Nominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR
|
|
- Bartholomew Fox
- 6 years ago
- Views:
Transcription
1 C O A X I A L C A B L E S Oh Coax Lengths 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel Silver-coated Copper Braid Shield TFE Teflon Insulation White FEP Jacket 200 C AWG SCC Braid % VW (7x38) 96% Shield Coverage 14.6Ω/M 47.9Ω/k 801.0Ω/k M17/ (RG-178B/U). Non-SWR swept version RG-178. DCR Shielding OD Inch DCR Inch AWG Stranded (7x.006 ).020 Silver-coated Copper-covered Steel 95% Silver-coated Copper Braid Shield TFE Teflon Insulation White FEP Jacket 200 C AWG SCC Braid % VW (7x.006 ) 95% Shield Coverage 6.5Ω/M 84.1Ω/M 27.9Ω/k 275.9Ω/k M17/ (RG-316/U). Non-SWR swept version RG-316. TFE Teflon Insulation Brown FEP Jacket 200 C AWG SCC Braid % VW (7x.006 ) 95% Shield Coverage 6.5Ω/M 84.1Ω/M 27.9Ω/k 275.9Ω/k M17/113-RG AWG Stranded (27x36).030 Tinned Copper 95% Tinned Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket UL AWM 9252 NEC: AWG TC Braid % Style 1354 CMX (27x36) Shield (30V 60 C) CEC: % Shield CMX TC Coverage 17.1Ω/M 5.2Ω/M 56.1Ω/k 17.1Ω/k M17/ (RG-122/U). Non-SWR swept version RG-122. DCR = DC Resistance SCC = Silver-coated Copper = Silver-coated Copper-covered Steel TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown Teflon is a DuPont tradeark. Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3
2 C O A X I A L C A B L E S Oh Coax 20 AWG Stranded (19x33).035 Tinned Copper 95% Tinned Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket 85 C AWG TC Braid % (19x33) 95% Shield.035 Coverage TC 4.1Ω/M 10.8Ω/M 13.4Ω/k 35.4Ω/k M17/28-RG58 Lengths 85 C 8262 U-500 U AWG TC Braid % (19x33) 95% Shield U-1000 U Coverage TC 4.1Ω/M 10.8Ω/M 13.4Ω/k 35.4Ω/k M17/ (RG-58C/U). Non-SWR swept version RG-58. DCR Shielding OD Inch DCR Inch AWG Solid.034 Silver-coated Copper Two Silver-coated Copper Braids (95% Shield Coverage) Polyethylene Insulation Black Non-containating PVC Jacket UL AWM 9273 NEC: AWG (2) SCC % Style 1354 CMX U-500 U (solid) Braids (30V 60 C) CEC: % Shield CMX U-1000 U SCC Coverage Ω/M 2.5Ω/M 28.9Ω/k 8.2Ω/k M17/ (RG-223/U). Non-SWR swept version RG AWG Solid.037 Silver-coated Copper-covered Steel Two Silver-coated Copper Braids (96% Shield Coverage) Plenu TFE Teflon Insulation Tinted Brown FEP Jacket 200 C NEC: AWG (2) SCC % VW-1 CMP (solid) Braids CEC: % Shield CMP FT6 Coverage 19.3Ω/M 2.3Ω/M 63.3Ω/k 7.5Ω/k M17/60-RG C NEC: AWG (2) SCC % VW-1 CMP (solid) Braids CEC: % Shield CMP FT6 Coverage 19.3Ω/M 2.3Ω/M 63.3Ω/k 7.5Ω/k M17/ (RG-142B/U). Non-SWR swept version RG AWG Solid.037 Silver-coated Copper-covered Steel 95% Silver-coated Copper Braid Shield Plenu TFE Teflon Insulation Tinted Brown FEP Jacket 200 C NEC: AWG SCC Braid % VW-1 CL2P (solid) Shield % Shield Coverage 16.3Ω/M 4.3Ω/M 53.5Ω/k 14.1Ω/k M17/111-RG303 DCR = DC Resistance SCC = Silver-coated Copper = Silver-coated Copper-covered Steel TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown. Teflon is a DuPont tradeark Coaxial Cables Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3
