Temperature Measurement Solutions. Dial Indicating Electronic Industrial RTDs Thermowells Accessories

Size: px
Start display at page:

Download "Temperature Measurement Solutions. Dial Indicating Electronic Industrial RTDs Thermowells Accessories"

Transcription

1 Temperature Measurement Solutions Dial Indicating Electronic Industrial RTDs Thermowells Accessories

2 At NOSHOK, we pride ourselves on being innovators in the industry by continually offering the latest technology and measurement solutions, and providing the best customer support in the marketplace. Established in 1967, NOSHOK was one of the fi rst companies to offer liquid fi lled pressure gauges. We also took a bold step by backing our quality gauges with an extended 3-year warranty. That unwavering standard of quality has endured for over 50 years, and as we have expanded our product offering we continue to provide industry-leading warranties. NOSHOK also leads the industry as one of the fi rst companies to offer corrosion-resistant zinc nickel plating standard on our carbon steel valves. We have the capacity to put together special requirements which are so often hard to fi nd. If you do not fi nd what you need in this catalog, chances are we can still put a solution together. NOSHOK is committed to providing excellence on every level. Thank you for choosing NOSHOK products. Jeff N. Scott President NOSHOK Corporate Headquarters Your Single Source Instrumentation Company NOSHOK is a member and actively supports: NOSHOK is an ISO 9001:2015 registered company.

3 WARRANTY INFORMATION NOSHOK s Eight Year Warranty applies to our 3" and 5" 300 Series Bimetal Thermometers. Our Three Year Warranty applies to our 800 Series Platinum Resistance Temperature Transmitters, 810 Series Compact OEM Temperature Transmitters, 820/821 and 822/823 Series Digital Temperature Indicators, 850 Series Electronic Indicating Temperature Switch/Transmitters, 900/915 Series Probe-Type Industrial RTDs, 910 Series Probe-Type Industrial RTDs with Process Connection and 920 Series RTD Transmitter. Our One Year Warranty applies to our 100, 150, 300 (2") and 350 Series Bimetal Thermometers, Vapor Actuated Remote Thermometers and Thermowells. NOSHOK guarantees all products to be free from defects in material and workmanship, to remain within catalogued accuracy specifi cations, and to operate within the catalogued performance specifi cations. These products must be operated within the catalogued environmental and application parameters. Determination of failure will be made by NOSHOK, Inc. s equipment and personnel or a certifi ed test facility specializing in this type of evaluation. T A B L E O F C O N T E N T S DIAL INDICATING THERMOMETERS Bimetal, Industrial Type: 100 SERIES Bimetal, Testing and General Purpose: 150 SERIES Bimetal, Industrial Type with External Reset: 300 SERIES Bimetal, Testing and General Purpose with External Reset: 350 SERIES Vapor Actuated Remote: 300/400/600/700/900 SERIES DIAL INDICATING THERMOMETER OPTIONS Maximum Indicating Pointer, Silicone Filled, Stem Types, Connections, Special Dials, Lenses, Certifi ed Calibration ELECTRONIC TEMPERATURE MEASUREMENT Platinum Resistance Temperature Transmitter: 800 SERIES Compact OEM Temperature Transmitter: 810 SERIES Digital Temperature Indicator: 820/821 SERIES Digital Temperature Indicator, Battery Powered 822/823 SERIES Electronic Indicating Temperature Transmitter/Switch: 850 SERIES INDUSTRIAL RESISTANCE TEMPERATURE DEVICES (RTD) Industrial RTD, Probe Type: 900 SERIES Industrial RTD, Probe Type with Connection Head: 910/915 SERIES RTD Transmitter: 920 SERIES RTD ACCESSORIES Connection Heads, Terminal Blocks THERMOWELLS Thermowells: 50/75/100 SERIES Reference Information In keeping with and for purpose of product and/or manufacturing process improvements, NOSHOK, Inc. reserves the right to make design changes without prior notice. 3

4 Dial Indicating Thermometers Bimetal, Industrial Type 100 SERIES Heavy-duty, industrial thermometer featuring a weather-resistant, tamper-proof case Single F, single C, and dual scale options available Accuracy: ±1% full scale, Grade A, ASME B /4", 2", 3" and 5" sizes - center back connection only 304 stainless steel case and bezel Standard stem lengths 2-1/2" through 42" Highly sensitive bimetallic helix coil is heat-treated for stress relief, and siliconecoated to minimize pointer vibration and maximize heat transfer and response time 360 groove around stem is a visual reference to show minimum immersion point Made in the U.S.A. APPLICATIONS Used in almost every area of manufacturing, especially suited for applications in the following areas: Industrial process Petrochemical Food & beverage processing Commercial Wastewater SERIES SPECIFICATIONS Case & bezel All 100 Series 304 stainless steel; 316 stainless steel optional Lens All 100 Series Instrument glass Pointer All 100 Series Aluminum, black fi nish Stem diameter " (3.81 mm) , , " (6.35 mm) Accuracy All 100 Series ±1% full scale, Grade A, ASME B40.3 Dial All 100 Series Anodized aluminum with large black numbers and graduations Process connection /4" NPT, 1/8" and 3/8" NPT optional /4" NPT , /2" NPT Wetted parts All 100 Series 304 stainless steel; 316 stainless steel optional Hermetic seal All 100 Series Per ASME B40.3 dustproof and leakproof Bimetal coil All 100 Series Silicone coated helix coil on ranges below 500 F for vibration dampening, maximum heat transfer and response time Over temperature All 100 Series Up to 250 F 100%; 250 F to 550 F 50%; limits 550 F to 1,000 F continuous use up to 800 F; intermittent use over 800 F 4 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

5 100 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION DIAL SIZES /4" 30 3" 20 2" 50 5" CASE TYPES 110 Back connection STEM LENGTHS /2" 090 9" " Available up to 120" 040 4" " " 060 6" " " 080 8" " " TEMPERATURE -100/100 F/C -100 F/ C to 100 F/ C 0/250 F/C 0 F/ C to 250 F/ C 50/500 F/C 50 F/ C to 500 F/ C RANGES -40/160 F/C -40 F/ C to 160 F/ C 20/240 F/C 20 F/ C to 240 F/ C 150/750 F/C 150 F/ C to 750 F/ C Dual Scale F/ C 0/140 F/C 0 F/ C to 140 F/ C 25/125 F/C 25 F/ C to 125 F/ C 200/1000 F/C 200 F/ C to 1,000 F/ C* 0/180 F/C 0 F/ C to 180 F/C 50/300 F/C 50 F/ C to 300 F/ C 0/220 F/C 0 F/ C to 220 F/ C 50/400 F/C 50 F/ C to 400 F/ C -100/100 F -100 F to 100 F 0/300 F 0 F to 300 F** 50/550 F 50 F to 550 F -50/120 F -50 F to 120 F 0/500 F 0 F to 500 F** 100/800 F 100 F to 800 F** -40/160 F -40 F to 160 F 20/240 F 20 F to 240 F 150/750 F 150 F to 750 F Single Scale F 0/140 F 0 F to 140 F 25/125 F 25 F to 125 F 200/1000 F 200 F to 1,000 F* 0/180 F 0 F to 180 F 50/250 F 50 F to 250 F 0/200 F 0 F to 200 F 50/300 F 50 F to 300 F 0/220 F 0 F to 220 F 50/400 F 50 F to 400 F 0/250 F 0 F to 250 F 50/500 F 50 F to 500 F -75/175 C -75 C to 175 C 0/50 C 0 C to 50 C 0/300 C 0 C to 300 C -70/70 C -70 C to 70 C** 0/60 C 0 C to 60 C** 0/400 C 0 C to 400 C Single Scale C -50/100 C -50 C to 100 C** 0/80 C 0 C to 80 C** 0/450 C 0 C to 450 C -50/50 C -50 C to 50 C 0/100 C 0 C to 100 C 100/400 C 100 C to 400 C -40/70 C -40 C to 70 C 0/150 C 0 C to 150 C 100/550 C 100 C to 550 C* -20/120 C -20 C to 120 C ** 0/200 C 0 C to 200 C -10/110 C -10 C to 110 C ** 0/250 C 0 C to 250 C Consult factory for additional temperature ranges OPTIONS 1/8 1/8" NPT AU 1/2" NPT Adjustable Union** SL Silicone Filled (500 F Max)*** 3/8 3/8" NPT HD Heavy-Duty Stem (0.375" Dia.)** ST Stainless Steel Tagging 6 6 mm stem diameter** LL Polycarbonate Lens TG Tempered Glass Lens 8 8 mm stem diameter** PL Acrylic Lens SS Wetted Parts** SG Safety Glass Lens** Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. Note: All 316 Stainless Steel construction (case, bezel, wetted parts) is available. Please consult factory. * Thermometers with temperature ranges 200/1000 F and 100/500 C are not recommended for continuous use above 800 F/425 C. For intermittent use only. ** Available for and models only. *** Available for , and models only. Available for model only model is only available in 2-1/2", 4", 6", 8", 12", 15" and 18" stem lengths. Not available with Silicone Filled (SL) option. EXAMPLE /140 F/C LL Dial size...3" Case type... Back connection Stem length...12" Temperature range... 0 F/ C to 140 F/ C Options...Polycarbonate Lens 5

6 Dial Indicating Thermometers Dimensions " (8.89 mm).250" (6.35 mm) Stem length as specifi ed.500" (12.70 mm) Ø 1.750" (44.45 mm) Ø 0.150" (3.81 mm) 1/4" NPT " (11.13 mm).250" (6.35 mm) Stem length as specifi ed.500" (12.70 mm) Ø 2.089" (53.06 mm) Ø 0.250" (6.35 mm) 1/4" NPT 6

7 100 SERIES DIMENSIONS " (34.93 mm) Stem length as specifi ed.625" (15.88 mm) Ø 3.187" (80.95 mm) Ø 0.250" (6.35 mm) 1/2" NPT " (43.63 mm) Stem length as specifi ed.625" (15.88 mm) Ø 5.040" ( mm) Ø 0.250" (6.35 mm) 1/2" NPT 7

8 Dial Indicating Thermometers Bimetal, Testing and General Purpose 150 SERIES Designed for general purpose testing applications, featuring a weather-resistant, tamper-proof case Pocket sized model is used by inspectors, service and maintenance personnel for spot checking Single F, single C, and dual scale options (1-3/4" and 2" models only) available Accuracy: ±1% full scale, Grade A, ASME B40.3 1", 1-3/4" and 2" sizes - center back connection only 304 stainless steel case and bezel Highly sensitive bimetallic helix coil is heat-treated for stress relief, and siliconecoated to minimize pointer vibration and maximize heat transfer and response time 360 groove around stem is a visual reference to show minimum immersion point Made in the U.S.A. APPLICATIONS Used in almost every area of manufacturing, especially suited for laboratory testing and general purpose applications in the following areas: Laboratory Food & beverage processing Concrete Asphalt OEM equipment SERIES SPECIFICATIONS Case & bezel All 150 Series 304 stainless steel Lens All 150 Series Instrument glass Pointer All 150 Series Aluminum, black fi nish Stem diameter All 150 Series.150" (3.81 mm) Accuracy All 150 Series ±1% full scale, Grade A, ASME B40.3 Dial All 150 Series Anodized aluminum with large black numbers and graduations Wetted parts All 150 Series 304 stainless steel Hermetic seal All 150 Series Per ASME B40.3 dustproof and leakproof Bimetal coil All 150 Series Silicone coated helix coil on ranges below 500 F for vibration dampening, maximum heat transfer and response time Over temperature All 150 Series Up to 250 F 100%; 250 F to 550 F 50%; limits 550 F to 1,000 F continuous use up to 800 F; intermittent use over 800 F 8 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

