Implementation of Magnetic Meters for Irrigation Volumetric Measurement. Stuart W. Styles 1 and Lynn Groundwater 2

Size: px
Start display at page:

Download "Implementation of Magnetic Meters for Irrigation Volumetric Measurement. Stuart W. Styles 1 and Lynn Groundwater 2"

Transcription

1 Implementation of Magnetic Meters for Irrigation Volumetric Measurement Stuart W. Styles 1 and Lynn Groundwater 2 1 Professor, Cal Poly State University BioResource and Agricultural Engineering Dept. and Director, Irrigation Training and Research Center. Phone: (805) Fax: (805) sstyles@calpoly.edu 2 Student Engineer, Cal Poly ITRC. Phone: (805) Fax: (805) lgroundw@calpoly.edu ABSTRACT The irrigation industry is experiencing a growth in the use of magnetic meters for measuring the flow rate and volume in irrigation pipelines. Historically, propeller meters have been the device selected by users. New legislation in California (SB7x7) will require measurement devices at key locations for irrigation water delivery. Some users are very interested in the magnetic meter for making the measurement at the turnout or farm gate. The key feature of the new meter is the ability for the device to work in less than ideal flow conditions. Electromagnetic meters have been tested by the Irrigation Training and Research Center in lab and field pipelines located less than the 10 diameters upstream of disturbances with good results. There are several manufacturers that are selling units to the irrigation market as well as several types of magnetic meter designs. This paper discusses how a magnetic flow meter works, advantages/disadvantages of this type of meter, test results, and new guidelines for field applications. INTRODUCTION Background Magnetic meters have been available for a number of years. Historically, the main problem with using a magnetic meter was the cost. Units were sold at about $1,000 per inch or approximately $12,000 for a 12-inch (30.5 cm) diameter pipe application. For agricultural applications, this cost was prohibiting widespread use of the meters. Currently, the demand for the magnetic meters has increased and prices have decreased significantly. The cost for a magnetic meter is quickly approaching the cost of the tradition measurement device for pipelines the propeller meter. Additionally, new regulations in California have prompted new interest in measurement devices that are both robust and accurate. SB7x7 bill is California legislation that pertains to agricultural water users and should be active in February The Department of Water Resources has adopted regulations that provide for a range of options that agricultural water suppliers may use, or implement, to comply with the requirement that suppliers measure the volume of water delivered to customers with sufficient accuracy and to submit an annual report to the department that summarizes aggregated farm-gate delivery data, on a monthly or bimonthly basis, using best professional practices (California Water Code (a)). The Department of Water Resources requires the agricultural water suppliers to prepare and to adopt agricultural water management plans by December 31, 2012, to update those plans by December 3, 2015, and every 5 years thereafter. The agricultural water suppliers shall measure the volume of water delivered to customers, adopt a pricing structure for water customers based on the quantity delivered, and implement additional efficient managing

2 practices. Agriculture water suppliers who do not meet the water management planning requirements established by this bill are not eligible for state water grants or loans, effective in The accuracy and long-term success of any flow measurement program depends on many factors. Magnetic flow measurement is rapidly becoming the technique of choice in pipelines because of its simplicity and accuracy. However, the application of this technology has been limited in the past because of standard practice guidelines for magnetic flow meters, which required installing the meters in a straight section of pipe at least 8-10 pipe diameters from any source of turbulence. In addition, standard practice recommends having at least two pipe diameters of straight unobstructed pipe downstream from the meter. However, in the case of many irrigation pumping plants, turnouts, and deliveries, these conditions can rarely be met without extensive and expensive modifications. Therefore, the Irrigation Training and Research Center (ITRC) at Cal Poly State University, San Luis Obispo is currently investigating electromagnetic flow meters for potential applications under nonstandard conditions. Several current manufacturers claim that their magnetic meters can perform well even in locations where only two diameter lengths of straight pipe are available. Testing was done by the ITRC on several magnetic meters at the Cal Poly Water Resources Facility to evaluate comments by the manufacturers and to make recommendations to irrigation districts and growers interested in this new technology. Goals of this research: - The accuracy of the magnetic meters in locations that are less than optimal - The sensitivity of meters to increasing amounts of turbulence Since this research was conducted, there have been numerous field installations of magnetic meters in various irrigation applications in California. In January 2012, the Shafter-Wasco Irrigation District installed 25 magnetic meters. The general manager reported that the magmeters have been installed and are performing well. Magnetic Meters Operating Principle According to Faraday s Law, a voltage will be induced proportional to the velocity of a conductor as it moves at right angles through a magnetic field. The water in the pipe is the conductor. By simply measuring the voltage, a magnetic meter is able to calculate the volume of the liquid passing through a controlled section. Faraday's Formula: E is proportional to V x B x D E = The voltage generated in a conductor V = The velocity of the conductor B = The magnetic field strength D = The length of the conductor This principle works for irrigation water passing through the magnetic field generated by the magnetic meter since the water acts as the conductor. The basic operating principle for

3 magnetic meters is illustrated in Figure 1. Note that this discussion is limited to full-bore or in-line magnetic meters. There are several other types of meters on the market but this type is the one that was evaluated. 1 Figure 1. Operating principle for full-bore magnetic meter (Omega 2009) As seen in Figure 2, there are two electrodes located inside the magnetic meter to measure the induced voltage. The flow rate/totalizer indicator is located on the top of the unit. These units can be placed at any angle. It is recommended that they be rotated so that one of the electrodes does not sit on the bottom of the pipe. This helps prevent problems from sediment covering the electrode. Note that on the unit in Figure 2, the magnetic field is generated by an insert unit into the pipeline. Some manufacturers install the coils to generate the magnetic field outside of the spool piece. 1 Reference to any specific product does not imply an endorsement or recommendation of use by the authors. The product names are included for completeness and clarifications in this paper.

4 Figure 2. View of typical magnetic meter (SeaMetrics 2009) Advantages of Magnetic Meters - Highly accurate even with some flow disturbance. - No headloss caused by meter. - Not impacted by trash, sediment, or sand. - Measures a wide range of velocity. This is a key criterion in areas that have seasonal high flows combined with very low flows. - Instantaneous and volumetric totalizing capability. - Measurement accuracy is NOT affected by varying canal water levels. - Minimal maintenance required. - Temperature of the liquid has no effect on accuracy. Disadvantages of Magnetic Meters - Cost is a major constraint. Recently the cost has dropped dramatically, but this is still the most expensive option in some cases. - Pipe must be full (as is the case in most agricultural applications). - Installation into existing sites is often difficult and expensive. - Sensitivity to turbulence. Turbulence and Magnetic Meters Magnetic meters have been considered particularly tricky for pumping plants and turnouts, because of the meter s sensitivity to turbulence. For example, one of the main problems associated with turnouts is the turbulence that occurs just downstream of the gate. Figure 3 shows a typical turnout application with a magnetic meter.