3 C O A X I A L C A B L E S Oh Coax 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel Silver-coated Copper Braid Shield TFE Teflon Insulation Tinted Brown FEP Jacket 200 C AWG SCC Braid % VW (7x38) 95% Shield Coverage 8.5Ω/M 28.2Ω/k 801.0Ω/k M17/94-RG179 Lengths DCR Shielding OD Inch DCR Inch AWG Solid.023 Bare Copper-covered Steel 95% Bare Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9204 NEC: AWG BC Braid % VW-1 CMH U-1000 U (solid) 95% Shield CEC: Coverage CMH FT1 BCCS 2.6Ω/M 47.0Ω/M 8.5Ω/k 152.4Ω/k M17/29-RG59 18 AWG Stranded (7x26).048 Tinned Copper 97% Bare Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9212 NEC: AWG BC Braid % VW-1 CMH (7x26) 97% Shield CEC:.048 Coverage CMH FT1 TC 1.2Ω/M 6.1Ω/M 3.9Ω/k 20.0Ω/k M17/6-RG11 18 AWG Stranded (7x26).048 Tinned Copper Two Bare Copper Braid Shield (95% Shield Coverage) Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9850 NEC: AWG (2) BC % VW-1 CMH (7x26) Braids CEC: % Shield CMH FT1 TC Coverage 6.1Ω/M.8Ω/M 20.0Ω/k 2.6Ω/k M17/77-RG216 BC = Bare Copper BCCS = Bare Copper-covered Steel DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown Teflon is a DuPont tradeark. 6 Coaxial Cables Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3
4 C O A X I A L C A B L E S Oh, 95 Oh and 125 Oh Coax 93 Oh 22 AWG Solid.025 Bare Copper-covered Steel 95% Bare Copper Braid Shield Sei-solid Polyethylene Insulation Black Non-containating PVC Jacket UL AWM 9862 NEC: AWG BC Braid % Style 1354 CMX (solid) 95% Shield (30V 60 C) CEC:.025 Coverage CMX BCCS 2.9Ω/M 41.2Ω/M 9.5Ω/k 135.1Ω/k M17/30-RG62 Lengths DCR Shielding OD Inch DCR Inch Oh 22 AWG Solid.025 Bare Copper-covered Steel BC Outer Braid/TC Inner Braid (95% Shield Coverage) Sei-solid Polyethylene Insulation Black Polyethylene Jacket 85 C AWG (2) Braids % (solid) Inner:.025 BC BCCS Outer: 41.2Ω/M TC 135.1Ω/k 95% Shield Coverage 1.5Ω/M M17/90-RG71 4.9Ω/k 95 Oh 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel Silver-coated Copper Braid Shield TFE Teflon Insulation Tinted Brown FEP Jacket 200 C AWG SCC Braid % VW-1 (7x38) 91% Shield.012 Coverage 6.5Ω/M 21.3Ω/k 801.0Ω/k M17/95-RG Oh 22 AWG Solid.025 Bare Copper-covered Steel 97% Bare Copper Braid Shield Sei-solid Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9857 NEC: AWG BC Braid % CMH (solid) 97% Shield CEC:.025 Coverage CMH FT1 BCCS 1.2Ω/M 41.2Ω/M 3.9Ω/k 135.1Ω/k M17/31-RG63 BC = Bare Copper BCCS = Bare Copper-covered Steel DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN Teflon is a DuPont tradeark. Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3
5 C O A X I A L C A B L E S 6.79 Coputer and Instruentation Cable 50 Oh Ethernet Coax Thin Ethernet 20 AWG Stranded (19x32).037 Tinned Copper Duobond II + 93% Tinned Copper Braid Shield Foa Polyethylene Insulation Gray PVC Jacket UL AWM 9907 NEC: AWG Duobond II % Style 1354 CM U-1000 U (19x32) + 93% (30V 60 C) CL TC Braid CEC: TC 5.8Ω/M CM U-2500 U Ω/M 19.0Ω/k Ω/k DEC Plenu Foa FEP Insulation Gray Fluorocopolyer Jacket 150 C NEC: AWG Duobond II % CMP (19x32) + 93% CL2P TC Braid CEC: TC 5.8Ω/M CMP FT6 8.8Ω/M 19.0Ω/k 28.9Ω/k RG-58/U DEC Plenu Foa FEP Insulation Natural Flaarrest Jacket 75 C NEC: AWG Duobond II % CMP U-1000 U (19x32) + 93% CL2P TC Braid CEC: TC 5.8Ω/M CMP FT6 8.8Ω/M 19.0Ω/k 28.9Ω/k RG-58/U Lengths DCR Shielding OD Inch DCR Inch For Plenu versions 9907, see or Thick Ethernet 12 AWG Solid.086 Bare Copper Duobond IV* Quad Shield Foa Polyethylene Insulation