Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles

Size: px
Start display at page:

Download "Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles"

Transcription

1 Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles LA03023 Rev 4

2 INTRODUCTION The Via-Cell sampler is a unique, multi-purpose particle collection device designed for the collection of both viable and non-viable bioaerosols. Using a proprietary water soluble collection media along with special environmental controls, the Via-Cell sampler is capable of collecting particles, maintaining the viability of spores during transport to the laboratory. The particles can then be analyzed using one or more analytical methods. APPLICATIONS Indoor Air Quality Allergy Testing Flood Restoration Clean Room Monitoring Hospital Infection Control Preloaded, sterile and ready for use. VIA-CELL ADVANTAGES Disposable, no equipment to clean between samples. Eliminates cross contamination concerns. Includes tamperproof safety seal to prevent sample contamination after collection. Each slide inside the sampler is marked with a unique serial number to ensure accurate sample traceability. Shelf life of 1 year from date of manufacture is 4 times longer than most sampling methods using culture plates. Allows multiple types of analysis to be performed from a single collected sample. Samples do not require refrigeration, only room temperature storage and transportation. Small, compact size. No heavy or bulky equipment is required. Can be used with virtually any kind of sampling pump capable of pulling a 15 lpm (vacuum) air flow, including battery powered pumps such as the Zefon Bio-Pump or Bio-Pump Plus. 2

3 ANALYSIS OPTIONS Culturable Sampling: PCR Analysis: Direct Microscopy: The Via-Cell sampler is the perfect tool for collecting viable organisms and culturing them on agar media plates. The Via-Cell utilizes a water soluable collection media which is ideal for PCR and other chemical types of analysis. Samples collected using the Via-Cell sampler may be pre screened using direct microscopy methods which allows the analyst to decide if additional analysis techniques are needed. 3

4 PRINCIPLES OF OPERATION The Via-Cell sampler operates on the well established principle of inertial impaction. Particles in the air stream are accelerated as they approach the tapered inlet opening and drawn through a small slit aimed directly at a glass slide. This glass slide contains a water soluable sampling media which is designed to hold particles intact and maintain viability for later analysis. As the particles come through the slit, the air velocity forces the particles to impact into the sampling media, while the air stream makes a sharp 90 o turn and proceeds around the slide and out of the cassette. The air flow path through the Via-Cell sampling cassette is illustrated below in Figure 1. Figure 1 AIR FLOW PATH OF THE VIA-CELL SAMPLER 4

5 OPERATIONAL PERFORMANCE The Via-Cell sampler has been evaluated in commercial and university laboratories to determine the collection efficiency and operational aspects of the collector. With impactor-type samplers, the most common measure of efficiency is defined by it s cut-point curve. The cut-point (also referred to as the D-50 point) is defined by the particle size at which 50% of the particles are collected and 50% pass through the sampler at a pre-determined flow rate. The cut point for the Via-Cell Sampler has been determined to be 1.56 microns at a flow rate of 15 LPM. This cut point is ideal for fungal analysis because particles smaller than this are not of interest, and may even create enough background debris to obscure adequate viewing of the sample and compromising reliable analysis. Figure µm at 97.8% 1.604µm at 77.1% 1.553µm at 45.1% 1.508µm at 26.4% 1.398µm at 7.1% The graph above displays the collection efficiency of the Via-Cell sampler when used at a flow rate of 15LPM. Samplers that are designed properly will exhibit upper and lower curve limits that are very sharp and in an ideal situation, a sampler will reach 100% efficiency almost immediately after the cut-point. The Via-Cell demonstrates a remarkably sharp curve that is superior to many other devices on the market today. 5

6 RECOMMENDED FIELD SAMPLING PROCEDURES The Via-Cell sampler is designed to efficiently collect bioaerosol particles while also providing safe transport to the laboratory. The results achieved when using the sampler requires proper use, including pump calibration and handling techniques. Therefore familiarization with the Via-Cell Sampler collection procedure is recommended prior to use. Required Sampling Equipment * Via-Cell Sampling Cassettes * Sampling pump capable of pulling 15LPM * Tubing to attach cassette to pump, if required (1/4 ID or 1/2 ID) * Pump calibration device Handling the Via-Cell Sampler: The Via-Cell Sampler is sterile and ready-to-use when received. It is very important not to contaminate the inner-surface of the cassette through careless handling, or insertion of anything into the cassette through the inlet or outlet port. While the collection may render the sampler not sterile due to the collected particles, the person doing the collection should not introduce spurious materials into the collection that could alter the outcome. Handling Tips and Considerations 1. Always store Via-Cell cassettes in climate controlled areas with a room temperature between degrees F. 2. The Via-Cell sampler does not require refrigeration during storage or during shipment to the analysis laboratory. 3. Prolonged exposure to high temperatures (e.g. as that in the trunk of a car or hot warehouse) may alter the performance of the product. 4. Use of the Via-Cell sampler in extreme environmental conditions (i.e. very hot or cold weather) may affect the collection performance. 5. Always ship Via-Cell samples to the laboratory so that the laboratory receives the samples within 24 hours after collection. The laboratory should process the samples within 24 hours of receipt. 6

7 EXPLODED VIEW OF VIA-CELL CASSETTE Figure 3 Blue Inlet Cap Controls environmental conditions during storage and transport. Remove immediately prior to sampling and replace immediately after sampling. Main Body (clear plastic section) This section holds the collection media and is the section used during sampling. Note: Plastic may have an amber tint. This is considered normal and caused by the radiation used during sterilization. Cassette Outlet Connect pump tubing here. Blue Outlet Plug Remove during sampling and replace immediately after sampling. WARNING! Do not open the blue inlet cap assembly! The substances used inside may be irritating to your skin. 7

8 SAMPLE PREPARATION - CALIBRATION The Via-Cell sampler requires the sampling pump to be calibrated at a flow rate of 15 liters per minute to ensure proper collection. Ideally, calibration should be checked prior to and after each collection and as a minimum once per day. It is strongly recommended that a primary standard device such as a soap bubble meter/tube or other NIST certifiable device be be used to calibrate the sampling pump. Secondary calibration devices such as a rotameter may be used if it is calibrated against a primary standard. Below are examples of typical devices that can be used for calibration: Zefon Bio-Pump Primary Calibrators Zefon Via-Cell /Air-O-Cell CSI Bubble Tube minibuck IAQ Calibrator Secondary Calibrators Zefon Via-Cell /Air-O-Cell CSI Flowmeter (#ZBP-305) High Volume Pumps (includes AC powered rotary vane, diaphragm and linear pumps) Primary Calibrators Gilian Gilibrator Electronic Bubble Meter minibuck IAQ Electronic Calibrator Secondary Calibrators Rotameter flow meters Bios DryCal Electronic Calibrator Please note that some pumps, including the battery powered Zefon Bio-Pump, will only work with specific calibration devices. Please reference the operation manual for your pump to determine if special calibration devices are needed. 8