5 Figure 3. Conceptual sketch of magnetic meter installation for turnouts (not to scale) In 1998, Hanson and Schwankl published results from non-optimal flow meter testing in their paper Error Analysis of Flowmeter Measurements. Pipeline measurements were taken with different types of flow meters to determine the effects on error resulting from different degrees of turbulence caused by elbows, check valves, and a partially opened check valve. Measurements were made at 2, 5, 10, and 15 pipe diameters downstream from the source of turbulence. The results from Hanson and Schwankl (1998) indicated that for generally acceptable accuracy with propeller meters, pitot meters, and Doppler meters, measurements should be taken upstream of valves. The tests found that in some circumstances even with as little as 2 or 5 pipe diameters upstream of a flow meter, there were still large errors with all meters under conditions of severe turbulence. Since most applications require the flow measurement downstream of a valve or turnout gate, manufacturers have recently claimed that their magnetic flow meter technology is now able to work effectively in situations where there are as little as two diameters of pipe length available. ITRC tested several magnetic meters at the Cal Poly Water Resources Facility to investigate these claims. APPLICATIONS Cal Poly Water Resources Facility Strawberry Application ITRC conducted test results for six, four-inch SeaMetrics AG2000 Magmeters tested at the Water Resources Facility in August The purpose of these tests was to verify the performance of the AG2000 magmeters under less than optimal conditions, similar to which is seen on strawberry fields on California s Central Coast. The meters had been installed in

6 the field for the last two irrigation seasons. The test results indicate that none of the magmeters exhibit a degradation of accuracy under these conditions. The magmeters were installed at the Water Resources Facility, in series with a 2-inch pressure regulating valve directly downstream of the magmeter, and a disc filter (Figure 1). The discs were removed from the filter due to immediate clogging. Figure 4. Test configuration for 4-inch magnetic meter A test was run at four different flow rates, ranging from gpm. The results were compared to the control unit for these tests, the ITRC weighing tank. The results from the testing are summarized in Table 1. The percent accuracy shown in the following tables is based off of the formula: % = (Test meter Control unit) / Control unit

7 Table 1: Summary of Grounded Test Results SeaMetrics AG2000 Magmeters Cal Poly ITRC Water Resources Facility Meter #: 1 S/N: Meter #: 2 S/N: AVG 0.69 AVG 0.28 r r Meter #: 3 S/N: Meter #: 4 S/N: AVG 0.79 AVG 0.56 r r Meter #: 5 S/N: Meter : #6 S/N: AVG 1.06 AVG 0.67 r r Meter #: 7 S/N: AVG 0.85 r Cal Poly Water Resources Facility Vertical Turbine Application Tests were conducted over a flow range of approximately 0.8 to 115 lps (12 to 1,800 gpm) using a second magnetic meter in optimal flow conditions as the control unit. The control unit used for the test was a 30.5 cm (12-inch) McCrometer Ultra Mag flow meter, which had been calibrated using the weighing tank facility at the Water Resources Facility. ITRC did not attempt to verify the true accuracy of the AG2000 flow meter readings, only the accuracy compared to the control units.

8 A magnetic flow meter was mounted on the Water Resources Facility Pump #2, downstream of a cast-iron concentric reducer, and immediately downstream of a butterfly valve (refer to Figure 5), designated as Test #1. The retail cost of this 25.4 cm (10 inch) magnetic meter is $1,500 which is comparable to a standard propeller meter. This test configuration was designed to represent the worst possible conditions imaginable for an actual irrigation application. Figure 5. AG2000 test condition for Test #1 on 10-inch (30.5 cm) pipe Once the initial flow rate was established, turbulence was introduced into the pipeline. The butterfly valves were adjusted during the tests from wide open to 75% and 90% closed in Tests #1 and #2, respectively. This testing would represent the worst possible case for irrigation applications. The error analysis of the AG2000 flow meter test results is summarized in Table 2. The accuracy was less than +2% when the butterfly valve was partially closed, up to 50%. The percent error was more than -10% when the butterfly valve was closed more than 75%. This increase in percent error may be attributed to the jetting effect of the cast-iron concentric reducer coupled immediately upstream of the butterfly valve. By comparison, the results reported by Hanson and Schwankl (1998) for partially closed butterfly valves with a propeller meter mounted two diameters downstream were ±14% at 42.7 lps (668 gpm), ±15% at 73.7 lps (1,153 gpm), and ±2% for flow rates of lps (2,190 gpm). The valve was closed 10 degrees (out of 90 degrees) to provide the throttling effect. Based on the results of their study, it was recommended to always use a six vane straightening arrangement if measuring the flow rate downstream of a throttled butterfly valve. The test results indicate that the AG2000 Irrigation Magmeter can be installed downstream of partially closed butterfly valves or other sources of turbulence without excessively degrading accuracy.

9 Table 2. AG2000 Test Results at Cal Poly ITRC Water Resources Facility Test # Test # cm (10 ) meter Ultra Mag Flow Rate (lps) Ultra Mag Flow Rate (gpm) AG2000 Flow Rate (lps) AG2000 Flow Rate (gpm) Error Valve Position Open , , % closed , , % closed , , % closed , , % closed In summary, the test results indicated that under conditions of severe turbulence due to a partially closed butterfly valve, the flow meter readings were not adversely affected. For the 25.4 cm (10 inch) AG2000 flow meter, a partially closed butterfly valve coupled with a pump discharge caused errors of 1-2% up to 50% valve closure. The recorded percent error was generally reduced at the higher flow rates. CONCLUSION The test results completed by the ITRC indicate that the magnetic meter tested can be installed downstream of partially closed butterfly valves or other sources of turbulence without excessively degrading accuracy. Additionally, the magnetic meter is able to provide accurate readings to within ±2%, which is well within the limits expected for agricultural delivery. The costs of these units have also decreased to the point where they are competitive with traditional devices that cannot handle the turbulence associated with some irrigation applications. The accuracy of the devices fits well within the parameters set up by the SB7x7 guidelines developed by the DWR. REFERENCES Hanson, B.R., and Schwankl, L.J Error Analysis of Flowmeter Measurements. J. Irrig. and Drain. Engrg., ASCE 124(5), SeaMetrics, Inc Instructions: AG2000 Irrigation Magmeter. OMEGA Engineering Technical Reference, Introduction to Magnetic Flow Meters.

