SCREEN FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS
|
|
- Cecil Tracy Horton
- 6 years ago
- Views:
Transcription
1 IRRIGATION EQUIPMENT LTD. SCREEN W A T E R FILTERS SERIES 1900 APPLICATIONS Specially designed as a single Control Filter after gravel/sand filter arrays. Used as an economic and compact Secondary Filter in agriculture. ODIS Filtration is The Heart of Every Irrigation System
2 DESCRIPTION A water screen filter with one extrastrong stainlesssteel screen. This filter is offered in two options: A. Horizontal inlet and outlet: models 1900, 19004, 19706, 19708, 197, Horizontal inlet and an outlet at 90 : models 1990, 19904, 19806, 19808, 198, Available in the following sizes: ", 4", 6",, ", 12". Each filter is equipped with a drain valve located on the cover, and with two pressure testing ports, in order to check head loss between inlet and outlet of the filter without interfering with the water flow. Available with two end connections: Flange (F),Victaulic (V). Dimensions & Weight Metric Units A 2 Dimensions & Weight U.S. Units inch D A H T Weight inch inch inch inch lbs 1900 " " " " " " 14" mm inch 12" " 4" 6" " 16" " " 14" " 16" D A H T inch mm mm mm " " " " " " 14" " " 4" 6" " 16" " " 14" " 16" Weight kg , Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved. T D T D A D s 1900 ( ), (4 ) s (6 ), (8 ) 197 ( ), (12 ) H D s 1990 ( ), (4 ) A A s (6 ), (8 ) 198 ( ), (12 ) H H H
3 Recommended Flow Rates Metric Units U.S. Units Series 1900 Inlet / Outlet Recommended Inlet / Outlet Recommended Diameter Flow Rate Diameter Flow Rate inch mm m /h inch U.S. gpm 1900/1990 " 80 up to /1990 " up to / " 0 up to / " up to / " 150 up to / " up to / up to /19808 up to /198 " 250 up to /198 " up to / " 00 up to / " up to 2800 Technical Data Filter screen: stainlesssteel. Single filter screen. Grade of screen: 40 mesh (400 micron). Developed specially as a control screen filter after gravel/sand filter arrays. Max. recommended working pressure: 8 bar (120 psi). Max. pressure: bar (150 psi). Horizontal inlet and outlet: models 1900 ( ), (4 ), (6 ), (8 ), 197 ( ), (12 ) Horizontal inlet and an outlet at 90 : models 1990 ( ), (4 ), (6 ), (8 ), 198 ( ), (12 ). Protective Coating 0 micron extradurable polyester, applied electrostatically and ovencured on a zincphosphate layer for maximal anticorrosion protection. Pressure Relief Valve A pressure relief valve must be inserted before the filtering installation if pressure is not controlled effectively. End Connections Flange Victaulic (F) (V) Each filter is designed and manufactured in order to achieve the highest standard of quality and finish. 20, Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved.
4 HEAD LOSS/ FLOW RATE Metric Units Head Loss ** 19706/19806 (6") /1990 ( ) /19904 (4") /19808 () Flow Rate Q (m³/h) Head Loss dp (bar) 197/198 (") /19812 (12") Head Loss/Flow Rate ** m bar , 1990 ( ) 19004, (4 ) 19706, (6 ) 19708, (8 ) 197, 198 ( ) 19712, (12 ) For a clean filter and 40 mesh screen. ** 2 1 bar=0 kpa=1.02 kg/cm =.2 m (W.C)=14.5 psi Recommended Range m /h 4 20, Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved.
