1 NJCAT TECHNOLOGY VERIFICATION Kraken Membrane Filtration System Bio Clean Environmental Services, Inc. (With April 2016 Addendum) February, 2016

2 Table of Contents Page Table of Contents... i List of Figures... ii List of Tables... ii 1. Description of Technology Laboratory Testing Test Setup Test Sediment Removal Efficiency Testing Sediment Mass Loading Capacity Scour Testing Performance Claims Supporting Documentation Removal Efficiency Testing Sediment Mass Loading Capacity Filter Driving Head Design Limitations Maintenance Plans Statements References...35 Verification Appendix...36 Addendum...42 i

3 List of Figures Page Figure 1 Kraken Design... 1 Figure 2 Kraken Filter KF Figure 3 Test Flow Loop... 3 Figure 4 Test Flow Loop Detail... 3 Figure 5 Background Sampling Point... 4 Figure 6 Effluent Sampling Removal Efficiency Test... 5 Figure 7 Sediment Addition Point... 6 Figure 8 Average Particle Size Distribution of Test Sediment... 7 Figure 9 Removal Efficiency vs Sediment Mass Loading for the Kraken KF Figure 10 Increase in Driving Head vs Sediment Mass Loading List of Tables Page Table 1 Particle Size Distribution of Test Sediment... 7 Table 2 Removal Efficiency Sampling Frequency... 8 Table 3 Removal Efficiency Water Flow Rate Table 4 Removal Efficiency Sediment Feed Rate Table 5 Removal Efficiency Drain Down Losses Table 6 Removal Efficiency SSC Data Table 7 Removal Efficiency Results Table 8 Sediment Mass Loading Water Flow Rate Table 9 Sediment Mass Loading Sediment Feed Rate Table 10 Sediment Mass Loading Drain Down Loses Table 11 Sediment Mass Loading SSC Data Table 12 Sediment Mass Loading Removal Efficiency Results ii

4 1. Description of Technology The Kraken Filter is an engineered storm water quality treatment device utilizing a reusable membrane filter designed to remove high levels of TSS, hydrocarbons, and particulate bound metals and nutrients found in contaminated storm water. Each filter contains a large surface area which is designed to deal with high TSS concentrations. The Kraken Filter has sedimentation chambers that are utilized as a form of pre-treatment for floatables, oils, coarser sediments and other suspended particulates. Once the water exits the pretreatment chamber, it passes through the filter chamber orifices and into the filtration chambers where the membrane filters are located. The membrane filters are used to filter out finer micron sediments and particulate bound contaminants. The filter s efficiency is controlled by an internal riser tube so the filters will only begin to process and discharge once the water level has reached to the top of the filter column, close to the maximum hydraulic grade line in the filtration chamber. The riser tubes control the flow rate to a level substantially less than the flow capacity of the membrane filters and ensure that the sediment loading is evenly distributed along the full height of the cartridge. Each filter chamber includes one drain down cartridge which has an additional small drain orifice at the bottom of the tube to allow the chambers to drain dry after each storm event. Since the standard cartridges have risers, there is no positive pressure on the influent side of the filter membrane during the drain down period, thereby allowing sediment which has accumulated on the surface of the membrane to be flushed off. The Kraken Filter is also designed with an internal bypass weir. The bypass weir is located at the effluent end of the pre-treatment chamber and allows runoff to pass directly from pre-treatment chamber to discharge chamber without passing through the filtration chambers. Water passes over the bypass weir once incoming flow exceeds the system s treatment capacity. This prevents scouring of fine sediment captured in the filtration chambers. Figure 1 shows a cut-away view of the system s pre-treatment, filtration and discharge chambers. Figure 1 Kraken Design 1

5 2. Laboratory Testing The test program was conducted by Good Harbour Laboratories, an independent water technology testing lab, at their site in Mississauga, Ontario. Testing occurred during the month of August, The Kraken Filter that was tested in the laboratory was identical to a commercially available unit with the exception that it did not have a concrete top that would be associated with a unit installed below grade. For lab testing there was no need for a concrete top as it would inhibit access to the unit. There was no effect on testing by not having a top on the unit. Laboratory testing was done in accordance with the New Jersey Department of Environmental Protection Laboratory Protocol to Assess Total Suspended Solids Removal by a Filtration Manufactured Treatment Device (January, 2013). Prior to starting the performance testing program, a quality assurance project plan (QAPP) was submitted to and approved by the New Jersey Corporation for Advanced Technology (NJCAT). 2.1 Test Setup The Kraken Filter tested was a commercially available Membrane Filtration System, model KF- 4-4, dimensional details are provided in Figure 2. This unit has a total sedimentation area of ft 2 and 16 filters, providing an effective filtration treatment area of 2720 ft 2. The KF-4-4 model enables the results to be scaled to all other Kraken Filter Models (Table A-3). Figure 2 Kraken Filter KF-4-4 The laboratory test setup was a water flow loop filled with potable water. The loop was comprised of water reservoirs, pumps, stand pipe, receiving tank and flow meters, in addition to the Kraken 2

6 Filter. The total water capacity of the system was approximately 10,000 gallons. The test flow loop is illustrated in Figure 3 and Figure 4. Inlet Reservoir 8 Water Supply Line Recirculation Line Outlet Reservoir Effluent Sample Point Kraken Filter Auger Feeder Influent Sample Point Standpipe Receiving Tank To Waste Figure 3 Test Flow Loop Auger Feeder Effluent Sample Point 30 Kraken Filter (3% Slope) Influent Sample Point 10 Pipe Standpipe Receiving Tank Water Flow and Measurement Figure 4 Test Flow Loop Detail From the inlet reservoir, water was pumped using a WEG Model FC00312 centrifugal pump through a 3ʺ PVC line to the standpipe. Flow measurement was done using a Toshiba Model GF630 mag-type flow meter and a MadgeTech Process 101A data logger. The data logger was configured to record a flow measurement every minute. 3

7 From the standpipe, water flowed by gravity through a 10ʺ inlet pipe to the Kraken Filter. The influent pipe was 148 inches long with a slope of 3%. Water flow exited the Kraken Filter through a 10ʺ pipe stub (30 inches long) and terminated with a free-fall into the Receiving Tank. From the Receiving Tank, water was either pumped to waste or into the Outlet Reservoir. Sample Collection Background water samples were grabbed by hand by submerging a 1L sample jar beneath the surface of the water in the stand pipe, at the mouth of the influent feed line (Figure 5). Background Sampling Point To Kraken Standpipe Figure 5 Background Sampling Point Effluent samples for the Removal Efficiency and Sediment Mass Loading tests were also grabbed by hand. The effluent pipe drained freely into the Receiving Tank and the effluent sample was 4

8 taken at that point (Figure 6). The sampling technique was to take the grab sample by sweeping a wide-mouth 1L jar through the entire stream such that the sample jar was full after a single pass. Figure 6 Effluent Sampling Removal Efficiency Test Other Instrumentation and Measurement Effluent water temperature was taken at the end of the effluent pipe, as the flow discharged into the Receiving Tank, using a Kangaroo Model digital thermometer. The water level in the Kraken Filter during the run was taken in the Secondary Sedimentation Chamber against the baffle wall, next to the bypass weir. Measurements were taken using a yard stick with 1/8ʺ resolution. A second yard stick was also set up in one of the filtration chambers to allow for the calculation of the water volume during drain down. Run and sampling times were measured using a stopwatch (Control Company Model X4C50200C). Sediment addition occurred through the crown of the inlet pipe, 35 inches (3.5 pipe diameters) from the Kraken Filter inlet (Figure 7). The sediment feeder was an Auger Feeders Model VF- 1 volumetric screw feeder with a 5/8ʺ or 7/8ʺ auger, spout attachment and 1.5 cubic foot hopper. The sediment feed samples that were taken during the run were collected in 500 ml jars and weighed on an analytical balance (Mettler Toledo Model AB204-S). 5

9 Figure 7 Sediment Addition Point 2.2 Test Sediment The test sediment used for this study was a custom blend of two commercially available silica sediments. The blend ratio was determined such that the particle size distribution of the resulting blended sediment would meet the specification for the Filter Test Protocol. The sediment was blended using a small cement mixer in nine batches. Following each batch, 2 X 30 ml sediment samples were placed in each of three 1 L jars, the samples were taken from random positions throughout the cement mixer. When blending was complete, each sample jar contained 540 ml of sediment. The blended sediment was stored in sealed plastic-lined fiber drums until needed. The three sediment samples were sent to Maxxam Analytical in Mississauga ON for particle size analysis using the methodology of ASTM method D The test results are summarized in Table 1 and shown graphically in Figure 8. 6

10 % Passing Particle Size (µm) Table 1 Particle Size Distribution of Test Sediment Test Sediment Particle size (%passing) Sample 1 Sample 2 Sample 3 Average NJDEP Specification ( minimum % Passing) Test Sediment NJDEP Specification Particle Size, µm 10 1 Figure 8 Average Particle Size Distribution of Test Sediment 7

11 In addition to particle size distribution, Maxxam Analytics also performed a moisture analysis of the test sediment and determined the water content to be < 0.30%, the method detection limit. The blended test sediment was found to meet the NJDEP particle size specification and was acceptable for use. With a d50 of 52 µm, the test sediment was slightly finer than the sediment required by the NJDEP test protocol. 2.3 Removal Efficiency Testing Removal Efficiency Testing was conducted in accordance with Section 5 of the NJDEP Laboratory Protocol for Filtration MTDs. Testing was completed at a flow rate of cfs (136 gpm) and a target sediment concentration of 200 mg/l. Effluent grab sampling was performed 5 times per run (at evenly spaced intervals), with each run lasting 45 minutes in duration followed by a drain down period. In addition to the effluent samples, 3 background water samples were taken with every odd-numbered effluent sample (1st, 3rd and 5th). In all cases, effluent sampling did not start until the filtration MTD had been in operation for a minimum of three detention times (5.4 minutes). When the test sediment feed was interrupted for measurement, the next effluent sample was collected following a minimum of three detention times. Sampling times for Removal Efficiency testing are summarized in Table 2. Effluent and background water samples were collected in clean 1L wide-mouth jars. The test sediment was sampled 3 times per run to confirm the sediment feed rate, one sample at the start of dosing, one sample in the middle of the test run and one sample just prior to the conclusion of dosing. Each sediment feed rate sample was a minimum of 100 ml and collected in a clean 500 ml jar. Sediment sampling was timed to the nearest 1/100 th of a second using a calibrated stop watch and samples were weighed to the nearest 0.1 mg. It was originally proposed that the water flow through the system would be a closed loop; the water would be recirculated from the Receiving Tank back into the Outlet Reservoir. However after the initial two runs of the Removal Efficiency Test, a concern arose over maintaining the background sediment concentration below 20 mg/l. Therefore, the system was modified so that the effluent was pumped from the Receiving Tank to waste and fresh potable make-up water was added to maintain the water level in the system. The water temperature was measured as the effluent exited the Kraken Filter with a calibrated thermometer to the nearest 0.1 C. Table 2 Removal Efficiency Sampling Frequency Sample/ Measurement Taken Run Time (min.) Sediment X X X Effluent X X X X X E N D of Background X X X R U N Drain down X X 8

