3.1 Rev Features. Horizon. Materials and Specifications. Horizontal Turbine Meters Sizes 1-1/2", 2"
|
|
- Philip Dorsey
- 6 years ago
- Views:
Transcription
1 Features APPLICATIONS: For use in the measurement of potable water for applications where flow is consistently moderate to high. Designed for applications where accuracy is an essential part of maintaining revenue. The horizontal turbine meter is built to maintain accuracy over extended periods of use. CONFORMANC TO STANDARDS: turbine meters have some of the widest flow ranges of any turbine meters on the market. All series turbine meters meet or exceed the latest performance and accuracy standards of AWWA C71. Two inch meters have FM Approval. Maximum continuous flow rates may be exceeded by as much as 5% for intermittent periods. CONSTRUCTION: The consists of three basic parts; maincase; measuring insert; and register. Maincases are made of bronze. Measuring elements are thermoplastic with unique inlet and outlet straightening vanes. To simplify maintenance, the is designed to allow quick, easy, in-line exchange of the measuring element without removing the maincase from the installation. Interchangeability of many parts within various sizes minimizes spare parts inventory and the comes standard with built-in strainer. RGISTR: Permanently sealed register has a unique seal and heat-treated glass to eliminate dirt, moisture infiltration and lens fogging. An integral tamper-proof locking feature is provided to prevent tampering of the register and calibration vane. The totalizing register has a straight-reading odometer type display; 3º test circle with center sweep hand and a low flow (leak) detector. Standard gearing is used, making registers interchangeable by size. All Hersey meter Models have electronic meter reading systems available for increased reading efficiency (see Meter Reading Systems.) OPRATION: Water flows straight through the measuring element where it turns a rotor at a rate in direct proportion to the quantity of water flowing through the meter. The straight-through design allows high volumes to flow with a minimum of head loss. Retro Thrust design extends the life of the meter by dividing wear between two points: during low flow the tungsten carbide bearing in the rotor floats against a stainless steel shaft; during high flow a second tungsten carbide bearing gently moves back against another stainless steel shaft. During medium flow, the rotor floats between both tungsten carbide bearings with sapphire bushings providing radial support for the rotor. STRAINR & TST PORT: Standard Built-in Strainer. Test port is optional with spool piece. CONNCTIONS: ANSI Class 15 Flanges. 1-1/" NPT pipe threads on optional test outlet. Sizes 1-1/", " Materials and Specifications MODL DSIGNATION... HORIZON SIZS /", " STANDARDS... Manufactured and tested to meet or exceed all applicable parts of ANSI/AWWA C71 class II Standard. " meters have FM Approval. SRVIC... Cold water measurement. NORMAL OPRATING FLOW RANG... See Chart on page 3.. ACCURACY... See Chart on page 3.. PRSSUR LOSS... See Chart on page 3.. MAXIMUM WORKING PRSSUR PSI TMPRATUR RANG... 33F to F water temperature MASURING LMNT... Stainless Steel and Thermoplastic RGISTR TYP... Straight reading, permanently sealed, magnetic drive with low flow indicator. Remote Readings units optional. MATRIALS... Maincase bronze UNS ; Casing bolts Stainless steel ANSI B1; Rotor Thermoplastic; Rotor radial bearing Sapphire; Rotor thrust bearings tungsten carbide; Rotor bearing pivots Stainless steel ANSI B1; Magnet - rare earth/ceramic; Register box and lid Thermoplastic or optional bronze; Standard strainer Stainless steel; Spool piece with test outlet - bronze. INSTALLATION... tal or Vertical CONNCTIONS /" " ANSI Class 15 OPTIONS... AMR Reading Systems 3.1 Rev. 1-3
2 Sizes 1-1/", " Meter Registration Meter Size Initial Dial* Capacity Initial Dial* Capacity 1-1/" Gallons Million 1 Cubic Feet 1 Million " Gallons Million 1 Cubic Feet 1 Million *Registration equal to one full revolution of the sweep hand. Flow Characteristics Meter Size Typical Low Flow Typical Operating Range Maximum Continuous Maximum Intermittent (95% Minimum) (% ± 1.5%) Operation Flow 1-1/" GPM to 1 GPM 1 GPM 1 GPM " -1/ GPM to 1 GPM 1 GPM GPM Performance* 1-1/" HORIZON AWWA STANDARD AWWA STANDARD AND INTRNAL STRAINR Dimensions & Weights Meter Size 1-1/" " Dimension A Compact Length 9 1 AA Standard Length B Height 7-3/ 7-3/ C Centerline 1-3/ -1/ D Holes 3/ 3/ Width -1/ -1/ F Flange 3/ 3/ Net Weight Compact - LBS 3 Net Weight Standard - LBS.5 3 " HORIZON B D AWWA STANDARD AWWA STANDARD AND INTRNAL STRAINR A F C Rev. 1-3 AA