9 150 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION DIAL SIZES 10 1" ** /4" 20 2" CASE TYPES 150 Back connection STEM LENGTHS 050 5" " 080 8" " TEMPERATURE -100/100 F/C -100 F/ C to 100 F/ C 0/250 F/C 0 F/ C to 250 F/ C 50/550 F/C 50 F/ C to 550 F/ C RANGES -40/160 F/C -40 F/ C to 160 F/ C 20/240 F/C 20 F/ C to 240 F/ C 150/750 F/C 150 F/ C to 750 F/ C Dual Scale F/ C 0/140 F/C 0 F/ C to 140 F/ C 25/125 F/C 25 F/ C to 125 F/ C 200/1000 F/C 200 F/ C to 1,000 F/ C* (Not available on 1"model) 0/180 F/C 0 F/ C to 180 F/C 50/300 F/C 50 F/ C to 300 F/ C 0/220 F/C 0 F/ C to 220 F/ C 50/400 F/C 50 F/ C to 400 F/ C -100/100 F -100 F to 100 F 0/220 F 0 F to 220 F** 50/400 F 50 F to 400 F -50/120 F -50 F to 120 F 0/250 F 0 F to 250 F 50/500 F 50 F to 500 F** Single Scale F -40/160 F -40 F to 160 F** 20/240 F 20 F to 240 F 50/550 F 50 F to 550 F 0/140 F 0 F to 140 F 25/125 F 25 F to 125 F** 150/750 F 150 F to 750 F ** 0/180 F 0 F to 180 F 50/250 F 50 F to 250 F 200/1000 F 200 F to 1,000 F* 0/200 F 0 F to 200 F 50/300 F 50 F to 300 F -75/175 C -75 C to 175 C -10/110 C -10 C to 110 C** 0/300 C 0 C to 300 C -50/100 C -50 C to 100 C 0/50 C 0 C to 50 C** 0/400 C 0 C to 400 C Single Scale C -50/25 C -50 C to 25 C 0/100 C 0 C to 100 C 100/400 C 100 C to 400 C -50/50 C -50 C to 50 C 0/150 C 0 C to 150 C 100/550 C 100 C to 550 C* -40/70 C -40 C to 70 C** 0/200 C 0 C to 200 C -20/120C -20 C to 120 C 0/250 C 0 C to 250 C** Consult factory for additional temperature ranges OPTIONS LL Polycarbonate Lens PS Pocket Sheath*** ST Stainless Steel Tagging PL Acrylic Lens SL Silicone Filled (500 F Max) TG Tempered Glass Lens Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * Thermometers with temperature ranges 200/1000 F and 100/500 C are not recommended for continuous use above 800 F/425 C. For intermittent use only. ** 1" model available only in these ranges. *** Available for and models only, with stem lengths of 5" or 8". Available for models only. Not available on model. Also not available with Silicone Filled (SL) option. EXAMPLE /140 F/C LL Dial size...2" Case type... Back connection Stem length...8" Temperature range... 0 F/ C to 140 F/ C Options...Polycarbonate Lens 9

10 Dial Indicating Thermometers Dimensions Stem length as specifi ed.187" (4.75 mm).350" (8.89 mm) Ø (26.21 mm) Ø 0.150" (3.81 mm) " (8.89 mm) Stem length as specifi ed.187" (4.75 mm) Ø 1.750" (44.45 mm) Ø 0.150" (3.81 mm) 10

11 150 SERIES DIMENSIONS " (11.13 mm) Stem length as specifi ed.250" (6.35 mm) Ø2.089" (53.06 mm) Ø 0.150" (3.81 mm) 11

12 Dial Indicating Thermometers Bimetal, Industrial Type with External Reset 300 SERIES Highest quality thermometers available on the market Easy to calibrate with 1/16" Allen key Corrosion-resistant 304 stainless steel case and bezel provide a hermetic seal to prevent lens fogging and moisture damage Single F, single C, and dual scale options available Accuracy: ±1% full scale, Grade A, ASME B40.3 2", 3" and 5" sizes - center back and bottom connections 2" Dial Size - 1/4" NPT; 3" & 5 " Dial Sizes - 1/2" NPT Standard stem lengths 2-1/2" through 42" Minimum or maximum indicating pointers are available in 3" and 5" sizes Highly sensitive bimetallic helix coil is heat-treated for stress relief, and siliconecoated to minimize pointer vibration and maximize heat transfer and response time 360 groove around stem is a visual reference to show minimum immersion point Made in the U.S.A. APPLICATIONS Industrial process Petrochemical Food & beverage processing Commercial Wastewater SERIES SPECIFICATIONS Case & bezel All 300 Series 304 stainless steel; 316 stainless steel optional Lens All 300 Series Instrument glass Pointer All 300 Series Aluminum, black fi nish Stem diameter All 300 Series.250" (6.35 mm) Accuracy All 300 Series ±1% full scale, Grade A, ASME B40.3 Dial All 300 Series Anodized aluminum with large black numbers and graduations Process connection 2" Dial Size 1/4" NPT 3" & 5" Dial Size 1/2" NPT Wetted parts All 300 Series 304 stainless steel; 316 stainless steel optional Hermetic seal All 300 Series Per ASME B40.3 dustproof and leakproof Bimetal coil All 300 Series Silicone coated helix coil on ranges below 500 F for vibration dampening, maximum heat transfer and response time Over temperature All 300 Series Up to 250 F 100%; 250 F to 550 F 50%; limits 550 F to 1,000 F continuous use up to 800 F; intermittent use over 800 F Recalibrator All 300 Series External reset Adjustable 320 Series All stainless steel brackets with screws that angle form loosen to allow 360 rotation of head and 180 adjustment of stem position 12 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

13 300 SERIES ORDERING INFORMATION ORDERING INFORMATION DIAL SIZES 20 2" (Back connected only) 30 3" 50 5" CASE TYPES 300 Bottom connection 310 Back connection 320 Adjustable angle connection** STEM LENGTHS /2" " " 040 4" " " 060 6" " " 090 9" " Available up to 120" TEMPERATURE -100/100 F/C -100 F/ C to 100 F/ C 0/250 F/C 0 F/ C to 250 F/ C 50/500 F/C 50 F/ C to 500 F/ C RANGES -40/160 F/C -40 F/ C to 160 F/ C 20/240 F/C 20 F/ C to 240 F/ C 150/750 F/C 150 F/ C to 750 F/ C Dual Scale F/ C 0/140 F/C 0 F/ C to 140 F/ C 25/125 F/C 25 F/ C to 125 F/ C 200/1000 F/C 200 F/ C to 1,000 F/ C* 0/180 F/C 0 F/ C to 180 F/C 50/300 F/C 50 F/ C to 300 F/ C 0/220 F/C 0 F/ C to 220 F/ C 50/400 F/C 50 F/ C to 400 F/ C -100/100 F -100 F to 100 F 0/300 F 0 F to 300 F** 50/550 F 50 F to 550 F -50/120 F -50 F to 120 F 0/500 F 0 F to 500 F** 100/800 F 100 F to 800 F** -40/160 F -40 F to 160 F 20/240 F 20 F to 240 F 150/750 F 150 F to 750 F Single Scale F 0/140 F 0 F to 140 F 25/125 F 25 F to 125 F 200/1000 F 200 F to 1,000 F* 0/180 F 0 F to 180 F 50/250 F 50 F to 250 F 0/200 F 0 F to 200 F 50/300 F 50 F to 300 F 0/220 F 0 F to 220 F 50/400 F 50 F to 400 F 0/250 F 0 F to 250 F 50/500 F 50 F to 500 F -75/175 C -75 C to 175 C 0/50 C 0 C to 50 C 0/300 C 0 C to 300 C -70/70 C -70 C to 70 C** 0/60 C 0 C to 60 C** 0/400 C 0 C to 400 C Single Scale C -50/100 C -50 C to 100 C** 0/80 C 0 C to 80 C** 0/450 C 0 C to 450 C -50/50 C -50 C to 50 C 0/100 C 0 C to 100 C 100/400 C 100 C to 400 C -40/70 C -40 C to 70 C 0/150 C 0 C to 150 C 100/550 C 100 C to 550 C* -20/120 C -20 C to 120 C ** 0/200 C 0 C to 200 C -10/110 C -10 C to 110 C ** 0/250 C 0 C to 250 C Consult factory for additional temperature ranges OPTIONS 6 6 mm stem diameter ** HD Heavy-Duty Stem (0.375" Dia.)** SG Safety Glass Lens ** 8 8 mm stem diameter ** LL Polycarbonate Lens SL Silicone Filled (500 F Max) SS Connection & Stem ** MIP Min or Max Indicating Pointer*** ST Stainless Steel Tagging AU 1/2" NPT Adjustable Union** MIP2 Min and Max Indicating Pointers*** TG Tempered Glass Lens GD Glow Dial PL Acrylic Lens Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. Note: All 316 Stainless Steel construction (case, bezel, wetted parts) is available. Please consult factory. * Thermometers with temperature ranges 200/1000 F and 100/500 C are not recommended for continuous use above 800 F/425 C. For intermittent use only. ** Available for 3" and 5" dial sizes only. *** Available only on and models. Available only on and model. Includes reflective pointer and two reflective clips. Not available with Silicone Filled (SL) option. EXAMPLE /300 F/C SL Dial size...5" Case type... Back connection Stem length...12" Temperature range...50 F/ C to 300 F/C Options...Silicone Filled 13

14 Dial Indicating Thermometers Dimensions " (11.43 mm) B S.500" (12.70 mm) Ø A Ø 0.250" (6.35 mm) 1/4" NPT See page 15 for dimension chart / B S.625" (15.88 mm) Ø A Ø 0.250" (6.35 mm) 1/2" NPT See page 15 for dimension chart. 14

15 300 SERIES DIMENSIONS / / B B Ø A Ø A 2.020" MIN."** (51.31 mm) C.625" (15.88 mm).625" (15.88 mm) 1/2" NPT 1/2" NPT S S Ø 0.250" (6.35 mm) Ø 0.250" (6.35 mm) **Contact factory if specifi c dimension is required for OEM applications. Series Ø A B C S (Stem Length) ".438" mm mm As specifi ed " 1.375" mm mm As specifi ed " 1.718" mm mm As specifi ed " 1.187" 2.300" mm mm (58.42 mm) As specifi ed " 1.625" 3.000" mm mm (76.20 mm) As specifi ed " 2.430" mm mm As specifi ed " 2.660" mm mm As specifi ed 15

16 Dial Indicating Thermometers Bimetal, Testing and General Purpose with External Reset 350 SERIES Designed for general purpose testing applications, featuring a weather-resistant, tamper-proof case Pocket sized model is used by inspectors, service and maintenance personnel for spot checking A friction adjustment nut design provides easy calibration and maximum accuracy at a selected range Single F, single C, and dual scale (1-3/4" and 2" models only) options available Accuracy: ±1% full scale, Grade A, ASME B40.3 1", 1-3/8", 1-3/4", 2" and 3" sizes - center back connection only 304 stainless steel case and bezel Standard stem lengths 5 through 18" Highly sensitive bimetallic helix coil is heat-treated for stress relief, and siliconecoated to minimize pointer vibration and maximize heat transfer and response time 360 groove around stem is a visual reference to show minimum immersion point Adjustable pan clips are standard on , and models with 5" and 8" stem lengths Made in the U.S.A. APPLICATIONS Used in almost every area of manufacturing, especially suited for laboratory testing and general purpose applications in the following areas: Laboratory Food & beverage processing Concrete Asphalt OEM equipment HVAC SERIES Case & bezel All 350 Series 304 stainless steel; 316 stainless steel optional Lens Convex Polycarbonate All other 350 Series models Instrument Glass Pointer All 350 Series Aluminum, black fi nish Stem diameter All 350 Series.150" (3.81 mm) Accuracy All 350 Series ±1% full scale, Grade A, ASME B40.3 Dial All 350 Series Anodized aluminum with large black numbers and graduations Wetted parts All 350 Series 304 stainless steel; 316 stainless steel optional Hermetic seal All 350 Series Per ASME B40.3 dustproof and leakproof Bimetal coil All 350 Series Silicone coated helix coil on ranges below 500 F for vibration dampening, maximum heat transfer and response time Over temperature All 350 Series Up to 250 F 100%; 250 F to 550 F 50%; limits 550 F to 1,000 F continuous use up to 800 F; intermittent use over 800 F Recalibrator All 350 Series External reset SPECIFICATIONS 16 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

