Transmitters for general requirements SITRANS P DS III
|
|
- Steven Douglas
- 6 years ago
- Views:
Transcription
1 Siemens AG 0 Technical specifications SITRANS P, DS III Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible operating pressure Lower measuring limit Measuring cell with silicone oil filling Upper measuring limit Output HART Differential pressure and flow Span Maximum operating pressure inh O (... 0 mbar) inh O ( mbar) inh O ( mbar) inh O ( mbar) inh O ( mbar) inh O ( mbar) psi ( bar) inh O ( mbar) inh O ( mbar) inh O ( mbar) inh O ( mbar) psi ( bar) 464 psi (3 bar) 30 psi (60 bar) 609 psi (40 bar) PROFIBUS PA and FOUNDATION Fieldbus Nominal measuring range 8 inh O (0 mbar g) 4 inh O (60 mbar) 00 inh O (50 mbar) 40 inh O (600 mbar) 64 inh O (600 mbar) 000 inh O (5 bar) 435 psi (30 bar) 00 inh O (50 mbar) 40 inh O (600 mbar) 64 inh O (600 mbar) 000 inh O (5 bar) 435 psi (30 bar) Maximum operating pressure 464 psi (3 bar) 30 psi (60 bar) 609 psi (40 bar) -00% of max. span (-33% with 435 psi (30 bar) measuring cell or 0.44 psi (30 mbar a)) 00% of max. span (for oxygen version and inert filling liquid; max. 30 psi g (60 bar g)) Output signal ma Digital PROFIBUS PA and FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 3 ma, factory preset to 0.5 ma or optionally - set to.0 ma Load Without HART communication R B (U H V)/0.03 A in Ω, - U H : Power supply in V With HART communication R B = Ω (SIMATIC PDM) or - R B = Ω (HART Communicator) Physical bus - IEC 658- Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Measuring accuracy Acc. to EN Reference conditions (All error data refer always refer to the set span) Error in measurement and fixed-point setting (including hysteresis and repeatability) Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 5 C (77 F)) r: Span ratio (r = max. span / set span) Linear characteristic % -r 0 (0.009 r+0.07)% - 0 < r 30 ( r+0.07)% -30<r 00 (0.005 r+0.05)% Square-rooted characteristic (flow > 50 %) 0, % -r 0 0. % - 0 < r % Siemens FI0 0 US Edition /07
2 SITRANS P, DS III Siemens AG 0 HART Square-rooted characteristic (flow > %) -r 0 0. % - 0 < r % Long-term drift (temperature change ± 30 C (±5 4 F)) (0.5 r)% every 5 years static pressure max. 05 psi g (70 bar g) PROFIBUS PA and FOUNDATION Fieldbus % every 5 years static pressure max. 05 psi g (70 bar g) 0.9 psi (0 mbar)-measuring cell (0. r) per year 0. per year 0.9, 0.87,.3 and 7.5 psi (50, 600, 600 (0.5 r) per year 0.5 per year and 5000 mbar)-measuring cell Influence of ambient temperature at C ( F) (0.08 r + 0.) % 0.3 % at C and C (0. r + 0.5)%/0 K (Twice the value with 0.5 %/0 K ( F and F) 0.9 psi (0-mbar) measuring cell) Influence of static pressure on the zero point (PKN) (0.5 r)% per 05 psi (70 bar) 0.5 % per 05 psi (70 bar) psi (0 mbar)-measuring cell (0.5 r)% per 464 psi (3 bar) 0.5 % per 464 psi (3 bar) on the span (PKS) 0. % per 05 psi (70 bar) psi (0 mbar)-measuring cell 0. % per 464 psi (3 bar) - Measured Value Resolution of nominal measuring range Rated conditions Degree of protection (to EN 6059) IP65 Temperature of medium Measuring cell with silicone oil filling C ( F) Measuring cell with inert filling liquid C ( F) In conjunction with dust explosion protection C ( F) Ambient conditions Ambient temperature - Digital indicator C ( F) Storage temperature C ( F) Climatic class - Condensation Relative humidity % Condensation permissible, suitable for use in the tropics Electromagnetic Compatibility - Emitted interference and interference Acc. to EN 636 and NAMUR NE immunity Design Weight (without options) 4.5 kg ( 9.9 (lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi or stainless steel precision casting, mat. no Wetted parts materials Seal diaphragm Stainless steel, mat. no..4404/36l or Hastelloy C76, mat. no..489, Monel, mat. no..4360, tantalum or gold Measuring cell filling Silicone oil or inert filling liquid (maximum value with oxigen measurement pressure 740 psi a) (0 bar a)) at 60 C (40 F)) Process connection Female thread ¼-8 NPT and flange connection with mounting thread M0 to DIN 93 or 7 / 6-0 UNF to EN 658 Material of mounting bracket Steel Sheet-steel, Mat. No..0330, chrome-plated Stainless steel Sheet stainless steel, mat. no..430 (SS 304) Power supply U H Supplied through bus Terminal voltage on transmitter V DC V DC in intrinsically-safe mode Separate 4 V power supply necessary - No Bus voltage Not Ex V With intrinsically-safe operation V /08 Siemens FI0 0 US Edition
3 Siemens AG 0 SITRANS P, DS III HART PROFIBUS PA and FOUNDATION Fieldbus Current consumption Basic current (max.) -.5 ma Start-up current basic current - Yes Max. current in event of fault ma Fault disconnection electronics (FDE) available - Yes Certificates and approvals Classification according to PED 97/3/EC PN 3/60 (MWP 464/30 psi) For gases of fluid group and liquids of fluid group ; complies with requirements of article 3, paragraph 3 (sound engineering practice) PN 40 (MWP 609 psi) For gases of fluid group and liquids of fluid group ; complies with basic safety requirements of Article 3, paragraph (appendix ); assigned to category III, conformity evaluation module H by the TÜV Nord. Explosion protection Intrinsic safety "i" PTB 99 ATEX - Marking Ex II / G EEx ia/ib IIB/IIC T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T5; C ( F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw; R i =300Ω FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o =. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Explosion-proof "d" PTB 99 ATEX 60 - Marking Ex II / G EEx d IIC T4/T6 - Permissible ambient temperature C ( F) temperature class T4; C ( F) temperature class T6 - Connection To circuits with values: U H = V DC To circuits with values: U H = V DC Dust explosion protection for zone 0 PTB 0 ATEX Marking Ex II D IP65 T 0 C Ex II / D IP65 T 0 C - Permissible ambient temperature C ( F) - Max. surface temperature 0 C (48 F) - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw, R i = 300 Ω FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.3 W Linear barrier: U o = 4 V, I o = 50 ma, P o =. W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 μh, C i =. nf Dust explosion protection for zone / PTB 0 ATEX Marking Ex II D IP65 T 0 C - Connection To circuits with values: U H = V DC; P max =. W To circuits with values: U H = V DC; P max =. W Type of protection "n" (zone ) TÜV 0 ATEX 696 X Planned - Marking Ex II 3 G EEx na L IIC T4/T5/T6 - Explosion protection acc. to FM Certificate of Compliance Identification (XP/DIP) or (IS); (NI) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; CL I, ZN 0/ AEx ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Explosion protection to CSA Certificate of Compliance Identification (XP/DIP) or (IS) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP FG; CL III Siemens FI0 0 US Edition /09
4 Siemens AG 0 HART communication HART communication Ω Protocol HART Version 5.x PROFIBUS PA communication Simultaneous communication with 4 master class (max.) The address can be set using Configuration tool or local operation (standard setting address 6) Cyclic data usage Output byte 5 (one measured value) or 0 (two measured values) Input byte 0,, or (register operating mode and reset function for metering) Internal preprocessing Device profile PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Function blocks Analog input - Adaptation to customer-specific process variables - Electrical damping T 63, adjustable Yes, linearly rising or falling characteristic s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function FOUNDATION Fieldbus communication Function blocks Analog input - Adaptation to customerspecific process variables - Electrical damping T 63, adjustable 3 function blocks analog input, function block PID Yes, linearly rising or falling characteristic s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FF function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function /0 Siemens FI0 0 US Edition
5 Siemens AG 0 HART pressure transmitters, MWP 464/30 psi (PN 3/60) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) Grease-free 3 Measuring span MWP 464 psi (PN 3) inh O ) (... 0 mbar) ) B MWP 30 psi (PN 60) inh O ( mbar) C inh O ( mbar) D inh O ( mbar) E inh O ( mbar) F inh O ( mbar) G psi ( bar) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum 3) Tantalum E Monel 3) Monel H Gold 3) Gold L Version for diaphragm seal 4)5) Y Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to EN Mounting thread M0 to DIN 93 0 Vent on side of process flange ) - Mounting thread 7 / 6-0 UNF to EN Mounting thread M0 to DIN 93 4 Non-wetted parts materials process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision 3 casting 6) Version Standard versions International version, English label inscriptions, documentation in 5 languages on CD Hazardous area rating General purpose A ATEX Hazardous approval - "Intrinsically safe (EEx ia)" B - "Explosion-proof (EExd)" 7) D - "Intrinsically safe and explosion-proof P (EEx ia + EEx d)" 8) - use in zone E - "Intrinsically safe, explosion-proof enclosure R and dust explosion protection (EEx ia + EEx d + zone D/D)" 8) FM/CSA Hazardous approval - "Intrinsically Safe und explosion proof (is + xp)" 7) N C HART pressure transmitters 7 M F , MWP 464/30 psi (PN 3/60) Electrical connection / cable entry Screwed gland Pg 3.5 9) A Screwed gland M0 x.5 B ½-4 NPT C Han 7D plug (plastic housing) incl. mating D connector 9)0) M connectors (metal) ) F Indicator Without indicator 0 Without indicator (digital display hidden, setting: ma) With indicator (digital display visible, setting: ma) 6 With indicator (digital display visible, settings as 7 specified, Order Code "Y"/Y" required) Power supply units see Chap. 8 "Supplementary Components". Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) ) For oxygen cleaning application, add Order code E0. ) Not suitable for connection of remote seal. Position of the top vent valve in the process flanges (see dimensional drawing). 3) Not in conjunction with max. span 0 and 60 mbar (8.03 und 4.09 inh O)) 4) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC , it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) Not in conjunction with Electrical connection "Screwed gland Pg 3.5" and "Han7D plug". 7) Without cable gland, with blanking plug 8) With enclosed cable gland EEx ia and blanking plug 9) Not in conjunction with types of protection "Explosion-proof" and "Ex na", "Intrinsic safety" and "Explosion-proof". 0) Permissible only for crimp-contact of conductor cross-section mm ) M delivered without cable socket Siemens FI0 0 US Edition /
