TEMPSENS I N S T R U M E N T S. w w w. t e m p s e n s. c o m. -ve Temperature Bath. Liquid Bath. Dry Block Furnaces. Black Body Sources
|
|
- Marilyn Ward
- 6 years ago
- Views:
Transcription
1 -ve Temperature Bath Liquid Bath Dry Block Furnaces Black Body Sources Temperature Reference Junction Box Thermocouple and PRT Thermometers Reference Thermocouples and PRTs calibrators Cold Junction Probes Lab Automation NABL Accredited Temperature Calibration Onsite Temperature Calibration TEMPSENS w w w. t e m p s e n s. c o m
2 TOTAL SOLUTION FOR TEMPERATURE CALIBRATION What is Calibration The comparison of a measuring instrument against an accurate standard to determine any deviation. The device with known assigned correctness is called the Standard. The second device is the Unit Under Test (UUT). Accurate Temperature Calibration Temperature Calibration has many facets. It can be carried out thermally in the case of probes or electrically in the case of Instrument and it can be performed directly with certified equipment, or indirectly with traceable standards. Thermal (Temperature) calibration is achieved by elevating (or depressing) the temperature sensor to a known, controlled temperature and measuring the corresponding change in its associated electrical parameter (voltage or resistance). The accurately measured parameters compared with that of a certified reference probe; the absolute difference represents the calibration error. If the sensor is connected to a measuring instrument, the sensor and the instrument combination can be effectively calibrated by this technique. A typical general purpose system comprises of a thermal reference (stable temperature source), a certified reference probe with its certificate, a precision electronic digital thermometer, bridge or digital voltmeter. Temperature Source Dry Block Calibrator Provides the most convenient, portable facilities for checking & calibrating industrial probes and they are usually reasonable rapid heating and cooling device. The unit consists of a special designed heating block which has located internal holes for the probes. Although the block temperature is accurately controlled, any indication provided should be used for guidance only. As with any comparison technique a certified sensor and indicator should be used to measure the block temperature and used as a reference for the test probe. Two types of unit are available; portable units which can be taken on to plant for the on-site calibration and laboratory units to which industrial sensors are brought as required. Stirred Liquid Bath Provide superior thermal environment for probe immersion as no air gap exist between the probe and the medium Thermal coupling is therefore much better than the alternatives described, and the stirring results in very even heat distribution throughout the medium. Methanol is used for temperature below C, water from to 8 C and silicon oil for upto 25 C. Black Body Source Black bodies are reference sources used for testing infrared systems. They are required in industry for calibration of pyrometers, infrared line scanners or cameras. In laboratory, they are part of benches for characterization of complex optronic systems. Tempsens offers a wide range of black bodies to cover all Customer s needs. Cold Junction Compensation By connecting any thermocouple to measurement device three dissimilar metal junction are created in the circuit: the thermocouple junction itself, or hot junction, and the junction between each lead and the measurement device, or cold junctions. These cold junction provide their own thermoelectric voltages that are proportional to the temperature at the device terminals. A technology known as cold junction compensation is therefore used to remove this unwanted effect. Referernce Unit In case of accurate thermocouple measurement, it s a common practice to reference the cold junction temperature at ice point ( C) so that copper leads may be connected to an EMF readout device. This procedure avoids the compensation of cold junction temperature at the terminal of read out which may not be constant and the measurement may not be very accurate.
3 TOTAL SOLUTION FOR TEMPERATURE CALIBRATION TEMPERATURE SOURCES Contact Type Non Contact Type Stability o Temperature Range ( C) Calsys-8/ Calsys-4/ Calsys-35/ Calsys-35/2 Calsys-15/ Calsys12SP.1 12 Calsys Calsys3SP Calsys CalsysFB Calsys Calsys12L Calsys12 3Z Calsys15L Calsys17L Calsys11BB Calsys5BB Calsys12BB Calsys15BB Calsys17BB Fast Cal Fast Cal Bath Dry Block Black Body MASTER SENSOR STABLE REFERENCE UNIT SENSOR RTD Thermocouple SSPRT TYPE PT 25.5 PT 1 PT 2 K/N Type R/S Type _ O RANGE( C) -8 to 4-8 to 25-8 to 25-8 to 25 to 12 to 15 upto 66 ACCURACY Class A 1/3 DIN 1/5 DIN 1/1 DIN ± 1.1 C OR ±.4% ±.6 C OR ±.1% long term drift ±5mk/Yr. TYPE CALref CALref 6 Channel 2 Ref. temp. Type of Junction Wall Mounted Model Portable Model C J,K,T,E,N,R,S,B 24 6 C J,K,T,E,N,R,S,B Reference temperature could be change according to customer requirement To be specified at time of ordering
4 -8/5-8 to 5 C HIGH STABILITY BATH -8/5 is a Highly Stable Stirred Liquid Bath for Calibration RTD / Thermocouple and also for compensation of cold junction. -8/5 offers the temperature range of -8 to 5 C. It has large tank which is filled with liquid Methanol. The liquid is heated or cooled to the desired temperature. It has better stability & uniformity than dry block bath and as it uses of stirred liquid. This -8/5 is built using CFC free refrigerants. Large Immersion Depths High Accuracy High Stability and Uniformity Wide Temperature Range PC Interface Simple to use and Cost effective Ÿ Reference Standard PRT...Part No. TPRT-A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Methanol...1 Ltr. No.(35-M) Temp. Range : -8 to 5 C Stability : ±.4 C at -8 C (Methanol) ±.7 C at C (Methanol) ±.5 C at 5 C (Water) Uniformity : ±.5 C at -8 C ±.9 C at C ±.7 C at 5 C Temperature Resolution :.1 C Time to Reach Min. Temp. : 2 Hrs Medium : Methanol Controlling Sensor : PT-1 Volume : 9 Ltr. Access Opening : 1 x 13 mm Depth : 2 mm Method of control : Digital self tuned PID Controller Operating Temperature : 2 to 25 C Power Requirement : 23 VAC, 2. KW Dimensions : 75 x 85 x 65 mm Weight : 8 Kgs. (Large depth available on custom built model)
5 -4/5-4 to 5 C HIGH STABILITY BATH -4/5 is a Highly Stable Stirred Liquid Bath for Calibration RTD / Thermocouple and also for compensation of cold junction. -4/5 offers the temperature range of -4 to 5 C. It has large tank which is filled with liquid Methanol. The liquid is heated or cooled to the desired temperature. It has better stability & uniformity than dry block bath and as it uses of stirred liquid. This -4/5 is built using CFC free refrigerants. -4/5 Large Immersion Depths High Accuracy High Stability and Uniformity Wide Temperature Range PC Interface Simple to use and Cost effective Ÿ Reference Standard PRT...Part No. TPRT-A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Methanol...5 Ltr. No.(35-M) Temp. Range : -4 to 5 C Stability : ±.4 C at -4 C (Methanol) ±.7 C at C (Methanol) ±.5 C at 5 C (Water) Uniformity : ±.5 C at -4 C ±.9 C at C ±.7 C at 5 C Temperature Resolution :.1 C Time to Reach Min. Temp. : 1.5 Hrs Medium : Methanol Controlling Sensor : PT-1 Volume : 3 Ltr. Access Opening : 9 x 9 mm Depth : 15 mm Method of control : Digital self tuned PID Controller Operating Temperature : 2 to 25 C Power Requirement : 23 VAC, 2. KW Dimensions : 5 x 35 x 45 mm(approx.) Weight : 4 Kgs. (Large depth available on custom built model)
6 -35/5-35 to 5 C HIGH STABILITY THERMOSTAT TESTING BATH -35/5 is a Highly Stable Stirred Liquid Bath for testing of multiple thermostats simultaneously. Thermostats offers the temperature range of -35 to 5 C. It has large tank which is filled with liquid Methanol. The liquid is heated or cooled to the desired temperature. It has continues stirrer liquid provides uniform temperature distribution. This -35/5 is built using CFC free refrigerants. It specially designed to test 5 numbers of thermostat at a time. LED Light Indication for each thermostat Large Immersion Depths High Accuracy High Stability and Uniformity Wide Temperature Range PC Interface Simple to use and Cost effective Ÿ Reference Standard PRT...Part No. TPRT-A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Methanol...1 Ltr. No.(35-M) Temp. Range : -35 to 5 C Stability : ±.4 C at -35 C (Methanol) ±.7 C at C (Methanol) ±.5 C at 5 C (Water) Uniformity : ±.5 C at -35 C ±.9 C at C ±.7 C at 5 C Temperature Resolution :.1 C Time to Reach Min. Temp. : 2 Hrs Medium : Methanol Controlling Sensor : PT-1 Access Opening : 22 x 18 mm Depth : 25 mm Method of control : Digital self tuned PID Controller Operating Temperature : 2 to 25 C Power Requirement : 23 VAC, 2. KW Dimensions : 75 x 85 x 65 mm Weight : 8 Kgs. (Large depth available on custom built model)
