WATER TESTING EQUIPMENT 2016

Size: px
Start display at page:

Download "WATER TESTING EQUIPMENT 2016"

Transcription

1 WATER TESTING EQUIPMENT 206 Headquarters and Production Pool-i.d. GmbH Daimlerstr Eggenstein Germany Tel. +49 (0) Fax. +49 (0) info@water-id.com MAIN CATALOGUE WATER - ANALYSIS Water-i.d. UK Unit, Gilchrist Thomas Industrial Estate Blaenavon, Pontypool, Torfaen NP4 9RL Great Britain / UK uk@water-id.com Water-i.d. International FZC PO Box 207, SAIF Zone Airport Road, Sharjah UAE (United Arabian Emirates) Tel. +97 (0) Fax +97 (0) UAE@water-id.com Water-i.d. India Pvt. Ltd. ANM House, Plot No. A-4 Road No. 23, Wagle Industrial Area Thane (W) India Tel. +9 (0) Fax +9 (0) info@water-id.in Water-i.d. USA 77 N Union Street #98 Wilmington, DE 9805 USA Tel Fax USA@water-id.com We will be pleased to send you contact details of our distribution network around the globe. Quality reagents made in Germany

2 Quality Made in Germany High quality products and continuous quality control are not just slogans at Water-i.d they are our policy. Welcome to Water-i.d At our head office in the technology region of Karlsruhe, our laboratory team are constantly developing new formulations and improving existing products. Our Quality Control System ensures that our production and development processes are strictly monitored in accordance to international standards at our German facility. Here, the formulae are developed, tablets are pressed and blister packed to ensure maximum stability and shelf life. Our photometer PrimeLab.0 Multitest is assembled and thoroughly tested at our German Headquarters prior to delivery to our many customers. Quality reagents made in Germany Working with water means assuming responsibility. To manufacture equipment to determine water quality means to assume responsibility and to ensure that our products do everything to measure up to the task. The Water-i.d Group have been assuming responsibility for over a decade. In addition to conformance to legal requirements and standards, Water-i.d is driven to improve current processes and equipment to a higher level of technical excellence. 'Standing still means going backwards.' Water-i.d leads the way with continuous innovation to raise the standards for the future. Whether it is the 'push through' tablet reagents, the foil wrapped test strips, the 400 wavelengths covering PrimeLab with Bluetooth, software, app and cloud service, we continue to produce award winning products, most notably winning the GOLDEN WAVE as well as Piscina Barcelona Innovations award. Water-i.d SETS THE STANDARDS We are grateful to all those who share our conviction. Our customer relationships and support has enabled us to provide a quality, innovative product range for the global water analysis market. Dr. Henning Rudolf Head of Water-i.d Group, Development Department Andreas Hock (MD Water-i.d Germany) Water-i.d. Water Testing Made in Germany 2 3

3 Content Pooltester General Information Product Overview Reagents for Pooltester Page Water... All that you ever wanted to know about water. H2O Chemical compound from hydrogen and oxygen, boiling point = 00ºC, freezing point = 0ºC, highest density of g/cm3 = 4 degrees, most important solvent (Encyclopedia). More than 7% Of the earth s surface is covered by water. Covering more than roughly,384,00,000 km³ of the earth s surface, water is the most prevalent natural substance of which 97.5% is salt water in the world s oceans. Less than % is left for soil moisture content, ground water, lakes and rivers, atmosphere, and living creatures! One water molecule remains in the ocean on average for roughly 3,000 years before it evaporates again. Around 800 Litres falls yearly on m² (in Germany). Water does not disappear but has been moving in all types of circulatory systems since primeval times. Worldwide rivers transport 39,000 km³/year, which corresponds to 27,000,000,000 Litres/Day. Test Strips General Information Product Overview Comparator General Information Product Overview Reagents for Comparator Special Processes General Information Product Overview Reagents for Special Processes Balanced Water Kits General Information Product Overview Reagents for Balanced Water Kits Photometer General Information Sensor, Software and App The adapter / Technical data Parameters List Electronic Meter General Information Product Overview Bacteria Tests General Information Product Overview There is no life without water. It is a treasure indispensible to all human activity. (EU-Water-Charta Strasbourg 986) Reference Knowledgebase Terms and Conditions

4 Pooltester ph Chlorine Chlorine Dioxide Bromine Active Oxygen (O ) 2 Hydrogen Peroxide (H O ) 2 2 Alkalinity (Acid capacity) PHMB QAC Copper Zinc Pooltester / testblocks for the analysis of pool, drinking and industrial waters. Pooltesters are test devices which operate with the help of visual comparisons. The water to be tested is placed into the tester, rapidly dissolving (RAPID) reagent tablets are added, and the water changes colour. The value is determined by comparing the coloured test water with the scale on the tester. The finer the scale, the easier it is to classify the test results. Water-i.d Pooltesters distinguish themselves through their very finely graduated colour scales. The Pooltester ph/chlorine/bromine has 6 comparison colours to identify chlorine. Chlorine and bromine are detected with the aid of DPD N tablets, both using the same comparative-colour-scale. Most of the Water-i.d Pooltester come with 30 tablets per parameter. Background Pooltesters are mainly used in the wellness sector and, even if the name doesn t hint at it, they are also used for the analysis of drinking and industrial water. In many countries, for example, drinking and industrial water must be disinfected with chlorine which requires that they be subjected to consistent controls. Hotels worldwide already use the Water-i.d Pooltester for guest swimming pools, and also to determine the quality of their drinking and general waters. Water-i.d Pooltesters are even used by well-known international aid organizations to control drinking water in crisis regions. Here too, people rely on Water-i.d s quality standards. Mini-Tester The same Pooltester principles described above apply to Water-i.d Mini-Testers. The comparative scale is not as intensively graduated and Water-i.d Mini-Testers come with 20 tablets per test parameter. Distinguishing Features Perfectly coordinated and broad colour comparison scales distinguish the Water-i.d Pooltesters! Shelf-life Not only their ease of use (push-through system) distinguishes the aluminium blister packs in which the Pooltester and Mini-Tester reagent tablets are packaged. They also stand out for their long shelf-life 5 to 0 years after the date of production! Compatibility Water-i.d Pooltesters can also use tablets made by other manufacturers because technical standards define how measurements should be made for ph, chlorine, bromine, and active oxygen values with Phenol Red (ph-value), DPD N (free chlorine and/or bromine), DPD N 3 (together with DPD N = total chlorine) and DPD N 4 (active oxygen). The user can use Water-i.d reagent tablets with Pooltesters made by other manufacturers. A study by the Fresenius Institute (SGS) in March 2006 supports the fact that Water-i.d reagent tablets comply with the appropriate standards ( Water is the driving force of nature (Leonardo da Vinci) 6 7

5 Pooltester Pooltester (2 parameters) PT500 PT00 Product description N of Tablets Type of Tablets Measurement Range Unit Pooltester for the measurement 30 / 30 Phenol Red (30) ph of ph and chlorine or ph and DPD N (30) Cl (f/c) bromine values. 8 ph scale values, Br Chlorine/Bromine scale values PT200 PT400 PT500 Pooltester for the measurement of ph, chlorine or bromine, and alkalinity values. Each 8 scale values 20 / 20 / 20 Phenol Red (20) DPD N (20) Alkatest (20) ph Cl (f/c) Br Alk PT00 PT200 Pooltester for the measurement of ph and active oxygen (0 2 ) values. Each 8 scale values 30 / 30 Phenol Red (30) DPD N 4 (30) ph O Pooltester (3 parameters) PT300 Pooltester for the measurement of ph, Hydrogen Peroxide (H 2 O 2 ) and PHMB (Biguanides) values. Each 8 scale values 20 / 20 / 20 / 20 Phenol Red (20) Hyd. Peroxide HR (20) Acidifying PT (20) PHMB (20) ph PHMB 0-00 H O PT400 Pooltester for the measurement of ph and (free) Copper/ Zinc values (differential process). Each 8 Scale values, Incl. pestle to crush the tablets 20 / 20 / 20 / 20 Phenol Red (20) Copper/Zinc LR (20) EDTA (20) Dechlor (20) ph Cu PT500 PT300 PT500 Pooltester for the measurement of QAC (Quatern. Ammon. Comp.) and ph values. 8 ph scale values, 6 QAC scale values 20 / 20 / 20 Phenol Red (20) QAC HR (20) Acidifying GP (20) ph QAC Mini-Tester PTM00 Mini-Tester for the measurement of ph and Chlorine or ph and Bromine values. Each 6 scale values. 20 / 20 Phenol Red (20) DPD N (20) ph Cl (f/c) Br PTM200 Mini-Tester for the measurement of ph and Active Oxygen values (O ). Each 6 scale values 2 20 / 20 Phenol Red (20) DPD N 4 (20) ph O PTM200 PTM900 PTM900 Mini-Tester for the measurement of ph and Chlorine Dioxide values. Each 6 scale values 20/20/20 Phenol Red (20) DPD N (20) Glycine (20) ph Chlor. Diox PTM00 8 9

6 Reagents for Pooltester Quality reagents made in Germany TbsRpH... TbsRD... Type Category Measurement Range Phenol Red DPD N ph value ( ) free Chlorine / Bromine ( Cl mg/l / Br mg/l) for Pooltester PT00 PT200 PT300 PT400 PT500 PT500 PTM00 PTM200PTM900 available in boxes of 50 / 00 / 200 / 250 / 500 tablets TbsRDHC... DPD N High Calcium free Chlorine / Bromine ( Cl mg/l / Br mg/l) TbsRD3... DPD N 3 Total / combined Chlorine*** ( Cl mg/l) TbsRD4... DPD N 4 Active Oxygen (O ) 2 ( O mg/l) 2 TbsRAT... Alkatest Alkalinity (Quick Test) (0-240 mg/l) TbsRHP... Hyd.Peroxide HR Hydrogen Peroxide (H O ) 2 2 (5-50 mg/l) TbsHAFP... Acidifying PT Auxiliary Tablet to Measure H O 2 2 (ph-buffer) TbsRPB... PHMB PHMB (Biguanides) (0-00 mg/l) TbsPCZ... Copper/Zinc LR --- Copper / Zinc (Differential Meas.) ( Cu/Zn mg/l) TbsHED... EDTA --- Auxil. Tablet to Measure Copper/Zinc (Eliminating Zinc) TbsHDC... Dechlor --- Auxil. Tablet to Measure Copper/Zinc (Eliminating Chlorine) TbsRD500 TbsRQA... QAC (HR) TbsHAFG... Acidifying GP TbsHGC... Glycine Quatern. Ammonium Compounds (0-50 mg/l) Auxil. Tablet to Measure QAC Auxil. Tablet to Measure Chlorine Dioxide (Eliminating Chlorine) *** DPD N + DPD N 3 measure total Chlorine in the same water sample. The combined Chlorine is determined from the difference between free Chlorine (DPD N ) and total Chlorine (DPD N + DPD N 3). ** rapidly soluble / self disintegrating. Reagent Reagent 2 Reagent 3 Reagent 4 Tablet-Amount TbsRDpH60 Phenol Red DPD N 30 / 30 for Pooltester PT00 PT200 PT300 PT400 PT500 PT500 PTM00 PTM200PTM900 TbsRDpH60 PT00 Refill-Packs TbsRD4pH60 TbsRDpHAL60 TbsRPBO2pH80 TbsRCupH80 TbsRQAAF60 Phenol Red Phenol Red Phenol Red Phenol Red Phenol Red DPD N 4 DPD N Hyd.Peroxide HR Copper/Zinc LR QAC (HR) Alkatest PHMB EDTA Acidifying GP Acidifying PT Dechlor 30 / / 20 / / 20 / 20 / / 20 / 20 / / 20 / 20 TbsRDpHGC60 Phenol Red DPD N Glycine 20 / 20 / 20 0