Implementation and Field Calibration Pipeline Doppler Meters in Northern California Stuart Styles 1, Lynn Groundwater 2, and Jim Weathers 3

Implementation and Field Calibration Pipeline Doppler Meters in Northern California Stuart Styles 1, Lynn Groundwater 2, and Jim Weathers 3 Implementation and Field Calibration Pipeline Doppler Meters in Northern California Stuart Styles 1, Lynn Groundwater 2, and Jim Weathers 3 1 Irrigation Training and Research Center, BioResource and Ag

More information

Flow Conditioning for Irrigation Propeller Meters

Flow Conditioning for Irrigation Propeller Meters Flow Conditioning for Irrigation Propeller Meters Katie Englin Product Manager McCrometer Hemet, California 3255 W Stetson Ave Hemet, CA 92545-7799 Email: katiee@mccrometer.com Dean E. Eisenhauer Professor

More information

IMPROVED WATER RESOURCE MANAGEMENT USING AN ACOUSTIC PULSED DOPPLER SENSOR IN A SHALLOW OPEN CHANNEL

IMPROVED WATER RESOURCE MANAGEMENT USING AN ACOUSTIC PULSED DOPPLER SENSOR IN A SHALLOW OPEN CHANNEL IMPROVED WATER RESOURCE MANAGEMENT USING AN ACOUSTIC PULSED DOPPLER SENSOR IN A SHALLOW OPEN CHANNEL Mike Cook 1, PhD Craig Huhta 1 SonTek/YSI Inc., San Diego, California, USA Abstract. Over the years

More information

EO = IHP= The efficiency of a pumping plant is calculated as follows:

EO = IHP= The efficiency of a pumping plant is calculated as follows: The efficiency of a pumping plant is calculated as follows: EO = QxH 3,960 x IHP where Eo is the overall pumping efficiency, Q is the pump flow rate or capacity (gallons per minute [gpm]), H is total head

More information

TAKING CLOSED PIPING FLOWMETERS TO THE NEXT LEVEL NEW TECHNOLOGIES SUPPORT TRENDS IN DATA LOGGING AND SCADA SYSTEMS

TAKING CLOSED PIPING FLOWMETERS TO THE NEXT LEVEL NEW TECHNOLOGIES SUPPORT TRENDS IN DATA LOGGING AND SCADA SYSTEMS TAKING CLOSED PIPING FLOWMETERS TO THE NEXT LEVEL NEW TECHNOLOGIES SUPPORT TRENDS IN DATA LOGGING AND SCADA SYSTEMS Michael Kohlmann 1 Peter Miramontes 2 ABSTRACT We are seeing some clear trends in water

More information

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter.

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter. TM FPI Mag TM SPI Mag Insertion Flow Meters The only hot tap Full Profile Insertion Flow Meter. Easy to install, rivals performance Economical for medium and large line sizes The total installed cost of

More information

Influence of Supply-Channel Velocity on Farm Delivery Meter Gate Flow Measurement

Influence of Supply-Channel Velocity on Farm Delivery Meter Gate Flow Measurement Howes, Burt, Thorburn. Published in Journal of Irrigation and Drainage Engineering, 143(7), July 2017: 06017003-(1-6) Influence of Supply-Channel Velocity on Farm Delivery Meter Gate Flow Measurement Daniel

More information

Basic Design of Replogle Flumes

Basic Design of Replogle Flumes ITRC Report No. R 02-010 IRRIGATION TRAINING AND RESEARCH CENTER California Polytechnic State University San Luis Obispo, California 93407 www.itrc.org Basic Design of Replogle Flumes Replogle flumes are

More information

USCID Water Management Conference, Dec. 2-5, 2014, Denver, CO. ITRC Paper No. P FLOW MEASUREMENT OPTIONS FOR CANAL TURNOUTS

USCID Water Management Conference, Dec. 2-5, 2014, Denver, CO. ITRC Paper No. P FLOW MEASUREMENT OPTIONS FOR CANAL TURNOUTS USCID Water Management Conference, Dec. 2-5, 2014, Denver, CO. FLOW MEASUREMENT OPTIONS FOR CANAL TURNOUTS Kyle Feist 1 Charles Burt 2 ABSTRACT Volumetric record-keeping, billing, and allocations at irrigation

More information

Pressure Recorders: Low-Cost, Robust, Low-Battery-Use Field Measurement Techniques for Trending Water Pressure

Pressure Recorders: Low-Cost, Robust, Low-Battery-Use Field Measurement Techniques for Trending Water Pressure Pressure Recorders: Low-Cost, Robust, Low-Battery-Use Field Measurement Techniques for Trending Water Pressure Stuart Styles 1 and Kerilyn Ambrosini 2 1 Director, Irrigation Training and Research Center,

More information

WHITE PAPER A New Approach to Accurate Water Flow Measurement - The Study of the FPI Mag Accuracy

WHITE PAPER A New Approach to Accurate Water Flow Measurement - The Study of the FPI Mag Accuracy A New Approach to Accurate Water Flow Measurement - The Study of the FPI Mag Accuracy Page 1 McCROMETER, INC. 3255 W. Stetson Ave., Hemet, CA 92545 PH 951-652-6811 FAX 951-652-3078 2013-2018 by McCrometer,

More information

Case Study. Innovative FPI Mag TM - Full Profile Insertion Mag Meter - Improves City Water Operations Management

Case Study. Innovative FPI Mag TM - Full Profile Insertion Mag Meter - Improves City Water Operations Management Innovative FPI Mag TM - Full Profile Insertion Mag Meter - Improves City Water Operations Management Case Study Page 1 Case Study By Jerry Stultz - Applications Engineer And Curt Worlund - Vertical Marketing

More information

THE ITRC RAPID APPRAISAL PROCESS (RAP) FOR IRRIGATION DISTRICTS. Stuart Styles 1 Charles Burt 2 ABSTRACT

THE ITRC RAPID APPRAISAL PROCESS (RAP) FOR IRRIGATION DISTRICTS. Stuart Styles 1 Charles Burt 2 ABSTRACT THE ITRC RAPID APPRAISAL PROCESS (RAP) FOR IRRIGATION DISTRICTS Stuart Styles 1 Charles Burt 2 ABSTRACT The ITRC Rapid Appraisal Process (RAP) for irrigation projects was created in 1989 as a tool to quickly

