply additional coats until the color appearance is uniform and required thickness is obtained. Cost for additional coats to prevent show through shall be borne by the Installer.
9 Page 8 of 8 3. Do not exceed manufacturer's recommended maximum film build-up per coat (wet mils). F. Make edges of paint adjoining other materials or colors clean and sharp with no overlapping. G. Do not paint over code-required labels or equipment identification or nomenclature plates. 3.6 DAMAGED PAINT SURFACES A. General: Before final acceptance of the work by the Engineer, repair or re-finish painted surfaces which have been damaged at no additional cost. B. Areas of chipped, peeled, or abraded paint shall be hand or power sanded, feathering the edges. Prime and finish coat the areas using the same material as originally scheduled. Depending on the extent of repair and its appearance, an overall finish coat may be required by the Engineer to achieve uniform appearance. 3.7 CLEAN-UP A. General: During the progress of the work, remove from the project all discarded paint materials, rubbish, cans and rags. Leave premises clean and in orderly condition. B. Cleaning: Upon completion of painting work, clean window glass and other paintspattered surfaces. Remove spattered paint by proper methods of washing and scraping, using care not to scratch or otherwise damage finished surfaces. 3.8 PAINT SCHEDULE - EXTERIOR SURFACES A. Typical Exposed Concrete (other than bridge soffit). Waterborne acrylic stain. 1. Primer: None required. 2. Two Finish Coats: Waterborne acrylic stain. END OF SECTION
10
11
A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:
ILLINOIS STATE UNIVERSITY CORDOGAN, CLARK & ASSOCIATES, INC. WATTERSON DINING EXPANSION PROJECT 960 RIDGEWAY AVENUE NORMAL, ILLINOIS AURORA, ILLINOIS CCA PROJECT NUMBER: 14362 630-896-4678 BID SET JULY
More informationThis Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:
0 0 0 0 0 0 SECTION 0 ANTI- GRAFFITI COATINGS PART - GENERAL RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division Specification
More informationELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION
ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions,
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 2 A solvent based coating system High Performance 9100/9800 System DTM Epoxy Mastic/DTM
More informationRD COATINGS -RD-ELASTOFLEX ELASTOMERIC ACRYLIC WALL COATING SPECIFICATION
RD COATINGS -RD-ELASTOFLEX ELASTOMERIC ACRYLIC WALL COATING SPECIFICATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions,
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 44 A solvent based coating system High Performance 7400 System 450 VOC DTM Alkyd Enamel
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 3 A solvent based coating system High Performance 9300/9800 System Extended Recoat Epoxy
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 23 A solvent based coating system High Performance 4315 High Heat Aluminum For service
More informationA. Section includes surface preparation and the application of paint systems on interior substrates.
SECTION 09 91 23 - INTERIOR PAINTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)
- 1 - SECTION 099600 High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes) PART 1 GENERAL 1.1 SECTION INCLUDES A. Systems for field applied acrylic urethane
More informationZONE 7 WATER AGENCY CWS 5 TURNOUT REPLACEMENT PROJECT # ADDENDUM NO. 3 April 02, 2019
ZONE 7 WATER AGENCY CWS 5 TURNOUT REPLACEMENT PROJECT # 275-18 ADDENDUM NO. 3 April 02, 2019 This Addendum No. 3 ( Addendum ) is dated the date set forth above and modifies certain Bidding Documents issued
More informationMDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls
MicroTex Eggshell Micro-Textured Ceramic Coating for Walls Specification Guide 95: 9770 Special Wall Finishes 88: 9800 Special Coatings Part 1 General 1.01 SUMMARY A. This section specifies the furnishing
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 099600 - HIGH PERFORMANCE COATINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationA. Section includes surface preparation and application of wood finishes[.]
SECTION 09 93 00 - STAINING AND TRANSPARENT FINISHING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 65 A solvent based coating system High Performance 9100 System 100 VOC DTM Epoxy Mastic
More informationVenger Electrostatic Coatings Master Specification Page 1
Master Specification Page 1 SPEC NOTE: Update references to Division 01 General Requirements specification sections to match actual section numbers and titles used for the project. SPEC NOTE: Venger permits
More information1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.