7 Test Strips ph Chlorine Bromine Active Oxygen (O ) 2 Hydrogen Peroxide (H O ) 2 2 Alkalinity (Acid capacity) Salt (NaCl) Total Hardness Cyanuric Acid (Stabilizer) Quick, Simple, Optimal Test strips as well involve the measurement of water values against visual assessments of the results on a scale. In contrast to Pooltesters and Comparators, however, test strips do not work with separately added reagents (tablets) but through the chemicals already applied on the strips themselves. As a rule these are pads which have been soaked in chemicals which colour themselves upon contact with the water being measured. The resulting colour is then compared with the scale provided on the label. Distinguishing Features The EASY-DIP Test Strips are packed ten each in foil packs which guarantee that even the last strip can be used (see shelf-life). The 3 step instructions for use on the label make the product easy to use. Background Test strips for the measurement of water values are enjoying greater popularity, because they provide a simple and rapid method for quick analysis. When compared to the visual measurements of the Pooltester, there is naturally a significant disadvantage in the size of the coloured field and thus in the possibility of making an exact comparison on the colour scale. The shelf-life of the Test Strips is substantially less than that of the reagent tablets that are being used in the Pool Testers. Yet this is compensated for by the simplicity of use, the ability to obtain rapid measurements, and optimal pricing. Shelf-life Until now, the problem with using test strips has been that the bottle provided insufficient protection and the dry pouch placed inside could only guarantee at most 8 months of use. Add to this that one could assume the remaining strips would start losing their effectiveness after the bottle was opened because of the infiltration of humidity. In each can, there are 5 foil packs, that is 50 Strips. This protection guarantees a 2 /2 year shelf-life from the date of manufacture, thus ensuring use to the last Strip. Water keeps us together (unknown) 2 3

8 Test Strips Teststrips ( Parameter) EASY-Dip TSL00 Product Description 3-in- Test Strips for the measurement of ph, free Chlorine, Bromine and Alkalinity values. Each 0 of 50 Strips per can are packed in foil. N of Test Strips 50 Shelf-Life in Years 3 Measurement Range ph Cl (f) Br Alk TSL600 Teststrips (3 Parameters) TSL200 3-in- Test Strips for the measurement of ph, Active Oxygen (02 / MPS) and Alkalinity values. Each 0 of the 50 Strips per can are packed in foil ph O Alk TSL700 5-in- Test Strips for the measurement of ph, free Chlorine, Bromine Alkalinity, Total Hardness and Cyanuric Acid values. Each 0 of the 50 Strips per can are packed in foil ph Cl (f) Br Alk TH Cyan.A TSL00 TSL200 TSL300 TSL600 TSL300 Test Strips for the measurement of Salt (NaCl). Each 5 of the 20 Strips per can are packed in foil. Test Strips for the measurement of ph, Hydrogen Peroxide (H2O 2) and Alkalinity values. Each 0 of the 50 Strips per can are packed in foil ,5 3 NaCl ph H2O Alk Teststrips (5 Parameters) TSL

9 Comparator Turn and read. Active Oxygen Aluminium Ammonia Bromine Copper Copper/Zinc Cyanuric Acid Chloride Chlorine DEHA Fluoride Hyd. Peroxide Iron Manganese Molybdate Nitrate Nitrite Ozone ph Phosphate QAC Silica Sodium-Hypochlorite Sulphide Zinc Like our Pooltesters and Test Strips the Comparators rely on visual assessment. The measurement result is not detected electronically. The human eye compares the measurement colour that results from adding reagents (e.g. tablets) with a comparative scale (colour disc). The decisive difference between the Comparator and all other visual measurement processes is that this one works with a color scale in the form of a rotating disc. The colour scale is placed around the disc without interrupting the colour and shows all possible colours in the measurement scale. The water sample with reagents (0ml) is placed next to a reference sample (without reagent) inside the Comparator. The appropriate disc is inserted and turned until the colour of the sample corresponds with the colour value on the disc. Background Water-i.d comparators provide you with access to professional water analysis. While these comparators are also, like Pooltesters, visual measurement devices, the arrangement of the measured colour to the scale and the determination of the measurement value is much more precise with comparators because the measurement is compared on a rotating colour scale (colour disc). There are no measurement results between individual colour scales. Ergonomic design and high quality materials also simplify measurements. The wise find pleasure in water. (Confucius) 6 7

10 Comparator Single Components Discs Product Description Quantity Measurement-Range FD200 Disc for Active Oxygen MPS 0-5 mg/l FD3400 Disc for Aluminium mg/l FD200 Disc for Ammonia mg/l FD800 Disc for Bromine mg/l FD600 Disc for Chloride mg/l FD400 Disc for Copper mg/l FD40 Disc for Copper/Zinc LR mg/l FD402 Disc for Copper/Zinc HR mg/l FD00 Disc or Cyanuric Acid 0-80 mg/l FD00 Disc for Chlorine mg/l FD0 Disc for Chlorine HR mg/l FD0 Disc for Chlorine VHR mg/l FD900 Disc for Chlorine Dioxide mg/l FD300 Dics for DEHA mg/l FD3500 Disc for Fluoride mg/l FD300 Dics for Hyd. Peroxide 5-50 mg/l FD900 Disc for Iron LR mg/l FD950 Disc for Iron HR mg/l FD2900 Disc for Manganese mg/l FD2000 Disc for Molybdate HR 5-50 mg/l FD2200 Disc for Nitrate HR 0-00 mg/l FD700 Disc for Nitrite LR mg/l FD000 Disc for Ozone mg/l FD50 Dics for ph ph FD55 Disc for ph ph FD250 Disc for Phosphate LR mg/l FD200 Disc for Phosphate HR 0-80 mg/l FD500 Disc for QAC HR mg/l FD3000 Disc for Silica 0-00 mg/l FD3600 Disc for Sulphide mg/l FD02 Dics for Sodium-Hypochlorite 2-8 % FD40 Disc for Zinc mg/l Accessories Product Description Quantity PCP00 Comparator for Comparator-Discs Spkv5 5 Plastic Square for Comparator (0 ml) 5 Spkv0 0 Plastic Square for Comparator (0 ml) 0 Spkv50 50 Plastic Square for Comparator (0 ml) 50 Spkv00 00 Plastic Square for Comparator (0 ml) 00 Spstr Plastic Stirring Rod (3 cm) Spstr0 0 Plastic Stirring Rod (3 cm) 0 Spstr50 50 Plastic Stirring Rod (3 cm) 50 Spstr00 00 Plastic Stirring Rod (3 cm) 00 Spclb Cleaning Brush Spclb0 0 Cleaning Brush 0 Spclb50 50 Cleaning Brush 50 *** DPD N + DPD N 3 measure total Chlorine in the same water sample. The combined Chlorine is determined from the difference between free Chlorine (DPD N ) over total Chlorine (DPD N + DPD N 3). 8 9

11 Comparator Sets Sets Product Description Disc Injection 0 ml cells Stirring rod Cleaning brush PCK... Comparator-Kit, 2 plus... Black plastic case with: 2 x ml cell x stirring rod x cleaning brush x Disc and tablets... PCE... Expansion-Kit contains: plus... x 0 ml cell, x stirring rod, Discs and tablets... 00ml tube Reagents...FD200 Disc for Active Oxygen MPS 50 tabl. DPD N 4...FD3400 Disc for Aluminium 50 tabl. Aluminium N 50 tabl. Aluminium N 2...FD200 Disc for Ammonia 50 tabl. Ammonia N 50 tabl. Ammonia N 2...FD800 Disc for Bromine 50 tabl. DPD N...FD00 Disc for Chlorine 50 tabl. DPD N 50 tabl. DPD N 3...FD0 Disc for Chlorine HR 50 tabl. DPD N 50 tabl. DPD N 3...FD0 Disc for Chlorine VHR 50 tabl. Chlorine HR KI 50 tabl. Acidifying GP...FD900 Disc for Chlorine Dioxide 50 tabl. DPD N 50 tabl. Glycine...FD600 Disc for Chloride 50 tabl. Chloride N 50 tabl. Chloride N 2...FD00 Disc for Cyanuric Acid 50 tabl. CYA-Test...FD300 Disc for DEHA x 30 ml DEHA Test Solution (25 Tests) 2 x 65 ml DEHA Indicator Solution (30 Tests)...FD900 Disc for Iron LR 50 tabl. Iron LR...FD950 Disc for Iron HR 50 tabl. Iron HR...FD3500 Disc for Fluoride 65ml PL Fluoride Solution (32 Tests) 65ml PL Fluoride 2 Solution (62 Tests)...FD400 Disc for Copper 50 tabl. Copper N 50 tabl. Copper N 2...FD40 Disc for Copper/Zinc LR 50 tabl. Copper Zinc LR Product Description PCK... Comparator-Kit, 2 plus... Black plastic case with: 2 x ml cell x stirring rod x cleaning brush x disc and tablets... PCE... Expansion-Kit contains: plus... x 0 ml cell, x stirring rod, discs and tablets......fd2900 Disc for Manganese 50 tabl. Manganese LR N 50 tabl. Manganese LR N 2...FD2000 Disc for Molybdate HR 50 tabl. Molybdate HR N 50 tabl. Molybdate HR N 2...FD02 Disc for Sodium Hypochlorit 50 tabl. Chlorine HR KI 50 tabl. Acidifying GP...FD2200 Disc for Nitrate HR 40g Nitrate HR (60 Tests)...FD700 Disc for Nitrite LR 50 tabl. Nitrite LR...FD000 Disc for Ozone 50 tabl. DPD N 50 tabl. DPD N 3 50 tabl. Glycine...FD50 Disc for ph tabl. Phenol Red...FD55 Disc for ph tabl. Universal ph...fd250 Disc for Phosphate LR 00 tabl. Phosphate LR N 50 tabl. Phosphate LR N 2...FD200 Disc for Phosphate HR 00 tabl./flasche Phosphates Comparator...FD500 Disc for QAC HR 50 tabl. QAC HR 50 tabl. Acidifying GP...FD3000 Disc for Silica 20g Silica HR 60g Silica HR2 0g Silica HR3...FD3600 Disc for Sulphide 50 tabl. Sulphide N 50 tabl. Sulphide N 2...FD300 Disc for Hyd. Peroxide 50 tabl. Hyd. Perox. HR 50 tabl. Acidifying PT...FD40 Disc for Zinc 50 tabl. EDTA 50 tabl. Copper/Zinc LR Disc Injection 0 ml cells Stirring rod Cleaning brush 00ml tube Reagents...FD402 Disc for Copper/Zinc HR 50 tabl. Copper Zinc HR *** DPD N + DPD N 3 measure total Chlorine in the same water sample. The combined Chlorine is determined from the difference between free Chlorine (DPD N ) over total Chlorine (DPD N + DPD N 3). 20 2