3 Features APPLICATIONS: For use in the measurement of potable water for applications where flow is consistently moderate to high. Designed for applications where accuracy is an essential part of maintaining revenue. The horizontal turbine meter is built to maintain accuracy over extended periods of use. CONFORMANC TO STANDARDS: turbine meters have some of the widest flow ranges of any turbine meters on the market. All series turbine meters meet or exceed the latest performance and accuracy standards of AWWA C71. meters in sizes 3"-1" are FM Approved. Maximum continuous flow rates may be exceeded by as much as 5% for intermittent periods. CONSTRUCTION: The consists of three basic parts; maincase; measuring insert; and register. Maincases are made of bronze. Measuring elements are thermoplastic with unique inlet and outlet straightening vanes. To simplify maintenance, the is designed to allow quick, easy, in-line exchange of the measuring element without removing the maincase from the installation. Interchangeability of many parts within various sizes minimizes spare parts inventory. Built - in test ports are standard for ease of field testing. RGISTR: Permanently sealed register has a unique seal and heat-treated glass to eliminate dirt, moisture infiltration and lens fogging. An integral tamper-proof locking feature is provided to resist tampering with the register or calibration vane. The totalizing register has a straight-reading odometer type display, a 3º test circle with center sweep hand and a low flow (leak) detector. Standard gearing is used, making registers interchangeable by size. All Hersey Meter Models have electronic meter reading systems available for increased reading efficiency (see Meter Reading Systems.) OPRATION: Water flows straight through the measuring element where it turns a rotor at a rate in direct proportion to the quantity of water flowing through the meter. The straight-through design allows high volumes to flow with a minimum of head loss. Retro Thrust design extends the life of the meter by dividing wear between two points: during low flow the tungsten carbide bearing in the rotor floats against a stainless steel shaft; during high flow a second tungsten carbide bearing gently moves back against another stainless steel shaft. During medium flow, the rotor floats between both tungsten carbide bearings with sapphire bushings providing radial support for the rotor. STRAINR: A separate optional strainer is recommended to protect the measuring element. CONNCTIONS: ANSI Class 15 Flanges on 3" through 1" sizes; " NPT pipe threads on test outlet. Sizes 3", ", ", ", 1" Materials and Specifications MODL DSIGNATION... HORIZON SIZS... 3", ", ", ", 1" STANDARDS... Manufactured and tested to meet or exceed all applicable parts of ANSI/AWWA C71 class II Standard. 3"-1" meters are FM Approved SRVIC... Cold water measurement with flow in one direction. OPRATING FLOW RANG... See Chart on page ACCURACY... See Chart on page PRSSUR LOSS... See Charts on pages MAXIMUM WORKING PRSSUR PSI TMPRATUR RANG... 33F to F water temperature MASURING LMNT... Stainless Steel and Thermoplastic RGISTR TYP... Straight reading, permanently sealed, magnetic drive with low flow indicator. Remote Readings units optional. MATRIALS... Maincase bronze UNSC; Casing bolts Stainless steel ANSI B1; Rotor Thermoplastic; Rotor radial bearing Sapphire; Rotor thrust bearings tungsten carbide; Rotor bearing pivots Stainless steel ANSI B1; Magnet - rare earth/ceramic; Register box and lid Thermoplastic or optional bronze. INSTALLATION... tal or Vertical CONNCTIONS... 3" 1" ANSI Class 15 OPTIONS... AMR Reading Systems 3.3 Rev. 1-3
4 Sizes 3", ", ", ", 1" Meter Registration Meter Size Initial Dial* Capacity Initial Dial* Capacity 3" Gallons Million 1 Cubic Feet 1 Million " Gallons Million 1 Cubic Feet 1 Million " Gallons 1 Billion Cubic Feet Million " Gallons 1 Billion Cubic Feet Million 1" Gallons 1 Billion Cubic Feet Million *Registration equal to one full revolution of the sweep hand. Flow Characteristics Meter Size Typical Low Flow Typical Operating Range Maximum Continuous Maximum Intermittent (95% Minimum) (% ± 1.5%) Operation Flow 3" 3 GPM to GPM GPM 75 GPM " GPM to GPM GPM 15 GPM " 9 GPM 15 to GPM GPM GPM " 1 GPM 3 to 35 GPM 35 GPM GPM 1" 3 GPM to 55 GPM 55 GPM 7 GPM Performance* 3" HORIZON " HORIZON AWWA STANDARD AWWA STANDARD AWWA STANDARD AWWA STANDARD " HORIZON " HORIZON AWWA STANDARD AWWA STANDARD Rev AWWA STANDARD AWWA STANDARD Copyright - A subsidary of Mueller Co. Printed in U.S.A
5 Performance* 1" HORIZON Sizes 3", ", ", ", 1" AWWA STANDARD AWWA STANDARD Dimensions & Weights Meter Size 3" " " " 1" Dimension A 1" 1" 1" " " AA 1" 1-1/" 7" 3" 3" B 1" 1-3/" 13-1/" 15-1/" 1" C 3-3/" -1/" 5-1/" -3/" " D 3/" 3/" 7/" 7/" 1" 7-1/" 9" 11" 13-1/" 1" F 3/" 7/" 7/" 1-1/" 1-3/1" Net weight Note: Length AA is with standard strainer. Weights are in pounds and are approximate. D B C A F AA 3.5 Rev. 1-3
452 Series Magnetic Drive Positive Displacement Disc Meters Size 1
Size 1 Features APPLICATIONS: Measurement of cold water for residential and small commercial applications where water volumes are low, and low flow sensitivity is important. CONFORMANCE TO STANDARDS: Hersey
More informationSOLICITATION OVERVIEW
Water Meters DUE: 9/22/14 SOLICITATION OVERVIEW The City of Irving is soliciting best value bids for: TITLE: Water Meters ITB Number: 022M-15F Commodity: 9991 Water Meters Due Date: 3:00 p.m., Monday,
More informationB. Stipulated Price (Lump Sum). If Contract is Stipulated Price Contract, payment for work is in this Section is included in total Stipulated Price.