9 Typical Bio-Pump Calibration Setup Via-Cell /Air-O-Cell CSI Flowmeter mini-buck IAQ Calibrator Via-Cell /Air-O-Cell CSI Bubble Tube The Via-Cell flowmeter used with the Zefon Bio-Pump has the in-line resistance of a sampler built into the calibration scale. When using the mini-buck or Via-Cell/ Air-O-Cell CSI bubble tube, actual samplers are used in-line during calibration. For complete calibration instructions, please refer to the instructions included with your pump or calibration device. Typical High Volume Pump Calibration Setup Direct Connection to Electronic Calibrator Direct Connection to Rotameter Flowmeter In-Line Connection to Electronic Calibrator The Via-Cell sampling cassette does not produce significantly measurable backpressure and does not impede the performance of most high volume rotary vane, diaphragm or linear pumps. Therfore the calibration device may optionally be connected directly to the pump (without a Via-Cell sampling cassette in line) to calibrate the pump flow rate. When choosing to calibrate with a sampler in-line, it is recommended that one sampler is retained as a permanent calibration cassette and used for this purpose each time. 9

10 COLLECTING A SAMPLE 1. Calibrate the sampling pump to a flow rate of 15 lpm. 2. Clean hands or wear clean, disposable, powder free gloves. 3. Tear open the foil package using the tear strip on top. Use care when opening as this package is re-sealable and is required to be used after sampling for transport to the laboratory. 4. Remove the Via-Cell from the package. 5. Remove the blue inlet cap and record the Via-Cell serial number, along with any other pertinent information on the front of the foil package. The serial number can be viewed through the top of the cassette once the blue inlet cap is removed. It is printed directly on the collection slide as shown in Figure 4. After recording the serial number, replace the blue inlet cap until ready to sample. 6. Remove the blue outlet plug from the cassette and place the plug into the foil pouch for safe keeping. Figure 4 10

11 ABOUT THE FOIL PACKAGING It is important to retain the resealable foil package for transportation of the cassette to the laboratory. This package along with the blue inlet and outlet caps combine to control the environmental conditions inside the cassette after sample collection. This is critical in maintaining the viability of the particles if culture analysis is required. The included safety seal label is used to ensure your collected sample remains uncontaminated until it reaches the laboratory. CAUTION The interior of the Via-Cell sampler is sterile. Care needs to be taken when handling the product with the plugs removed so that the sampling port and outlet port do not become contaminated with materials that may alter the collection or analysis of the sample (e.g. introduce materials not normally collected in the air stream). 7. Connect the Via-Cell sampler to the pump and position the cassette in the desired location. The Via-Cell sampler is capable of operating in any vertical or horizontal orientation and in confined spaces such as ducts, plenums or wall cavities. 8. Remove the large blue inlet cap from the cassette and place into the foil package for safekeeping. 9. Turn on the pump and run for the desired amount of time. Reference the chart on page 12 for assistance in determining the correct sampling time. 10. When the sampling period is completed replace the blue plug in the outlet and the blue cap over the inlet. Handle these items by the outer finger grips. The plugs will prevent contamination of the interior of the cassette during transport, and ensure proper environmental conditions of the collected sample. 11. Place the Via-Cell sampler into the special foil bag and zip it closed. Apply the red safety seal label over the top of the foil bag opening. This will ensure the integrity of your sample until it reaches the laboratory. Note the sample time and other important sampling information. Send the cassette to the analysis laboratory to arrive within 24 hours after the sample was collected. Refrigeration of the collected sample is not required during transport. 11

12 SAMPLING TIME RECOMMENDATIONS The Via-Cell sampler collection period is dependent upon the density of the particulate in the environment. When sampling in a dusty environment, the particles can overlay each other on the slide causing difficulties in direct microscopy analysis. In addition particles will not adhere to the adhesive media if the adhesive is already covered by particles. The following chart suggests typical sampling times to attain a particle deposition on the slide in which the edges of the trace are sharply defined and the particles dispersed properly to enable good microscopic evaluation. Longer/shorter collection times may be required. Each situation must be evaluated according to specific conditions and the Via-Cell sampler sampling time must be adjusted to meet those conditions. RECOMMENDED SAMPLING TIMES Environmental Dust Conditions Clean office environment or outdoors (no visible dust) Indoor environment, high activity Indoor environment, evidence of drywall renovation or industrial dust Sampling Time 10 minutes 5 minutes 1 minute CONTROL SAMPLE RECOMMENDATIONS Using one or more of the following control sample recommendations is considered a good sampling practice that will help provide some basic guidelines to interpreting results: 1. Collection of an outdoor sample may help to determine the amplification of indoor particles. 2. Collection of a sample in a non-suspected area may assist with the comparison of results. This can also sometimes be used in place of an outdoor sample when conditions outside are not favorable for sampling, such as on a rainy day. 3. Field blanks are a recommended sampling procedure. 12

13 LABORATORY ANALYSIS STRATEGIES The Via-Cell sampler is unique in that the particulate collected may be analyzed using one or more analytical methods such as culturing, microscopy, PCR (polymerase chain reaction), or other types of analysis. Because the media on the Via-Cell slide is water soluble, and the lower half of the sampling cassette has a built-in trough, the sample collection may be suspended in water directly in the cassette without additional glassware. This suspension can then be transferred and used in any number of analytical methods that can use this suspension. NOTE Aseptic (sterile) handling procedures must be employed by laboratory personnel to prevent the introduction contamination that could affect analysis. The collected sample must be processed in the laboratory in a timely manner. Experimentally it has been shown that collected mold particles (for example, Cladosporium cladosporioide) can maintain viability inside the Via-Cell up to 5 days after collection. However, the best viability and resulting growth was achieved within 3 days. After 3 days, some diminished viability will occur. For this reason it is recommended that the collected sample reach the laboratory within 24 hours after collection and that the sample should be processed by the laboratory within 24 hours after receipt. Processing may include screening, creation of the suspension and culture. If analysis as PCR is done, the collection can remain on the collection slide much longer as viability of the particles is not a factor. Please note that if culturing of the collection is anticipated, staining of the collection will not be possible for prescreening the particles with direct microscopy since stain kills the viable particles. If PCR analysis is anticipated, staining may be possible; it will be up to the user to determine the suitability of the stain and possible interference with the analysis. NOTICE Each Via-Cell sampler should have a plug installed into the outlet port of the cassette as well as the cap over the inlet port when received by the laboratory. These are necessary to seal the cassette to control the environmental conditions as well as prevent contamination during shipment. The outlet plug will seal the bottom of the cassette so water can be added to dissolve the media and suspend the particles. If the user did not re-install the plugs after collection, the ability of the mold particles to be grown may be compromised. 13