5 HEAD LOSS/ FLOW RATE U.S. Units Head Loss ** 19004/19904 (4") /19806 (6") /1990 ( ) /19808 () /198 (") /19812 (12") 0.5 Flow rate Q (U.S. gpm) Head Loss dp (psi) Head Loss/Flow Rate ** psi , 1990 ( ) 19004, (4 ) 19706, (6 ) 19708, (8 ) 197, 198 ( ) 19712, (12 ) U.S. gpm For a clean filter and 40 mesh screen. 2 1 psi=0.069 bar=6.9 kpa=0.07 kg/cm =0.7 m (W.C) ** Recommended Range 20, Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved. 5
6 ILLUSTRATED PARTS REAKDOWN s 1900, Series s 1990, Catalog Numbers Part No. Description 1900 (") 1990 ( ) (4") (4 ) 1 Handle E E Tightening racket E E Cover E E * 4 Cover Gasket E E Centering Piece E E Extra Strong * Filter Screen E E Inner Gasket E E Pressure Testing Port E E Drain Valve Filter ody PM 100 A 1900 A 1990 Supplied with a 40 mesh screen. PM 100 A A Filter contains one extra strong stainlesssteel screen. Aimed at continued improvement, ODIS reserves the right to change specifications without prior notice. 20, Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved.
7 ILLUSTRATED PARTS REAKDOWN s 19706,19708, 197, s 19806,19808, 198, Catalog Numbers Part No. Description (6 ) (6 ) Cover E19840 E (8 ) 198 (") Extra Strong * 6 E E E E E Filter Screen 7 Screen Seal E E E E E19725 Pressure Test 8 E E E E E Port Filter ody A19806 A19706 A A19708 A olt Washer Wing Nut (8 ) 197 ( ) E E19725 E A (12 ) E19840 E E E E00060 E ER06072 E A (12") E Cover Gasket ER02004 ER02004 ER02004 E ER0 ER0 E1991 E Drive Valve PM12000 PM12000 PM12000 E ER06072 E PM12000 PM12000 PM12000 PM12000 PM12000 A19712 L U L U L U L L22508 L L22750 L * Supplied with a 40 mesh screen. Filter contains one extra strong stainlesssteel screen. Aimed at continued improvement, ODIS reserves the right to change specifications without prior notice. 20, Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved. 7
8 GENERAL INSTRUCTIONS Series 1900 Operation Normal working conditions are obtained when headloss is less than 0.25 bar (4 psi) with clean filter screen. If headloss exceeds 0.25 bar (4 psi) filter is either partially clogged or operating under an excessive flow rate. Maximal operational pressure should not exceed 8 bar (120 psi). Filter is designed to withstand a maximum pressure of bar (150 psi). Verify headloss by inserting pressure gauge with needle into pressure testing ports, (8) assembled at inlet and outlet of filter. If headloss is 0.7 bar ( psi), open the drain valve (9) for seconds. Check the headloss again. If it remains 0.5 bar (7 psi), the screens should be removed for cleaning. Installation Install filter according to drawing of array. Water inlet and outlet are clearly marked by arrows. All filters are supplied with instructions for correct assembly, installation, operation and maintenance. Specially designed ODIS manifolds (series 9000), are available for mounting multiple filter arrays. A pressure relief valve must be inserted before the filtering installation if pressure is not controlled effectively. Array of gravel/sand filters with a single control filter 8 20, Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved.
9 Manual Flushing Manual flushing is performed by simply opening drain valve (9). Check time required to reach a headloss of 0.4 bar (6 psi). Open drain valve (9) and flush filter for 0 seconds. Check pressure reading again: headloss should be 0.25 bar (4psi) or less. Recommended cleaning of filter and checking of screens: every two weeks or when headloss reaches 0.6 bar (9 psi), and on completion of irrigation. Periodic Cleaning Close valve at the inlet of the filter or the array. Open drain valve (9), to release pressure, leave valve open to drain the filter. Remove the filter cover (), by opening the handle (1) or the bolts or the wing nuts, what ever is applicable, wait until the water stops running from the drain valve. Carefully remove screen (6) from the filter body. Removing screen before all the water is drained might cause sediments to penetrate the irrigation system. Rinse filter screen thoroughly using clean water. If necessary use bristles brush to remove particles from the screen (Do not use a wire brush). After cleaning, assemble filter as follows: Verify that filter screen (6), seals and/or gaskets are intact. On models and 4 install the inner gasket (7) on one side of the screen and the centering piece (5) in a special groove on the other side of the screen. On models 6, " and 12 install the screen seals (7) on both sides of the screen. Place the assembly into the filter body (). Place cover gasket (4) so that it fits over filter screen (6) and centers it, place cover () Mount tightening bracket (2) and tighten handle (1) properly (models, 4 ), or install bolts or wing nuts and tighten evenly (models 6, 8,, 12 ) what ever is applicable. On models with wing nuts, the wing nuts should be finger tight only. WARNING: Do not tighten or open cover during operation or under pressure. NOTE: In the event that a bristle brush does not remove particles from screen, immerse filter screens in acid/alkaline solution. Keep it there for some time then rinse thoroughly. Maintenance Each filter is supplied with maintenance instructions, as well as assembly, installation and operation instructions. Apply a layer of grease to thread of handle (1) (models ", 4") or bolt threads (models 6",, ", 12 ), once a year. Any damage to the protective coating of filter must be repaired without delay. Prior to the application of the protective paint, thoroughly clean the damaged spot with wire brush. 20, Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved. 9