7 -35/2-35 to 2 C HIGH STABILITY BATH -35/2 is a Highly Stable Stirred Liquid Bath for calibrating RTD / Thermocouple and also for compensation of cold junction. CALSys -35/2 offers the temperature range of - 35 to 2 C. It has large well which is filled with liquid (Water+Methanol /Silicon Oil). The liquid is heated or cooled to the desired temperature. Methanol+Water is used for Negative Temperature and Silicon Oil for Heating. It has better stability & uniformity than dry block bath and as it uses of stirred liquid. This -35/2 is built using CFC free refrigerants. High Accuracy High Stability and Uniformity Wide Temperature Range PC interfacing Simple to use and cost effective LCD screen controller Level Alarm Ÿ Reference Standard PRT Part No.TPRT-A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME. Ÿ Operational Manual OPTIONAL ACCESSORIES Methanol...1 Ltr. No.(35-M) Silicon Oil...1L Part No.C2S-LB SO Temp Range : -35 to 2 C Stability : ±.1 C at -35 C (Methanol) ±.5 C at- C (Methanol) ±.4 C at 2 C (Silicon Oil) Uniformity : ±.3 C at -35 C ±.7 C at C ±.7 C at 2 C Temperature Resolution :.1 C Time to Reach Max Temp : 1.5 Hrs Medium Cooling : Methanol + Water Medium Heating : Silicon Oil Controlling Sensor : PT-1 Volume : 7 Ltr. Access Opening : 157(L) x 142(W) Depth : 127 mm Method of Control : Digital self tuned PID Controller Operating Temperature : 2 to 25 C Wetted Part : SS-34 Power Requirement : 23 VAC, 2. KW Dimensions : 54(L) x 22(W) x 62(H)mm Weight : Approx 41 Kg
8 -15/11-15 to 11 C PELTIER BASED TEMPERATURE CALIBRATOR -15 / 11 offers medium temperature range from -15 to 11 C. It is a highly stable standard temperature source for calibrating RTD / thermocouples. It has peltier elements to generate stable temperature in the well. The comparison volume is a metallic block of aluminum, which has diameter of 24mm and 12mm length. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Wide Operating Range (-15 to11 C) High Stability PC interfacing Simple to use and cost effective Portability Ÿ Reference Standard PRT...Part No.TPRT -A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Ÿ Carry Case OPTIONAL ACCESSORIES Extra Equalizing Block Temperature Range : -15 to 11 C Temperature Resolution :.1 C Stability : Uniformity : ±.3 C at-15 C ±.5 C at C ±.7 C at 11 C ±.5 C at -15 C ±.7 C at C ±.9 C at 11 C Controlling Sensor : Precision PRT Method of Control : Digital self tuned PID Controller Removable Insert Construction : Dia 24 x 12 mm long, 3 x 6 mm hole with 115mm insertion depth Time to Reach Max/Min Temp : 25 Mins Operating Temperature : 2 to 25 C Power Requirement : 23 VAC, 5 W Dimensions : 38(H) x 17(W) x 188(D) mm Weight : Approx 14 Kg
9 12 SP to 12 C DRY CUM LIQUID BATH PELTIER BASED TEMPERATURE CALIBRATOR 12SP offers medium temperature range from to 12 C. It is a highly stable standard temperature source for calibrating RTD / thermocouples. It has peltier elements to generate stable temperature in the well. Use as a dry block & liquid bath using magnetic stirrer in one model. The comparison volume is a metallic block of aluminum, which has diameter of 24mm and 1mm length. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Wide Operating Range ( to12 C) High Stability PC interfacing Simple to use and cost effective Portability Ÿ Reference Standard PRT...Part No.TPRT -A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Ÿ Carry Case OPTIONAL ACCESSORIES Extra Equalizing Block 12SP Temperature Range : to 12 C Temperature Resolution :.1 C Stability : ±.3 C at C ±.5 C at C ±.7 C at 12 C Uniformity : ±.5 C at C ±.7 C at C ±.9 C at 12 C Controlling Sensor : Precision PRT Medium : Silicon Oil (for liquid bath) Method of Control : Digital self tuned PID Controller Removable Insert Construction : Dia 24 x 1 mm long, 3 x 6 mm hole Time to Reach Max/Min Temp : 25 Mins Operating Temperature : 2 to 25 C Power Requirement : 23 VAC, 5 W Dimensions : 38(H) x 17(W) x 188(D) mm Weight : Approx 14 Kg
10 25 5 to 25 C HIGH ACCURACY LIQUID CALIBRATION BATH 25 calibration bath is a highly stable standard stirred liquid bath for calibrating RTDs / Thermocouples and other temperature sensors in the laboratory. The temperature of the bath is set and controlled by a self tuned PID controller with automatic super fine adjustment. The unique features is portability with very high stability and uniformity. The medium used in the bath is silicon oil. Large Immersion Depths Wide Operating Range (5 to 25 C) High Stability and Uniformity PC interfacing Simple to use and cost effective Portability Ÿ Silicon Oil... Part No.C3S-LB-SO Ÿ Reference Standard PRT Part No.TPRT-A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Ÿ Carry Case OPTIONAL ACCESSORIES Silicon Oil...Part No C2S-LB-SO Temperature Range : 5 to 25 C Temperature Resolution :.1 C Stability : ±.15 C at 5 C ±.25 C at 15 C ±.5 C at 25 C Uniformity : ±.2 C at 5 C ±.4 C at 15 C ±.8 C at 25 C Controlling Sensor : Precision PRT (PT-1) Method of Control : Digital self tuned PID Controller Medium of Heating : Silicon Oil Time to Reach Max Temp : 3 Mins Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 1. KW Dimensions : 36(H) x 185(W) x 285(D) mm Access Opening : 9 mm Dia Depth : 14 mm Removable Insert Construction : 6 holes of 15 mm Dia Weight : Approx 12 Kg Volume : 9 ml Wetted Parts : Aluminium (Large depth available on custom built model)
11 3 SP 5 to 25 C HIGH ACCURACY LIQUID CALIBRATION BATH 3SP calibration bath is a highly stable standard stirred liquid bath for calibrating RTDs / Thermocouples and other temperature sensors in the laboratory. The temperature of the bath is set and controlled by a self tuned PID controller with automatic super fine adjustment. The unique features is portability with very high stability and uniformity. The medium used in the bath is silicon oil. Large Immersion Depths Wide Operating Range (5 to 25 C) High Stability and Uniformity PC interfacing Simple to use and cost effective Temperature Range : 5 to 25 C Temperature Resolution :.1 C Stability : ±.1 C Uniformity : ±.2 C Controlling Sensor : Precision PRT (PT-1) Method of Control : Digital self tuned PID Controller Ÿ Silicon Oil... Part No.C3S-LB-SO Ÿ Reference Standard PRT Part No.TPRT-A-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Ÿ Carry Case Medium of Heating : Silicon Oil Time to Reach Max Temp : 45 Mins Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 2. KW Dimensions : 6(H) x 35(W) x 55(D) mm Access Opening : 12 mm Dia Depth : 3 mm Weight : Approx 2 Kg OPTIONAL ACCESSORIES Silicon Oil...Part No C2S-LB-SO
12 65 5 to 65 C PORTABLE CALIBRATOR 65 offers medium temperature range from 5 to 65 C. It is a highly stable standard furnace for calibrating thermocouples / RTD. It has been designed for medium range temperature calibration and find application in the glass, electrical power, automotive & material processing industries. The comparison volume is a metallic block of special material, which has diameter of 32mm and 15mm long The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Large Immersion Depths Wide Operating Range (5 to 65 C) High Stability PC interfacing Simple to use and cost effective Ÿ Reference Standard Thermocouple ( K Type T/C) Part No. TTCK-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Ÿ Carry Case Temperature Range : 5 to 65 C Temperature Resolution :.1 C Stability : ±.25 C at 5 C ±.35 C at 35 C ±.7 C at 65 C Uniformity : ±.4 C at 5 C ±.7 C at 35 C ±.9 C at 65 C Controlling Sensor : T/C N TYPE Method of Control : Digital self tuned PID Controller Insert Construction : Dia 32 x 15 mm long with 4 holes of 6.5 x 12 mm insertion depth Time to Reach Max Temp : 25 Mins Time to Reach Max Temp to 1 C : 7 Mins Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 1 KW Dimensions : 325(H) x 185(W) x 265(D) mm Weight : Approx 1 Kg OPTIONAL ACCESSORIES Customized Equalizing Block...Part No. EQ1 Carrying Case Interchangeable Inserts (as per requirement)
13 FB 5 to 65 C FLUIDIZED BATH FB offers medium temperature range from 5 to 65 C. It is a high stable fluidized bath for calibration thermocouple & RTD. It has been designed for medium temperature calibration with high satiability and maximum uniform temperature zone. Alumina powder is used as medium. Metallic probes are used with probe holder for calibration which is 28 mm long with 8mm diameter. Temperature of furnace is set and controlled by self tuned PID controller with automatic super fine adjustment. High Uniform zone Wide Operating Range (5 C - 65 C) High Stability No. of Sensor Calibrated Simultaneously Reference Standard Thermocouple ( N type T/C)...Part No. TTCN-3 Operational Manual Temperature Range : 5 to 65 C Ded Bed :.5 C Stability : ±1. C Display Resolution :.1 C Type of Control : Digital self Tuned PID Controller Sensor Type: N type thermocouple Heat up time 2 C to65 C : 15 Minutes Air pressure kpa (psi) : 42 (6) Nominal Heater Power at 24V (W) : 3 Weight of medium : 16 kg (35 lbs) Working volume (diameter x Depth) : 15 x 385mm Overall Size L x W x H : 87 x 515 x 6mm Shipping weight : 84 kg (185 lbs) Serial communication : RS 232 Power req. : 23VAC, 3 Kw Operating temp. : 2 to 45 C