17 350 SERIES ORDERING INFORMATION ORDERING INFORMATION DIAL SIZES 10 1" ** /4" 30 3" /8" ** 20 2" CASE TYPES 350 Back connection STEM LENGTHS 050 5" ** " 080 8" ** " TEMPERATURE -100/100 F/C -100 F/ C to 100 F/ C 0/250 F/C 0 F/ C to 250 F/ C 50/550 F/C 50 F/ C to 550 F/ C RANGES -40/160 F/C -40 F/ C to 160 F/ C 20/240 F/C 20 F/ C to 240 F/ C 150/750 F/C 150 F/ C to 750 F/ C Dual Scale F/ C 0/140 F/C 0 F/ C to 140 F/ C 25/125 F/C 25 F/ C to 125 F/ C 200/1000 F/C 200 F/ C to 1,000 F/ C* (Not available on 0/180 F/C 0 F/ C to 180 F/C 50/300 F/C 50 F/ C to 300 F/ C 1"model) 0/220 F/C 0 F/ C to 220 F/ C 50/400 F/C 50 F/ C to 400 F/ C -100/100 F -100 F to 100 F 0/220 F 0 F to 220 F** 50/400 F 50 F to 400 F -50/120 F -50 F to 120 F 0/250 F 0 F to 250 F 50/500 F 50 F to 500 F** Single Scale F -40/160 F -40 F to 160 F** 20/240 F 20 F to 240 F 50/550 F 50 F to 550 F 0/140 F 0 F to 140 F 25/125 F 25 F to 125 F** 150/750 F 150 F to 750 F ** 0/180 F 0 F to 180 F 50/250 F 50 F to 250 F 200/1000 F 200 F to 1,000 F* 0/200 F 0 F to 200 F 50/300 F 50 F to 300 F -75/175 C -75 C to 175 C -10/110 C -10 C to 110 C** 0/300 C 0 C to 300 C -50/100 C -50 C to 100 C 0/50 C 0 C to 50 C** 0/400 C 0 C to 400 C Single Scale C -50/25 C -50 C to 25 C 0/100 C 0 C to 100 C 100/400 C 100 C to 400 C -50/50 C -50 C to 50 C 0/150 C 0 C to 150 C 100/550 C 100 C to 550 C* -40/70 C -40 C to 70 C** 0/200 C 0 C to 200 C -20/120C -20 C to 120 C 0/250 C 0 C to 250 C** Consult factory for additional temperature ranges OPTIONS LL Polycarbonate Lens PS Pocket Sheath*** TG Tempered Glass Lens PL Acrylic Lens ST Stainless Steel Tagging Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. Note: All 316 Stainless Steel construction (case, bezel, wetted parts) is available. Please consult factory. * Thermometers with temperature ranges 200/1000 F and 100/500 C are not recommended for continuous use above 800 F/425 C. For intermittent use only. ** and models are only available in these stem lengths and ranges. *** Available for 5" or 8" stem lengths only. Not available on model. Also not available with Silicone Filled (SL) option. EXAMPLE /300 F/C LL Dial size...3" Case type... Back connection Stem length...12" Temperature range...50 F/ C to 300 F/C Options... Polycarbonate lens 17

18 Dial Indicating Thermometers Dimensions B.102" (2.59 mm) Stem length as specifi ed ØA Ø.150" (3.81 mm) See page 19 for dimension chart /18-350/20-350/ B C S Ø A Ø.150" (3.81 mm) See page 19 for dimension chart. 18

19 350 SERIES DIMENSIONS Series Ø A B C S (Stem Length) ".350" mm 8.89 mm As specifi ed ".456" mm mm As specifi ed ".412".102" mm mm 2.59 mm As specifi ed ".438".120" mm mm 3.05 mm As specifi ed ".465".120" mm mm 3.05 mm As specifi ed Pocket Sheath is available on (shown left) and (shown right) models, with 5" or 8" stem. 19

20 Dial Indicating Thermometers Vapor Actuated Remote 300/400/ /900 SERIES Indicates media temperature using a temperature-actuated liquid in the sensing element and a highly accurate, high quality pressure gauge As the media temperature increases, the capillary fi ll fl uid vaporizes, increasing pressure in the Bourdon tube to activate the movement and pointer for proper indication Ranges available from -40 F/C to 60 F/C through 100 F/C to 350 F/C 2-1/2", 4", 4-1/2" and 6" sizes Brass, stainless steel, or phenolic case Dry or liquid fi lled Bottom, back or lower back connected Mounting options: front or rear fl ange, bezel, and u-clamp Capillary material: copper or stainless steel Bulb material & dimensions: copper or stainless steel, 2-5/8" x 3/8" through 7-5/8" x 3/8" The dial scale graduations are non-linear, therefore the highest degree of accuracy and readability is found in the upper half of the scale APPLICATIONS Power transformers Paper mills Refineries Petrochemical Oil and gas Chemical HVAC/R Food processing Pharmaceutical SERIES SPECIFICATIONS Lens 300, 600, 700 Series Acrylic 400, 900 Series Instrument glass Pointer All Aluminum, black fi nish Accuracy All ±2.0% full scale, Grade B, ASME B40.4 Dial All Aluminum, white background, dual scale, black Celsius scale and black Fahrenheit scale 20 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

21 300/400/600/700/900 SERIES ORDERING INFORMATION ORDERING INFORMATION 300 SERIES /2", brass case, bottom connection /2", brass case, back connection 400 SERIES ", all stainless, bottom connection ", all stainless, back connection ", all stainless, bottom connection ", all stainless, back connection 600 SERIES /2", phenolic case/brass bottom connection 700 SERIES /2", phenolic case/stainless bottom connection 900 SERIES ", stainless case, brass bottom connection ", stainless case, brass back connection GAUGE FILL FLUIDS 0 Dry gauge 2-40 service 1 Glycerin 3 Silicone MOUNTING OPTIONS 0 None 3 Rear fl ange 2 1 Chrome front fl ange 1 4 Bezel & u-clamp 3 2 Brass front fl ange 1 5 Stainless steel front fl ange 4 TEMPERATURE RANGES 1-40 F/ C to 60 F/ C 6 30 F/ C to 180 F/ C 2-20 F/ C to 120 F/ C 7 30 F/ C to 240 F/ C 3 0 F/ C to 250 F/ C 8 30 F/ C to 300 F/ C 4 0 F/ C to 300 F/ C 9 50 F/ C to 350 F/ C 5 20 F/ C to 220 F/ C F/ C to 350 F/ C CAPILLARY TYPES/MATERIALS 1 Plain copper 3 Plain stainless steel 2 Armored copper 4 Armored stainless steel CAPILLARY LENGTH ## Specify in feet BULB STYLES/MATERIALS 1 Plain copper 3 1/2" NPT union copper 2 Plain stainless steel 4 1/2" NPT union stainless steel BULB DIMENSIONS 1 2-5/8" x 3/8"* 6 4" x 3/8" 2 4-1/2" x 3/8" 7 9" x 3/8" 3 8" x 3/8" 8 7-5/8" x 3/8" 4 3-1/2" x 3/8" 15 6" x 1/2" 5 5 6" x 3/8" Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * Not available for gauge sizes 4" or 16' capillary 1 Only available on 300 Series 2 Not available on 600/700 Series 3 Only available on back connection case types 4 Only available on 400 & 900 Series 5 4 gauge or larger requires 6 bulb EXAMPLE Series/size/connection...2-1/2", brass case, back connection Gauge ll uid...-40º service Mounting option...chrome front fl ange Temperature range...30 F/ C to 240 F/ C Capillary type/material...armored copper Capillary length...15' Bulb style/material... 1/2" NPT union copper Bulb dimension...2-5/8" x 3/8" 21

22 Dial Indicating Thermometers Dimensions " (34 mm) 2.36" (60 mm) 2.48" (63 mm) 2.48" (63 mm) 2.13" (54 mm) 0.55" (14 mm) 0.43" (11 mm) 0.55" (14 mm) 1.34" (34 mm) Front Flange Front Flange 3.35" (85 mm) 2.95" (75 mm) 1.38" (35 mm) 0.08" (2 mm) 3.35" (85 mm) 2.95" (75 mm) 2.48" (63 mm) 0.08" (2 mm) 0.14" (3.6 mm) " (63 mm) 0.55" (14 mm) 2.09" (53 mm) 0.43" (11 mm) 0.14" (3.6 mm) " (14 mm) 1.46" (37 mm) 2.48" (63 mm) 22

23 300/400/600/700/900 SERIES DIMENSIONS Rear Flange 3.35" (85 mm) 2.95" (75 mm) 0.08" (2 mm) 1.46" (37 mm) 0.14" (3.6 mm) 2.09" (53 mm) 2.48" (63 mm) 0.55" (14 mm) Rear Flange Chrome Bezel with U-Clamp 3.35" (85 mm) 2.95" (75 mm) 0.20" (5 mm) 1.54" (39 mm) 2.36" (60 mm) 0.16" (4 mm) 2.48" (63 mm) 2.48" (63 mm) 2.68" (68 mm) 0.14" (3.5 mm) 0.55" (14 mm) 0.55" (14 mm) " (60 mm) 1.26" (32 mm) 23

24 Dial Indicating Thermometers Dimensions " (54 mm) *1.95" (49.5 mm) 3.37" (85.5 mm) *3.27" (83 mm) 3.43" (87 mm) 0.87" (22 mm) 0.70" (17.7 mm) 3.98" (101 mm) 4.65" (118 mm) 6.34" (161 mm) 0.87" (22 mm) 0.61" (15.5 mm) 1.18" (30 mm) 0.87" (22 mm) 2.13" (54 mm) 3.98" (101 mm) 1.97" (50 mm) 0.87" (22 mm) *1.95" (49.5 mm) 6.34" (161 mm) * 1,500 psi increase by 0.67" (17 mm) * 1,500 psi increase by 0.67" (17 mm) Front Flange Front Flange 5.20" (132 mm) 4.57" (116 mm) 1.81" (46 mm) 0.24" (6 mm) 7.72" (196 mm) 7.01" (178 mm) *1.63" (41.5 mm) 0.31" (8 mm) 0.19" (4.8 mm) " (87 mm) 3.97" (101 mm) 0.20" (5 mm) 0.87" (22 mm) 0.70" (17.7 mm) " (118 mm) 0.61" (15.5 mm) 6.34" (161 mm) 0.87" (22 mm) 24

25 300/400/600/700/900 SERIES DIMENSIONS Front Flange Front Flange 5.20" (132 mm) 4.57" (116 mm) 3.13" (79.5 mm) 0.24" (6 mm) 7.72" (196 mm) 7.01" (178 mm) *2.95" (75 mm) 0.31" (8 mm) 0.19" (4.8 mm) 1.18" (30 mm) 3.97" (101 mm) 0.20" (5 mm) 1.97" (50 mm) 6.34" (161 mm) " (22 mm) 2.13" (54 mm) " (22 mm) 1.95" (49.5* mm) * 1,500 psi increase by 0.67" (17 mm) Rear Flange Rear Flange 5.20" (132 mm) 4.57" (116 mm) 0.08" (2 mm) 2.20" (56 mm) 7.72" (196 mm) 7.01" (178 mm) 0.11" (3 mm) *1.91" (48.5 mm) 0.20" (5 mm) 3.43" (87 mm) 3.97" (101 mm) 0.23" (5.8 mm) 4.65" (118 mm) 6.34" (161 mm) " (17.7 mm) 0.87" (22 mm) " (15.5 mm) 0.87" (22 mm) 25

26 Dial Indicating Thermometers Dimensions Rear Flange Rear Flange 5.20" (132 mm) 4.57" (116 mm) 0.11" (3 mm) 2.07" (52.5 mm) 7.72" (196 mm) 7.01" (178 mm) 0.11" (3 mm) *1.95" (49.5 mm) 0.20" (5 mm) 1.18" (30 mm) 3.98" (101 mm) 0.23" (5.8 mm) 1.97" (50 mm) 6.34" (161 mm) " (22 mm) 3.27" (83 mm) " (22 mm) *3.27" (83 mm) /510 SS Bezel w/u-clamp SS Bezel w/u-clamp 3.21" (81.5 mm) 0.16" (4 mm) 3.07" (78 mm) 0.20" (5 mm) 3.98" (101 mm) 1.18" (30 mm) 4.21" (107 mm) 6.34" (161 mm) 1.97" (50 mm) 6.85" (174 mm) 0.87" (22 mm) 2.13" (54 mm) 0.87" (22 mm) *1.95" (49.5 mm) & " (86 mm) 5.83" (148 mm) 5.39" (137 mm) 0.43" (11 mm) 0.24" (6 mm) 3.82" (97 mm) 5.08" (129 mm) 0.87" (22 mm) 1.06" (27 mm) 1.69" (43 mm) 26

27 300/400/600/700/900 SERIES DIMENSIONS " (54 mm) 3.37" (85.5 mm) 3.43" (87 mm) 3.95" (101 mm) 0.87" (22 mm) 0.70" (17.7 mm) 1.18" (30 mm) 0.87" (22 mm) 2.13" (54 mm) 3.98" (101 mm) Front Flange 5.20" (132 mm) 4.57" (116 mm) 3.05" (77.5 mm) 0.31" (8 mm) 0.19" (4.8 mm) 1.18" (30 mm) 3.98" (101 mm) " (22 mm) 2.13" (54 mm) Rear Flange 5.20" (132 mm) 4.57" (116 mm) 0.08" (2 mm) 2.20" (56 mm) 0.14" (3.6 mm) 1.18" (30 mm) 3.98" (101 mm) " (85.5 mm) 27