Yellow PVC Jacket UL AWM 9880 NEC: AWG Duobond IV % Style 1478 CL (solid) (Duobond II (30V 60 C) CM % TC Braid CEC: BC + Duoil CM 1.4Ω/M + 90% TC For Plenu version 9880, 4.7Ω/k Braid) 1.5Ω/M see DEC Ω/k Ring-band stripes arked every 2.5 eters to aid users in tap placeent. Plenu Foa FEP Insulation Orange Fluorocopolyer Jacket 150 C NEC: AWG Duobond IV % CL2P (solid) (Duobond II CMP % TC Braid CEC: BC + Duoil CMP FT6 1.4Ω/M + 90% TC 4.7Ω/k Braid) DEC Ω/M Ring-band stripes arked every 2.5 eters to aid users in tap placeent. 5.0Ω/k Suitable for Outdoor and Direct Burial applications. BC = Bare Copper DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. For cable anufactured to latest governent revision or other MIL-SPEC requireents, please contact your nearest Belden Regional Sales Office. *Duobond IV = Duobond II + 94% tinned copper braid + Duoil + 90% tinned copper braid. (Plenu version is Duobond II + 90% tinned copper braid + Duoil + 90% tinned copper braid.) Spools and/or UnReel cartons are one piece, but length ay vary ±10% fro length shown Coaxial Cables Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3
6 C O A X I A L C A B L E S 6.80 Coputer and Instruentation Cable 75 Oh Coax 75 Oh 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel 95% Silver-coated Copper Braid Shield TFE Teflon Insulation White TFE Tape Jacket 200 C AWG SCC Braid % VW (7x38) 95% Shield.012 Coverage 8.6Ω/M 28.2Ω/k 801.0Ω/k RG-187A/U MIL-C-17D Lengths DCR Shielding OD Inch DCR Inch Oh Dual RG-59/U 23 AWG Solid.023 Bare Copper-covered Steel Bare Copper Braid Shield Flae-retardant Sei-foa Polyethylene Insulation Black PVC Jacket UL AWM 9555 NEC: AWG BC Braid % Style CM (solid) 95% Shield x x (300V 80 C) CEC: Coverage CM BCCS 2.6Ω/M Plenu FEP Insulation Clear FEP Jacket 50.0Ω/M 164.0Ω/k 8.5Ω/k 200 C NEC: AWG BC Braid % CMP (solid) 97% Shield x x CEC:.023 Coverage CMP FT6 BCCS 2.6Ω/M 50.0Ω/M 8.5Ω/k 164.0Ω/k Suitable for Outdoor and Direct Burial applications. 75 Oh RG-6/U 18 AWG Solid Bare Copper-covered Steel Duobond IV* Quad Shield Non-Plenu Foa Polyethylene Insulation Gray PVC Jacket 3131A NEC: AWG Duobond IV % CL2R, (solid) Quad Shield CMR Ω/M Steel CEC: Bare Copper 11.8Ω/k CMR FT4 Covered Sweep tested 5 to 400. CPE jacket optional. 28.0Ω/M 91.8Ω/k Plenu Foa FEP Insulation Gray Fluorocopolyer Jacket For Plenu version 9555, see C 3132A NEC: AWG Duobond IV % CMP, (solid) Quad Shield PLTC Ω/M CEC: Bare Copper 11.8Ω/k CMP FT6 Covered Steel Sweep tested 5 to Ω/M 19.8Ω/k Suitable for Outdoor and Direct Burial applications Oh RG-11/U 14 AWG Solid Bare Copper-covered Steel Duobond IV* Quad Shield Non-Plenu Foa Polyethylene Insulation Gray PVC Jacket 3094A NEC: AWG Duobond IV % CL2R, (solid) Quad Shield CMR Ω/M CEC: BCCS 5.9Ω/k Sweep tested 5 to 400. CMR FT4 11.0Ω/M 36.1Ω/k CPE jacket optional. Ring-band stripes arked every 2.6 eters to aid users in tap placeent. BC = Bare Copper BCCS = Bare Copper-covered Steel DCR = DC Resistance SCC = Silver-coated Copper = Silver-coated Copper-covered Steel Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown. Spools and/or UnReel cartons are one piece, but length ay vary ±10% fro length shown. * Duobond IV Quad Shield = Duobond + 60% aluinu braid + Duoil + 40% aluinu braid Teflon is a DuPont tradeark. Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3