12 available in boxes of 50 / 00 / 200 / 250 / 500 tablets and in glass bottles of 250 tablets Reagent Tablets for the Comparator Type Category Measurement-Range PCK50FD... TbsHAFG Acidifying GP Photometer Auxiliary tablet TbsHAFP Acidifying PT Photometer Hyd. Peroxide HR (5-50 mg/l) TbsHALM Aluminium N Photometer Aluminium ( mg/l) TbsPALM2 Aluminium N 2 Photometer Aluminium ( mg/l) TbsHAM Ammonia N Photometer Ammonia ( mg/l) TbsPAM Ammonia N 2 Photometer Ammonia ( mg/l) TbsHCRD Chloride N Photometer Chloride ( mg/l) TbsPCRD2 Chloride N 2 Photometer Chloride ( mg/l) TbsPCLHR Chlorine HR KI Photometer Chlorine VHR (0-300 mg/l) Sodium-Hypochlorite (2-8%) TbsPCu Copper N Photometer Copper ( mg/l) TbsPCu2 Copper N 2 Photometer Copper ( mg/l) TbsPCZLR Copper Zinc LR Photometer Copper/Zinc LR ( mg/l) Zinc ( mg/l) TbsPCZHR Copper Zinc HR Photometer Copper/Zinc HR ( mg/l) TbsPCS CYA-Test Photometer Cyanuric Acid (0-80 mg/l) TbsPD DPD N Photometer Bromine/Chlorine HR ( mg/l) Chlorine LR/Ozone ( mg/l) Chlorine-Dioxide ( mg/l) TbsPDHC DPD N High Calcium Photometer Bromine/Chlorine HR ( mg/l) Chlorine LR/Ozone ( mg/l) Chlorine-Dioxide ( mg/l) TbsPD3 DPD N 3 Photometer Chlorine LR/Ozone ( mg/l) Chlorine (HR) ( mg/l) TbsPD4 DPD N 4 Photometer Active Oxygen (MPS) (0-5 mg/l) TbsHED EDTA Photometer Zinc ( mg/l) TbsHGC Glycine Photometer Chlorine-Dioxide ( mg/l) Ozone ( mg/l) TbsRHP Hyd. Peroxide Photometer Hyd. Peroxide HR (5-50 mg/l) TbsPILR Iron LR Photometer Iron LR ( mg/l) TbsPIHR Iron HR Photometer Iron HR ( mg/l) TbsMGNSLR Manganese LR N Photometer Manganese ( mg/l) TbsPMGNS2LR Manganese LR N 2 Photometer Manganese ( mg/l) TbsHMDH Molybdate HR N Photometer Molybdate HR (5-50 mg/l) TbsPMDH2 Molybdate HR N 2 Photometer Molybdate HR (5-50 mg/l) TbsNiLR Nitrite LR Photometer Nitrite LR ( mg/l) TbsPpH Phenol Red Photometer ph ( ph) TbsHPPLR Phosphate LR N Photometer Phosphate LR ( mg/l) TbsPPPLR2 Phosphate LR N 2 Photometer Phosphate LR ( mg/l) TbsRPP Phosphates Comparator Phosphates HR (0-80 mg/l) TbsRQA QAC HR Rapid QAC (HR) (0-200 mg/l) TbsHSULFD Sulphide N Photometer Sulphide ( mg/l) TbsHSULFD2 Sulphide N 2 Photometer Sulphide ( mg/l) TbsPUPH Universal ph Photometer ph (4-0 ph) LR30Dehatest DEHA Liquid DEHA ( mg/l) LR65Dehaindic PL65Fluoride Fluoride Liquid Fluoride ( mg/l) PL65Fluoride2 DTKpow40NitrateHR Nitrate HR Powder Nitrate HR (0-00 mg/l) PLpow20SilHR Silica Powder Silica (0-00 mg/l) PLpow60SilHR2 PLpow0SilHR3

13 Special Processes Alkalinity-M Alkalinity-P Alkalinity-P (BaCl 2 ) Calcium Hardness Total Hardness Hardness yes/no Chloride Cyanuric Acid Nitrite Sulphite (LR/HR) CAS (Cleaning Acid Stregth) Permanganate Value (BOD/COD/TOC) One...two three.. The Tablet Count Process (Titration) The tablet count process forces the sample water to change colour based on the number of tablets added. For example (see image left) from yellow to red (Alkalinity-M / Acidity KS ). 4,3 The value can easily be determined on a conversion table based on the number of tablets it takes for the colour to change. The number of tablets to be added x 0.4 minus 0.2 provides the result depicted on the left, for example of mmol/l KS. 4,3 By changing the amount of fluid sampled, the measuring span can be changed. Each Special Process Kit comes with a 00 ml sampling container, a stirring rod, a cleaning brush and at least 50 reagent tablets. Opacity / Turbidity Measuring opacity is striking for its simplicity. This process is offered by Water-i.d to measure cyanuric acid. Too much cyanuric acid will limit the ability of the disinfectant (chlorine) to kill off bacteria. Determining this value is as important as determining chlorine values. The colour transition in the sample occurs by adding tablets to achieve a colour change. In measuring opacity, a syringe-like device is filled with the sampled water and a Water-i.d reagent tablet is added. The sample becomes opaque. On the bottom end of the plunger inside the device is a black dot. Next to the dot there are a series of intake openings. The plunger is now moved up and down until the black dot is no longer visible. At this stage the value can be read from the scale that is placed on the outside of the device. By diluting the sample, wide measurement ranges can be achieved. Background In this chapter, we define Special Processes as methods which are not, or are hardly, offered through classical measurement methods such as Pooltesters that is, a special process to determine the values. For example, the Water-i.d tablet count process (which causes the colour in the sampled water to abruptly change at a point when reagent tablets are continuously added). Distinguishing Features Special Process methods as described on the following pages all use high quality reagent tablets made by Water-i.d in Germany, ensuring the user to always take the same amount of reagent with each tablet. Most tablets are blistered in easy to push through aluminium bilsters, providing a long shelf life for the tablets (5 years). Water is the strongest drink. It drives mills. (unknown) 24 25

14 Special Processes Sets SVZ500* Product Description Kit to determine the Alkalinity-M value by the tablet count method. Shaker tube and tablets in a plastic case Measurement-Range Alkalinity-m (0-500 mg/l CaCO ) 3 Tablets Count Process Opacity Methode Yes / No Test 00ml Container 20ml Unit Stir. Rod Cleaning Brush Reagents Total-Alkalinity (00 tabl.) SVZ550 SVZ555 SVZ300** SVZ400** SVJ400 SVZ600 Kit to determine the Alkalinity-P value by the tablet count method. Shaker tube and tablets in a plastic case Kit to determine the Alkalinity-P value (BaCl ) by the tablet count method. 2 Shaker tube and tablets in a plastic case Kit to determine the Hardness-Calcium value by the tablet count method. Shaker tube and tablets in a plastic case Kit to determine the Hardness-Total value by the tablet count method. Shaker tube and tablets in a plastic case Kit to determine the Hardness yes/no value by the Yes/No method. Shaker tube and tablets in a plastic case Kit to determine the Chloride value by the tablet count method. Shaker tube and tablets in a plastic case Alkalinity-p ( mg/l CaCO ) 3 Alkalinity-p ( mg/l CaCO ) 3 Calcium Hardness (0-500 mg/l CaCO ) 3 Total Hardness (5-500 mg/l CaCO ) 3 Total Hardness (4 / 8 / 20 mg/l CaCO ) 3 Chloride - ( mg/l Cl ) Alkalinity-p (00 tabl.) Alkalinity-p (50 tabl.) Alk-P (BaCl ) (250 tabl./bottle) 2 Calcium Hardness (00 tabl.) Total Hardness (00 tabl.) Handness y/n (00 tabl.) Chloride (00 tabl.) SVT00 Kit to determine the Cyanuric Acid value by the opacity method. Shaker tube and tablets in a plastic case Cyanuric Acid (0-200 mg/l) Cyanuric Acid (00 tabl.) SVZ700 Kit to determine the Nitrite value by the tablet count method. Shaker tube and tablets in a plastic case Nitrite ( mg/l NaNO ) 2 Nitrite No. (00 tabl.) Nitrite No. 2 (00 tabl.) SVZ800 Kit to determine the Sulphite (LR) value by the tablet count method. Shaker tube and tablets in a plastic case Sulphite (2-50 mg/l Na SO ) 2 3 Sulphite LR No. (50 tabl.) Sulphite LR No. 2 LR (00 tabl.) SVZ850 Kit to determine the Sulphite (HR) value by the tablet count method. Shaker tube and tablets in a plastic case Sulphite (0-500 mg/l Na SO ) 2 3 Sulphite HR No. (00 tabl.) Sulphite HR No. 2 HR (00 tabl) SVZ2700 Kit to determine the Cleaning Acid Strength (CAS) concentration by the tablet count method. Shaker tube and tablets in a plastic case Clean. Ac. Strength ( %) CAS (00 tabl. bottle) SVS2800 Kit to determine the Permanganate Value as well as Sewage/Effluent BOD/COD/TOC. Shaker tubes and tablets in a plastic case. Perm. Value 0 - > 30 BOD Sewage 0 - >50 BOD Effluent 0 - > 45 COD Sewage 0 - > 300 COD Effluent 0 - > 20 TOC Sewage 0 - > 90 TOC Effluent 0 - > 60 3 Acidifying SE (200 tabl. bottle) Permanganate Value (00 tabl.) Accessories / Spares SVTdev20 Product Description 20ml turbidity unit (Cyan. Acid) SVZdev00 00ml shaker tube SPstr SPstr0 SPstr50 SPstr00 SPclb SPclb0 Spclb50 Plastic Stirring Rod (3 cm) 0 Plastic Stirring Rod (3 cm) 50 Plastic Stirring Rod (3 cm) 00 Plastic Stirring Rod (3 cm) Cleaning Brush 0 Cleaning Brush 50 Cleaning Brush * Simple conversion of the test results in dh ( German Degrees of Carbon Hardness), e (English degrees) and f (French degrees). **Simple conversion of the test results in alkaline earth ions (mmol/l), alkaline earth ions (mval/l), dh (German degrees), e (English degrees), f (French degrees). SVZdev00 SVTdev20 SPstr Spclb 26 27

15 Reagents for Special Processes available in boxes of 50 / 00 / 200 / 250 / 500 tablets and in glass bottles of 250 tablets Quality reagents made in Germany TbsRTA... Type Category Measurement-Range Alkalinity-M tabl. count Total Alkalinity (Alk-m)/ Acid Capacity (0-500 mg/l CaCO / K mmol/l ) 3 S 4,3 ** rapidly soluble / self disintegrating. for Special Process SVZ500 SVZ550 SVZ555 SVZ300 SVZ400 SVJ400 SVZ600SVT00 SVZ700 SVZ800 SVZ850 SVZ2700SVS2800 TbsRAP... Alkalinity P tabl. count Alkalinity-P ( mg/l CaCO ) 3 TbsHAPB... Alk-P (BaCl ) tabl. count Auxil. Tablet to Measure Alk-P TbsRCH... Calcium Hardness tabl. count Calcium Hardness (0-500 mg/l CaCO ) 3 TbsRTH... Total Hardness tabl. count Total Hardness (0-500 mg/l CaCO ) 3 TbsRTHJN... Hardness yes/no Yes/No Hardness (0 / 4 / 20 mg/l CaCO ) 3 TbsRCD... Chloride tabl. count Chloride - ( mg/l Cl ) TbsPCS... CYA-Test Photometer Opacity Cyanuric Acid (0-200 mg/l) TbsRNT2... Nitrite No. 2 tabl. count Nitrite ( mg/l NaNO ) 2 TbsHNT... Nitrite No. --- tabl. count Auxil. Tablet to Measure Nitrite TbsRSPIL2... Sulphite No. 2(LR) tabl. count Sulphite (2-50 mg/l Na SO ) 2 3 TbsRSPIH2.. Sulphite No. 2(HR) tabl. count Sulphite (0-500 mg/l Na SO ) 2 3 TbsHSPI... Sulphite No. --- tabl. count Auxil. Tablet to Measure Sulphite TbsRCAS... CAS tabl. count Cleaning Acid Strength ( %) TbsHASE 200B TbsRPerm Acidifying SE Permanganate Value Permanganate Value and Sewage/Effluent BOD/COD/TOC Perm. Value 0 - > 30 BOD Sewage 0 - >50 BOD Effluent 0 - > 45 COD Sewage 0 - > 300 COD Effluent 0 - > 20 TOC Sewage 0 - > 90 TOC Effluent 0 - >

