Nominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR

Size: px
Start display at page:

Download "Nominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR"

Transcription

1 C O A X I A L C A B L E S Oh Coax Lengths 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel Silver-coated Copper Braid Shield TFE Teflon Insulation White FEP Jacket 200 C AWG SCC Braid % VW (7x38) 96% Shield Coverage 14.6Ω/M 47.9Ω/k 801.0Ω/k M17/ (RG-178B/U). Non-SWR swept version RG-178. DCR Shielding OD Inch DCR Inch AWG Stranded (7x.006 ).020 Silver-coated Copper-covered Steel 95% Silver-coated Copper Braid Shield TFE Teflon Insulation White FEP Jacket 200 C AWG SCC Braid % VW (7x.006 ) 95% Shield Coverage 6.5Ω/M 84.1Ω/M 27.9Ω/k 275.9Ω/k M17/ (RG-316/U). Non-SWR swept version RG-316. TFE Teflon Insulation Brown FEP Jacket 200 C AWG SCC Braid % VW (7x.006 ) 95% Shield Coverage 6.5Ω/M 84.1Ω/M 27.9Ω/k 275.9Ω/k M17/113-RG AWG Stranded (27x36).030 Tinned Copper 95% Tinned Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket UL AWM 9252 NEC: AWG TC Braid % Style 1354 CMX (27x36) Shield (30V 60 C) CEC: % Shield CMX TC Coverage 17.1Ω/M 5.2Ω/M 56.1Ω/k 17.1Ω/k M17/ (RG-122/U). Non-SWR swept version RG-122. DCR = DC Resistance SCC = Silver-coated Copper = Silver-coated Copper-covered Steel TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown Teflon is a DuPont tradeark. Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3

2 C O A X I A L C A B L E S Oh Coax 20 AWG Stranded (19x33).035 Tinned Copper 95% Tinned Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket 85 C AWG TC Braid % (19x33) 95% Shield.035 Coverage TC 4.1Ω/M 10.8Ω/M 13.4Ω/k 35.4Ω/k M17/28-RG58 Lengths 85 C 8262 U-500 U AWG TC Braid % (19x33) 95% Shield U-1000 U Coverage TC 4.1Ω/M 10.8Ω/M 13.4Ω/k 35.4Ω/k M17/ (RG-58C/U). Non-SWR swept version RG-58. DCR Shielding OD Inch DCR Inch AWG Solid.034 Silver-coated Copper Two Silver-coated Copper Braids (95% Shield Coverage) Polyethylene Insulation Black Non-containating PVC Jacket UL AWM 9273 NEC: AWG (2) SCC % Style 1354 CMX U-500 U (solid) Braids (30V 60 C) CEC: % Shield CMX U-1000 U SCC Coverage Ω/M 2.5Ω/M 28.9Ω/k 8.2Ω/k M17/ (RG-223/U). Non-SWR swept version RG AWG Solid.037 Silver-coated Copper-covered Steel Two Silver-coated Copper Braids (96% Shield Coverage) Plenu TFE Teflon Insulation Tinted Brown FEP Jacket 200 C NEC: AWG (2) SCC % VW-1 CMP (solid) Braids CEC: % Shield CMP FT6 Coverage 19.3Ω/M 2.3Ω/M 63.3Ω/k 7.5Ω/k M17/60-RG C NEC: AWG (2) SCC % VW-1 CMP (solid) Braids CEC: % Shield CMP FT6 Coverage 19.3Ω/M 2.3Ω/M 63.3Ω/k 7.5Ω/k M17/ (RG-142B/U). Non-SWR swept version RG AWG Solid.037 Silver-coated Copper-covered Steel 95% Silver-coated Copper Braid Shield Plenu TFE Teflon Insulation Tinted Brown FEP Jacket 200 C NEC: AWG SCC Braid % VW-1 CL2P (solid) Shield % Shield Coverage 16.3Ω/M 4.3Ω/M 53.5Ω/k 14.1Ω/k M17/111-RG303 DCR = DC Resistance SCC = Silver-coated Copper = Silver-coated Copper-covered Steel TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown. Teflon is a DuPont tradeark Coaxial Cables Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3