14 12 25 to 12 C PORTABLE THERMOCOUPLE CALIBRATOR 12 offers high temperature range from 25 to 12 C. It is a highly stable standard furnace for calibrating Thermocouples / RTD. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive & material processing industries. The comparison volume is a metallic block of special material, which is 37 mm in diameter with 215 mm long. The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Version with 3 zone furnace is also available. Large Immersion Depths Wide Operating Range (25 to 12 C) High Stability PC interfacing Simple to use and cost effective Ÿ Reference Standard Thermocouple ( N Type T/C) Part No. TTCN-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Ÿ Carry Case Temperature Range : 25 to 12 C Temperature Resolution : 1. C Stability : ±.1 C at 25 C ±.2 C at 7 C ±.4 C at 12 C Uniformity : ±.2 C at 25 C ±.24 C at 7 C ±.26 C at 12 C Controlling Sensor : PT/RH-PT T/C Method of Control : Digital self tuned PID Controller Insert Construction : Dia 37 x 215 mm long (2X6mm & 2X8 mm holes) of 16mm insertion depth Time to Reach Max Temp : 1.5 Hrs Cooling Time 12 C to 25 C : 18 Mins Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 1.5 KW Dimensions : 45(H) x 25(W) x 285(D) mm Weight : Approx 14 Kg OPTIONAL ACCESSORIES Customized Equalizing Block...Part No. EQ2 Carrying Case Interchangeable Inserts (as per requirement)
15 12L 3 to 12 C HIGH STABILITY BLOCK FURNACE 12L calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory. The temperature of the furnace is set and controlled by a self tuned PID controller with automatic super fine adjustment. The standard insert is a metallic block of special material, which is 37mm in diameter with 24 mm long and can hold up to four thermocouples. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive, material processing industries & laboratories. Special Version with 3 zone furnaces are available. Large Immersion Depths Wide Operating Range (3 to 12 C) High Stability PC interfacing Simple to use and cost effective Ÿ Reference Standard Thermocouple ( N Type T/C) Part No. TTCN-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Temperature Range : 3 to 12 C Temperature Resolution : 1. C Stability : ±.1 C at 3 C ±.2 C at 7 C ±.35 C at 12 C Uniformity : ±.15 C at 3 C ±.25 C at 7 C ±.4 C at 12 C Controlling Sensor : Precision PT/RH-PT T/C Method of Control : Digital self tuned PID Controller Insert Construction : Dia 37 x 24 mm long (2X6mm & 2X8 mm holes) of 16mm insertion depth Time to Reach Max Temp : 1.5 Hrs Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 2. KW Dimensions : 5(H) x 4(W) x 49(D) mm Weight : Approx 5 Kg OPTIONAL ACCESSORIES Extra Equalizing Block Part No. EQ2 Optional Block
16 12 3Z 3 to 12 C HIGH STABILITY BLOCK FURNACE 12 3Z calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory. The temperature of each zone of the furnace is set and controlled by a self tuned PID controller(master + Slave) with automatic super fine adjustment. The standard insert is a metallic block of special material, which is 37mm in diameter with 24 mm long and can hold up to four thermocouples. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive, material processing industries & laboratories. Large Immersion Depths Wide Operating Range (3 to 12 C) High Stability PC interfacing Simple to use and cost effective Ÿ Reference Standard Thermocouple ( N Type T/C) Part No. TTCN-3 Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual 12 3Z Temperature Range : 3 to 12 C Temperature Resolution : 1. C Stability : ±.1 C at 3 C ±.2 C at 7 C ±.35 C at 12 C Redial Uniformity : ±.35 at 12 C Axial Uniformity : ±1. C up to 8mm at 12 C Controlling Sensor : Precision PT/RH-PT T/C No. of Zone : Three Method of Control : Digital self tuned PID Controller Insert Construction : Dia 37 x 24 mm long (2X6mm & 2X8 mm holes) of 16mm insertion depth Time to Reach Max Temp : 1.5 Hrs Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 2. KW Dimensions : 5(H) x 4(W) x 49(D) mm Weight : Approx 5 Kg Optional Block
17 15L 5 to 15 C HIGH STABILITY BLOCK FURNACE 15L calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory. The temperature of the furnace is set and controlled by a self tuned PID controller with automatic super fine adjustment. The standard insert is a Ceramic Tube, which is 37 mm in diameter with 245 mm long and can hold up to four thermocouples. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive & material processing industries and laboratories. Use of Silicon Carbide Spiral Rod Heaters Large Immersion Depths Wide Operating Range (5 to 15 C) High Stability PC interfacing Simple to use and cost effective Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Reference Standard Thermocouple (PT-RH/PT R Type T/C) Part No. TTCR-3 Extra Equalizing Block Part No. Eq2 Temperature Range : 5 to 15 C Temperature Resolution : 1. C Stability : ±.4 C at 5 C ±.7 C at 1 C ±1. C at 15 C Uniformity : ±.6 C at 5 C ±.8 C at 1 C ±.9 C at 15 C Controlling Sensor : PT-RH/PT T/C Method of Control : Digital self tuned PID Controller Insert Construction : Dia 37 x 245 mm long (2X6mm & 2X8 mm holes) of 14mm insertion depth Heaters : Silicon Carbide Spiral Rod Heater Time to Reach Max Temp : 2 Hrs Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 3. KW Dimensions : 57(H) x 45(W) x 52(D) mm Weight : 55 Kg
18 17L 5 to 17 C HIGH TEMPERATURE BLOCK FURNACE 17L calibration source is a highly stable standard furnace for calibrating thermocouples in the laboratory. The temperature of the furnace is set and controlled by a self tuned advanced PID controller with automatic super fine adjustment. The standard insert is a Ceramic Tube, which is 37 mm in diameter and 24 mm long and can hold up to four thermocouples. It has been designed for high temperature range calibration and find application in the glass, electrical power, automotive & material processing industries and laboratories. Use of Molybdenum Disilicate Heaters (MoSiO2) Large Immersion Depths Wide Operating Range (5 to 17 C) High Stability PC interfacing Simple to use and cost effective Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Reference Standard Thermocouple (PT-RH/PT B Type T/C) Part No. TTCB-3 Extra Equalizing Block Black Body Cavity.Part No. Eq3 Temperature Range : 5 to 17 C Temperature Resolution :.1 C Stability : ±.5 C at 5 C ±1. C at 12 C ±1.5 C at 17 C Uniformity : ±.7 C at 5 C ±1.4 C at 12 C ±1.9 C at 17 C Controlling Sensor : Precision PT/RH-PT T/C Heaters : MoSiO2 Method of Control : Digital self tuned PID Controller Insert Construction : Dia 37 x 24 mm long (2x6mm & 2x8 mm holes) of 225mm insertion depth Time to Reach Max Temp : 3 Hrs Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 3 KW Dimensions : 64(H) x 5(W) x 55(D) mm Weight : 8 Kg
19 11BB 1 to 11 C PORTABLE BLACK BODY 11BB calibration source is a highly stable standard Portable Black Body Furnace for calibrating non contact IR thermometer for the temperature range of 1 to 11 C. The unique feature of this Portable Black Body Furnace is large temperature controlled black body target with a Size of 8x8 mm which offer large view area for IR Thermometer The Emissivity of the target is.95(±.1). The temperature of the furnace is set and controlled by a self tuned PID controller with automatic super fine adjustment. 11 Large Aperture Area Below Ambient Operating Range (1 to 11 C) High Stability PC interfacing Simple to use and cost effective Portability Carry Case Operational Manual OPTIONAL ACCESSORIES Master Pyrometer Temperature Range : 1 to 11 C Temperature Resolution :.1 C Stability : ±.1 C Controlling Sensor : Precision PRT Method of Control : Digital self tuned PID Controller Emissivity :.95 ±.1 Time to Reach Max Temp : 25 Mins Operating Temperature : 2 to 25 C Power Requirement : 23 VAC,.5 KW Dimensions : 33(H) X 355(W) X 225(D) mm Cavity : High Emissive Painted Aluminum Plate Aperture : 8 x 8 mm Weight : Approx 1 Kg
20 5BB 5 to 5 C PORTABLE BLACK BODY 5BB calibration source is a highly stable standard Portable Black Body Furnace for calibrating non contact IR thermometer for the wide temperature range of 5 to 5 C. The unique feature of this Portable Black Body Furnace is large temperature controlled black body target with a diameter of 1 mm which offer large view area for IR Thermometer The Emissivity of the target is.95(±.1). The temperature of the Calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Large Aperture Area Wide Operating Range (5 to 5 C) High Stability PC interfacing Simple to use and cost effective Portability Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual Ÿ Carry Case Temperature Range : 5 to 5 C Temperature Resolution :.1 C Stability : ±.5 C at 5 C ±.8 C at 25 C ±1. C at 5 C Controlling Sensor : T/C N type Method of Control : Digital self tuned PID Controller Emissivity :.95 ±.1 Time to Reach Max Temp : 45 Mins Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 1. KW Dimensions : 32(H) X 355(W) X 255(D) mm Target Size : Dia - 1 mm (Ridged Aluminum Plate) Weight : Approx 1 Kg OPTIONAL ACCESSORIES Master Pyrometer