16 Balanced Water Kits ph Chlorine Bromine Calcium Hardness Total Hardness Cyanuric Acid... and more on demand One kit - all in hand Balanced Water Kits are a combination of Comparators and Special Processes, such as the tablet count method and the turbidity method, covering a wide range of applications for water testing. Water-i.d offers kit combinations such as Comparator: ph, Chlorine Tablet count: Total Alkalinity, Calcium Hardness, Total Hardness Turbidity: Cyanuric Acid. Background As a combination of the Comparator method together with Special Processes, such as the tablet count and the turbidity method, Balanced Water Kits provide the advantage of all those methods in just one kit. Distinguishing Features Water-i.d offers own branding and customized kits to suite your demands. When the well s dry, we know the worth of water (Benjamin Franklin) 30 3

17 Balanced Water Kits Kits Product Description Measurement-Range Water-i.d - Comparator Comparator- Discs 0 ml Comparator Cells 00 ml Tablet Countr Tube 20 ml Turbidity Device 0 ml Syringe Stirring Rod Cleaning Brush Reagents BWK45 Balanced Water Kit. Kit to determine: ph (Comparator Method) Chlorine (free / total) (Comparator Method) Total Alkalinity (Tablet Count Method) Calcium Hardness (Tablet Count Method) In a black plastic case ph ( ) Chlorine ( ppm) Total Alkalinity (0-500 ppm CaCO 3 ) Calcium Hardness (0-500 ppm CaCO 3 ) FD50 / ph FD0 / Chlorine 4 2 Phenol Red Comp. (30 tabl.) DPD Comp. (30 tabl.) DPD 3 Comp. (30 tabl.) Alkalinity-M TC (00 tabl.) Calcium Hardness TC (00 tabl.) BWK45- Balanced Water Kit. Kit to determine: ph (Comparator Method) Chlorine (free / total) (Comparator Method) Total Alkalinity (Tablet Count Method) Calcium Hardness (Tablet Count Method) Cyanuric Acid (Turbidity Method) In a black plastic case ph ( ) Chlorine ( ppm) Total Alkalinity (0-500 ppm CaCO ) 3 Calcium Hardness (0-500 ppm CaCO ) 3 Cyanuric Acid ( ppm) FD50 / ph FD0 / Chlorine 4 2 Phenol Red Comp. (30 tabl.) DPD Comp. (30 tabl.) DPD 3 Comp. (30 tabl.) Alkalinity-M TC (00 tabl.) Calcium Hardness TC (00 tabl.) CYA-Test (00 tabl.) BWK845 Balanced Water Kit. Kit to determine: ph (Comparator Method) Bromine (total) (Comparator Method) Total Alkalinity (Tablet Count Method) Calcium Hardness (Tablet Count Method) In a black plastic case ph ( ) Bromine ( ppm) Total Alkalinity (0-500 ppm CaCO 3 ) Calcium Hardness (0-500 ppm CaCO 3 ) FD50 / ph FD800 / Bromine 4 2 Phenol Red Comp. (30 tabl.) DPD Comp. (30 tabl.) Alkalinity-M TC (00 tabl.) Calcium Hardness TC (00 tabl.) Accessories / Spares Product Description PCP00 FD50 FD0 FD800 Water-i.d Comparator Comp. Disc ph ( ph) Comp. Disc Chlorine ( mg/l) Comp. Disc Bromine ( mg/l) SPkv5 SPkv0 SPkv50 SPkv00 5 x 0ml Comparator-Cell 0 x 0ml Comparator-Cell 50 x 0ml Comparator-Cell 00 x 0ml Comparator-Cell SVZdev00 SVTdev20 SVTdev20 20ml Cyanuric Acid Turbidity Device SVZdev00 00ml Tablet Count shaker tube SPstr SPstr0 SPstr50 SPstr00 Plastic Stirring Rod (3 cm) 0 Plastic Stirring Rod (3 cm) 50 Plastic Stirring Rod (3 cm) 00 Plastic Stirring Rod (3 cm) SPclb SPclb0 SPclb50 SPinj Cleaning Brush 0 Cleaning Brush 50 Cleaning Brush 0ml Syringe SPstr SPclb BWK45 BWK

18 Reagents for Balanced Water Kits Quality reagents made in Germany TbsPpH... Type Category Measurement Range Phenol Red Photometer* Comparator ph-value ( ) for Balanced Water Kit BWK45 BWK45- BWK845 TbsPD... DPD N Photometer* Comparator free Chlorine/Bromine ( Cl ppm / Br ppm) TbsPD3... DPD N 3 Photometer* Comparator total / combined Chlorine*** ( Cl ppm) TbsRTA... Alkalinity-M * Tablet Count Total Alkalinity / Acid Capacity (0-500 ppm CaCO / K mmol/l ) 3 S 4,3 TbsRCH... Calcium Hardness * Tablet Count Calcium Hardness (0-500 ppm CaCO ) 3 TbsPCYA... CYA-Test Photometer* Turbidity Cyanuric Acid (0-200 ppm) available in boxes of 50 / 00 / 200 / 250 / 500 tablets and in glass bottles of 250 tablets ** rapidly soluble / self disintegrating. *** DPD N + DPD N 3 measure total Chlorine in the same water sample. The combined Chlorine is determined from the difference between free Chlorine (DPD N ) over total Chlorine (DPD N + DPD N 3)

19 PrimeLab Photometer PrimeLab.0 Multitest Over 00 different methods Free Software Free App Free Cloud service Photometer meets Future Photometers for electronic and highly accurate determination of water values are standard equipment in every laboratory. Similarly, mobile phones are standard equipment in our daily lives, and yet over the past few decades they have continuously adapted to technical progress. Do you still make calls today with a mobile phone of past generations from 0 or 20 years ago or do you prefer the benefits of smartphones with fast Bluetooth wireless technology, synchronisation with your PC software, apps and many other technical advantages? How about your photometer? has it kept pace with technological progress, or do you still transmit your data via a serial port, an IR interface or even not at all!? Is your data analysis restricted to predefined, parameters? Did you have a choice of which parameters you want to measure? Is the performance of your photometer limited to a few or even only one wavelength? Time for a change Sensor / optics by O O Water-i.d introduces the next generation of photometers! Data connection via Bluetooth wireless connection within seconds, similar to your smartphone in your car. A sensor by JENCOLOR with unprecedented accuracy, able to measure all parameters where colour development is visible to the human eye after adding a reagent (visible wavelength). Background When a coloured reagent is added to a water sample using a conventional photometer, light is passed through the sample, with an LED at a specific wavelength, to a sensor placed on the other side of the sample which detects how much light has passed through the water sample (transmission). From this single value on one wavelength then the water value, such as ph 7.25, is determined, using a table previously defined in the unit. Currently measurement of a comprehensive range of parameters on one device has required either installation of several light sources and sensors (set to specific wavelengths) or use of colour interference filters, to generate different wavelengths. Only one specific wavelength is measured using this technique only allowing limited parameters. The JENCOLOR MultiColor sensor has the required filters already installed on the sensor itself, and measures across several channels. This enables the PrimeLab to measure all parameters that, after addition of a reagent, show a visible colour with unprecedented precision, because the measurement is performed not around but precisely at the wavelength range of the sample measuring the colour on 400 different wavelengths simultaneously. Tests have shown that the JENCOLOR sensor, once calibrated to colour standards, achieves 98 % of the accuracy of a Spectrophotometer! And all this with only light source and only sensor! The PrimeLab is even future proof as you are able to add Parameters not installed on the device at purchase and can be conveniently installed by using PrimeLab Desktop Assistant software and the automizd update option. Software and App wich will offer you not only user based management of your measurement sources (e.g. pools) and related measurement data but also offer advice on adjusting the water values back to ranges defined by you. Software allowing you to easily upload additional parameters on your Photometer. A device that auto-calibrates itself within milliseconds at the push of a button without having to return it to the manufacturer! For detailled info visit

20 The Sensor The JENCOLOR Multiple Colour Sensor (scale ~ :20) Wavelength coverage of the JENCOLOR sensor rel. spectral sensivity Colours and their wavelengths colour purple blue green yellow orange red wavelength /nm wavelength (nm) wavelength (nm) nm nm nm nm nm nm Light Source Sensor ALL Parameters Sometimes little miracles happen when two completely different industries happen to meet and previously unforeseen synergies arise. This happened when we started development of the PrimeLab in late 200 with our development partner JENCOLOR. JENCOLOR JENCOLOR is the brand of a subsidiary of a globally renowned optics and sensor manufacturer, with its headquarters in Jena, Thuringia, Germany. The JENCOLOR Multiple Color sensors are currently used in medical equipment, pre-press and even in passenger aeroplanes for LED light control of the cabin. Technology / Colour The human eye sees colour when light falls on to the subject and light waves return to the human eye. Depending on the shape of this wave this is called wavelength we see different colours, such as red, green, etc. The wavelengths visible to the human eye-range from 380 to 780 nm. All colours recognizable by the eye are in this range. The difference When a coloured reagent is added to a water sample using a conventional photometer, light is passed through the sample, with an LED at a specific wavelength, to a sensor placed on the other side of the sample which detects how much light has passed through the water sample (transmission). From this single value on one wavelength then the water value, such as ph 7.25, is determined, using a table previously defined in the unit. Currently measurement of a comprehensive range of parameters on one device has required either installation of several light sources and sensors (set to specific wavelengths) or use of colour interference filters, to generate different wavelengths. Only one specific wavelength is measured using this technique only allowing limited parameters. The JENCOLOR MultiColor is the only one covering the complete visual wavelength of nm, which enables the PrimeLab to measure all parameters that, after addition of a reagent, show a visible colour with unprecedented precision, because not only one, but 00 data are received with one light shot. PrimeLab Desktop Assistant One of the innovations of the PrimeLab.0 is the lightning-fast wireless technology of the photometer to a Windows PC via Bluetooth. The PrimeLab.0 connects instantly and automatically after each power-up, just as you know it e.g. from your smartphone when entering your car. Each PrimeLab.0 with integrated Bluetooth -module is supplied with a Bluetooth -USB dongle with which you can add wireless connection capability to your computer if this is not already enabled. The Windows software PrimeLab Desktop Assistant is a strikingly powerful tool that allows you: Activating further measurement methods on the PrimeLab Convenient management and reporting of test results Dosage recommendations, based on your individual water treatment chemicals Updating the PrimeLab firm and software Remote control your PrimeLab Link to your PrimeLab cloud account PrimeLab App Account-data Account on device Account information First name: The PrimeLab app for Android, iphone, ipad and Windows phone lets you easily connect via Bluetooth with your PrimeLab device for complete remote control operation and even cloud services. Using PrimeLab Desktop Assistant software in combination with the PrimeLab App and our free cloud solution gives you instant access to all your test data no matter where you are. Like the PrimeLab Desktop Assistant, the App allows you to connect, remote control and update your PrimeLab device. Activating additional parameters on your PrimeLab via the app is possible as well. City: Street: The Software PrimeLab - Desktop Assistant Last name: Zip: Telephone: PrimeLab.exe Write to PrimeLab Account-No. First name Last name PLZ Stadt Straße Michael Peter Lisa Jon Cloud Price 763 Muster Measure2345 Karlsruhe Search Write to PrimeLab Daimlerstr. 20 Musterstadt Musterstr. Smith New Account AA 2BB Sampletown Samplestr. Miller 2000 Mowtown Mainstr. 5 Edit Account Test-result history Delete Account info Clear table The App 38 39