PAINTING GENERAL INFORMATION 1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats. DESIGN REQUIREMENTS 2.1 Material Compatibility: a. Provide materials
More informationSECTION PAINTING. A. Surface preparation and field application of paints and coatings at interior and exterior surfaces.
SECTION 09910 PAINTING 1 PART ONE - GENERAL 1.1 COORDINATION A. Drawings and General provisions of the Contract including General and Supplementary Conditions and Division 1 Specification Sections apply
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 09 - FINISHES
SECTION 099113 - EXTERIOR PAINTING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Concrete. 2. Concrete
More informationDAYTONA BEACH PIER BUILDING RESTORATION 06/10
SECTION 099113 - EXTERIOR PAINTING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel. 2. Galvanized
More informationVengerElectrostatic Coatings Master Specification Page 1
Master Specification Page 1 SPEC NOTE: Update references to Division 01 General Requirements specification sections to match actual section numbers and titles used for the project. SPEC NOTE: Venger permits
More informationSECTION HIGH PERFORMANCE COATINGS Ramuc Type EP Epoxy Updated October 5, 2015
Specification Provided To: Date: Job: PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 09 96 60 HIGH PERFORMANCE COATINGS Ramuc Type EP Epoxy Updated October 5, 2015 A. Paints and coatings of the following
More informationSECTION (09941) - TEXTURED FINISHING
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: SECTION 09 94 13 (09941) - TEXTURED FINISHING 1. Spray Applied Textured Finish and Primer a. Textured Finish for Ceilings. b. Textured Finish for Walls.
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 70 A solvent based coating system Concrete Saver 6200 System Fast-Cure Epoxy Floor Coating
More informationThe City of Winnipeg NEWPCC Lab Renovation
Bid Opportunity 253-2011 Page 1 of 6 Part 1 General 1.1 SUMMARY.1 Work under this contract includes, but is not necessarily limited to:.1 Surface preparation of substrates as required for acceptance of
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 20 A solvent based coating system Concrete Saver Anti-Slip High Performance Epoxy AS9100
More informationTEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING
SECTION 09960 - TEXTURED COATINGS Coating System Submittals Guide Specification TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING (SPLIT FACE OR SAND FINISH BLOCK) 1. TEX COTE 600, Textured Coating
More informationSECTION INTUMESCENT FIREPROOFING
SECTION 078123 INTUMESCENT FIREPROOFING PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. Work of this Section, as shown or specified, shall be in accordance with the requirements of the Contract Documents. 1.2
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 19 A 100% solids epoxy coating system Concrete Saver AS6500 System Anti-Slip 100% Solids
More informationSECTION PAINTING Ultra Premium
SECTION 09 90 00 PAINTING Ultra Premium PART 3-EXECUTION 3.01 PREPARATION: A. Perform preparation and cleaning procedures in strict accordance with coating manufacturer s instructions for each substrate
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 40 A water based coating system Sierra Performance S40 Water Based Epoxy Floor Coating
More informationSECTION DRY ERASE COATING (IdeaPaint CREATE Black and White) A. Section Gypsum Board Assemblies; gypsum board substrate.
Guide Specifications for Designers and Specifiers: This document specifies IdeaPaint CREATE Dry Erase Coating by IdeaPaint, and is provided for your use in CSI 3-Part Format. For further assistance, call
More informationSPECIFIER SHALL REMOVE COMMENTS IN BOLD TEXT PRIOR TO SUBMITTING.