3 C O A X I A L C A B L E S Oh Coax 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel Silver-coated Copper Braid Shield TFE Teflon Insulation Tinted Brown FEP Jacket 200 C AWG SCC Braid % VW (7x38) 95% Shield Coverage 8.5Ω/M 28.2Ω/k 801.0Ω/k M17/94-RG179 Lengths DCR Shielding OD Inch DCR Inch AWG Solid.023 Bare Copper-covered Steel 95% Bare Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9204 NEC: AWG BC Braid % VW-1 CMH U-1000 U (solid) 95% Shield CEC: Coverage CMH FT1 BCCS 2.6Ω/M 47.0Ω/M 8.5Ω/k 152.4Ω/k M17/29-RG59 18 AWG Stranded (7x26).048 Tinned Copper 97% Bare Copper Braid Shield Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9212 NEC: AWG BC Braid % VW-1 CMH (7x26) 97% Shield CEC:.048 Coverage CMH FT1 TC 1.2Ω/M 6.1Ω/M 3.9Ω/k 20.0Ω/k M17/6-RG11 18 AWG Stranded (7x26).048 Tinned Copper Two Bare Copper Braid Shield (95% Shield Coverage) Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9850 NEC: AWG (2) BC % VW-1 CMH (7x26) Braids CEC: % Shield CMH FT1 TC Coverage 6.1Ω/M.8Ω/M 20.0Ω/k 2.6Ω/k M17/77-RG216 BC = Bare Copper BCCS = Bare Copper-covered Steel DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown Teflon is a DuPont tradeark. 6 Coaxial Cables Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3

4 C O A X I A L C A B L E S Oh, 95 Oh and 125 Oh Coax 93 Oh 22 AWG Solid.025 Bare Copper-covered Steel 95% Bare Copper Braid Shield Sei-solid Polyethylene Insulation Black Non-containating PVC Jacket UL AWM 9862 NEC: AWG BC Braid % Style 1354 CMX (solid) 95% Shield (30V 60 C) CEC:.025 Coverage CMX BCCS 2.9Ω/M 41.2Ω/M 9.5Ω/k 135.1Ω/k M17/30-RG62 Lengths DCR Shielding OD Inch DCR Inch Oh 22 AWG Solid.025 Bare Copper-covered Steel BC Outer Braid/TC Inner Braid (95% Shield Coverage) Sei-solid Polyethylene Insulation Black Polyethylene Jacket 85 C AWG (2) Braids % (solid) Inner:.025 BC BCCS Outer: 41.2Ω/M TC 135.1Ω/k 95% Shield Coverage 1.5Ω/M M17/90-RG71 4.9Ω/k 95 Oh 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel Silver-coated Copper Braid Shield TFE Teflon Insulation Tinted Brown FEP Jacket 200 C AWG SCC Braid % VW-1 (7x38) 91% Shield.012 Coverage 6.5Ω/M 21.3Ω/k 801.0Ω/k M17/95-RG Oh 22 AWG Solid.025 Bare Copper-covered Steel 97% Bare Copper Braid Shield Sei-solid Polyethylene Insulation Black Non-containating PVC Jacket 60 C 9857 NEC: AWG BC Braid % CMH (solid) 97% Shield CEC:.025 Coverage CMH FT1 BCCS 1.2Ω/M 41.2Ω/M 3.9Ω/k 135.1Ω/k M17/31-RG63 BC = Bare Copper BCCS = Bare Copper-covered Steel DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN Teflon is a DuPont tradeark. Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3

5 C O A X I A L C A B L E S 6.79 Coputer and Instruentation Cable 50 Oh Ethernet Coax Thin Ethernet 20 AWG Stranded (19x32).037 Tinned Copper Duobond II + 93% Tinned Copper Braid Shield Foa Polyethylene Insulation Gray PVC Jacket UL AWM 9907 NEC: AWG Duobond II % Style 1354 CM U-1000 U (19x32) + 93% (30V 60 C) CL TC Braid CEC: TC 5.8Ω/M CM U-2500 U Ω/M 19.0Ω/k Ω/k DEC Plenu Foa FEP Insulation Gray Fluorocopolyer Jacket 150 C NEC: AWG Duobond II % CMP (19x32) + 93% CL2P TC Braid CEC: TC 5.8Ω/M CMP FT6 8.8Ω/M 19.0Ω/k 28.9Ω/k RG-58/U DEC Plenu Foa FEP Insulation Natural Flaarrest Jacket 75 C NEC: AWG Duobond II % CMP U-1000 U (19x32) + 93% CL2P TC Braid CEC: TC 5.8Ω/M CMP FT6 8.8Ω/M 19.0Ω/k 28.9Ω/k RG-58/U Lengths DCR Shielding OD Inch DCR Inch For Plenu versions 9907, see or Thick Ethernet 12 AWG Solid.086 Bare Copper Duobond IV* Quad Shield Foa Polyethylene Insulation Yellow PVC Jacket UL AWM 9880 NEC: AWG Duobond IV % Style 1478 CL (solid) (Duobond II (30V 60 C) CM % TC Braid CEC: BC + Duoil CM 1.4Ω/M + 90% TC For Plenu version 9880, 4.7Ω/k Braid) 1.5Ω/M see DEC Ω/k Ring-band stripes arked every 2.5 eters to aid users in tap placeent. Plenu Foa FEP Insulation Orange Fluorocopolyer Jacket 150 C NEC: AWG Duobond IV % CL2P (solid) (Duobond II CMP % TC Braid CEC: BC + Duoil CMP FT6 1.4Ω/M + 90% TC 4.7Ω/k Braid) DEC Ω/M Ring-band stripes arked every 2.5 eters to aid users in tap placeent. 5.0Ω/k Suitable for Outdoor and Direct Burial applications. BC = Bare Copper DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. For cable anufactured to latest governent revision or other MIL-SPEC requireents, please contact your nearest Belden Regional Sales Office. *Duobond IV = Duobond II + 94% tinned copper braid + Duoil + 90% tinned copper braid. (Plenu version is Duobond II + 90% tinned copper braid + Duoil + 90% tinned copper braid.) Spools and/or UnReel cartons are one piece, but length ay vary ±10% fro length shown Coaxial Cables Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3