Section 02526 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Water meters, submeters, and fire service meters. 1.02 MEASUREMENT AND PAYMENT A. Unit Prices 1. Measurement for water meters is on unit price
More informationSPECIFICATION. Category: Cold Water Meter Type: Ultrasonic Transit-Time Size: 2 12 Applicable AWWA Standard: C750. Version 2.18
SPECIFICATION Category: Cold Water Meter Type: Ultrasonic Transit-Time Size: 2 12 Applicable AWWA Standard: C750 Version 2.18 Master Meter, Inc. 101 Regency Parkway, Mansfield, TX 76063 T: 817-842-8000
More information30-30 SAN ANTONIO WATER SYSTEM SAN ANTONIO, TEXAS SPECIFICATIONS FOR COLD-WATER METERS FIRE-SERVICE TYPE REVISED APRIL 2005
30-30 SAN ANTONIO WATER SYSTEM SAN ANTONIO, TEXAS SPECIFICATIONS FOR COLD-WATER METERS FIRE-SERVICE TYPE REVISED APRIL 2005 1. SCOPE This specification covers cold water fire-service type meters in sizes
More informationSan Antonio Water System Material Standard Specifications
30-01 San Antonio Water System Material Standard Specifications 1. SCOPE This specification covers cold-water displacement meters one and one-half inches (1-1/2") and smaller in size designed for waterworks
More informationNOTICE OF DISCONTINUATION,
Sizes ", ", ", 6", 8", " NOTICE OF DISCONTINUATION, Effective May st Mueller Systems is discontinuing our current line of strainers. We will continue to offer our plate strainers on a first come, first
More informationThe written bid documents supersede any verbal or written prior communications between the parties.
March 15, 2017 INVITATION TO BID The Gwinnett County Board of Commissioners is soliciting competitive sealed bids from qualified suppliers for the Purchase of Water Meters on an Annual Contract with three
More information1. The sign in sheet from the Pre-Bid Meeting on February 13, 2018 at 1:00 P.M. is attached.
105 W. 2 nd Street Tuscumbia, AL 35674 T (256) 248-7030 F 1-866-225-7488 PROJECT: Water Meter Material Contract City of Ashville DWSRF # FS010200-01 ADDENDUM NO. One (1) DATE: February 15, 2018 TO: All
More informationLIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:
SERIES 4624B (Cast Iron - Replaces Series 4625 Models) Page 410.1 Issue K SERIES DESCRIPTION The Abrasive Liquid Series heavy duty internal gear pumps utilize hard parts in key wear areas, combined with
More informationVIKING BOLTED-LID BASKET-TYPE LINE STRAINERS
Page 642.1 LOW PRESSURE DROP EASY TO CLEAN LIGHT IN WEIGHT SMALL IN OVERALL DIMENSION VIKING QUALITY DUCTILE CONSTRUCTION Series Description Viking Bolted-Lid Simplex Strainers provide protection for your
More informationDorot Irrigation Meter
DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features
More informationDIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART
DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART (For Cast Iron and Concrete Pipes See Note at Right) Lay a straightedge on scales
More informationIron Check Valves & Y-Strainers Illustrated Index
Iron Check Valves & Y-Strainers Illustrated Index Iron Body Swing Check Valve Bronze Mounted or All Iron 125 lb. SWP 200 lb. CWP Iron Body Swing Check Valve Bronze Mounted 250 lb. SWP 500 lb. CWP Lead
More informationVIKING LID-EASE BASKET-TYPE LINE STRAINERS FEATURES
VIKING LID-EASE Section 640 Page 640. Issue C FEATURES LIGHT IN WEIGHT EASY TO CLEAN LOW PRESSURE DROP SMALL IN OVERALL DIMENSION VIKING QUALITY CONSTRUCTION IN ALUMINUM, CAST IRON, DUCTILE IRON OR STAINLESS
More informationHAMILTON TOWNSHIP MUNICIPAL UTILITIES AUTHORITY
HEIGHT TO REMOVE STRAINER ELEMENT D C G I E B H F J A Operating Characteristics Meter Normal Operating Range* AWWA Low Flow Maximum Size @100% Accuracy (±1.5%) Standard @95% Accuracy Intermittent Flow
More informationSECTION PACKAGE BOOSTER PUMP STATIONS
SECTION 331223 PACKAGE BOOSTER PUMP STATIONS Scope: The Contractor shall install a pump station at two locations to be determined by the Owner. These pump stations shall be designed to deliver flow to
More informationTURBINE METER SERIES FMT-S
TURBIN MTR SRIS FMT-S The best way to predict the future is to create it Introduction Typical metrological characteristics 2 1.5 The FMT-S turbine meters are robust and designed to perform on the highest
More informationPARTS & ACCESSORIES: BASKET-TYPE LINE STRAINERS FEATURES. Section 640 Page Issue I VIKING LID-EASE SIMPLEX STRAINERS
PARTS & ACCESSORIES: VIKING LID-EASE SIMPLEX STRAINERS Section 640 Page 640.1 Issue I FEATURES Light in weight Easy to clean Low pressure drop Small in overall dimension Viking quality construction in