28 Dial Indicating Thermometer Options ADJUSTABLE UNION CONNECTION Can be used to reposition the dial face for better viewing Also helpful when installing a thermometer where space is limited CERTIFIED CALIBRATION Available on all NOSHOK thermometers Certifi ed calibration provides the user with a serial numbered thermometer along with a calibration sheet against a primary temperature standard Traceable to the National Institute of Standards and Technology CONNECTIONS In addition to our standard 1/2" NPT connection, 1/4", 3/8" NPT and metric connections are also available If a special connection is required, please consult the factory Other options include a plain stem with an adjustable compression fi tting, or left, right or top connections GLOW DIAL (GD) Allows up close daylight and/or distant night time viewing 5" Adjustable angle or back connect Refl ective Pointer Two refl ective clips included to indicate custom minimum and maximum limits LENSES Laminated safety glass lenses are available on all 3" and 5" NOSHOK bimetal thermometers Acrylic and polycarbonate lenses are available on all NOSHOK bimetal thermometers also, however they should not be used where case temperature exceeds 300 F/150 C MINIMUM OR MAXIMUM INDICATING POINTER (MIP) The MIP allows you to view your minimum or maximum temperatures for visual clarifi cation of safe operation Available only on and models 28

29 MINIMUM AND MAXIMUM INDICATING POINTER (MIP2) The MIP2 allows you to view your minimum and maximum temperatures for visual clarifi cation of safe operation Available only on and models MOUNTING FLANGES Various sizes and types of mounting fl anges are available SILICONE FILLED All 2", 3" and 5" NOSHOK Industrial bimetal thermometers are offered in a fi lled version For applications where severe vibration may be a factor Silicone dampens and lubricates the internal mechanism thus reducing pointer oscillation and premature wear A polycarbonate lens is standard with a silicone fi lled thermometer Maximum case temperature not to exceed 300 F (150 C) SPECIAL DIALS Special ranges and dials with company names, company logos, part numbers, telephone numbers, or almost any custom layout is available STEM TYPES The 304 Series stainless steel stem is welded at the tip and case for hermetic seal 1/4" (6.35 mm) diameter is standard for lengths up to 24" (609 mm) 3/8" diameter, sharp tip options and optional 316SS wetted parts are also available 29

30 Electronic Temperature Measurement Platinum Resistance Temperature Transmitter 800 SERIES Proven 100 Ω platinum resistance sensor provides reliability, stability and unbeatable performance Economical price Standard temperature ranges from -40 F to 120 F through 0 F to 1,000 F Custom temperature ranges available from -300 F to 1,100 F (-200 C to 600 C) Wide variety of temperature ranges and connections Quick response time 316 stainless steel housing Burnout protection from 3.3 ma to 23 ma Also available with our 1800 Series attachable loop indicator CE compliant to suppress RFI, EMI, and ESD APPLICATIONS Water systems Storage tanks Industrial machinery and machine tools HVAC systems Refrigeration systems Also available with our 1800 Series attachable loop indicator. See for details. SPECIFICATIONS Output signals 4 ma to 20 ma 2-wire, 0 Vdc to 5 Vdc 3-wire 0 Vdc to 10 Vdc 3-wire, 1 Vdc to 5 Vdc 3-wire Temperature ranges Standard ranges from -40 F to 1,000 F Accuracy Measuring element Class B per EN (IEC 751) Output ±[ *ltl] C ±0.5% full scale Sensor protection Burnout protected from 3.3 ma to 23 ma Power requirement* 10 Vdc to 30 Vdc (4 ma to 20 ma, 2-wire) 10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire) 10 Vdc to 30 Vdc (1 Vdc to 5 Vdc, 3-wire) 14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire) Load limitations (VPower -10)/0.020 Amp for 4 ma to 20 ma output 5,000 Ω for 1 Vdc to 5 Vdc output 10,000 Ω for 0 Vdc to 10 Vdc output 4,500 Ω for 0.5 Vdc to 4.5 Vdc output Wetted materials 316 stainless steel Housing material 316 stainless steel Ambient temperature -40 F to 185 F (-40 C to 85 C) Storage temperature -40 F to 185 F (-40 C to 85 C) Environmental rating IP65 according to EN 60529/IEC 529 Electromagnetic rating CE compliant to EMC norm EN 61326:1997/A1:1998 RFI, EMI and ESD protection Electrical protection Reverse polarity, over-voltage and short circuit protection Weight Approximately 4 oz. * Unregulated 30 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

31 800 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION SERIES 800 TEMPERATURE -40/ F to 120 F 0/200 0 F to 200 F 0/300 0 F to 300 F 0/750 0 F to 750 F RANGES 25/ F to 125 F 20/ F to 240 F 50/ F to 300 F 0/ F/ to 1,000 F 0/140 0 F to 140 F 0/250 0 F to 250 F 50/ F to 500 F Custom ranges from -300 F through 1,100 F available on request (90 F / 50 C minimum span) ACCURACY 1 Class B + (±0.5% BFSL) OUTPUT SIGNALS 1 4 ma to 20 ma, 2-wire 3 1 Vdc to 5 Vdc, 3-wire 2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire PROCESS CONNECTIONS 21/4 NPT Male 48 1/2 NPT Male w/adjustable compression fitting 8 1/2 NPT Male ELECTRICAL CONNECTIONS 1 36 cable (connected to option 8) 14 Hirschmann connection w/iso /2 "NPT conduit 8 Hirschmann (DIN EN Form A) 25 M12 x 1 (4-pin) STEM LENGTHS " 060 6" " 040 4" 090 9" STEM DIAMETERS 3 Tapered from 6 mm - 3 mm tip 6 6 mm 8 8 mm Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. EXAMPLE / Series Temperature range...50 F to 300 F Accuracy... ±0.5% BFSL Output signal... 4 ma to 20 ma, 2-wire Process connection...1/2 NPT Male Electrical connection...hirschmann Stem length...4" Stem diameter... 6 mm 800 Series Platinum Resistance Temperature Transmitter Stem length 2.05 extension 1.65 (42 mm) 1.06 sq. (27 mm) 1.10 (28 mm) 1.85 (47 mm) 1.06 (27 mm) Adjustable stem length Hirschmann with 1/2 NPT Female ISO 4400 conduit 2.16 (55 mm) 1.06 HEX (27 mm) Adjustable compression fitting 2-WIRE WIRING * For temperature ranges above 400 F a 2.05 (50 mm) extension must be added to this dimension 3-WIRE WIRING 0.75 (19 mm) Stem length 1/2 NPT Wiring Hirschmann Cable Wiring Hirschmann Cable + Supply 1 Red + Output 2 Black + Supply 1 Red Common 2 Black + Output 3 White Stem diameter (6 mm standard) Hirschmann 1.06 (27 mm) 31

32 Electronic Temperature Measurement Compact OEM Temperature Transmitter 810 SERIES Compact size, economical price Proven 100 Ω platinum resistance sensor provides reliability, stability and unbeatable performance Standard temperature ranges from -25 F to 125 F through 0 F to 250 F 4 ma to 20 ma transmitter included 316 stainless steel housing CE compliant to suppress RFI, EMI, and ESD APPLICATIONS Mobile hydraulics Automotive Heat exchangers HVAC Transportation Refrigeration controls SPECIFICATIONS Output signal 4 ma to 20 ma, 2-wire Temperature ranges Standard ranges from -25 F to 250 F (-30 C to 120 C) Accuracy Measuring element PT100 Class B ±[ * t ] C Output ±1.5% full scale Failure signal Sensor burnout 23 ma Sensor short circuit 3.3 ma Power requirement* 10 Vdc to 36 Vdc Load limitations (Vpower - 10)/0.020 A Wetted materials 316 stainless steel Housing material 316 stainless steel Ambient temperature Maximum 185 F (85 C) Storage temperature -40 F to 185 F (-40 C to 85 C) Electromagnetic rating CE compliant to EMC norm DIN EN RFI, EMI and ESD protection Electrical protection Reverse polarity, over-voltage and short circuit protection Pressure rating 8,700 psi (600 bar) 1 * Unregulated 1 Pressure rating may vary based on the process medium, temperature and fl ow rate. 32 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

33 810 SERIES ORDERING INFORMATION DIMENSIONS SERIES 810 ORDERING INFORMATION TEMPERATURE RANGES - 25/ F to 125 F 0/140 0 F to 140 F 0/250 0 F to 250 F Custom ranges available on request (54 F minimum span) ACCURACY 1 Class B + (±1.5% BFSL) OUTPUT SIGNAL 1 4 ma to 20 ma, 2-wire PROCESS CONNECTION 21/4 NPT Male ELECTRICAL CONNECTION 25 M12 x 1 (4-pin) STEM LENGTHS 0101" 020 2" STEM DIAMETER 6 6 mm Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. EXAMPLE / Series Temperature range F to 125 F Accuracy... Class B (±1.5% BFSL) Output signal... 4 ma to 20 ma, 2-wire Process connection...1/4 NPT Male Electrical connection... M12 x 1 (4-pin) Stem length...2" Stem diameter... 6 mm 810 Series Compact OEM Temperature Transmitter.44" (11 mm).44" (11 mm) 1.69" (43 mm) Wiring - M12 x 1 (4-pin) round connector 1.69" (43 mm).75" HEX (19 mm).75" HEX (19 mm) 1/4" NPT 1/4" NPT.98" (25 mm).24" (6 mm).24" (6 mm) 1.97" (50 mm) 33

34 Electronic Temperature Measurement Digital Temperature Indicators 820/821 SERIES Large 4-digit LED display Field re-programmable with optional PC interface module and software Software includes a security feature to prevent accidental re-programming 4 ma to 20 ma programmable linearized output signal Utilizes a self-calibration feature for accurate and stable performance Optional fully programmable switch output; relay or transistor Utilizes a PT100 Ω RTD Class A element for temperature sensing M12 x 1 (5-pin) plug or 36 integral cable electrical connection IP 65 / NEMA 4 rated environmental protection All 316 stainless steel construction Easy installation with various mounting confi gurations APPLICATIONS Replacement for bimetal, liquid bulb and glass thermometers Pharmaceutical Food preparation Utilities and municipal refineries Chemical and petrochemical plants Paper mills Hydraulics Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages SPECIFICATIONS Temperature ranges Standard ranges from -325 F to 1,100 F (-200 C to 600 C) Customer rescalable with optional PC interface and software Temperature sensor RTD (PT100 DIN EN 60751, Class A) Housing material 316 stainless steel Probe material 316 stainless steel standard Maximum pressure 500 psig (on probe ) Power requirement 9-36 Vdc, polarity protected Supply effect 0.005%/V Power consumption Vdc + output current 950 mw max Vdc for PNP output 500 mw max Vdc + sourcing current for NPN output Vdc for relay output 1200 mw max. Current output 4 ma to 20 ma (3-wire confi guration) linear to temperature Max load on current output (Vsupply-9V ) / 20 ma, Ω Optional switching output Relay SPDT 240 Vac or Transistor NPN (max 100 ma source ) or Transistor PNP (max 100 ma sink) Optional switching logic N.C. or N.O. software selectable Optional switching ranges Customer programmable between -325 F to 1,100 F (-200 C to 600 C) Isolation 500 Vdc input /output (between probe and output signal ) Electrical connection M12 x 1 (5-pin) or integral cable Hysteresis 1% of range standard; customer programmable optional Accuracy 0.22% full scale; 0.1% full scale optional Open circuit detection Upscale (22 ma) or downscale (2.5 ma) current output. Error message on LED display Warm-up 30 seconds Response time 0.5 sec to 30 sec ( software selectable ) Display 4-digit LED, decimal point selectable by software Display resolution ±0.02% F.S. ±1 digit RFI effect 1% or less typical Temperature ranges Ambient -40 ºF to 176 ºF (-40 ºC to 80 ºC) Effect <0.01% FS/ ºC Storage -58 ºF to 185 ºF (-50 ºC to 85 ºC) Environmental protection NEMA 4/ IP 65 34

35 820/821 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION SERIES 820 Bottom connection 821 Back connection ACCURACY % full scale 2 0.1% full scale OUTPUT 1 4 ma to 20 ma BURNOUT U Upscale D Downscale PROCESS CONNECTIONS 0 None 8 1/2" NPT Male 2 1/4" NPT Male 48 1/2" NPT Male w/adjustable compression fitting TEMPERATURE RANGES -50/ F to 120 F -50/ F to 400 F 32/ F to 200 F 32/ F to 400 F -50/ F to 300 F 32/ F to 120 F 32/ F to 300 F ELECTRICAL CONNECTIONS 36 Integral cable 36" 48 M12 x 1 (5-pin) STEM LENGTHS " 060 6" " " 040 4" 090 9" " " STEM DIAMETERS 2 1/4" 3 3/8" 4 1/2" 6 6 mm Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. EXAMPLE D 8 32/ Series Bottom connection Accuracy % full scale Output... 4 ma to 20 ma Burnout... Downscale Process connection...1/2" NPT Male Temperature range...32 F to 200 F Electrical connection... M12 x 1 (5-pin) Stem length...9" Stem diameter... 6 mm 820 Series 821 Series M12 connector 1.799" (45.7 mm) Ø 3.000" (76.2 mm) M12 connector 1.799" (45.7 mm) 1.201" (30.5 mm) Stem length as specifi ed Ø 3.000" (76.2 mm) Stem length as specifi ed Stem diameter as specifi ed 1.201" (30.5 mm) Stem diameter as specifi ed 35