6 Siemens AG 0 Pressure transmitters for differential pressure and flow MWP 464/30 psi (PN 3/60) PA (PROFIBUS PA) 7 M F FF (FOUNDATION Fieldbus) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) Grease-free 3 Nominal measuring range MWP 464 psi (PN 3) 8.03 inh O ) (0 mbar) ) B MWP 30 psi (PN 60) 4.09 inh O (60 mbar) C 00.4 inh O (50 mbar) D 40.9 inh O (600 mbar E 64.4 inh O (600 mbar) F 008 inh O (5 bar) G 435 psi (30 bar) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum 3) Tantalum E Monel 3) Monel H Gold 3) Gold L Version as diaphragm seal 4)5) Y Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to EN Mounting thread M0 to DIN 93 0 Venting on side of process flanges ) - Mounting thread 7 / 6-0 UNF to EN Mounting thread M0 to DIN 93 4 Non-wetted parts materials process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision 3 casting Version Standard versions International version, English label inscriptions, documentation in 5 languages on CD Hazardous area rating General purpose A ATEX Hazardous approval - "Intrinsically safe (EEx ia)" B - "Explosion-proof (EExd)" 6) D - "Intrinsically safe and explosion-proof P (EEx ia + EEx d)" 7) - use in zone E - "Intrinsically safe, explosion-proof enclosure R and dust explosion protection (EEx ia + EEx d + zone D/D)" 7) FM/CSA Hazardous approval - "Intrinsically Safe und explosion proof (is + xp)" 6) N C Pressure transmitters for differential pressure and flow MWP 464/30 psi (PN 3/60) PA (PROFIBUS PA) 7 M F FF (FOUNDATION Fieldbus) 7 M F Electrical connection / cable entry Screwed gland M0 x.5 B ½-4 NPT C M connectors (metal) 8) F Indicator Without indicator 0 Without indicator (digital display hidden, setting: ma) With indicator (digital display visible, setting: ma) 6 With indicator (digital display visible, settings as 7 specified, Order Code "Y"/Y" required) Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) ) For oxygen cleaning application, add Order code E0. ) Not suitable for connection of remote seal. Position of the top vent valve in the process flanges (see dimensional drawing). 3) Not in conjunction with max. span 0 and 60 mbar (8.03 und 4.09 inh O)) 4) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC , it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 5) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 6) Without cable gland, with blanking plug 7) With enclosed cable gland EEx ia and blanking plug 8) M delivered without cable socket / Siemens FI0 0 US Edition
7 Siemens AG 0 Further designs Add "-Z" to and specify Order Code. Order code HART PA FF Pressure transmitter with mounting bracket ( shackles, 4 nuts, 4 U-plates, angle) made of: Steel A0 Stainless steel A0 O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A3 Angled A3 Sealing screws ( unit(s) A40 ¼-8 NPT, with valve in mat. of process flanges Cable sockets for M connectors (metal) A50 Rating plate inscription (instead of German) English B French B Spanish B3 Italian B4 English rating plate B Pressure units in inh O and/or psi Factory calibration certificate ) C Material traceability certificate ) C Factory certificate of conformance C4 SIL certificate per IEC 6508 / 65 C0 PROFIsafe certificate and protocol C Setting of upper limit of D05 output signal to.0 ma Manufacturer's declaration acc. to NACE D07 (only together with seal diaphragm made of Hastelloy and stainless steel) Degree of protection IP68 D (only for M0 x.5 and ½-4 NPT) Process flange screws made of Monel D34 (max. nominal pressure PN0) Supplied with oval flange set D37 ( items), PTFE packings and screws in thread of process flanges Brad Harrison Connector D40 Use in or on zone D/D E0 (only together with type of protection "Intrinsic safety (EEx ia)") TÜV approval to AD/TRD E06 (only together with type of protection "Intrinsic safety (EEx ia)") Further designs Add "-Z" to and specify Order Code. Order code HART PA FF Overfilling safety device for flammable E08 and non-flammable liquids (max. PN 3 (MVWP 464 psi), basic device with type of protection "Intrinsic safety (EEx ia)", to WHG and VbF, not together with measuring cell filling "inert liquid") Oxygen application E0 (In the case of oxygen measurement and inert liquid max. 0 bar a (740 psi a) at 60 C (40 F)) Two coats of lacquer on casing and cover G0 (PU on epoxy) Interchanging of process connection side H0 Vent on side for gas measurements H0 Stainless steel process flanges for vertical H03 differential pressure lines (not together with K0, K0 and K04) 3) Process flange Hastelloy K0 Monel K0 Stainless steel with PVDF insert max. PN 0 (MWP 45 psi), max. temperature of medium 90 C (94 F) K04 Surge Protection External, ½" NPT J0 Manifold Mounting Assembled for 3-valve manifold U0 7MF94-5BA-Z+K36, Chromized steel screws, PTFE-gaskets, and pressure test Assembled for 3-valve manifold U0 7MF94-5BA-Z+K46, Stainless steel screws, PTFE-gaskets, and pressure test Assembled for 5-valve manifold U03 7MF94-5CA-Z+K36, Chromized steel screws, PTFE-gaskets, and pressure test Assembled for 5-valve manifold U04 7MF94-5CA-Z+K46, Stainless steel screws, PTFE-gaskets, and pressure test Factory mounting of valve manifolds, see accessories. Supplementary electronics for 4-wire connection, see accessories. For ½-4 NPT inner process connection on the side in the middle of the process flanges, vent valve not possible = available ) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC , it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. ) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Not suitable for connection of remote seal Siemens FI0 0 US Edition /3