More informationTURBINE WATER & FIRE HYDRANT METERS. BID OPENING: Monday, March 24, 2014
Department of Finance City Hall Room 105A, 30 Church Street Rochester, New York 14614-1281 www.cityofrochester.gov Bureau of Purchasing PRINTED NAME OF BIDDER TURBINE WATER & FIRE HYDRANT METERS Invitation
More informationUL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves
UL / FM TAPPING VALVE SECTION Rev. 2-15 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D.
More informationDIVISION 15- MECHANICAL Section Fire Pumps
DIVISION 15- MECHANICAL Section 15320 Fire Pumps 1.00 PART 1 -GENERAL 1.01 DESCRIPTION OF WORK: A. Provide pumps for fire suppression. 1.02 SECTION INCLUDES: A. Vertical Turbine Fire Pump RELATED DOCUMENTS:
More information12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS
TM 12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS The reliable pump people Performance Shown at 2000 PSID (138 BAR), 200 SSU (43 CST) 60 HZ: 870 1150 1750 3500 *Bi-metal construction only 50 HZ: 960 1450
More informationGoulds Two Stage, Horizontally Split Case Pump
Goulds 3316 Two Stage, Horizontally Split Case Pump 3316 Two Stage, Horizontally Split Case Pumps designed for boiler feed, mine dewatering and other applications requiring moderately high heads with a
More informationVENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...
VENTURI FLOWMETERS Your First Choice in Intelligent Flow Management... VENTURI FLOWMETERS Preso s complete line of Venturis offer reduced operating costs, proven accuracy, and great rangeability. Low permanent
More informationNUFLO Liquid Turbine Flow Meters
TECHNICAL SPECIFICATIONS NUFLO Liquid Turbine Flow Meters Accurate Flow Measurement In 957, this flow meter was developed with a tungsten-carbide shaft and bearing to withstand the rugged conditions of
More informationYARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505
Advanced construction features of this high pressure drop angle globe valve provide quality and long service life. FEATURES GENERAL APPLICATION In addition to continuous blowdown service, the Yarway high
More informationSPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S
SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...
More informationSECTION WATER SERVICE CONNECTIONS
SECTION 33 12 13 WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for domestic water service connections to buildings. 2. Corporation stop assembly. 3. Curb
More informationSD/SW/VS50 SD50 SW50 VS50
Performance RPM: 1550 Discharge: 1-1/2" Solids: 3/4" Wholesale Products Page: 7130-1 Section: Performance SD50 SW50 VS50 The curves reflect maximum performance characteristics without exceeding full load
More informationMark-II and Mark-IIE Turbo-Meters
Mark-II and Mark-IIE Turbo-Meters OIML SPECIFICATIONS OIML 1070 Metric Rev. 1 Mark-II and Mark-IIE Turbo-Meters are true axial flow turbine meters. The entire gas flow is directed through an annular area
More information12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping
MUELLER TAPPING MATERIALS AND SPECIALTY VALVES 12.1 Shaded area indicates change Rev. 7-16 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including
More informationTown of Cornwall Water & Sewer Utility Corporation
Town of Cornwall Water & Sewer Utility Corporation Minimum Standard of Acceptability for Water, Sewer & Sprinkler Connections At the time of application for water, sewer and/or sprinkler service the applicant
More informationCommercial & Industrial Large Water Meters
Commercial & Industrial Large Water Meters 1 Water Distribution System 2 Large Meter Family 3 Large Meter Family 4 Specifications Clean Water Applications Maximum Operating Temperature: 80 deg F Maximum
More informationSeries Sump and Sewage Systems
Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column
More informationD-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves
TAPPING VALVE MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D. PVC--Also outlet sealed
More informationWP-SDC COPPER CAN REGISTER WOLTMAN WATER METER
WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial
More informationPARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )
PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and
More informationHYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR
PERFORMANCE DATA Wholesale Products Page: 7140-1 Dated: August 2002 Supersedes: May 2002 RPM: 1550 Discharge: 2 Solids: 2 8 25 7 20 5 4/10 HP HEAD-METERS 4 HEAD-FEET 15 3 10 2 0 0 20 40 60 80 Capacity-U.S.