10 How To Order Odis Filters 1. Type of filter required. 2. Catalog Number of filter.. End connections (the two connections may be different): Flange Victaulic Vic/Flange (F) (V) (V/F) (V) (F) (V/F) 4. Min./max. pressure. 5. Maximal Flow rate. 6. Additional accessories: Nipples/Valves/Pilots/Relays/Manifolds/Pressure Gauges. 7. Filter arrays: see chapter Other than standard material, required for filter body and cover. 9. Special Coating Requirements. PACKING / SHIPPING DATA Metric Units/ U.S. Units Inlet / Outlet Metric Units (inch) Gross* Weight (Kg) Packed on a pallet Paced in a carton Packed in a carton Packed ia a carton Packed in a carton Packed on a pallet Gross* Weight (lbs) * Gross weight includes packaging materials Packaging Packed in a carton Packed in a carton Packed in a carton Packed in a carton Packed on a pallet Gross Volume (m ) Gross Volume (cu. ft) Packed on a pallet , Hayetsira St., P.O.. 17, KiryatArye, PetachTikva 4910, Israel Tel.: Fax.: odis@odis.co.il Visit us at Copyright , y ODIS Irrigation Equipment Ltd., All Rights Reserved.
FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS
IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer
More informationVAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL
Before installation these instructions must be fully read and understood 2010B 3500B 2020B The VAREC Vapor Control Inc. 2010B/2020B/3500B Series pressure and/or vacuum relief valves have not been tested
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationStainless Steel Aeration Equipment Specification
Section 15 Stainless Steel Aeration Equipment Specification Part 1 - General 1.01 Description A. Scope of Work 1. Furnish, install and test aeration system including air mains, drop pipes, valves, expansion
More informationPARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )
PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and
More informationOperating Instructions
Operating Instructions A-2600 SERIES AWWA SWING CHECK VALVE 500 West Eldorado Street Decatur, Illinois 62522 www.muellercompany.com! WARNING! 1. Read and follow all pertinent instructions carefully. Proper
More informationBasket Strainers. Threaded. Basket. Strainers. Flanged Basket. Strainers
Basket Basket feature top removal of the screen. The screen is in the form of a basket, with a lifting handle, so that all particulate captured and retained by the screen can be easily removed for disposal.
More informationMar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual
Mar Cor Purification Carbon Block Filtration System Operation & Maintenance Manual 3027337 Rev. B 8Jan13 3027337 Rev. B 8Jan13 Operation & Maintenance Manual Table of Contents Page CHAPTER ONE: GENERAL
More informationImproved Water Quality in the Home
Improved Water Quality in the Home Aqua Flo Point-of-Use 69 Aqua Flo Point-of -Use Water Filters Novo offers a wide range of point-of-use filtration solutions. Aqua Flo Economy - A full line of quality
More informationHigh Pressure Filter Assemblies
High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than
More informationGGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation
Gravity Grease Technical Data Submittal Special Precautions Specifications Installation 75" 81" (205.7 (94.0 cm) 19½" 20" (50.8 (49.5 cm) 21½" 20" (50.8 (54.6 cm) 76½" (194.3 cm) 56½" 57" (144.8 (143.5
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS P/N BI 1003 FLOW THROUGH ANTI-ICE SYSTEM KING AIR 200 KIT P/N BI 1001-1 11/08/06 REV: F DRAWING NUMBER BI 1003 REV. F PAGE 1 IMPORTANT NOTICE THE BUTTERFIELD INDUSTRIES FLOW-THROUGH
More informationANDERSON GREENWOOD OS&Y GAUGE VALVES SERIES M5K/M5AK/M5YK
SERIES M5K/M5AK/M5YK Root isolation valves with outside screw and yoke, bolted bonnet construction for pressures up to 6, psi (414 barg) FEATURES M5YK GENERAL APPLICATION M5K-L M5K series gauge valves
More informationLIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:
SERIES 4624B (Cast Iron - Replaces Series 4625 Models) Page 410.1 Issue K SERIES DESCRIPTION The Abrasive Liquid Series heavy duty internal gear pumps utilize hard parts in key wear areas, combined with
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationFencing, locks on access manholes, and other necessary precautions shall be provided to prevent trespassing, vandalism, and sabotage.