12 The drain down sample was collected at the end of each removal efficiency run, after the pump had been switched off and the sediment feed stopped. On a clean filter, the drain down period lasted 15 minutes and sampling occurred at 5 and 10 minutes into the drain down period. However, as sediment accumulated in the filtration chambers, the drain down period was extended. Therefore the sampling period was also adjusted, gradually increasing to 10 and 20 minutes after the pump and sediment feed had stopped. 2.4 Sediment Mass Loading Capacity The sediment mass loading capacity of the Kraken Filter was determined as a continuation of the Removal Efficiency Testing. All aspects of the test procedure remained the same except that the influent sediment concentration was increased from 200 to 400 mg/l. Sediment Mass loading began after 16 runs of removal efficiency had been completed. 2.5 Scour Testing At this time the Kraken Filter System is being submitted for approval for off-line testing; therefore no scour test data was provided. 3. Performance Claims Per the NJDEP verification procedure, the following are the performance claims made by Bio Clean Environmental Services, Inc. and/or established via the laboratory testing conducted for the Kraken Filter. Verified Total Suspended Solids (TSS) Removal Rate Based on the laboratory testing conducted, the Kraken Filter achieved greater than 80% removal efficiency of TSS. In accordance with the NJDEP process for obtaining approval of a stormwater treatment device from NJCAT (Procedure; NJDEP 2013) the TSS removal efficiency is rounded down to 80%. Maximum Treatment Flow Rate (MTFR) and maximum drain down cartridge flow. The MTFR increases with the Kraken Filter model size and the number of filtration cartridges. For the tested unit, the Kraken Filter model KF-4-4, the MTFR was cfs (136 gpm) which corresponds to a MTFR to filtration treatment area ratio of 1.11x10-4 cfs/ft 2 (0.05 gpm/ft 2 ). Each Kraken Filter is designed so that there is 1 drain down cartridge for every 7 filter cartridges. The drain down flow is regulated by a drain down orifice, sized so that a clean filter drains down in 15 minutes. The drain down flow rate is expected to decrease as the filters ripen. Maximum Sediment Storage Depth and Volume The sedimentation and treatment volume varies with the Kraken Filter model size. For the KF- 4-4, the total storage capacity is 4.5 ft 3 (as determined during this laboratory testing), which includes the Primary Sedimentation, Secondary Sedimentation and two Filter chambers. 9

13 Effective Treatment/Sedimentation Area The Effective Treatment and Sedimentation areas are the same for the Kraken Filter and will increase with increasing model size. For the Kraken Filter KF-4-4, the effective treatment/sedimentation area is the combined area of all the chambers, ft 2. Detention Time and Wet Volume The Kraken Filter detention time and wet volume will vary with model size. The unit tested had a wet volume of 32 ft 3 which corresponded to a detention time of 1.8 minutes at the test flow rate of cfs. Effective Filtration Area The effective filtration area varies with the number of cartridges installed in the Kraken Filter unit. The KF-4-4 has 16 filters with a total effective filtration area of 2,720 ft 2. Sediment Mass Loading Capacity The sedimentation mass loading capacity varies with the Kraken Filter model size. Based on the laboratory testing results, the KF-4-4 has a mass loading capacity of 434 lbs. (4.5 ft 3 ). Maximum Allowable Inflow Drainage Area Based on the results from the laboratory testing, approximately 434 pounds of sediment (27.1 lbs/cartridge AND/OR 37 lbs/ft 2 of effective treatment/sedimentation area) can be loaded into the KF-4-4, while maintaining an overall 89% removal efficiency. Based on the protocol requirements for Maximum Allowable Inflow Drainage Area the KF-4-4 can effectively treat acres based on a load of 600 lbs per acre of drainage area annually per the protocol. It should be noted that at 434 pounds of sediment loading the system did not go into bypass. The water level in the system was still several inches from the bypass weir, indicating the system could continue to effectively treat runoff at cfs for an extended period of time. 4. Supporting Documentation The NJDEP Procedure (NJDEP, 2013) for obtaining verification of a stormwater manufactured treatment device (MTD) from the New Jersey Corporation for Advanced Technology (NJCAT) requires that copies of the laboratory test reports, including all collected and measured data; all data from performance evaluation test runs; spreadsheets containing original data from all performance test runs; all pertinent calculations; etc. be included in this section. This was discussed with NJDEP and it was agreed that as long as such documentation could be made available by NJCAT upon request that it would not be prudent or necessary to include all this information in this verification report. 10

14 4.1 Removal Efficiency Testing A total of 16 removal efficiency testing runs were completed in accordance with the NJDEP filter protocol. The target flow rate and influent sediment concentration were 136 gpm and 200 mg/l respectively. The results from all 16 runs were used to calculate the overall removal efficiency of the Kraken Filter KF-4-4. Flow Rate The flow rate was measured using an electromagnetic-type flow meter and data logger configured to take a reading every minute. The run was started as soon as water was observed to be exiting from the Kraken Filter. For each run, the flow rate was to be maintained within 10% of the target flow with a COV (coefficient of variation) of The flow data has been summarized in Table 3, including the compliance to the QA/QC acceptance criteria. The average flow for all removal efficiency runs was gpm. Sediment Addition The target sediment concentration was 200 ± 20 mg/l with a COV of The sediment feed rate for each run was checked three times during each run. The sediment weight checks, feed rates, final concentrations and compliance to QA/QC criteria are summarized in Table 4. Filter Drain Down The Kraken Filter is designed with a drain down feature that allows the filter chambers to drain dry after each storm event. The drain down permits sediment which has accumulated on the surface of the membrane to be flushed off thereby extending the life of the filters. As per the NJDEP protocol, the amount of sediment that escapes the filter during the drain period must be accounted for. The volume of water in the filter chambers was determined by multiplying the chamber area by the water level in the chamber at the end of the run. The water volume was corrected for the displacement volume of the filters. Effluent samples for total suspended solids (TSS), measured as suspended sediment concentration (SSC), determination were taken during the drain down period to permit estimation of the amount of sediment that was lost. 11

15 Run # Table 3 Removal Efficiency Water Flow Rate Flow (gpm) Min Max Average Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 16.6 Overall Average Flow COV gpm QA/QC Compliance (COV < 0.03) Maximum Water Temperature ( C) A clean Kraken Filter has a drain down period of approximately 15 minutes, so the initial drain down samples were taken at 5 and 10 minutes. As more sediment accumulated in the filter chambers, the drain down period was extended with the most substantial time increase occurring during the draining of the lower third volume fraction. The sampling times for the drain down samples were adjusted as the drain down period increased. For the purposes of conducting the NJDEP protocol, it was not practical to wait to start the next run. Therefore, runs were started even though the drain down process had not completed. Even though not all the water had drained from the filter chambers, the full filter chamber volume was used to estimate the amount of lost sediment. The sampling data for the drain down periods are presented in Table 5. For the majority of the runs, the drain down samples were taken at 10 and 20 minutes. It is clear from the sediment concentration results that the longer the time for the drain down sample, the lower the sample concentration. Therefore, not extending the sampling time beyond 10 and 20 minutes was a worst case scenario. 12

16 Run # Run Time (min) Weight (g) Duration (s) *Based on the run average water flow rate Feed Rate (g/min) Table 4 Removal Efficiency Sediment Feed Rate Sediment Concentration* (mg/l) QA/QC Compliance (COV < 0.1) Run # Run Time (min) Weight (g) Duration (s) Feed Rate (g/min) Sediment Concentration* (mg/l) Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV QA/QC Compliance (COV < 0.1) 13

17 Table 5 Removal Efficiency Drain Down Losses Run # Water Level at End of Run (inches) Total Water Volume (L) Time of Sample (min. from end of run) Sediment Concentration (mg/l) Average Concentration (mg/l) Lost Sediment (g) / / / / / / / / / /

18 Removal Efficiency Calculations All of the effluent and background samples for SSC were analysed by Maxxam Analytics of Mississauga ON, the results have been summarized in Table 6. The required background SSC concentration was < 20mg/L. The limit of detection for the analytical method was 1 mg/l. For the purposes of calculation, any result that was reported as being below the limit of detection (ND), was assigned a value of ½ the detection limit or 0.5 mg/l. The adjusted average sediment concentration was determined by: Average effluent concentration Average background concentration Table 6 Removal Efficiency SSC Data Run # 1* 2* QA/QC Suspended Sediment Concentration, SSC Compliance (Background Run Time (min.) Average < 20 mg/l) Background Yes Effluent N/A 39 Background Yes Effluent N/A 34 Effluent N/A 42 Effluent N/A 38 Effluent N/A 38 Effluent N/A 40 Effluent N/A 49 ND non-detect * Due to a communication error with the analytical lab, the sample container washout was not included as part of the sample analysis. This error only applies to Runs #

19 Table 6 Removal Efficiency SSC Data (Cont d) Run # Suspended Sediment Concentration, SSC QA/QC Compliance Run Time (min.) Average (Background < 20 mg/l) Background ND - ND Yes Effluent N/A 33 Effluent N/A 33 Effluent N/A 38 Effluent N/A 30 Effluent N/A 31 Effluent N/A 28 Effluent N/A 26 Effluent N/A 22 Effluent N/A 18 ND non-detect The analytical results, along with the run data, were used to calculate the removal efficiency for each run, mass loading and overall removal efficiency average; the results are tabulated in Table 7. The removal efficiency was calculated as: 16

20 Removal Efficiency (%) = Average Average Influent Adjusted Effluent Draindown Flow SS Concentration X SS Concentration X ( ) ( ) SS Concentration X Total Volume Total Volume Total Volume of Test Water of Test Water ( of Draindown Water) 100 Average Influent SS Concentration X Total Volume of Test Water Run # Average Influent SSC Adjusted Effluent SSC Table 7 Removal Efficiency Results Total Water Volume Average Drain Down SSC Volume of Drain Down Water Removal Efficiency Mass of Captured Sediment (mg/l) (mg/l) gal (mg/l) gal (%) (lbs.) Average Removal Efficiency 83% Captured Sediment Mass 127 lbs. The results are typical for membrane filters in that the removal efficiency increases as the filters begin to ripen. The overall average removal efficiency was 83% for the first 16 runs. Runs #1 and 2 were included in the calculation of the average result, despite the error for the sample analysis indicated on the previous page. If these runs were excluded, there would be no change in the average result. During the Removal Efficiency testing, 127 pounds of sediment was captured in the Kraken Filter. 4.2 Sediment Mass Loading Capacity The Sediment Mass Loading Capacity study was a continuation of the removal efficiency study. All aspects of the testing remained the same, except that the feed concentration was increased to 400 mg/l, up from the 200 mg/l used for the removal efficiency test. To achieve the higher sediment feed rate, the 7/8ʺ auger screw was used. An additional 17 runs were completed for Sediment Mass Loading Capacity testing for a total of 33 runs overall. For Runs 17 33, the mass loading water flow rates, sediment feed rates, drain down loses, SSC data and removal efficiencies are presented in Table 8 to Table 12 respectively. 17