7 C O A X I A L C A B L E S 6.86 Coputer and Instruentation Cable 50 Oh Triax Lengths RG-58A/U 20 AWG Stranded (7x28).037 Tinned Copper Two Tinned Copper Braids (96% Shield Coverage) Polyethylene Insulation Yellow PVC Jacket (Polyethylene Insulation between Braids) DCR 75 C AWG (2) TC Braids % U-500 U (7x28) 96% Shield Coverage TC Inner: 9.5Ω/M 31.0Ω/k Shielding OD Inch DCR Inch 4.7Ω/M 15.5Ω/k Outer: 4.3Ω/M 14.1Ω/k RG-8/U 11 AWG Stranded (7x19).108 Bare Copper Two Bare Copper Braids (96% Shield Coverage) Foa Polyethylene Insulation Black Polyethylene Jacket (Polyethylene Insulation between Braids) 80 C AWG (2) BC % (7x19) 96% Shield.108 Coverage BC Inner: 1.2Ω/M 3.9Ω/k BC = Bare Copper DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN Ω/M 3.9Ω/k Outer: 2.1Ω/M 4.9Ω/k Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3
SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)
SECTION 260523 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less) PART 1 - GENERAL 1.1 SUMMARY A. Related Documents: 1. Drawings and general provisions of the Subcontract apply
More informationAUDIO & VIDEO CABLES
AUDIO & VIDEO CABLES Speaker Wire AUDIO & VIDEO CABLES 2 Conductor 4 Conductor Commercial Grades Heavy Duty and Professional Grades Home Theater Oxygen Free Outdoor Audio Direct Burial Grades 10 AWG including
More informationInside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR
Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning
More informationTechnical Bulletin #27 Wiring for Architectural Applications
400, du Parc, Saint-Eustache, Québec Canada, J7R 0A1 Tel: +1.450.491.5671 +1.800.665.1166 Fax: +1.450.491.3788 www.heicolighting.com Technical Bulletin #27 Wiring for Architectural Applications WIRE SIZE
More informationSECTION INSULATED WIRE AND CABLE
SECTION 16120 INSULATED WIRE AND CABLE PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Insulated Wire and Cable, which includes the following items with accessories, and appurtenances:
More information600 VOLT 600V, 3 CONDUCTOR (WITH GROUND), FR-EPR OR FR-XLPE INSULATION, PVC JACKET SPECIFICATIONS (FLAME RETARDANT POWER CABLE) (UL TYPE TC-ER) TYPE C3 SPEC 70.0100 PROJECT 196116 REFERENCE: LATEST EDITIONS
More informationCable solutions for Automation & Drives
www.leoni-industrial-solutions.com Cable solutions for Automation & Drives The Quality Connection Issue 11/2016 All FieldLink products are permanently enhanced for our customers. Therefore this brochure
More informationQualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder
Qualification Reference: 15404201.AA/1-20-2015 Cage Code: 67050 MIL-C-27500 Cables NEMA WC27500 Part Number Builder MIL-C-27500 Cables NEMA WC 27500 Part Number Builder MIL-C-27500 (M27500 Cable) MIL Spec
More information3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series
M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 659 Series Round construction permits easier routing 28 AWG wire on.050 inch pitch permits mass termination to broad
More informationConductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.
37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),
More informationUna e mpre sa Vi akab l e GLOSSARY.