previous start next FINISHED WATER STORAGE 7.0 GENERAL 7.1 TREATMENT PLANT STORAGE 7.2 HYDROPNEUMATIC TANK SYSTEMS 7.3 DISTRIBUTION SYSTEM STORAGE 7.0 GENERAL The materials and designs used for finished
More informationSeries 1100 Mechanical Joint Restraint for Ductile Iron Pipe
MEGALUG Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe Features and Applications: Sizes 3 inch through 54 inch Constructed of ASTM A536 Ductile Iron Torque Limiting Twist-Off Nuts Nominal
More informationPlastic Filters. Durable high quality Plastic filters for wide range of filtration applications. up to 50 m 3 /h (220 US gpm)
Plastic Filters Durable high quality Plastic filters for wide range of filtration applications flowrates filtration degrees diameters max. operating pressure up to 50 m 3 /h (220 US gpm) 3500-22 micron
More informationHRO-50 Water Purifier
HRO-50 Water Purifier Product Installation & Operation Manual Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd. Content Important Notes P2 Product Functions P3-P5 Installation Instructions
More informationBAYFILTER SPECIFICATIONS
PART 1.00 GENERAL 1.1 DESCRIPTION BAYFILTER SPECIFICATIONS A. The BayFilter system s internal components manufacturer selected by the Contractor and approved by the Engineer, shall furnish all labor, materials,
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower
More information5505L FLANGE BOLT DISCS
MECHANICAL PACKING INSTALLATION INSTRUCTIONS 0L FLANGE BOLT DISCS PREPARATION Ensure stud threads are long enough to allow nuts to make contact with metal faces. Precaution: Good bolting practice requires
More informationThis section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems.
NORTH MARIN WATER DISTRICT STANDARD SPECIFICATIONS SECTION 15056 DUCTILE-IRON PIPE AND FITTINGS PART 1 GENERAL 1.01 DESCRIPTION This section includes materials and installation of ductile-iron pipe and
More informationSeries 2000PV Mechanical Joint Restraint for PVC Pipe
Series 2000PV Mechanical Joint Restraint for PVC Pipe Features and Applications: For restraining plain end PVC pipe at mechanical joint fittings and appurtenances Sizes 3 inch through 36 inch Sizes 42
More information12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping
MUELLER TAPPING MATERIALS AND SPECIALTY VALVES 12.1 Shaded area indicates change Rev. 7-16 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including
More informationMODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications
MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications Mar/2008 v1.0 SECTION 02255 HYDRAULICLY DRIVEN STEEL UNDERPINNING PILES PART 1 GENERAL 1.01 SCOPE OF WORK The work shall
More informationMicrofil GP. Range. Validation Guide. World Class Filtration Solutions
Microfil GP Range Validation Guide World Class Filtration Solutions Contents Microfil GP Range Validation Guide Introduction 3 - Construction Microfil GP Materials of Construction 4 - FDA Approval - Dimensions
More informationSeries A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100
Series A-C 9100 Single Stage Double Suction Large Split Case TECHNICAL Brochure BAC9100 TABLE OF CONTENTS Useful Pump Formulas 2 Pump Engineering Data 3 Materials of Construction 4 Exploded View 6 USEFUL
More informationProcess Inline Filter, Change-Over
Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.