More informationSECTION PUBLIC WATER SERVICE CONNECTIONS
SECTION 33 14 14 PUBLIC WATER SERVICE CONNECTIONS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe and fittings for water service connections to small commercial, light industrial, and residential
More informationHPGR200 2 HP. Capacity-U.S. G.P.M.
Performance RPM: 3450 Discharge: 1-1/4" Solids: 2" Wholesale Products Page: 6710-1 Section: Performance 100 80 2 HP TOTAL HEAD IN FEET 60 40 20 0 0 10 20 30 40 50 Capacity-U.S. G.P.M. 60 The curves reflect
More informationTable of Contents Scope of Design. Scope of Design Materials Dimensions & Weights Orifice Capacities
Scope of Design CONSOLIDATED Type 1511 safety valves are designed for low pressure, steam heating boilers and steam generators as well as air service applications. Table of Contents Scope of Design......................1511.1
More informationSINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804
Model 3804 AURORA 3800 Series SINGLE STAGE END SUCTION PUMPS Distributed By: Flow-Tech Industries 4601 South Pinemont, Suite 100 Houston, Texas 77041 Phone: 713.690.7474 Fax: 409.882.0254 sales@flow-tech.com
More informationG O R M A N - R U P P P U M P S POSITIVE DISPLACEMENT ROTARY GEAR PUMPS. GRpumps.com
G O R M A N - R U P P P U M P S POSITIVE DISPLACEMENT ROTARY GEAR PUMPS GRpumps.com R O T A R Y G E A R P U M P S GORMAN-RUPP G SERIES PUMPS NOTE: Shown with optional head jacket 5 6 4 9 LONGER LASTING
More informationCITY OF BARTLETT 6400 STAGE ROAD BARTLETT, TENNESSEE 38134
CITY OF BARTLETT 6400 STAGE ROAD BARTLETT, TENNESSEE 38134 A. Keith McDonald, Mayor Mark Brown, Chief Administrator Officer Dick Phebus, Finance Director Bill Yearwood, Public Works Director INVITATION
More informationModel 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas
Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas Thermo Scientific insertion turbine flowmeters have provided highly accurate and repeatable flow measurements for large pipeline applications
More informationBALL VALVES SUPERIOR BALL VALVES WA SERIES (WELDED) WA Series Ball Valve. WAS Series Ball Valve (With Access Fitting)
BALL VALVES SUPERIOR BALL VALVES WA SERIES (WELDED) WAS Series (Welded with Access Fittings) Full Refrigeration Service Temperature Range of -40 F to +325 F. Forged Brass Body and Seal Cap. Design Working
More informationFigure 3. 1 ½ Nutating Disc with R-10 register
Principle of Operation Liquid enters a precision-machined chamber containing a disc which nutates (wobbles). The position of the disc divides the chamber into compartments containing an exact volume. Liquid
More informationBasket Strainers. Threaded. Basket. Strainers. Flanged Basket. Strainers
Basket Basket feature top removal of the screen. The screen is in the form of a basket, with a lifting handle, so that all particulate captured and retained by the screen can be easily removed for disposal.