21 12BB 3 to 12 C HIGH STABILITY BLACK BODY FURNACE 12BB calibration source is a highly stable standard Black Body Furnace for calibrating non contact IR thermometer for the wide temperature range of 3 to 12 C. The unique feature of this Black Body Furnace is large temperature controlled black body target with a diameter of 5 mm and 3mm which offer large view area for IR Thermometer. The Emissivity of the target is.99(±.1).the temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Wide Operating Range (3 to 12 C) High Stability PC interfacing Simple to use and cost effective Sighting tube Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Master Pyrometer Black Body Cavity Part No. EQ3 Temperature Range : 3 to 12 C Temperature Resolution : 1. C Stability : ±.2 C at 5 C ±.3 C at 8 C ±.5 C at 12 C Controlling Sensor : Precision PT/RH-PT T/C Method of Control : Digital self tuned PID Controller Time to Reach Max Temp : 1.5 Hrs Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 2.5KW Dimensions : 58(H) x 5(W) x 675(D) mm Radiation Cavity Type & Dimension : Silicon Carbide, 5 mm Dia x 3mm depth Sighting Tube Dimension : 37±1mm dia & 14mm depth Weight : Approx 65 Kg
22 15BB 5 to 15 C HIGH STABILITY BLACK BODY FURNACE 15BB calibration source is a highly stable standard Black Body Furnace for calibrating non contact IR thermometer for the wide temperature range of 5 to 15 C. The unique feature of this Black Body Furnace is large temperature controlled black body target with a diameter of 5 mm and depth 3mm which offer large view area for IR Thermometer. The Emissivity of the target is.99(±.1). The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Use of Silicon Carbide Spiral Rod Heaters Wide Operating Range (5 to 15 C) High Stability PC interfacing Simple to use and cost effective Sighting tube Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Black Body Cavity.Part No. EQ3 Temperature Range : 5 to 15 C Temperature Resolution : 1. C Stability : ±.4 C at 5 C ±.7 C at 1 C ±1. C at 15 C Controlling Sensor : PT-RH/PT T/C Method of Control : Digital self tuned PID Controller Heaters : Silicon Carbide Spiral Rod Heater Time to Reach Max Temp : 2.5 Hrs Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 3.5 KW Dimensions : 58(H) x 5(W) x 675(D) mm Radiation Cavity Type & Dimension : Silicon Carbide, 5 mm Dia x 3mm depth Sighting Tube Dimension : 37±1mm dia & 14mm depth Weight : 65 Kg
23 17BB 5 to 17 C HIGH TEMPERATURE BLACK BODY FURNACE 17BB calibration source is a highly stable standard Black Body Furnace for calibrating non contact IR thermometer for the wide temperature range of 5 to 17 C. The unique feature of this Black Body Furnace is large temperature controlled black body target with a diameter of 29 mm which offer large view area for IR Thermometer. The Emissivity of the target is.97(±.1). The temperature of the calibrator is set and controlled by a self tuned PID controller with automatic super fine adjustment. Use of Molybdenum Disilicide Heaters (MoSiO2) Wide Operating Range (5 to 17 C) High Stability PC interfacing Simple to use and cost effective Ÿ NABL accredited calibration certificate - 3 point Ÿ Software - Cal Soft including for setting bath temperature and monitoring the PV. Graphical representations of PV/TIME with 2 hours data logging. Ÿ Operational Manual OPTIONAL ACCESSORIES Master Pyrometer Black Body Cavity. Part No. EQ3 Temperature Range : 5 to 17 C Temperature Resolution :.1 C Stability : ±.7 C at 5 C ±1.4 C at 12 C ±2. C at 17 C Controlling Sensor : Precision PT/RH-PT T/C Heaters : MoSiO2 Method of Control : Digital self tuned PID Controller Time to Reach Max Temp : 3 Hrs Operating Temperature : 2 to 45 C Power Requirement : 23 VAC, 3 KW Dimensions : 64(H) x 5(W) x 55(D) mm Black Body Cavity Aperture : 29 mm, End closed tube Weight : 8 Kg
24 Fast Cal Fast Cal 12 C Fast CAL is a time saving way to calibrate pyrometer with range upto 12 C Now the pyrometer can be calibrated within few minutes using highly precise PID controller and a Controlling Pyrometer. Temperature Range : 3 to 12 C Temperature Resolution :.1 C Stability : ±1 C Emissivity :.95 (±.1) Controlling Sensor : Pyrometer Method of control : Digital self tuned advanced PID controller Time to Reach Max Temp. : 3 sec. (max.) Operating Temperature : 2 to 45 C Power required : 23 V AC, 3 KW Dimension : 9(L)x 6(W)x 44(H) mm Weight : 7 Kg Fast Cal 26 C The Fast cal 26 is an ultra high temperature black body calibrator and capability to produce very high temperature, high emissivity emitters and at the same time stabilize at the required temperature with in minutes of switch on. All Safety features to protect equipment and operator are easily accessible. The Target temperature is sensed by a rapid response infrared fiber optic pyrometer which drives a PID Controller to regulate the cavity temperature precisely to the desired set point. Temperature Range : 7 to 26 C Temperature Resolution :.1 C Stability : ±3 C Emissivity :.99 (±.1) Controlling Sensor : Pyrometer Method of Control : Digital self tuned advanced PID Controller Time to Reach Max Temp. : 2 Mins Heater Size : 1 x 15 x 3 mm Power Required : 44 VAC, 12KW Dimension : 9(L) x 6(W) x 44(H) mm Insert Gas : Argon Gas Mounting Arrangement For Fast Cal : SS Trolly with in Built water tank. pump and other accessories Weight : Approx 85 Kg Optional available upto 3 C also.
25 CalREF Reference Unit CRCA BOX FRP BOX CalREF CalREF 6 C Thermoelectric reference unit 6 C Thermoelectric reference unit Eliminates Old Fashioned Ice Bath Versatile use in industries, Laboratories, Instrument shop Versatile use in factory, Laboratory, Instrument Shop Rugged Outer case for safe Portability NABL Traceable Calibration Available NABL Traceable Calibration Available Reference Junction Temperature : C (Standard) Types of T/C : J, K, T, E, N, R, S, B Accuracy : ±.1 C, Errors can be compensated by adjusting controller setting Stability : ±.3 C Stabilization Time : 15 Mins Capacity : 2 No (User Defined) Resolution : ±.1 C Dimension : 315(H)x35(W)x332(D) mm Weight : 13Kgs Power Supply : 23 VAC, 5 Hz Carry case : Aluminium modular box As per customer requirement from -15 to +9 C Temperature Range : Ambient +1 to 9 C Types of T/C : J, K, T, E, N, R, S, B Accuracy : ±.5 C, Errors can be compensated by adjusting controller setting Stability : ±.5 C Stabilization Time : 1 Mins Capacity : 6-24 Channel (Max. Capacity : 48 Channel) Resolution : ±.1 C Dimension(CRCA) : 35(H) x 35(W) x 21(D) mm Dimension(FRP) : 33(H)x33(W)x18(D) mm Weight : 15Kg(CRCA), 1Kg(FRP) Power Supply : 23 V AC, 5/6 Hz / 24 V DC
26 Product Index 1 Metal sheath Standard Platinum Resistance Thermometer(SPRT) - AM Quartz sheath SPRT - AM 195/ Metal Sheath SPRT - AM 185/ Semi Standard PRT (SSPRT) 6 5 Master PRT 7 6 Nobel Metal Master Thermocouple 8 7 Nobel Metal Master Thermocouple with cold junction compensation 9 8 Secondary Thermocouple 1
27 Metal Sheath Platinum Resistance Thermometers (SPRTs) - AM Main Application Am188 Standard Platinum Resistance Thermometers (SPRT) interpolates temperature in the range from - 2 C to 67 C on the International Temperature Scale of 199 (ITS-9). The sensing element and sensor support adopt a Bird-Cage design and they are protected inside a platinum capsule. Compared to the traditional coil wounding method, the Bird-Cage handles mechanical shocks much better at the same time allows for high purity platinum wire to be wound strain-free. The platinum capsule protects the sensing element from contaminations at high temperature. 1.2 Main Features Ÿ Bird-Cage design to make it mechanical shocks resistant Ÿ Platinum Capsule to protect sensor from high temperature contaminations Ÿ Metal Sheath for harsh environment Ÿ Temperature range: -2 C to 67 C Ÿ 5.56mm diameter for quick response 1.3 Specifications Temperature Range -2 C to 67 C Rtpw Resistance Ratio Drift at.1 C* Nominal 25.5 Ω W(Ga)>=1.1187, W(Hg)<= ΔR(.1 C ) <.6 C/year,.3 C/year typical Repeatability <.1 C Thermal Shock Self-heating Measurement Current Sensor Length Insulation Resistance Sheath Material Dimension External Leads Termination Handle Dimension Carrying Case <.1 C after 1 times thermal cycles from minimum to maximum temperatures <.15 C at 1 ma current 1 ma 42 mm >1 MΩ at room temperature Inconel 5.56 mm (OD) X 5 mm (L) Insulated copper wire, 4 leads, 2.5 meters Gold-plated Spade 21mm (OD) X 8 mm (L) Included
28 Quartz Sheath Standard Platinum Resistance Thermometers (SPRTs) 1.1 Main Application SPRT are used to interpolate temperature in the range from C to C on the International Temperature Scale of 199 (ITS-9). They are widely used as standard or reference thermometers to calibrate other thermometers and to measure temperature precisely in primary and secondary laboratories. AM195 and AM196 SPRTs are the crown jewels of AccuMac temperature probes. It takes decades of scientific expertise and original craftsmanship to create these world class products. They feature a very low drift rate. AM195 has a temperature range from -2 C to 5 C. AM196 covers range from -2 C to 67 C. 1.2 Main Features Ÿ Affordable Standard Platinum Resistance Thermometer (SPRT) Ÿ Extremely low drift rate Ÿ Temperature range : -2 C to 67 C 1.3 Specifications Temperature Range 195 : -2 C to 5 C, 196 : -2 C to 67 C Rtpw Resistance Ratio Drift at.1 C* Repeatability Thermal Shock Self-heating Measurement Current Sensor Length Insulation Resistance Sheath Material Dimension External Leads Termination Handle Dimension Calibration (Optional) Nominal 25 Ω W(Ga)>= W(Hg)<= ΔR(.1 C) <.2 C/1 hours at 5 C ΔR(.1 C) <.4 C/year 196 ΔR(.1 C) <.3 C/1 hours at 67 C ±.1 C ±.1 C after 1 times thermal cycles from minimum to maximum temperatures.15 C at 1mA current 1 ma 42mm >1 MΩ at room temperature Fused-Quartz 195 : 7 mm (OD) X 48 mm (L) 196 : 7 mm (OD) X 5 mm (L) Insulated copper wire, 4 leads, 2.5 meters Gold-Plated Spade 21mm (OD) X 8 mm (L) 5 Fixed Point Calibration at Tempsens NABL Accredited Lab with ITS 9 Constants and Resistance Vs Temperature Chart in 1 C increment