21 The Adapter Kits for Turbidity (0-000 NTU) / PTSA and Fluorescein Some test procedures, such as Turbidity (NTU), PTSA and Fluorescein, require scattered rather than direct light (LED -> sensor). To achieve this and to still use all functionality of your PrimeLab, e.g. Bluetooth connectivity, use of software, app and cloud services etc., an adapter is used which shines your water sample from above, enabling the PrimeLab to measure using scattered light (90 angle between adapter and sensor). The adapter comes in a black carrying case with professional lab-pipette, all neccessary calibration-solutions, batteries and a glass vial. Adapter and PrimeLab communicate by light. You do not even need to switch on the adapter. It will be autodetected. PrimeLab Turbidity-Adapter If turbidity should be measured in low ranges (below 20 NTU) the nephelometric method in which the LED does not shine directly through the water sample to the sensor (as in FAU), but at a 90 angle, is used. This process can be recognized by the suffix "NTU" / "FTU" or "FNU" as the measured value. More information on the nephelometric principle can be found in DIN EN ISO The PrimeLab-Turbidity-Adapter is based on secondary standards, verified against formazine (international turbidity standard) standards and uses a white-light source. PrimeLab PTSA-Adapter PTSA (,3,6,8-pyrenetetrasulfonic acid tetrasodium salt) is a stable fluorescent tracer dye that emits wavelengths between 400 and 500 nm when irradiated with UV light. It provides an excellent choice for the active on-line monitoring of cooling water treatment when a fixed known amount is added to the inhibitor being dosed. Once added to the water circulation system it is stable over time, does not react easily with other substances and is environmentally safe. The PrimeLab-PTSA-Adapter uses a UV-light source. PrimeLab-Turbidity-Adapter kit Basic equipment PrimeLab Multitest with integrated Bluetooth module Black plastic case DC adapter (220/0 V) with interchangeable international plugs 4 AAA.5 V batteries Bluetooth -USB dongle for wireless connection to your PC CD-ROM PrimeLab Desktop Assistant 2 24 mm standard round cuvette (glass / 0 ml) with light absorber integrated into lid Light protection lid for 6 mm standard cuvettes 0 ml syringe Cleaning brush for cuvettes Stirring rod Optional Adapter for MERCK 6 mm Prepared cuvettes 00 ml plastic measuring tube Filter unit for filtering water samples Technical details / features Dimensions: Weight: Sensor: Spectral range: Data Transmission: Calibration: One Time Zero: Internal memory: Clock / Date: Auto-Off: Menu navigation: Power supply: Display: Operating languages: Software and App: Cloud: (Handy) 75 mm 88 mm 59 mm (Light) 60 g Jencolor Multi Color Sensor 380 nm 780 nm with 7 open channels and ±40 nm overlap each Built-in Bluetooth -module Auto-calibration by JENCOLOR sensor; determination of LED brightness Intelligent OTZ (One Time Zero) function, detecting different ZERO types 00 data records / 20 accounts records RTC (real-time clock) with date function Default = 0 minutes. Individually adjustable Intuitive, display-controlled 4-button menu system; test instructions during the measurement process (can be skipped) optionally 4.5 V AAA batteries or V AC, 50/60 Hz, 0.2 A 5.0 V, 200mA, 6 W Graphical LCD display, monochrome German, English, Spanish, French More languages by using the App! Windows/Apple/Android Available as optional package Environment: 5 C 45 C (4 F 3 F) / 30 % 90 % rel. humidity PrimeLab Fluorescein-Adapter Fluorescein is a stable fluorescent tracer dye that emits green light with wavelengths between 520nm and 530 nm upon excitation with blue light with a maximum absorption at 495 nm. It provides an accurate, cost effective method for monitoring industrial boiler applications when a fixed known amount is added to dosage program. Once added to the water circulation system it is stable over time and is environmentally safe when dosed at the concentrations required for boiler water analysis. Water resistancy: Reagents: The unit is splash-proof The calibration curves of the individual parameters are matched to the reagents offered by the manufacturer. The use of reagents by other manufacturers may result in measurement errors! The scope of delivery of the PrimeLab includes solely high-quality reagents Made in Germany and Made in Britain! 40 4

22 PrimeLab Photometer - Parameters Parameters and Reagents List ID Parameter/Methode Test-Range Resolution Reagent Active Oxygen (MPS) Active Oxyg. (MPS) 0-40 mg/l 0. Tablet Alkalinity 5 Alkalinity-M mg/l Tablet 2 Alkalinity-M (HR) mg/l Tablet 6 Alkalinity P mg/l Tablet Aluminium 4 Aluminium mg/l 0.0 Tablet Ammonia 2 Ammonia (LR) 0 - mg/l 0.0 Tablet Boron 7 Boron 0-2 mg/l 0. Tablet Bromine 8 Bromine 0-8 mg/l 0.0 Tablet 63 Bromine 0-8 mg/l 0.0 Liq./Powd. 28 Bromine mg/l 0.0 Powder Carbohydrazide 7 Carbohydrazide mg/l 0.0 Liquid Chloramines (Mono-/Di-) 95 Chloramines 0-8 mg/l 0.0 Tablet Chloride 0 Chloride mg/l 0. Tablet 24 Chloride 0-00 mg/l 0. Liquid Chlorine Chlorine 0-8 mg/l 0.0 Tablet 2 Chlorine 0-8 mg/l 0.0 Liquid 22 Chlorine (MR) 0-0 mg/l 0.0 Tablet 5 Chlorine HR (KI) mg/l Liquid 4 Chlorine HR (KI) mg/l Tablet 29 Chlorine (free) 0-2 mg/l 0.0 Powder Chlorine Dioxide 6 Chlorine Dioxide 0-5 mg/l 0.0 Tablet 64 Chlorine Dioxide 0-5 mg/l 0.0 Liquid 08 Total Oxidant 0-8 mg/l 0.0 Liquid 30 Chlorine Dioxide 0-5 mg/l 0.0 Powder Chlorite 06 Chlorite 0-8 mg/l 0.0 Liquid Chromium (hexavalent) 94 Chromium (hexavalent) mg/l 0.0 Liquid 03 Chromium (hexavalent) 0 - mg/l 0.0 Liq./Powd. COD 79 COD (LR) 0-50 mg/l Prepared 80 COD (MR) mg/l Prepared 7 COD (HR) mg/l Prepared Colour 07 Colour mg/l - Copper 8 Copper 0-5 mg/l 0.0 Tablet 9 Copper 0-5 mg/l 0.0 Powder Cyanuric Acid 20 Cyanuric Acid 2-60 mg/l Tablet DBNPA 65 DBNPA 0-3 mg/l 0.0 Liquid 82 DBNPA 0-3 mg/l 0.0 Tablet DEHA 2 DEHA µg/l 0 Liquid Erythorbic Acid 70 Erythorbic Acid mg/l 0.0 Liquid Fluorescein 3 Fluorescein µg/l - Fluoride 72 Fluoride 0-2 mg/l 0.0 Liquid Hardness 78 Calcium Hardn mg/l Tablet 9 Calcium Hardn. (HR) mg/l Tablet 56 Total Hardn. (LR) 2-50 mg/l Tablet 57 Total Hardn. (HR) mg/l Tablet ID Parameter/Methode Test-Range Resolution Reagent 48 Hardness-Total (HR) mg/l Liquid Hydrazine 23 Hydrazine µg/l Liquid Hydrogen Peroxide 24 Hyd. Peroxide (LR) mg/l 0.0 Tablet 66 Hyd. Peroxide (LR) mg/l 0.0 Liquid 25 Hyd. Peroxide (HR) mg/l Liquid 09 DEWAN mg/l Liquid Hydroquinone 26 Hydroquinone mg/l 0.0 Liquid Iodine 27 Iodine 0-28 mg/l 0.0 Tablet 67 Iodine 0-28 mg/l 0.0 Liquid Iron 28 Iron (LR) 0 - mg/l 0.0 Tablet 29 Iron (MR) 0-0 mg/l 0.0 Powder 30 Iron (HR) 0-30 mg/l 0.0 Liquid 27 Iron MR (Ferrous) 0-0 mg/l 0.0 Powder 32 Iron-total (LR) 0-3 mg/l 0.0 Powder 49 Iron in oil mg/l Liquid Isothiazolinone 88 Isothiazolinone 0-0 mg/l 0. Liquid Legionella 47 Legionella cfu/l Liquid Magnesium 93 Magnesium 0-00 mg/l Tablet Magnanese 3 Manganese (LR) mg/l 0. Tablet Methylethylketoxime 69 Methylethylketoxime 0-4. mg/l 0.0 Liquid Molybdate 96 Molybdate (LR) 0-5 mg/l 0.0 Tablet 32 Molybdate (HR) - 00 mg/l 0. Tablet 33 Molybdate (HR) mg/l 0. Liquid 34 Molybdate (HR) 0-40 mg/l 0. Powder Nickel 90 Nickel (HR) 0-7 mg/l 0. Tablet 00 Nickel (HR) 0-0 mg/l 0. Liquid Nitrate 34 Nitrate 0 - mg/l 0. Liq./Powd. Nitrite 35 Nitrite (LR) mg/l 0.0 Tablet 36 Nitrite (HR) mg/l 0. Powder 97 Nitrite (HR) mg/l Tablet 0 Nitrite (HR) mg/l Liquid Ozone 37 Ozone mg/l 0.0 Tablet 92 Ozone mg/l 0. Liquid ph 40 ph-value (LR) Tablet 38 ph-value (MR) Tablet 39 ph-value (MR) Liquid 4 ph-universal 5-0. Tablet 42 ph-universal 4-0. Liquid Phenol 98 Phenol 0-5 mg/l 0.0 Tablet PHMB 43 PHMB 2-60 mg/l Tablet Phosphate 44 Phosphate (LR) 0-4 mg/l 0.0 Tablet 45 Phosphate (LR) 0-4 mg/l 0.0 Liq./Powd. 46 Phosphate (HR) 0-80 mg/l 0. Tablet 47 Phosphate (HR) 0-00 mg/l 0. Liquid Phosphonate 87 Phosphonate 0-20 mg/l 0.0 Liquid 0 Phosphonate 0-20 mg/l 0.0 Tablet ID Parameter/Methode Test-Range Resolution Reagent Polyacrylate 85 Polyacrylate - 30 mg/l 0. Liquid Polyamine 25 Acsamine 28F 0-00 mg/l Liquid 26 Acsamine DW 0-00 mg/l Liquid 4 Acsamine DWBR 0-00 mg/l Liquid 42 Acsamine DWC 0-00 mg/l Liquid 43 Acsamine SW 0-00 mg/l Liquid 44 Acsamine SWC 0-00 mg/l Liquid 45 Acsamine CC 0-00 mg/l Liquid 46 Acsamine CCA 0-00 mg/l Liquid Potassium 48 Potassium mg/l 0. Tablet PTSA PTSA µg/l - QAC 83 QAC mg/l Tablet Silicia 49 Silica (LR) 0-5 mg/l 0.0 Liq./Powd. 50 Silica (HR) 0-00 mg/l Powder Sodium Hypochlorite 5 Sodium Hypochlorite % 0. Tablet 68 Sodium Hypochlorite % 0. Liquid Sulphate 54 Sulphate 5-00 mg/l Tablet 55 Sulphate 5-00 mg/l Powder Sulphide 52 Sulphide mg/l 0.0 Tablet 40 Sulphide Liquid Sulphite 53 Sulphite (LR) 0-5 mg/l 0. Tablet 05 Sulphite (HR) mg/l 0. Tablet Suspended solids 8 Suspended solids mg/l - Tannic acid 9 Tannic acid 0-50 mg/l 0. Liquid Transmission 4 Transmission-420 nm 0-00 % Transmission-470 nm 0-00 % Transmission-520 nm 0-00 % Transmission-570 nm 0-00 % Transmission-620 nm 0-00 % Transmission-670 nm 0-00 % 0. - Turbidity 59 Turbidity FAU - 2 Turbidity NTU Urea 20 Urea mg/l 0. Liq. / Tabl. 50 Urea (HR) mg/l 0. Liq. / Tabl. Zinc 62 Zinc 0 - mg/l 0.0 Tablet We design individual kits for you such as this Marine Kit! Installed parameters / measurement methods The parameters / measurement methods installed on the PrimeLab may be individually defined by the user and extended at any time after purchase by entering activation codes into the software. Thus also subsequently developed measurement methods can still be installed. The PrimeLab will never become obsolete. Parameter-Code Code: Attention Contact your dealer to learn about how to receive a code Cancel Please enter a CODE OK Activate The activation of the parameter 38-pH-MR-tab has been performed successfully. New reagents are being constantly developed! Check out for the latest list! 42 43