More information

The Paradigm Case Method of Flowmeter Selection

The Paradigm Case Method of Flowmeter Selection 1 By Jesse Yoder, Overview One of the most interesting developments in the flowmeter market today is the battle between the newer flow technologies and the traditional flowmeters. New-technology flowmeters

More information

GLENN-COLUSA IRRIGATION DISTRICT FLOW MONITORING PROGRAM ABSTRACT

GLENN-COLUSA IRRIGATION DISTRICT FLOW MONITORING PROGRAM ABSTRACT GLENN-COLUSA IRRIGATION DISTRICT FLOW MONITORING PROGRAM Dennis Perkins 1, Stuart W. Styles 2, Marcus Y. Yasutake 3 ABSTRACT In 1996, the United States Bureau of Reclamation (USBR), Mid-Pacific Region,

More information

FPI Mag Flow Meter. Next Generation Mag Meter: Solving WTP s Tight Installation Dilemma. McCrometer, Inc. (800)

FPI Mag Flow Meter. Next Generation Mag Meter: Solving WTP s Tight Installation Dilemma. McCrometer, Inc.  (800) FPI Mag Flow Meter Next Generation Mag Meter: Solving WTP s Tight Installation Dilemma McCrometer, Inc. www.mccrometer.com/fpimag (800) 220-2279 Lit Number 81000-07 Rev 2.1 / 3-16 TABLE OF CONTENTS: Retrofit

More information

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University Water Measurement Presentation by L. Niel Allen Extension Irrigation Specialist Utah State University to Utah State Engineer s Office Division of Water Rights Salt Lake City, Utah December 11, 2013 Introduction

More information

Accuracy of Round Meter Gates for On-Farm Deliveries

Accuracy of Round Meter Gates for On-Farm Deliveries Accuracy of Round Meter Gates for On-Farm Deliveries Daniel J. Howes, M.ASCE 1 ; and Charles M. Burt, M.ASCE 2 Abstract: Recent California legislation requires irrigation water agencies larger than 25,000

More information

SBx7 Flow Rate Measurement Compliance for Agricultural Irrigation Districts

SBx7 Flow Rate Measurement Compliance for Agricultural Irrigation Districts SBx7 Flow Rate Measurement Compliance for Agricultural Irrigation Districts IRRIGATION TRAINING & RESEARCH CENTER SBx7 Compliance SBx7 Flow Rate Measurement Compliance for Agricultural Irrigation Districts

More information

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE

Master Meter Testing at Water Plants and Pump Stations. Jeff Cruickshank, PE Master Meter Testing at Water Plants and Pump Stations Jeff Cruickshank, PE NC AWWA-WEA Spring Conference Asheville, NC April 11, 2015 Presentation Outline What types of meters are used at WTPs and pump

More information

Agricultural Pumping Efficiency Program. Flow Meters. Helping California Agriculture...

Agricultural Pumping Efficiency Program. Flow Meters. Helping California Agriculture... Agricultural Pumping Efficiency Program Flow Meters Helping California Agriculture... Flow Meters The Agricultural Pumping Efficiency Program is providing this information regarding the importance of measuring

More information

SECTION C FLOW VERIFICATION (CALIBRATION) METHODS FOR WATER USE ACCOUNTING AND REPORTING OF AGRICULTURAL AND OTHER WATER USE IN SOUTH FLORIDA

SECTION C FLOW VERIFICATION (CALIBRATION) METHODS FOR WATER USE ACCOUNTING AND REPORTING OF AGRICULTURAL AND OTHER WATER USE IN SOUTH FLORIDA SECTION C FLOW VERIFICATION (CALIBRATION) METHODS FOR WATER USE ACCOUNTING AND REPORTING OF AGRICULTURAL AND OTHER WATER USE IN SOUTH FLORIDA INTRODUCTION This section of the handbook is intended to assist

More information

GUIDANCE NOTE. Performance of Electromagnetic Meters Designed for Use in Part-Filled Pipes.

GUIDANCE NOTE. Performance of Electromagnetic Meters Designed for Use in Part-Filled Pipes. GUIDANCE NOTE Performance of Electromagnetic Meters www.tuvnel.com Performance of Electromagnetic Meters Introduction Electromagnetic flowmeters designed for use in part-filled pipes may be considered

More information

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Test Book and Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Title Page 405 Compact Orifice Series and 1595 Conditioning Orifice Plate Test Book NOTICE Read this manual before

More information

Flow Meter Use on Dairies

Flow Meter Use on Dairies Larry Schwankl Irriga0on Specialist, UC Coopera0ve Extension 559-646- 6569 schwankl@uckac.edu hep://schwankl.uckac.edu Thanks to Noelia Silva and UC Cooperative Extension - Tulare County for hosting today

More information

ON-FARM WATER CONSERVATION PROGRAM 2013 PROGRAM DESCRIPTION SOUTH SAN JOAQUIN IRRIGATION DISTRICT

ON-FARM WATER CONSERVATION PROGRAM 2013 PROGRAM DESCRIPTION SOUTH SAN JOAQUIN IRRIGATION DISTRICT ON-FARM WATER CONSERVATION PROGRAM 2013 PROGRAM DESCRIPTION SOUTH SAN JOAQUIN IRRIGATION DISTRICT Table of Contents Background and Objectives... 2 Enrollment Process... 3 Solicitation and Application Process...