21 Removal Efficiency (%) The Sediment Mass Loading Capacity test was terminated once the mass of the captured sediment exceeded 1.5X the recommended minimum amount for filter maintenance. By the end of run #33, filter by-pass had not yet occurred. The total mass of sediment captured was 434 lbs. and the overall removal efficiency was 89%. The relationship between removal efficiency and sediment mass loading is illustrated in Figure 9. Figure 9 Removal Efficiency vs Sediment Mass Loading for the Kraken KF Sediment Mass Load (lbs.) 4.3 Filter Driving Head The filter chambers, which drain down in between storm events, have been designed with riser tubes that maintain the hydraulic grade line at a minimum level during operation. The water level in the filter chambers at the end of each run, prior to drain down, has been tabulated in Tables 5 and 10. The reported level is the distance from the floor of the filter chamber. Figure 10 illustrates the increase in driving head across the filters compared to the initial hydraulic grade line of 27 inches. 18

22 Figure 10 Increase in Driving Head vs Sediment Mass Load 19

23 Table 8 Sediment Mass Loading Water Flow Rate Run # Flow (gpm) Min Max Average COV QA/QC Compliance (COV < 0.03) Maximum Water Temperature ( C) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 18.0 Overall Average Flow (Runs 1-33) gpm 20

24 Table 9 Sediment Mass Loading Sediment Feed Rate Run # Run Time (min) Weight (g) Duration (s) Feed Rate (g/min) Sediment Concentration* (mg/l) QA/QC Compliance (COV < 0.1) Run # Run Time (min) Weight (g) Duration (s) Feed Rate (g/min) Sediment Concentration* (mg/l) Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Yes Average Average COV COV Yes Average COV QA/QC Compliance (COV < 0.1) *Based on the run average water flow rate 21

25 Table 10 Sediment Mass Loading Drain Down Loses Run # Water Level at End of Run (inches) Total Water Volume (L) Time of Sample (min. from end of run) Sediment Concentration (mg/l) Average Concentration (mg/l) Lost Sediment (g) / / / / / / / / / / / / / / / / /

26 Table 11 Sediment Mass Loading SSC Data Run # Suspended Sediment Concentration, SSC QA/QC Compliance Run Time (min.) Average Effluent N/A 48 Effluent N/A 42 Effluent N/A 36 Effluent N/A 49 Effluent N/A 30 Effluent N/A 32 Effluent N/A 33 Effluent N/A 21 Effluent N/A 20 Effluent N/A 15 Effluent N/A 26 Effluent N/A 12 ND non-detect 23

27 Table 11 Sediment Mass Loading SSC Data (Cont d) Run # Suspended Sediment Concentration, SSC QA/QC Compliance Run Time (min.) Average Effluent N/A 12 Effluent N/A 14 Effluent N/A 15 Effluent N/A 8 Effluent N/A 9 ND non-detect Run # Average Influent SSC Table 12 Sediment Mass Loading Removal Efficiency Results Adjusted Effluent SSC Total Water Volume Average Drain Down SSC Volume of Drain Down Water Removal Efficiency Mass of Captured Sediment (mg/l) (mg/l) Gal (mg/l) gal (%) (lbs.) Overall Average Removal Efficiency (Runs 1-33) 89% Overall Captured Sediment Mass (Runs 1-33) lbs. 24

28 5. Design Limitations Bio Clean Environmental Services, Inc. provides engineering support to clients on all projects. Each system prior to submittal is evaluated and properly designed/sized to meet site specific conditions including treatment and bypass flow rates, load rating requirements, and pipe depth. All site and design constraints will be addressed during the design and manufacturing process. Required Soil Characteristics The Kraken Filter is delivered to the job site as a complete pre-assembled unit housed in a concrete structure designed to meet site specific soil conditions, corrosiveness, top and lateral loading, and ground water. The system can be used in all soil types. A copy of the geotechnical report along with surface loading requirements are reviewed and verified for each project. Slope The Kraken Filter is most commonly used in a piped-in configuration in which one or more pipes enter the side of the system subsurface. In general, it is not recommended that the pipe slope into the system exceed 10% nor be less than 0.5%. Slopes higher than 10% will cause increased velocities which could affect the performance of the pre-treatment chamber. Slopes less than 0.5% could cause sediment to accumulate in the bottom of the inflow pipe and affect its hydraulic capacity. The Kraken Filter is usually not affected by variations in slope of the finish surface as the unit is buried underground. Risers of various heights can be used to bring access to the system up to finish surface. In some configurations the Kraken Filter can be installed with a built-in curb or drop inlet. In these configurations finish surface slope is more constrained and will require design review to ensure appropriate configuration. Maximum Flow Rate Maximum treatment flow rate is dependent on model size. The Kraken Filter will be sized based upon the NJCAT tested hydraulic loading rate of 0.05 gallons per minute per square foot filter membrane surface area. Section 6 includes details pertaining to inspection and maintenance of the Kraken Filter. Maintenance Requirements Requirements pertaining to maintenance of the Kraken Filter will vary depending on pollutant loading and individual site conditions. It is recommended that the system be inspected at least twice during the first year as a way to determine loading conditions for each site. These first year inspections can be used as a way to establish inspection and maintenance frequency for subsequent years. Driving Head Driving head will vary for a given Kraken Filter model based on the site specific configuration. Maximum treatment flow, maximum peak flow rate for online units, pipe slope and diameter will be assessed. At the conclusion of mass load testing the water level reached 29.5 inches. This should be used as the minimum driving head requirement for design. It is recommended that pipe fall between the inflow and outflow pipe be provided to minimize or eliminate the amount of surcharge required during lower flows. Bio Clean Environmental provides design support for each project. Site specific drawings (cut sheet) will be provided that show pipe inverts, finish surface 25

29 elevation, flow rates, and hydraulic grade lines. The hydraulic grade line will be assessed for its effect on the overall drainage system to ensure no flooding at peak flow. Installation Limitations With each installation Bio Clean Environmental provides contractors with instructions prior to delivery. Contractors can request onsite assistance from an installation technician during delivery and installation. Pick weights and lifting details are also provided prior to delivery so the contractor can prepare appropriate equipment onsite to set the unit. Configurations The Kraken Filter is available in various configurations. The units can be installed online or offline. However, this verification is for offline installation only. The Kraken Filter has an internal bypass weir (optional) which allows for it to be installed online without the need for any external high flow diversion structure. For online installations peak bypass flow is routed directly from pre-treatment chamber to discharge chamber, thus fully bypassing the filter chambers and preventing any scouring of captured pollutants. Structural Load Limitations The Kraken Filter is housed in a pre-cast concrete structure. Most standard structures are designed to handle indirect traffic loads with minimal cover. For deeper installation or installation requiring direct traffic rating or higher the structure will be designed and modified with potentially thicker tops, bottoms and/or walls to handle the additional loading. Various access hatch options are available for parkway, indirect traffic, direct traffic and other higher loading requirements such as airports or loading docks. Pre-treatment Requirements The Kraken Filter is designed with built-in pre-treatment capable of capturing sediments, debris and floatables such as trash and other materials. No other pre-treatment is required. Limitations in Tailwater Site specific tailwater conditions must be assessed on each individual project. Tailwater conditions increase the amount of driving head required for optimal system operation. The manufacturer s internal protocols require that these conditions are discussed with the engineer of record and that a solution be implemented to adjust for any design variations caused by tailwater conditions at both treatment and bypass flow rates. Depth to Seasonal High Water Table High groundwater conditions will not affect the operation of the Kraken Filter as it is a closed system. In conditions where high groundwater is present, various measures will be employed by Bio Clean Environmental s engineering department to ensure that there are no negative consequences caused by the high groundwater. Various measures can be employed such as waterproofing the inside and outside of the structure with an approved coating. A footing can also be added to the bottom of the structure to increase its footprint and offset any buoyancy concerns. 26

30 6. Maintenance Plans The Kraken Filter is designed at a loading rate of 0.05 gpm/ft 2 of media surface area to maximize longevity and minimize maintenance requirements. Passive backwash and pre-treatment also helps to minimize system maintenance requirements. The Kraken Filter has proven to handle at least 18 months sediment loading with no maintenance or loss of treatment capacity. As with all stormwater BMPs inspection and maintenance on the Kraken Filter is necessary. Stormwater regulations require that all BMPs be inspected and maintained to ensure they are operating as designed to allow for effective pollutant removal and provide protection to receiving water bodies. It is recommended that inspections be performed multiple times during the first year to assess site specific loading conditions. This is recommended because pollutant loading can vary greatly from site to site. Variables such as nearby soil erosion or construction sites, winter sanding of roads, amount of daily traffic and land use can increase pollutant loading on the system. The first year of inspections can be used to set inspection and maintenance intervals for subsequent years. Without appropriate maintenance a BMP can exceed its storage capacity which can negatively affect its continued performance in removing and retaining captured pollutants. The Kraken Filter Operation & Maintenance Manual is available at: Inspection Equipment Following is a list of equipment to allow for simple and effective inspection of the Kraken Filter: Bio Clean Environmental Inspection Form (contained in O&M Manual). Flashlight. Manhole hook or appropriate tools to access hatches and covers. Appropriate traffic control signage and procedures. Measuring pole and/or tape measure. Protective clothing and eye protection. Note: entering a confined space requires appropriate safety and certification. It is generally not required for routine inspections of the system. Inspection Steps The core to any successful stormwater BMP maintenance program is routine inspections. The inspection steps required on the Kraken Filter are quick and easy. As mentioned above the first year or two should be seen as the maintenance interval establishment phase. During the first two years more frequent inspections should occur in order to gather loading data and maintenance requirements for that specific site. This information can be used to establish a base for long term inspection and maintenance interval requirements. The Kraken Filter can be inspected though visual observation without entry into the system. All necessary pre-inspection steps must be carried out before inspection occurs, especially traffic control and other safety measures to protect the inspector and near-by pedestrians from any dangers associated with an open access hatch or manhole. Once these access covers have been safely opened the inspection process can proceed: 27