6 C O A X I A L C A B L E S 6.80 Coputer and Instruentation Cable 75 Oh Coax 75 Oh 30 AWG Stranded (7x38).012 Silver-coated Copper-covered Steel 95% Silver-coated Copper Braid Shield TFE Teflon Insulation White TFE Tape Jacket 200 C AWG SCC Braid % VW (7x38) 95% Shield.012 Coverage 8.6Ω/M 28.2Ω/k 801.0Ω/k RG-187A/U MIL-C-17D Lengths DCR Shielding OD Inch DCR Inch Oh Dual RG-59/U 23 AWG Solid.023 Bare Copper-covered Steel Bare Copper Braid Shield Flae-retardant Sei-foa Polyethylene Insulation Black PVC Jacket UL AWM 9555 NEC: AWG BC Braid % Style CM (solid) 95% Shield x x (300V 80 C) CEC: Coverage CM BCCS 2.6Ω/M Plenu FEP Insulation Clear FEP Jacket 50.0Ω/M 164.0Ω/k 8.5Ω/k 200 C NEC: AWG BC Braid % CMP (solid) 97% Shield x x CEC:.023 Coverage CMP FT6 BCCS 2.6Ω/M 50.0Ω/M 8.5Ω/k 164.0Ω/k Suitable for Outdoor and Direct Burial applications. 75 Oh RG-6/U 18 AWG Solid Bare Copper-covered Steel Duobond IV* Quad Shield Non-Plenu Foa Polyethylene Insulation Gray PVC Jacket 3131A NEC: AWG Duobond IV % CL2R, (solid) Quad Shield CMR Ω/M Steel CEC: Bare Copper 11.8Ω/k CMR FT4 Covered Sweep tested 5 to 400. CPE jacket optional. 28.0Ω/M 91.8Ω/k Plenu Foa FEP Insulation Gray Fluorocopolyer Jacket For Plenu version 9555, see C 3132A NEC: AWG Duobond IV % CMP, (solid) Quad Shield PLTC Ω/M CEC: Bare Copper 11.8Ω/k CMP FT6 Covered Steel Sweep tested 5 to Ω/M 19.8Ω/k Suitable for Outdoor and Direct Burial applications Oh RG-11/U 14 AWG Solid Bare Copper-covered Steel Duobond IV* Quad Shield Non-Plenu Foa Polyethylene Insulation Gray PVC Jacket 3094A NEC: AWG Duobond IV % CL2R, (solid) Quad Shield CMR Ω/M CEC: BCCS 5.9Ω/k Sweep tested 5 to 400. CMR FT4 11.0Ω/M 36.1Ω/k CPE jacket optional. Ring-band stripes arked every 2.6 eters to aid users in tap placeent. BC = Bare Copper BCCS = Bare Copper-covered Steel DCR = DC Resistance SCC = Silver-coated Copper = Silver-coated Copper-covered Steel Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN-1. Spools ay contain ore than one piece. Length ay vary ±10% fro length shown. Spools and/or UnReel cartons are one piece, but length ay vary ±10% fro length shown. * Duobond IV Quad Shield = Duobond + 60% aluinu braid + Duoil + 40% aluinu braid Teflon is a DuPont tradeark. Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3