14 SAMPLE PREPARATION FOR CULTURING OR PCR The Via-Cell sampler can be prepared for culturing, PCR and other analysis by suspending the particles in sterile water, then dispensing the suspended particles onto agar plates or other media. Required Supplies -Syringe - 3cc sterile, or sterile pipettes -Sterile water -Culture plates with appropriate agar -Sterile particle spreaders -Self-closing tweezers -Controlled environmental chamber 1. Verify that the plug and cap are installed in the cassette. Record the sampler serial number onto the lab worksheet. The serial number is printed directly on the slide, not on the outside of the cassette. 2. Clean the outer surface of the sampler to remove any excess dirt. Cut the protective tape. Open the cassette in the controlled environmental chamber, keeping the slide in position as shown below. Be careful not to get pieces of tape inside the sterile cassette. 3. The collection slide will be facing media-side down toward the V shaped inlet sampling port. When you can read the word ZEFON on the collection slide, the media will be facing you. Collection Slide Media side faces the slit opening (the media is facing down in this picture) Trough in bottom half of cassette 14

15 4. Put 2cc sterile water into the trough in the bottom half of the cassette. After cleaning the tweezers tip with alcohol, place the slide upside down (media side down) on top of the water. If any large bubbles are trapped under the slide, gently lift one side of the slide and slowly lower to remove bubbles. NOTE: Be sure the alcohol has completely dried before handling the slide. 5. Leave the slide exposed to water for a minimum of 5 minutes 6. After 5 minutes, raise the slide with the forceps and flush the face of the slide with 1/4 cc of sterile water. Allow water to fall into cassette. If the adhesive does not completely wash off the slide, let the slide sit an additional 5 minutes to dissolve the remaining adhesive. 7. Draw the suspension from the cassette housing into a sterile syringe or pipette, then dispense onto a culture plate. Culture Plating Tip It may be desirable to split the suspension onto several culture plates. Particles such as molds and funguses germinate in less than 100% RH (liquid water). Using more water to dissolve the media may result in a longer time for the water to evaporate from the surface of a culture plate and growth to occur. 15

16 DIRECT MICROSCOPY PROCEDURES General This procedure will enable the analyst to overview the particles on the slide and then determine the next course of action to take (e.g. culture the sample). If culturing the sample after microscopic analysis is a possibility, it is important to aseptically handle the slide with sterile instruments to maintain sterility of both the slide and the inside of the cassette. Analysis of the collected sample should be performed by those experienced in particle identification. Required Supplies -Standard 1 x 3 microscope slide -Microscope -Stain or linking solution (see stain notice below) -Self-closing forceps -Controlled environmental chamber -Zefon Via-Cell Sterile Microscopy Linking Solution -Cover Glass Sample Preparation 1. Prepare a standard microscope slide by sterilizing with alcohol. 2. Record the Via-Cell sampler serial number onto the lab worksheet. 3. Cut the adhesive label around the Via-Cell cassette. 4. Aseptically open the cassette in the environmental chamber taking care not to touch the inner surfaces of the cassette. 5. Remove the slide using forceps (tips sterilized with alcohol) and place onto the sterilized microscope slide with the media side up (when the media is facing up, you can read the printing on the slide). DO NOT place the Via-Cell slide face down onto the microscope slide as transfer of the adhesive and/or particles may occur. 6. Place the slide under the microscope for examination. Be careful not to contaminate the slide. NOTICE Stains such as LactoPhenol Cotton Blue or Saffron Red contain solvents that will destroy the ability for spores to grow. DO NOT use any type of stain if you plan to culture the sample after examination 16

17 DIRECT MICROSCOPY SLIDE PREPARATION For use when standard direct microscopy is required and the sample may later be cultured. A NOTE ABOUT LINKING SOLUTION The use and application of linking solution is an important step when examining Via-Cell slides under direct microscopy and/or when viability of particles needs to be preserved. The adhesive on the Via-Cell slide has a frosty appearance in its natural form. This needs to be cleared before use in direct microscopy. Use of linking solution solves this. The linking solution works by partially dissolving the adhesive. Therefore it is necessary to place enough solution onto the slide that will allow the cover slip to carry the solution completely under the cover slip. Otherwise blotchy, non-clarified areas may be seen under the cover slip. Step 1 Place the Via-Cell slide onto the microscope slide media side up. IMPORTANT: Do not permanently mount sample to microscope slide. This preserves the ability to culture the sample. slide with media facing up Sterile Microscope Slide IMPORTANT! Application of the linking solution must be done very carefully and in a specific manner to avoid disturbing the collected sample trace. Please follow the directions regarding proper application of linking solution precisely. 17

18 Step 2 Place a generous amount of linking solution along the edge of the slide. DO NOT place drops of linking solution directly on the trace area. This will result in excessive disturbance and shifting of particles. Step 3 Lower the cover slip on top of the slide gently at an angle as shown. Placing the cover slip on the slide this way allows the linking solution to spread across the slide while disturbing the trace as little as possible. 18

19 Preparation is now complete Slides take several minutes to clear. Here is an example of a before and after look at the slide. Your slide should exhibit clarity similar to the top example. Direct Microscopy Preparation Application Notes: 1. Always sterilize a cover glass to place over the collection if you intend to later culture the sample. 2. Sterilization is not necessary if you do not intend to culture the sample. 3. Use of any type of stain or solvent should only be used if you do not intend to culture the sample. Some stains may not clear the Via-Cell slide adequately. If this happens, contact Zefon and we can provide guidance or sell a stain that will clear adequately. 4. If using immersion oil, apply it carefully. If immersion oil makes contact with the Via-Cell adhesive, it will probably result in killing any viable particles. 5. Always rinse the cover glass with about 1/4cc water into the cassette trough to collect any particles that have adhered to it. 19

20 Estimation of Collected Particle Load Direct microscopy enables the analyst to estimate the concentration of particles in the sampled area. Counting and quantification of the collected particles accomplish this. This estimation is conducted by counting calibrated cross-sections of the deposited sample trace. The number and type of particles estimated per cubic meter of air is calculated based on the a) length of the deposition trace, b) length of trace actually examined, c) volume of air collected, and d) number of particles counted. The Via-Cell Sampler particle deposition area is approximately 0.9 mm wide by 14.4mm long yielding an approximate area of mm 2. The width of the deposition trace may vary slightly in particle density from the middle to outer edges of deposition. For this reason, using the deposition trace area is not recommended for direct calculation of particle concentrations. The recommended procedure for calculating particle concentrations is based on using the Via-Cell Sampler trace length and microscope field diameter. One field of view counted is defined as the calibrated diameter of the microscope field of view (in mm) covering one cross-sectional pass or traverse across the sample deposition trace. A typical sample preparation and microscopic counting procedure is illustrated in Figure 5. Figure 5 ILLUSTRATION OF THE COUNTING PROCEDURE Microscope slide slide Analysis starts at 1st traverse - completes and moves to 2nd traverse Sample particulate 20

