The best practice of climate needs for pigs and how to fulfil it VIV Master Class Vietnam
|
|
- Hugo Campbell
- 5 years ago
- Views:
Transcription
1 The best practice of climate needs for pigs and how to fulfil it VIV Master Class Vietnam Mr Carsten Bo Pedersen & Mr Jørgen Møller Andersen, Climate Expert from SKOV Asia
2 The best practice of climate needs for pigs and how to fulfil it Carsten Bo Pedersen & Jørgen Møller Andersen, Climate Expert from SKOV Asia
3 SKOV VNU Vietnam
4 The best practice of climate needs for pigs and how to fullfill it. By Carsten Bo Pedersen and Joergen Moeller Andersen Area sales managers Skov Asia Bangkok.
5 When we close the houses we take responsibility
6 Different behave for different age and size There are a lot of different ways to grow pigs. There is also a lot of different systems to keep the pigs in there houses.
7 Why ventilate? To control the climate High daily gain Low feed conversion rate (FCR) High state of health Low mortality Ensure right behaviour in the pen Ensure good air quality CO 2, NH 3, H 2 S, dust etc. Minimum ventilation m 3 /h
8 Why ventilate Temperature o C CO 2 Humidity Heat NH 3
9 Climate vs. ventilation ->Why worry about the climate? Heating CO 2 NH 3 Humidity Light Noise Temperature Dust Ventilation Climate
10 Animal Demands At more than 26C we will see a drop in production Aarnink et al, 2006
11 Remove excess heat
12 CO 2 CO 2 CO 2 CO 2 CO 2 CO 2 Max 3000 ppm CO 2
13 Sensitivity to climatic stress* *) Climatic stress: Temperature fluctuations High CO 2 High NH 3 Chill turing into draft Very sensitive Less sensitive
14 Behaviour - comfort Control of body temperature Build nests Slushing for cooling Resting behaviour Important indicator for the well being of the pigs
15 Behavior social relations Ranking Normal behavior Stress related Abnormal behavior
16 SKOV A/S in Glyngoere approx. 11,000 m2
17 SKOV a complete Company
18 R & D Development of systems Mechanical construction Development of hardware Development of software 56 employees 8-10% of turnover is spent on development and research Cooperation with universities and agricultural research centres
19 Technologies Air Physics, own Test Centre
20 Technologies - mechanical Construction
21 Technologies Software Development
22 SKOV Global Support
23 SKOV Your Partner: Advising We make a dedicated solution that fits you and your animals requirements
24 Different type of ventilation systems Low Power Ventilation (LPV) Combi Tunnel Tunnel
25 Climate date from Vietnam Hanoi and Ho Chi Minh
26 Local climate: Hanoi Local climate: MeteoNorm Climate database Access to climate data s from more than locations around the world. Hourly based information s on temperature, humidity etc. from every single location. Hanoi: Data s are collected over a number of years and statistically treated ( meaning no single day peaks from last summer ) Temperature profile
27 Calculation based on StaldVent with special Skov module Calculations : House and Production figures : Number and size of animal. Production form and batch length Temperature, humidity and CO 2 strategy How are the animals kept inside the house Size of house and insulation values Kind of ventilation and cooling system. Different calculations : Climate conditions in LPV mode Climate conditions in tunnel mode Heating requirements Effect of cooling Yearly electricity consumption.
28 6413 House 10mx38mx2.4m(Weaner)
29 Power consumption and running hours, Weaners Tunnel: 3575h LPV: 4657h
30 6413 House 14.6mx60mx2.4m(Gestation)
31 Power consumption and running hours, gestation Tunnel: 6022h LPV:2714h
32 Yearly energy consumption Section kwh/year Temperature, setpoint,c Gestation Weaners >22
33 LPV systems: DA 1200 and DA 1540
34 Tunnel ventilation pig houses Regulation of ceiling and wall inlets in smaller sections Emergency opening requires 24V Can operate max. 16 wall inlets of the type DA 1200 Designed for the harsh house environment Stands heavy cleaning Can be used together with all SKOV climate computers
35 Combi tunnel systems for hot / cold areas
36 Combi-Tunnel System Drawing - Wall Fans
37 Combi-Tunnel System Drawing - Outlets
38 Air distribution in cold periods
39 Tunnel Ventilation
40 Airflow during hot weater0
41 Dol 534 / Dol 539 Climate Controller Climate functions PID regulation technology MultiStep fan control Two-zone control Cycle-time control of the ventilation Control according to outside temperature CO 2 and NH 3 recording Cooling control RST (roof - side - tunnel) ventilation Trend and batch curves Comprehensive alarm functions