31 Prepare the inspection form by writing in the necessary information including project name, location, date & time, unit number and other info (see inspection form). Observe the inside of the system through the access hatches. If minimal light is available and vision into the unit is impaired utilize a flashlight to see inside the system and all of its chambers. Look for any out of the ordinary obstructions in the inflow pipe, pre-treatment chamber, filter chambers, discharge chamber or outflow pipe. Write down any observations on the inspection form. Through observation and/or digital photographs estimate the amount of floatable debris accumulated in the pre-treatment chamber. Record this information on the inspection form. Next utilizing a tape measure or measuring stick estimate the amount of sediment accumulated in the primary and secondary sedimentation chambers. Record this depth on the inspection form. Through visual observation inspect the condition of the filter cartridges. Look for excessive build-up of sediments on the surface and any build-up on the top of the cartridges. Record this information on the inspection form. Finalize inspection report for analysis by the maintenance manager to determine if maintenance is required. Maintenance Indicators Based upon observations made during inspection, maintenance of the system may be required based on the following indicators: Missing or damaged internal components or cartridges. Obstructions in the system or its inlet or outlet. Excessive accumulation of floatable in the pre-treatment chambers in which the length and width of the chambers behind oil/floatables skimmer is fully impacted. Excessive accumulation of sediment in the primary sedimentation chamber of more than 18 in depth. Excessive accumulation of sediment in the secondary sedimentation chamber of more than 6. Excessive accumulation of sediment in the filter chambers of more than 3 on average. Substantial build-up of sediments on the membrane of the filter cartridges which will have a very dark appearance indicating the membrane may be fully saturated with sediment. Maintenance Equipment While maintenance can be done fully by hand it is recommended that a vacuum truck be utilized to minimize the time required to maintain the Kraken Filter: Bio Clean Environmental Maintenance Form (contained in O&M Manual). Flashlight. Manhole hook or appropriate tools to access hatches and covers. Appropriate traffic control signage and procedures. Measuring pole and/or tape measure. Protective clothing and eye protection. Note: entering a confined space requires appropriate safety and certification. It is generally not required for routine inspections of the system. Entry into the system will be required if it is determine the cartridge filters need washing/cleaning. 28

32 Vacuum truck Trash can Pressure washer Maintenance Procedures It is recommended that maintenance occurs at least three days after the most recent rain event to allow for drain down of the system and any associated upstream detention systems. Maintaining the system while flows are still entering it will increase the time and complexity required for maintenance. Cleaning of the pre-treatment chamber can be performed from finish surface without entry into the vault utilizing a vacuum truck. Once all safety measures have been set up cleaning of the pre-treatment chamber can proceed as followed: Using an extension on a vacuum truck position the hose over the opened access hatch and lower into the center of the primary sedimentation chamber. Remove all floating debris, standing water and sediment from the chamber. A power washer can be used to assist if sediments have become hardened and stuck to the walls or the floor of the chamber. Repeat the same procedure for the secondary sedimentation chamber. This completes the maintenance procedure required on the pre-treatment chamber. If maintenance is required on the filter cartridges the following procedure can be followed after maintenance on the pre-treatment chamber is performed: Following rules for confined space entry use a gas meter to detect the presence of any hazardous gases. If hazardous gases are present do not enter the vault. Follow appropriate confined space procedures, such as utilizing venting system, to address the hazard. Once it is determined to be safe to enter utilize appropriate entry equipment such as a ladder and tripod with harness to enter the system. Once entry into the system has been established the maintenance technician should position themselves to stand in the pre-treatment chamber. From here the removal of the cartridges can commence. Each cartridge is pressure fitted in place and includes a handle for easy removal. To remove a cartridge, simply grab the handle and pull straight up. It may be required to gently shift pressure from side to side while pulling up to break the pressure seal. Removal of the cartridge should be done by hand with minimal effort and requires no tools. Once the cartridges are removed they should be taken out of the vault and brought up to finish surface for cleaning. Using a large garbage can and a standard garden hose (low pressure nozzle), each cartridge should be rinsed off from the outside to remove accumulated sediments and debris. Once each cartridge is rinsed it should be placed to the side for re-installation. Each filter chamber should be power washed and vacuumed clean before re-inserting the cleaned cartridges. After all cartridges have been washed they can be replaced back into the vault. To replace each cartridge simply slide the cartridge over each pressure fitted coupler. Push down on the handle to ensure the cartridge has been fully seated and the bottom of the cartridge is making contact with the floor. The last step is to close up and replace all access hatches and remove all traffic control. 29

33 All removed debris and pollutants shall be disposed of following local and state requirements. Disposal requirements for recovered pollutants and spent cartridges may vary depending on local guidelines. In most areas the sediment and spent cartridges, once dewatered, can be disposed of in a sanitary landfill. It is not anticipated that the sediment would be classified as hazardous waste. In the case of damaged components or spend cartridges, replacement parts can be ordered by the manufacture. 7. Statements The following attached pages are signed statements from the manufacturer (Bio Clean Environmental Services, Inc.), the independent test laboratory (Good Harbour Labs), and NJCAT. These statements are a requirement of the verification process. In addition, it should be noted that this report has been subjected to public review (e.g. stormwater industry) and all comments and concerns have been satisfactorily addressed. 30

34 31

35 32

36 Center for Environmental Systems Stevens Institute of Technology Castle Point on Hudson Hoboken, NJ December 10, 2015 Titus Magnanao NJDEP Division of Water Quality Bureau of Non-Point Pollution Control B PO Box 420 Trenton, NJ Dear Mr. Magnanao, Based on my review, evaluation and assessment of the testing conducted on the Kraken Membrane Filtration System by Good Harbour Laboratories, an independent technology testing laboratory, at their site in Mississauga, Ontario, Canada, the test protocol requirements contained in the New Jersey Department of Environmental Protection Laboratory Protocol to Assess Total Suspended Solids Removal by a Filtration Manufactured Treatment Device (NJDEP Filter Protocol, January 2013) were met or exceeded. Specifically: Test Sediment Feed Good Harbour used test sediment that was a blend of two commercially available silica sediments. The blended test sediment was found to meet the NJDEP particle size specification and was acceptable for use. With a d50 of 52 µm, the test sediment was slightly finer than the sediment required by the NJDEP test protocol. Removal Efficiency Testing A total of 16 test runs were conducted during removal efficiency testing. All of these test runs met the requirements of the Filter Protocol. The 16 test runs had an overall average removal efficiency of 83%. Sediment Mass Loading Capacity A total of 33 test runs were conducted at the MTFR during the Sediment Mass Loading Capacity (SMLC) testing. The SMLC study was a continuation of the removal efficiency study (an 33

37 additional 17 test runs). The SMLC test was terminated once the mass of the captured sediment exceeded 1.5X the recommended minimum amount for filter maintenance (one year). By the end of run #33, filter bypass had not yet occurred. The total mass of sediment captured was 434 lbs. and the overall removal efficiency was 89%. Scour Testing At this time the Kraken filter System is being submitted for approval for off-line testing; therefore no scour test data was provided. Sincerely, Richard S. Magee, Sc.D., P.E., BCEE 34

38 8. References 1. Good Harbour Laboratories Laboratory Performance Testing Quality Assurance Project Plan (QAPP) for Bio Clean s Kraken Membrane Filtration System. Prepared by Good Harbour Laboratories, June Good Harbour Laboratories, Notebook A010, pp , 53-66, 69, NJDEP 2013a. New Jersey Department of Environmental Protection Procedure for Obtaining Verification of a Stormwater Manufactured Treatment Device from New Jersey Corporation for Advanced Technology. January 25, NJDEP 2013b. New Jersey Department of Environmental Protection Laboratory Protocol to Assess Total Suspended Solids Removal by a Filtration Manufactured Treatment Device. January 25,

39 VERIFICATION APPENDIX 36

40 Introduction Manufacturer Bio Clean Environmental Services, Inc., 2972 San Luis Rey Road, Oceanside, CA Website: Phone: MTD - Kraken Filter verified models are shown in Table A-1. TSS Removal Rate 80% Off-line installation Detailed Specification NJDEP sizing tables and physical dimensions for Kraken Filter verified models are attached (Table A-1 and Table A-2). These Sizing Tables are valid for NJ following NJDEP Water Quality Design Storm Event of 1.25" in 2 hours (NJAC 7:8-5.5(a)). Maximum inflow drainage area o The maximum inflow drainage area is governed by the maximum treatment flow rate of each model size as presented in Table A-1 and Table A-4. Driving head will vary for a given Kraken Filter model based on the site specific configuration. For standard design, as tested under the NJDEP Protocol, 29.5 inches should be used as the driving head requirement. Bio Clean Environmental provides design support for each project. The drain down flow is regulated by a drain down orifice, sized so that a clean filter drains down in approximately 15 minutes. The drain down flow rate is expected to decrease as the filters ripen. See Kraken Filter O&M Manual for maintenance needs and procedures. This certification does not extend to the enhanced removal rates under NJAC 7:8-5.5 through the addition of settling chambers (such as hydrodynamic separators) or media filtration practices (such as a sand filter). 37

41 Table A-1 Kraken Filter Model MTFRs and Sediment Storage Capacity Model # of Cartridges MTFR (cfs) 1 50% Maximum Sediment Storage Volume (ft 3 ) KF KF KF KF KF KF KF KF KF KF NOTES: 1. Calculated based on 1.11x10-4 cfs/ft 2 of effective filtration treatment area. 38

42 Table A-2 Kraken Filter Model Standard Dimensions Model Sediment Chamber 1 Dimensions & Storage Capacity Length (ft) Width (ft) Area (Sq Ft) Storage Depth (ft) Storage Capacity (cu ft) Sediment Chamber 2 Dimensions & Storage Capacity Length (in) Width (in) Area (Sq Ft) Storage Depth (ft) Storage Capacity (cu ft) Width (ft) Length (ft) Area (Sq Ft) Filter Chambers Dimensions & Storage Capacity # of Chambers Total Area (Sq Ft) Storage Depth (ft) Storage Capacity (cu ft) # of Cartridges 2 Minus Cartridges Volume (cu ft) Storage Capacity (cu ft) TOTAL Total Sediment Storage Capacity (cu ft) Total Effective Sedimenation Area (sq ft) 1 Pre- Treatment Chamber Depth (ft) Wet Volumes 1 Filter Chambers Depth (ft) Wet Volume Pre- Treatment Chamber (cf) Wet Volume Filtration Chamber (cf) Total Wet Volume (cf) KF KF KF KF KF KF KF KF KF KF NOTES: 1. Depth of water in chambers during operation at MTFR. Depths above are based upon original estimates used in the QAPP of 2.92 ft for pre-treatment chamber & 2.67 ft for filter chambers. Maximum observed depths during NJ CAT testing were 2.60 ft for pre-treatment chamber & 2.46 ft for filter chambers at end the of run 33 indicating additional capacity was still available. The unit never got close to reaching the internal bypass weir. 2. The cartridges are feet in diameter. This is used to calculate the total volume of the cartridges and subtract it from the sediment storage volume in the filter chambers. This is a conservative calculation as the pleats in the cartridge allow for up to 50% of it's volume to store sediment on their influent side. For wet volume calculations the volume of the cartridges is not subtracted because water fills both the influent and effluent sides of the cartridges and actual volume of pleated material is negligible. Cartridge height is feet. 39