This guide specification is to be used to develop an office master specification or specification for a project. In either case, this guide specification must be edited to fit the conditions of use. Particular
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 22 A solvent based coating system Concrete Saver AS5400Anti-Slip High One-Step Epoxy System
More informationAssociated Spec Consultants, Inc. February 27, 2014 SECTION ARCHITECTURAL COATINGS
SECTION 099650 ARCHITECTURAL COATINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationAcrylitex Tilt UP Primer Guide Specification Revised August 1, 2008
Acrylic Technologies, Inc. Telephone (503) 653.4061 Fax: (503) 552.1441 Website: www.acrylitex.com Specifier Note: This manufacturer's guide specification specifies Acrylitex Tilt UP Primer for interior
More informationProtective Industrial Polymers - USA Manufacturer s Specification February 11, 2015
This specification covers InhibiChem SR-GF-L Enhanced Chemical and Solvent-Resistant Glass-Flake Reinforced Steel Tank Lining System. This system consists of a vinyl ester primer, and two troweled coats
More information1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets
This specification covers InhibiChem CR-GF-L Chemical-Resistant Glass Flake-Reinforced Steel Tank Lining System. This system consists of a vinyl ester primer, and two troweled coats of glass flake filled
More informationInterior Painting Artesi II & III Day Care Facilities at 777 & 333 W. Matthews Road
Interior Painting Artesi II & III Day Care Facilities at 777 & 333 W. Matthews Road Introduction: The HACSJ is seeking quotes from licensed and bonded C-33 Interior/Exterior Painting Contractors to provide
More informationDist. by: BEST MATERIALS Ph:
Dist. by: BEST MATERIALS Ph: 800-474-7570 www.bestmaterials.com Email: Sales@BestMaterials.com NOVALINK SL SELF-LEVELING CONSTRUCTION SEALANT DIVISION 7 - THERMAL AND MOISTURE PROTECTION SECTION 07 92
More informationInternational Fireproof Technology Inc.
International Fireproof Technology Inc. The Ultimate in Firestop Solutions and Fire Protective Coatings www.painttoprotect.com 949-975-8588 Guide Specifications Alternate Thermal and Ignition Barrier IFRM
More informationCleaning and Protecting Concrete Surface Preparation, Application, and Inspection. NESMEA October 17, 2017 Kenneth A. Trimber KTA-Tator, Inc.
Cleaning and Protecting Concrete Surface Preparation, Application, and Inspection NESMEA October 17, 2017 Kenneth A. Trimber KTA-Tator, Inc. Cleaning and Protecting Concrete Surface Preparation, Application,
More informationSECTION EXTERIOR PAINTING PART 1 - GENERAL 1.1 SUMMARY
SECTION 099113- EXTERIOR PAINTING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes sutface preparation and the application of paint systems on the following exterior substrates: 1. Clay masonry. 2.
More informationSECTION WOOD WINDOWS
SECTION 08 52 00 WOOD WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1.2 DEFINITIONS 1. Repair of wood window sash, frames, and sills, including repair of deteriorated wood
More informationSKIMM /DUROFLOAT A High Performance Filling Compound For Interior Walls DST301. SKIMM / DUROFLOAT Specifications
SKIMM /DUROFLOAT A High Performance Filling Compound For Interior Walls SKIMM / DUROFLOAT Specifications NOTE TO SPECIFIER: 1) SKIMM is primarily used to fill and smooth irregular substrates such as CMU
More informationSECTION PAINTS AND COATINGS. 1.3 REFERENCES A. ASTM D 16 - Standard Terminology for Paint, Related Coatings, Materials, and Applications; 2000.
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Surface preparation. B. Field application of paints, stains, varnishes, and other coatings. C. See Schedule - Surfaces to be Finished, at end of Section. 1.2 RELATED
More informationRust-Oleum Industrial Brands Specification
Rust-Oleum Industrial Brands Specification Coating Specification for Rust-Oleum Virtual Solutions Coating Solution 14 A 100% solids epoxy coating system Concrete Saver 6500 System 100% Solids Epoxy For
More informationTerra Cotta Glaze Repair System
GUIDELINE FOR WRITING SPECIFICATIONS WHEN USING Terra Cotta Glaze Repair System Select Relevant Section Division 09800 or 099723 Paints and Coatings Part 1 GENERAL 1.1 DESCRIPTION Provide labor, materials
More informationSECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.
PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Fusion welded and rackable ornamental steel picket fence system. B. Related sections: 1. Section 03310 Concrete Work for post support. 2. Section 09960
More informationSECTION POLYPROPYLENE FABRIC WALL COVERING
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 09 72 31 POLYPROPYLENE FABRIC WALL COVERING SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph not
More informationReCote Finish System over Concrete
Part 1 General 1.01 GENERAL A. The Master Wall ReCote Finish System for smooth precast and cast in place concrete consists of an acrylic primer and ReCote acrylic finish. When needed an acrylic modified
More informationSECTION INTUMESCENT MASTIC FIREPROOFING
PART 1 GENERAL 1.01 SUMMARY SECTION 07 81 23 - INTUMESCENT MASTIC FIREPROOFING A. Section Includes: 1. Intumescent Mastic Fireproofing for Application to Exposed Steel 2. Protection of Adjacent Surfaces
More informationRESINOUS FLOORING
PART 1 - GENERAL 1.1 RELATED DOCUMENTS Bid #2017-17 A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More informationOlde Hickory 1, 2 & Hickory Hill Court Fort Myers, Fl Revised June 10, 2015
Prepared For: Tony Roller P and M Property Management 14360 South Tamiami Trail # B Fort Myers Fl. 33912 Fort Myers (239) 481-1577 / Naples (239) 596-7887 Fax # (239) 481-1789 Tony Roller
More informationMANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationMANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationPOLYURETHANE COATINGS ON STEEL OR DUCTILE IRON PIPE
Section 02527 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Two-component polyurethane coating system for use as external coating for steel or ductile iron pipe. 1.02 MEASUREMENT AND PAYMENT A. Unit Prices.
More informationROCKGRIP UNIVERSAL ACRYLIC PVA
TECHNICAL DATA SHEET Version 1 2016 FEBRUARY THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION Matt finish for interior use PRODUCT USES Suitable for use on primed new or previously painted
More informationCopyright 2018, The Sherwin-Williams Company ISSUED MAY CARB FLUID APPLIED FLOORING FOR CONCRETE THE SHERWIN-WILLIAMS COMPANY
Copyright 2018, The Sherwin-Williams Company ISSUED MAY 2018 09 67 00 CARB FLUID APPLIED FLOORING FOR CONCRETE THE SHERWIN-WILLIAMS COMPANY INDUSTRIAL INTERIOR SPECIFICATION GUIDE This Painting Schedule
More informationSECTION (07100) - DAMPPROOFING AND WATERPROOFING
SECTION 07 10 00 (07100) - DAMPPROOFING AND WATERPROOFING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Sheet Membrane Waterproofing 2. Under-Slab-On-Grade Vapor Barrier B. Related Sections: 1.02
More informationInternational Fireproof Technology Inc.
International Fireproof Technology Inc. The Ultimate in Firestop Solutions and Fire Protective Coatings www.painttoprotect.com 949-975-8588 Guide Specifications Alternate Thermal and Ignition Barrier IFRM
More informationPacific Polymers Elasto-Deck 5000X2 Guide Specification
1 071813-1 July 2018 Pacific Polymers Elasto-Deck 5000X2 Guide Specification SECTION 071813 TRAFFIC COATINGS ELASTO-DECK 5000X2 OVER CONCRETE 2 071813-2 July 2018 Pacific Polymers Elasto-Deck 5000X2 Guide
More informationList walls, planters, etc.., to which the anti-graffiti coating will be applied. Delete this note from the Contract Specifications.
X0321865 ANTI-GRAFFITI PROTECTION SYSTEM Effective: June 7, 2011 Revised: March 3, 2016 Description: This work shall consist of furnishing, and applying an anti-graffiti coating on all exposed faces of
More informationSECTION MULTICOLOR INTERIOR FINISHING
SECTION 09 94 19 MULTICOLOR INTERIOR FINISHING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes:
More informationSECTION Arisfor WallGuard
1.1 GENERAL A. is a three component polymerized cementitious protective coating that can be applied to a variety of vertical interior and exterior substrates including: stucco, exterior gypsum sheathing,
More information1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Tunnel Painting
1993 Specifications CSJ 8075-18-005 SPECIAL SPECIFICATION ITEM 4514 Tunnel Painting 1. Description. This Item shall govern for the painting of the walls and ceiling of a tunnel. The intent is to provide
More informationSECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.