42 Language on the controller in Viet and many more
43 Pigs can always perform the trick is to make sure the performance is optimal.
BlueFan High performance. Energy efficient. Intelligent design. Long durability.
BlueFan High performance. Energy efficient. Intelligent design. Long durability. Climate for Growth HIGH PERFORMANCE ENERGY EFFICIENT INTELLIGENT DESIGN LONG DURABILITY Until now you have had to choose
More informationEnergy-Efficient Ventilation for Pig Production
Energy-Efficient Ventilation for Pig Production Climate for Growth Energy-Efficient Ventilation Ventilation is a must when it comes to creating a healthy livestock house environment and providing optimal
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 11 DESIGN COOLING DESIGN HEATING COOLING DATA AT Dec 1700 HEATING DATA AT DES HTG COOLING OA DB / WB 33.1 C / 23.5 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 6 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1600 HEATING DATA AT DES HTG COOLING OA DB / WB 34.5 C / 23.7 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 1400 HEATING DATA AT DES HTG COOLING OA DB / WB 34.5 C / 23.7 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent
More informationNatural Ventilation in Schools and Commercial Buildings (CPD No. 31) Issue 2 May 2017
Natural Ventilation in Schools and Commercial Buildings (CPD No. 31) Issue 2 May 2017 Passivent Passivent Accreditations ISO 14001 Environmental Management OHSAS 18001 Health and Safety ISO 9001 Quality
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 3 Project Name: Av. Cabildo 3067, 4 piso 02/13/2011 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1500 HEATING DATA AT DES HTG COOLING OA DB / WB 34.9 C / 23.8
More informationHourly Analysis Program v.4.1 Page 1 of 1
Air System Design Load Summary for Zona 8 DESIGN COOLING DESIGN HEATING COOLING DATA AT Dec 1700 HEATING DATA AT DES HTG COOLING OA DB / WB 33.1 C / 23.5 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent
More informationEnergy-efficient ventilation for poultry
Energy-efficient ventilation for poultry Climate for Growth Energy-efficient ventilation Ventilation is a must when it comes to creating a healthy livestock house environment and providing optimal conditions
More informationEnergy Effort of Air Distribution Systems
Energy Effort of Air Distribution Systems F. Kolarik Content Introduction Energy effort of air distribution systems Method of calculation Example Further investigations Introduction Increasing requirements
More informationTHE EFFICACY OF VIUSID VET ON SWINE PRODUCTION IN VIETNAM
THE EFFICACY OF VIUSID VET ON SWINE PRODUCTION IN VIETNAM INTRODUCTION Viusid is a nutritional preparation, composed of antioxidants, vitamins, trace elements and an active substance from liquorice root
More informationAir distribution and temperature control in classrooms
Air distribution and temperature control in classrooms Jarek Kurnitski D.Sc., Docent HELSINKI UNIVERSITY OF TECHNOLOGY Laboratory of Heating, Ventilation and Air Conditioning Swegon Air Academy 11.6.2008
More informationPRINCIPLES AND POTENTIALS OF VENTILATIVE COOLING
PRINCIPLES AND POTENTIALS OF VENTILATIVE COOLING PER HEISELBERG OPERATING AGENT IEA EBC ANNEX 62 BACKGROUND THE CURRENT DEVELOPMENT TOWARDS NEARLY- ZERO ENERGY BUILDINGS HAVE LEAD TO AN INCREASED NEED
More informationIMPACT OF FREQUENCY OF FEEDLINE SOAKING COMBINED WITH EVAPORATIVE AIR COOLING IN A HUMID ENVIRONMENT
Dairy Research 2005 IMPACT OF FREQUENCY OF FEEDLINE SOAKING COMBINED WITH EVAPORATIVE AIR COOLING IN A HUMID ENVIRONMENT M. J. Brouk, J. F. Smith, D. V. Armstrong, M. J. VanBaale, D. R. Bray, and J. P.
More informationOptimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models
L. Pagliano et al, I: Optimization of air tightness and night ventilation for Passive houses in Italian climates... 1 Optimization of air tightness and night ventilation for Passive houses in Italian climates
More informationMonitoring of Advanced Facades and Environmental Systems
Paper presented at The whole-life performance of facades University of Bath, CWCT, 18/19 April 2001, Bath, UK Monitoring of Advanced Facades and Environmental Systems Mikkel Kragh, PhD Permasteelisa Architectural
More informationMany issues to consider when planning & designing a new dairy facility- Process Flows Water Flow Land Flow Manure Flow Cow Flow Feed Flow Traffic Flow
Many issues to consider when planning & designing a new dairy facility- Process Flows Water Flow Land Flow Manure Flow Cow Flow Feed Flow Traffic Flow Systemic Personnel Flow Visitor Flow Growth (future)
More informationCASE STUDIES - CENTRE FOR SUSTAINABLE BUILDING (ZUB) KASSEL, GERMANY
CASE STUDIES - CENTRE FOR SUSTAINABLE BUILDING (ZUB) KASSEL, GERMANY This office building was built as an extension to an older already existing building. An atrium with staircases and hallways connects
More informationDA Global Distributor Meeting Partnership for Growth SKOV Global Distributor Meeting 2017
DA 1700 Global Distributor Meeting 2017 Why 9 billion people in 2050 Restricted resources require higher efficiency We must contribute to effective global food production in consideration of animals, humans
More informationEstablishing ammonia emission factors for shallow pit, fully-slatted finisher buildings
Establishing ammonia emission factors for shallow pit, fully-slatted finisher buildings Summary Ammonia (NH3) emissions levels determined for a fully slatted, shallow pit (
More informationTHERMAL POWER PLANT SIMULATOR TPP 200 LABORATORY EXERCISE TUTORIAL N4: INTRODUCTION TO THE HEAT PRODUCTION SYSTEM
EKV THERMAL POWER PLANT SIMULATOR TPP 200 LABORATORY EXERCISE TUTORIAL N4: INTRODUCTION TO THE HEAT PRODUCTION SYSTEM Master of Science Thesis Division of Heat and Power Technology 2003 Department of Energy
More informationFIRST LARGE-SCALE SOLAR SEASONAL BOREHOLE THERMAL ENERGY STORAGE IN CANADA
FIRST LARGE-SCALE SOLAR SEASONAL BOREHOLE THERMAL ENERGY STORAGE IN CANADA W.P. Wong, J.L. McClung Science Applications International Corporation (SAIC Canada) Ottawa, ON Canada Tel: 1-613-563-7242 bill.wong@saiccanada.com
More informationReducing Energy Costs in Swine Barns
Reducing Energy Costs in Swine Barns B. Predicala, E. Navia, L. Whittington, J. Patience Prairie Swine Centre Inc. Saskatoon, Saskatchewan 26 September 2007 Presentation Outline Background Project Objectives
More informationSet Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.
Set Free Modular FSXN Engineering for tomorrow. And the tomorrow after that. 0 03 Introducing a new addition to Hitachi s Set Free range of VRF air conditioning units - enhancing efficiency and user experience
More informationGive the Best Customer Experience in our Industry: The Best Project Delivery Performance. This applies to both the SKOV Team and SKOV Distributors
Introduction Give the Best Customer Experience in our Industry: The Best Sales Support The Best Project Delivery Performance The Best After-Sales Service This applies to both the SKOV Team and SKOV Distributors
More informationNATIONAL ANIMAL WELFARE STANDARDS CHICKEN MEAT INDUSTRY FOR THE. Manual for Meat Chicken Farming
NATIONAL ANIMAL WELFARE STANDARDS FOR THE CHICKEN MEAT INDUSTRY Manual for Meat Chicken Farming Note: For industry use only. National Animal Welfare Standards for the Chicken Meat Industry, Manual for
More informationInterventions in the Indonesian broiler sector: effects of management and housing conditions on results. Dr. Rick van Emous & Dr.