More informationSeries A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100
Series A-C 9100 Single Stage Double Suction Large Split Case TECHNICAL Brochure BAC9100 TABLE OF CONTENTS Useful Pump Formulas 2 Pump Engineering Data 3 Materials of Construction 4 Exploded View 6 USEFUL
More informationSECTION SLUICE GATES
SECTION 11100 SLUICE GATES PART 1--GENERAL Fill in the blank with a short description of sluice gate usage, i.e., for isolation of wastewater, or for tank drainage, or for control of water surface. 1.01
More informationCONTINUED ON FOLLOWING PAGE
Date Description of Change Pages / Sections Modified ID 08/05/17 Entire document - mgl PART 1 - INTRODUCTION 1.1 This standard refers to the following plumbing specialties. A. Drains, B. Hydrant and Hose
More informationModel B. Thermostatic Control Valves. Typical applications
Thermostatic Control Valves Model B Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications
More informationRosemount 405 Compact Orifice Primary Element
Rosemount 405 Compact Orifice Primary Element SPECIFICATIONS Performance Discharge Coefficient Uncertainty TABLE 20. 405 Compact Orifice Primary Element Type 405C (Conditioning Compact) 405P (1)(2) (Standard
More informationModel B. Thermostatic Control Valves. Typical applications
Thermostatic Control Valves Model B Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications
More information[Amdt , 60 FR 50336, Sept. 28, 1995; 60 FR 54409, Oct. 23, 1995, as amended at 69 FR 3696, Jan. 26, 2004; 70 FR 56099, Sept.
Subpart K Specifications for Packagings for Class 7 (Radioactive) Materials 178.350 Specification 7A; general packaging, Type A. (a) Each packaging must meet all applicable requirements of subpart B of
More informationC Addressing Non-Revenue Water with Static Meters. Martin Casillas Director of Sales, US West Kamstrup
C715-18 Addressing Non-Revenue Water with Static Meters Martin Casillas Director of Sales, US West Kamstrup AWWA C715 Standard 3 AWWA C715 Standard Purpose: Define minimum requirements for potable cold
More information2 and 3 T-10 Turbo-Meters Turbine Meters for Accurate Gas Measurement. M-1083 Rev. 4
2 and 3 T-10 Turbo-Meters Turbine Meters for Accurate Gas Measurement M-1083 Rev. 4 GENERAL INFORMATION INTRODUCTION Invensys Energy Metering 2 and 3 T-10 Turbo- Meters were developed to meet the recognized
More information2 and 3 T-10 Turbo-Meters Turbine Meters for Accurate Gas Measurement. M-1083 Rev. 3
2 and 3 T-10 Turbo-Meters Turbine Meters for Accurate Gas Measurement M-1083 Rev. 3 GENERAL INFORMATION INTRODUCTION Invensys Energy Metering 2 and 3 T-10 Turbo- Meters were developed to meet the recognized
More informationAll definitions are defined according to ANSI/AWWA C b. Flanged Joint: The flanged and bolted joint as described in ANSI/AWWA C110/A21.10.
21-02 SAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR RESILIENT-SEATED GATE AND TAPPING VALVES FOR WATER SUPPLY SERVICE ANSI/AWWA C509-01 3 IN., 4 IN., 6 IN., 8 IN., 10 IN., 12 IN., 16 IN., & 20 IN. Revised
More informationTarget Inline Flowmeter
Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted
More informationQuality First! Independent Water Pumping Systems. SDSP Submersible Sump Pump
Quality First! TM SOLAR PUMPING PRODUCTS Independent Water Pumping Systems SDS Series Submersible Pumps SunPumps SDS series submersible pumps are highly efficient, low voltage, DC powered, diaphragm type
More informationDSC/DSCA3. EBARA Submersible Sewage Pumps Contents. Project: Model: Chk d: Date: Model
Contents Model 150DSC3 250x150DSCA3 350x250DSCA3 500x400DSCA3 200DSC3 300x150DSCA3 400x250DSCA3 600x500DSCA3 250DSC3 250x200DSCA3 350x300DSCA3 750x500DSCA3 300DSC3 300x200DSCA3 400x300DSCA3 750x600DSCA3
More informationSECTION ALUMINUM GATES
P.O. Box 1058 370 South Athol Rd. Athol, Massachusetts 01331 Phone: (978) 249-7924 Fax: (978) 249-3072 SECTION ALUMINUM GATES PART 1 GENERAL 1.01 SCOPE OF WORK A. The CONTRACTOR shall furnish all labor,
More informationPUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...
PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Series 600 Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series
More informationClose Coupled Sealless Pumps
Fybroc Division SERIES 2 ASME/ANSI SPECIFICATION B73.1 DIMENSIONS SERIES 26 SELF-PRIMING Close Coupled Sealless Pumps B U L L E T I N 2B1 FYBROC SERIES 2 CLOSE-COUPLED SEALLESS PUMPS Capacities to 60 GPM
More informationCharlottetown - Water & Sewer Utility Minimum Standard of Acceptability for Water, Sewer & Sprinkler Connections
Charlottetown - Water & Sewer Utility Minimum Standard of Acceptability for Water, Sewer & Sprinkler Connections At the time of application for water, sewer and/or sprinkler service the applicant shall
More informationSuitable for use in a variety of fluid systems.
Suitable for use in a variety of fluid systems. General Description Pipeline Wye Strainers are in thousands of applications in chemical, petroleum, pulp and paper, and utilities, as well as numerous commercial
More informationW ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.