GLOSSARY www.centelsa.com.co CONDUCTORS Cu Copper conductors. CuSn Tinned copper conductor. ACDSR Rectangular soft bare copper wire. ACDSRP Paper insulated rectangular soft bare copper wire. ACDD Bare
More informationSECTION GROUNDING AND BONDING
SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and
More informationThermocouple Wire and Cable Insulation THERMOCOUPLE AND EXTENSION GRADE WIRE Type J
Thermocouple Wire and Cable Insulation THERMOCOUPLE AND EXTENSION GRADE WIRE Type J This Section Contains Insulation Reference Tables Thermocouple Wire Extension Grade Wire Bare Wire Multipair Cable General
More informationConstruction guideline
1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:
More information*** Supercedes: BECO E and COM , , & ***
7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single
More informationOutdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection
1Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support Datasheet Protect your networks
More informationDESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7
DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification
More informationMIL-W wire. Construction characteristics MIL-W wires. MIL-W part numbering and example
MIL-W-16878 wire MIL-W-16878 (NEMA HP3, HP4) wires are general-purpose, medium and high-temperature hookup wires, with PTFE or FEP insulation. Each insulation type is available in thin, medium, or heavy
More informationPRODUCT SELECTION LOCATOR
PRODUCT SELECTION LOCATOR SECTION SPECIFICATION 1 300V Instrumentation Cables 1000 2 600V Instrumentation Cables 2000 3 600V Flexible Control and Power Cables 3000 4 600V Multi Conductor Control and Power
More informationFP30112WHITE100 Heat Shrink TW Tubing 100' Spool
FP30112WHITE100 Heat Shrink TW Tubing Minnesota Mining (3M) Catalog Number FP30112WHITE100 Manufacturer Minnesota Mining (3M) Description Tubing, Heat; ; 600 V; Cable Size 1/2 Inch; Thin Wall; Shrink Temperature
More informationCeramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code
Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641
More informationAmerica s Wire Company
America s Wire Company Dear Customer, We re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of products
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead
Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat
More informationWHITE PAPER Flex Life vs Flexibility
WHITE PAPER Flex Life vs Flexibility The design criteria for both flex life and flexibility is the same but the properties and application of the elements can be vastly different. The design elements are
More informationThis product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.
Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral
More informationDatasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths
Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This
More informationSingle core conductor BETAtherm 145
Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with
More informationSpecifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)
ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or
More informationSECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.
SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:
More informationENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)
ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,
More informationStandard of Practice - Campus Electrical Distribution System
A26.3 Standard of Practice - Campus Electrical Distribution System NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all
More informationSection ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR
PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated
More informationIntroduction. Cable Assembly Solutions
Introduction Cable Assembly Solutions Epec Engineered Technologies is a highly regarded supplier of cable assemblies used in a wide variety of markets including Medical, Industrial, Automotive, and Data
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the
More informationDETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE SPECIAL PURPOSE, ELECTRICAL SHIELDED AND UNSHIELDED, GENERAL SPECIFICATION FOR
INCH-POUND 10 December 1997 SUPERSEDING MIL-C-27500G 23 FEB. 1990 DETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE SPECIAL PURPOSE, ELECTRICAL SHIELDED AND UNSHIELDED, GENERAL SPECIFICATION FOR
More informationIEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor
TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification
More informationFINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING
PRICE LIST NO: FCL/IW.11.17/05 HSN CODE:85 FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL CABLES WITH FLAME RETARDANT PROPERTIES &