8 Siemens AG 0 Additional data Please add "-Z" to and specify Order code(s) and plain text. Order code HART PA FF Calibrated range Specify in plain text: in the case of linear characteristic curve Y0 (max. 5 characters): Y0: X to Y psi, inh 0, fth 0... in the case of square rooted characteristic Y0 (max. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Tag number/identification Y5 (max. 6 characters), specify in plain text: Y5:... Tag description Y6 (max. 7 characters), specify in plain text: Y6:... Entry of HART (TAG) Y7 (max. 8 characters), specify in plain text: Y7:... Pressure units for digital display Y specify in plain text: Y: psi, inh 0, fth 0... Pressure units for digital display Non-Pressure units for digital display ) (measuring range in pressure units ("Y0"/"Y0") mandatory) specify in plain text: Y: X to y GPM, MGD, Feet... Y ) + Y0 or Y0 Preset bus address Y5 possible between and 6 Specify in plain text: Y5:... Factory mounting of valve manifolds, see accessories. Only "Y0", "Y", "Y", "Y5" and "D05" can be factory preset = available ) Preset values can only be changed over SIMATIC PDM. ) Not in conjunction with over-filling safety device for flammable and nonflammable liquids (Order Code "E08") /4 Siemens FI0 0 US Edition
9 Siemens AG 0 HART pressure transmitters, MWP 609 psi (PN 40) 7 M F Measuring cell filling Measuring cell cleaning Silicone oil normal Measuring span inh O ( mbar) D inh O ( mbar) E inh O ( mbar) F inh O ( mbar) G psi ( bar) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Gold ) Gold L Connection of remote seal possible on request Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to EN Mounting thread M to DIN 93 Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing) - Mounting thread 7 / 6-0 UNF to EN Mounting thread M to DIN 93 5 Non-wetted parts materials process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision 3 casting ) Version Standard versions International version, English label inscriptions, documentation in 5 languages on CD Hazardous area rating General purpose A ATEX Hazardous approval - "Intrinsically safe (EEx ia)" B - "Explosion-proof (EExd)" 3) D - "Intrinsically safe and explosion-proof P (EEx ia + EEx d)" 4) - use in zone E - "Intrinsically safe, explosion-proof enclosure R and dust explosion protection (EEx ia + EEx d + zone D/D)" 4) FM/CSA Hazardous approval - "Intrinsically Safe und explosion proof (is + xp)" 3) N C Electrical connection / cable entry Screwed gland Pg 3.5 5) A Screwed gland M0x.5 B ½-4 NPT C Han 7D plug (plastic housing) incl. mating D connector 5)6) M connectors (metal) 7) F HART pressure transmitters 7 M F , MWP 609 psi (PN 40) Indicator Without indicator 0 Without indicator (digital display hidden, setting: ma) With indicator (digital display visible, setting: ma) 6 With indicator (digital display visible, settings as 7 specified, Order Code "Y"/Y" required) Power supply units see Chap. 8 "Supplementary Components". Scope of delivery: Pressure transmitter as ordered (Instruction Manual is extra ordering item) ) Not in conjunction with max. span 600 mbar (40.9 inh O) ) Not in conjunction with Electrical connection "Screwed gland Pg 3.5" and "Han7D plug". 3) Without cable gland, with blanking plug 4) With enclosed cable gland EEx ia and blanking plug 5) Not in conjunction with types of protection "Explosion-proof" and "Ex na", "Intrinsic safety" and "Explosion-proof". 6) Permissible only for crimp-contact of conductor cross-section mm 7) M delivered without cable socket Siemens FI0 0 US Edition /5
10 Siemens AG 0 Pressure transmitters for differential pressure and flow, MWP 609 psi (PN 40) PA (PROFIBUS PA) 7 M F FF (FOUNDATION Fieldbus) 7 M F Nominal measuring range 00.4 inh O (50 mbar) D 40.9 inh O (600 mbar) E 64.4 inh O (600 mbar) F 008 inh O (5 bar) G 435 psi (30 bar) H Wetted parts materials (stainless steel process flanges) Seal diaphragm Parts of measuring cell Stainless steel Stainless steel A Hastelloy Stainless steel B Gold ) Gold L Connection of remote seal possible on request Process connection Female thread ¼-8 NPT with flange connection Sealing screw opposite process connection - Mounting thread 7 / 6-0 UNF to EN Mounting thread M to DIN 93 Venting on side of process flanges, location of vent valve at top of process flanges (see dimensional drawing). - Mounting thread 7 / 6-0 UNF to EN Mounting thread M to DIN 93 5 Non-wetted parts materials Process flange screws Electronics housing Stainless steel Die-cast aluminum Stainless steel Stainless steel precision 3 casting Version Standard versions International version, English label inscriptions, documentation in 5 languages on CD Hazardous area rating General purpose A ATEX Hazardous approval - "Intrinsically safe (EEx ia)" B - "Explosion-proof (EExd)" ) D - "Intrinsically safe and explosion-proof P (EEx ia + EEx d)" 3) - use in zone E - "Intrinsically safe, explosion-proof enclosure R and dust explosion protection (EEx ia + EEx d + zone D/D)" 3) FM/CSA Hazardous approval - "Intrinsically Safe und explosion proof (is + xp)" ) N C Electrical connection / cable entry Screwed gland M0 x.5 B ½-4 NPT C M connectors (metal) 4) F Pressure transmitters for differential pressure and flow, MWP 609 psi (PN 40) PA (PROFIBUS PA) 7 M F FF (FOUNDATION Fieldbus) 7 M F Indicator Without indicator 0 Without indicator (digital display hidden, setting: ma) With indicator (digital display visible, setting: ma) 6 With indicator (digital display visible, settings as 7 specified, Order Code "Y" required) Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation Sealing plug(s) or sealing screw(s) for the process flanges(s) ) Not in conjunction with max. span 600 mbar (40.9 inh O) ) Without cable gland, with blanking plug 3) With enclosed cable gland EEx ia and blanking plug 4) M delivered without cable socket /6 Siemens FI0 0 US Edition