W ST IND TRY FIR US ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS Certified to NSF/ANSI 372 www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 1600 SERIES Single Stage End Suction Pumps
More informationGoulds Multistage Process Pumps
Goulds 3355 Multistage Process Pumps Multiple nozzle orientations to fit your piping configurations. Radial Suction Configuration. Radial nozzles are rotatable at 90 increments. Goulds Model 3355 Multistage
More informationSubmersible Axial Flow Propeller Pumps
Submersible Axial Flow Propeller Pumps water wastewater flood control EBARA Fluid Handling an EBARA International Corporation company Features Watertight cable entry system prevents capillary action and
More informationRL Industrial Lobe Pumps RL Series. Performance. Nomenclature. Product Description. Section 270 Page Issue A
Section 270 Page 270.1 Issue A Performance Size Nominal Capacity Standard 2-Bushing Design Pressure High Pressure 4-Bushing Design GPM M 3 /hr PSI BAR PSI BAR RL016 105 23.8 250* 17 400* 27 RL025 160 36.3
More informationLess Loss is our Gain Water Loss Control in Los Angeles
Less Loss is our Gain Water Loss Control in Los Angeles December 5, 2017 Peter Dugan, Water Loss Task Force Project Engineer Reynold Wong, Water Loss Task Force Project Engineer LADWP California s Largest
More informationCITY OF BARTLETT 6400 STAGE ROAD BARTLETT, TENNESSEE 38134
CITY OF BARTLETT 6400 STAGE ROAD BARTLETT, TENNESSEE 38134 A. Keith McDonald, Mayor Mark Brown, Chief Administrator Officer Dick Phebus, Finance Director Bill Yearwood, Public Works Director REQUEST FOR
More informationHUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:
Performance RPM: 1550 Discharge: 1" Solids: 1/8" Wholesale Products Page: 6660-1 Section: Performance The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower.
More informationCombination Air Valves - Stainless Steel/ Sanitary Sewer/ For 2 Thru 12 Mains
D 1 D 1.1 D 1.2 D 1.3 D 1.4 D 1.5 D 2 D 3 D 3.1 D 3.2 D 4 D 4.1 D 5 D 6 D 7 D 8 Valves- Resilient Seat/ 2 (FIPT X FIPT) Valves - AWWA C509/ Resilient Seat/ 2 Thru 12 (MJ X MJ) Tap Valves - AWWA C509/ Resilient
More information1. Required Minimum Flow:
SECTION 6 6. 6.01 General The City of Castle Rock Water System Minimum Standards and Specifications are minimum base level performance, design, and construction standards used to maintain uniformity of
More informationAll definitions are defined according to ANSI/AWWA C
SAN ANTONIO WATER SYSTEM SPECIFICATIONS FOR REDUCED-WALL, RESILIENT-SEATED GATE AND TAPPING VALVES FOR WATER SUPPLY SERVICE 4 IN. THROUGH 48 IN. ANSI/AWWA C515-01 July 2017 1. SCOPE This product specification
More informationFlanged Water Meters (non-continuous flow)
Flanged Water Meters (non-continuous flow) Features MW-F Suitable for use with domestic water Pulsed output Low head loss Specification Product Codes Meter: Cold water: Fluid temp. range: Cold 0 to 30
More informationVIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.
Page 635.1 Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps Operating 1: Series 8124A Model H8124A Nominal Flow Temp. 2 Viscosity (GPM) 15-200 (M 3 /hr.) 3.4-45 (PSI) To 200 PSI (Bar) To 14 Bar (
More informationWater & Industrial Products Catalog
Water & Industrial Products Catalog www.smith-blair.com info@smith-blair.com Phone: 800..9705 or 870.77.527 After Hours Number: 90.277.998 Fax: 800.8.792 or 870.77.52 EMERGENCY PHONE 90.277.998 In the
More informationINDEX WARRENDER...3 OVERVIEW...4 APPLICATIONS...5. WMCA (Centrifugal alloy pumps) WMCP (Centrifugal non-metallic pumps)...
Mag-Drive Pump Range Our company goal is to provide the solutions that protect our surroundings, raise the environmental awareness, and promote the growth of the community. INDEX WARRENDER...3 OVERVIEW...4
More informationPump Division HPX. API 610 Hydrocarbon Processing Pump. Bulletin PS-10-5b (E)
HPX API 61 Hydrocarbon Processing Pump Bulletin PS-1-5b (E) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other pump company in the world has the
More informationCROSBY H-SERIES DIRECT SPRING SAFETY VALVES
DIRECT SPRING SAFETY VALVES Direct spring safety valves that provide comprehensive overpressure protection for ASME Boiler and Pressure Vessel Code Section I, and Section VIII steam safety applications
More informationLRV LLR. Single Stage Horizontal. Single Stage Vertical. Two Stage Horizontal. Axially Split, General Industry Pumps.