Interventions in the Indonesian broiler sector: effects of management and housing conditions on results Dr. Rick van Emous & Dr. Sander Lourens Interventions in the Indonesian broiler sector: effects of
More informationConfinement Sow Gestation and Boar Housing
Confinement Sow Gestation and Boar Housing Originally published as PIH-28. Authors: Gilbert R. Hollis, Texas A & M University L. Bynum Driggers, North Carolina State University Arthur J. Muehling, University
More informationApplications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi
Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi (1) Wei-Hwa Chiang (2) Nguyen Ngoc Tu (3) Jian Sheng Huang (1)whch@mail.ntust.edu.tw (2)M9602806@mail.ntust.edu.tw
More informationChapter 7. Passive Solar Contents
Chapter 7. Passive Solar Contents 7.1 Introduction 7.2 Types of Passive Solar Systems 7.3 Advantages and Disadvantages 7.4 General Design Principles 7.5 Design Information for Direct System 7.6 Design
More informationSimulation of Heat Requirement and Air Quality in Weaner Houses for Three Climate Regions Using CIGR 2002 Heat Production Equations
1 Simulation of Heat Requirement and Air Quality in Weaner Houses for Three Climate Regions Using CIGR 2002 Heat Production Equations S. Pedersen, S. Morsing & J.S. Strøm Danish Institute of Agricultural
More informationDoes NZEB pose a conflict to Good Indoor Air Quality? REHVA summit November 2017
Does NZEB pose a conflict to Good Indoor Air Quality? REHVA summit November 2017 Version: 2016-07-04 Niels Christensen Strategic Product Manager, ICS Email: niels.christensen@lindab.com Version: 2016-07-04
More informationDISPLACEMENT VENTILATION
DISPLACEMENT VENTILATION D3 OVERVIEW The fundamental approach to displacement ventilation utilizes the natural buoyancy forces created by the convective flows from heat sources in the space. As supply
More informationMODULE #5 MECHANICAL, ELECTRICAL, PLUMBING II
MODULE #5 MECHANICAL, ELECTRICAL, PLUMBING II MICHAEL WALSH PRINCIPAL, R.G. VANDERWEIL ENGINEERS, LLP 274 Summer Street, Boston, MA 02210 (T) 617-423-7423 (F) 617-423-7401 mwalsh@vanderweil.com Module
More informationThe German Sustainable Building Certification System DGNB Best Practice Examples from Thailand. Dr.-Ing. Robert Himmler Bangkok, Thailand
The German Sustainable Building Certification System DGNB Best Practice Examples from Thailand Dr.-Ing. Robert Himmler 25.09.2017 Bangkok, Thailand Sustainable buildings and neighborhoods Theory and Practice!
More informationSET. An analysis of thermal comfort in primary schools in Vietnam BOLOGNA. Thi Ho Vi LE 1, Mark GILLOTT 2, Lucelia RODRIGUES 3
SET 2017 BOLOGNA An analysis of thermal comfort in primary schools in Vietnam Thi Ho Vi LE 1, Mark GILLOTT 2, Lucelia RODRIGUES 3 1 University of Nottingham, Nottingham, United Kingdom, vi.le@nottingham.ac.uk
More informationYour Zero Energy Ready Home Story
Your Zero Energy Ready Home Story BROUGHT TO YOU BY United Way of Long Island (631) 940-3721 - rwertheim@unitedwayli.org Once upon a time new homes too often missed opportunities to leverage advanced technology
More informationOperating Engineers Seminar Bob Ford Jeff Volovsek
Operating Engineers Seminar 2017 Bob Ford Jeff Volovsek Overview Annual energy consumption to demand Heat recovery updated requirements Process cooling best practices How does District Energy compare?