29 Metal Sheath Standard Platinum Resistance Thermometers (SPRTs) 1.1 Main Application Standard Platinum Resistance Thermometers (SPRTs) are common used to interpolate temperature in the range from C to C on the International Temperature Scale of 199 (ITS-9). They are widely used as standard or reference thermometers to calibrate other thermometers and to measure temperature precisely in primary and secondary laboratories. AM185 and AM186 SPRTs are the crown jewels of AccuMac temperature probes. It takes decades of scientific expertise and original craftsmanship to create these world class products. They feature a very low drift rate. AM185 has a temperature range from - 2 C to 5 C. AM186 covers range from -2 C to 67 C. They are widely used as reference thermometer at drywell block calibrator and temperature bath. 1.2 Key Features Ÿ Metal sheathed Ÿ Great reference thermometer for dry block calibrators Ÿ Temperature range : -2 C to Specifications Temperature Range 185 : -2 C to 5 C, 186 : -2 C to 67 C Rtpw Resistance Ratio Drift at.1 C* Repeatability Thermal Shock Self-heating Measurement Current Sensor Length Insulation Resistance Sheath Material Dimension External Leads Termination Handle Dimension Nominal 25 Ω or nominal 1 Ω W(Ga)>= W(Hg)<= ΔR(.1 C) <.2 C/1 hours at 5 C ΔR(.1 C) <.8 C/year 186 ΔR(.1 C) <.3 C/1 hours at 67 C ΔR(.1 C) <.1 C/year ±.15 C ±.15 C after 1 times thermal cycles from minimum to maximum temperatures.15 C at 1mA current 1 ma 42 mm >1 MΩ at room temperature Inconel 185 : 6.35 mm (OD) X 48 mm (L) 186 : 6.35 mm (OD) X 5 mm (L) Insulated copper wire, 4 leads, 2.5 meters Gold-plated Spade 21mm (OD) X 8 mm (L) Calibration (Optional) 5 Fixed Point Calibration at Tempsens NABL Accredited Lab with ITS 9 Constants and Resistance Vs Temperature Chart in 1 C increment
30 Semi Standard PRT (SSPRT) 1.1 Main Application SSPRT provides an affordable alternative for precision temperature measurement and calibration in labs & fields. Metal Sheathed Semi Standard Platinum Resistance Thermometer are widely used as a reference to calibrate various temperature probes, particularly in secondary calibration laboratories. 1.2 Main Features Ÿ Low Drift Ÿ Cost effective Ÿ Temperature range :- 2 C to 67 C SSPRT is constructed with a 6 mm outer diameter metal sheath of high durability. Inside the sheath, the sensing element is protected to shield the sensor from contamination by free floating metal ions found within metal environment at high temperatures. The electrical configuration is a four wire current potential hookup to eliminate effect of lead wire resistance. A special powder mixture is filled into the sensor capsule to support the element wire to protect the element from mechanical shocks. The element is housed in a special protective Assembly to ensure minimum drift over long term use. L Ex. Ordering Code : Model - Dia - Length - Extension Cable Length SSPRT Specifications Model SSPRT Make Tempsens Resistance at C 1 ±1Ω Temperature Coefficient.385 Ω/ Ω/ C Temperature Range -2 C to 67 C Sheath Material Inconel 6 Drift ±3m C at C after 1 hours at 66 C Dimension Extension leads Short Term Stability (6. mm X 45 mm) 1.5 mtr. long teflon Insulated silver plated copper cable with gold plated spade.1 C Handle Dimension 15 mm (OD) X 1 mm( L) Calibration (Optional) 5 Fixed Point Calibration at Tempsens NABL Accredited Lab with ITS 9 Constants and Resistance Vs Temperature Chart in 1 C increment 6
31 High Accuracy PRT 1.1 Main Application High accuracy Platinum Resistance Thermometer (PRT) is an interpolating instrument converting temperature to resistance. It works together with readout device to measure temperature or change of temperature. It has wide applications for dry-wells or temperature baths. 1.2 Main Features Ÿ High accuracy : Refer specification Ÿ Temperature range : Refer specification Ÿ Durable and shock resistance 1.3 Calibrations It is recommended to calibrate this PRT annually over the full temperature range in between annual calibrations, user can check the drift rate by comparing Rtpw against the last Calibration results. Refer to specifications section for normal drift rate. 1.4 Ordering Code Model Dia* L Length* Extension cable length* TPRT(XXX) (X.X) mm (XXX) mm (XX) Mtr Example : TPRT * Can be provided as per customer requirement 1.5 Specifications Make Resistance at C Tempsens Nominal 1 Ω Temperature Coefficient.385 Ω/ Ω/ C Sheath Material Dimension Extension leads Temperature Range SS-316 Model TPRT 11 Drift (6. mm X 45 mm) 1.5 mtr. long teflon Insulated silver plated copper cable with flying leads Handle Dimension 15 mm (OD) X 1 mm( L) Calibration Standatd Short Term Stability Accuracy at 5 points at Tempsens NABL Accredited Lab.1 C -38 to 25 C(1/1 Din) ±.3 C at C after 1 hours at 25 C ±.4 C at -38 C ±.3 C at - C ±.8 C at 1 C ±.13 C at 2 C ±.155 C at 25 C.1 C -38 to 25 C(1/5 Din) TPRT 15 ±.5 C at C after 1 hours at 25 C ±.1 C at - 38 C ±.6 C at C ±.16 C at 1 C ±.26 C at 2 C ±.31 C at 25 C.2 C -8 to 3 C(1/3 Din) -8 to 4 C(Class A) TPRT 13 TPRT 1 ±.7 C at C after 1 hours at 25 C ±.23 C at -8 C ±.1 C at - C ±.27 C at 1 C ±.43 C at 2 C ±.6 C at 3 C.2 C ±.1 C at C after 1 hours at 25 C ±.31 C at -8 C ±.15 C at C ±.35 C at 1 C ±.65 C at 25 C ±.95 C at 4 C 7
32 Nobel Metal Master Thermocouples 1.1 Main Application Tempsens offers special Reference thermocouples for high temperatures upto 15 C for highly accurate temperature measurement. These Thermocouples are offered in platinum / Rhodium (type R, S or B) elements with a high purity Alumina insulations and sheath materials. Thermocouples employing platinum in combination with platinum-rhodium alloys have been found to be the most reproducible of all the various types. They are resistant to oxidation in air and, because of their high melting points, can be used at very high temperatures. The best-known member of this group is the Type S (Pt1Rh/Pt) or Type R (Pt13Rh/Pt). It was long considered more accurate and has probably been studied more than any other thermocouple. The performance of Type R or Type S thermocouple depends strongly on the annealing process, materials used, and other construction techniques. L 1.2 Ordering Code Model Dia* Length* Extension cable length* TTC(X) (X.X) mm (XXX) mm (XX) Mtr. R S Example : TTCS * Can be provided as per customer requirement 1.3 Specifications Make No. of Element Tempsens Simplex Temperature Range to 15 C Sheath Material Sheath length Extension Cable Sheath Dia Alumina ( 99.7 % pure Al2O3) 45 mm 1.5 mtr. Long Teflon insulated cable with male/female miniature connector 6 mm Handle Dimension 15 mm (OD) X 1 mm( L) Calibration Accuracy at 5 points at Tempsens NABL Accredited Lab Special Class (.6 C or.1 % of temperature whichever is greater) Model Type TTCS S(Pt1%Rh/Pt) TTCR R(Pt13%Rh/Pt) 8
33 PTRH Master Thermocouples with Cold Junction Compensation 1.1 Main Application Tempsens offers special Reference thermocouples for high temperatures upto 15 C for highly accurate temperature measurement. These Thermocouples are offered in platinum / Rhodium (type R, S or B) elements with a high purity Alumina insulations and sheath materials. The Cold junction compensation probe provides much accurate temperature measurement possibilities. The cold junction probe is inserted into Ice water mixture. This is necessary for precision measurement. 1.5 Mtr long teflon insulated copper wire SS316 1Mtr long original PTRH wires with sleeve L 1.2 Ordering Code Model Dia* Length* Extension cable length* TTC(X)CJC (X.X) mm (XXX) mm (XX) Mtr. R S Example : TTCSCJC * Can be provided as per customer requirement 1.3 Specifications Make No. of Element Tempsens Simplex Temperature Range to 15 C Sheath Material Cold Junction Sheath Sheath length Extension Cable Sheath Dia Alumina ( 99.7 % pure Al2O3) Stainless Steel Dia : 4.5 mm, Length : 25 mm 45 mm 1.5 mtr. Long Teflon insulated cable with flying leads 6 mm Handle Dimension 15 mm (OD) X 1 mm( L) Calibration Accuracy at 5 points at Tempsens NABL Accredited Lab Special Class (.6 C or.1% of temperature whichever is greater) Model Type TTCRCJC R(Pt13%Rh/Pt) TTCSCJC R(Pt1%Rh/Pt) 9