23 Electronic Meter Dip and read Using Water-i.d Electronic Meters is really easy. After calibrating, the device only needs to be switched on and held in the liquid that needs to be tested. The device determines the measurement value promptly and shows it on the display. The Electronic Meter should be adjusted/calibrated in regular intervals; preferably immediately prior to each measurement. This is done by dipping the device in a sachet containing a reference liquid and then manually turning a small screw to the reference value turning up on the display. Background Without requiring additional reagents (tablets, drops, etc.) Electronic Meters offer an professional way to measure various water values, such as conductivity, salinity (total dissolved solids) and ph. The test result is displayed on the device within seconds after dipping the device into the water sample. The sensitive electrodes should always be kept wet and calibrated at regular intervals, preferably before each measurement, by using a reference fluid. The working range of the Electronic Meter is between 0-50 C. Depending on the model, temperature can be compensated for by determining the measurement value. All Water-i.d Distinguishing Features Electronic Meters are waterproof and can be used directly on site like in swimmingpools or in an aquarium. Because they are calibrated manually, Water-i.d Electronic Meters are price-effective and are an attractive alternative to current test processes; such as, for example, Pooltesters or Comparators. The model as shown aside comes in a leather-like pouch with a belt clip on it s back side. Water is H2O, hydrogen two parts, oxygen one, but there is a third thing, that makes water and noboy knows what it is (D. H. Lawrence, Pansies) 44 45

24 Electronic Meter Product Description Measurement- Range Resolution Precision Calibration Aut. Temp.- Compens. Batteries (shelf life) Conditions Dimensions (Weight) Reference Solut. FT Electronic ph Meter ph ( ) 0. ph +/- 0. ph point, manual x,5 V (.000 h) 0-50 C, RH 00% 53 x 24 mm (45g) 7.00 ph (20ml Sachet) FT5 Electronic ph Meter with Temperature reading ph ( ) Temp. (-5-50 C) 0.0 ph 0. C +/- 0. ph +/- C point, manual automatic 4 x,5 V (50 h) 0-50 C, RH 00% 95 x 95 mm (25 g) 7.00 ph (20ml Sachet) FT34 Electronic TDS Meter (Total dissolved solids) TDS (0-999 ppm) ( ppt) ppm +/- 2% FS point, manual automatic 0-50 C mit ß=2%/ C 3 x,5 V (250 h) 0-50 C, RH 00% 53 x 24 mm (45g) 382 TDS (20ml Sachet) FT36 Electronic TDS Meter (Total dissolved solids) TDS ( ppm) ( ppt) 0.0 ppt +/- 2% FS point, manual automatic 0-50 C mit ß=2%/ C 4 x,5 V (250 h) 0-50 C, RH 00% 53 x 24 mm (45g) 6.44 TDS (20ml Sachet) FT33 Electronic EC Meter (Electronic Conductivity) EC (0-999 µs/cm) ( ms/cm) µs/cm +/- 2% FS point, manual automatic 0-50 C mit ß=2%/ C 3 x,5 V (250 h) 0-50 C, RH 00% 53 x 24 mm (45g) 43 µs/cm (20ml Sachet) FT35 Electronic EC Meter (Electronic Conductivity) EC ( µs/cm) ( ms/cm) 0.0 ms/cm +/- 2% FS point, manual automatic 0-50 C mit ß=2%/ C 3 x,5 V (250 h) 0-50 C, RH 00% 53 x 24 mm (45g) 2.88 ms/cm (20ml Sachet) FT FT40 Electronic Meter for ph-, ORP-(Redox) and Temperature ph ( ) ORP (+/-999mV) Temp. (0-50 C) 0.0 ph mv 0. C +/- 0. ph +/- 5mV +/- C point, manual automatic 0-50 C mit ß=2%/ C 4 x,5 V (50 h) 0-50 C, RH 00% 70 x 40 mm (00g) 7.00 ph (20ml) 468 mv (00ml) Reference Solutions and Spares Emphbuf700 Emphbuf400 Emphbuf00 Emtdsbuf500 Emtdsbuf644 Emecbuf43 Emecbuf288 Product Description Ref. Solution 7.00 ph Ref. Solution 4.00 ph Ref. Solution 0.00 ph Ref. Solution 500 ppm TDS Ref. Solution 6.44 ppt TDS Ref. Solution 43 µs/cm EC Ref. Solution 2.88 ms/cm EC for Electronic Meter FT FT5 FT33 FT34 FT35 FT36 FT40 Emorpbuf468 Spbat3 Spbat30 Ref. Solution 468mV (3 x),5 V Battery (30 x),5 V Battery FT40 FT

25 Bacteria testing Dipslides with flexible paddle The definition of a dipslide is a means of testing the microbial content of liquids or surfaces. It consists of a plastic carrier bearing a sterile culture medium which can be dipped in the liquid or pressed on to the surface to be sampled. It is than incubated for 48 hours at 30 C to allow microbial growth. The resulting microbial colonies are estimated by reference to a chart. If the treatment programme is effective, the dipslide count will be consistently low 4 (<0 ). If a high result is obtained, the test should be repeated and the treatment programme checked. Water-i.d dipslides for bacterial testing are provided as 0 dipslides in a box. A variety of incubators is offered as well. Background Distinguishing Features The flexible paddle allows convenient surface testing. Bacteria testing is mostly common for detecting slime forming bacteria in cooling & industrial waters, storage tanks as well as in metal-working fluids, paper processing waters, fuel tanks etc. Public swimming pools do also often test on legionella and other bacterias to get a better idea about how effective desinfectants are which are used. There is magic on the planet, it is contained in water. (Loren Eisley) 48 49

26 Bacteria Tests Bacteria testing Quality products made in the UK Dipslide Tests BactD00 Product Description TTC/TTC Dipslide Tests for Total Viable Count in waters and surfaces. Flexible paddle for effective surface contact. quantity of tests per pack 0 BactD002 Malt/TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count in waters and surfaces. Flexible paddle for effective surface contact. 0 BactD003 RBS/TTC Dipslide Tests for Yeasts, Moulds, Fungi and Total Viable Count for food and manufacturing industry. Flexible paddle for effective surface contact. 0 BactD004 BactD005 MAC/TTC Dipslide Tests for Coliforms and Total Viable count in process water. Flexible paddle for effective surface contact. Chromogenic/TTC Dipslide Tests for E.coli, Pseudomonas Aeruginosa and Total Viable Count for enumeration of E.coli. Flexible paddle for effective surface contact. 0 0 Flexible paddle BactD006 PDM/MAC Dipslide Tests for Pseudomonas species and Coliforms for potable water, pools and spas. Flexible paddle for effective surface contact. 0 BactD007 BactD008 BactD009 PDM/TTC Dipslide Tests for Pseudomonas species and Total Viable Count for Closed water systems, pools and spas. Flexible paddle for effective surface contact. SRB Tube Tests for Sulphate reducing bacteria in Closed water systems. Flexible paddle for effective surface contact. NRB Tube Tests for Nitrite reducing bacteria in Closed water systems. Flexible paddle for effective surface contact Incubators BactEDT057 BactEDT055 Product Description Incubator for 2 Dipslide Tests. Preset to 30 C. Incubator for 8 Dipslide Tests. With temperature gauge and adjustable temperature. Maximum dipslide qty 2 8 Voltage 0 / 220 V 2 / 0 / 220 V BactEDT059 Incubator for 0 Dipslide Tests. With temperature gauge and adjustable temperature. Ideal for NRB/SRB tests. Only offered with 240 V V BactEDT052 Incubator for 25 Dipslide Tests. With temperature gauge and adjustable temperature / 0 / 220 V BactEDT093 Incubator for 45 Dipslide Tests. With temperature gauge and adjustable temperature / 0 / 220 V BactEDT-2V 2V car-lead for BactEDT057/BactEDT055/ BactEDT052/BactEDT093 2 V BactEDT057 BactEDT055 BactEDT059 BactEDT052 BactEDT

WATER TESTING EQUIPMENT 2014

WATER TESTING EQUIPMENT 2014 WATER TESTING EQUIPMENT 204 MAIN CATALOGUE WATER - ANALYSIS The Pool-i.d. Group Headquarter and Factory: Pool-i.d. GmbH Daimlerstr. 20 7644 Eggenstein Germany Tel. +49 (0) 72-78 20 29-0 Fax. +49 (0) 72-78

More information

V Catalogue

V Catalogue V17.11 2018 Catalogue Valid until Dec. 31st, 2018 Water-i.d. 2018 English 10 Parameters: The new PoolLab 1.0 is a triple wavelength (530 / 570 / 620nm) photometer for professional water analysis of private

More information

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water. Comparator 2000+ The system for colorimetric water analysis Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing

More information

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Page A2 A4 A6 A20 A1 Single Parameter Simple and Economical Analysis HANNA instruments test kits are the

More information

Comparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards

Comparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards Comparator 2000+ Colorimeter for regular testing in public pools & spas with colour-stable glass standards 24 www.lovibond.com Pool & Spa Water Testing - January 2013 Comparator 2000+ With its accessories,

More information

Specification and Certificate of Analysis

Specification and Certificate of Analysis Reagents Green chemistry For decades, the Tintometer Group has been known as a producer of reagents for water analysis, which are supplied under the brand name Lovibond. The wide range of applications

More information

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

HI Multiparameter Photometers with up to 44 Measurement Methods.  ISO 9001:2000 Certified HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to 44 Measurement Methods ISO 9001:2000 Certified www.hannainst.com/usa HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to

More information

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers DelAgua Safe Water Reagent Identification Chart for Lovibond Tintometer photometers For Use: Identify the parameter required, ensure the parameter matches your photometer, codes required for the test are

More information

with IP67 BOOTH #2832

with IP67 BOOTH #2832 with IP67 4 BOOTH #2832 The new exact idip by Industrial Test Systems, Inc. (ITS is the first product in the recreational water testing market to provide complete wireless connectivity between the iphone,

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Chlorine T a) 0.01-6.0 mg/l Cl 2 DPD 100 CL6 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

DR 1900 PORTABLE SPECTROPHOTOMETER

DR 1900 PORTABLE SPECTROPHOTOMETER DR 1900 PORTABLE SPECTROPHOTOMETER Applications Drinking Water Wastewater Field Use Industrial Water Power Carry more water methods with you wherever you need them most. The DR 1900 combines the ruggedness

More information

Lovibond Water Testing. Tintometer Group. General Catalogue. General Catalogue. Instruments and Reagents for Today s Water Analysis.