More informationMechanical vs. Natural Ventilation in Schools: Less Can Be More
Mechanical vs. Natural Ventilation in Schools: Less Can Be More Brad Stanley Purafil, Inc. Seminar 5 -Natural Ventilation in Schools: Boon or Bust? ASHRAE Annual Meeting Long Beach, California June 24-27,
More informationWork Package 2: Performance of naturally ventilated buildings
Work Package 2: Performance of naturally ventilated buildings Detailed Monitoring Report BRE Energy Efficient Office of the Future (GB1) M K White, M Kolokotroni, R Shaw, J Pike, C Ni Riain and MDAES Perera
More informationCompany DUOL. Dušan Olaj CEO
Company DUOL Company DUOL has been active on the market since 1992 and throughout this period Duol has successfully attained the position of one of the most significant suppliers of fabric structures.
More informationThe Centre for Sustainable Building (ZUB) * A Case Study
The Centre for Sustainable Building (ZUB) * A Case Study Dietrich Schmidt Tekn. Lic. 1,2 1 KTH-The Royal Institute of Technology. Division of Building Technology. Brinellvägen 34. SE-100 44 Stockholm.
More informationAdditional Information on Default Values
Additional Information on Default Values 1 Default values for boilers and chillers for the reference emission calculation For projects introducing high efficiency boilers and heat recovery heat pumps,
More informationFigure 1. Basic principle of ventilation: fresh air mixes with shelter air contaminants and is discharged. CONTAMINATED AIR OUT MOISTURE MIXING GASES
Effective Natural Ventilation Strategies By Curt A. Gooch, P.E. Senior Extension Associate Agricultural and Biological Engineering PRO-DAIRY Program Cornell University Introduction What is the function
More informationMODELING AND VALIDATION OF EXISTING VAV SYSTEM COMPONENTS
MODELING AND VALIDATION OF EXISTING VAV SYSTEM COMPONENTS Nabil Nassif Stanislaw Kajl Robert Sabourin École de technologie supérieure Montreal, Canada nnassif@mec.etsmtl.ca skajl@mec.etsmtl.ca Robert.Sabourin@etsmtl.ca
More informationPassive House Northwest AIA CEU Provider
Passive House Northwest AIA CEU Provider Multifamily Ventilation Strategies Workshop AIA Course # phnw Matt Groves, Albert Rooks March 11, 2016 Credit(s) earned on completion of this course will be reported
More informationAssessing Options for Ventilating Adult Cow Barns Making Sense of Too Many Choices!
Assessing Options for Ventilating Adult Cow Barns Making Sense of Too Many Choices! Nigel B. Cook MRCVS University of Wisconsin-Madison School of Veterinary Medicine 2015 Linden Drive, Madison, WI 53706
More informationCAE 331/513 Building Science Fall 2017
CAE 331/513 Building Science Fall 2017 November 14, 2017 Heating load calculations Advancing energy, environmental, and sustainability research within the built environment www.built-envi.com Twitter:
More informationEnergy savings in commercial refrigeration. Low pressure control
Energy savings in commercial refrigeration equipment : Low pressure control August 2011/White paper by Christophe Borlein AFF and l IIF-IIR member Make the most of your energy Summary Executive summary
More informationYou Can t Afford Discomfort. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas
You Can t Afford Discomfort Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Where We Are Today: So You Want To Save Money? Things to consider: 1. First Cost 2. Energy cost 3. Occupant Salary costs
More informationBuilding Technology Research in Architectural Practice: Lessons Learned from Implementations of Energy-Efficient Advanced Building Technologies
Building Technology Research in Architectural Practice: Lessons Learned from Implementations of Energy-Efficient Advanced Building Technologies Ajla Aksamija and Abul Abdullah, Perkins+Will ABSTRACT This
More informationObjectives of NatVent
of! This seven nation pan European project aims to reduce primary energy consumption (and consequently CO2 emissions) in office type buildings by: (a) providing solutions to barriers which prevent the
More informationManaging Variable Costs on Dairy Farms Through Energy Use Assessment and Conservation
Managing Variable Costs on Dairy Farms Through Energy Use Assessment and Conservation Acknowledgements Program Support Project supported by USDA/NIFA under Award Number 2012 49200 20032 North Central Risk
More information6.2.1 Intermediate Pumping Overview
6.2.1 Intermediate Pumping Overview The intermediate pumps are the feed pumps to the MBR system. The pumps take flow from the primary effluent channel and pump it to the channel in front of the fine screens.