36 Electronic Temperature Measurement Digital Temperature Indicators, Battery Powered 822/823 SERIES 5 year minimum battery life Large 4-digit LCD display Utilizes a PT100 Ω RTD Class A element for temperature sensing IP 65 / NEMA 4 rated environmental protection All 316 stainless steel construction Easy installation with various mounting confi gurations APPLICATIONS Replacement for bimetal, liquid bulb and glass thermometers Pharmaceutical Food preparation Utilities and municipal refineries Chemical and petrochemical plants Paper mills Hydraulics SPECIFICATIONS Temperature ranges Standard ranges from -58 F to 392 F (-50 C to 200 C) Temperature sensor RTD (PT100 DIN EN 60751, Class A) Housing material 316 stainless steel Probe material 316 stainless steel standard Maximum pressure 500 psig (on probe ) Power requirement Lithium battery (3.6 V) Supply effect 0.005%/V Accuracy 0.22% full scale; 0.1% full scale optional Display 4-digit LCD Display resolution ±0.02% F.S. ±1 digit RFI effect 1% or less typical Temperature ranges Ambient -40 ºF to 176 ºF (-40 ºC to 80 ºC) Effect <0.01% FS/ ºC Storage -58 ºF to 185 ºF (-50 ºC to 85 ºC) Environmental protection NEMA 4/ IP 65 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

37 822/823 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION SERIES 822 Bottom connection 823 Back connection ACCURACY % full scale 2 0.1% full scale PROCESS CONNECTIONS 0 None 8 1/2" NPT Male 2 1/4" NPT Male 48 1/2" NPT Male w/adjustable compression fitting TEMPERATURE RANGE -58/ F to 392 F -50/200C -50 C to 200 C STEM LENGTHS* " 060 6" " " 040 4" 090 9" " " STEM DIAMETERS 2 1/4" 4 1/2" 8 8 mm 3 3/8" 6 6 mm Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * Consult factory for additional stem length options. EXAMPLE / Series Bottom connection Accuracy % full scale Process connection...1/2" NPT Male Temperature range F to 392 F Stem length...9" Stem diameter... 6 mm 822 Series 823 Series 1.86" (47 mm) Ø 3.10" Ø 3.19" (79 mm) (81 mm) 1.86" (47 mm) 1.75" (45 mm) Stem length as specifi ed Ø 3.10" (79 mm) Ø 3.19" (81 mm) Stem length as specifi ed Stem diameter as specifi ed 1.75" (45 mm) Stem diameter as specifi ed 37

38 Electronic Temperature Measurement Electronic Indicating Temperature Transmitter/Switch 850 SERIES Utilizes PT100 technology to provide continuous temperature monitoring, electronic temperature switching, and transmission of analog output of 4 ma to 20 ma while providing local digital indication Allows for one or two switching outputs as well as an optional analog output Two buttons on top allow simple adjustment of the temperature set points, reset points, switching functions and the measuring range of the optional analog output Wide measuring range (between -300 F and 1,100 F / -200 C and 600 C) covers the majority of temperature measuring and switching applications 1/2" NPT Male standard connection, 1/4" NPT optional A variety of stem lengths are available for maximum versatility (also available with adjustable insertion lengths) A version with tapered stem is also available for rapid response times Durable stainless steel housing and wetted parts The housing and replaceable measuring insert are screwed together to allow the exchange of the measuring insert without opening the connection to the process APPLICATIONS Mechanical engineering Heating and cooling circuits Air conditioning technology Plant construction Environmental technology Protective Cover Option Made of a thermoplastic polyurethane (TPU) material which is resistant to oil, grease and abrasion Protects the sensor while maintaining clear viewing and rotation of the display The elastic properties of the material allows set point programming without having to remove the cover Increases environmental protection to IP67 for indoor and outdoor use SPECIFICATIONS Temperature ranges Standard ranges from -300 F to 1,100 F (-200 C to 600 C) Selectable display for F or C Temperature sensor Platinum resistor (PT100 2-wire, Class B) Wetted materials 316Ti stainless steel Housing material Stainless steel Working pressure 6 mm stem diameter; 600 psi 8 mm stem diameter; 1,500 psi Power requirement* 12 Vdc to 30 Vdc Power consumption 50 ma, without load Signal output 4 ma to 20 ma scalable from % of range Switch points Number Function Individually adjustable via external control keys 1 or 2 (PNP) N.O. / N.C.; windows-and hysteresis function freely adjustable Adjustment Set point: 0.1 steps within temperature range Reset point: 0.1 steps from beginning temperature range until (set point -0.1 ) Switch rating 100 ma per switch Electrical connection M12 x 1 (4-pin) Accuracy Class B +0.25% of the temperature range Display 7 segment-led, red 4-digit, height 0.3 Temperature ranges Storage Ambient In uence -22 F to 176 F (-30 C to 80 C) -13 F to 158 F (-25 C to 70 C) ±0.006% of measuring range per F Environmental protection NEMA 4; IP65 (IEC 529) Weight Approximately 0.66 lb. * Unregulated 38 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

39 850 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION SERIES 850 SWITCH FUNCTIONS 1 2 N.O. or N.C. switch-pnp 2 1 N.O. or N.C. switch-pnp (with 4 ma to 20 ma analog output) PROCESS CONNECTIONS 21/4 NPT Male 8 1/2 NPT Male TEMPERATURE RANGES -50/ F to 400 F32/ F to 1,100 F 32/ F to 750 F -300/ F to 1,100 F ELECTRICAL CONNECTION 2 M12 x 1 (4-pin) STEM LENGTHS STEM DIAMETERS 3 Tapered from 6 mm - 3 mm tip 6 6 mm 8 8 mm OPTION PC Protective Cover Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. EXAMPLE / PC Series Switch function...2 N.O. or N.C. (PNP) Process connection...1/4" NPT Male Temperature range F to 400 F Electrical connection... M12 x 1 (4-pin) Stem length...2.5" Stem diameter... 6 mm Option...Protective Cover Additional Ordering Information Switch Set Point(s) (please specify) 1.42" (36 mm) 850 Series Upper part rotates switching output (M12 x 1) with 4 ma to 20 ma signal p-switching 4.37 (110.9 mm) 1.06" (27 mm) M12 x " (66.5 mm) 2 switching output (M12 x 1) p-switching 1.06 HEX (27 mm) 1/2 NPT standard Stem length as specifi ed (6 mm) 39

40 Industrial Resistance Temperature Devices Industrial RTD, Probe Type 900 SERIES General purpose RTD probe with PVC or PTFE lead wires Adjustable and welded fi ttings available Ideal for OEM applications PVC or PTFE jacketed lead wires are available A variety of fi tting sizes and probe diameters are available RTD PT100 Ω standard, others available 2, 3 or 4-wire circuit types Isolation to 500 Vdc Custom designs available APPLICATIONS Chemical processing Textile production Automotive Plastics processing HVAC SPECIFICATIONS Temperature ranges -50 F to 400 F (-50 C to 200 C) -50 F to 750 F (-50 C to 400 C) -330 F to 1,100 F (-200 C to 600 C) Sheath material 316 stainless steel Finish (standard) 32 micro-inches maximum Pressure rating 500 psi (34.5 bar), tube only RTD element PT F (0 C), α= IEC 751 Lead wires Stranded 22 AWG standard, PVC or PTFE insulation Self-heating 50 mw / C typical in moving water Insulation resistance Single element probes: 100 mega Ω/min. at 500 Vdc, leads to case Dual element probes: 100 mega Ω/min. at 100 Vdc, between element and leads to case Transition Sheath to wire transition max. temperature 266 F (130 C) 40 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

41 900 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION SERIES 900 TEMPERATURE RANGES -50/ F to 400 F -330/ F to 1,100 F -50/ F to 750 F ACCURACIES 1 ±0.12% (±0.3 C) at 0 C, Class B 3 ±0.04% (±0.1 C) at 0 C, Class AA 2 ±0.06% (±0.15 C) at 0 C, Class A ELEMENT TYPES C PT100 Ω at 0 C M PT1000 Ω at 0 C CIRCUIT TYPES 1 Single, 2-wire 3 Single, 4-wire 5 Dual, 3-wire 2 Single, 3-wire 4 Dual, 2-wire 6 Dual, 4-wire PROCESS CONNECTIONS 0 None 8 1/2" NPT Male 1 1/8" NPT Male 48 1/2" NPT Male w/ adjustable compression fitting 2 1/4" NPT Male ELECTRICAL CONNECTIONS 6 1/2" NPT conduit with 36" cable 48 M12 x 1 (5-pin)* 36 Integral cable 36" 49 3-pin RTD plug 37 1/2" NPT conduit with 6" flying leads 50 M12 x 1 (8-pin) STEM LENGTHS " 090 9" " 040 4" " " 060 6" " STEM DIAMETERS 1 1/8" 3 3/8" 6 6 mm 2 1/4" 4 1/2" Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * Single circuit types only EXAMPLE /750 2 C Series Temperature range F to 750 F Accuracy... ±0.06% (±0.15 C) at 0 C, Class A Element type...pt100 Ω at 0 C Circuit type... Single, 3-wire Process connection... None Electrical connection...3-pin RTD plug Stem length...6" Stem diameter... 6 mm 1/2" Conduit With Cable M12 x 1 (5-pin) Integral Cable 36" 1/2" NPT w/flying Leads RTD Plug Cable length Fitting type Cable length Fitting type Fitting type Stem diameter as specifi ed Stem length as specifi ed Stem diameter as specifi ed Stem diameter as specifi ed Stem diameter as specifi ed Stem length as specifi ed Stem diameter as specifi ed Stem length as specifi ed 41

42 Industrial Resistance Temperature Devices Industrial RTD, Probe Type with Connection Head APPROVED 910/915 SERIES Standard head-type RTD assembly A variety of head types are available Factory Mutual and Canadian Standards approved explosion proof models available Transmitter available, fi ts standard heads Probe welded to fi tting or spring loaded If used in conjunction with a thermowell, probe can be replaced in some models without possibility for leakage Process fi tting 1/2" NPT standard, others available RTD PT100 Ω standard, others available 2, 3 or 4-wire circuit types Isolation to 500 Vdc APPLICATIONS Industrial boilers Petrochemical Exhaust gas monitoring Food processing SPECIFICATIONS Temperature ranges -50 F to 400 F (-50 C to 200 C) -50 F to 750 F (-50 C to 400 C) -330 F to 1,100 F (-200 C to 600 C) Sheath material 316 stainless steel Finish (standard) 32 micro-inches maximum Pressure rating 500 psi (34.5 bar), tube only RTD element PT F (0 C), α= IEC 751 Lead wires Stranded 22 AWG standard, PVC or PTFE insulation Self-heating 50 mw / C typical in moving water Insulation resistance Single element probes: 100 mega Ω/min. at 500 Vdc, leads to case Dual element probes: 100 mega Ω/min. at 100 Vdc, between element and leads to case Environmental protection A1/A2: NEMA 4 P1 & S1/S2: NEMA 4X Transition Sheath to wire transition max. temperature 266 F (130 C) 42 Thermowells are recommended for pressure, corrosive fl uids and high velocity applications, see pages