43 Table A-3 Kraken Filter Model Scaling Ratios Model # of Cartridges* Effective Filtration Treatment Area (sq. ft.) Total Effective Sedimentation Area (sq. ft.) Total Wet Volume (cu ft.) MTFR (cfs) Ratio of the MTFR to Effective Filtration Treatment Area Ratio of Effective Sedimentation Area to Effective Filtration Treatment Area Ratio of Wet Volume to Effective Filtration Treatment Area KF E E E-02 KF E E E-02 KF E E E-02 KF E E E-02 KF E E E-02 KF E E E-02 KF E E E-02 KF E E E-02 KF E E E-02 KF E E E-02 Notes: *Each tall cartridge has 170 sq. ft. of surface area and operates at an orifice controlled loading rate of 0.05 gpm/sq. ft. Other sizes and configurations available. All models sized based upon the maximum NJ CAT approved pre-treatment and filtration chamber area loading rate. 40

44 Table A-4 Kraken Filter Model Sizing and Loading 41

45 NJCAT TECHNOLOGY VERIFICATION ADDENDUM REPORT Kraken Membrane Filtration System Bio Clean Environmental Services, Inc. April,

46 Table of Contents Page Table of Contents List of Figures List of Tables Introduction Laboratory Testing Test Setup Test Sediment Scour Testing Additional Performance Claims Supporting Documentation Scour Testing Statements References

47 List of Figures Figure 1: Test Flow Loop Figure 2: Isokinetic Sampler.46 Figure 3: Fil-Trek Filter Housing Figure 4: Scour Test Background SSC List of Tables Page Table 1: Filter Element Retained Sediment Table 2: Chamber Sediment Pre-Load Amounts Table 3: Scour Test Sampling Frequency Table 4: Scour Test Flow Summary Table 5: Scour Test Background SSC Results Table 6: Scour Test Effluent SSC Results

48 1. Introduction In February 2016, NJCAT published a Technology Verification Report on the Kraken Membrane Filtration System (Kraken Filter System) manufactured by Bio Clean Environmental Services Inc. The Kraken Filter System is an engineered storm water quality treatment device utilizing a reusable membrane filter designed to remove high levels of TSS, hydrocarbons, and particulate bound metals and nutrients found in contaminated storm water. Each filter contains a large surface area which is designed to deal with high TSS concentrations. (See page 1 - Description of Technology for a more complete description of the technology.) The test program was conducted by Good Harbour Laboratories, an independent water technology testing lab, at their site in Mississauga, Ontario. Testing occurred during the month of August, Laboratory testing was done in accordance with the New Jersey Department of Environmental Protection Laboratory Protocol to Assess Total Suspended Solids Removal by a Filtration Manufactured Treatment Device (January, 2013). Limitations with the Good Harbour Laboratories testing capabilities at that time precluded conducting sediment scour testing. This addendum report provides the necessary sediment scour test results to support the use of the Kraken Filter System for on-line installations. 2. Laboratory Testing Scour testing occurred during the month of January, The same Kraken Filter System that was used for the Removal Efficiency Testing described in the February 2016 Verification Report was also used for the sediment scour test. 2.1 Test Setup The test flow loop (Figure 3 page 3) that was used for the removal efficiency testing had to be modified for the sediment scour test (Figure 1). These modifications were made due to flow capacity limitations of the laboratory. During performance and load testing the lab has sufficient water supply flow rates to run testing at 0.30 cfs without the need to recirculate the water. This allowed testing to be done with no filter for the effluent water. Since scour testing was done at a flow rate greater than the water supply s flow capacity a recirculating system needed to be used. Therefore the addition of a filter was used to remove background particulates. The test flow loop was modified as follows: Water was pumped from the inlet reservoir to the standpipe through a 6ʺ PVC line using an Armstrong Model 4380 centrifugal pump; Flow measurement was done using a MJK Magflux 7200 mag-type flow meter; Effluent samples were taken using an isokinetic sampler (Figure 2). The isokinetic sampler consisted of three, ½ʺ sampling tubes that were evenly spaced and vertically and centrally aligned; The system was configured as a closed loop, rather than a single pass; and A Fil-Trek model S4LPD F filter housing (Figure 3) with pleated bag filters (0.5 µm absolute) was used to remove background particulate. 45

49 Inlet Reservoir 6 Water Supply Line Recirculation Line Outlet Reservoir Effluent Sample Point Kraken Filter Auger Feeder Influent Sample Point Standpipe Receiving Tank Isokinetic Sampler To Waste Figure 1 Test Flow Loop Figure 2 Isokinetic Sampler 46

50 Figure 3 Fil-Trek Filter Housing Following removal efficiency testing, the Kraken Filter System sat undisturbed and allowed to dry out until the sediment scour testing was ready to begin. In preparation for the test, all of the filter elements were removed, being careful not to dislodge any of the captured sediment on the filters. The weight of the dry filter elements was recorded. All of the captured sediment inside the Kraken Filter System chambers was then removed and the system was hosed out. 2.2 Test Sediment The same batch of test sediment (Table 1 and Figure 8 page 7) used for the removal efficiency testing was also used for the sediment scour test. 2.3 Scour Testing Scour testing was conducted in accordance with Section 4 of the NJDEP Laboratory Protocol to Assess Total Suspended Solids Removal by a Filtration Manufactured Treatment Device (NJDEP, 2013). Testing was conducted at a target flow rate of 200% of the maximum treatment flow rate (MTFR). The used filters that were removed following removal efficiency testing were placed back into the Kraken Filter System in their original position. The mass of each used filter was compared to the average mass of a clean filter to determine the amount of sediment it held, the data is summarized in Table 1. 47

NJCAT TECHNOLOGY VERIFICATION. Debris Separating Baffle Box (DSBB ) Stormwater Treatment System. Bio Clean Environmental Services Inc.

NJCAT TECHNOLOGY VERIFICATION. Debris Separating Baffle Box (DSBB ) Stormwater Treatment System. Bio Clean Environmental Services Inc. NJCAT TECHNOLOGY VERIFICATION Debris Separating Baffle Box (DSBB ) Stormwater Treatment System Bio Clean Environmental Services Inc. February 2019 Contents List of Tables... ii List of Figures... iii 1.

More information

NJCAT Technology Verification (112 micron) Section E

NJCAT Technology Verification (112 micron) Section E NJCAT Technology Verification (112 micron) Section E NJCAT TECHNOLOGY VERIFICATION SciClone Hydrodynamic Separator Performance Verification of Sediment Capture and Light Liquid Retention Bio Clean Environmental

More information

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C. 1 2 3 4 5 6 New Jersey Department of Environmental Protection Laboratory Protocol to Assess Total Suspended Solids Removal by a Filtration Manufactured Treatment Device January 18, 2013 7 8 9 10 11 12

More information

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C.

1. Overview 2 2. Definitions 2 3. Laboratory Testing Criteria 2. A. Laboratory Qualifications 2. B. Analysis of TSS Samples 2. C. New Jersey Department of Environmental Protection Laboratory Protocol to Assess Total Suspended Solids Removal by a Hydrodynamic Sedimentation Manufactured Treatment Device January 25, 2013 Contents 1.

More information

NJCAT TECHNOLOGY VERIFICATION. BioPod Biofilter with StormMix Media. Oldcastle Precast Inc.

NJCAT TECHNOLOGY VERIFICATION. BioPod Biofilter with StormMix Media. Oldcastle Precast Inc. NJCAT TECHNOLOGY VERIFICATION BioPod Biofilter with StormMix Media Oldcastle Precast Inc. May 2018 Table of Contents Table of Contents... i List of Figures... ii List of Tables... iii 1. Description of

More information

NJCAT TECHNOLOGY VERIFICATION. Hydro International. August, 2015 (Revised Table A-2 January 2017)

NJCAT TECHNOLOGY VERIFICATION. Hydro International. August, 2015 (Revised Table A-2 January 2017) NJCAT TECHNOLOGY VERIFICATION Downstream Defender Stormwater Treatment Device Hydro International August, 2015 (Revised Table A-2 January 2017) TABLE OF CONTENTS List of Figures ii List of Tables iii 1.

More information

A Forterra Company Kraken Filter

A Forterra Company Kraken Filter A Forterra Company Kraken Filter A Stormwater Filtration Solution OVERVIEW The Bio Clean Kraken Filter is a state-of-the-art system utilizing advanced membrane filtration, ensuring a high level of removal

More information

NJCAT TECHNOLOGY VERIFICATION. Oldcastle PerkFilter System with ZPC Media. Oldcastle Precast Stormwater

NJCAT TECHNOLOGY VERIFICATION. Oldcastle PerkFilter System with ZPC Media. Oldcastle Precast Stormwater NJCAT TECHNOLOGY VERIFICATION Oldcastle PerkFilter System with ZPC Media Oldcastle Precast Stormwater May 2017 Table of Contents Page Table of Contents... i List of Figures... ii List of Tables... ii 1.

More information

NJCAT TECHNOLOGY VERIFICATION. BaySaver Barracuda Hydrodynamic Separator. BaySaver Technologies, LLC

NJCAT TECHNOLOGY VERIFICATION. BaySaver Barracuda Hydrodynamic Separator. BaySaver Technologies, LLC NJCAT TECHNOLOGY VERIFICATION BaySaver Barracuda Hydrodynamic Separator BaySaver Technologies, LLC September 2017 TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description of Technology 1

More information

NJCAT TECHNOLOGY VERIFICATION. First Defense HC Stormwater Treatment Device. Hydro International

NJCAT TECHNOLOGY VERIFICATION. First Defense HC Stormwater Treatment Device. Hydro International NJCAT TECHNOLOGY VERIFICATION First Defense HC Stormwater Treatment Device Hydro International February, 2016 TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description of Technology 1 2. Laboratory

More information

NJCAT TECHNOLOGY VERIFICATION

NJCAT TECHNOLOGY VERIFICATION NJCAT TECHNOLOGY VERIFICATION Continuous Deflective Separator (CDS ) Stormwater Treatment Device (For Models that meet New Jersey s Unique Sizing Requirements) Contech Engineered Solutions LLC September,

More information

NJCAT TECHNOLOGY VERIFICATION. StormKleener Filter Cartridge System. Lane Enterprises Inc.