21 The calculation of particle concentration per cubic meter of air can be performed by using the following equations: Determine the actual air volume collected in cubic meters (m 3 ) using the following calculation: Determine the length of sample trace counted based on the microscope field of view and number of fields of view counted. It will be necessary to accurately calibrate and measure the diameter of the microscope field of view using a stage micrometer slide. Remember, each microscope is different, and each different combination of ocular and objective lens must be calibrated separately. Stated lens magnifications are rarely precise. The microscopist should then record the number of complete traverses examined across the width of the deposition trace and use the formula given below to calculate the actual length of the deposition trace examined. The concentrations of particles (cts/m 3 ) can then be determined by using the equation below. 21

22 Mold Spore Example Calculation Microscope field diameter at (900X) = mm Number of traverses = 10 Sample volume (15 minutes) = (15 / 1000) x 10 = 0.150m 3 Mold spore counts = 50 MICROSCOPIC COUNTING RECOMMENDATIONS Particle Type Pollen Counting Recommendation Entire trace or 100 grains (whichever comes first) should be examined at a minimum magnification of 200X. Identification and speciation should be performed at minimum magnification of 400X. Mold Spores A minimum of 15% of the entire trace should be examined or a minimum of 100 mold spores counted (whichever comes first). Identification and speciation should be performed at minimum magnification of 400X. Fibers The entire trace or 100 fibers, (whichever comes first) should be examined at a minimum magnification of 200X. Other Aerosols Skin cell fragments, combustion emissions, insect parts A minimum of 10% of the entire trace should be examined or a minimum of 100 particles counted (whichever comes first).

23 Product Number VIA010 AOCCAL AOC-WS10 Z-LITE-IAQ Ordering Information Field Equipment Description Via-Cell Cassettes, 10/pk Via-Cell In-Line Calibration Adapter Via-Cell Inner Wall Sampling Adapter Zefon Z-Lite IAQ Pump ZBP-200 Zefon Bio-Pump ZBP-311 APB DCL-H ZBP-305 Zefon Bio-Pump Via-Cell/Air-O-Cell CSI Bubble Tube mini-buck IAQ Calibrator Bios DryCal DC-Lite Calibrator Via-Cell/Air-O-Cell CSI Flow Indicator Laboratory Equipment Product Number ZA0046 ZA0050 ZA0051 ZA0052 ZA0054 ZA0055 ZA0056 ZA0058 Description Cassette Opener Particle Spreader, T shaped, sterile Syringe, sterile, 3cc Alcohol wipes, 200/bx Forceps, self closing, each Water, sterile, 100cc, screw cap container Via-Cell Linking Solution Via-Cell Blue Stain

24 5350 SW 1st Lane, Ocala, FL Phone: Fax: Fax: Copyright 2000 Zefon International, Inc. Via-Cell, Air-O-Cell, and BioPump are registered trademarks of Zefon International.

ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION. (Analysis Code: FDE)

ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION. (Analysis Code: FDE) Expert Services in Environmental Microbiology Report Supporting Document ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION (Analysis Code: FDE) INTRODUCTION Fungi are

More information

Aseptic Techniques. A. Objectives. B. Before coming to lab

Aseptic Techniques. A. Objectives. B. Before coming to lab Aseptic Techniques A. Objectives Become familiar with 1. The ubiquity of microorganisms (see Note 1) 2. Aseptic techniques (see Note 2) 3. Standard methods for growing/observing microorganisms (see Note

More information

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure *Polymerase Chain Reaction is covered by patents owned by Hoffmann-La Roche, Inc. This experiment was adapted from Laboratory

More information

Principles and Practice of Agarose Gel Electrophoresis

Principles and Practice of Agarose Gel Electrophoresis Edvo-Kit #101 Principles and Practice of Agarose Gel Electrophoresis Experiment Objective: The objective of this experiment is to develop a basic understanding of electrophoretic theory, and to gain "hands-on"

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Water Sampler # 15010 OPERATING INSTRUCTIONS Purpose: Contents: For the collection of water samples at varying depths or distances away from a shoreline. One (1) Assembled Water Sampler One (1) Cord (15

More information

Premise Microbial Testing

Premise Microbial Testing Premise Microbial Testing Basic IAQ Microbial Sampling Methods Jason Dobranic, Ph.D. Vice President of Microbiology & Life Sciences Sampling Guidelines Sampling alone is far from foolproof Visual inspection,

More information

Guidelines for QualiTru Line Sampling

Guidelines for QualiTru Line Sampling Guidelines for QualiTru Line Sampling QUALITRU GUIDELINES FOR LINE SAMPLING 1. Purpose: Following these Standard Operating Procedures, farms and processing plants may use the QualiTru aseptic sampling

More information

PLP 6404 Epidemiology of Plant Diseases Spring 2015 LAB 2 PHASES IN THE DISEASE CYCLE: GREENHOUSE AND LAB EXERCISE

PLP 6404 Epidemiology of Plant Diseases Spring 2015 LAB 2 PHASES IN THE DISEASE CYCLE: GREENHOUSE AND LAB EXERCISE PLP 6404 Epidemiology of Plant Diseases Spring 2015 LAB 2 PHASES IN THE DISEASE CYCLE: GREENHOUSE AND LAB EXERCISE "Variation in Host-Pathogen Interactions and its Effect on Epidemic Development" Purpose:

More information

SEB Autoclave Training

SEB Autoclave Training SEB Autoclave Training 1 Autoclave Details 3 Autoclaves located in SEB, one on each upper floor. Expensive pieces of equipment ($70,000 each). Essential for several groups research. Most malfunctions are

More information

Exercise 19. Fungi: Molds and Yeasts F10 Or The Rotten World Around Us

Exercise 19. Fungi: Molds and Yeasts F10 Or The Rotten World Around Us Exercise 19 119 Fungi: Molds and Yeasts F10 Or The Rotten World Around Us INTRODUCTION: Student Learning Objectives: After completing this exercise students will: a. Define the terms Saprophyte, Mycosis,

More information

INTRODUCTION TO THE PROGRAM

INTRODUCTION TO THE PROGRAM INTRODUCTION TO THE PROGRAM Structure and Organization Information in this program is presented in a definite order, so that employees will see the relationships between the various groups of information

More information

Neural Stem Cells (ipsc from Blood Cells; Male)