43 910/915 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION SERIES 910 Fixed RTD 915 Spring-loaded RTD TEMPERATURE RANGES -50/ F to 400 F -330/ F to 1,100 F -50/ F to 750 F ACCURACIES 1 ±0.12% (±0.3 C) at 0 C, Class B 3 ±0.04% (±0.1 C) at 0 C, Class AA 2 ±0.06% (±0.15 C) at 0 C, Class A ELEMENT TYPES C PT100 Ω at 0 C M PT1000 Ω at 0 C CIRCUIT TYPES 1 Single, 2-wire 3 Single, 4-wire 5 Dual, 3-wire 2 Single, 3-wire 4 Dual, 2-wire 6 Dual, 4-wire 1U 4 ma to 20 ma, 2-wire, upscale burnout 3 1 Vdc to 5 Vdc, 3-wire OPTIONAL TRANSMITTER/ OUTPUT 1D 4 ma to 20 ma, 2-wire, downscale burnout 5 0 Vdc to 10 Vdc, 3-wire 2 0 Vdc to 5 Vdc, 3-wire PROCESS CONNECTIONS 0 None 8 1/2" NPT Male 2 1/4" NPT Male ELECTRICAL CONNECTIONS 23 Connection head w/ 1/2" NPT conduit 45 Connection head with 3/4" NPT conduit ELECTRICAL CONNECTION MATERIALS A1 Aluminum cast P1 PP, white S2 Stainless steel cast, explosion proof* A2 Aluminum cast, explosion proof* S1 Stainless steel cast STEM LENGTHS " 090 9" " 040 4" " " 060 6" " STEM DIAMETERS 1 1/8" 3 3/8" 6 6 mm 2 1/4" 4 1/2" Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * Factory Mutual and Canadian Standards approved explosion proof Class I, Division I, Groups B, C and D; Class II, Division I, Groups E, F and G EXAMPLE / M S Series Temperature range F to 1,100 F Accuracy... ±0.12% (±0.3 C) at 0 C, Class B Element type...pt1000 Ω at 0 C Circuit type...dual, 2-wire Process connection...1/2" NPT Male Electrical connection... Connection head w/1/2" NPT conduit Electrical connection material... Stainless steel cast Stem length...12" Stem diameter...3/8" Aluminum Cast (A1/A2) Polypropylene (P1) Stainless Steel Cast (S1/S2) NEMA 4 NEMA 4X NEMA 4X 3.6" (92 mm) 3.5" (89 mm) 3.5" (89 mm) Fitting type 4.2" (105 mm) 3.6 (91 mm) 3.6 (91 mm) Stem diameter as specifi ed Stem length as specifi ed 2.6" (65 mm) 2.0" (51 mm) 1.8" (46 mm) 43

44 Industrial Resistance Temperature Devices RTD Transmitter ORDERING INFORMATION SERIES 920 TYPE NRT Head-mounted INPUT 2 PT-100, 3-wire OUTPUTS 1 4 ma to 20 ma, 2-wire 2 0 Vdc to 5 Vdc, 3-wire 5 0 Vdc to 10 Vdc, 3-wire 36 4 ma to 20 ma, 3-wire CALIBRATED Please specify low/high TEMPERATURE RANGE UNITS OF MEASURE C Celsius F Fahrenheit OPTIONS 0 None PC* Computer Programmable Special con gurations available on request, please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. *Requires program module and software, 4 ma to 20 ma only 920 SERIES RTD TRANSMITTERS High accuracy (±0.1%) 2-wire loop-powered 4 ma to 20 ma output Linearized output to temperature Input RTD PT100 with 3-wire compensation Analog design, potentiometer adjustable Factory calibrated for fi xed range Metal housing Fits standard heads Optional model is fully fi eld re-programmable with module and PC-based = 24 Vdc, T.ambient = 25 C, Span nom. = 100 C EXAMPLE Series Type... RTD transmitter Input...PT100, 3-wire Output... 4 ma to 20 ma, 2-wire Calibrated range...0 to 200 Units of measure...fahrenheit Options... None 1.819" (46.2 mm) 1.299" (33.0 mm).75" (19.0 mm) 920 NRT 2 1 0/200 F " (29.2 mm) SPECIFICATIONS Housing material Die-cast zinc, enamel painted Housing dimensions 1.82" dia. x 1.15" H Input PT100, 3-wire, α= , DIN EN Output 4 ma to 20 ma loop powered or voltage, linear to temperature Power requirement Vdc, polarity protected Supply effect 0.02%/V, 0.001%/V with computer programmable version Zero drift ±0.01% FS/ C Span drift ±0.01% FS/ C Long term drift 0.5% FS/year Excitation current RTD 0.8 ma Sensor lead resistance RTD 500 Ω max. Accuracy 1 0.1% FS (includes effects of linearity, hysteresis and repeatability) Span/zero adjustment 20 turn potentiometer, ±10% for zero and span Maximum loop resistance Rmax. = [ ( Vsupply 9 Vdc ) / 20 ma Open circuit detection Overscale limit (27.0 ma) or underscale limit (2.2 ma) Warm up 30 seconds Temperature ranges Ambient -40 ºF to 176 ºF (-40 ºC to 80 ºC) Storage -40 ºF to 176 ºF (-40 ºC to 80 ºC) 1 Max. error on complete span. Error at calibration point 0.1 C. 44

45 RTD Accessories RTD CONNECTION HEADS Screw cover Meet NEMA requirements for indoor or outdoor use providing protection against dust, rain, splashing and hose-directed water Easy access, one-turn caps Accept standard and DIN terminal blocks and transmitters Provide greater volume for ease of fi eld wiring ORDERING INFORMATION SERIES 900 TYPE RCH RTD connection head MATERIALS A1 Aluminum, general service P1 PP (white), general service S2 Stainless steel, explosion proof* A2 Aluminum, explosion proof* S1 Stainless steel, general service INSTRUMENT CONNECTION 04 1/2" NPT Female ELECTRICAL CONNECTIONS 04 1/2" NPT Female conduit 06 3/4" NPT Female conduit Special con gurations available on request, please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * Explosion proof Class I, Division I, Groups B, C and D; Class II, Division I, Groups E, F and H EXAMPLE 900 RCH S Series Type...RTD connection head Material...Stainless steel, general service Process connection...1/2" NPT Female Electrical connection...3/4" NPT Female conduit RTD TERMINAL BLOCKS Provided with a steatite ceramic base, brass terminal pieces, and stainless steel screws Not rated for high voltage use Can be used in temperature sensor or low voltage Class 2 circuits ORDERING INFORMATION SERIES 900 TYPE RTB RTD terminal block MATERIALS B Bakelite C Ceramic CONFIGURATIONS 2 2 position 4 4 position 3 3 position 6 6 position Special con gurations available on request, please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. EXAMPLE 900 RTB C 2 Series Type... RTD terminal block Material...Ceramic Configuration...2 position 45

46 Thermowells Thermowells 50/75/100 SERIES Allows a temperature instrument to be removed and replaced without shutting down and draining the process Reduces the possibility of damage to the temperature instrument Provides protection to the operator 1/2" NPSM instrument connection, 3/4" NPT process connection standard - 1/2" NPT, 1" NPT, fl anged and sanitary options available 150 Class and 300 Class raised face fl anged thermowells available The Female thread will accept the 1/2" NPT Male thread without galling or seizing Brass, 304 stainless steel, or 316 stainless steel standard material options - other options available Standard style is stepped; available in straight and tapered Different lagging lengths are available APPLICATIONS Recommended wherever the process being measured is under pressure, corrosive, abrasive, or moving at a high velocity HVAC Petrochemical Oil and gas Process (flanged thermowells) Bore size Process connection Instrument connection Materials Presssure rating Style Maximum shank diameter SPECIFICATIONS 0.260" (6.35 mm) 1/2" NPT, 3/4" NPT, 1" NPT 1/2" NPSM 316 stainless steel, 304 stainless steel, brass 316 and 316 stainless steel: 7, F Brass: 5, F 4": Straight shank 4": Stepped shank 0.750" (19.05 mm) 46

47 50/75/100 SERIES ORDERING INFORMATION DIMENSIONS ORDERING INFORMATION PROCESS CONNECTIONS 50 1/2" NPT only 100 1" NPT or Flange Connection* 200 2" Flange Connection* 75 3/4" NPT only /2" Flange Connection* STEM LENGTHS /2"** 060 6" " 18018" 040 4"** 090 9" " " MATERIALS BRASS Brass 304SS 304 Stainless steel 316SS 316 Stainless steel Other materials available on request OPTIONS 1/4 1/4" NPT Instrument Connection PC Plug and Chain RF2 Raised Face 300 Class Flange 3/8B 3/8" Diameter Bore RF1 Raised Face 150 Class Flange Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information. * To order a Flange Connection, you must specify Option RF1 or RF2. Flange Connections available only in Stainless steel. ** Flange Connection not available. EXAMPLE SS RF1 Process connection...3/4" NPT Stem length...9" Material stainless steel Options...Raised Face Class 150 Flange Straight Shank 1-1/16 (27 mm) U 1/2" NPSM (12.7 mm) Process connection S (6.4 mm) Stepped Shank (44.45 mm) B U 1/2" NPSM (12.7 mm) Process connection S (6.4 mm) "B" Maximum Bore Size Insertion Diameter 0.260" (6.35 mm) 3/4" (19.05 mm) Straight Stepped Insertion "U" mm inch 1-5/8 2-1/2 4-1/2 7-1/2 10-1/2 13-1/2 16-1/2 22-1/2 Bore Depth "S" mm inch 2-1/ Ordering Code Flange Connection Thermowell dimensions on next page. 47

48 RF1 150 Class & RF2 300 Class Raised Face Flanges 0.25" (6.35 mm) S " (6.35 mm) 1/2" NPSM Ø 1.25" NOMINAL 2.50" (63.5 mm) U 2.25" RF1 Class 150 Flange / RF2 Class 300 Flange Insertion "U" mm inch Bore Depth "S" mm inch Ordering Code Note: NOSHOK Thermowells are provided with NPSM internal thread connections. This female connection may be used with NPT or NPSM mating threads. The NPSM thread provides a better mechanical connection without seizing or galling. 48

49 Standard Temperature Ranges / Figure Intervals F Ranges Figure Interval Div to 150 F to 120 F to 120 F to 120 F to 160 F to 100 F to 125 F to 130 F to 140 F to 200 F to 250 F to 240 F to 300 F to 400 F to 500 F to 550 F to 600 F to 750 F to 800 F to 1,000 F C Ranges Figure Interval Div. -70 to 70 C to 50 C to 50 C to 50 C to 70 C to 40 C 5 1/2-5 to 50 C 5 1/2 0 to 55 C 5 1/2-20 to 60 C 5 1/2-15 to 90 C to 120 C to 115 C to 150 C to 200 C to 260 C to 290 C to 315 C to 400 C to 425 C to 540 C 50 5 Thermowells: Pressure Rating vs. Temperature Temperature in Degrees Fahrenheit Thermowell Material 70 F 200 F 400 F 600 F 800 F 1,000 F 1,200 F Pressure Rating (Pounds Per Square Inch) Brass 5,000 4,200 1, Welded Stainless Steel Stainless Steel 7,000 6,200 5,600 5,400 5,200 4,500 1, Stainless Steel 7,000 7,000 6,400 6,200 6,100 5,100 2,500 Thermowells: Maximum Fluid Velocity vs. Insertion Length Insertion Length (Inches) Thermowell Material Fluid Type 2" 4" 8" Maximum Fluid Velocity (Feet per Second) Brass Air/Steam Water Welded Stainless Steel Air/Steam Water Stainless Steel Air/Steam Stainless Steel Water Note: The values shown in this table are based on operating temperatures of 350 F for brass and 1,000 F for stainless steel. Slightly higher velocities are possible at lower temperatures. 49

50 50 RTD Temperature vs. Resistance Table (Alpha ) C F Ohms C F Ohms C F Ohms C F Ohms C F Ohms

51 RTD Temperature vs. Resistance Table (Alpha ) C F Ohms C F Ohms C F Ohms C F Ohms C F Ohms

52 Temperature Conversions From Fahrenheit To Fahrenheit Celsius [ C] = ([ F] 32) 5/9 [ F] = [ C] 9/ Kelvin [K] = ([ F] ) 5/9 [ F] = [K] 9/ Rankine [ R] = [ F] [ F] = [ R] Delisle [ De] = (212 [ F]) 5/6 [ F] = [ De] x 6/5 Newton [ N] = ([ F] 32) 11/60 [ F] = [ N] 60/ Réaumur [ Ré] = ([ F] 32) 4/9 [ F] = [ Ré] 9/ Rømer [ Rø] = ([ F] 32) 7/ [ F] = ([ Rø] 7.5) 24/ From Celsius (Centigrade) To Celsius (Centigrade) Fahrenheit [ F] = [ C] 9/ [ C] = ([ F] 32) 5/9 Kelvin [K] = [ C] [ C] = [K] Rankine [ R] = ([ C] ) 9/5 [ C] = ([ R] ) 5/9 Delisle [ De] = (100 [ C]) 3/2 [ C] = 100 [ De] 2/3 Newton [ N] = [ C] 33/100 [ C] = [ N] 100/33 Réaumur [ Ré] = [ C] 4/5 [ C] = [ Ré] 5/4 Rømer [ Rø] = [ C] 21/ [ C] = ([ Rø] 7.5) 40/21 From Kelvin To Kelvin Celsius [ C] = [K] [K] = [ C] Fahrenheit [ F] = [K] 9/ [K] = ([ F] ) 5/9 Rankine [ R] = [K] 9/5 [K] = [ R] 5/9 Delisle [ De] = ( [K]) 3/2 [K] = [ De] 2/3 Newton [ N] = ([K] ) 33/100 [K] = [ N] 100/ Réaumur [ Ré] = ([K] ) 4/5 [K] = [ Ré] 5/ Rømer [ Rø] = ([K] ) 21/ [K] = ([ Rø] 7.5) 40/