More information

FPI Mag Flow Meter. Next Generation Mag Meter Measuring Flow in a Pump Station. McCrometer, Inc. (800)

FPI Mag Flow Meter. Next Generation Mag Meter Measuring Flow in a Pump Station. McCrometer, Inc.  (800) FPI Mag Flow Meter Next Generation Mag Meter Measuring Flow in a Pump Station McCrometer, Inc. www.mccrometer.com/fpimag (800)220-2279 Michelle Pawlowicz Marketing Specialist Lit Number 81000-01 Rev 1.0/6-13

More information

Canal Control Training. Charles M. Burt, Ph.D., P.E. Director, Irrigation Training and Research Center San Luis Obispo, California

Canal Control Training. Charles M. Burt, Ph.D., P.E. Director, Irrigation Training and Research Center San Luis Obispo, California http://www.itrc.org/papers/pdf/canalcontroltraining.pdf ITRC Paper 90-001 Canal Control Training Charles M. Burt, Ph.D., P.E. Director, Irrigation Training and Research Center San Luis Obispo, California

More information

University. San Luis Obispo, CA Irrigation Training and Research Center (ITRC)

University. San Luis Obispo, CA Irrigation Training and Research Center (ITRC) NON-STANDARD STRUCTURE FLOW MEASUREMENT EVALUATION USING THE FLOW RATE INDEXING PROCEDURE QIP Stuart Styles 1 Presented at USCID Third International Conference on Irrigation and Drainage San Diego, CA,

More information

Manual of Petroleum Measurement Standards Chapter 5 Metering

Manual of Petroleum Measurement Standards Chapter 5 Metering Addendum 1 July 2009 Manual of Petroleum Measurement Standards Chapter 5 Metering Section 3 Measurement of Liquid Hydrocarbons by Turbine Meters FIFTH EDITION, SEPTEMBER 2005 Addendum to MPMS Chapter

More information

COOLING TECHNOLOGY INSTITUTE

COOLING TECHNOLOGY INSTITUTE PAPER NO: CATEGORY: TP18-23 TESTING COOLING TECHNOLOGY INSTITUTE COMPARATIVE EVALUATION OF PITOT TUBE DESIGNS FOR WATER FLOW MEASUREMENT DEVICES KENNETH W. HENNON, P.E. DAVID E. WHEELER, P.E. CLEANAIR

More information

Order to Talk. Water Measurement Techniques, Water Price and Water Fee collection. 1 Water Measurement Techniques

Order to Talk. Water Measurement Techniques, Water Price and Water Fee collection. 1 Water Measurement Techniques Training for YPs of Asia on Performance Assessment of Irrigation Systems Water Measurement Techniques, Water Price and Water Fee collection Ding Kunlun klding@iwhr.com Beijing, 11 April 2018 Order to Talk

More information

Measuring Applied Water in Surface-Irrigated Orchards

Measuring Applied Water in Surface-Irrigated Orchards reducing runoff from irrigated lands PUBLICATION 8230 Measuring Applied Water in Surface-Irrigated Orchards UNIVERSITY OF CALIFORNIA Division of Agriculture and Natural Resources http://anrcatalog.ucdavis.edu

More information

Water Challenges WORKING TOGETHER TOWARDS SOLUTIONS California-Nevada AWWA Annual Fall Conference Large Meter Testing: Analysis and Calibration

Water Challenges WORKING TOGETHER TOWARDS SOLUTIONS California-Nevada AWWA Annual Fall Conference Large Meter Testing: Analysis and Calibration Water Challenges WORKING TOGETHER TOWARDS SOLUTIONS California-Nevada AWWA Annual Fall Conference 2013 Large Meter Testing: Analysis and Calibration Overview Water Loss Control Water Audit / Balance Format

More information

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc. February 5, 2013 Roy Ratcliffe, President RM Controls, Inc. Volumetric Flow A velocity is a measure of the distance a particle of a substance moves in a given period of time The method of measurement used

More information

Choosing the Right Residential Water Metering Technology

Choosing the Right Residential Water Metering Technology WHITE PAPER Choosing the Right Residential Water Metering Technology ABOUT THE AUTHORS Dr. Mark England is CEO of Sentec Ltd., a research and development organization within Sensus, a Xylem brand, that

More information

Commercial & Industrial Large Water Meters

Commercial & Industrial Large Water Meters Commercial & Industrial Large Water Meters 1 Water Distribution System 2 Large Meter Family 3 Large Meter Family 4 Specifications Clean Water Applications Maximum Operating Temperature: 80 deg F Maximum

More information

By John B. Parrish In,' Associate Member, ASCE, and Charles M. Burt,! Member, ASCE

By John B. Parrish In,' Associate Member, ASCE, and Charles M. Burt,! Member, ASCE CAL POLY MODEL CANAL By John B. Parrish In,' Associate Member, ASCE, and Charles M. Burt,! Member, ASCE ABSTRACT: The Cal Poly Model Canal, located at the Water Delivery Facility. Irrigation Training and

More information

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND JULY 2002 Copyright 2001 H.I.L. Technology, Inc. All rights reserved. This report was

More information

Handling Fluid Fertilizers Selecting the Right Equipment Components

Handling Fluid Fertilizers Selecting the Right Equipment Components Handling Fluid Fertilizers Selecting the Right Equipment Components 9/2/2010 1 Considerations Systematic approach Compatible components Short term vs. long term Plan ahead for future expansion 9/2/2010

More information

Low Pressure Drip/Micro System Design Analysis of Potential Rebate

Low Pressure Drip/Micro System Design Analysis of Potential Rebate Low Pressure Drip/Micro System Design Analysis of Potential Rebate Prepared by: Dr. Charles Burt, ITRC Dr. Dan Howes, ITRC Drip/micro irrigation systems are often referred to as low pressure systems because

More information

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Preso s complete line of Venturis offer reduced operating costs, proven accuracy, and great rangeability. Low permanent

More information

Flow Meter Calibration

Flow Meter Calibration fluid mechanics H4 A compact unit that compares and shows the accuracy, losses and use of fundamental flow meters Key Features Unique quick-change flow meter adaptors and pressure connections Four tube

More information

OTCO 12/11/13 Water Audits Meter Testing & Leaks

OTCO 12/11/13 Water Audits Meter Testing & Leaks OTCO 12/11/13 Water Audits Meter Testing & Leaks Aaron M. Horbovetz PMP, EIT Project Engineer What is a Water Audit? It s like a Scouting before you hunt. Why is an Audit Important? It tells you where

More information

Guidelines for water meter installation Looking after all our water needs

Guidelines for water meter installation Looking after all our water needs Guidelines for water meter installation 2009 Looking after all our water needs Department of Water Report no. 2 July 2009 Department of Water 168 St Georges Terrace Perth Western Australia 6000 Telephone

More information

Universities of Leeds, Sheffield and York

Universities of Leeds, Sheffield and York promoting access to White Rose research papers Universities of Leeds, Sheffield and York http://eprints.whiterose.ac.uk/ This is an author produced version of a paper published in Sensor Review. White

More information

Meeting Date: 09/22/2015 AGM 235. Agricultural engineering (NM) Agricultural production (NM) Agriculture (M)