7 C O A X I A L C A B L E S 6.86 Coputer and Instruentation Cable 50 Oh Triax Lengths RG-58A/U 20 AWG Stranded (7x28).037 Tinned Copper Two Tinned Copper Braids (96% Shield Coverage) Polyethylene Insulation Yellow PVC Jacket (Polyethylene Insulation between Braids) DCR 75 C AWG (2) TC Braids % U-500 U (7x28) 96% Shield Coverage TC Inner: 9.5Ω/M 31.0Ω/k Shielding OD Inch DCR Inch 4.7Ω/M 15.5Ω/k Outer: 4.3Ω/M 14.1Ω/k RG-8/U 11 AWG Stranded (7x19).108 Bare Copper Two Bare Copper Braids (96% Shield Coverage) Foa Polyethylene Insulation Black Polyethylene Jacket (Polyethylene Insulation between Braids) 80 C AWG (2) BC % (7x19) 96% Shield.108 Coverage BC Inner: 1.2Ω/M 3.9Ω/k BC = Bare Copper DCR = DC Resistance TC = Tinned Copper Contact the Belden Custoer Service Departent for a Coprehensive Connector Cross Reference BELDEN Ω/M 3.9Ω/k Outer: 2.1Ω/M 4.9Ω/k Belden Electronics Division Technical Support: BELDEN-1 or BELDEN-3

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less) SECTION 260523 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less) PART 1 - GENERAL 1.1 SUMMARY A. Related Documents: 1. Drawings and general provisions of the Subcontract apply

More information

AUDIO & VIDEO CABLES

AUDIO & VIDEO CABLES AUDIO & VIDEO CABLES Speaker Wire AUDIO & VIDEO CABLES 2 Conductor 4 Conductor Commercial Grades Heavy Duty and Professional Grades Home Theater Oxygen Free Outdoor Audio Direct Burial Grades 10 AWG including

More information

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning

More information

Technical Bulletin #27 Wiring for Architectural Applications

Technical Bulletin #27 Wiring for Architectural Applications 400, du Parc, Saint-Eustache, Québec Canada, J7R 0A1 Tel: +1.450.491.5671 +1.800.665.1166 Fax: +1.450.491.3788 www.heicolighting.com Technical Bulletin #27 Wiring for Architectural Applications WIRE SIZE

More information

SECTION INSULATED WIRE AND CABLE

SECTION INSULATED WIRE AND CABLE SECTION 16120 INSULATED WIRE AND CABLE PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Insulated Wire and Cable, which includes the following items with accessories, and appurtenances:

More information

600 VOLT 600V, 3 CONDUCTOR (WITH GROUND), FR-EPR OR FR-XLPE INSULATION, PVC JACKET SPECIFICATIONS (FLAME RETARDANT POWER CABLE) (UL TYPE TC-ER) TYPE C3 SPEC 70.0100 PROJECT 196116 REFERENCE: LATEST EDITIONS

More information

Cable solutions for Automation & Drives

Cable solutions for Automation & Drives www.leoni-industrial-solutions.com Cable solutions for Automation & Drives The Quality Connection Issue 11/2016 All FieldLink products are permanently enhanced for our customers. Therefore this brochure

More information

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder Qualification Reference: 15404201.AA/1-20-2015 Cage Code: 67050 MIL-C-27500 Cables NEMA WC27500 Part Number Builder MIL-C-27500 Cables NEMA WC 27500 Part Number Builder MIL-C-27500 (M27500 Cable) MIL Spec

More information

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

3M Round, Shielded/Jacketed, Flat Cable.050 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 659 Series Round construction permits easier routing 28 AWG wire on.050 inch pitch permits mass termination to broad

More information

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. 37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),

More information

Una e mpre sa Vi akab l e GLOSSARY.

Una e mpre sa Vi akab l e GLOSSARY. GLOSSARY www.centelsa.com.co CONDUCTORS Cu Copper conductors. CuSn Tinned copper conductor. ACDSR Rectangular soft bare copper wire. ACDSRP Paper insulated rectangular soft bare copper wire. ACDD Bare

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

Thermocouple Wire and Cable Insulation THERMOCOUPLE AND EXTENSION GRADE WIRE Type J

Thermocouple Wire and Cable Insulation THERMOCOUPLE AND EXTENSION GRADE WIRE Type J Thermocouple Wire and Cable Insulation THERMOCOUPLE AND EXTENSION GRADE WIRE Type J This Section Contains Insulation Reference Tables Thermocouple Wire Extension Grade Wire Bare Wire Multipair Cable General

More information

Construction guideline

Construction guideline 1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:

More information

*** Supercedes: BECO E and COM , , & ***

*** Supercedes: BECO E and COM , , & *** 7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single

More information

Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection 1Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support Datasheet Protect your networks

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

MIL-W wire. Construction characteristics MIL-W wires. MIL-W part numbering and example

MIL-W wire. Construction characteristics MIL-W wires. MIL-W part numbering and example MIL-W-16878 wire MIL-W-16878 (NEMA HP3, HP4) wires are general-purpose, medium and high-temperature hookup wires, with PTFE or FEP insulation. Each insulation type is available in thin, medium, or heavy