53 Wiring Diagrams 2-Wire 3-Wire 4-Wire WHITE (1) RED RED (4) (1) RED RED (4) (1) WHITE (3) RED (3) WHITE (3) WHITE (2) Dual 2-Wire RED BLACK YELLOW WHITE (4) (1) (3) (2) Dual 3-Wire BLACK (GREY) (7) (6) BLACK (GREY) RED (4) RED (1) Dual 4-Wire BLACK (GREY) (7) (6) BLACK (GREY) RED (4) RED (1) WHITE YELLOW (3) (2) WHITE WHITE YELLOW YELLOW (3) (2) (5) (8) Thermometer Tolerance Classes per EN Tolerance Classes Resistance Tolerance at 0 C Tolerance as a Function of Absolute Value of Temperature in C Class AA ±0.04% (±0.1 C) ±[0.1 + ( * ltl)] Class A ±0.06% (±0.15 C) ±[ (0.002 * ltl)] Class B ±0.12% (±0.3 C) ±[0.3 + (0.005 * ltl)] Class C ±0.23% (±0.6 C) ±[0.6 + (0.01 * ltl)] RTD Standards Organization Standard ALPHA: Average Temperature Coefficient of Resistance ( 0 C) -1 British Standard BS 1904 : Deutsch Industrial Norm DIN : International Electrotechnical Commission IEC 751 : 1995 (Amend. 2) Scientific Apparatus Manufacturers of America SAMA RC Japanese Standard JIS C American Society for Testing & Materials ASTM E

54 NOTES 54

55 NOTES 55

56 NOTES 56

57 NOTES 57

58 NOTES 58

59 TO DOWNLOAD OR ORDER CATALOGS, VISIT NOSHOK is is committed to providing a high degree of value and continually improving processes to improve customer satisfaction by focusing on customer requirements for the design, manufacture and distribution of pressure, temperature, and force measurement instruments along with needle and manifold valves including custom manifold systems for industrial applications. 59

60 All from world class technology. Combined with real-world stamina. The highest value with the industry s best warranty. And all from a company with a 50+ year record of customer satisfaction. All from your Single Source Instrumentation Company. Corporate Headquarters 1010 West Bagley Road Berea, Ohio Ph: Fax: noshok@noshok.com Web: 60 NK12TMS-4

Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter

Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter The Instrumentation Company INTRODUCTION Established

More information

NEW Temperature Products, Cost Reductions, Improved Delivery Times!

NEW Temperature Products, Cost Reductions, Improved Delivery Times! NEW Temperature Products, Cost Reductions, Improved Delivery Times! NOSHOK is pleased to announce our re-engineered and expanded bimetal thermometer offering with cost reductions of up to 28% and significantly

More information

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials THERMOMETERS Thermometers are used to measure temperature. PIC stocks a variety of temperature measuring instruments, including bimetals, magnetic thermometers, tridicators and scale thermometers. STANDARD

More information

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS. World-Class Thermometers Since

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS. World-Class Thermometers Since TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS World-Class Thermometers Since 1916 Tel-Tru Manufacturing Company World-Class Thermometers We manufacture thermometers but we sell service, reliability,

More information

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS. Since. World-Class Thermometers.

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS. Since. World-Class Thermometers. TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS World-Class Thermometers Since 1916 www.teltru.com Tel-Tru Manufacturing Company World-Class Thermometers We manufacture thermometers - but we sell service,

More information

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS

TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS TEL-TRU MANUFACTURING COMPANY BIMETAL THERMOMETERS www.teltru.com Tel-Tru Manufacturing Company We manufacture thermometers but we sell service, reliability, product quality and performance, and our experience

More information

Direct Mounted Dial Thermometer

Direct Mounted Dial Thermometer Direct Mounted Dial Thermometer 3 1 /2" Stainless Steel Case & 4 1 /2" Cast Aluminum Case Adjustable Angle 3 1 /2", 4 1 /2" Dial Sizes ± 1 Scale Division Accuracy Stainless Steel or Cast Aluminum Case

More information

Pressure & Level Measurement Solutions

Pressure & Level Measurement Solutions Pressure & Level Measurement Solutions Pressure Gauges Dial Indicating Differential Sanitary Digital Pressure & Level Transducers & Transmitters Industrial OEM Hazardous Location Sanitary Pressure Switches

More information

Pressure & Level Measurement Solutions

Pressure & Level Measurement Solutions Pressure & Level Measurement Solutions Pressure Gauges Dial Indicating Differential Sanitary Digital Pressure & Level Transducers & Transmitters Industrial OEM Hazardous Location Sanitary Pressure Switches

More information

Pressure & Level Measurement Solutions

Pressure & Level Measurement Solutions Pressure & Level Measurement Solutions Pressure Gauges Dial Indicating Differential Sanitary Digital Pressure & Level Transducers & Transmitters Industrial OEM Hazardous Location Sanitary Pressure Switches

More information

Data Sheet Duragauge Pressure Gauge

Data Sheet Duragauge Pressure Gauge Data Sheet 1279 Duragauge Pressure Gauge TM FEATURES Custom dial printing options Micrometer adjustable pointer PLUS Performance option dampens vibration, shock and pulsation effects Pressure range from

More information

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting Ed.17.02 Design Type Case diameter in stainless steel for mounting in thermowell or for direct mounting F73 Dim 100 mm or 160 mm Accuracy Class 1,0% DIN EN 13190 Case Glass Stainless steel with bayonet

More information

Thermometer in stainless steel with vertical stem in stainless steel

Thermometer in stainless steel with vertical stem in stainless steel Ed.18.01 Design Thermometer in stainless steel with in stainless steel 1.4571 Design EN 13190 Case diameter Dim 63, 100 eller 160 mm Accuracy Class 1,0% acc.to DIN EN 13190 Type Case Glass 5500 = case

More information

New Temperature Products and Catalog

New Temperature Products and Catalog New Temperature Products and Catalog NOSHOK has expanded our temperature measurement solutions offering with the addition of several new products including: Digital temperature indicators Probe type industrial

More information

TRR. Gas or Vapour Remote Reading Thermometer

TRR. Gas or Vapour Remote Reading Thermometer TRR Gas or Vapour Remote Reading Thermometer Description & Features: Versatile, heavy duty gas or vapour thermometer for remote reading Many varieties are available from stock; special requests are built

More information

Pressure & Level Measurement Solutions

Pressure & Level Measurement Solutions Pressure & Level Measurement Solutions Pressure Gauges Dial Indicating Differential Sanitary Digital Pressure & Level Transducers & Transmitters Industrial OEM Hazardous Location Sanitary Pressure Switches

More information

Thermometer in stainless steel with adjustable stem in stainless steel. Compression fitting for direct mounting or mounting in separate thermowell

Thermometer in stainless steel with adjustable stem in stainless steel. Compression fitting for direct mounting or mounting in separate thermowell type stainless steel Ed.17.01 Design Thermometer in stainless steel in stainless steel. Compression fitting for direct mounting or mounting in separate thermowell Type Design EN 13190 Case diameter Dim

More information

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

TEK-B AR 3800E. Multivariable Pressure Transmitter.   PRESSURE. Technology Solutions Technology Solutions TEK-B AR 3800E Multivariable Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Bar 3800E is an

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

BI-METAL DIAL THERMOMETERS

BI-METAL DIAL THERMOMETERS T +6 (4) 2231 0059 F +6 (4) 2236 0236 Rm. 103-A, No. 67, T +6 (21) 5777 310 F +6 (21) 5777 319 BI-METAL DIAL THERMOMETERS 2. Case Dial 4. Connec on 5. Stem Dial 6. Stem Length 60 70 0 90 R 1 50 40 32 F

More information

AMMONIA REFRIGERATION GAUGES

AMMONIA REFRIGERATION GAUGES AMMONIA REFRIGERATION GAUGES For ammonia refrigeration applications, PIC Gauges ammonia gauges measure ammonia refrigerant pressure and corresponding temperature. 401NH3 SERIES AMMONIA-LF SERIES STANDARD

More information

Type Type 2000 Transducers. I/P & E/P Transducers

Type Type 2000 Transducers. I/P & E/P Transducers Type 2000 I/P & E/P Description Principle of Operation The Type 2000 I/P and E/P transducers utilize closed-loop pressure feedback-control for precision pressure output and minimized effects of temperature,

More information

Bimetallic Temperature Guage (TG-BM)

Bimetallic Temperature Guage (TG-BM) Bimetallic Temperature Guage (TG-BM) Precise Measurement of Temperature Guaranteed Introduction The bimetallic thermometer has a quick reacting bi-metal coil. It is manufactured from two cold-welded metal

More information

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring Level Measurement and Monitoring FN04 Liquid level sensor with continuous detection Level measurement unaffected by foam formation, conductivity, pressure or temperature Remote indication over very long

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

TNF CAPILLARY THERMOMETERS

TNF CAPILLARY THERMOMETERS TNF CAPILLARY THERMOMETERS Flow Pressure Level Temperature measurement monitoring control T2 Gas Filled Capillary Thermometer Dial Sizes: 2.5, 3, 4, 6 and 10 All Stainless Steel Construction Ranges: -40

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

High Precision Gauge Pressure Indicators

High Precision Gauge Pressure Indicators Series 300 2¾" Dial High Precision Gauge Pressure Indicators For test, laboratory, and production uses, this gauge gives accuracy in a compact size. It is sensitive, yet rugged and low in cost. Available

More information

Contact thermometer. Bimetal- or Gas actuated thermometer. Description. Features. Measuring ranges. Options. Applications

Contact thermometer. Bimetal- or Gas actuated thermometer. Description. Features. Measuring ranges. Options. Applications Force Pressure Temperature Switch Contact thermometer Bimetal- or Gas actuated thermometer - Inductive contacts - Sliding contacts - Snap action contact - Class 1 acc. to DIN EN 13190 - Optional with liquid

More information

AccuTru Sensor Technologies

AccuTru Sensor Technologies High Temperature ExL Ceramic Sheathed Thermocouples NEW TECHNOLOGIES (exclusively from AccuTru) Mi-Dry, ExL, SVS AccuTru is becoming well known in the process control community as a leading edge sensor

More information

Large selection of standard versions. Special versions at customer request. Nominal sizes: 100, 125 and 150 mm

Large selection of standard versions. Special versions at customer request. Nominal sizes: 100, 125 and 150 mm Bi-metal Thermometers all Stainless Steel Construction measuring monitoring analysing TBE Fast response times Large selection of standard versions Special versions at customer request Nominal sizes: 100,

More information

KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR

KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR Flow Pressure Level Temperature measurement monitoring control Revolutionary Microprocessor-Based Drift Stabilization NPT and 3-A Compliant Sanitary Fittings Non-Corrosive

More information

Glycerine filled Bourdon tube pressure gauges EN 837-1

Glycerine filled Bourdon tube pressure gauges EN 837-1 Application For gaseous and liquid media which are not highly viscous, do not crystallize and do not attack copper alloys. For measurement in areas with high levels of vibration and high, dynamic pressure

More information

TEK-B AR 3120B. Smart Gauge Pressure Transmitter. PRESSURE. Technology Solutions

TEK-B AR 3120B. Smart Gauge Pressure Transmitter.   PRESSURE. Technology Solutions Technology Solutions TEK-B AR 3120B Smart Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Bar 3120B Smart Gauge

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals

More information

Accu-Drive Pressure Gauges

Accu-Drive Pressure Gauges Accu-Drive DIRECT DRIVE TECHNOLOGY www.3dinstruments.com Direct Drive Concept At 3D Instruments, we believe that simple is beautiful!! Replacing the antiquated C-shaped bourdon tube in our Accu-Drive gauges

More information

TNF CAPILLARY THERMOMETERS

TNF CAPILLARY THERMOMETERS TNF CAPILLARY THERMOMETERS Flow Pressure Level Temperature measurement monitoring control T2 Gas Filled Capillary Thermometer Dial Sizes: 2.5, 3, 4, 6 and 10 All Stainless Steel Construction Ranges: -40

More information

Temperature. Our pharmaceutical technicians look to Eutech s meters for important answers.

Temperature. Our pharmaceutical technicians look to Eutech s meters for important answers. The degree of hotness or coldness of a body or environment; A measure of the average energy possessed by the molecules of a body. Our pharmaceutical technicians look to Eutech s meters for important answers.