Meeting Date: 09/22/2015 AGM 235. Agricultural engineering (NM) Agricultural production (NM) Agriculture (M) Modesto Junior College Course Outline of Record AGM 235 I. OVERVIEW The following information will appear in the 2016-2017 catalog AGM 235 IRRIGATION AND DRAINAGE 3 UNITS 36.00 Lecture Hours, 500 Lab Hours

More information

C Addressing Non-Revenue Water with Static Meters. Martin Casillas Director of Sales, US West Kamstrup

C Addressing Non-Revenue Water with Static Meters. Martin Casillas Director of Sales, US West Kamstrup C715-18 Addressing Non-Revenue Water with Static Meters Martin Casillas Director of Sales, US West Kamstrup AWWA C715 Standard 3 AWWA C715 Standard Purpose: Define minimum requirements for potable cold

More information

Flow Measurements for Chilled Water Plant (CWP)

Flow Measurements for Chilled Water Plant (CWP) APMP 2018 TCFF Workshop, 23 Nov 2018 Flow Measurements for Chilled Water Plant (CWP) Dr LUO Rongmo, A*STAR 1 1. Standards and regulations for Green Buildings of Singapore 2. Flow measurement for Chilled

More information

Clamp on Ultrasonic Flow Measurement Principal Transit Time Doppler What Distinguishes Flexim Technology

Clamp on Ultrasonic Flow Measurement Principal Transit Time Doppler What Distinguishes Flexim Technology Clamp-On Flow Meter Technology For Leak Detection Clamp on Ultrasonic Flow Measurement Principal Transit Time Doppler What Distinguishes Flexim Technology external measurement of internal flow Measurement

More information

MODERNIZATION OF THE DELANO-EARLIMART IRRIGATION DISTRICT. Charles M. Burt 1 and Dale R. Brogan 2 ABSTRACT

MODERNIZATION OF THE DELANO-EARLIMART IRRIGATION DISTRICT. Charles M. Burt 1 and Dale R. Brogan 2 ABSTRACT MODERNIZATION OF THE DELANO-EARLIMART IRRIGATION DISTRICT Charles M. Burt 1 and Dale R. Brogan 2 ABSTRACT Delano-Earlimart Irrigation District (DEID) delivers water through closed reinforced concrete pipelines

More information

EXHIBIT B. Notice of Non-Compliance

EXHIBIT B. Notice of Non-Compliance Page 1 of 6 EXHIBIT B Town of Flower Mound Large Residential and Commercial Water Meter Installation Policy 3-6 Compound or HP Turbine Meters Or 2 Compound Meter (06/20/05) The Town of Flower Mound has

More information

RESOURCE CONSENT CRC174931

RESOURCE CONSENT CRC174931 RESOURCE CONSENT CRC174931 Pursuant to Section 104 of the Resource Management Act 1991 The Canterbury Regional Council (known as Environment Canterbury) GRANTS TO: A WATER PERMIT (S14): Gary Thomas Tomes

More information

Contour K5 Technical Information

Contour K5 Technical Information Contour K5 Technical Information 45.00 Y Design Time Line, Flow Test Data and Information Supporting AGA-3 / API 14.3 (2000 Edition) Compliance 22.50 Ø 0.500D Ø 0.850D X FLANGE FACE SERRATED SPIRAL FINISH

More information

A M E M B E R O F T H E K E N D A L L G R O U P

A M E M B E R O F T H E K E N D A L L G R O U P A M E M B E R O F T H E K E N D A L L G R O U P FLOW METER DIAGNOSTICS, WORKING ON LIVE INSTRUMENTS Trouble-shooting installation issues such as noise, air entrainment, low conductivity, grounding, improper

More information

CIRRUS MAGNETIC FLOW METER CLA1-MF

CIRRUS MAGNETIC FLOW METER CLA1-MF CLA1-MF CLA1-MF MAGNETIC FLOW METER DESCRIPTION CLA1-MF Electromagnetic flow meters as they are called, operates on Faraday's law of electromagnetism to measure flow of conductive liquids. These flow meters

More information

Flow Measurement Structure Assessment

Flow Measurement Structure Assessment Flow Measurement Structure Assessment Report prepared for the Richmond Irrigation District by Eric Leigh, Milton Henry, and Guy Fipps 1 June 2, 2003 Summary Extension Agricultural Engineering investigated

More information

New Electronic Billing Meter Standards Shocking Utilities & Customers

New Electronic Billing Meter Standards Shocking Utilities & Customers North American Water Loss Conference 2017 New Electronic Billing Meter Standards Shocking Utilities & Customers Veolia North America December 4, 2017 PAGE 2 Purpose of today s presentation Overview Setting

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Introduction Modular design in two versions: Compact, sensor and electronics unit forming a single unit Separate, sensor and electronics separated, joined by a cable

More information

ENERGY USE FOR MICRO-IRRIGATION. Tom Trout and Jim Gartung 1 ABSTRACT INTRODUCTION

ENERGY USE FOR MICRO-IRRIGATION. Tom Trout and Jim Gartung 1 ABSTRACT INTRODUCTION ENERGY USE FOR MICRO-IRRIGATION Tom Trout and Jim Gartung 1 ABSTRACT Micro-irrigation systems can operate with low pressure. Micro-irrigation emitters require only 7-20 psi. Cleaning and delivering the

More information

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA METER SELECTION FOR VARIOUS LOAD REQUIREMENTS Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX 78238-5166 USA INTRODUCTION This paper is intended to provide meter station

More information

Appendix 6: Choosing the Right Turbine

Appendix 6: Choosing the Right Turbine Appendix 6: Choosing the Right Turbine A graphical representation of the power output of the hydro turbines in our product line is shown below. Once you have determined your site s head, flow, and your

More information

Gilflo flowmeters. for steam, liquids and gases

Gilflo flowmeters. for steam, liquids and gases Gilflo flowmeters for steam, liquids and gases The Gilflo spring loaded variable area flowmeter... offers an unrivalled 1:1 turndown and can be used to meter most industrial fluids including steam and

More information

Are Juvenile Chinook Salmon Entrained at Unscreened Diversions in Direct Proportion to the Volume of Water Diverted?