More informationA LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING
A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING EMI Shielding ARACON fibers braided into a shield or sock offer superior performance against electromagnetic interference. Advantages include: More uniform
More informationMineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths
Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable
More informationHeritage Quality Performance
FEP FEATURES AND PROPERTIES Heritage Quality Performance Extruded, FEP insulated, high voltage wire and cable offers exceptional dielectric strength without the disadvantages common to equally rated silicone
More informationPhone: Fax:
SEPTEMBER 2007 www.nsiindustries.com Phone: 800.321.5847 Fax: 800.841.5566 Mechanical Connectors Dual Rated Single & Double Lugs........................ 1 Panelboard Lugs............................ 1
More informationEngineering Data for Copper and Aluminum Conductor Electrical Cables
2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION
More information3M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 3476 Series
M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 476 Series 28 AWG wire on.050 inch centers permits mass termination to a broad line of IDC connectors Ground plane construction for increased signal
More informationHeat-Shrinkable Tubing
CPO 2:1 Shrink Ratio Thin-Wall Tubing, Non-Lined Flame-retardant, cross-linked polyolefin Continuous operating temperature: -55 C to 135 C Shrink temperature of 120 C Meets UL and CSA standards; MIL-DTL-23053/5
More informationPILC Replacement: Getting the Lead Out
PILC Replacement: Getting the Lead Out Spring Cincinnati, OH April 30, 2003 Page 1 PILC IS GREAT! Low Profile High Fault Current Capability on Shield High Degree of Water Blocking So why shouldn t you
More informationShrink-Kon Thin Wall Heat Shrinkable Tubing
Shrink Ratio 2:1 Shrink-Kon Thin Wall Tubing Styles 2:1 Shrink Ratio, Non-Lined Flame retardant. Resistant to common fluids and solvents. Meets UL 224, 125 C; CSA C22.2 No. 198.1, 125 C; MIL-DTL-23053/5
More informationExperience and a History in Construction Products
BDI1004-Brochure 12/14/06 8:41 AM Page 2 Experience and a History in Construction Products Accessory Products. Although Blue Diamond Industries was established in 2004, the management team has experience
More informationLMR-400. LMR -400 Flexible Low Loss Communications Coax TIMES MICROWAVE SYSTEMS
LMR-400 LMR -400 Flexible Low Loss Communications Coax Ideal for Drop-in replacement for RG-8/9913 Air-Dielectric type Cable Jumper Assemblies in Wireless Communications Systems Short Antenna Feeder runs
More informationThe Hirschmann TM by Belden Brand Industrial Ethernet Media Solutions
A BELDEN BRAND The Hirschmann TM by Belden Brand Industrial Ethernet Media Solutions Industrial Ethernet Cordsets 2 and 4 Pair PVC, TPE and TPE High Flex with Bonded Pairs Stranded and The Hirschmann Brand
More informationElectrical Conductors
Electrical Conductors Course No: E02-005 Credit: 2 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com
More informationMEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]
[6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are
More informationCONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6
CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................
More informationEvaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire
Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire Today s Topics Brief Overview of Southwire In-depth Discussion on Aluminum Characteristics Discussion of
More informationGlossary Of Terms M-1
Glossary Of Terms ANSI - American National Standards Institute. Armor - A sheath, serving, braid or other layer of metal applied over a cable to increase its mechanical protection. ARR - Association of
More information3M Electromagnetic Compatible Products
3M Electromagnetic Compatible Products Selection Guide Revision E 3 Innovation Faster, smaller, lighter, easier the skyrocketing development of today s electronics requires new solutions for significant
More informationWelding Accessories
Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent
More informationTechnical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE
Excerpt from PYSMIAN S WIE AND CABLE ENGINEEING GUIDE Page 1 of 9 Areas and diameters of solid and concentric stranded conductors Conductor Size (AWG or kcmil) Area (cma) Solid Wire (mils) weight (lbs/1000
More informationDetailed Specifications & Technical Data
For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 4 to 36 optical fibers, Gel filling loose tubes