11 Siemens AG 0 Further designs Add "-Z" to and specify Order Code. Order code HART PA FF Pressure transmitter with mounting bracket ( shackles, 4 nuts, 4 U-plates, angle) made of: Steel A0 Stainless steel A0 O-rings for process flanges (instead of FPM (Viton)) PTFE (Teflon) A0 FEP (with silicone core, approved for food) A FFPM (Kalrez, compound 4079) A NBR (Buna N) A3 plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A3 Angled A3 Sealing screws ( unit(s) A40 ¼-8 NPT, with valve in mat. of process flanges Cable sockets for M connectors (metal) A50 Rating plate inscription (instead of German) English B French B Spanish B3 Italian B4 English rating plate B Pressure units in inh O and/or psi Factory calibration certificate C Material traceability certificate C Factory certificate of conformance C4 SIL certificate per IEC 6508 / 65 C0 PROFIsafe certificate and protocol C Setting of upper limit of D05 output signal to.0 ma Manufacturer's declaration acc. to NACE D07 (only together with seal diaphragm made of Hastelloy and stainless steel) Degree of protection IP68 D (only for M0 x.5 and ½-4 NPT) Brad Harrison Connector D40 Use in or on zone D/D E0 (only together with type of protection "Intrinsic safety (EEx ia)") Further designs Add "-Z" to and specify Order Code. Order code HART PA FF Two coats of lacquer on casing and cover G0 (PU on epoxy) Interchanging of process connection side H0 Stainless steel process flanges for vertical H03 differential pressure lines Surge Protection External, ½" NPT J0 Manifold Mounting Assembled for 3-valve manifold U0 7MF94-5BA-Z+K36, Chromized steel screws, PTFE-gaskets, and pressure test Assembled for 3-valve manifold U0 7MF94-5BA-Z+K46, Stainless steel screws, PTFE-gaskets, and pressure test Assembled for 5-valve manifold U03 7MF94-5CA-Z+K36, Chromized steel screws, PTFE-gaskets, and pressure test Assembled for 5-valve manifold U04 7MF94-5CA-Z+K46, Stainless steel screws, PTFE-gaskets, and pressure test Additional data Please add "-Z" to and specify Order code(s) and plain text. Calibrated range Specify in plain text: in the case of linear characteristic curve Y0 (max. 5 characters): Y0: X to Y psi, inh 0, fth 0... in the case of square rooted characteristic Y0 (max. 5 characters): Y0:... up to... mbar, bar, kpa, MPa, psi Tag number/identification Y5 (max. 6 characters), specify in plain text: Y5:... Tag description Y6 (max. 7 characters), specify in plain text: Y6:... Entry of HART (TAG) Y7 (max. 8 characters), specify in plain text: Y7:... Pressure units for digital display Y specify in plain text: Y: psi, inh 0, fth 0... Pressure units for digital display Non-Pressure units for digital display ) (measuring range in pressure units ("Y0"/"Y0") mandatory) Specify in plain text: Y:.X to Y GPM, MGD, Feet... Y + Y0 or Y0 Preset bus address Y5 possible between and 6 Specify in plain text: Y5:... Factory mounting of valve manifolds, see accessories. Only "Y0", "Y", "Y", "Y5" and "D05" can be factory preset. = available ) Preset values can only be changed over SIMATIC PDM. Siemens FI0 0 US Edition /7
12 Dimensional drawings Siemens AG 0 5 (0.6) 44 (5.67) 5 (.0) 0 (0.8) approx. 30 (.) 5) 00 (3.94) 6 Ø80 (3.5) 50 (.97) 34 (5.7) 5 ) - 74 (.9) 90 (3.6) 4) + 4 ) Space for rotation of housing 7 (4.6) 3 0 approx. 96 (3.78) 5 (.05) 98 (7.8) (3.8) approx. 6 (0.3) ø ( ) 3 7 (.83) 05 (4.) Process connection: ¼-8 NPT (EN 658) Blanking plug 3 Electrical connection: - Screwed gland Pg 3,5 (adapter) ) 3), only DS III HART, - Screwed gland M0x,5 3), - Screwed gland ½-4 NPT, - Han 7D/Han 8D ) 3) plug, only DS III HART, or - M connector 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 0 Lateral venting for liquid measurement (Standard) Lateral venting for gas measurement (suffix H0) 68 (.7) 0 (4.7) ) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator 5) 45 mm (.8 inch) for Pg 3,5 with adapter pressure transmitters, dimensions in mm (inch) /8 Siemens FI0 0 US Edition
13 Siemens AG 0 5 (0.6) 74 (.9) 44 (5.67) 5 (.0) approx. 30 (.8) 8) approx. 96 (3.78) 00 (3.94) 6 Ø 80 (3.5) 5 ) 90 (3.6) 4) 0 (0.8) 4 ) 50 (.97) Space for rotation of housing 3 3 approx. 85 (3.35) 6) approx. 7 (8.54) 7) 67 (.64) 5) approx. 84,6 (3.33) Process connection: ¼-8 NPT (EN 658) Blanking plug 3 Electrical connection: - Screwed gland Pg 3,5 (adapter) ) 3), only DS III HART, - Screwed gland M0x,5 3), - Screwed gland ½-4 NPT, - Han 7D/Han 8D ) 3) plug, only DS III HART, or - M connector 4 Terminal side 5 Electronics side, digital display (longer overall length for cover with window) 6 Protective cover over keys 7 Mounting bracket (option) 8 Sealing screw with valve (option) 9 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) ) Allow approx. 0 mm (0.79 inch) thread length to permit unscrewing ) Not with type of protection "explosion-proof enclosure" 3) Not with type of protection "FM + CSA [is + xp]" 4) 9 mm (3.6 inch) for minimum distance to permit rotation with indicator 5) 74 mm (.9 inch) for PN 40 (MWP 609 psi) 6) 9 mm (3.6 inch) for PN 40 (MWP 609 psi) 7) 9 mm (8.6 inch) for PN 40 (MWP 609 psi) 8) 45 mm (.8 inch) for Pg 3,5 with adapter pressure transmitters, with process covers for vertical differential pressure lines, optional "H03", dimensional drawing, dimensions in mm (inch) pressure transmitters, with process covers for vertical differential pressure lines Siemens FI0 0 US Edition /9
8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.
SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output
More informationPlastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases
Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma
More informationRosemount 1152 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment
More informationFuji Electric France S.A. DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS FKC...5 DATA SHEET. Functional specifications.
DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER DATA SHEET The FCX AII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits
More informationFlow Measurement SITRANS F M
Overview The MAG is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. Benefits Wide range of sizes: DN 15 to DN 2000 (½ to 78 ) The flexible design
More informationAT9000 Advanced Transmitter Absolute Pressure Transmitters
No. SS2-GTX00A-0500 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent
More informationPressure transducers DMU 02 Vario (flush)
Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load
More informationRosemount 1154 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10
More informationTSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max
Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless
More informationFlow measurement of Liquids and Gases
Flow measurement of Liquids and Gases Metallic construction Operates horizontally or vertically DN 40 to DN 500 Flow rate: - Water: 0.8 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 24000 Nm 3 /h.
More informationRHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits
RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty
More informationAT9000 Advanced Transmitter Absolute Pressure Transmitters
No. SS2-GTX00A-0100 (Rev.8) AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and
More informationTSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max
Flap Flow Meter for Liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless
More informationDigital E3 Modulevel Liquid Level Displacer Transmitter
Digital E3 Modulevel Liquid Level Displacer Transmitter D E S C R I P T I O N The Digital E3 Modulevel is an advanced, intrinsically safe two-wire instrument utilizing simple buoyancy principle to detect
More informationSITRANS T measuring instruments for temperature
Technical description Siemens AG 2008 Design Function A resistance thermometer comprises Measuring resistor the measuring resistor (metal; platinum, Pt or nickel, Ni) and Measuring resistors the mounting
More informationDiaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel
Ed.17.01 Design Diaphragm Seal with flush diaphragm and flange acc.to EN 1092-1 or ASME B 16,5 Pressure gauge in stainless steel Type Lower body Flush diaphragm with flange connection acc.to EN 1092-1
More informationSITRANS L Level instruments
Overview Configuration is a guided wave radar transmitter for short and medium range level, level/interface and volume measurement of liquids and solids. It is unaffected by changes in process conditions,
More informationCoriolis Mass Flowmeter serving thousands of worldwide applications
RHM 08 - A standard Coriolis Mass Flowmeter serving thousands of worldwide applications The RHM 08 can measure flow rates up to 50 kg/min (110 lb/min) with temperatures in excess of 400 C and pressures
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationTechnical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:
Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations Note: These are general specifications and guidelines for Mass Flow Meters for Petroleum Oil Installations.
More information4-Beam-Turbidity Meter ITM-4
SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-4 FOOD 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 May 2009 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationRosemount Compact Orifice Flowmeter Series
INTEGRATED DESIGN FOR LIMITED STRAIGHT PIPE RUN, CLOSED LOOP CONTROL, AND GENERAL PURPOSE MONITORING APPLICATIONS Reduced installation cost compared to a traditional orifice plate Accurate and repeatable
More informationELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200
ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.
More informationShur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual
Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual P/N 1000006053 Rev E $7%$QDO\WLFV// //& 733 Dairy Rd. Parkton, Md. 21120 www.atbanalytics.com (410) 733-6365 Table of Contents Chapter 1: Getting
More informationKDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...
All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : 0.1-1 l/h... 20-200 l/h water 5 - Nl/h... 600-6000 Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection:
More informationLevel measurement Ultrasonic. Overview VEGASON series VEGASON series Dimensions Level measurement Ultrasonic
Level measurement Ultrasonic Contents Page Overview... 40 VEGASON series 60... 42 VEGASON series 70... 48 Dimensions... 50 AL - EN - 39 VEGASON: Non-contact measurement of liquids and solids with ultrasonic
More informationTHE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES
THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:
More informationLiquid level switch BW 17
KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level
More informationMagnetic float switch For vertical installation Model FLS for nuclear power plants
Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost
More informationDiaphragm seal with flange connection With internal diaphragm, threaded design Model
Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationPRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.
PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts
More informationCLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories
CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid
More informationSentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications
GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available
More informationDS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice
00813-0100-4686 DS-4018 English Rev. FA ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice DP FLOW - THE INDUSTRY
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationSECTION PRESSURE AND DIFFERENTIAL PRESSURE GAUGES
SECTION 40 72 43 PRESSURE AND DIFFERENTIAL PRESSURE GAUGES PART 1- GENERAL A. The Waterpilot FMX21 is designed for hydrostatic level measurement. It has a robust ceramic sensor and integrated temperature
More informationModel 140MX Flowmeter Functional Overview
A higher level of performance Model 14MX Flowmeter Functional Overview DESCRIPTION The Model 14MX Flowmeter (Figure 1) works on the fluid phenomenon of momentum exchange (see page 6 for details), providing
More informationData Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.
Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ
More informationElectromagnetic flowmeter ProcessMaster FEP300/500 The first choice for the process industry
Electromagnetic flowmeter ProcessMaster FEP300/500 The first choice for the process industry ProcessMaster For all applications ProcessMaster is the perfect fl owmeter for various industries: chemical,
More informationTarget Inline Flowmeter
Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted
More informationTechnical Information Ceragel CPS71 and CPS71D
TI00245C/07/EN/13.12 71193801 Products Solutions Services Technical Information Ceragel CPS71 and CPS71D ph single-rod electrode system, analog and digital with Memosens technology For process technology
More informationSensor unit MC2 for toxic gases and oxygen with analog output
Page 1 July 2016-2 Exchangeable sensor unit including digital value processing, temperature compensation and self control for the continuous monitoring of the ambient air. The sensor unit MC2 houses a
More informationPressure & Differential Pressure Transmitter
Pressure & ifferential 3051 eries GRAL The ALP-3051 is an intelligent differential pressure transmitter that combines proven capacitave sensor measuring techniques (piezoresistive sensors for absolute
More informationOver pressure Switching pressure difference (typical) Lower range Upper range
Allfluid pressure switches electromechanical actuated -... 63 bar, G/2 For Ex zones and 2 (gases) as well as Ex zones 2 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold
More informationPressure - Process pressure
Pressure Process ressure Pressure - Process ressure Overview 126 VEGABAR 14, 17 128 VEGABAR 42 132 VEGABAR 52, 53, 54 134 Accessory 140 Dimensions 142 AL-EN - 125 Pressure Process ressure VEGABAR 10/40/50:
More informationModel 1159 Remote Diaphragm Seals
00813-0100-0 English May 1999 Rev. AB 119 Remote Diaphragm Seals with 112, 113 Series B, D and F, and 11 Alphaline Nuclear Pressure Transmitters Product Discontinued 119 Remote Diaphragm Seals Qualified
More informationMeasuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600
Bypass Level Indicators ATEX or GL Approval measuring monitoring analysing NBK -ATEX,-GL -03, -06, -07, -10 Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart Pressure: max.
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationMERIGAUGE MODEL 3900 OPERATING INSTRUCTIONS
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com MERIGAUGE MODEL 3900 OPERATING INSTRUCTIONS Meriam Instrument s MERIGAUGE Model
More informationVersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.
VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet 34-VF-03-12 October 2009 Specification The solution for bulk mass flow measurement The VersaFlow Coriolis 200 has been developed to meet
More informationWeighing Electronics. SIWAREX - PLC-based weighing modules SIWAREX FTC. Overview
Weighing Electronics Siemens AG 01 Overview Application The weighing module is the optimum solution wherever high demands are placed on continuous weighing procedures. Thanks to its outstanding measuring
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet. Specification. The superior solution. Highlights. Applications.
VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet 34-VF-03-03 29 th May, 2009 Specification The superior solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight
More informationOPTIMASS 7400 Technical Datasheet
OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used
More informationTHERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials
THERMOMETERS Thermometers are used to measure temperature. PIC stocks a variety of temperature measuring instruments, including bimetals, magnetic thermometers, tridicators and scale thermometers. STANDARD
More informationS700 Modular Gas Analyzer. Measures more than 60 different gases
Product information S7 Modular Gas Analyzer Measures more than 6 different gases Modular +++ Superior Quality +++ Universal C US Typical Applications Chemical and petrochemical process gas analysis Ammonia
More informationDiaphragm seal with flange connection With internal diaphragm Model
Diaphragm seals Diaphragm seal with flange connection With internal diaphragm Model 990.26 WIKA data sheet DS 99.26 for further approvals see page 7 Applications Aggressive, highly viscous, crystallising
More informationBM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS
GUIDED WAVE RADAR LEVEL INSTRUMENTS DESCRIPTION The microwaves impulses at high frequency travel through a stainless steel guide and they are reflected on the surface of the fluid to analyze. The period
More informationGlass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures
BPG 42 The BPG range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,
More informationSECTION Coriolis Mass Flow Meters
SECTION 40 71 73 Coriolis Mass Flow Meters PART 1- GENERAL 1.01 SUMMARY A. Coriolis flow meter for permanent installation above ground. The meter shall utilize a measuring principle based on the controlled
More informationO to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications
Diaphragm Seals > Diaphragm Seals Diaphragm Seals Diaphragm seals, also referred to as chemical seals, are used to isolate pressure gauges, switches and transmitters from clogging and/or corrosive media.
More informationTUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS
TUFFY T3 Side Mounting Level Controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact
More informationAnalytical Instruments
Smart Sensors Unique measurement technology Unique Innovations Honeywell is an industry proven leader for analytical products and solutions with unique technologies. Innovations in analytical measurements
More informationDiaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume
Pressure Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.41, large working volume WIKA data sheet DS 99.32 for further approvals see page 7 Applications Aggressive,
More informationDATA SHEET MS2500_EN-IT_DS006REV14
DATA SHEET MS 2500 INDEX TECHNICAL DATA 2 97/23/CE PED DIRECTIVE 3 OVERALL DIMENSIONS 4 SENSOR VERSIONS/JUNTION BOX 7 SEPARATE VERSION 8 INSTALLATION RECOMMENDATIONS 9 RECOMMENDED INSTALLATION PROCEDURE
More informationPressure Booster System. Hya-Eco VP. Type Series Booklet
Pressure Booster System Hya-Eco VP Type Series Booklet Legal information/copyright Type Series Booklet Hya-Eco VP KSB Aktiengesellschaft Frankenthal All rights reserved. Contents provided herein must neither
More informationARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:
GENERAL DESCRIPTION Crude oil well test manifold to be provide as Multiport Flow Selector (MPFS) technology. It provides a cost effective method for selecting and diverting well fluids from an individual
More informationFLUIDISTOR GAS FLOWMETER GD 100 (EX)
FLUIDISTOR GAS FLOWMETER GD 100 (EX) for measuring of all technical and medical gases DN25 - DN400 Oscillating measuring principle, without moving parts Resistent to dirt, e.g. oil and rust residues in
More informationBMA-System#3 Technical Application Sheet
BMA-System#3 Technical Application Sheet DESALTER INTERFACE CONTROL It is all too easy to forget that the primary function of the desalting system is the removal of inorganic chlorides and other water-soluble
More informationLevel Sensors 1001 Table of contents
Table of contents Index Table of contents 4 Description and function 5 Certificates / Approvals 6-7 Level Sensors 1001 Stainless steel DN10 to DN500 8 Brass DN10 to DN80 9 Titanium DN10 to DN500 10 Alloy
More informationVisual Level Indicators VLI
WEKA Visual Level Indicators VLI Certified according ISO 9001:2000 Certified according PED 97/23/EC Member of the Group Certified according ATEX 94/9/EC Principles of design Single-pole Magnet System The
More informationMechatronic pressure measurement. Applications. Special features. Description
Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE
SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE C20 C21 C26-2 C26-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration
More informationOmnigrad M TR47, TR48
Technical Information Omnigrad M TR47, TR48 Hygienic, modular RTD assembly for weld-in installation Various process connections and fast response time Application All hygienic applications for food, pharmaceutical
More informationTechnical Information Orbisint CPS11D and CPS11
TI00028C/07/EN/14.15 71299911 Products Solutions Services Technical Information Orbisint CPS11D and CPS11 ph electrodes, analog or with digital Memosens technology For standard applications in process
More informationEuroFID Total Hydrocarbon Analyzer
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Analyzers and Process Instrumentation Proven Analyzer
More informationFlow Rate Transmitters/ Flow Switches
Flow Rate ransmitters/ Flow Switches FOw RAE RANSMIERS FOw SwICHES o measure the flow rate in machines and systems HYDAC EECRONIC offers various fl ow rate transmitters and fl ow switches. he fl ow rate
More informationMS50 Buoyancy level switch. K-TEK products. Measurement made easy. Features. Typical applications
Data Sheet DS/MS50-EN Rev. X MS50 Buoyancy level switch K-TEK products Measurement made easy Single Float Multi-Float Features Up To Six SPDT Switches Per Unit (NO & NC Contacts) Interface & Total Level
More informationCAPACITIVE LEVEL SENSORS DLS 27
CAPACITIVE LEVEL SENSORS DLS 27 For limit level sensing of liquid, and bulk-solid and powder materials Xi version for usage in explosive areas Direct mounting into various containers, silos, vessels, tanks,
More informationSeries Sump and Sewage Systems
Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column
More informationVERIS Accelabar. Superior Flow Measurement Accuracy
VERIS Superior Flow Measurement Accuracy Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. ...A New Idea in Flow
More informationProsonic Flow B 200. For reliable flow measurement of biogas without limitations
Prosonic Flow B 200 For reliable flow measurement of biogas without limitations Specially designed ultrasonic flowmeter for measuring biogas, landfill or digester gas One-of-a-kind direct measurement of
More informationLevel Switch. Series. instrumentation for fluids LC40. Instructions Manual
instrumentation for fluids Level Switch Series LC40 Instructions Manual R-MI-LC40 Rev.:3 English Version TABLE OF CONTENTS 1. INTRODUCTION... 3 2. RECEPTION... 3 3. INSTALLATION... 3 4. ELECTRICAL CONNECTION...
More informationO O Pressure: max. PN 100 / Class 600. O O Temperature: -40 C C (ceramic rollers) 0 C C (PP-rollers)
ypass Level Indicators ATEX or GL Approval measuring monitoring analysing NK -ATEX,-GL -03, -06, -07, -10 O O Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart O O Pressure:
More informationSITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids
SITRANS F X Vortex flowmeter The optimum measurement device for steam, gases and liquids SITRANS F Answers for industry. Totally integrated solutions from a single supplier Industry segments: Chemical
More informationRed Eye Multiphase Water-Cut Meter
Red Eye Multiphase Water-Cut Meter Water-cut measurements in multiphase flow. Weatherford has redefined the water-cut meter market by addressing many of the difficulties in accurately measuring water cut
More informationTTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma
Thermocouple Thermometers Ignition Protection Exd measuring monitoring analysing TTL-Exd T2 O O Measuring ranges: max. 1100 C OO NiCr-Ni or Fe-CuNi thermocouples OO Output: sensor or analogue 4-20 ma O
More informationContinuous Level Sensor CONDURIX 31.1
Continuous Level Sensor CONDURIX CONDURIX The Continuous Measurement of Filling Levels according to the Potentiometric Measuring Principle The CONDURIX Sensor supplies information on filling levels of
More information94130 Pressure Relief Vent (Open or Closed Vent Option) Features
94130 (Open or Closed Vent Option) The Shand & Jurs 94130 is designed to provide pressure relief with high efficiency, maximum flow capacity and minimum leakage. The easily serviceable configuration and
More informationA World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...
A World of Gases A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter... ATI Presents A Simpler Approach To Toxic Gas Detection. One Transmitter Is All You Need. Time was, monitoring multiple
More informationVersaFlow Coriolis 6000 Sensor for Mass Flow Specifications
VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications 34-VF-03-27, July 2017 The Solution for extended temperature applications A high level of performance, together with a wide operating temperature
More information