Neural Stem Cells (ipsc from Blood Cells; Male) Applied StemCell, Inc. (866) 497-4180 www.appliedstemcell.com Datasheet Neural Stem Cells (ipsc from Blood Cells; Male) Product Information Catalog Number ASE-9234 (Male) Description Applied StemCell's

More information

2. Be sure to wear gloves and safety goggles, especially when using the disinfectant.

2. Be sure to wear gloves and safety goggles, especially when using the disinfectant. Mold Control INTRODUCTION In this activity, your class will test three different cleaners and then will determine which cleaner is most effective for controlling mold. You will analyze a series of dilutions

More information

4. The Second-dimensional SDS-PAGE (vertical) Protocol

4. The Second-dimensional SDS-PAGE (vertical) Protocol 4. The Second-dimensional SDS-PAGE (vertical) Protocol I. PURPOSE This procedure outlines the steps that must be carried out in the seconddimension SDS-PAGE using vertical system. II. ENVIRONMENT All work

More information

Revised 27 Aug rm (Vers. 4.1)

Revised 27 Aug rm (Vers. 4.1) Please use only the valid version of the package insert provided with the kit. INTENDED USE Vitamin Folic Acid Test is a microtiter plate test kit based on a microbiological assay which measures the total

More information

MicroFunnel Filter Funnels

MicroFunnel Filter Funnels MicroFunnel Filter Funnels Description Increase laboratory efficiency with a newly designed, disposable filter funnel and Petri dish all in one. Certified. Each lot is certified for microbiological analysis

More information

Experiment 3: The Chromatography of Organic Compounds

Experiment 3: The Chromatography of Organic Compounds Experiment 3: The Chromatography of Organic Compounds INTRODUCTION Very often, in an organic synthesis, a reaction will proceed to produce multiple products or perhaps will only partially form the desired

More information

Experiment 2: The Chromatography of Organic Compounds

Experiment 2: The Chromatography of Organic Compounds Experiment 2: The Chromatography of Organic Compounds INTRODUCTION When performing an organic reaction, it is very common to observe the formation of other compounds in addition to your desired product;

More information

Method Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. EPA/600/R-10/181 December 2010

Method Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. EPA/600/R-10/181 December 2010 EPA/600/R-10/181 December 2010 www.epa.gov/ord Method 1615 Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR Office of Research and Development National Exposure Research

More information

Electron Microscopy (EM) Grid

Electron Microscopy (EM) Grid Anirban Som 25-01-14 Instrumental technique presentation Electron Microscopy (EM) Grid What I will talk about Some basic topics about EM grid Home-made grid preparation Grid cleaning Carbon coating and

More information

I-STAT POCT System PRINCIPLE:

I-STAT POCT System PRINCIPLE: PRINCIPLE: I-STAT POCT System The i-stat system uses a single disposable cartridge. The cartridge, which has been filled with fresh blood, is placed into a hand-held analyzer for analysis. The results

More information

Critical Environment Products and Services

Critical Environment Products and Services Critical Environment Products and Services For over two decades, EP Scientific products and services have defined clean for environmental sampling containers and services. Our proprietary cleaning methods

More information

TWO-DIMENSIONAL GEL ELECTROPHORESIS THE FIRST DIMENSION

TWO-DIMENSIONAL GEL ELECTROPHORESIS THE FIRST DIMENSION TWO-DIMENSIONAL GEL ELECTROPHORESIS THE FIRST DIMENSION This procedure has been developed for the Hoefer DE 102 series tube gel electrophoresis apparatus, which can run up to 12 tube gels at a time. The

More information

Comprehensive Procedures for Collecting Environmental Samples for Culturing Bacillus anthracis Revised April 2002

Comprehensive Procedures for Collecting Environmental Samples for Culturing Bacillus anthracis Revised April 2002 Comprehensive Procedures for Collecting Environmental Samples for Culturing Bacillus anthracis Preface Environmental sampling to determine the presence of Bacillus anthracis spores in indoor environments

More information

RAC. Interpretation Guide. Rapid Aerobic Count Plate

RAC. Interpretation Guide. Rapid Aerobic Count Plate Interpretation Guide The 3M Petrifilm is a sample-ready-culture medium system which contains nutrients, a cold-water-soluble gelling agent and a dual-sensing indicator technology that facilitates aerobic

More information

CORNER ELEMENTS CENTRE SUPPORT ACCESSORY BAG PROJECTION SCREEN BAG. 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional)

CORNER ELEMENTS CENTRE SUPPORT ACCESSORY BAG PROJECTION SCREEN BAG. 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional) FULLWHITE MANUAL CORNER ELEMENTS 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional) CENTRE SUPPORT Consists of plug in elements with integrated screw connection ACCESSORY BAG Yellow

More information

Rev. 07 8/15 Please Read Disclaimers:

Rev. 07 8/15 Please Read Disclaimers: FiberCorr panels Guidelines 6005.FC Rev. 07 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to help prevent any problems

More information

ATT-42/95 SAMPLING, Asphalt

ATT-42/95 SAMPLING, Asphalt 1.0 Scope ATT-42/95 SAMPLING, Asphalt 1.0 SCOPE This method describes the procedures for obtaining representatives samples of asphalt, crack sealer and crack sealing materials. 2.0 EQUIPMENT The following

More information

Bacterial Counts - Quantitative Analysis of Microbes

Bacterial Counts - Quantitative Analysis of Microbes Bacterial Counts - Quantitative Analysis of Microbes Introduction: It is often important to know not only what types of bacteria are in a sample but also how many of them are present. Food manufacturers

More information

Preparation thin blood films and Giemsa staining

Preparation thin blood films and Giemsa staining TLM_PRO_026 Version No.001 Page 1 of 5 Department: Clinical sciences Unit: Tropical Laboratory Medicine Preparation thin blood films and Giemsa staining Project/study: Not applicable 1. Scope and application

More information

"ASBESTOS AWARENESS IN THE WORKPLACE"

ASBESTOS AWARENESS IN THE WORKPLACE MAJOR PROGRAM POINTS "ASBESTOS AWARENESS IN THE WORKPLACE" Training For THE OSHA ASBESTOS STANDARD Quality Safety and Health Products, for Today...and Tomorrow Outline of Major Points Covered in the "Asbestos

More information

Optima Vector Plank. Installation Instructions. Ceiling

Optima Vector Plank. Installation Instructions. Ceiling Ceiling Systems Between us, ideas become reality Optima Vector Plank Installation Instructions 1. GENERAL 1.1. Product Description The Vector products referenced in these instructions are made from fiberglass.