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-26 05 19.10 10 (May 2016) ----------------------------------- Preparing Activity: USACE Superseding UFGS-26 05 19.00 10 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationwelding Coleman Cable Inc. is a worldwide leader in the
PRODUCTS Introduction Welding Cable Applications NEC Article 630 electric welders Electrode holder & clamp connections to arc welder, bus, welding box or transformer Permanent or temporary lighting Battery
More informationSingle-Jacketed Tubing
Single-Jacketed Tubing COILED STICK CUT TO LENGTH UTC Single Jacketed tube Protect the tube against corrosion and pitting in a diverse changing environment and climates. The phenomenon of Chloride Stress
More informationACT. Summary. 1 Introduction. 2 Synoptic. 3 Technical characteristics. 4 Part-numbering system. 5 Arrangements. 6 Receptacles. 7 Plug / Panel seal
Summary 1 Introduction 2 Synoptic 3 Technical characteristics 4 Part-numbering system 5 Arrangements 6 Receptacles 7 Plug / Panel seal 8 Mating and unmating dimensions 9 Mounting cutouts 10-11 Contacts
More informationSTANDARD COAXIAL CONNECTORS
STANDARD COAXIAL CONNECTORS COAXI-KIT ISO 9001 APPROVED RADIALL COMPANY PROFILE Since 1952, RADIALL has specialized in the field of coaxial connectors and cables assemblies. RADIALL s experience and high
More informationBASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola
BASIC CONCEPTS IN ELECTRICAL DESIGN Prepared by Engr. John Paul Timola ELECTRICAL CONDUCTORS AND INSULATORS Electrical Conductors substances that offer a very low resistance to current flow. Insulators
More informationFLEXIBLE CONDUITS AND CONNECTORS
FLEXIBLE CONDUITS AND CONNECTORS Use the best Use ANAMET! Anamet is a global company with plants in Canada, the United States and Europe. Anamet has manufactured product for the Canadian electrical industry
More informationMechanical Insulation for Refrigeration Systems
Mechanical Insulation for Refrigeration Systems INDUSTRIAL REFRIGERATION CONSORTIUM RESEARCH & TECHNOLOGY FORUM MAY 2-3, 2012 Peter Gauchel, President/CEO L&C Insulation Inc. Overview Current trends in
More informationThe University of Texas at Austin September 30, 2011
SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATIONS PART 1 - GENERAL 1.1 SUMMARY A. This section governs the products and execution requirements relating to furnishing and installing grounding and
More information15 Pin DSUB - MALE 15 Pin DSUB - FEMALE 9 Pin DSUB - MALE 9 Pin DSUB - FEMALE
Last Revised: 6 Oct 07 Description: This data sheet show our range of high quality appliance cables, such as signal cables (VGA / DVI / DisplayPort (DP)), Touchscreen and power cables. These are either
More informationYour Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified
Your Partner for Custom Interconnectivity Solutions ISO 9001 AS9100C ISO 13485 ISO 17025 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven Decades of Expertise
More informationPANDUIT 4-PAIR COPPER DATA CABLE RISER RATED
ENVIRONMENTAL PRODUCT DECLARATION PANDUIT 4-PAIR COPPER DATA CABLE RISER RATED At Panduit, we re serious about sustainability. Everyone s talking about sustainability these days. Companies are making huge
More informationInternational Thermocouple and Extension Grade Wire Color Codes
International Thermocouple and Extension Grade Wire Color Codes ANSI Code Alloy Combination + Lead - Lead Color Coding Thermocouple Extension Grade Grade Maximum Useful Range ++ Maximum Thermocouple Grade
More informationStainless Steel Series MIL-DTL Series III
8D - D38999 Stainless Steel Series Stainless Steel Series MIL-DTL-38999 Series III 39 8D Series - MIL-DTL-38999 Series III Description High contact density Screw coupling Contact protection: 100% Scoop
More informationSECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION)
SECTION 271400 BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION) These specifications guidelines detail the intents of KCTCS for Telecommunications Infrastructure Design and Installation.
More informationIDEAL / ARTOS MACHINE SERIES
IDEAL / ARTOS MACHINE SERIES THIS SECTION CONTAINS BLADES FOR THE FOLLOWING MACHINE SERIES: 45-048 45-725 45-064 45-774 45-065 45-940 45-700 / 45-705 Your Global Source for Wire Processing Perishable Tooling
More information15 kv EPR Insulated, Jacketed, URD Cable
15 kv EPR Insulated, Jacketed, URD Cable 1000 kcm Copper Conductor with Tape Shield Page 1 of 11 Table Of Contents 1 GENERAL... 3 2 STANDARDS... 3 3 APPROVED CABLE MANUFACTURERS... 3 4 REEL SPECIFICATIONS...
More informationSPECIFICATIONS: If your preferred product configuration is not shown, please contact our sales representative for custom design.