Lovibond Water Testing. Tintometer Group. General Catalogue. General Catalogue. Instruments and Reagents for Today s Water Analysis. General Catalogue Lovibond Water Testing Tintometer Group General Catalogue Instruments and Reagents for Today s Water Analysis www.lovibond.com PHILOSOPHY Water is the basis of life. And it also provides

More information

Sustainability and environmental protection. Tintometer places great importance on sustainability and the sensitive use of natural resources.

Sustainability and environmental protection. Tintometer places great importance on sustainability and the sensitive use of natural resources. Tintometer -Group There are very few companies which can look back over a history of more than 125 years of success. The reason we can do so lies in the world-wide appreciation of our products and the

More information

AQUALYTIC. Parameter, Ranges and Reagents for. Chloride 530 Silver nitrate/turbidity mg/l Cl

AQUALYTIC. Parameter, Ranges and Reagents for. Chloride 530 Silver nitrate/turbidity mg/l Cl AQUALYTIC Parameter, Ranges and Reagents for Test λ a) / nm Method Range Display Alkalinity-m (total) 610 Acid/Indicator 1, 2 5-200 mg/l CaCO 3 Alkalinity-p 560 Acid/Indicator 1, 2 5-500 mg/l CaCO 3 Aluminium

More information

DR /2400 and DREL /2400 Spectrophotometer + Portable Laboratories. Get moving with the DR/ 2400 spectrophotometer: Made-to-measure in situ analysis

DR /2400 and DREL /2400 Spectrophotometer + Portable Laboratories. Get moving with the DR/ 2400 spectrophotometer: Made-to-measure in situ analysis DR /2400 and DREL /2400 Spectrophotometer + Portable Laboratories Get moving with the DR/ 2400 spectrophotometer: Made-to-measure in situ analysis DR /2400 Spectrophotometer All systems go! DR/2400 Contemporary

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Pool & Spa Water Treatment and Analysis The handbook includes detailed information

More information

Portable photometer for field and laboratory use

Portable photometer for field and laboratory use Portable photometer for field and laboratory use MACHEREY-NAGEL www.mn-net.com MN Application with VISOCOLOR reagents The photometer PF-11 offers an easy start into photometric water analysis. When evaluated

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Chlorine VARIO PP a) 0.02-3.5 mg/l Cl 2 DPD 113 CL2 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the

More information

ALKALINITY (ALKAPHOT)

ALKALINITY (ALKAPHOT) PHOT.2.AUTO TEST INSTRUCTIONS ALKALINITY (ALKAPHOT) TEST FOR TOTAL ALKALINITY IN NATURAL AND TREATED WATERS Photometer Method AUTOMATIC WAVELENGTH SELECTION 0 500 mg/l CaCO 3 Natural and treated waters

More information

TECHNICAL SPECIFICATIONS FOR A MOBILE LABORATORY 2014

TECHNICAL SPECIFICATIONS FOR A MOBILE LABORATORY 2014 ZAMBIA BUREAU OF STANDARDS TESTING LABORATORIES TECHNICAL SPECIFICATIONS FOR A MOBILE LABORATORY 2014 Annex I Item Description Quantity 1 MOBILE LAB VEHICLE SPECIFICATION 1 To be used as a platform where

More information

MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Copper T 0.05-5 mg/l Cu a) Biquinoline 150 Cu Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Photometer-System using Dual Beam Technology

Photometer-System using Dual Beam Technology Tintometer Photometer-System using Dual Beam Technology Dual Beam Technology and Interference Filters for best accuracy 44 Applications Waste Water Drinking Water Industrial Process Water Scientific Applications

More information

Copper 50 T mg/l Cu a) Biquinoline

Copper 50 T mg/l Cu a) Biquinoline Copper 50 T 0.05-1 mg/l Cu a) Biquinoline 149 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Iron 10 T mg/l Fe Ferrozine / Thioglycolate

Iron 10 T mg/l Fe Ferrozine / Thioglycolate Iron 10 T 0.05-1 mg/l Fe Ferrozine / Thioglycolate 218 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of

More information

GeneralCatalogue. GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents. Edition: April 2018

GeneralCatalogue. GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents. Edition: April 2018 Edition: April 2018 GeneralCatalogue GeneralCatalogue WaterAnalysis EnvironmentalAnalysis TestEquipment Reagents AQUALYTIC is a leading manufacturer of equipment for water and wastewater analysis, specializing

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Bromine T 0.05-13 mg/l Br 2 DPD 80 Br Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are

More information

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive

More information

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries Please visit our website at thermofisher.com/mastermethods for the latest instructions for Thermo

More information

WATER TEST KITS PRICE LIST 2017

WATER TEST KITS PRICE LIST 2017 WATER TEST KITS PRICE LIST 2017 Water Treatment Products, Unit 1, Gilchrist Thomas Industrial Estate, Blaenavon, Torfaen NP4 9RL T: 01495 792790 F: 01495 792090 E: sales@watertreatmentproducts.co.uk www.watertreatmentproducts.co.uk

More information

9100 UV-Vis Spectrophotometer

9100 UV-Vis Spectrophotometer 9100 UV-Vis Spectrophotometer Palintest 9100 UV-Vis Spectrophotometer UV-Vis spectroscopy from Palintest Ltd utilises the full range of formulated applications for drinking water, wastewater and industrial

More information

Photometer-System P 620. Instruction manual

Photometer-System P 620. Instruction manual Photometer-System P 620 GB Instruction manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into

More information

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part

More information

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D

More information

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive

More information

AUTOMATED WATER ANALYSIS

AUTOMATED WATER ANALYSIS APPLICATION NOTE - CFA AUTOMATED WATER ANALYSIS APPLICATIONS OF CONTINUOUS-FLOW ANALYZERS In laboratories around the world, the SEAL Analytical analyzers measure all types of water - quickly, accurately

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Silicate HR VARIO PP 1-100 mg/l SiO 2 Silicomolybdate 352 SiHr Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range

More information

SENSOR TECHNOLOGY RANGE

SENSOR TECHNOLOGY RANGE SENSOR TECHNOLOGY RANGE About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive range of precision instruments for multidisciplinary

More information

NEW. Multiparameter Photometers. with Advanced Optics and ph Meter

NEW. Multiparameter Photometers. with Advanced Optics and ph Meter NEW Multiparameter Photometers with Advanced Optics and ph Meter Multiparameter Photometers The HI83300 family of multiparameter photometers features nine models to cover a wide variety of applications.

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Swimming and Spa Pool Water Treatment The handbook includes detailed information

More information

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at:

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at: Visit our Web Site HFscientific.com Water Quality Measurement Solutions Online Water Testing Product Sampler 2016 Field Laboratory 3170 Old Metro Parkway Ft. Myers, FL 33916 www.hfscientific.com toll free:

More information

Palintest TABLET COUNT TESTS TAB.1 INSTRUCTIONS FOR USING THE PALINTEST TABLET COUNT METHOD OF WATER ANALYSIS

Palintest TABLET COUNT TESTS TAB.1 INSTRUCTIONS FOR USING THE PALINTEST TABLET COUNT METHOD OF WATER ANALYSIS Palintest TAB.1 TEST INSTRUCTIONS TABLET COUNT TESTS INSTRUCTIONS FOR USING THE PALINTEST TABLET COUNT METHOD OF WATER ANALYSIS The Palintest Tablet Count method provides an extremely easy means of analysis

More information

DR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis

DR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis DR/800 Series Colorimeters High-Value, High-Capability Instruments for Water Quality Analysis DR/800 Series Colorimeters Hach DR/800 Series Colorimeters combine ease of use, multiple testing capabilities

More information

Test sticks and test papers for semi-quantitative determinations

Test sticks and test papers for semi-quantitative determinations QUANTOFIX test sticks for semi-quantitative determinations QUANTOFIX test sticks meet the most important requirements for a modern quick-test: rapid dip and read convenient the analysis can be carried

More information

SENSOR TECHNOLOGY RANGE

SENSOR TECHNOLOGY RANGE SENSOR TECHNOLOGY RANGE About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive range of precision instruments for multidisciplinary

More information

Advancements in Field Testing Equipment

Advancements in Field Testing Equipment Advancements in Field Testing Equipment What will we be covering? Why do we field sample? What do we use to field sample? Why Do We Sample? Regulations or Permits Am I in compliance? Process control Is

More information

SUMMARY OF STANDARDS FOR WATER ANALYSIS ON COURSE WAT-E2120 SPRING 2017

SUMMARY OF STANDARDS FOR WATER ANALYSIS ON COURSE WAT-E2120 SPRING 2017 SUMMARY OF STANDARDS FOR WATER ANALYSIS ON COURSE WAT-E2120 SPRING 2017 - electrical conductivity - turbidity - NPOC - color - COD Mn - UV-absorbance - bacteria - total iron Edited by Aino 1 Determination

More information

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand Environment, Central Mine Planning and Design Institute Last Amended on - Page 1 of 9 1. POLLUTION & EFFLUENTS 1. Effluent / Waste Water Ammonical Nitrogen Free Ammonia IS 3025 (Part 34):1988, Nessler

More information

Nitrogen, Simplified TKN (s-tkn ) DOC

Nitrogen, Simplified TKN (s-tkn ) DOC Nitrogen, Simplified Total Kjeldahl, TNTplus 880, 10242 DOC316.53.01258 s-tkn Method Method 10242 0 to 16 mg/l TKN TNTplus 880 Scope and Application: For water and wastewater. Digestion is required. Test

More information

Boiler Water No.2 Test Kit Instruction Manual

Boiler Water No.2 Test Kit Instruction Manual Boiler Water No.2 Test Kit Instruction Manual BOILER WATER No.2 Steam boilers require careful treatment in order to maintain efficiency, steam purity and to prevent scale and corrosion of pipework and

More information

Water Analysiss. Solutions for photometry

Water Analysiss. Solutions for photometry Water Analysiss Reag gents OR Reag NANOCOLOR OR Solutions for photometry Bar coded tube tests with pre-dosed reagents For highest accuracy and sensitivity in water analysis NANOCONTROL for analytical quality

More information

IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING

IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING Micro 0 Revision 0// 8700-K Standard Kit 8700-WD Well Driller Kit 8700-KP Pool Kit Dual Wavelength Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING

More information

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

TURBIDITY TB 300 IR TB 210 IR TB 250 WL.  General Catalogue April 2015 TURBIDITY 128 TB 300 IR TB 210 IR TB 250 WL www.lovibond.com General Catalogue April 2015 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid or solid

More information

Environmental Chemistry - Water HL

Environmental Chemistry - Water HL Name: Environmental Chemistry: Water 19. Environmental Chemistry - Water Objectives -define hardness in water -define temporary hardness in water -define permanent hardness in water -identify the causes

More information

IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING

IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING Revision 06/03/13 486696-PLUSK Kit Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING Use in accordance with U.S. Patent #7,333,194 &

More information

Why Hach Reagents? Alphabetical Listing of Reagents

Why Hach Reagents? Alphabetical Listing of Reagents Why Hach Reagents? Hach Chemical Reagents Formulated to minimize interferences, test complexity and analysis time Confirmed test performance by chemists who understand your application Designed for Maximum

More information

Instruction Manual GB

Instruction Manual GB Instruction Manual GB Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the hands of children.