34 Secondary Thermocouple 1.1 Main Application K type and N type Thermocouple is mainly use in Industries as a secondary master sensor. It works together with readout device to measure Temperature or change of temperature. It has wide applications for dry-wells or temperature baths. 1.2 Main Features Ÿ Good accuracy :.4% of reading at 1.1 C of temperature, whichever is higher Ÿ Temperature range : C to 12 C 1.3 Calibrations It is recommended to calibrate this Thermocouple annually over the full temperature range. L 1.4 Ordering Code Model Dia* Length* Extension cable length* TTC(X) (X.X) mm (XXX) mm (XX) Mtr. K N Example : TTCK * Can be provided as per customer requirement 1.5 Specifications Make No. of Element Tempsens Simplex Temperature Range to 12 C Sheath Material Inconel 6 Sheath length Extension Cable Sheath Dia 4 mm 1.5 mtr. Long Teflon insulated cable with male female miniature connector 6 mm Handle Dimension 15 mm (OD) X 1 mm( L) Calibration Accuracy at 5 points at Tempsens NABL Accredited Lab Special Class (1.1 C or.4% of temperature whichever is greater) Model Type TTCK CR/AL K Type TTCN NI-CR-SI/N Type 1
35 TEMPMET Tempmet is a special high precision thermometer specially made for temperature calibration labs. The unmatched resloution of.1 C and sturdy working makes it a labortary workhouse. TEMPMET 8 - RTD + THERMOCOUPLE Specifications RTD + T/C type RTD + T/C range Accuracy Pt1 K S E -2 C ~ +85 C ±.5 C C ~ 1768 C ±2.4 C T -2 C ~ +4 C ±1.2 C J -2 C ~ C ±1.5 C -2 C ~ +1 C ±1.2 C -21 C ~ +12 C ±1.2 C R C ~ C ±2.4 C B 3 C ~ +182 C ±2.4 C N -2 C ~ +13 C ±1.8 C Operation Temperature and Humidity : C ~ 5 C, <8% RH Storage Temperature and Humidity : -1 C ~ 6 C, <7% RH Power Requirement : (AA Size) bayyeries, up to 15 hours of continuous work time Input Protection at Thermocouple Input : 24V AC/DC Maximum Dimension(Without holster) : 115 mm X 7 mm x 3 mm (LxWxH) Weight : Approx..25 Kg (Include Battery) Model No. : C 31 Accuracy of RTD Measurement :.1 C Accuracy of T/C Measurement :.1 C Resolution of RTD :.1 C Resolution of T/C :.1 C Measuring Input : 2 Channel T/C Input : Type B, E, J, K, N, R, S, T RTD Input : PT 1 Units : C, F, Ohm Data Logging : 685 valves Digital Communication : RS Battery : Rechargeable Type TEMPMET 9 - RTD + THERMOCOUPLE Specifications RTD + T/C type RTD + T/C range Accuracy Pt1-2 C ~ +85 C ±.2% RDG +.6 C Pt1-14 C ~ +32 C - Cu5-5 C ~ +15 C ±.8 C Cu1-5 C ~ +15 C ±.6 C Ω -. ~ 22 Ω ±.2% RDG +5mΩ mv -1. ~ +2.mV ±.15% RDG +1µV ma -2. ~ +24.mA ±.3% RDG +3µA K -2 C ~ C ±.5 C S -. ~ 1768 C ±.8 C E -2 ~ +1 C.4 C T -2 ~ +4 C ±.5 C J -21 ~ +12 C ±.5 C R. ~ 1768 C ±.8 C B 3 ~ +182 C ±.9 C N -2 ~ +13 C ±.5 C Operation Temperature and Humidity : C ~ 5 C, <8% RH Storage Temperature and Humidity : -1 C ~ 6 C, <7% RH Power Requirement : (AA Size) batteries, up to 15 hours of continuous work time Input Protection at Thermocouple Input : 24V AC/DC Maximum Dimension(Without holster) : 115 mm X 7 mm x 3 mm (LxWxH) Weight : Approx..25 Kg (Include Battery) INPUT Thermocouple RTD Unit Resolution : K, S, E, T, J, R, B, N : Pt1 : C, F, K :. C/. F INPUT Thermocouple RTD mv ma Resistance Unit Resolution : K, S, E, T, J, R, B, N : Pt1, Cu5, Cu1 : -1 to 2mV : -2 to 24 mv : to 5 Ohms : Ohms, ma, mv, C, F, K :. C/. F,. A/V/mA/mV
36 CALIBRATION SERVICES Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. It is the only private sector company in the country with accredited Fixed Point Temperature calibration Laboratory. The lab has highly stable calibration furnaces, measuring instruments and accurate master sensors traceable to National and international Standards. The calibration center functions as per ISO1725/NABL standards. Calibration of contact type sensors can be made in temperature range of -196 C to 16 C and Calibration of non contact type sensors can be made in temperature range C to 17 C. Further the laboratory offers both in house and on site temperature calibration. In House Calibration Facility In house calibration facility for contact and non contact type sensor traceable to National and International standards. Best Measurement Capabilities and temperature range is as shown in table Fixed Point Calibration Facility Quality Measured/Instruments Calibration of SPRT/PRTS/ THERMOCOUPLES at Quality Measured / Instruments Contact Type RTD, Thermocouples Thermometers Non Contact Type Pyrometer Temperature Range -196 C -8 to -38 C -38 C to C > C to 14 C >14 C to 25 C >25 C to 65 C >65 C to 1 C >1 C to 12 C >12 C to 16 C Temperature Range Triple Point of Water (.1 C) C to 25 C >25 C to 4 C >4 C to 5 C >5 C to 15 C >15 C to 17 C Melting Point of Gallium ( C) Freezing Point of Tin ( C) Freezing Point of Zinc ( C) Freezing Point of Aluminum ( C) Calibration & Measurement Capability.5 C.7 C.3 C.3 C.4 C.12 C 1.2 C 1.6 C 3.4 C We are first private company to provide fixed point temperature calibration for Triple point of water (Tpw), Gallium (Ga), Tin (Sn), Zinc (Zn) & Aluminum (Al) Cells. Fixed points are most accurate devices available for defining a temperature scale. Fixed point cells are designed to realize the liquid-solid equilibrium temperatures of certain high purity metal elements, for calibration of thermometers at ITS-9 fixed points. The best measuring capability and Temperature range for fixed point calibration is shown in table Unique Advantages One of the best Labs in India equipped with various type of calibration furnaces and measuring instruments. Fixed point cells calibration. One of the best B.M.C. NABL Accreditation Provide on-site calibration Prompt and Fast Services Covers wide range -8 C to 16 C with NABL Certificate. (17 C without NABL certificate is also possible.) C 1. C 2. C 2.5 C C Calibration & Measurement Capability.4 C.85 C.85 C.9 C.9 C
37 Always one step ahead Committed to success TEMPSENS Instruments (I) Pvt. Ltd is a part of Pyrotech group which was established by four technocrats in 1976 at Udaipur, with our first product as Thermocouples and RTDs. To enhance our customer's success we provide high quality products and services for "Temperature solution", tailored to their needs, and delivered to meet their schedule. We have tied up with world leaders in Temperature measuring technology for critical components, Non contact Temperature measurement and Thermal imaging solutions. We add value to these products and deliver complete engineered solutions, backed by efficient service and application support. Today we have strong sales and service network operating from important locations of India and abroad. Continuing our constant endeavor of delivering solutions for temperature technology to our large base of over two thousand satisfied customers. 35 years of experience. Large Customer base. Other Products Ÿ Thermocouples Ÿ RTDs Ÿ Cables Executed Major Projects in India and Abroad. Production Expertise- Specialized Team & Facility. Ÿ Thermowells Ÿ Industrial Heaters Ÿ Non Contact Pyrometers Ÿ Furnace monitoring Camera Ÿ Thermocouple Accessories Ÿ Industrial Furnances w w w. t e m p s e n s. c o m INDIA Tempsens Instruments (l) Pvt. Ltd. U# l B-188A, Road No.5, M.I.A,. Udaipur-3133 (Rajsthan) INDIA Ph.: to 8 Fax.: info@tempsens.com Tempsens Instruments (l) Pvt. Ltd. U# ll A-19, Road No.5, M.I.A,. Udaipur-3133 (Rajsthan) INDIA Ph.: Fax.: info@compensatingcables.net info@tempsens.com GERMANY Tempsens Instruments GmbH Loehestrasse 37, Hennef, GERMANY Ph.: Fax.: hmueller@tempsens.de CHINA WUXI Tempsens Instruments Co. Ltd. Rm 911,ShiDaijieDou, No.655, Hubin Rd., Binhu District, Wuxi, Jiangsu, CHINA Ph.: Fax.: sophia@tempsens.com
AM1880 Standard Platinum Resistance Thermometer User s Guide
AM1880 Standard Platinum Resistance Thermometer User s Guide Please download the latest version at www.accumac.com Rev. 201609V3 Table of Contents Before you start ---- Please read to avoid possible warranty
More informationReference thermometer Model CTP5000
Calibration technology Reference thermometer Model CTP5000 WIKA data sheet CT 61.20 Applications Reference thermometer for measuring very accurate temperature in a range of -196... +660 C [-321... +1,220
More informationA High-Quality Platinum Resistance Thermometer to 661 C
A High-Quality Platinum Resistance Thermometer to 661 C Presenter: Mingjian Zhao 799 East Utah Valley Drive American Fork, UT 843-9775 Phone: (81) 763-16 Fax: (81) 763-11 E-mail: mingjian_zhao@hartscientific.com
More informationRealization of ITS-90 from K through K: One Company s Approach
Realization of ITS-90 from 273.15 K through 1234.93 K: One Company s Approach Xumo Li, Steve Iman, Mike Hirst, Mingjian Zhao Hart Scientific, Inc. Abstract All of the fixed points of the International
More informationAM1730 Secondary Reference Platinum Resistance Thermometer User s Guide
AM1730 Secondary Reference Platinum Resistance Thermometer User s Guide Please download the latest version at www.accumac.com Rev. 201609V3 Table of Contents Before you start ---- Warnings & Cautions...
More informationAM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide
AM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide 1/11 Table of Contents Before you start ---- Warnings & Cautions... 3 1 Introduction... 4 1.1 Main Application... 4 1.2 Main
More informationAM1620 Precision Industrial Platinum Resistance Thermometer User s Guide
AM1620 Precision Industrial Platinum Resistance Thermometer Table of Contents Before you start ---- Warnings & Cautions... 2 1 Introduction... 3 1.1 Main Application... 3 1.2 Main Features... 3 1.3 Calibrations...