More informationFS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)
Wastewater Flow Distributor Technical Data Submittal Special Precautions Specifications Installation 24½" (62.2 cm) 12½" (31.8 cm) 24½" (62.2 cm) (30.5 cm) SUBMITTAL STANDARD: 4" plain end inlet/outlet
More informationDISTRIBUTION TECHNOLOGY SAVES WATER. SAVES SALT. SAVES THE ENVIRONMENT. Where Innovation Flows
DISTRIBUTION TECHNOLOGY SAVES WATER. SAVES SALT. SAVES THE ENVIRONMENT. Where Innovation Flows WHAT IS VORTECH Vortech is the world s most innovative and efficient universal distribution system for water
More informationTerrain HDPE. Product Guide
TAGIG1-PT JULY 2009 Terrain HDPE Product Guide Terrain HDPE BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE No. 07/4479 A modern high density polyethylene system with many advantages over cast iron and other
More information2 Through 10 Line Size Filters Model AKC-0280 Model AKC-0880 Balston Natural Gas Filters Balston Compressed Gas Filters Balston high flow rate compres
Pressure rating to 1440 psig Meets U.S. and Canadian codes for natural gas filters Flow rates to 183 million standard cubic feet per day High efficiency removal of suspended liquid and solid impurities
More informationBINAR Quick-Lift System
BINAR Quick-Lift System Install and Training Original Document - July 1, 2015 1 What to expect The installation, set-up, and training process takes an average of 1.5 days (12 hours) per unit. On the first
More informationINSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER
INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER I. SAMPLER SUSPENDED BY CABLE The Vortox Liquid Sampler is a precision instrument manufactured of stainless steel, easy to install,
More informationG-FIRE GROOVED COUPLINGS
G-FIRE GROOVED COUPLINGS Figure 5 G-FIRE Rigid Page 5 Figure 5 Flexible Page GRINNELL are designed for grooved end pipe and are available in nominal sizes of 25mm (") to 3mm (2") including BS, and ISO
More informationRead Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED
Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are
More informationD-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves
TAPPING VALVE MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D. PVC--Also outlet sealed
More informationSECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)
SECTION 02623 HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE) PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required and install high density
More informationInstallation Instructions EQ-400 Whole House Water Filter
Installation Instructions EQ-400 Whole House Water Filter Welcome to the Aquasana experience. You are about to enjoy clean, clear water and the peace of mind that comes from knowing award winning filter
More informationSECTION LAYING AND JOINTING BURIED PIPELINES
SECTION 02650 LINES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Installation of all underground pipelines. Provide pipeline materials, coatings and linings as specified and pipe of the types, sizes
More informationINDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series
INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment
More informationUniversal Tilting TV Mount 32" to 60" Installation Instructions
Universal Tilting TV Mount 32" to 60" Installation Instructions Tiltable LCD / TFT TV Wall Mount Material: 2.0mm Cold Rolled Steel Plate TV size: 32" - 60" Tilt angle: 0-15 degrees Max load capacity: 165
More informationSECTION 5 E-Treat Water Conditioning Systems
SECTION 5 E-Treat Water Conditioning Systems WaTEr QualITy PrOduCTS Catalog 10 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts
More informationCompressed Air Systems. Compressed Air Filters. Balston Microfiber Filter Assemblies. Product Features
Compressed Coalescing Balston Microfiber Filter Assemblies Balston Coalescing Compressed protect your equipment and delicate instruments from the dirt, water, and oil usually found in compressed air. Balston
More informationd n g a n a ck a tio cia lica Filters ctio 3 S ctio n n 3 T ctio 2 S ctio 2 T ctio 1 S d C ctio 1 T d C ria 904L rie e S Ordering Number Description
B-16 B-16 FT, FB, FI and FW B-163 Filtration Definitions Sintered element: metal powder (alloys are available) is pressed in a die at sufficient pressure that the powder particles adhere at their contact
More informationConsolidated* Electromatic* Ball Valves
GE Oil & Gas Technical Specifications 05/2012 3500 Series Consolidated* Electromatic* Ball Valves Provides automatic or manual overpressure startup for steam boiler systems and assists startup and shutdown
More informationType 56 Butterfly Valve
Standard Features (Sizes -/2" ") Standard model (-/2" ") has Body and Disc for better chemical resistance at temperatures higher than can be achieved with. " has body and disc as standard. Our 3/3 stainless
More informationUL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves
UL / FM TAPPING VALVE SECTION Rev. 2-15 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D.