More information

PRODUCT SELECTION LOCATOR

PRODUCT SELECTION LOCATOR PRODUCT SELECTION LOCATOR SECTION SPECIFICATION 1 300V Instrumentation Cables 1000 2 600V Instrumentation Cables 2000 3 600V Flexible Control and Power Cables 3000 4 600V Multi Conductor Control and Power

More information

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool FP30112WHITE100 Heat Shrink TW Tubing Minnesota Mining (3M) Catalog Number FP30112WHITE100 Manufacturer Minnesota Mining (3M) Description Tubing, Heat; ; 600 V; Cable Size 1/2 Inch; Thin Wall; Shrink Temperature

More information

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641

More information

America s Wire Company

America s Wire Company America s Wire Company Dear Customer, We re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of products

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat

More information

WHITE PAPER Flex Life vs Flexibility

WHITE PAPER Flex Life vs Flexibility WHITE PAPER Flex Life vs Flexibility The design criteria for both flex life and flexibility is the same but the properties and application of the elements can be vastly different. The design elements are

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This

More information

Single core conductor BETAtherm 145

Single core conductor BETAtherm 145 Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with

More information

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal) ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or

More information

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring. SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,

More information

Standard of Practice - Campus Electrical Distribution System

Standard of Practice - Campus Electrical Distribution System A26.3 Standard of Practice - Campus Electrical Distribution System NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all

More information

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated

More information

Introduction. Cable Assembly Solutions

Introduction. Cable Assembly Solutions Introduction Cable Assembly Solutions Epec Engineered Technologies is a highly regarded supplier of cable assemblies used in a wide variety of markets including Medical, Industrial, Automotive, and Data

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

DETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE SPECIAL PURPOSE, ELECTRICAL SHIELDED AND UNSHIELDED, GENERAL SPECIFICATION FOR

DETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE SPECIAL PURPOSE, ELECTRICAL SHIELDED AND UNSHIELDED, GENERAL SPECIFICATION FOR INCH-POUND 10 December 1997 SUPERSEDING MIL-C-27500G 23 FEB. 1990 DETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE SPECIAL PURPOSE, ELECTRICAL SHIELDED AND UNSHIELDED, GENERAL SPECIFICATION FOR

More information

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification

More information

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING PRICE LIST NO: FCL/IW.11.17/05 HSN CODE:85 FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL CABLES WITH FLAME RETARDANT PROPERTIES &

More information

A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING

A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING EMI Shielding ARACON fibers braided into a shield or sock offer superior performance against electromagnetic interference. Advantages include: More uniform

More information

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable

More information

Heritage Quality Performance

Heritage Quality Performance FEP FEATURES AND PROPERTIES Heritage Quality Performance Extruded, FEP insulated, high voltage wire and cable offers exceptional dielectric strength without the disadvantages common to equally rated silicone

More information

Phone: Fax:

Phone: Fax: SEPTEMBER 2007 www.nsiindustries.com Phone: 800.321.5847 Fax: 800.841.5566 Mechanical Connectors Dual Rated Single & Double Lugs........................ 1 Panelboard Lugs............................ 1

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

3M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 3476 Series

3M Ground Plane Cable.050 28 AWG Stranded, One Drain, PVC 3476 Series M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 476 Series 28 AWG wire on.050 inch centers permits mass termination to a broad line of IDC connectors Ground plane construction for increased signal

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing CPO 2:1 Shrink Ratio Thin-Wall Tubing, Non-Lined Flame-retardant, cross-linked polyolefin Continuous operating temperature: -55 C to 135 C Shrink temperature of 120 C Meets UL and CSA standards; MIL-DTL-23053/5

More information

PILC Replacement: Getting the Lead Out

PILC Replacement: Getting the Lead Out PILC Replacement: Getting the Lead Out Spring Cincinnati, OH April 30, 2003 Page 1 PILC IS GREAT! Low Profile High Fault Current Capability on Shield High Degree of Water Blocking So why shouldn t you

More information

Shrink-Kon Thin Wall Heat Shrinkable Tubing

Shrink-Kon Thin Wall Heat Shrinkable Tubing Shrink Ratio 2:1 Shrink-Kon Thin Wall Tubing Styles 2:1 Shrink Ratio, Non-Lined Flame retardant. Resistant to common fluids and solvents. Meets UL 224, 125 C; CSA C22.2 No. 198.1, 125 C; MIL-DTL-23053/5

More information

Experience and a History in Construction Products

Experience and a History in Construction Products BDI1004-Brochure 12/14/06 8:41 AM Page 2 Experience and a History in Construction Products Accessory Products. Although Blue Diamond Industries was established in 2004, the management team has experience