NEW! Series TK SPECIFICATIONS: CONTACT RATING: 200mA / 1.5A @ 5~30VDC. ELECTRICAL LIFE: 1 million cycles at full load. CONTACT RESISTANCE: 20m-ohms max. INSULATION RESISTANCE: 600VDC 10M-ohms min. ESD
More information2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING
2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending
More informationUnderground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11
Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available
More informationTHERMOFIT ADHESIVE S Flex Fluid Resistant, High Temperature, One Part-Flexible Epoxy
TE Connectivity 30 Constitution Drive Menlo Park, CA 9402 USA SPECIFICATION THIS ISSUE: DATE: REPLACES: RT-1014 ISSUE 4 April 19, 2016 Issue 3 1. SCOPE THERMOFIT ADHESIVE S-12-04 Flex Fluid Resistant,
More informationThermocouples and Accessories Product Catalog
Thermocouples and Accessories Product Catalog 7282 N. Haggerty Rd. Canton, MI 48187 P. 734-451-8740 / F. 734-451-8741 www.inspec-inc.com 1 P a g e EXPERT CONTROL AND INSTRUMENTATION REPAIR Plastics Industry
More informationCATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG. CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF
CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF 1 Solutions That Work Eastern Wire + Conduit products provide high quality
More informationetwork etwork-/ethernet-/foc-cable
etwork etwork-/ethernet-/foc-cable Chainflex eadycable Network-/Ethernet-/FOC-cable Cable type Jacket Page CFLG.6G Gradient fiber glass cable TPE 226 CFLG.12G Gradient fiber glass cable TPE 228 CAT5 Ethernet
More informationWIRING PROTECTOR. Edge holder EH-1 series 72 EHS/EHP series 73 LT series 74. Free bush SG series 75. EL free bush EL series 75. Grommet ESG series 76
W I R I N G A C C E S S O R Y 70 Edge holder EH-1 series 72 EHS/EHP series 73 LT series 74 Free bush SG series 75 EL free bush EL series 75 Grommet ESG series 76 Edging EE/EO series 76 Spiral tubing SS
More informationSECTION P -- CABLE VAULT AND CABLE ENTRANCE FACILITY
INSTLLTION REQUIREMENTS Section P, TT-TP-76300 T&T January 2012 Revised July, 2012 SECTION P -- CLE VULT ND CLE ENTRNCE FCILITY CONTENTS PGE 1. GENERL... P-1 1.1. Introduction... P-1 1.2. Non-Insulating
More informationIndustrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable
Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional
More informationServ. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution
Serv Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution General Cable offers a complete line of insulated cable designs and sizes to meet utility requirements for exceptional
More information8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.
2012 Edition Redbook 8.0 REVENUE METERING 8.1 INTRODUCTION The purpose of this section is to outline requirements of the Customer, as set forth herein by LIPA, as they pertain to Electric Revenue Metering
More informationTitle: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards
Change History Date Description of Change Pages / Sections Modified Change Approver Initials 6/15/16 Updated division section from 16124 to 2605 - mgl44 13, removed references to other section 10/17/14
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 15 2006 (Formerly IPS SP 100) Specification for Trunk, Feeder and Distribution Coaxial Cable NOTICE The Society
More information750 N A 100 M P
onduit Assemblies Legacy Adapter to Adapter Series 72 & 74 Tubing & Series 75 onduit or use with adapters and transitions shown in Table III OR AAPTR-TO-AAPTR APPLIATIONS Product Series 750 = Series 75
More informationDETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU
INCH-POUND MIL-DTL-24643/17F 1 October 2009 SUPERSEDING MIL-DTL-24643/17E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU This specification is approved
More informationTYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.
To: National Cables Industry P.O Box 27472 Al Dhaid Road, Al Sajja Industrial Area Sharjah U.A.E TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE Kinectrics International Inc. Report No.: K-422341-RC-0001-R00
More informationUNDERGROUND SERVICES SECONDARY
Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-
More informationTable of Contents. Applications...3 Medical...4 Industrial...5
Table of Contents Applications...3 Medical...4 Industrial...5 Extruded Sizes...7 PTFE Sub-Lite-Wall Extruded&HeatShrinkableTubing...8 ExtrudedTubing(AWG)...10 HeavyConstructionTubing...14 HeavyWallTubing...15
More information80M 4-Square. An antenna project to obtain a bigger signal on the 80 Meter (3.5 to 3.8 MHz) amateur radio band. Bruce Whitney W8RA
An antenna project to obtain a bigger signal on the 80 Meter (3.5 to 3.8 MHz) amateur radio band Bruce Whitney W8RA The Goal: Convert a vacant back field into 4.2 db of power (directional) gain Switchable
More informationThe Company by Peter Bröckskes sen. an independent, middle sized company
The Company DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff
More informationA. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).
16450 GROUNDING ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 26 An optional keynote to the
More informationTable of Contents. Applications...3. Extruded Sizes...7. Value Added Services Heat Shrinkable Extrusions Technical Information...
Table of Contents Applications...3 Medical...4 Industrial...5 Extruded Sizes...7 PTFE Sub-Lite-Wall Extruded&HeatShrinkableTubing...8 ExtrudedTubing(AWG)...10 HeavyConstructionTubing...14 HeavyWallTubing...15
More informationEvolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.
Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical
More information