SECTION 03460 EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE PART 1 GENERAL 1.1 SECTION INCLUDES A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels. B. Shop/Plant Cast CMU/Split Face
More informationSection COATING RESTORATION
80217R StoColor Lotusan Acrylic-Based, Vertical Above-Grade Exterior Wall Coating with Lotus-Effect Technology for Recoating Prepared, Previously Painted Surfaces Section 09 01 90.92 COATING RESTORATION
More informationSECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON
SECTION 055000 THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION 050001 MISCELLANEOUS AND ORNAMENTAL IRON PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a
More informationTnemec Standard Paint Schedule
Tnemec Standard Paint Schedule PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More information80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80212R StoColor Lastic Acrylic-Based, Elastomeric
More informationSection COATING RESTORATION
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80658R StoColor Texture - Coarse Textured Acrylic-Based,
More informationSECTION EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor
SECTION 09720 EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor PART 1.00 - GENERAL 1.01 GENERAL REQUIREMENTS A. Work of this Section, as shown or specified, shall be in accordance with
More informationGULF COAST PAINT MFG., INC
MCU-100 PRIMER/FINISH MOISTURE CURED URETHANE ALUMINUM COATING PRODUCT DESCRIPTION A one component, Moisture Cured Polyurethane Aluminum Coating. Has excellent adhesion to sound, tightly adherent rusty
More informationGrainger Stadium Club Building Kinston, NC Dunn & Dalton Architects Project # GRS-17048
August 31, 2017 Grainger Stadium Club Building Dunn & Dalton Architects Project # GRS-17048 RECEIPT OF THIS ADDENDUM MUST BE NOTED ON THE BID FORM ADDENDUM NO.1 TO ALL BIDDERS: This Addendum supplements
More informationSECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS
SECTION 07-9200 - JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More information80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80657R StoColor Texture Fine Textured Acrylic-Based,
More information80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80657R StoColor Texture Fine Textured Acrylic-Based,
More informationEND OF ADDENDUM 02 SPECIFICATION ITEMS
ALTA VIEW HOSPITAL EDUCATION CENTER BID DOCUMENTS - ADDENDUM 02 20 February 2019 - VCBO 18625 NEW SECTIONS A. ADD the following sections, issued herewith, to the Project Manual. Add section names and numbers
More informationARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound
ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound SECTION 03 01 30 MAINTENANCE OF CAST-IN-PLACE CONCRETE
More informationCONCRETE STEPS, HANDRAILS, AND SAFETY RAIL
CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART 1 - GENERAL 1.01 SECTION INCLUDES A. Concrete Steps B. Handrails C. Safety Rail 1.02 DESCRIPTION OF WORK A. Construction of concrete steps. B. Furnishing
More informationA. This Section includes traffic coatings for the following applications:
SECTION 071800 - TRAFFIC COATINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes traffic coatings for the following applications: 1. Interior and exterior, pedestrian traffic. 2. Vehicular traffic.