NJCAT TECHNOLOGY VERIFICATION. StormKleener Filter Cartridge System. Lane Enterprises Inc. NJCAT TECHNOLOGY VERIFICATION StormKleener Filter Cartridge System Lane Enterprises Inc. May 2018 TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description of Technology 1 2. Laboratory Testing

More information

APPENDIX C NJDEP CERTIFICATION LETTER & NJCAT VERIFICATION REPORT

APPENDIX C NJDEP CERTIFICATION LETTER & NJCAT VERIFICATION REPORT APPENDIX C NJDEP CERTIFICATION LETTER & NJCAT VERIFICATION REPORT This page intentionally left blank for printing PHILIP D. MURPHY DEPARTMENT OF ENVIRONMENTAL PROTECTION CATHERINE R. MCCABE Governor Mail

More information

NJCAT TECHNOLOGY VERIFICATION. Up-Flo Filter. Hydro International

NJCAT TECHNOLOGY VERIFICATION. Up-Flo Filter. Hydro International NJCAT TECHNOLOGY VERIFICATION Up-Flo Filter (450R Filter Ribbon Media) Hydro International June 2018 i TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description of Technology 1 2. Laboratory

More information

OPERATION & MAINTENANCE

OPERATION & MAINTENANCE Grate Inlet Filter OPERATION & MAINTENANCE Bio Clean Environmental Services, Inc. 398 Via El Centro Oceanside, CA 92058 www.biocleanenvironmental.com p: 760.433.7640 f: 760.433.3176 OPERATION & MAINTENANCE

More information

NJCAT TECHNOLOGY VERIFICATION. HydroStorm Hydrodynamic Separator. Hydroworks, LLC

NJCAT TECHNOLOGY VERIFICATION. HydroStorm Hydrodynamic Separator. Hydroworks, LLC NJCAT TECHNOLOGY VERIFICATION HydroStorm Hydrodynamic Separator Hydroworks, LLC February 2018 TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description of Technology 1 2. Laboratory Testing

More information

NJCAT TECHNOLOGY VERIFICATION. Aqua-Filter TM Stormwater Filtration System with Perlite Media. AquaShield TM, Inc.

NJCAT TECHNOLOGY VERIFICATION. Aqua-Filter TM Stormwater Filtration System with Perlite Media. AquaShield TM, Inc. NJCAT TECHNOLOGY VERIFICATION Aqua-Filter TM Stormwater Filtration System with Perlite Media AquaShield TM, Inc. June 2018 TABLE OF CONTENTS Page List of Figures List of Tables iii iv 1. Description of

More information

NJCAT TECHNOLOGY VERIFICATION. Aqua-Filter TM Stormwater Filtration System Model AF-3.48 Round with Perlite Media. AquaShield TM, Inc.

NJCAT TECHNOLOGY VERIFICATION. Aqua-Filter TM Stormwater Filtration System Model AF-3.48 Round with Perlite Media. AquaShield TM, Inc. NJCAT TECHNOLOGY VERIFICATION Aqua-Filter TM Stormwater Filtration System Model AF-3.48 Round with Perlite Media AquaShield TM, Inc. March 2017 Revised June 2018 (Verification specific to Aqua-Filter TM

More information

NJCAT TECHNOLOGY VERIFICATION. Cascade Separator Contech Engineered Solutions

NJCAT TECHNOLOGY VERIFICATION. Cascade Separator Contech Engineered Solutions NJCAT TECHNOLOGY VERIFICATION Cascade Separator Contech Engineered Solutions November 2018 TABLE OF CONTENTS 1. Description of Technology... 1 2. Laboratory Testing... 3 2.1. Test Unit... 3 2.2. Test Setup...

More information

A. Manufactured Treatment Device Characteristics

A. Manufactured Treatment Device Characteristics Requirements for Interim Certification of Hydrodynamic Sedimentation Devices for Total Suspended Solids Based on Laboratory Testing DRAFT April 28, 2009 The New Jersey Stormwater Management Rules at N.J.A.C.

More information

NJCAT TECHNOLOGY VERIFICATION. Aqua-Filter TM Stormwater Filtration System with Perlite Media. AquaShield TM, Inc.

NJCAT TECHNOLOGY VERIFICATION. Aqua-Filter TM Stormwater Filtration System with Perlite Media. AquaShield TM, Inc. NJCAT TECHNOLOGY VERIFICATION Aqua-Filter TM Stormwater Filtration System with Perlite Media AquaShield TM, Inc. May 2018 TABLE OF CONTENTS Page List of Figures List of Tables iii iv 1. Description of

More information

A signed statement from the manufacturer listing the protocol requirements and indicating that all of the requirements were met or exceeded.

A signed statement from the manufacturer listing the protocol requirements and indicating that all of the requirements were met or exceeded. Protocol for Manufactured Hydrodynamic Sedimentation Devices for Total Suspended Solids Based on Laboratory Analysis Dated August 5, 2009, Revised December 15, 2009 The New Jersey Stormwater Management

More information

Capability of the Aqua-Swirl Concentrator to Remove Trash from Stormwater Runoff

Capability of the Aqua-Swirl Concentrator to Remove Trash from Stormwater Runoff Capability of the Aqua-Swirl Concentrator to Remove Trash from Stormwater Runoff June 27, 2012 The purpose of this document is to demonstrate the capability of the Aqua-Swirl Concentrator to capture trash

More information

EXHIBIT 2:Optional Online Installation Re-entrainment/scour testing of the Terre Kleen18 Hydrodynamic Separator Stormwater Treatment unit per NJDEP

EXHIBIT 2:Optional Online Installation Re-entrainment/scour testing of the Terre Kleen18 Hydrodynamic Separator Stormwater Treatment unit per NJDEP EXHIBIT 2:Optional Online Installation Re-entrainment/scour testing of the Terre Kleen18 Hydrodynamic Separator Stormwater Treatment unit per NJDEP Testing Protocol dated: August 25, 2009, as amended December

More information

Design Manual. StormKleener Filter Cartridge System for Storm Water Management

Design Manual. StormKleener Filter Cartridge System for Storm Water Management Design Manual StormKleener Filter Cartridge System for Storm Water Management Table of Contents 1.0 StormKleener Product Information... 1 2.0 Individual Cartridge Design and Operation... 2 2.1 Charging

More information

NJCAT TECHNOLOGY VERIFICATION. Jensen Deflective Separator (JDS) Jensen Stormwater Systems

NJCAT TECHNOLOGY VERIFICATION. Jensen Deflective Separator (JDS) Jensen Stormwater Systems NJCAT TECHNOLOGY VERIFICATION Jensen Deflective Separator (JDS) Jensen Stormwater Systems February 2019 TABLE OF CONTENTS Page List of Figures List of Tables iii iv 1. Description of Technology 1 2. Laboratory

More information

Conditional Interim Certification Findings

Conditional Interim Certification Findings NJDEP Technology Certification Program: Conditional Interim Certification Findings Bureau of Sustainable Communities & Innovative Technologies Division of Science, Research & Technology 401 E State Street,

More information

NJCAT TECHNOLOGY VERIFICATION. Fresh Creek Technologies Inc. February, 2016 (Revised Table A-1 January 2017)

NJCAT TECHNOLOGY VERIFICATION. Fresh Creek Technologies Inc. February, 2016 (Revised Table A-1 January 2017) NJCAT TECHNOLOGY VERIFICATION SiteSaver Stormwater Treatment Device Fresh Creek Technologies Inc. February, 2016 (Revised Table A-1 January 2017) Table of Contents List of Figures... iii List of Tables...v

More information

Attachment 1. Manufactured Treatment Device (MTD) Registration

Attachment 1. Manufactured Treatment Device (MTD) Registration Attachment 1 Manufactured Treatment Device (MTD) Registration 1. Manufactured Treatment Device Name: BaySaver Barracuda 2. Company Name: BaySaver Technologies Mailing Address: 1030 Deer Hollow Drive City:

More information

NJCAT TECHNOLOGY VERIFICATION. Filterra Bioretention System. Contech Engineered Solutions

NJCAT TECHNOLOGY VERIFICATION. Filterra Bioretention System. Contech Engineered Solutions NJCAT TECHNOLOGY VERIFICATION Filterra Bioretention System Contech Engineered Solutions May, 2014 TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description of Technology 1 2. Laboratory Testing

More information

June 30, Jay Holtz, P.E. Director of Engineering Oldcastle Precast, Inc SW Macadam Ave., #376 Portland, OR 97239

June 30, Jay Holtz, P.E. Director of Engineering Oldcastle Precast, Inc SW Macadam Ave., #376 Portland, OR 97239 CHRIS CHRISTIE Governor KIM GUADAGNO Lt. Governor DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Nonpoint Pollution Control Division of Water Quality Mail Code 401-02B Post Office Box 420 Trenton, New

More information

NJCAT TECHNOLOGY VERIFICATION. Filterra Bioretention System. Americast Inc.

NJCAT TECHNOLOGY VERIFICATION. Filterra Bioretention System. Americast Inc. NJCAT TECHNOLOGY VERIFICATION Filterra Bioretention System Americast Inc. August, 2013 TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description of Technology 1 2. Laboratory Testing 2 2.1

More information

STORMWATER MANAGEMENT

STORMWATER MANAGEMENT DRAINAGE SOLUTIONS SINCE 1908 STORMWATER MANAGEMENT STORMWATER TREATMENT AND FLOW CONTROL ENVIRONMENTAL PROTECTION EASE OF MAINTENANCE RELIABLE PERFORMANCE ARMTEC.COM STORMWATER TREATMENT Armtec is excited

More information

VERIFICATION STATEMENT

VERIFICATION STATEMENT Verification Statement Verification Statement Verification Statement VERIFICATION STATEMENT GLOBE Performance Solutions Verifies the performance of Stormceptor EF4 and EFO4 Oil-Grit Separators Developed

More information

Revised MTD Lab Certification Dual Vortex Separator (DVS) Stormwater Treatment Device by Oldcastle Stormwater Solutions On-line Installation

Revised MTD Lab Certification Dual Vortex Separator (DVS) Stormwater Treatment Device by Oldcastle Stormwater Solutions On-line Installation CHRIS CHRISTIE Governor KIM GUADAGNO Lt. Governor DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Nonpoint Pollution Control Division of Water Quality 401-02B Post Office Box 420 Trenton, New Jersey 08625-0420

More information

Stormwater Manufactured Treatment Devices (MTDs)

Stormwater Manufactured Treatment Devices (MTDs) Supplemental Technical Specification for Stormwater Manufactured Treatment Devices (MTDs) SCDOT Designation: SC-M-815-13 (08/13) 1.0 Stormwater Manufactured Treatment Devices Stormwater Manufactured Treatment

More information

Attachment 1. Manufactured Treatment Device (MTD) Registration

Attachment 1. Manufactured Treatment Device (MTD) Registration Attachment 1 Manufactured Treatment Device (MTD) Registration 1. Manufactured Treatment Device Name: BioPod Biofilter System with StormMix Media 2. Company Name: Oldcastle Precast, Inc., DBA Oldcastle

More information

PERKFILTER. Design Guide

PERKFILTER. Design Guide PERKFILTER Design Guide TABLE OF CONTENTS Description Function Treatment Processes System Hydraulics System Sizing PerkFilter Configurations Inspection and Maintenance Requirements Verification and Approvals

More information

VERIFICATION STATEMENT

VERIFICATION STATEMENT Verification Statement Verification Statement Verification Statement VERIFICATION STATEMENT Verifies the performance of Jellyfish Filter JF4-2-1 Developed by Imbrium Systems, Inc., Whitby, Ontario, Canada

More information

TOTAL SUSPENDED SOLIDS REMOVAL TEST OF A HIGH DENSITY POLYETHYLENE WATER QUALITY UNIT. By James T. Mailloux Dean K. White

TOTAL SUSPENDED SOLIDS REMOVAL TEST OF A HIGH DENSITY POLYETHYLENE WATER QUALITY UNIT. By James T. Mailloux Dean K. White TOTAL SUSPENDED SOLIDS REMOVAL TEST OF A HIGH DENSITY POLYETHYLENE WATER QUALITY UNIT By James T. Mailloux Dean K. White Submitted to ADVANCED DRAINAGE SYSTEMS 250-04/H1098F September 2004 TOTAL SUSPENDED

More information

Protocol for Total Suspended Solids Removal Based on Field Testing Amendments to TARP Protocol August 5, 2009

Protocol for Total Suspended Solids Removal Based on Field Testing Amendments to TARP Protocol August 5, 2009 Protocol for Total Suspended Solids Removal Based on Field Testing Amendments to TARP Protocol August 5, 2009 The New Jersey Stormwater Management Rules at N.J.A.C. 7:8-5.5 require major development projects

More information

NJCAT TECHNOLOGY VERIFICATION. Nutrient Separating Baffle Box with Hydro-Variant Technology. Suntree Technologies Inc.