Are Juvenile Chinook Salmon Entrained at Unscreened Diversions in Direct Proportion to the Volume of Water Diverted? Are Juvenile Chinook Salmon Entrained at Unscreened Diversions in Direct Proportion to the Volume of Water Diverted? Charles H. Hanson Abstract Mark-recapture experiments were used to test the null hypothesis

More information

VLM10 In-line Vortex Mass Flow Meter

VLM10 In-line Vortex Mass Flow Meter VLM10 In-line Vortex Mass Flow Meter Description The VLM10 in-line vortex flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process

More information

DRAFT TECHNICAL MEMORANDUM

DRAFT TECHNICAL MEMORANDUM Stetson Engineers, Inc. Technical Memorandum - New City of Solvang Well Field, May 14, 2010 DRAFT TECHNICAL MEMORANDUM 2171 E. Francisco Blvd., Suite K San Rafael, California 94901 TEL: (415) 457-0701

More information

Presentation Overview

Presentation Overview Presentation Overview 1. Who is Hoffer Flow Controls? 2. Show me the money (benefits)! 3. Aren t t there other flowmeters that are better? 4. How Hoffer flowmeters can help you. 1 Hoffer has supplied flowmeters

More information

County Service Area 16 Shandon Water Rate Analysis

County Service Area 16 Shandon Water Rate Analysis County Service Area 16 Shandon Water Rate Analysis Prepared By: County Public Works December 2014 December 2014 Water Rate Analysis County Service Area (CSA) 16 Shandon, Water System Purpose The purpose

More information

Michael Cahn, Barry Farrara, Tim Hartz, Tom Bottoms, and Mark Bolda

Michael Cahn, Barry Farrara, Tim Hartz, Tom Bottoms, and Mark Bolda Strawberry water use on the Central Coast Michael Cahn, Barry Farrara, Tim Hartz, Tom Bottoms, and Mark Bolda With few options for importing water from other areas of the state, water supplies on the Central

More information

The Fluid Journal Offi cial Journal of the Fluid Fertilizer Foundation Early Spring 2013 Vol. 21, No. 2, Issue # 80

The Fluid Journal Offi cial Journal of the Fluid Fertilizer Foundation Early Spring 2013 Vol. 21, No. 2, Issue # 80 Chemigation Uniformity Critical Through Microirrigation System If done properly, injected chemical application will be as uniform as the water application. The Fluid Journal Offi cial Journal of the Fluid

More information

Section 7 Design Criteria Irrigation and Drainage Facilities

Section 7 Design Criteria Irrigation and Drainage Facilities Section 7 Design Criteria Irrigation and Drainage Facilities 7.1 Background The Irrigation and Drainage system is comprised of the Coachella Branch of the All-American Canal (Coachella Canal), Protective

More information

Gilflo ILVA flowmeters for steam, liquids and gases

Gilflo ILVA flowmeters for steam, liquids and gases Gilflo ILVA flowmeters for steam, liquids and gases The Gilflo in-line variable area (ILVA) flowmeter... is a revolutionary development of the well established family of Gilflo flowmeters that has been

More information

Education. V. Know How to Maintain an Efficient Pump. Pump Efficiency Tests. What is a Pump Test? Who Does the Pump Testing?

Education. V. Know How to Maintain an Efficient Pump. Pump Efficiency Tests. What is a Pump Test? Who Does the Pump Testing? V. Know How to Maintain an Efficient Pump There are at least four important aspects of maintaining an efficient pumping plant: 1. Initial specification and installation of the pumping plant. 2. Ensuring

More information

SUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM. By James T. Mailloux

SUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM. By James T. Mailloux SUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM By James T. Mailloux Submitted to FABCO INDUSTRIES, INC. June 2005 ALDEN RESEARCH LABORATORY, INC. 30 Shrewsbury

More information

Flow Measurement for Structure Assessment in Richmond Irrigation District

Flow Measurement for Structure Assessment in Richmond Irrigation District COLLEGE OF AGRICULTURE AND LIFE SCIENCES TR-379 2011 Flow Measurement for Structure Assessment in Richmond Irrigation District By: Eric Leigh, Extension Associate; Milton Henry, Graduate Assistant; and

More information

Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy

Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy E313 Effects of Pipe Wall Offsets on Differential Pressure Meter Accuracy JESSE M. POPE, 1 STEVEN L. BARFUSS, 2 MICHAEL C. JOHNSON, 2 AND ZACHARY B. SHARP 3 1 Gannett Fleming Inc., Camp Hill, Pa. 2 Utah

More information

DEPARTMENT OF CIVIL ENGINEERING CE6403/ APPLIED HYDRAULIC ENGINEERING QUESTION BANK TWO MARKS UNIT I UNIFORM FLOW 1. Differentiate open channel flow from pipe flow. 2. What is specific energy and is the

More information

Case Study: Flow Measurement and Control in Walker River Irrigation District

Case Study: Flow Measurement and Control in Walker River Irrigation District Case Study: Flow Measurement and Control in Walker River Irrigation District Sierra Layous, P.E., 1 Stuart Styles, P.E., D.Engr., M. ASCE, 2 and Robert Bryan 3 1 Senior Engineer, Irrigation Training and

More information

MODERNIZING IRRIGATION FACILITIES AT SUTTER MUTUAL WATER COMPANY: A CASE STUDY ABSTRACT

MODERNIZING IRRIGATION FACILITIES AT SUTTER MUTUAL WATER COMPANY: A CASE STUDY ABSTRACT MODERNIZING IRRIGATION FACILITIES AT SUTTER MUTUAL WATER COMPANY: A CASE STUDY Frederick F. Schantz 1, Stuart W. Styles 2, Beau J. Freeman 3, Charles M. Burt 4, Douglas Stevens 5 ABSTRACT In 1999 Sutter

More information

REQUIRED CONTROLS. One (1) well per 80 acres in Very High Risk area. Domestic Well Protection:

REQUIRED CONTROLS. One (1) well per 80 acres in Very High Risk area. Domestic Well Protection: Out of the BLUE APRIL 2014 LBNRD APPROVES NEW GROUNDWATER RULES The Little Blue NRD Board of Directors took action at their April 8, 2014 board meeting to approve new rules for managing groundwater in

More information

SCS-AMM15 : ADMIX SHOTCRETE MEASUREMENT SYSTEM

SCS-AMM15 : ADMIX SHOTCRETE MEASUREMENT SYSTEM SCS-AMM15 : ADMIX SHOTCRETE MEASUREMENT SYSTEM Congratulations on choosing a ManuFlo (Manu Electronics) liquid admixture magflow shotcrete measurement system. You will now join many thousands of satisfied

More information

Case Study: West Stanislaus Irrigation District Modernization

Case Study: West Stanislaus Irrigation District Modernization Case Study: West Stanislaus Irrigation District Modernization Kyle Feist, M.S., P.E. 1, Charles Burt, Ph.D., P.E 2 and Robert Pierce, M.S., P.E. 3 1 Irrigation Support Engineer. Irrigation Training and