More information80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces
Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80201R StoColor Acryl Flat Acrylic-Based, Vertical
More informationSECTION A. American Society for Testing and Materials (ASTM):
hp.seal-krete.com 306 Gandy Rd., Auburndale, FL 33823-2723 800.323.7357 863.967.1535 fax:863-965.2326 Seal-Krete High Performance Epoxy-Shell 1000 Color System GUIDE SPECIFICATION SECTION 09725 PART 1
More informationASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS
ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS Re-Ply Roofing Systems Application Specification # AC - 2010-A & MB PART I GENERAL 1.01 DESCRIPTION A. This guideline specification includes
More informationCopyright 2018, The Sherwin-Williams Company ISSUED MAY OTC PHASE II INTERIOR HIGH PERFORMANCE COATINGS INDUSTRIAL COATINGS
Copyright 2018, The Sherwin-Williams Company ISSUED MAY 2018 09 96 00 OTC PHASE II INTERIOR HIGH PERFORMANCE COATINGS INDUSTRIAL COATINGS THE SHERWIN-WILLIAMS COMPANY INDUSTRIAL PAINTING SCHEDULE GUIDE
More informationCopyright 2018, The Sherwin-Williams Company ISSUED MAY SCAQMD HIGH PERFORMANCE COATINGS INDUSTRIAL PAINTING
Copyright 2018, The Sherwin-Williams Company ISSUED MAY 2018 09 96 00 - SCAQMD HIGH PERFORMANCE COATINGS INDUSTRIAL PAINTING THE SHERWIN-WILLIAMS COMPANY INDUSTRIAL PAINTING SCHEDULE GUIDE This Painting
More informationKolorines Glass Mosaic Tiles Project Specification
Kolorines Glass Mosaic Tiles Project Specification SUGGESTED SPECIFICATION Glass Mosaic Tile Installation for Swimming Pools NOTES TO SPECIFIER: 1. Specify PremiumPlus Thin-Set mixed with CustomFlex Additive
More informationAcrylitex Interior Texture and Coating Submittal Documentation
Acrylitex Interior Texture and Coating Submittal Documentation Project: Contractor: Installer: Supplier: John Wagner & Associates dba Grabber Construction Products 866-237-GRAB(4722) Distributor: Acrylic
More informationSpecifications. Specifications (Architectual) Metallic System. Metallic System
(Architectual) Metallic System Architectual NeverStrip Floor Coatings, 6-15 Mils Master Format Section 096700 Fluid Applied Flooring 1 of 6 NeverStrip Metallic High-Build Decorative Epoxy/Urethane Coating
More informationHAMMERITE NO. 1 RUST BEATER PRIMER
TECHNICAL DATA SHEET Version 2 2018 June THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS PRODUCT DESCRIPTION Hammerite No.1 Rust Beater provides a high build finish to heavily pitted areas of rust and
More informationAPPLICATION GUIDELINE
PROVEN ACRYLIC ROOFING SYSTEMdesigned to restore & protect metal roofs METAL To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins. PART 1 GENERAL 1.01 DESCRIPTION
More informationSECTION 1045 PAINT FOR STRUCTURAL STEEL
SECTION 1045 PAINT FOR STRUCTURAL STEEL 1045.1 Paint and Paint Material. 1045.1.1 General. All single component paints shall be ready-mixed at the factory to comply with the specification formula for the
More informationCarboxane 950 Metallic
SELECTION & SPECIFICATION DATA Generic Type Description Features Color Finish Primer Dry Film Thickness Fluorourethane Premium, ultra-durable ambient cured finish meeting performance requirements. 950
More informationADDENDUM TO THE CONTRACT. for the. East Valley Reservoir Exterior and Lemon Creek Reservoir Interior Repainting. Contract No.
ADDENDUM TO THE CONTRACT for the ENGINEERING DEPARTMENT East Valley Reservoir Exterior and Lemon Creek Reservoir Interior Repainting Contract No. E12-210 ADDENDUM NO.: ONE CURRENT DEADLINE FOR BIDS: May
More informationEducation Facility Guide Specification
Education Facility Guide Specification This Painting Schedule is furnished as a guide to select paint systems, and is not all-inclusive of available Sherwin-Williams products. Specifiers should review
More informationTECHNICAL DATA SHEET HYDROPOX #2 4:1 EPOXY (MPI #115)
TECHNICAL DATA SHEET HYDROPOX #2 4:1 EPOXY (MPI #115) DESCRIPTION: A two component water base epoxy amine coating that provides excellent adhesion, solvent resistance and abrasion resistance with water
More informationIFTI - Master Specification Section <IssueDate> Rev. June 2018
International Fireproof Technology, Inc. 17528 Von Karman Ave. Irvine, CA 92614 Office: 949-975-8588 IFTI SPEC NOTE: This master specification is written to include SPEC NOTES noted as IFTI Spec Note in
More informationSECTION A. American Society for Testing and Materials (ASTM):
hp.seal-krete.com 306 Gandy Rd., Auburndale, FL 33823-2723 800.323.7357 863.967.1535 fax:863-965.2326 Seal-Krete Vapor-Shell GUIDE SPECIFICATION SECTION 09725 PART 1 GENERAL 1.01 SECTION INCLUDES A. Provisions