More information4 RESISTANCE THERMOMETRY
4.1 4 RESISTANCE THERMOMETRY PRINCIPLES AND APPLICATIONS OF RESISTANCE THERMOMETERS AND THERMISTOR Resistance thermometers and Thermistor are temperature sensors, which changes there electrical resistance
More informationMineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths
Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable
More informationSURFACE TEMPERATURE SENSORS
SURFACE TEMPERATURE SENSORS These sensors are thermocouples and resistance thermometers for surface temperature measurement of objects. C400 R400 Magnet sensors measurement and monitoring of objects such
More informationENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead
ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead (Image shows 4 wire) Pt1000 element to IEC 751 Class B 2 wire configuration Temperature range -50 C to + 200 C Pt1000
More informationDatasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths
Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This
More informationPlatinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves
ENGLISH Datasheet Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves Pt100 Autoclave & steriliser drain temperature probe For use to monitor the fluid
More informationCompact flue gas analyser: testo 300 M-I
220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial
More informationPlatinum Resistance Thermometer (PRT) Selection Guide
Platinum Resistance Thermometer (PRT) Selection Guide hken.rs-online.com (Hong Kong (English)) www.rs-components.com (International) Thermocouple & Platinum Resistance Thermometry - At A Glance Discover
More informationTEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS
TEWA TEMPERATURE SENSORS TEWA TERMICO ul. ul.litewska 14, 21-010 Łęczna, THE COMPANY PROFILE EXPERIENCE is a leading NTC Thermistor and Temperature Probe manufacturer located in Lublin, serving the European
More informationCeramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code
Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641
More informationThermocouple cable and assemblies ENCLAD
Thermocouple cable and assemblies ENCLAD ENCLAD thermocouples Introduction BASF ENCLAD thermocouple products are a precise and rigorously controlled combination of select precious and base metal sheaths,
More informationThermocouple for Flue Gas Temperature Measurements,
Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and
More informationMetal Transitions HIGH TEMPERATURE
Metal Transitions High Temperature Thermal Solutions of Texas continues to meet the demands of technological advances by developing thermocouples using materials with unusually high performance characteristics
More informationENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead
Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat
More informationSpecifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)
ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or
More informationPlatinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing
Datasheet ENGLISH Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Pt100 Patch Sensor (100 Ω Ohms @ 0
More informationENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)
ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,
More informationFurnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing
Furnaces for Research and Laboratory Testing Drying Ashing Tempering Preheating Sintering Firing Annealing Muffle Furnaces KL 03/11 KL 15/12 T max 1100 C and 1200 C Universal muffle furnaces for many laboratory
More informationCH88 In Situ Flue Gas Oxygen Transmitter
CH88 Combustion Flue Gas Oxygen Analyzer System CMB-PDS-CH88 Product Data Sheet September 2017 CH88 In Situ Flue Gas Oxygen Transmitter World-Class TM performance Outstanding accuracy ±1% full scale 1056
More informationENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting
ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting RJT unions (Ring Joint Type) are often referred to as a standard union. The compromise of an O-ring style gasket
More informationMeasurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum
Measurement & Analytics Measurement made easy AlSCAN TM and AlSCAN TM Argon Today s global economy and competition have compelled aluminum producers and aluminum foundries to produce the highest possible
More informationENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)
ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code) Versatile, high quality, circuit board mounting miniature socket Specially designed
More informationTemperature Measurement and Control
Temperature Measurement and Control What is the definition of temperature? Correlates to molecular kinetic energy Measure of the quality of heat Reference material http://www.omega.com/temperature/z/zsection.asp
More informationMGO INSULATED THERMOCOUPLES INDEX
MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,
More informationProven Capabilities. Features and Benefits. Watlow provides:
Proven Capabilities Since 1914, SERV-RITE thermocouple wire and thermocouple extension wire from Watlow have been known for premimum performance and reliability. All SERV-RITE wire is manufactured under
More informationCarbon film resistors
Carbon film resistors (6.3 φ 2.4 size: 1 / 3W) ROHM resistors are produced using an integrated production system for parts and materials, and state of the art technology to ensure high precision productivity,
More informationTHE INFRARED PROS. Non Contact Infrared Thermometers for the Glass Industry
THE INFRARED PROS Non Contact Infrared Thermometers for the Glass Industry The Glass Industry Glass manufacturing was one of the first industries to use non-contact temperature measurement. Many of today
More informationTHERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples
THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples Figure 2: Mineral Oxide Thermocouples Figure 3: Thermoresistances GENERAL CHARACTERISTICS
More informationYSI Precision Thermistors & Probes
YSI Precision Thermistors & Probes Introduction Thermistor Components Special Test Services Configure to Order Probes YSI 400 and 700 Series Reusable Probes YSI 4600 Precision Thermometers Technical Information
More informationTemperature Calibration
Temperature Calibration Technical Data Temperature plays a key role in many industrial and commercial processes. Examples include monitoring cooking temperature in food processing, measuring the temperature
More informationMEHRAN UNIVERSITY OF ENGINEERING AND TECHNOLOGY, JAMSHORO Sensors & Actuator for Automatic Systems LAB # 01 RESISTIVE TEMPERATURE TRANSDUCERS
MEHRAN UNIVERSITY OF ENGINEERING AND TECHNOLOGY, JAMSHORO Sensors & Actuator for Automatic Systems LAB # 01 RESISTIVE TEMPERATURE TRANSDUCERS Roll No: Checked by: Date: Grade: 1. Objectives: To determine
More informationDEVELOPMENT OF DURABLE GOLD VERSUS PLATINUM THERMOCOUPLES
XVIII IMEKO WORLD CONGRESS Metrology for a Sustainable Development September, 17 22, 2006, Rio de Janeiro, Brazil DEVELOPMENT OF DURABLE GOLD VERSUS PLATINUM THERMOCOUPLES Masahiko Gotoh 1, Hideaki Oikawa
More informationInternational Thermocouple and Extension Grade Wire Color Codes
International Thermocouple and Extension Grade Wire Color Codes ANSI Code Alloy Combination + Lead - Lead Color Coding Thermocouple Extension Grade Grade Maximum Useful Range ++ Maximum Thermocouple Grade
More informationtemperature calibration equipment & services
blackbody sources The Florentine Thermometer ISSUE 5 & thermocouple reference equipment temperature calibration equipment & services CONTENTS The Hyperion R Calibration Bath comprises a blackbody Introduction:
More informationThermocouples and Accessories Product Catalog
Thermocouples and Accessories Product Catalog 7282 N. Haggerty Rd. Canton, MI 48187 P. 734-451-8740 / F. 734-451-8741 www.inspec-inc.com 1 P a g e EXPERT CONTROL AND INSTRUMENTATION REPAIR Plastics Industry
More informationWATER QUALITY TESTER. MIC water quality tester standard packing : More MIC water quality combo testers
WATER QUALITY TESTER 99702 99720 99701 99703 MIC water quality tester standard packing : 99601 ph : ph meter, two calibration solutions, one soaking solution,battery CR2032 and screw driver are installed
More informationWelding Processes. Consumable Electrode. Non-Consumable Electrode. High Energy Beam. Fusion Welding Processes. SMAW Shielded Metal Arc Welding
Fusion Consumable Electrode SMAW Shielded Metal Arc Welding GMAW Gas Metal Arc Welding SAW Submerged Arc Welding Non-Consumable Electrode GTAW Gas Tungsten Arc Welding PAW Plasma Arc Welding High Energy
More informationHIGH TEMPERATURE FURNACES. High Temperature Chamber Series High Temperature Tube Series High Temperature Elevator Series
HIGH TEMPERATURE FURNACES High Chamber Series High Tube Series High Elevator Series Chamber Furnaces MoS Series MoS series have been used as trusted professional chamber furnaces for many years in laboratories.
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE
SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE C20 C21 C26-2 C26-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration
More informationRAMA CORPORATION RAMA CELL HEATERS ESTABLISHED 1947
RAMA CORPORATION RAMA CELL HEATERS ESTABLISHED 1947 RAMA CORPORATION INNOVATION THROUGH EXPERIENCE 600 WEST ESPLANADE AVE SAN JACINTO CA 92583 TELEPHONE: 800.472.5670 FAX: 866.255.4414 EMAIL: SALES@RAMACORPORATION.COM
More informationELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE
ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE Introduction The ability of materials to conduct electric charge gives us the means to invent an amazing array of electrical and electronic devices,
More information7. EXTENSION LEADS AND COMPENSATING CABLE
7. EXTENSION LEADS AND COMPENSATING CABLE 7.1 INTRODUCTION : It is often desirable to connect a thermocouple probe, as a part of a very long circuit from the sensor itself to a remote reference unit and/or
More informationTemperature Sensors. The Watlow Educational Series Book Four
Temperature Sensors The Watlow Educational Series Book Four Temperature Sensors Objectives........................................................3 Introduction......................................................3
More informationAnalytical Instruments
Smart Sensors Unique measurement technology Unique Innovations Honeywell is an industry proven leader for analytical products and solutions with unique technologies. Innovations in analytical measurements
More informationTEMPERATURE SWITCHES AND THERMOSTATS
TEMPERATURE SWITCHES AND THERMOSTATS Our temperature switches and thermostats are ideal for applications where the end user is looking for highly accurate control across a wide range of operating temperatures.
More informationTemperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!
JC Series High Performance Controllers...at the lowest prices anywhere! Structure Units available in standard DIN sizes (1/16, 1/8, and 1/4 DIN) NEMA 4X protective construction Black enclosure Programmable
More informationPerkin Elmer HGA-600/ HGA-700 Graphite Furnaces
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces The HGA-600 and HGA-700 are
More informationThermocouple Quick Reference Guide. Aluminium Temperature Sensing Solutions from the Smelter to the Foundry
Thermocouple Quick Reference Guide Aluminium Temperature Sensing Solutions from the Smelter to the Foundry why pyrotek? Pyrotek is a global engineering leader and innovator of technical solutions, integrated
More informationConstruction of a Seebeck Envelope Calorimeter and Reproducibility of Excess Heat
Zhang, W.-S., J. Dash, and Z.-L. Zhang. Construction of a Seebeck Envelope Calorimeter and Reproducibility of Excess Heat. in ICCF-14 International Conference on Condensed Matter Nuclear Science. 2008.
More informationSolar Flat Plate Thermal Collector
Solar Flat Plate Thermal Collector 1 OBJECTIVE: Performance Study of Solar Flat Plate Thermal Collector Operation with Variation in Mass Flow Rate and Level of Radiation INTRODUCTION: Solar water heater
More informationINDUSTRIAL THERMOMETERS
JJ SIKA thermometers for industry and marine sector JJ Special versions and accessories JJ SIKA thermometers for heating, air conditioning and ventilation (HVAC) INDUSTRIAL THERMOMETERS Contains products
More informationENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)
ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code) Range of miniature thermocouple connectors with flat pins to suit thermocouple type Ideal
More informationMulti-function VAC measuring instrument
Data sheet testo 480 Multi-function VAC measuring instrument testo 480 Cutting-edge technology for professionals Measurement of all VAC-relevant parameters: flow velocity, temperature, humidity, pressure,
More informationThis Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /
This Specification Data Sheet brought to you by: 15825 Trinity Blvd. Fort Worth, Texas 76155 817/465-9494 equipment@technicaldiagnostic.com www.technicaldiagnostic.com www.test-equipment-rental.com The
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS
SPRING LOADED THERMOCOUPLE CONFIGURATIONS FOR USE WITH THERMOWELLS II 3G Ex na/nl TCRN/WN/TN S30 S31 S36-1 S36-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration guarantees
More informationAS950 ALL-WEATHER REFRIGERATED SAMPLER
AS950 ALL-WEATHER REFRIGERATED SAMPLER Applications Wastewater Collection systems Industrial pretreatment Environmental monitoring Stormwater Sampling has never been this easy. Hach's AS950 sampler controller
More informationEVERYTHING YOU WANTED TO KNOW ABOUT PYROMETERS.