More information

Human IL-1 alpha ELISA Kit

Human IL-1 alpha ELISA Kit Human IL-1 alpha ELISA Kit Catalog No: CDK025B Quantity: 2 x 96 tests SPECIFICITY : RANGE : SENSITIVITY : INCUBATION : SAMPLE TYPES : Recognizes both natural and recombinant human IL-1 alpha 31.2 pg /

More information

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS DEPARTMENT OF VETERANS AFFAIRS Veterans Health Administration Washington DC 20420 IL 10-2006-008 In Reply Refer To: 10NB UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL

More information

LAB 6: Agarose Gel Electrophoresis of Restriction Digested Plasmid DNA

LAB 6: Agarose Gel Electrophoresis of Restriction Digested Plasmid DNA LAB 6: Agarose Gel Electrophoresis of Restriction Digested Plasmid DNA I. Objectives The purpose of today s lab is to learn how to set up and run an agarose gel, separate DNA fragments on the gel, and

More information

User Guide BLF-7510 BUF High-Pass TM DNA Size Selection. Sage Science Part Nos:

User Guide BLF-7510 BUF High-Pass TM DNA Size Selection. Sage Science Part Nos: TM User Guide High-Pass TM DNA Size Selection Sage Science Part Nos: BLF-7510 BUF-7510 Sage Science, Inc. Suite 2400 500 Cummings Center Beverly, MA 01915 Using this Guide This guide is meant to provide

More information

STANDARD OPERATING PROCEDURES

STANDARD OPERATING PROCEDURES PAGE: 1 of 14 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY* 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS* 6.0 REAGENTS

More information

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC Equipment and Caulking Installations Instructions Using Caulking Applicator Guns There are different types of caulking applicator guns available. The recommended procedure when using the different styles

More information

Human IL-6 ELISA Set

Human IL-6 ELISA Set Human IL-6 ELISA Set Catalog No. CDK082B Quantity: 10 x 96 tests PRODUCT SPECIFICATIONS : Specificity: Recognizes both natural and recombinant human IL-6 Range: 6.25 pg / ml - 200 pg / ml Sensitivity:

More information

Liquid layer sampler, cable operated

Liquid layer sampler, cable operated Liquid layer sampler, cable operated operating instructions Contents On these operating instructions...2 1. Description...2 2. Taking into operation and decontamination...3 3. Using the device...4 3.1

More information

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm Document: AND016 04 2014 Cadmium Testing and On Site Calibration for Water Testing Detection Range: 0.1 1.0ppm April, 2014 Edition 3 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of

More information

Destructible Vinyl Label Material 7613T / 7930T

Destructible Vinyl Label Material 7613T / 7930T Destructible Vinyl Label Material Technical Data May 2017 Product Description 3M Destructible Vinyl Label Materials 7613T and 7930T are consistent, smooth, topcoated films designed to exhibit immediate

More information

Destructible Vinyl Label Material

Destructible Vinyl Label Material Tech 7613 Destructible Vinyl Label Material Technical Data Product Description Destructible Vinyl Label Material 7613 is a consistent, smooth, topcoated film designed to exhibit immediate destructibility

More information

Water-Water Titration for the MicroCal ITC200

Water-Water Titration for the MicroCal ITC200 Water-Water Titration for the MicroCal ITC200 Goal: Water-Water titrations are a good way to check for possible problems, especially the cleanliness of the ITC and your skills in cell filling. If a water-water

More information

PS-101 Preparing for Your Success

PS-101 Preparing for Your Success PS-101 Preparing for Your Success The Pressure-sensitive Label Construction Module 4: Adhesives Pressure-Sensitive Adhesive Features Coating Technology Adhesive Chemistry Adhesive Selection Criteria &

More information

TRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE

TRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE TRANSFER OF BACTERIA USING ASEPTIC TECHNIQUE GENERAL GUIDELINES: Safety Wear a lab coat and have your goggles on! ALWAYS disinfect the tables BEFORE and AFTER lab. Wash your hands with soap both BEFORE

More information

OLM Environmental, LLC PHONE: (919) LOCKWOOD FOLLY LANE; RALEIGH, NC CELLPHONE: (919)

OLM Environmental, LLC PHONE: (919) LOCKWOOD FOLLY LANE; RALEIGH, NC CELLPHONE: (919) OLM Environmental, LLC PHONE: (919) 212-3019 2317 LOCKWOOD FOLLY LANE; RALEIGH, NC 27610 CELLPHONE: (919) 931-0629 July 31, 2016 Zapolski Real Estate, LLC 501 Washington Street Durham, North Carolina 27701

More information

Ultrahydrogel Columns

Ultrahydrogel Columns CONTENTS I. INTRODUCTION II. INSTALLATION a. Solvents b. Column c. Organic solvents d. Aqueous salt and buffer solution e. Flow rate f. Solvent and sample preparation g. Guard columns h. Column installation

More information

IN-TANK TECHNOLOGY INSTRUCTIONS FOR USING FLO KING IN-TANK CARBON BAG

IN-TANK TECHNOLOGY INSTRUCTIONS FOR USING FLO KING IN-TANK CARBON BAG Carbon Bag Instructions Page 1 INSTRUCTIONS FOR USING FLO KING IN-TANK CARBON BAG Do not attempt to carbon treat a solution before you have thoroughly filtered it! This almost certainly will result in

More information

The Professionals Choice for Air Sampling Equipment

The Professionals Choice for Air Sampling Equipment The Professionals Choice for Air Sampling Equipment The NRD finally gives us a personal sampler to measure risk assessment on a nanoparticle scale. There s nothing else out there like it. Bioaerosol &

More information

Bovine IgG ELISA Kit

Bovine IgG ELISA Kit Bovine IgG ELISA Kit Cat. No. E11-118 Components Supplied Bovine IgG Pre-Coated 96-well Strip Plate, 1 each Bovine IgG Standard, 500 ng/vial, 2 each Bovine IgG Detection Antibody, 12 ml 20X Dilution Buffer

More information

ph AND REFERENCE ELECTRODE USER MANUAL

ph AND REFERENCE ELECTRODE USER MANUAL ph AND REFERENCE ELECTRODE USER MANUAL 1 1 ph and reference electrode manual Copyright 2014 Unisense A/S Version December 2014 ph AND REFERENCE ELECTRODE MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY

More information

To whom it may concern, February 21, 2011

To whom it may concern, February 21, 2011 To whom it may concern, February 21, 2011 The following is an evaluation of the GEMS grant that I received to start my own C-MORE lab kits, specifically ocean acidification, plankton, marine debris and

More information

Reference Only. 2.Part Numbering (ex) NF Z 5B BW 2R9 L N 1 0 L

Reference Only. 2.Part Numbering (ex) NF Z 5B BW 2R9 L N 1 0 L SpecNo.JENF243J-0011A-01 P1/10 CHIP NOISE FILTER NFZ5BBW LN10 REFERENCE SPECIFICATION 1.Scope This reference specification applies to NFZ5BBW_LN10L Series, Chip Noise Filter. 2.Part Numbering (ex) NF Z