NJCAT TECHNOLOGY VERIFICATION. Nutrient Separating Baffle Box with Hydro-Variant Technology. Suntree Technologies Inc. NJCAT TECHNOLOGY VERIFICATION Nutrient Separating Baffle Box with Hydro-Variant Technology Suntree Technologies Inc. October, 2016 TABLE OF CONTENTS List of Figures ii List of Tables iii 1. Description

More information

Lt. Governor Trenton, NJ Phone: (609) / Fax: (609)

Lt. Governor Trenton, NJ Phone: (609) / Fax: (609) PHILIP D. MURPHY DEPARTMENT OF ENVIRONMENTAL PROTECTION CATHERINE R. MCCABE Governor Mail Code 401-02B Commissioner Division of Water Quality Bureau of Nonpoint Pollution Control SHEILA Y. OLIVER P.O.

More information

VERIFICATION TESTING OF THE HYDROGUARD HG6 HYDRODYNAMIC SEPARATOR STORMWATER TREATMENT UNIT FINAL REPORT. By James T. Mailloux Amie N.

VERIFICATION TESTING OF THE HYDROGUARD HG6 HYDRODYNAMIC SEPARATOR STORMWATER TREATMENT UNIT FINAL REPORT. By James T. Mailloux Amie N. VERIFICATION TESTING OF THE HYDROGUARD HG6 HYDRODYNAMIC SEPARATOR STORMWATER TREATMENT UNIT FINAL REPORT By James T. Mailloux Amie N. Humphrey Submitted to HYDROWORKS, LLC 2008-332-H1323 December 23, 2008

More information

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED Specifies requirements for construction and performance of an underground stormwater quality

More information

Features: The Most Advanced Name in water management solutions TM

Features: The Most Advanced Name in water management solutions TM S4 The Barracuda S4 is a market-changing stormwater quality technology. This high performance vortex hydrodynamic separator is designed to remove total suspended solids in order to protect our precious

More information

Manufactured Water Quality Solutions

Manufactured Water Quality Solutions Manufactured Water Quality Solutions Problem. Solution. Parking Lot Project Scenario #1 Parking Lot Expansion with a net increase of impervious area Scenario #2 Parking Lot Redevelopment with no increase

More information

Addendum to the Hydro International s Downstream Defender Conditional Interim Certification

Addendum to the Hydro International s Downstream Defender Conditional Interim Certification October 11, 2007 Addendum to the Hydro International s Downstream Defender Conditional Interim Certification Notification of the completion of the field testing phase for the Hydro International s Downstream

More information

Table 1: Water Quality Event (WQE) Design Intensities. i 1 (t c 5 min) (in/hr) a b. tc c

Table 1: Water Quality Event (WQE) Design Intensities. i 1 (t c 5 min) (in/hr) a b. tc c Supplemental Technical Specification for Stormwater Manufactured Treatment Devices (MTDs) SCDOT Designation: SC-M-815-13 (8/11) 1.0 Stormwater Manufactured Treatment Devices Stormwater Manufactured Treatment

More information

Features: The Most Advanced Name in water management solutions TM

Features: The Most Advanced Name in water management solutions TM S4 The Barracuda S4 is a market-changing stormwater quality technology. This high performance vortex hydrodynamic separator is designed to remove total suspended solids in order to protect our precious

More information

SECTION DOWNSTREAM DEFENDER

SECTION DOWNSTREAM DEFENDER SECTION 02631 DOWNSTREAM DEFENDER PART 1 - GENERAL 1.01 SCOPE A. Work described in this section includes furnishing all labor, equipment, materials, tools and incidentals required for a complete and operable

More information

ENGINEERED SOLUTIONS. CDS Guide Operation, Design, Performance and Maintenance

ENGINEERED SOLUTIONS. CDS Guide Operation, Design, Performance and Maintenance ENGINEERED SOLUTIONS CDS Guide Operation, Design, Performance and Maintenance CDS Design Basics Using patented continuous deflective separation technology, the CDS system screens, separates and traps debris,

More information

Sorbtive Vault Operations & Maintenance Manual

Sorbtive Vault Operations & Maintenance Manual Media Sorbtive Vault Operations & Maintenance Manual Overview These instructions provide a description of the operation, inspection and maintenance aspects of Sorbtive Vault. Safety Notice Jobsite safety

More information

Jensen Deflective Separator (JDS) Stormwater Treatment Unit

Jensen Deflective Separator (JDS) Stormwater Treatment Unit Jensen Deflective Separator (JDS) Stormwater Treatment Unit A Full Capture, Screening, Swirl-Concentrating, Stormwater Treatment Unit The Jensen Deflective Separator (JDS) is a fullcapture, screening,

More information

Aqua-Swirl Stormwater Treatment System

Aqua-Swirl Stormwater Treatment System Aqua-Swirl Stormwater Treatment System Inspection and Maintenance Manual AquaShield TM, Inc. 2705 Kanasita Drive Chattanooga, TN 37343 Toll free (888) 344-9044 Phone: (423) 870-8888 Fax: (423) 826-2112

More information

Aqua-Swirl Stormwater Treatment System

Aqua-Swirl Stormwater Treatment System Aqua-Swirl Stormwater Treatment System Inspection and Maintenance Manual AquaShield TM, Inc. 2733 Kanasita Drive Suite 111 Chattanooga, TN 37343 Toll free (888) 344-9044 Phone: (423) 870-8888 Fax: (423)

More information

FULL SCALE LABORATORY EVALUATION OF STORMCEPTOR MODEL STC 450 FOR REMOVAL OF TSS

FULL SCALE LABORATORY EVALUATION OF STORMCEPTOR MODEL STC 450 FOR REMOVAL OF TSS FULL SCALE LABORATORY EVALUATION OF STORMCEPTOR MODEL STC 450 FOR REMOVAL OF TSS Brian Lee, Scott Perry AUTHORS: Stormwater Specialists, Imbrium Systems Corporation, 12 Madison Ave, Toronto, Ontario, M5R

More information

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND JULY 2002 Copyright 2001 H.I.L. Technology, Inc. All rights reserved. This report was

More information

4.28 Underground Detention

4.28 Underground Detention 4.28 Underground Detention Detention Structural Stormwater Control Description: Detention storage located in underground tanks or vaults designed to provide water quantity control through detention and/or

More information

March 21, Derek M. Berg Contech Engineered Solutions, LLC 71 US Route 1, Suite F Scarborough, ME 04074

March 21, Derek M. Berg Contech Engineered Solutions, LLC 71 US Route 1, Suite F Scarborough, ME 04074 CHRIS CHRISTIE Governor KIM GUADAGNO Lt. Governor DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Nonpoint Pollution Control Division of Water Quality 401-02B Post Office Box 420 Trenton, New Jersey 08625-0420

More information

March 15, Mark B. Miller, Research Scientist AquaShield TM, Inc Kanasita Drive, Suite 111 Chattanooga, Tennessee 37343

March 15, Mark B. Miller, Research Scientist AquaShield TM, Inc Kanasita Drive, Suite 111 Chattanooga, Tennessee 37343 KIM GUADAGNO CHRIS CHRISTIE Governor Lt. Governor DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Nonpoint Pollution Control Division of Water Quality 401-02B Post Office Box 420 Trenton, New Jersey 08625-0420

More information

BIOPOD TM BIOFILTER. with StormMix Biofiltration Media. Inspection and Maintenance Guide

BIOPOD TM BIOFILTER. with StormMix Biofiltration Media. Inspection and Maintenance Guide BIOPOD TM BIOFILTER with StormMix Biofiltration Media Inspection and Maintenance Guide BioPod Biofilter with StormMix Biofiltration Media Description The BioPod Biofilter System (BioPod) is a stormwater

More information

BIOPOD TM BIOFILTER WITH STORMMIX BIOFILTRATION MEDIA. Inspection and Maintenance Guide

BIOPOD TM BIOFILTER WITH STORMMIX BIOFILTRATION MEDIA. Inspection and Maintenance Guide BIOPOD TM BIOFILTER WITH STORMMIX TM BIOFILTRATION MEDIA Inspection and Maintenance Guide BioPod Biofilter with StormMix Biofiltration Media Description The BioPod Biofilter System (BioPod) is a stormwater

More information

SUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM. By James T. Mailloux

SUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM. By James T. Mailloux SUSPENDED SOLIDS REMOVAL TEST OF A 22 X 44 INCH STORMBASIN MODULAR STORMWATER FILTRATION SYSTEM By James T. Mailloux Submitted to FABCO INDUSTRIES, INC. June 2005 ALDEN RESEARCH LABORATORY, INC. 30 Shrewsbury

More information

STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE

STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED This section specifies requirements for constructing underground stormwater treatment

More information

Hydrodynamic Separation Product Calculator

Hydrodynamic Separation Product Calculator Hydrodynamic Separation Product Calculator Example Project BMP #1 CDS 2015-4 Project Information Project Name Example Project Option # A Country US State Kentucky City Covington Contact Information First

More information

NJCAT TECHNOLOGY VERIFICATION. StormKeeper Chamber Sediment Strip. Lane Enterprises Inc.