More information

BACKFLOW PREVENTION ASSEMBLY INSTALLATION STANDARDS

BACKFLOW PREVENTION ASSEMBLY INSTALLATION STANDARDS Revised May 2014 BACKFLOW PREVENTION ASSEMBLY INSTALLATION STANDARDS All backflow prevention assembly installation shall be in accordance with the following Standards unless otherwise directed or approved

More information

The World Market for Magnetic Flowmeters, 4 th Edition Proposal

The World Market for Magnetic Flowmeters, 4 th Edition Proposal The World Market for Magnetic Flowmeters, 4 th Edition Proposal Publication Date: February 2009 2 Flow Research, Inc. 27 Water Street Wakefield, MA 01880 (781) 245-3200 (781) 224-7552 (fax) www.flowresearch.com

More information

Madera Irrigation District

Madera Irrigation District Madera Irrigation District Mission Statement THE MISSION OF MADERA IRRIGATION DISTRICT is to obtain and manage affordable surface water and groundwater supplies in a manner which will ensure the long-term

More information

Irrigation Efficiency, Uniformity & Crop Response. System performance evaluation

Irrigation Efficiency, Uniformity & Crop Response. System performance evaluation Irrigation Efficiency, Uniformity & Crop Response System performance evaluation Email: fcasselss@csufresno.edu Crop Water Stress Conference February 23, 2016 Florence Cassel S. Bill Green Assessing Irrigation

More information

CHEMIGATION & FERTIGATION:

CHEMIGATION & FERTIGATION: Revised August, 2003 Now includes fertigation CHEMIGATION & FERTIGATION: ANTI-POLLUTION DEVICES FOR IRRIGATION SYSTEMS Chemigation: The application of pesticides through an irrigation system to land, crops,

More information

Improved Flow Monitoring for Process Efficiency Improvements through New Technology Utilizing Non-Invasive Passive Arrays

Improved Flow Monitoring for Process Efficiency Improvements through New Technology Utilizing Non-Invasive Passive Arrays Improved Flow Monitoring for Process Efficiency Improvements through New Technology Utilizing Non-Invasive Passive Arrays Christian O Keefe CiDRA Minerals Processing, Wallingford, CT, USA Robert Maron

More information

EL DORADO IRRIGATION DISTRICT

EL DORADO IRRIGATION DISTRICT EL DORADO IRRIGATION DISTRICT Per Administrative Regulation 5021 Cross-Connection Control and Prevention of Backflow Program Prepared by Environmental Division of the Engineering Department Revised November

More information

T Series. Self-Priming Centrifugal Pumps

T Series. Self-Priming Centrifugal Pumps T Series Self-Priming Centrifugal Pumps The World Leader in Solids Handling Self-Priming Pumps. When industry looks for more reliable and efficient ways to move waste, they look to Gorman-Rupp self-priming

More information

s the costs of fuels and consumables to rise, the ability to accurately measure the amount used in a process becomes significant

s the costs of fuels and consumables to rise, the ability to accurately measure the amount used in a process becomes significant FLOW METER SELECTION FOR IMPROVED GAS FLOW MEASUREMENTS A The proper selection of a flow meter for measuring the amount of gas consumed in a process can be challenging. Know the type of technology that

More information

Rosemount 405 Compact Orifice Primary Element

Rosemount 405 Compact Orifice Primary Element Rosemount 405 Compact Orifice Primary Element SPECIFICATIONS Performance Discharge Coefficient Uncertainty TABLE 20. 405 Compact Orifice Primary Element Type 405C (Conditioning Compact) 405P (1)(2) (Standard

More information

ITRC METRIC and Net Groundwater Use/Recharge

ITRC METRIC and Net Groundwater Use/Recharge ITRC METRIC and Net Groundwater Use/Recharge Dan Howes, Ph.D., P.E. 9/5/2018 Irrigation Training and Research Center (ITRC) California Polytechnic State University (Cal Poly) San Luis Obispo, CA 93407

More information

Screening, Definition: The unit involved is called a screen.

Screening, Definition: The unit involved is called a screen. Screening, Definition: Screening is a unit operation that separates materials in and/or on water (found in different sizes) from water and from entering water treatment facilities and mains. The unit involved

More information

Choosing The Correct Flow Meters For Hydraulic Fracturing

Choosing The Correct Flow Meters For Hydraulic Fracturing WHITE PAPER Choosing The Correct Flow Meters For Hydraulic Fracturing INTRODUCTION Hydraulic Fracturing requires accurate and durable flow meters to monitor several processes during a fracking treatment.

More information

Impacts of Competing Water Demands on Irrigation Districts in California, USA. Chung-te Dick Tzou FAO, Bangkok, Thailand

Impacts of Competing Water Demands on Irrigation Districts in California, USA. Chung-te Dick Tzou FAO, Bangkok, Thailand Impacts of Competing Water Demands on Irrigation Districts in California, USA Chung-te Dick Tzou FAO, Bangkok, Thailand Is there enough water for everyone? Competing interests for water in California Urban

More information

NOTICE OF DISCONTINUATION,

NOTICE OF DISCONTINUATION, Sizes ", ", ", 6", 8", " NOTICE OF DISCONTINUATION, Effective May st Mueller Systems is discontinuing our current line of strainers. We will continue to offer our plate strainers on a first come, first

More information

ABB Measurement & Analytics Flowmeter technologies

ABB Measurement & Analytics Flowmeter technologies ABB MEASUREMENT & ANALYTICS TECHNICAL PUBLICATION ABB Measurement & Analytics Flowmeter technologies Selecting flowmeter technologies to minimize annual energy costs. by Paul Gibson DP Flow Global Product

More information

Sustainable Technology Park at California Polytechnic State University San Luis Obispo. Handbook of Guidelines : Ecology meets Technology

Sustainable Technology Park at California Polytechnic State University San Luis Obispo. Handbook of Guidelines : Ecology meets Technology Sustainable Technology Park at California Polytechnic State University San Luis Obispo Handbook of Guidelines : Ecology meets Technology Sam Vigil Professor of Environmental Engineering, Civil and Environmental

More information

Water flow measurement in the oil and gas industry

Water flow measurement in the oil and gas industry Water flow measurement in the oil and gas industry The importance of selection Proper selection of the flow technology Why is it important In oil and gas we are seeing a drop in crude prices and the biggest

More information