More information

General Specifications for HVAC System Cleaning

General Specifications for HVAC System Cleaning General Specifications for HVAC System Cleaning Part 1 Special Provisions 1.01 Qualification of the HVAC System Cleaning Contractor (A) Membership: The HVAC system cleaning contractor shall be a member

More information

Human Myostatin, ELISA Kit (MSTN)

Human Myostatin, ELISA Kit (MSTN) Human Myostatin, ELISA Kit (MSTN) 96 Tests Catalog Number: MBS733837 Store all reagents at 2-8 C Valid Period: six months For samples: Cell culture fluid & body fluid & tissue homogenate Serum or blood

More information

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

PORTABLE ph METER PRICE CODE NUMBER MODEL 100 PORTABLE METER MODEL 100 PRICE CODE NUMBER 56-0032 Refer to Bulletin A-301. OPERATION AND SERVICE GUIDE O-670A DEC. 1997 GENERAL INFORMATION Model 100 meter is designed for measuring over the entire 0

More information

CASY Model TT E L E C T R I C A L C U R R E N T EXCLUSION ECE BASED CELL ANALYSIS

CASY Model TT E L E C T R I C A L C U R R E N T EXCLUSION ECE BASED CELL ANALYSIS CASY Model TT Cell Counter + AnalyZer E L E C T R I C A L C U R R E N T EXCLUSION ECE BASED CELL ANALYSIS ELECTRICAL CURRENT EXCLUSION CASY Model TT Cell Counter + Analyzer R&D Easy and fast adaptation

More information

One such problem is blood residual inside the channels of a robotic arm.

One such problem is blood residual inside the channels of a robotic arm. SUBJECT: Robotic Arm Testing for residue blood DEPARTMENT: Central Service APPROVED BY: EFFECTIVE: REVISED: 07/2016 PURPOSE: To test for detection of blood residue inside and outside of a robotic arm and

More information

Genome Edited ipscs APOE -/- Knockout

Genome Edited ipscs APOE -/- Knockout Applied StemCell, Inc. (866) 497-4180 www.appliedstemcell.com Datasheet Genome Edited ipscs APOE -/- Knockout Product Information Catalog Number Description Amount Parental Cell Line Gene Knockout Generated

More information

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the 312 METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g., sampling) essential

More information

Fumigation Operations

Fumigation Operations Kentucky Pesticide Education Program copyright 2016 University of Kentucky Department of Entomology Structural Fumigation Fumigation Operations Structural fumigation (photo: sanjoaquinpestcontrol.com)

More information

FLUID CLEANLINESS OIL FILTRATION

FLUID CLEANLINESS OIL FILTRATION FLUID CLEANLINESS c o m p a r i s o n g u i d e Companion Booklet to be used with The Portable Fluid Analysis Kit A Companion Booklet to be used with The Portable Fluid Analysis Kit OIL FILTRATION TM SYSTEMS,

More information

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime EASY-Spray Columns Guidance for column set up and installation Tips to maximize column lifetime EASY-Spray Column Tips and Tricks This document provides guidance for Thermo Scientific EASY-Spray column

More information

2 ADAPTER MOUNTING & APPLICATION

2 ADAPTER MOUNTING & APPLICATION 2 ADAPTER MOUNTING & APPLICATION TABLE OF CONTENT 2 ADAPTER MOUNTING & APPLICATION 1. 7 MEASURING A 100 ML SOIL SAMPLE WITH KSAT AND ADDITIONAL HYPROP 1.1 9 SATURATING THE SOIL SAMPLE FOR KSAT MEASUREMENTS

More information

Lambda (λ) DNA Restriction Digest and Electrophoresis Lab

Lambda (λ) DNA Restriction Digest and Electrophoresis Lab Lambda (λ) DNA Restriction Digest and Electrophoresis Lab Procedure DAY ONE: restriction digestion Today we will be exposing the lambda DNA to restriction enzymes. For background knowledge, make sure you

More information

Activity 5.1.4: Gram Staining

Activity 5.1.4: Gram Staining Activity 5.1.4: Gram Staining Introduction In the last activity, you isolated the bacteria that was responsible for Anna s illness and performed a gross examination of the resultant colonies. While gross

More information

10 Steps to Save Energy in Your House

10 Steps to Save Energy in Your House 10 Steps to Save Energy in Your House Sealing and insulating your home is one of the most cost-effective ways to make your home more comfortable and energy efficient. You can do it yourself. In this chapter,

More information

W ater T alk. Field Corrosion Testing using Coupons

W ater T alk. Field Corrosion Testing using Coupons W ater T alk Field Corrosion Testing using Coupons Volume 12, Issue 1 April 2012 Most Cooling Water systems are continuously in use. Therefore it is rare to have access to inspect the actual system to

More information

ENVIRONMENTAL SAMPLING

ENVIRONMENTAL SAMPLING ENVIRONMENTAL SAMPLING 1. GENERAL. Collecting and analyzing samples provides numerical data that describe a particular situation. The ASHG shall direct sampling procedures. The sampling criteria shall

More information

Special Specimen Collection Procedures for Coagulation Testing

Special Specimen Collection Procedures for Coagulation Testing Special Specimen Collection Procedures for Coagulation Testing The accuracy of hemostasis testing depends upon the quality of the specimen submitted. Hemostasis specimens must be properly collected, labeled,

More information

LATRINE CONSTRUCTION SHELTER. Pour flush latrine 2. Pour flush micro septic tank 3. Initial investment, location, human resources 4.

LATRINE CONSTRUCTION SHELTER. Pour flush latrine 2. Pour flush micro septic tank 3. Initial investment, location, human resources 4. LATRINE CONSTRUCTION Pour flush latrine 2 Pour flush micro septic tank 3 Initial investment, location, human resources 4 Concrete rings 5 Box 6 Cover 7 Slab and ceramic pan 8 Ring mold 9 Structure and

More information

For in vitro Veterinary Diagnostics only. DNA Extraction and PCR Detection Kit for Pasteurella multocida.

For in vitro Veterinary Diagnostics only. DNA Extraction and PCR Detection Kit for Pasteurella multocida. For in vitro Veterinary Diagnostics only. DNA Extraction and PCR Detection Kit for Pasteurella multocida www.kylt.eu DIRECTION FOR USE Art. No. 31058 / 31059 Kylt Pasteurella multocida DNA Extraction and

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-59 MicroVac Portable Cleanroom Vacuum Cleaner Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave.