More informationChilled Beams. The new system of choice?
Chilled Beams The new system of choice? Presented By: Kevin M. Pope P.E. Jason Leffingwell Hammel Green And Abrahamson, Inc. and Ken Bauer, P.E., LEED AP Butters-Fetting Co., Inc. History of Chilled Beams
More informationThe Environment in Swine Housing
The Environment in Swine Housing Originally published as PIH-54. Introduction Author Steven J. Hoff, Iowa State University Reviewers George Grandle, University of Tennessee Robert Bottcher, North Carolina
More informationDemonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy
Demonstration of modeling of radiant cooling system in design builder Prashant Bhanware & Bharath Reddy CONTENTS Introduction to Design Builder Building Energy Simulation Modeling procedure Making a model
More informationCalf house Ventilation
Section 5 Introduction Adequate calf house ventilation is vital to promote the growth of healthy calves. Successful calf house ventilation helps to reduce the risk of pneumonia outbreaks and increases
More informationDeveloping, Financing and Investing in Solar PV Projects in Lower Mekong Countries Workshop
VIETNAM MINISTRY OF INDUSTRY AND TRADE Developing, Financing and Investing in Solar PV Projects in Lower Mekong Countries Workshop Regulatory framework for solar PV in Viet Nam and discussion on Decision
More informationA Solar Wall System Utilized in Rural Houses of Northeast China
A Solar Wall System Utilized in Rural Houses of Northeast China Tiantian Zhang and Yufei Tan in rural buildings, for instance, only 16.4% of the investigated houses employ solar energy to produce hot water
More information07059, Antalya / TURKEY ABSTRACT
1 The Effects of Natural Ventilation Air Exchange on Psychrometric Results in Poultry Houses in Hot Environment---Design Characteristics S. Mutaf 1, S.Alkan 1, N.Seber 1 1 Akdeniz University, Faculty of
More informationThe Low Energy Ventilation Company. Fiona Dickinson, Consulting Engineer 21 st May 2013
The Low Energy Ventilation Company Fiona Dickinson, Consulting Engineer 21 st May 2013 Contents Building Energy Usage Traditional Natural Ventilation Approach Examples of Natural Ventilation Designing
More informationUSER MANUAL STRUCTURE APAT
USER MANUAL STRUCTURE OBJECTIVES: Lead the applicant through the application process; 1 Help the Competent Body with the evaluation of the application and the verification of compliance to the criteria
More informationEnergy Efficiency. best in class
Page 1 The impact of Building Automation on Energy Efficiency Siemens with DESIGO and Synco best in class Energy is a major issue for the European Union Primary energy use in Europe Dependency Without
More information19 A New Prefabricated 3,200 Sow Pig Unit and its Environmental Impact Assessment
19 A New Prefabricated 3,200 Sow Pig Unit and its Environmental Impact Assessment Jorge F Meneses, CEER, Instituto Superior de Agronomia, Portugal A new 3,200 sow prefabricated pig unit was built this
More informationAnalysis of Thermal Comfort Conditions and Actual Energy Efficiency for Different Heating Systems in Test Buildings
Proceedings of REHVA Annual Conference 15 Advanced HVAC and Natural Gas Technologies Riga, Latvia, May 9, 15 Analysis of Thermal Comfort Conditions and Actual Energy Efficiency for Different Heating Systems
More informationEnergy Recovery Process Cooling Example. Presentation - Overview. Air Change Australia Pty Ltd. Air Change Energy Recovery Range
2 Presentation - Overview Energy Recovery Range + Designing Plant Rooms for Energy Efficiency The Company and the Technology Energy Recovery Product Range Product Range Pre-conditioners vs ERV-AHU s Energy
More informationIndoor environment for energy performance of buildings a new European draft standard
International Conference Passive and Low Energy Cooling 1109 Indoor environment for energy performance of buildings a new European draft standard O. Seppänen Helsinki University of Technology, Finland
More informationNATURAL VENTILATION COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING
NATURAL VENTILATION COMMERCIAL BUILDINGS A guide to Natural Ventilation, including our unique solution offerings, consultancy service and recommendations. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk
More informationWELCOME by Jasper van den Munckhof
DESIRABLE, WARM AND AFFORDABLE HOMES FOR LIFE. Energiesprong A Movement for Change Energiesprong UK Rosemary Coyne WELCOME by Jasper van den Munckhof Funded by the European Union This project has received
More informationChildren thermal comfort in primary schools in Ho Chi Minh City in Vietnam