EVERYTHING YOU WANTED TO KNOW ABOUT PYROMETERS. David Coggins - dcoggins47@gmail.com INDEX 1.0 Introduction 2.0 General Principles 3.0 Thermocouples 3.1 Type R Thermocouples 3.2 Type K Thermocouples 3.3
More informationBiogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas
MRU over 30 years of innovative gas analysis! Biogas analysers Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas Product overview MRU Biogas analysers Whether biogas, landfill and coal mine
More informationTin-filled multi-entrance fixed point
Tin-filled multi-entrance fixed point D. Zvizdić and D. Šestan Citation: AIP Conf. Proc. 1552, 259 (2013); doi: 10.1063/1.4819550 View online: http://dx.doi.org/10.1063/1.4819550 View Table of Contents:
More informationMultifunction HVAC and IAQ Meter
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 435 Multifunction HVAC and IAQ Meter NEW! The newest technology for temperature,
More informationSensortherm. Digital Pyrometer. Temperature Measurement and Control. com
Sensortherm Digital Pyrometer Temperature Measurement and Control Induction hardening Flame hardening Tempering Forging temperatures Conductive heating Vacuum-melting of metals Non-Contact Temperature
More informationPORTABLE HARDNESS TESTING
Portable Hardness Tester IPX-300 Handheld dynamic metal hardness tester with hardness conversion and automatic position setting. Dynamic hardness testing: quick and reliable Impact device D integrated:
More informationINDUSTRIAL TEMPERATURE SENSORS
Temperature s INDUSTRIAL TEMPERATURE SENSORS Temperature s APPLIED SENSOR TECHNOLOGIES A DIVISION OF UNITED ELECTRIC CONTROLS T E M P S E N S O R - B - 0 2 Temperature s Temperature s index Subject Page
More informationlumasense IMPAC Pyrometers Product Overview Highly Accurate Infrared Thermometers for Non-contact Temperature Measurements
lumasense IMPAC Pyrometers Product Overview Highly Accurate Infrared Thermometers for Non-contact Temperature Measurements LumaSense s IMPAC pyrometers are temperature measurement instruments that operate
More informationExperts in Furnaces. Engineering. Fast and flexible. THERMCONCEPT powerd by innovation
Dental Furnaces Sintering furnaces for Zirkonia Chamber Furnaces for Dental Ceramic Compounds Furnaces for CAD / CAM - Systems Pre-heating Furnaces Muffle Furnaces Model Casting Accessories Experts in
More informationResistance Temperature Detectors (RTD)
Resistance Temperature Detectors (RTD) Style H Connection Head Assembly Connection Head Option A - Aluminum Tip Style F - Flat Tip Head Fitting Option G - ½ NPT Hex Nipple Head Fitting Option A - Fixed
More information4-pocket Electron Beam Evaporator E-Beam Evaporator
4-pocket Electron Beam Evaporator E-Beam Evaporator e - -flux4 multi-pocket e-beam evaporator with shutter and individual flux monitor The new tectra 4-pocket e - -flux4 Mini E-Beam Evaporator extends
More informationTARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring
TARGAS-1 Portable Photosynthesis System Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring TARGAS-1 Main Console CO 2 & H 2 O Gas Analysis The TARGAS-1 console is compact, lightweight
More informationOPERATION MANUAL OPTICAL THERMOMETERS
SITEL Control srl Via Arnesano, 4 20030 Palazzolo Milanese Milano Italia Tel. +39-02-99045994 / Fax +39-02-9101082 e-mail: sitelcontrol@sitelcontrol.it / http://www.sitelcontrol.it OPERATION MANUAL OPTICAL
More informationProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS
ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS ProODO Digital Optical Dissolved Oxygen Meter YSI ODO technology reduces the time required to calibrate and maintain your sensors.
More informationFor Safe and Delicious Water
RESIDUAL CHLORINE ANALYZER 400G NON-REAGENT FREE CHLORINE ANALYZER FC400G 400G RESIDUAL CHLORINE ANALYZER FC400G NON-REAGENT FREE CHLORINE ANALYZER Bulletin 12F01A01-01E www.yokogawa.com/an/ For Safe and
More informationHumidity/temperature measuring instrument
Humidity/temperature measuring instrument testo 645 Highly precise measurements for industry Highly accurate humidity measurement up to ±1 %RH %RH Connection of 2 plug-in probes Measurement of temperature,
More informationIndustrial Thermocouples
Industrial Thermocouples Protection Head Design U Sheath Materials: 304SS, 30SS, 36SS, 32SS, Inconel or Super OMEGACLAD XL U Probe Length 300 mm (2"), 600 mm (24") Custom Lengths Available, Consult Sales
More informationTEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK
TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK Material temperature resistance and product testing Maintaining superior temperature stability Sample conditioning
More informationFGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications
Applications An ex situ zirconium oxide analyzer for excess oxygen measurement in dirty, rugged combustion applications such as: Boilers: all fuels and all types, including marine, recover, and utility
More informationFluke Oscilloscope Calibration Solutions. Helping you measure up to the highest standards
Fluke Oscilloscope Calibration Solutions Helping you measure up to the highest standards Fluke offers more ways to meet your oscilloscope calibration needs If your organization is like most, you are competing
More informationHI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter
HI 98703 EPA Compliant Turbidity Meter HI 93414 EPA Compliant Turbidity and Chlorine Meter SPECIFICATIONS Turbidity (HI 93414 & HI 98703) Range Range Selection ACCESSORIES HI 710005 Voltage adapter HI
More informationDatasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W ppm/ C RS Stock No:
Datasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W -500 +350ppm/ C RS Stock No: 707-8861 Product Details RS Pro axial carbon resistor with ±5% tolerance, provides 1 kω resistance and is power
More informationIC-D3160 Ion Chromatograph
IC-D3160 Ion Chromatograph IC-D3160 ion chromatograph is a new modular design of the high stability of ion chromatograph, combining Analytical Technologies Limited independent research and development
More informationnicrom e l e c t r o n i c
G E N E R A L High Performance Thick Film Resistors C A T A L O G 3 Nicrom Electronic Via Roncaglia CH - 6883 Novazzano SWITZERLAND Phone : ++4 () 9 68 99 86 Fax : ++4 () 9 68 99 86 info@nicrom-electronic.com
More informationHFM Heat Flow Meter Thermal Conductivity Analyzer
HFM Heat Flow Meter Thermal Conductivity Analyzer Introduction An insulating material is a material with low thermal conductivity, which in the construction industry, equipment manufacturing, or the production
More informationFpollutant-free zero air for analytical
Ambient Air Quality Monitoring System AQMS-100 Zero Air Generator PI AQMS-100 provides ultra pure Fpollutant-free zero air for analytical purpose. Remote monitoring and configuration can also be achieved
More informationtesto 350. For emission testing and combustion analysis. Portable Emission Analyzer
testo 350. For emission testing and combustion analysis. Portable Emission Analyzer The testo 350 Portable Emission Analyzer The Standard for Emission Testing and Combustion Analysis Whether you are testing
More informationVersatile Research Heat Exchanger
Versatile Research Heat Exchanger Expandable system accurately simulates a broad range of temperatures, pressures, and flowrates. Ideal for a wide variety of applications, including: Fouling research Heat
More informationModel PM-616 Two-Color Pyrometer Operator s Manual Revision 1.2
Model PM-616 Two-Color Pyrometer Operator s Manual Revision 1.2 Logika Technologies Inc. 2857 Sherwood Heights Dr. Unit 2 Oakville ON, CanadaL6J 7J9 Tel: 905-829-5841 www.logikatech.com Logika Technologies
More informationTHERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials
THERMOMETERS Thermometers are used to measure temperature. PIC stocks a variety of temperature measuring instruments, including bimetals, magnetic thermometers, tridicators and scale thermometers. STANDARD
More informationARC STUD WELDING SYSTEMS
ARC STUD WELDING SYSTEMS ARE complete stud welding systems which weld ARC studs using the ARC stud welding process. CONSIST OF the following items: An ARC stud welding power supply with built-in timer/control
More informationStaying Ahead of the Curve with Advanced Controls Technology By Jason Sanders and Jim Grann, Ipsen USA.
Staying Ahead of the Curve with Advanced Controls Technology By Jason Sanders and Jim Grann, Ipsen USA. Perfecting your thermal processing operations is paramount to producing high-quality products. By
More informationProduct data sheet DUMATHERM N Pro. for the automatic serial determination of NITROGEN
for the automatic serial determination of NITROGEN DUMATHERM N Pro Automated system for fast nitrogen determination acc. to Dumas Technical Data DUMATHERM N Pro Data DUMATHERM N Pro Sample size 0,5 mg
More informationUsing the PPM2 Portable Trace Moisture Transmitter
APPLICATION NOTE 2016_0106 PPM2 Using the PPM2 Portable Transmitter The Model PPM2 Portable analyzer is a compact, cost effective, analyzer specifically designed to continuously measure low levels of moisture
More informationILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma
More informationITS.90THERMOSENSORS. Booklet
ITS.90THERMOSENSORS Booklet EUROTHERM SERIES 2000 The tables in this book should be used with Eurotherm Series 2000 instruments only. For 800 Series, 90 Series, 900 Series and all older instruments use:-
More informationIndustrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series
Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series 70-82-03-14 June 08 Page 1 of 8 Specification Main Overview The specification of an Electrolytic Conductivity Cell requires
More information