More informationMeter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SC Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities
ADDENDUM NO. TO Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities Date of Addendum: December, 00 Hethcoat & Davis, Inc. 78 Franklin Road,
More informationGrease Interceptors. Design & Operation. Material & Characteristics
Grease Interceptors Dormont offers a full line of grease interceptors for installation on cooking/prep sinks, pot, pan & scullery sinks and dishwasher applications. Dormont offers a variety of interceptor
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS
PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment
More informationST 19 Aluminium Manually Controlled Electric Model
ST 19 Aluminium Manually Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the height of the studs before
More informationOwners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.
Visit us online at www.uswatersystems.com US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual Owners Manual Models: 200-RODI4-XXX US Water 4 Stage RO/DI System REVISION 1.0, 5/12/2015
More informationISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION
ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION FIBERGLASS PACKAGE LS SITE PLAN PAGE No. 111 NUMBER: FG-LS-SITE-PLN FIBERGLASS PACKAGE LS PIPING PLAN PAGE No. 112 NUMBER: FG-LS-PIPE-PLN
More informationHIGH SEAL ULF Live Loaded Packing System
Instruction Manual HIGH-SEAL Live-Loaded Packing HIGH SEAL ULF Live Loaded Packing System Contents Introduction... 1 Scope of Manual... 1 Description... 2 Spring Selection... 3 Installation... 3 Parts
More informationThe Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo
Filters The Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo filters are easily installed and cartridge replacement
More informationAxiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions.
Axiom www.hsiheadwalls.com SURFACE MOUNTED ARRAY Patient Headwall Installation Instructions Installation Guidelines Tel: 925.427.7800 Fax: 925.427.0800 support@hsiheadwalls.com Hospital Systems Inc. 750
More informationPreparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders
GEP-6050 Rev. F 23777 Ref. I.D.: 8681 Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders WARNING USER SHOULD READ AND
More informationDETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS
5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS 1.0 SCOPE 1.1 Provide
More informationLoading Arm Installation, Maintenance & Safety Manual
Loading Arm Installation, Maintenance & Safety Manual Version Loading Arm Hot Line: 1-800-547-9393 Dear OPW Customer: Thank you for selecting OPW Engineered Systems, Inc. ("OPW"), and giving us the opportunity
More informationSECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)
SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) PART 1 GENERAL 1.1 SCOPE 1.1.1 The manufacturer shall furnish a low profile, multi-tray Air Stripper for removal of volatile organic
More informationKF-2S Bulletin 8/16/2002 3:19 PM Page 1 (3,1) BULLETIN KF-2S WATER FILTERS & REPLACEMENT CARTRIDGES FOR SEDIMENT REMOVAL.
KF-2S Bulletin 8/16/2002 3:19 PM Page 1 (3,1) Keystone Filter BULLETIN KF-2S WATER FILTERS & REPLACEMENT CARTRIDGES FOR SEDIMENT REMOVAL KF-2S Bulletin 8/16/2002 3:20 PM Page 2 (1,1) What is Sediment Filtration?