Children thermal comfort in primary schools in Ho Chi Minh City in Vietnam Thi Ho Vi Le 1, 2, Mark Gillott 1 and Lucelia Rodrigues 1 1 Faculty of Engineering, University of Nottingham, Nottingham, United
More informationCHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
More informationNATIONAL ANIMAL WELFARE STANDARDS CHICKEN MEAT INDUSTRY FOR THE. Manual for Breeder Production
NATIONAL ANIMAL WELFARE STANDARDS FOR THE CHICKEN MEAT INDUSTRY Manual for Breeder Production Note: For industry use only. National Animal Welfare Standards for the Chicken Meat Industry, Manual for Breeder
More informationCooling coil optimisation in hot and humid climates for IAQ and energy considerations
Cooling coil optimisation in hot and humid climates for IAQ and energy considerations Chandra Sekhar 1, Uma Maheswaran 2 1 Department of Building, National University of Singapore 2 Jurong Consultants
More informationXVII th World Congress of the International Commission of Agricultural and Biosystems Engineering (CIGR)
XVII th World Congress of the International Commission of Agricultural and Biosystems Engineering (CIGR) Hosted by the Canadian Society for Bioengineering (CSBE/SCGAB) Québec City, Canada June 13-17, 2010
More informationLivestock climate control systems as a potential ammonia abatement technique
Livestock climate control systems as a potential ammonia abatement technique N. Kozlova, N. Maximov North-West Research Institute of Agricultural Engineering and Electrification (SZNIIMESH) Saint-Petersburg,
More informationIN THIS ISSUE INTRODUCTION BACKGROUND. March 2018 High Humidity in Winter: Analysis for Multi-Family Passive House Projects
Page 1 High Humidity in Winter: Analysis for Multi-Family Passive House Projects IN THIS ISSUE Passive House for multi-family residential applications Analysis of high humidity levels in winter Impact
More informationFlexible Operation. Integrating thermal power with Renewable Energy & Challenges. Y M Babu Technical Services, Noida
Flexible Operation Integrating thermal power with Renewable Energy & Challenges 1 Y M Babu Technical Services, Noida Why Flexible Operation? Limitations with Renewable generation has called for flexible
More informationENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE
Bulletin of the Transilvania University of Braşov Vol. 3 (52) - 2010 Series I: Engineering Sciences ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE M. MOLDOVAN 1 I. VIŞA 1 A. DUŢĂ 1 Abstract: Into
More informationBUILDING INTEGRATED VENTILATION SYSTEMS MODELLING AND DESIGN CHALLENGES
BUILDING INTEGRATED VENTILATION SYSTEMS MODELLING AND DESIGN CHALLENGES P. Heiselberg Ph.D. 1 ABSTRACT Today, attention has turned towards optimal use of sustainable technologies like natural ventilation.
More informationSimulation Studies on Performance of Solar Cooling System in UAE Conditions
Available online at www.sciencedirect.com Energy Procedia 00 (2014) 000 000 www.elsevier.com/locate/procedia SHC 2013, International Conference on Solar Heating and Cooling for Buildings and Industry September
More informationStoves 101. Basic Stove Science for the Non-scientist (With Jokes) Dale Andreatta, Actual Scientist (mechanical engineer, actually)
Stoves 101 Basic Stove Science for the Non-scientist (With Jokes) Dale Andreatta, Actual Scientist (mechanical engineer, actually) Britt Andreatta (no relation) says: Don t max the hippo! The Scientific
More informationApplication technology, 5th edition. Volume III: Fonterra radiant heating and cooling
Application technology, 5th edition Volume III: Fonterra radiant heating and cooling Fonterra Active General Fonterra Active General Fonterra Active was developed specifically for thermal activation of
More informationOn the performance of confluent jets ventilation system in office space
On the performance of confluent jets ventilation system in office space T. Karimipanah 1 and B. Moshfegh 1, 2 1 Division of Energy and Mechanical Engineering, Department of Technology and Built Environment,
More informationEnergy Simulation And Optimized Retrofit Practices Applied To A Real Dwelling
Purdue University Purdue e-pubs International High Performance Buildings Conference School of Mechanical Engineering 2014 Energy Simulation And Optimized Retrofit Practices Applied To A Real Dwelling Giulia
More informationHVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya
HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya (vahid.vakiloroaya@engineer.com) ABSTRACT: The overall attainable reduction in energy consumption and enhancement of
More informationPASSIVHAUS Designed for you to enjoy maximum comfort with minimum energy.