NJCAT TECHNOLOGY VERIFICATION. StormKeeper Chamber Sediment Strip. Lane Enterprises Inc. NJCAT TECHNOLOGY VERIFICATION StormKeeper Chamber Sediment Strip Lane Enterprises Inc. May 2017 Table of Contents List of Figures... iii List of Tables... iv 1. Introduction...1 1.1 New Jersey Corporation

More information

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description

WQ-06 SAND FILTER. 1.0 Sand Filter. Greenville County Technical Specification for: 1.1 Description Greenville County Technical Specification for: WQ-06 SAND FILTER 1.0 Sand Filter 1.1 Description Sand Filters remove pollutants through sedimentation and filtration within the sand. The primary components

More information

CUDO CUBES. Operations and Maintenance Manual (Underground Retention / Detention / Infiltration / Water Reuse Systems)

CUDO CUBES. Operations and Maintenance Manual (Underground Retention / Detention / Infiltration / Water Reuse Systems) CUDO CUBES Operations and Maintenance Manual (Underground Retention / Detention / Infiltration / Water Reuse Systems) CUDO Stormwater Cube - Modular Stormwater Systems Description / Basic Function CUDO

More information

Stormwater Technology Testing Center (STTC) Presented by: Paul R. Wirfs, PE and Dan Gunther, PE April 2016

Stormwater Technology Testing Center (STTC) Presented by: Paul R. Wirfs, PE and Dan Gunther, PE April 2016 Stormwater Technology Testing Center (STTC) Presented by: Paul R. Wirfs, PE and Dan Gunther, PE April 2016 Stormwater There is a lot going on.... Stormwater Treatment - Engineering in many forms.. Stormwater

More information

STORMWATER TREATMENT FIELD DEMONSTRATION AND EVALUATION

STORMWATER TREATMENT FIELD DEMONSTRATION AND EVALUATION STORMWATER TREATMENT FIELD DEMONSTRATION AND EVALUATION Frank Sagona 1, Doyle Dobson 2, Mark Miller 3 AUTHORS: 1 Watershed Director, Conasauga River Alliance, 125 Redbud Road NE Suite 7, 2 Doyle Dobson,

More information

Stormwater Technology Testing Center (STTC)

Stormwater Technology Testing Center (STTC) (STTC) Paul R. Wirfs, PE Oregon DOT John Lenth Herrera, Inc 1 Stormwater What and Why Stormwater There is a lot going on.... 2 Stormwater Treatment - Engineering in many forms.. Stormwater Treatment Technologies

More information

DRAFT PTP-06. Activity: Water Quality Units

DRAFT PTP-06. Activity: Water Quality Units Shelbyville, Kentucky Stormwater Best Management Practices (BMPs) Stormwater Pollution Treatment Practices (Structural) Activity: Water Quality Units PLANNING CONSIDERATIONS: Design Life: 35 years WQ Acreage

More information

4.4.6 Underground Detention

4.4.6 Underground Detention 4.4.6 Underground Detention Limited Application Water Quality BMP Description: Detention storage located in underground pipe systems or vaults designed to provide water quantity control through detention

More information

MTD Lab Certification First Defense HC (FDHC) Stormwater Treatment Device by Hydro International On-line Installation

MTD Lab Certification First Defense HC (FDHC) Stormwater Treatment Device by Hydro International On-line Installation CHRIS CHRISTIE Governor KIM GUADAGNO Lt. Governor DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Nonpoint Pollution Control Division of Water Quality 401-02B Post Office Box 420 Trenton, New Jersey 08625-0420

More information

MTD Laboratory Certification Stormwater Management StormFilter (StormFilter) by Contech Engineered Solutions LLC Off-line Installation

MTD Laboratory Certification Stormwater Management StormFilter (StormFilter) by Contech Engineered Solutions LLC Off-line Installation CHRIS CHRISTIE Governor KIM GUADAGNO Lt. Governor DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Nonpoint Pollution Control Division of Water Quality Mail Code 401-02B Post Office Box 420 Trenton, New

More information

THE STORMKLEENER TM ABOUT LANE WATER QUALITY DEVICES

THE STORMKLEENER TM ABOUT LANE WATER QUALITY DEVICES WATER QUALITY DEVICES THE STORMKLEENER TM The Lane StormKleener Filter Cartridge System is a storm water treatment device consisting of one or multiple cylindrical media filled cartridges housed in a containment

More information

History 11/16/2015. Stormwater Technology Testing Center. Stormwater Technology Testing Center. Stormwater Technology Testing Center

History 11/16/2015. Stormwater Technology Testing Center. Stormwater Technology Testing Center. Stormwater Technology Testing Center Stormwater Technology Testing Center (STTC) Presented by: Paul R. Wirfs, PE November 2015 Mission The STTC s mission is to verify the operation and maintenance performance and life-cycle costs of stormwater

More information

Operation & Maintenance (OM) Manual v01. Bioretention Systems ENGINEERED SOLUTIONS

Operation & Maintenance (OM) Manual v01. Bioretention Systems ENGINEERED SOLUTIONS Operation & Maintenance (OM) Manual v01 Bioretention Systems ENGINEERED SOLUTIONS Bioretention Systems Table of Contents Overview Filterra General Description Filterra Schematic Basic Operations Design

More information

Aqua-Swirl Stormwater Treatment System

Aqua-Swirl Stormwater Treatment System Aqua-Swirl Stormwater Treatment System Inspection and Maintenance Manual AquaShield, Inc. 2705 Kanasita Drive, Chattanooga, TN 37343 Phone: (423) 870-8888 Fax: (423) 826-2112 Email: info@aquashieldinc.com

More information

C l e a r S o l u t i o n s

C l e a r S o l u t i o n s C l e a r S o l u t i o n s CrystalStream Technologies has built a reputation for engineering excellence, integrity of design and dedication to the spirit of stormwater pollutant mitigation. Our drive

More information

Inspection And Maintenance Guide

Inspection And Maintenance Guide Storm water Filtration Chamber Inspection And Maintenance Guide Important: Inspection and maintenance to be performed by qualified personnel only. Helical filter replacement may require personnel properly

More information

A Forterra Company UrbanPond

A Forterra Company UrbanPond A Forterra Company UrbanPond A Stormwater Storage Solution OVERVIEW The Bio Clean UrbanPond TM is a technological breakthrough in underground stormwater management. Its unique square tessellation assembly

More information

ENGINEERED SOLUTIONS

ENGINEERED SOLUTIONS ENGINEERED SOLUTIONS CDS Solutions Guide Scan Me! Continuous Deflective Separation - CDS Superior Stormwater Trash and Sediment Removal The CDS is a swirl concentrator hybrid technology that uses continuous

More information

EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS

EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS EFFECTIVE AND EASILY MAINTAINED TREATMENT SOLUTIONS When it rains, surface runoff carries pollutants, suspended solids and hydrocarbons. Floating debris is swept through collection systems in subsurface

More information

System Maintenance Table of Contents

System Maintenance Table of Contents Table of Contents AQUASHIELD PRODUCTS 2 System Maintenance 2 Inspection 3 Aqua-Swirl Maintenance 3 Aqua-Swirl Inspection Procedure 3 Aqua-Swirl Cleanout Procedure 4 Aqua-Swirl Inspection Data Sheet 5 Aqua-Swirl

More information

Operation & Maintenance (OM) Manual v01. Bioretention Systems

Operation & Maintenance (OM) Manual v01. Bioretention Systems Operation & Maintenance (OM) Manual v01 Bioretention Systems Bioretention Systems Table of Contents Overview Filterra General Description Filterra Schematic Basic Operations Design Maintenance Maintenance

More information

STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE

STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE STANDARD SPECIFICATION FOR OIL GRIT SEPARATOR (OGS) STORMWATER QUALITY TREAMENT DEVICE PART 1 GENERAL 1.1 WORK INCLUDED This section specifies requirements for constructing underground stormwater treatment

More information

BAYFILTER SPECIFICATIONS

BAYFILTER SPECIFICATIONS PART 1.00 GENERAL 1.1 DESCRIPTION BAYFILTER SPECIFICATIONS A. The BayFilter system s internal components manufacturer selected by the Contractor and approved by the Engineer, shall furnish all labor, materials,

More information

Advanced Stormwater Biofiltration. MWS Linear

Advanced Stormwater Biofiltration. MWS Linear Advanced Stormwater Biofiltration MWS Linear Contents 1 Introduction 2 Applications 3 Configurations 4 Advantages 5 Operation 6 Orientations Bypass 7 Performance Approvals 8 Sizing 9 Installation Maintenance

More information

High-Rate Stormwater Treatment with Up-Flow Filtration

High-Rate Stormwater Treatment with Up-Flow Filtration 1 High-Rate Stormwater Treatment with Up-Flow Filtration Noboru Togawa and Robert Pitt The objective of this research is to examine the removal capacities of a highrate stormwater filtration device, in

More information

Nutrient Removing Filtration System Operation and Maintenance Manual

Nutrient Removing Filtration System Operation and Maintenance Manual Nutrient Removing Filtration System Operation and Maintenance Manual Version 1.0 Suntree Technologies, Inc 798 Clearlake Road, Suite 2 Cocoa Florida 32922 321.637.7552 www.suntreetech.com info@suntreetech.com

More information

Conditional Interim Certification Findings

Conditional Interim Certification Findings JON S. CORZINE Governor tau of Ne-Ut lie-rs!"y DEPARTMENT OF ENVIRONMENTAL PROTECTION Office of the Commissioner 401 E. State Street - ih Floor PO Box 402 Trenton, NJ 08625 Tel: 609-633-1123 Fax: 609-984-3962

More information

STORMFILTER THE MOST PROVEN. stormwater filtration system

STORMFILTER THE MOST PROVEN. stormwater filtration system STORMFILTER THE MOST PROVEN stormwater filtration system SOLVES THE MOST STRINGENT PROBLEMATICS in stormwater treatment The evolution and implementation of a more stricter regulatory framework is gradually

More information

Field Evaluation of a Stormceptor Model STC 1200 Westwood, Massachusetts. Prepared by: Stormceptor Group of Companies

Field Evaluation of a Stormceptor Model STC 1200 Westwood, Massachusetts. Prepared by: Stormceptor Group of Companies F I E L D M O N I T O R I N G Field Evaluation of a Stormceptor Model STC 1200 Westwood, Massachusetts Prepared by: Stormceptor Group of Companies June, 2004 Field Monitoring Evaluation of a Westwood,

More information

CHALLENGING URBAN BMP ASSUMMPTIONS. John Moll, CEO

CHALLENGING URBAN BMP ASSUMMPTIONS. John Moll, CEO CHALLENGING URBAN BMP ASSUMMPTIONS John Moll, CEO Chief Executive Officer, CrystalStream Technologies, 2080 Sugarloaf Parkway, Suite 230, Lawrenceville, GA, 30245, USA; johnmoll@crystalstream.com ABSTRACT

More information

Comprehensive Stormwater Solutions

Comprehensive Stormwater Solutions Modular Wetlands System Linear Biofiltration Comprehensive Stormwater Solutions A Forterra Company OVERVIEW The Bio Clean Modular Wetlands System Linear (MWS Linear) represents a pioneering breakthrough

More information

ENGINEERED SOLUTIONS. StormFilter Inspection and Maintenance Procedures

ENGINEERED SOLUTIONS. StormFilter Inspection and Maintenance Procedures ENGINEERED SOLUTIONS StormFilter Inspection and Maintenance Procedures Maintenance Guidelines The primary purpose of the Stormwater Management StormFilter is to filter out and prevent pollutants from entering

More information

ENGINEERED SOLUTIONS

ENGINEERED SOLUTIONS ENGINEERED SOLUTIONS Hydrodynamic Separation Solutions Guide Scan Me! Hydrodynamic Separation Selecting the Right Stormwater Solution Just Got Easier... It s simple to choose the right stormwater solution

More information