More informationSerial SA Metering Elements
Lubricant inlet Outlet Characteristics Working pressure: max. 400 bar min. 20 bar; Working pressure without check valves for ricirculating systems: min. 12 bar(170 psi); N. cycles per minute: max. 120;
More informationFiberstars Lighted Laminar Flow Fountains
Fiberstars Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Lighted Laminar Flow Fountain. The maximum lighted
More informationTHE INSTALLING INSTRUCTION FOR CONCEALED TANK
THE INSTLLING INSTRUCTION FOR CONCELED TNK Important remind: 80mm300kgf FFL ccessories List:. Please read through this Instructions carefully prior to installation, and our company shall not be responsible
More informationPROflex* 60 Hz Reverse Osmosis Machines from 50 to 360 gpm
Fact Sheet PROflex* 60 Hz Reverse Osmosis Machines from 50 to 60 gpm Flexible Design PROflex has 0 base configurations using 8 to 7 elements that allows user to choose various pumps and membrane element
More informationRosemount 405 Compact Orifice Primary Element
Rosemount 405 Compact Orifice Primary Element SPECIFICATIONS Performance Discharge Coefficient Uncertainty TABLE 20. 405 Compact Orifice Primary Element Type 405C (Conditioning Compact) 405P (1)(2) (Standard
More informationGB-75. Submittal Specifications Installation Application Specific Details
GREASE INTERCEPTOR TECHNICAL DATA Submittal Specifications Installation Application Specific Details 38½" 51½" (1,308 (978 mm) 13½" 12½" (343 (318 mm) 38" 26" (660 (965 mm) 68" 46" (1,168 (1,727 mm) 33½"
More information4 1 /2 MARK 73-5 AMERICAN FLOW CONTROL. It s What We Know. AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING 4 1 /2 MARK 73-5 FIRE HYDRANT
AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING FIRE HYDRANT AMERICAN FLOW CONTROL It s What We Know. CONSTRUCTION AMERICAN-DARLING FIRE HYDRANT OPERATING NUT Cast one-piece bronze operating nut. Design
More informationCONCRETE STEPS, HANDRAILS, AND SAFETY RAIL
SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES
More informationCANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural cantilever rack design. In addition, it is
More informationST XX28 Stainless Steel Thermostatically Controlled Electric Model
DIXONS SURGICAL INSTRUMENTS LTD, 1 ROMAN COURT HURRICANE WAY, WICKFORD BUSINESS PARK WICKFORD, ESSEX, SS11 8YB, UK TEL: +44 (0)1268 764614 - FAX: +44 (0)1268 764615 EMAIL: info@dixons-uk.com - WEB: http://www.dixons-uk.com
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min
Return Filters E 9 E E Tank top mounting Connection up to G Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against
More informationNOTICE OF DISCONTINUATION,
Sizes ", ", ", 6", 8", " NOTICE OF DISCONTINUATION, Effective May st Mueller Systems is discontinuing our current line of strainers. We will continue to offer our plate strainers on a first come, first
More informationEngineering Data Pack HD Industrial Duty Pumps
Engineering Data Pack HD Industrial Duty Pumps Version. Excellence at work. Excellence in life. Table of Contents 0A Pump Mounting Dimensions 0A Pump Mounting Dimensions with Flanged Ports Flanged Port
More informationYARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505
Advanced construction features of this high pressure drop angle globe valve provide quality and long service life. FEATURES GENERAL APPLICATION In addition to continuous blowdown service, the Yarway high
More informationSECTION TAPPING SLEEVES AND VALVES
SECTION 33 12 16.17 TAPPING SLEEVES AND VALVES PART 1: GENERAL 1.01 SCOPE Furnish, install and test all tapping sleeves, tapping valves, and tapping saddles as shown on the Drawings. 1.02 RELATED WORK
More informationTECHNO Male-Threaded, Grooved and Plain End Check Valves. Low pressure loss, lightweight design with compact construction
TECHNO Male-Threaded, Grooved and Plain End Check Valves Low pressure loss, lightweight design with compact construction TECHNO A well-known Brand with Past History and a Brand New Future! Techno Corporation
More informationWater Filtration System
GE Appliances Water Filtration System Faucet & Base Owner s Manual GNUT05Z01 GNUV10Z01 GNUL30Z01 GE Answer Center 800.626.2000 7178896-2 Part No. 215C1002P006 2 Pub. No. 49-5804 Congratulations! You Are
More informationUnderground fire hydrants
Underground fire hydrants The company was founded in 987 by transforming the former CSA, which was a trading company dealing with pipes and valves for water networks, into a manufacturing company, through
More informationStandard and Low-Flow 100 PLUS Powder Feed Pumps
Instruction Sheet P/N 036G Standard and Low-Flow 00 PLUS Powder Feed Pumps Introduction Standard and low-flow 00 PLUS powder feed pumps are used to pump organic and metallic powder coatings to powder spray
More informationSPECIFICATIONS SECTION FLOOD CONTROL GATES. A. ASTM C 39 - Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens.