More information

LMR-400. LMR -400 Flexible Low Loss Communications Coax TIMES MICROWAVE SYSTEMS

LMR-400. LMR -400 Flexible Low Loss Communications Coax TIMES MICROWAVE SYSTEMS LMR-400 LMR -400 Flexible Low Loss Communications Coax Ideal for Drop-in replacement for RG-8/9913 Air-Dielectric type Cable Jumper Assemblies in Wireless Communications Systems Short Antenna Feeder runs

More information

The Hirschmann TM by Belden Brand Industrial Ethernet Media Solutions

The Hirschmann TM by Belden Brand Industrial Ethernet Media Solutions A BELDEN BRAND The Hirschmann TM by Belden Brand Industrial Ethernet Media Solutions Industrial Ethernet Cordsets 2 and 4 Pair PVC, TPE and TPE High Flex with Bonded Pairs Stranded and The Hirschmann Brand

More information

Electrical Conductors

Electrical Conductors Electrical Conductors Course No: E02-005 Credit: 2 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6 CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................

More information

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire Today s Topics Brief Overview of Southwire In-depth Discussion on Aluminum Characteristics Discussion of

More information

Glossary Of Terms M-1

Glossary Of Terms M-1 Glossary Of Terms ANSI - American National Standards Institute. Armor - A sheath, serving, braid or other layer of metal applied over a cable to increase its mechanical protection. ARR - Association of

More information

3M Electromagnetic Compatible Products

3M Electromagnetic Compatible Products 3M Electromagnetic Compatible Products Selection Guide Revision E 3 Innovation Faster, smaller, lighter, easier the skyrocketing development of today s electronics requires new solutions for significant

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

Technical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

Technical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE Excerpt from PYSMIAN S WIE AND CABLE ENGINEEING GUIDE Page 1 of 9 Areas and diameters of solid and concentric stranded conductors Conductor Size (AWG or kcmil) Area (cma) Solid Wire (mils) weight (lbs/1000

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 4 to 36 optical fibers, Gel filling loose tubes

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 19.10 10 (May 2016) ----------------------------------- Preparing Activity: USACE Superseding UFGS-26 05 19.00 10 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

welding Coleman Cable Inc. is a worldwide leader in the

welding Coleman Cable Inc. is a worldwide leader in the PRODUCTS Introduction Welding Cable Applications NEC Article 630 electric welders Electrode holder & clamp connections to arc welder, bus, welding box or transformer Permanent or temporary lighting Battery

More information

Single-Jacketed Tubing

Single-Jacketed Tubing Single-Jacketed Tubing COILED STICK CUT TO LENGTH UTC Single Jacketed tube Protect the tube against corrosion and pitting in a diverse changing environment and climates. The phenomenon of Chloride Stress

More information

ACT. Summary. 1 Introduction. 2 Synoptic. 3 Technical characteristics. 4 Part-numbering system. 5 Arrangements. 6 Receptacles. 7 Plug / Panel seal

ACT. Summary. 1 Introduction. 2 Synoptic. 3 Technical characteristics. 4 Part-numbering system. 5 Arrangements. 6 Receptacles. 7 Plug / Panel seal Summary 1 Introduction 2 Synoptic 3 Technical characteristics 4 Part-numbering system 5 Arrangements 6 Receptacles 7 Plug / Panel seal 8 Mating and unmating dimensions 9 Mounting cutouts 10-11 Contacts

More information

STANDARD COAXIAL CONNECTORS

STANDARD COAXIAL CONNECTORS STANDARD COAXIAL CONNECTORS COAXI-KIT ISO 9001 APPROVED RADIALL COMPANY PROFILE Since 1952, RADIALL has specialized in the field of coaxial connectors and cables assemblies. RADIALL s experience and high

More information

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola BASIC CONCEPTS IN ELECTRICAL DESIGN Prepared by Engr. John Paul Timola ELECTRICAL CONDUCTORS AND INSULATORS Electrical Conductors substances that offer a very low resistance to current flow. Insulators

More information

FLEXIBLE CONDUITS AND CONNECTORS

FLEXIBLE CONDUITS AND CONNECTORS FLEXIBLE CONDUITS AND CONNECTORS Use the best Use ANAMET! Anamet is a global company with plants in Canada, the United States and Europe. Anamet has manufactured product for the Canadian electrical industry

More information

Mechanical Insulation for Refrigeration Systems

Mechanical Insulation for Refrigeration Systems Mechanical Insulation for Refrigeration Systems INDUSTRIAL REFRIGERATION CONSORTIUM RESEARCH & TECHNOLOGY FORUM MAY 2-3, 2012 Peter Gauchel, President/CEO L&C Insulation Inc. Overview Current trends in