PASSIVHAUS Designed for you to enjoy maximum comfort with minimum energy. + Energy efficiency + Savings +Comfort WHAT IS PASSIVHAUS? The Passivhaus (Passive House) standard is the most stringent international
More informationThe Barn: New Building or Renovation? Murray Elliott, FGC Limited Steve Beadle, OMAFRA
The Barn: New Building or Renovation? Murray Elliott, FGC Limited Steve Beadle, OMAFRA Group Sow Housing Seminar September 7, 2016 Stratford, Ontario Decisions to Make. New Code of Practice requires group
More informationROOF TOP SPACE. SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA C
C O M F O R T A I R Q U A L I T Y E N E R G Y O P T I M I S A T I O N ROOF TOP SPACE SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA. 0816 C SPACE
More informationFor all those with the ability to influence the design, layout or indoor air quality of buildings
Natural Selection For all those with the ability to influence the design, layout or indoor air quality of buildings By the end of this presentation you will:- Understand what Natural Ventilation is. Know
More informationLong-term monitoring and smart heat pumps for nzeb
Long-term monitoring and smart heat pumps for nzeb Franziska Bockelmann Christina Betzold Berghalde 1. Monitoring results 2. Optimization: increase of self supply Implementation building Systemsimulation
More informationEnergy-Efficient Passive House using thermal mass to achieve high thermal comfort
Energy-Efficient Passive House using thermal mass to achieve high thermal comfort Loa Andersson Managing Director RLI Byggdata AB rli@termodeck.com Alexander Engström Technical Director RLI Byggdata AB
More informationLarge University Central Chiller Plant Design Considerations
Carrier Engineering Newsletter Volume 5, Issue 3 Large University Central Chiller Plant Design Considerations Large campus chilled water plants have unique constraints and need careful evaluation for successful
More informationguidance Energy Set-Points Step 1: Team assignment Step 2: Inventory of equipment set points and controls
guidance Energy Set-Points Nearly every piece of equipment has a control system. Plant engineers and managers must ensure they are programmed properly. This guidance document is meant to help the brewer
More informationRetail Effects of ANSI/ASHRAE/IES Standard
Retail Effects of ANSI/ASHRAE/IES Standard 90.1-2016 Prepared by Dialectic Inc. INTRODUCTION Background ANSI/ASHRAE/IES 90.1-2016 Energy Standard for Buildings Except Low-Rise Residential Buildings replaces
More informationMinisterio Público Fiscal de la Ciudad de Buenos Aires Fiscalía General Departamento de Infraestructura y Apoyo Operativo
Air System Design Load Summary for Zona 1 Project Name: Av. Cabildo 3076, 4 piso 04/05/2011 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1500 HEATING DATA AT DES HTG COOLING OA DB / WB 34.9 C / 23.8
More informationModelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates
Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates Kittitach Pichatwatana, and Fan Wang Abstract This paper examines the TAS computer
More informationDesigning Maintenance Garages for Energy Savings
Designing Maintenance Garages for Energy Savings Overview Typical H&V design for a maintenance garage Discuss problems associated with the typical system and what led to another approach Modified design
More information> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories
> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS
More informationControls and Software CHORE-TRONICS 2 Controls
Controls and Software 2 Controls Chore-Time s Controls and Software Make House Management Easier and More Convenient Dependable hardware technology and software algorithms Chore-Time s Controls are industry
More information