More information

Data Sheet 8008A Commercial Pressure Gauge

Data Sheet 8008A Commercial Pressure Gauge FEATURES Meets EN837-1 and ASME B400 specifications Corrosion resistant stainless steel case Dry gauges are field fillable FlutterGuard standard on dry gauges Custom dials available Ventable fill plug

More information

INDUSTRIAL THERMOMETERS

INDUSTRIAL THERMOMETERS JJ SIKA thermometers for industry and marine sector JJ Special versions and accessories JJ SIKA thermometers for heating, air conditioning and ventilation (HVAC) INDUSTRIAL THERMOMETERS Contains products

More information

The Time & Temperature Company Company

The Time & Temperature Company Company The Time & Temperature Company Company CDN are specialists in time and temperature and offer the broadest assortment of thermometers and timers on the market, with superior product innovation, quality

More information

M7100 Pressure Transducer

M7100 Pressure Transducer Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces Medium to high

More information

INDUSTRIAL TEMPERATURE SENSORS

INDUSTRIAL TEMPERATURE SENSORS Temperature s INDUSTRIAL TEMPERATURE SENSORS Temperature s APPLIED SENSOR TECHNOLOGIES A DIVISION OF UNITED ELECTRIC CONTROLS T E M P S E N S O R - B - 0 2 Temperature s Temperature s index Subject Page

More information

Data Sheet 8008A Pressure Gauge

Data Sheet 8008A Pressure Gauge Data Sheet FEATURES Meets EN837-1 and ASME B40.100 specifications Corrosion resistant stainless steel case Dry gauges are field fillable Flutterguard standard on dry gauges Custom dials available Ventable

More information

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Plastic NEMA 4X, IP65 Enclosure

More information

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request

More information

Accu-Drive Pressure Gauges

Accu-Drive Pressure Gauges Accu-Drive Gauges DIRECT DRIVE TECHNOLOGY www.3dinstruments.com Direct Drive Concept At 3D Instruments, we believe that simple is beautiful!! Replacing the antiquated C-shaped bourdon tube in our Accu-Drive

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-4 FOOD 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR AND BIOPHARMA. Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase

More information

Rosemount 1153 Series D Alphaline Nuclear Pressure Transmitter

Rosemount 1153 Series D Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4388 Rev BA INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1974 and IEEE Std 344-1975 5.0 x 10 7 rads TID gamma radiation 7 g ZPA seismic 420 F (215.6 C) steam temperature

More information

Tuffy II Liquid Level Controls with Electric Switches

Tuffy II Liquid Level Controls with Electric Switches Tuffy II Liquid Level Controls with Electric Switches D E S C R I P T I O N The Tuffy II Liquid Level Switches are float-actuated devices designed for horizontal mounting in a tank or vessel through threaded

More information

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Outdoor/Cold Store Temperature Sensors IP67 Weatherproof Housing, 4 wire single or dual element, or 4-20mA option Weatherproof IP67 rated wall mounting

More information

Instrumentation for Water Applications

Instrumentation for Water Applications Wastewater & Water Treatment Instrumentation for Water Applications Pressure and Temperature Measurement Mechanical Pressure Measurement 2XX.34 WIKA XSEL process gauges are specifically designed and engineered

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 1 Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Authorizations Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase separation

More information

THERMOWELL ASSEMBLIES & THERMOWELLS INDEX

THERMOWELL ASSEMBLIES & THERMOWELLS INDEX THERMOWELL ASSEMBLIES & THERMOWELLS INDEX PAGE General Information & Part Numbering Examples... T2 RTD & T/C Style Thermowell Assemblies RTD'S for Thermowells (RT, RV, R4, RW, R1, R2, R5, or R8)... T3

More information

View of Arthermo Production Plant and Offices in Gessate (Milano) General Catalogue. Temperature under control

View of Arthermo Production Plant and Offices in Gessate (Milano) General Catalogue. Temperature under control View of Arthermo Production Plant and Offices in Gessate (Milano) General Catalogue 2017/1 Temperature under control The Company Arthermo has been making Measurement Instruments internationally for over

More information

Standard Bourdon tube pressure gauges EN 837-1

Standard Bourdon tube pressure gauges EN 837-1 Standard Bourdon tube pressure gauges EN 837-1 Application For gaseous and liquid media which are not highly viscous, do not crystallize and do not attack copper alloys.! When measuring gas or vapour,

More information

M7100 Pressure Transducer

M7100 Pressure Transducer Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces Medium to high

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / / 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 Harlow - Essex CM2 2DY, UK Data Sheet 6851 Page 1/7 MICROSTAT-M Particularities Electromechanical temperature

More information

Miniature I/P, E/P Transducer

Miniature I/P, E/P Transducer Miniature I/P, E/P Transducer Accurate and economical electronic pressure control The Type 550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

PRESSURE GAUGE PRICE LIST

PRESSURE GAUGE PRICE LIST Series PR - Industrial Heavy-Duty Stainless Gauge 316 Stainless Steel Tube & Socket All-Welded Construction (case to socket) Bayonet Ring with Micro-Adjustable Pointer Blowout Safety Plug (4", 6") Custom

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

GUC LNG Facility Phase IIB Expansion 6/20/14 INSTRUMENTATION SPECIFICATION. A. This Section includes instrumentation for process piping systems.

GUC LNG Facility Phase IIB Expansion 6/20/14 INSTRUMENTATION SPECIFICATION. A. This Section includes instrumentation for process piping systems. INSTRUMENTATION SPECIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Rosemount 1152 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment

More information

All-Welded System(AWS) Type M93X.D1

All-Welded System(AWS) Type M93X.D1 Diaphragm Seals Diaphragm Seals All-Welded System(AWS) Type M93X.D1 WIKA Datasheet M93X.D1 Type M93X.D1 all-welded gauge/diaphragm seal systems are a drop-in retrofit for existing gauges. This assembly

More information

Catalogue 2012/1. Temperature under control

Catalogue 2012/1. Temperature under control Catalogue 2012/1 Temperature under control Index Capillary Thermometers Section 1 Pag. 3 Bimetallic Thermometers Section 2 Pag. 9 Thermostats Section 3 Pag. 19 Digital Instruments Section 4 Pag. 24 Heating

More information

Industrial Thermometer

Industrial Thermometer Industrial Thermometer Quality by Tradition Since 1901 Dr. Siebert & Kühn have produced precision measuring and control instruments. To solve your measuring problems, modern facilities and an up-to-date

More information

Resistance Temperature Detectors (RTD)

Resistance Temperature Detectors (RTD) Resistance Temperature Detectors (RTD) Style H Connection Head Assembly Connection Head Option A - Aluminum Tip Style F - Flat Tip Head Fitting Option G - ½ NPT Hex Nipple Head Fitting Option A - Fixed

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Tuffy II Liquid Level Controls with Electric Switches

Tuffy II Liquid Level Controls with Electric Switches Tuffy II Liquid Level Controls with Electric Switches D E S C R I P T I O N The Tuffy II Liquid Level Switches are float-actuated devices designed for horizontal mounting in a tank or vessel through threaded

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

TemperaTure SenSor experts

TemperaTure SenSor experts www.thermistor.com TemperaTure SenSor experts Surface probes CuSTom SoluTionS: With QTI Probes you have the flexiblilty of applying a variety of sensor options with the housing of your choice. THerMIsTor

More information

SURFACE TEMPERATURE SENSORS

SURFACE TEMPERATURE SENSORS SURFACE TEMPERATURE SENSORS These sensors are thermocouples and resistance thermometers for surface temperature measurement of objects. C400 R400 Magnet sensors measurement and monitoring of objects such

More information

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features HLX300ExHT The HLX300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Rosemount 1154 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10

More information

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.

More information

Product Selection Guide

Product Selection Guide Product Selection Guide A Long History of Quality Gauge was founded in 1904 with 14 employees U.S. in Sellersville, Pennsylvania, outside of Philadelphia. During the 1940s, U.S. Gauge became part of AMETEK.

More information

TEMPERATURE SWITCHES AND THERMOSTATS

TEMPERATURE SWITCHES AND THERMOSTATS TEMPERATURE SWITCHES AND THERMOSTATS Our temperature switches and thermostats are ideal for applications where the end user is looking for highly accurate control across a wide range of operating temperatures.

More information

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere! JC Series High Performance Controllers...at the lowest prices anywhere! Structure Units available in standard DIN sizes (1/16, 1/8, and 1/4 DIN) NEMA 4X protective construction Black enclosure Programmable

More information

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters UTECO Temperature Probes Overview Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters About us UTECO S.A has 45 years experience in designing and manufacturing of a

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

M5100 Heavy Industrial Pressure Transducer

M5100 Heavy Industrial Pressure Transducer CE Compliance Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations DESCRIPTION The M5100 series pressure transducers from the Microfused line of MEAS, set a new price

More information

RTDs. Offered by. Phone: (203) Fax: (203) Specialists in Valves, Controls, Pneumatics, Fluid Measurement

RTDs. Offered by. Phone: (203) Fax: (203) Specialists in Valves, Controls, Pneumatics, Fluid Measurement RTDs Offered by Phone: (203) 261-6711 Fax: (203) 261-8331 www.okcautomation.com Specialists in Valves, Controls, Pneumatics, Fluid Measurement NS RTD s I- Theory of Operation n RTD s basis of operation

More information

MGO INSULATED THERMOCOUPLES INDEX

MGO INSULATED THERMOCOUPLES INDEX MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,

More information

Photoelectric Distance Sensors

Photoelectric Distance Sensors 292 Photoelectric distance sensors are used when distances to objects need to be measured or monitored or their precise position is to determined. They support positioning tasks, material fl ow controls

More information

Product overview Product overview

Product overview Product overview Product overview Product overview Control Control every move The experts for monitoring and control Pressure Temperature Level Flow Controls Barksdale The business of critical controls Market-focused.

More information

YPP6870 EXPLOSION-PROOF LOOP-POWERED PROCESS METER

YPP6870 EXPLOSION-PROOF LOOP-POWERED PROCESS METER YPP6870 EXPLOSION-PROOF LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Explosion-Proof, IP68, NEMA

More information

Degassed Cation Conductivity

Degassed Cation Conductivity Degassed Cation Conductivity DCC1000 System All conductivity measurements Calculated ph and CO2 Trend graphs Faster plant startups Degassed Cation Conductivity Measurement Reliable Cycle Chemistry Monitoring

More information

NEW CATALOG. Pressure Measurement Solution Catalog

NEW CATALOG. Pressure Measurement Solution Catalog Volume 2, Issue 3 Fall 2010 In This Issue NEW CATALOG EDITOR S NOTE NEW CATALOG PRODUCT FOCUS ATEX Approved Transducers - NEW Corrosion Resistant ZnNi Plating Now On All Valves- UPDATE APPLICATION INSIGHT

More information

Sheathed Thermocouple Sensor (120 Series)

Sheathed Thermocouple Sensor (120 Series) Applications 120 series comprise a thin-walled and felxible mineral insulated sheath cable made of stainless steel or inconel. The cable contains thermal wires embed in pressed fireproof manesium oxide.

More information

Rosemount 405 Compact Primary Element

Rosemount 405 Compact Primary Element September 2014 Rosemount DP Flow Rosemount 405 Compact Primary Element Rosemount 405 Compact Primary Element utilizes an easy to install direct mount primary element assembly. Available with Conditioning

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors Standards Certification 94/9/EC (ATEX) Directive According to European Standards EN 60079-0 EN 60079-1 EN 61241-0 EN 61241-1 Protection degeree IP66/67

More information

QUALITY INDUSTRIAL FLOWMETERS

QUALITY INDUSTRIAL FLOWMETERS QUALITY INDUSTRIAL FLOWMETERS COMPANY PROFILE Trimec Industries is an Australian owned ISO9001:2008 quality certified company specializing in the design and manufacture of a proprietary range of positive

More information

VLM10 In-line Vortex Mass Flow Meter

VLM10 In-line Vortex Mass Flow Meter VLM10 In-line Vortex Mass Flow Meter Description The VLM10 in-line vortex flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process

More information

Thermocouple Heads. MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model No.) B-9 76 (3) Model Price Material Type Number Each 48 (1 7 8)

Thermocouple Heads. MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model No.) B-9 76 (3) Model Price Material Type Number Each 48 (1 7 8) Thermocouple Heads Dimensions: mm (in) MOST POPULAR MODELS HIGHLIGHTED! Model Price Material Type Number Each 48 ( 7 8) (3 3 8) 54 (2 8) NB-0 $23 Cast Iron NB NB-2 26 NB-4 28 92 (3 5 8) NB Cast Iron NB4

More information

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com Industrial Solutions Quality is Our Driving Force interfaceforce.com The high performance you ve come to know and trust from Interface products is also available in a rugged industrial configuration. Since

More information