More information

The University of Texas at Austin September 30, 2011

The University of Texas at Austin September 30, 2011 SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATIONS PART 1 - GENERAL 1.1 SUMMARY A. This section governs the products and execution requirements relating to furnishing and installing grounding and

More information

15 Pin DSUB - MALE 15 Pin DSUB - FEMALE 9 Pin DSUB - MALE 9 Pin DSUB - FEMALE

15 Pin DSUB - MALE 15 Pin DSUB - FEMALE 9 Pin DSUB - MALE 9 Pin DSUB - FEMALE Last Revised: 6 Oct 07 Description: This data sheet show our range of high quality appliance cables, such as signal cables (VGA / DVI / DisplayPort (DP)), Touchscreen and power cables. These are either

More information

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified Your Partner for Custom Interconnectivity Solutions ISO 9001 AS9100C ISO 13485 ISO 17025 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven Decades of Expertise

More information

PANDUIT 4-PAIR COPPER DATA CABLE RISER RATED

PANDUIT 4-PAIR COPPER DATA CABLE RISER RATED ENVIRONMENTAL PRODUCT DECLARATION PANDUIT 4-PAIR COPPER DATA CABLE RISER RATED At Panduit, we re serious about sustainability. Everyone s talking about sustainability these days. Companies are making huge

More information

International Thermocouple and Extension Grade Wire Color Codes

International Thermocouple and Extension Grade Wire Color Codes International Thermocouple and Extension Grade Wire Color Codes ANSI Code Alloy Combination + Lead - Lead Color Coding Thermocouple Extension Grade Grade Maximum Useful Range ++ Maximum Thermocouple Grade

More information

Stainless Steel Series MIL-DTL Series III

Stainless Steel Series MIL-DTL Series III 8D - D38999 Stainless Steel Series Stainless Steel Series MIL-DTL-38999 Series III 39 8D Series - MIL-DTL-38999 Series III Description High contact density Screw coupling Contact protection: 100% Scoop

More information

SECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION)

SECTION BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION) SECTION 271400 BACKBONE CABLING SPECIAL NOTE: (REMOVE FROM FINAL DOCUMENTATION) These specifications guidelines detail the intents of KCTCS for Telecommunications Infrastructure Design and Installation.

More information

IDEAL / ARTOS MACHINE SERIES

IDEAL / ARTOS MACHINE SERIES IDEAL / ARTOS MACHINE SERIES THIS SECTION CONTAINS BLADES FOR THE FOLLOWING MACHINE SERIES: 45-048 45-725 45-064 45-774 45-065 45-940 45-700 / 45-705 Your Global Source for Wire Processing Perishable Tooling

More information

15 kv EPR Insulated, Jacketed, URD Cable

15 kv EPR Insulated, Jacketed, URD Cable 15 kv EPR Insulated, Jacketed, URD Cable 1000 kcm Copper Conductor with Tape Shield Page 1 of 11 Table Of Contents 1 GENERAL... 3 2 STANDARDS... 3 3 APPROVED CABLE MANUFACTURERS... 3 4 REEL SPECIFICATIONS...

More information

SPECIFICATIONS: If your preferred product configuration is not shown, please contact our sales representative for custom design.

SPECIFICATIONS: If your preferred product configuration is not shown, please contact our sales representative for custom design. NEW! Series TK SPECIFICATIONS: CONTACT RATING: 200mA / 1.5A @ 5~30VDC. ELECTRICAL LIFE: 1 million cycles at full load. CONTACT RESISTANCE: 20m-ohms max. INSULATION RESISTANCE: 600VDC 10M-ohms min. ESD

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available

More information

THERMOFIT ADHESIVE S Flex Fluid Resistant, High Temperature, One Part-Flexible Epoxy

THERMOFIT ADHESIVE S Flex Fluid Resistant, High Temperature, One Part-Flexible Epoxy TE Connectivity 30 Constitution Drive Menlo Park, CA 9402 USA SPECIFICATION THIS ISSUE: DATE: REPLACES: RT-1014 ISSUE 4 April 19, 2016 Issue 3 1. SCOPE THERMOFIT ADHESIVE S-12-04 Flex Fluid Resistant,

More information

Thermocouples and Accessories Product Catalog

Thermocouples and Accessories Product Catalog Thermocouples and Accessories Product Catalog 7282 N. Haggerty Rd. Canton, MI 48187 P. 734-451-8740 / F. 734-451-8741 www.inspec-inc.com 1 P a g e EXPERT CONTROL AND INSTRUMENTATION REPAIR Plastics Industry

More information

CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG. CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF

CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG. CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF 1 Solutions That Work Eastern Wire + Conduit products provide high quality

More information

etwork etwork-/ethernet-/foc-cable

etwork etwork-/ethernet-/foc-cable etwork etwork-/ethernet-/foc-cable Chainflex eadycable Network-/Ethernet-/FOC-cable Cable type Jacket Page CFLG.6G Gradient fiber glass cable TPE 226 CFLG.12G Gradient fiber glass cable TPE 228 CAT5 Ethernet

More information

WIRING PROTECTOR. Edge holder EH-1 series 72 EHS/EHP series 73 LT series 74. Free bush SG series 75. EL free bush EL series 75. Grommet ESG series 76

WIRING PROTECTOR. Edge holder EH-1 series 72 EHS/EHP series 73 LT series 74. Free bush SG series 75. EL free bush EL series 75. Grommet ESG series 76 W I R I N G A C C E S S O R Y 70 Edge holder EH-1 series 72 EHS/EHP series 73 LT series 74 Free bush SG series 75 EL free bush EL series 75 Grommet ESG series 76 Edging EE/EO series 76 Spiral tubing SS

More information

SECTION P -- CABLE VAULT AND CABLE ENTRANCE FACILITY

SECTION P -- CABLE VAULT AND CABLE ENTRANCE FACILITY INSTLLTION REQUIREMENTS Section P, TT-TP-76300 T&T January 2012 Revised July, 2012 SECTION P -- CLE VULT ND CLE ENTRNCE FCILITY CONTENTS PGE 1. GENERL... P-1 1.1. Introduction... P-1 1.2. Non-Insulating

More information

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional

More information

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution Serv Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution General Cable offers a complete line of insulated cable designs and sizes to meet utility requirements for exceptional

More information

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered. 2012 Edition Redbook 8.0 REVENUE METERING 8.1 INTRODUCTION The purpose of this section is to outline requirements of the Customer, as set forth herein by LIPA, as they pertain to Electric Revenue Metering

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 6/15/16 Updated division section from 16124 to 2605 - mgl44 13, removed references to other section 10/17/14

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100) ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 15 2006 (Formerly IPS SP 100) Specification for Trunk, Feeder and Distribution Coaxial Cable NOTICE The Society

More information

750 N A 100 M P

750 N A 100 M P onduit Assemblies Legacy Adapter to Adapter Series 72 & 74 Tubing & Series 75 onduit or use with adapters and transitions shown in Table III OR AAPTR-TO-AAPTR APPLIATIONS Product Series 750 = Series 75

More information

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU INCH-POUND MIL-DTL-24643/17F 1 October 2009 SUPERSEDING MIL-DTL-24643/17E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU This specification is approved

More information

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00. To: National Cables Industry P.O Box 27472 Al Dhaid Road, Al Sajja Industrial Area Sharjah U.A.E TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE Kinectrics International Inc. Report No.: K-422341-RC-0001-R00

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

Table of Contents. Applications...3 Medical...4 Industrial...5

Table of Contents. Applications...3 Medical...4 Industrial...5 Table of Contents Applications...3 Medical...4 Industrial...5 Extruded Sizes...7 PTFE Sub-Lite-Wall Extruded&HeatShrinkableTubing...8 ExtrudedTubing(AWG)...10 HeavyConstructionTubing...14 HeavyWallTubing...15

More information

80M 4-Square. An antenna project to obtain a bigger signal on the 80 Meter (3.5 to 3.8 MHz) amateur radio band. Bruce Whitney W8RA

80M 4-Square. An antenna project to obtain a bigger signal on the 80 Meter (3.5 to 3.8 MHz) amateur radio band. Bruce Whitney W8RA An antenna project to obtain a bigger signal on the 80 Meter (3.5 to 3.8 MHz) amateur radio band Bruce Whitney W8RA The Goal: Convert a vacant back field into 4.2 db of power (directional) gain Switchable

More information

The Company by Peter Bröckskes sen. an independent, middle sized company

The Company by Peter Bröckskes sen. an independent, middle sized company The Company DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff

More information

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 16450 GROUNDING ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 26 An optional keynote to the

More information

Table of Contents. Applications...3. Extruded Sizes...7. Value Added Services Heat Shrinkable Extrusions Technical Information...

Table of Contents. Applications...3. Extruded Sizes...7. Value Added Services Heat Shrinkable Extrusions Technical Information... Table of Contents Applications...3 Medical...4 Industrial...5 Extruded Sizes...7 PTFE Sub-Lite-Wall Extruded&HeatShrinkableTubing...8 ExtrudedTubing(AWG)...10 HeavyConstructionTubing...14 HeavyWallTubing...15

More information

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information