SPECIFICATIONS SECTION FLOOD CONTROL GATES PART 1 GENERAL 1.1 SECTION INCLUDES A. Flood Gates. 1.2 RELATED SECTIONS A. N/A. 1.3 REFERENCES A. ASTM C 39 - Standard Test Method for Compressive Strength of
More informationBoss Water Systems Australia Reverse Osmosis System Model 021-4P-GM
Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM Congratulations on your purchase of the most advanced water purifier system available! Installation and Service Guide short web version,
More informationPSP Series Water Purification Systems
Operations and Maintenance Manual for PSP Series Water Purification Systems PSP-1000 PSP-1600 PSP-2700 Rev. 2 / 08/26/14 Compact Design, Self-Contained Water Processing Unit for Point-Of-Use or Point-Of-Entry
More informationvapor control systems Quality, Dependability, Service. Reputation Built on Valve Concepts, Inc. com A Cashco, Inc.
vapor control A Cashco, Inc. Company systems Reputation Built on Quality, Dependability, Service. Get Consistent Quality By involving every employee in our ISO 9001:2000 Quality Assurance Program, you
More informationTDC46M Carbon Steel Thermodynamic Steam Trap with Maintainable Seat
2 3 4 7 6 5 8 9 1 Optional extra V1 integral blowdown valve See spare parts for details on how to order; Alternatively please specify at the time of order placement. escription The TC46M is a carbon steel,
More informationAmerican Metal Specialties, Inc.
American Metal Specialties, Inc. www.cablerailings.com (253) 272-9344 (253) 627-3843 Fax PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 05 73 00 STAINLESS STEEL ORNAMENTAL HANDRAILS AND RAILINGS For best
More informationGeneral Specification
General Specifications TB600G Laser Turbidity Meter GS 127A1 General With the recent development in membrane filtration technologies, organic filters have come into practical use as a highperformance treatment
More informationApplications A Balston Nitrogen Generator Food Industries Purging and blanketing Packaging/mixed gas Preservation Color retention Processing/mixing Pr
Filtration 29 Balston OEM Nitrogen Generators Applications A Balston Nitrogen Generator Food Industries Purging and blanketing Packaging/mixed gas Preservation Color retention Processing/mixing Product
More information200 Series In-Slab Pool Fittings
230 Series nti-vortex Plate 2-2 231 Series Sump 2-3 234 Series Sump 2-4 236 Series Sump 2-5 253 Series Overflow 2-6 255 Series Overflow/Drain 2-7 261 Series Vacuum Fitting 2-8 263 Series Eyeball Fitting
More informationSAPAG. A full range of API 526 flanged safety relief valves for process applications, gas, steam and liquid. Safety Relief Valve Series 8100/8200
SAPAG A full range of API 526 flanged safety relief valves for process applications, gas, steam and liquid. Features Full compliance to API RP 520 and standards 526, 527. Certified ASME Section VIII on
More informationBUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466
BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein
More informationSPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS
Page no. :1 of 11 SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS Prepared by: Eng. T. Lev (-חתום-) Checked by: I. Bester (-חתום (- Approved by: Eng. Y. Samoocha (-חתום (- 1 Page no.
More informationCast Steel Bolted Bonnet Stop Check Valves Sizes: 2 thru 14 Pressure Class: 150 thru 1500
ast Steel olted onnet Stop heck Valves Sizes: 2 thru 14 Pressure lass: 150 thru 1500 Manufactured by Newmans 45 Newco ast arbon Steel olted onnet Valves Typical Newco ast Steel olted onnet Stop heck Valve
More informationWater Quality Specification for Power Supplies
Technical Note #6 Water Quality Specification for Power Supplies Introduction The cooling water for Alpha Scientific Power Supplies must meet certain minimum specifications in regard to quality and flow
More information(01) Thermo Bond Buildings Military Service Shelter: DOG KENNEL OPERATING AND SETUP MANUAL MSS-RP-1-20P
Thermo Bond Buildings Military Service Shelter: DOG KENNEL OPERATING AND SETUP MANUAL MSS-RP-1-20P Tool-free assembly Portable Durable Climate-controlled Warnings & Safety Quick overview Assembly Maintenance
More informationST 19 T Aluminium Thermostatically Controlled Electric Model
ST 19 T Aluminium Thermostatically Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the height of the
More information