More information

Instruction Manual GB

Instruction Manual GB Instruction Manual GB Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the hands of children.

More information

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside!

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside! Laboratory & Field Instruments: See Inside! Quick Reference Guide See pages 86-87. for Spectrophotometers and Colorimeters See pages 88-90. for Turbidimeters See pages 90. Pour-Thru See pages 91. Quick

More information

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS Paper Presented by: Shane Jordan-Hill Author: Shane Jordan-Hill, Business Manager Environmental Analysis, Merck Millipore 6 th Annual

More information

Available tests for the photometer MD600 / MaxiDirect New Tests

Available tests for the photometer MD600 / MaxiDirect New Tests Available tests for the photometer MD600 / MaxiDirect New s 20 Acid demand ph 4.3 T 610 Acid / Indicator 1, 2 0.1-4 mmol/l ALKA-M PHOTOMETER 513210BT 30 Alkalinity-m T (total) 610 Acid / Indicator 1, 2

More information

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2011. Edition: 11/07

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2011. Edition: 11/07 Pool & Spa Water Analysis Instruments and Reagents Edition: 03/2011 Edition: 11/07 Lovibond -Handbook Swimming and Spa Pool Water Treatment The handbook includes detailed information on topics relating

More information

Calibration and Standards. AMCO Standards for use in Drinking Water Analysis

Calibration and Standards. AMCO Standards for use in Drinking Water Analysis Quality Control using Measurements measurements are of extreme importance in quality monitoring in water, wastewater, beverage production, electroplating and petrochemical applications. Typical turbidity

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Hardness Calcium (B) T 0-500 mg/l CaCO 3 Murexide 191 CAH Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range

More information

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE- ON LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, 38240 MEYLAN -FRANCE- TEL : +33 4 76 41 86 39 - FAX : +33 4 76 41 92 27 MAIL : SALES@TETHYS-INSTRUMENTS.COM - WEB : WWW.TETHYS-INSTRUMENTS.COM

More information

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2009. Edition: 11/07

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2009. Edition: 11/07 Pool & Spa Water Analysis Instruments and Reagents Edition: 03/2009 Edition: 11/07 Pool- & Spa Water Testing Instruments and Reagents for reliable Water Analysis There are very few companies which can

More information

Boiler Water No.1 Test Kit Instruction Manual

Boiler Water No.1 Test Kit Instruction Manual Boiler Water No.1 Test Kit Instruction Manual Steam boilers require careful treatment in order to maintain efficiency, steam purity and to prevent scale and corrosion of pipework and heat exchangers. The

More information

Nexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka

Nexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka Certificate Number TC-5069 (in lieu of T-3362 & T-3363) Page 1 of 17 Range ing / BIOLOGICAL TESTING I. WATER 1. Drinking Water R.O. Water, Ground Water, Surface Water, Treated Water. 2. Waste Water/ Effluents

More information

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Method (0.1 to 8.0 mg/l Cu) TNTplus 860 Chlorine, Total, Bulk Powder, 8167 DOC316.53.01255 Bathocuproine Method 1 Method 10238 (0.1 to 8.0 mg/l Cu) TNTplus 860 Scope and Application: For water, wastewater and process water. Digestion may be

More information

Water Test Kits Price List 2017

Water Test Kits Price List 2017 Water Test Kits Price List 2017 We are 8 the specialists in OWN BRAND LABELLING of chemical products Water Treatment Products, Unit 1, Gilchrist Thomas Industrial Estate, Blaenavon, Torfaen NP4 9RL T:

More information

GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents

GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents GeneralCatalogue WaterAnalysis EnvironmentalAnalysis TestEquipment Reagents AQUALYTIC is a leading manufacturer of equipment for water and wastewater analysis, specializing in BOD measurement and photometry.

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Pool & Spa Water Treatment and Analysis The handbook includes detailed information

More information

Q u a l i t y C o n t r o l U s i n g Tu r b i d i t y Measurements

Q u a l i t y C o n t r o l U s i n g Tu r b i d i t y Measurements Turbidity Measurements Q u a l i t y C o n t r o l U s i n g Tu r b i d i t y Measurements Turbidity measurements are of extreme importance in quality monitoring in water, wastewater, beverage production,

More information

C 99 & C 200 Series Multiparameter Bench Photometers

C 99 & C 200 Series Multiparameter Bench Photometers Instruction Manual C 99 & C 200 Series Multiparameter Bench Photometers Manufacturers since 1978 These Instruments are in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna

More information

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY THE WATER ACT, 1956 (ACT 54 OF 1956 ) AND ITS REQUIREMENTS IN TERMS OF WATER SUPPLIES FOR DRINKING WATER AND FOR WASTE WATER TREATMENT AND DISCHARGE INTO THE ENVIRONMENT 1. INTRODUCTION The provisions

More information

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m

More information

Checker HC. Handheld Colorimeters

Checker HC. Handheld Colorimeters Checker HC Hanna Checker HC Series The Hanna Checker HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10

More information

With Discovery Incubator.

With Discovery Incubator. TEST KIT POTABLE WATER With Discovery Incubator. FEATURES & BENEFITS 8 dip slide capacity Compact and convenient design Weighs only 1.2 kg Temperature range: ambient +5 to 45 C Accurate temperature control

More information

Advanced Photometer System

Advanced Photometer System Revision 06/07/2 Standard Kit Starter Kit Advanced Photometer System IDEAL FOR TESTING POOLS AND SPAS. ACCEPTED BY MOST HEALTH DEPARTMENTS FOR COMMERCIAL POOL AND SPA TESTING. USEPA, DIN, & ISO Compliant

More information

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm Document: AND016 04 2014 Cadmium Testing and On Site Calibration for Water Testing Detection Range: 0.1 1.0ppm April, 2014 Edition 3 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of

More information

Basic Single Parameter Test Kits

Basic Single Parameter Test Kits Basic Single Parameter Test Kits D rop Test s Test kits are contained within a carry case and include weatherproof instructions, a sample pot, syringe and reagents for approximately 100-200 tests. Parameter

More information

Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS AND SPAS, ENVIRONMENTAL, & EDUCATIONAL TESTING

Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS AND SPAS, ENVIRONMENTAL, & EDUCATIONAL TESTING Micro 7+ Advanced Photometer System Revision 05/6/3 48669-K Standard Kit IDEAL FOR DRINKING WATER, POOLS AND SPAS, ENVIRONMENTAL, & EDUCATIONAL TESTING USEPA, DIN, & ISO Compliant for Free & Total Chlorine

More information

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter HI 98703 EPA Compliant Turbidity Meter HI 93414 EPA Compliant Turbidity and Chlorine Meter SPECIFICATIONS Turbidity (HI 93414 & HI 98703) Range Range Selection ACCESSORIES HI 710005 Voltage adapter HI

More information

EPA Compliant Turbidity & Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter EPA Compliant Turbidity & Chlorine Meter New Turbidity Technology from HANNA HANNA s new HI 98703 and HI 93414 utilize an EPA compliant tungsten light source and state-of-the-art optical system that allow

More information

ADVANCED PHOTOMETER SYSTEM

ADVANCED PHOTOMETER SYSTEM Chlorine+ ADVANCED PHOTOMETER SYSTEM DIGITAL ACCURACY FOR RELIABLE WATER CARE Certified to NSF/ANSI Standard 50 QUICK START GUIDE 2 CONTENTS Welcome............................................. 2 Chlorine

More information

Phosphorus, Reactive (Orthophosphate)

Phosphorus, Reactive (Orthophosphate) Phosphorus, Reactive (Orthophosphate) DOC316.53.01118 USEPA 1, 2 PhosVer 3 Method 3 Method 8048 0.06 to 5.00 mg/l PO 4 (0.02 to 1.60 mg/l P) Test N Tube Vials Scope and application: For drinking water,

More information

Photometer-System PC 6 in one

Photometer-System PC 6 in one Photometer-System PC 6 in one Cl Br ph Cys Alk CaH Tablet GB Instruction Manual Page 3 23 2 PC 6 in one_1 06/2010 GB Contents General notes...4 Guidelines for photometric measurements.................................

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10129 ORGANIC CARBON, TOTAL, Low Range (0.0 20.0 mg/l C) Direct Method * For water, drinking water, and wastewater HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103-105 C. Note: See DRB 200

More information

SOIL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SWIMMING POOL TEST KIT

SOIL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SWIMMING POOL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SOIL TEST KIT SWIMMING POOL TEST KIT 01 Analyzing Waters Anytime... Anywhere... AQUASOL test kits are extremely simple and easy to use & make monitoring convenient

More information

Oxygen Demand, Chemical

Oxygen Demand, Chemical Oxygen Demand, Chemical DOC316.53.01101 Manganese III Reactor Digestion Method (with chloride removal) Method 10067 30 to 1000 mg/l COD Mn Test N Tube Vials Scope and application: For water and wastewater

More information

Prakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat

Prakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat Prakruti Environmental Engineers (Environmental ), Last Amended on - Page 1 of 7 I. WATER 1. Water (Ground Water/ Surface Water/ Drinking Water/ Treated Water) ph APHA 4500-H + B, Temperature APHA 2550

More information

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal Last Amended on - Page 1 of 16 I. WATER 1. Drinking Water ph IS 3025 (Part 2): 2004, Colour APHA (22 nd Edition) 2120 B: Turbidity (NTU) IS 3025 (Part 10): 1984 Residual, Free Chlorine IS 3025 Part 26/1986

More information

Nitrogen, Simplified TKN (s-tkn )

Nitrogen, Simplified TKN (s-tkn ) Nitrogen, Simplified TKN (s-tkn ) DOC316.53.01258 s-tkn Method Method 10242 1 0 to 16 mg/l TKN TNTplus 880 Scope and application: For water and wastewater. Digestion is required. 1 USEPA approved for water

More information

Checker. Handheld Colorimeters

Checker. Handheld Colorimeters Checker Handheld Colorimeters Features Easier to use and more accurate than chemical test kits High accuracy Large, easy to read digits Auto shut off Eliminates subjectivity Dedicated to a single parameter

More information

Chemical Oxygen Demand

Chemical Oxygen Demand HI83314 Multiparameter Photometer with COD for Wastewater with Digital ph Electrode Input HI83314 photometer measures 10 different key wastewater quality parameters using 20 different methods that allow

More information

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb Document: AND Uranium 100 10 2012 Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb October, 2012 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table

More information

Turbimax CUE25 / CUE26

Turbimax CUE25 / CUE26 Technical Information Turbimax CUE25 / CUE26 Handheld turbidimeter for field measurement Application Turbimax CUE25 / CUE26 are compact handheld meters for the measurement of turbidity in the field. They

More information

Water Analysis. NANOCOLOR Automatic turbidity check for tube tests. Maximum result safety MACHEREY-NAGEL.

Water Analysis. NANOCOLOR Automatic turbidity check for tube tests. Maximum result safety MACHEREY-NAGEL. Water Analysis NANOCOLOR Automatic turbidity check for tube tests Maximum result safety MACHEREY-NAGEL Automatic turbidity check Turbidity a source of error in photometry As a source of error in photometry,

More information

INSTRUCTION MANUAL. ba76126e01 03/2013. photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y

INSTRUCTION MANUAL. ba76126e01 03/2013. photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y INSTRUCTION MANUAL photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y photoflex Series For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725

More information