LR Single Stage Horizontal LRV Single Stage Vertical LLR Two Stage Horizontal Axially Split, General Industry Pumps Bulletin PS-20-3b (E) Pump Supplier To The World Flowserve is the driving force in the
More informationSK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.
Performance SK75/100 RPM: 1750 Discharge: 2" Solids: 2" Wholesale Products Page: 6300-1 Section: Performance 12 40 9 30 HEAD-METERS 6 3 TOTAL HEAD IN FEET 20 10 SK75 SK100 0 0 Capacity-U.S. G.P.M. 20 40
More informationDARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES
PART 1 DESIGN DIRECTIVE 1.1 RELATED DOCUMENTS SECTION 15240 SEISMIC RESTRAINT AND VIBRATION CONTROL A. This section shall be considered as a part of each DC Standards, Part 15. 1.2 QUALITY ASSURANCE A.
More informationSECTION PIPING SPECIALS
PART 1 GENERAL 1.01 DESCRIPTION A. Work Included The Contractor shall furnish, install, and test the miscellaneous pipeline equipment, complete with accessories, and special equipment as shown on the Contract
More informationVIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.
VIKING Section 635 Page 635.1 Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps Model H8124A Operating Range1: Series 8124A Nominal (GPM) 15-500 Flow (M 3 /hr.) 3.4-114 Pressure (PSI) To 200 PSI Range
More informationSPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007
Performance SPX50 RPM: 1750 Discharge: 2" Solids: 2" SPX50H RPM: 1750 Discharge: 1 1 2" Solids: 3 4" Wholesale Products Page: 6800-1 Section: Performance The curves reflect maximum performance characteristics
More informationAvailable End Connections & Size Range
ECCENTRIC PLUG VALVES Size Range 3"-24" Water Working Hydrostatic Size Range Pressure psi Test psi 3"-12" 175 350 14"-24" 150 300 Available End Connections & Size Range Figure No. Flanged 3"-24" F-5412
More informationLRV LLR. Single-Stage Horizontal. Single-Stage Vertical. Two-Stage Horizontal. Axially Split, General Industry Pumps.
LR Single-Stage Horizontal LRV Single-Stage Vertical LLR Two-Stage Horizontal Axially Split, General Industry Pumps Bulletin PS-20-3h (E) Pump Supplier To The World Flowserve is the driving force in the
More informationAKAY INDUSTRIES PRODUCT CATALOGUE
AKAY INDUSTRIES PRODUCT CATALOGUE AKAY INDUSTRIES AT A GLANCE We are a fully integrated pump manufacturer of high quality centrifugal pumps that comply to the latest edition of international standards
More informationLRV LLR. Single-Stage Horizontal. Single-Stage Vertical. Two-Stage Horizontal. Axially Split, General Industry Pumps.
LR Single-Stage Horizontal LRV Single-Stage Vertical LLR Two-Stage Horizontal Axially Split, General Industry Pumps Bulletin PS-20-3h (E/A4) Pump Supplier To The World Flowserve is the driving force in
More information76-AR series. Stainless Steel Std. Port Ball Valve with Actuator Ready ISO Mounting Pad
76-AR series Stainless Steel Std. Port Ball Valve with Actuator Ready ISO Mounting Pad Female NPT Thread, 1/4-1 2000 CWP (psig), 1.25-2 1500 CWP (psig), 2.5-3 1000 CWP (psig). Cold Non-Shock. 250 psig
More informationRPM Rotary Gas Meters
RPM Rotary Gas Meters 02 Elster American Meter RPM Rotary Gas Meters Elster American Meter s RPM rotary meters are a positive displacement meter used to measure natural gas and other various non-corrosive
More information7000 Series Liquid Turbine Meters
BARTON 000 Series Liquid Turbine Meters Models 1xx, xx, & 3xx Barton 000 series turbines are designed for a broad range of precise liquid measurement applications. Based on 35 years of turbine manufacturing,
More informationSHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001
Performance RPM: 1550 Discharge: 1-1/2" Solids: 3/4" Wholesale Products Page: 6680-1 Section: Performance Dated: April 2002 Supersedes: January 2001 The curves reflect maximum performance characteristics
More informationWATER METER SPECIFICATIONS
City of Langley WATER METER SPECIFICATIONS Page i January 2010 CONTENTS SECTION TITLE PAGE 1. Preamble 1 2. Definitions 1 3. Services to be Metered 2 4. Location of Meters 2 5. Meter Types 2 6. Registers
More informationGoulds API ISO / API 610 VS4 Vertical Sump Pump
Goulds API 3171 ISO 13709 / API 610 VS4 Vertical Sump Pump API 3171 ISO 13709 / API 610 11 th edition, compliant VS4 sump pump Capacities to 680 m³/h (3000 GPM) Heads to 290 m (950 feet) Temperatures to
More information