More information

COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV GL = ISO 9001 = Biomaterial Hemolytic Assay. Kit Insert

COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV GL = ISO 9001 = Biomaterial Hemolytic Assay. Kit Insert COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV GL = ISO 9001 = Biomaterial Hemolytic Assay Kit Insert Version: April 2017 Summary Hemolytic activity is a requirement to be tested for any blood

More information

STANDARD OPERATING PROCEDURE FOR THE COLLECTION OF CHEMICAL AND BIOLOGICAL AMBIENT WATER SAMPLES

STANDARD OPERATING PROCEDURE FOR THE COLLECTION OF CHEMICAL AND BIOLOGICAL AMBIENT WATER SAMPLES Page 1 of 17 STANDARD OPERATING PROCEDURE FOR THE COLLECTION OF CHEMICAL AND BIOLOGICAL AMBIENT WATER SAMPLES The Office of Environmental Measurement and Evaluation EPA New England - Region 1 11 Technology

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P. O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 E-mail : globalw@globalw.com WS700 Sampler 01-455

More information

Best Practices for Reprocessing Endoscopes

Best Practices for Reprocessing Endoscopes Best Practices for Reprocessing Endoscopes Reprocessing of Endoscopes Reprocessing Room Standards The resources referenced include: Canadian Standards Association Provincial Infectious Disease Advisory

More information

Gas Chromatography Assignment Chem 543/443

Gas Chromatography Assignment Chem 543/443 Gas Chromatography Assignment Chem 543/443 1. Introduction Capillary gas chromatography (GC) is one of the most popular analytical techniques used in today s research. Its popularity is mainly due to efficient

More information

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017 edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017 MATERIALS 1. Cellulose nitrate disposable filter funnels or other field-tested,

More information

REDOX AND REFERENCE ELECTRODE USER MANUAL

REDOX AND REFERENCE ELECTRODE USER MANUAL REDOX AND REFERENCE ELECTRODE USER MANUAL 1 Redox and reference electrode manual Copyright 2017 Unisense A/S Version June 2017 REDOX AND REFERENCE ELECTRODE MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY

More information

Electrophoresis 101 Student Worksheet

Electrophoresis 101 Student Worksheet 1 Electrophoresis 101 Student Worksheet Experiment Objective To develop an understanding of electrophoresis principles. To analyze results and to calculate the sizes of unknown charged molecules from given

More information

Acetone is flammable; refer to the manufacturer s instructions for complete safety information.

Acetone is flammable; refer to the manufacturer s instructions for complete safety information. Installing UPP FRP Entry Seals on Fiberglass Sumps Introduction This document is meant as an installation overview for UPP FRP entry seals with fiberglass sumps and should be used in conjunction with the

More information

Sample for use a Guide Revised IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E.

Sample for use a Guide Revised IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E. IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E. COLI IN WATER 1 IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E. COLI IN WATER

More information

Mouse Peptide YY (PYY) ELISA

Mouse Peptide YY (PYY) ELISA Mouse Peptide YY (PYY) ELISA For the quantitative determination of mouse PYY in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-58705 For Research Use Only. Not for use in diagnostic

More information

EXPERIMENT GENOMIC DNA ANALYSIS

EXPERIMENT GENOMIC DNA ANALYSIS EXPERIMENT GENOMIC DNA ANALYSIS Population diversity Studies We have 5 species of planarians (3 purchased from Carolina Biologicals, 2 obtained from the Levin lab) andmight have additional species found

More information

EPK- EasyTest Patch Test Kit Manual

EPK- EasyTest Patch Test Kit Manual EPK- EasyTest Patch Test Kit Manual The new Patch Test Kit from Schroeder provides the necessary tools to determine levels of both water and solid particulate contamination present in a particular fluid

More information

Installation Guide D-Shape

Installation Guide D-Shape Installation Guide D-Shape Thank you for selecting a DuctSox ventilation system. This guide should be helpful for installing Surface Mount Suspension Systems. Sections of fabric will be labeled, assembled,

More information

2015 CORNELL SOIL HEALTH TRAIN-THE-TRAINER WORKSHOP AUGUST 5-8, 2015 ITHACA, NY. Wet Aggregate Stability Test

2015 CORNELL SOIL HEALTH TRAIN-THE-TRAINER WORKSHOP AUGUST 5-8, 2015 ITHACA, NY. Wet Aggregate Stability Test 2015 CORNELL SOIL HEALTH TRAIN-THE-TRAINER WORKSHOP AUGUST 5-8, 2015 ITHACA, NY Background / References: Wet Aggregate Stability Test The Wet Aggregate Stability (WAS) Test assesses the extent to which

More information

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET

EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET EXPERIMENTAL AERODYNAMICS FLOW TROUGH AN ORIFICE LAB SHEET EMRE KOÇ ONUR GÜNEL 1- Introduction When a fluid passes through a constriction, such as through a sharp-edged hole or over a weir, the constriction

More information

Human Collagen Type III (COL3) ELISA

Human Collagen Type III (COL3) ELISA Human Collagen Type III (COL3) ELISA For the quantitative determination of human COL3 in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-61018 For Research Use Only. Not for use

More information

Module 2, Add on Lesson Turbidity Sensor. Student. 90 minutes

Module 2, Add on Lesson Turbidity Sensor. Student. 90 minutes Module 2, Add on Lesson Turbidity Sensor Student 90 minutes Purpose Construct a sensor to measure the turbidity of water Graph data and reason about curves and linear relationships Calibrate the turbidity

More information

NPTII ELISA Qualitative User Guide neomycin phosphotransferase II Catalog number: PSP 73000

NPTII ELISA Qualitative User Guide neomycin phosphotransferase II Catalog number: PSP 73000 List of contents Lot number Item 96 wells 288 wells 480 wells 4800 wells Antibody-coated 96-well microtiter plates 1 3 5 50 Peroxidase enzyme conjugate (bottles A and B) 0.150 ml 0.350 ml 0.550 ml 5.0

More information

PURE CULTURE TECHNIQUES

PURE CULTURE TECHNIQUES PURE CULTURE TECHNIQUES Most specimens (from animal tissue, plant tissue, or environmental samples) will be mixed, with a variety of bacteria (or other microorganisms). A single gram of feces, for example,

More information

UltraClean Midi Plasmid Prep Kit

UltraClean Midi Plasmid Prep Kit UltraClean Midi Plasmid Prep Kit Catalog No. Quantity 12700-20 20 Preps Instruction Manual Please recycle Version: 05232014 1 Table of Contents Introduction... 3 Protocol Overview... 3 Flow Chart... 4

More information

Mouse Gonadotropin Releasing Hormone (GnRH) ELISA

Mouse Gonadotropin Releasing Hormone (GnRH) ELISA KAMIYA BIOMEDICAL COMPANY Mouse Gonadotropin Releasing Hormone (GnRH) ELISA For the quantitative determination of mouse GnRH in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-58182

More information