Technical Specification for Galvanised Fabricated Steelwork

Similar documents
Technical Specification for Steel Forged Fittings

Technical Specification for Aluminium Castings, Pole Caps and Pressed Symbols

Technical Specification for Live Line Tap Connectors

Technical Specification for Helical Fittings for Overhead Power Lines

Technical Specification for LV ABC Fuse Switch Disconnectors

660 Volts 630 & 800AMP

Technical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables

Technical Specification for Outdoor Porcelain Station Post Insulators

Technical Specification for Insulated Low Voltage Single Core Copper Cable

Galvanised Fabricated Metalwork

Technical Specification for 12kV, 24kV and 36kV Disconnector (Isolators)

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

Specification for Fabrication of Steelwork for Pole Structures

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

Conduits. Technical Specification for Conduits and Associated Materials. JTS Version 1

Specification for the Fabrication of Tower Structures

SPECIFICATION SS-20 / 4 STEEL STRUCTURES FOR SUBSTATION AND SWITCHING STATION MATERIAL

SPECIFICATION FOR STOCKBRIDGE TYPE VIBRATION DAMPERS FOR DISTRIBUTION AND TRANSMISSION OVERHEAD LINES

TABLE OF CONTENTS INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

NPS/002/001 Technical Specification for Earthing Materials

093 : 2000 CEB STANDARD MEDIUM VOLTAGE PIN POST INSULATORS AND HARDWARE CEYLON ELECTRICITY BOARD SRI LANKA

Technical Specification for Low Voltage Regulator

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

NPS/003/033 Technical Specification for Substation Support Structures

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

HANLON AND PARTNERS LTD Consulting Structural & Fire Engineers. Specification for. Mental Health Acute Inpatient Unit Wakari Hospital, Dunedin

Electrical Services Standard Specification Cable Tray Installation. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

Technical Specification for 12kV, 24kV AND 36kV Unitised Ganged Airbreak Switches

AS/NZS :2016. High-strength steel fastener assemblies for structural engineering Bolts, nuts and washers AS/NZS :2016

CONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - EXTRUDER TERMINAL SYSTEM

Australian/New Zealand Standard

SPECIFICATION FOR 11 & 33kV COMPOSITE INSULATORS Part 1: Pin Type

TECHNICAL SPECIFICATION

ANNEXURE - ' D ' TECHNICAL SPECIFICATION FOR INSULATOR PINS ( PINS FOR 11,22 AND 33 kv INSULATORS )

FIJI ELECTRICITY AUTHORITY BIDDING DOCUMENT

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

CONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - ECCENTRIC LOADER TERMINAL SYSTEM

Australian/New Zealand Standard

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO. Ltd. (MUMBAI) SCHEDULE 'A' TECHNICAL SPECIFICATION FOR. 11 kv, 22 kv & 33 kv HORN GAP FUSES FOR

Product Guide Specification

EXPRESSION OF INTEREST (EOI) FOR. Mechanical Works

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATION FOR G.I. BARBED WIRE. (SPECIFICATION NO.MM/I/G.I.BARBED WIRE/2006) (Dt )

Comparison of BS and BS EN for steel materials

Standard Pole Range 5. In-Ground Mounted 6. Ground Line Protection 6. Base Plate Mounted 6. Quality & Design Standards 7. Quality Standard 7

Contents EN :2008+A1:2011 (E) Page

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

SPECIFICATION FOR DISC INSULATORS (Standard Type)

Draft for comments only Not to be cited as East African Standard

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION 15 STRUCTURAL STEEL

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

Date: TECHNICAL SPECIFICATION FOR (LT,11KV, 33KV) PORCELAIN PIN INSULATORS

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

AS/NZS 5131:2016. Australian/New Zealand Standard. Structural steelwork Fabrication and erection AS/NZS 5131:2016

Specification Technical Requirements for Overhead Conductors up to and including 33 kv

SECTION TIMBER FLOATS

ARCHITECTURAL SPECIFICATIONS

ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME. Technical Specification (T.S)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Special Provision No. 915S03 December References, Materials, Construction, and Quality Assurance for Sign Support Structures

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION METAL FLOOR PLATE STAIRS

SECTION COLD-FORMED METAL TRUSSES

complete with pallet support bars, column guards, safety barriers, pallet back stopper painting

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

ONTARIO PROVINCIAL STANDARD SPECIFICATION

METAL FABRICATION..1 General Conditions and Division 1 shall govern Work of this section.

Nylofor Swing Gate. Figure 1: Single Nylofor Swing Gate

066 : 1998 CEB STANDARD GALVANIZED IRON PIPES FOR SERVICE CONNECTIONS CEYLON ELECTRICITY BOARD SRI LANKA

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

STAINLESS STEEL. Useful Information

AS/NZS :2016. Australian/New Zealand Standard. Structural steel. Part 2: Welded I sections. Superseding AS/NZS :2010 AS/NZS 3679.

Part 7: 1992 Specification for materials and workmanship Cold-formed

CONSTRUCTION SPECIFICATION FOR EXPANDED METAL ANTI-GLARE SCREEN

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

MGVCL/MM/1043/13-14/11 KV Disc Insulators (Porcelain)

Tel : , Fax : P.O Box No , Dubai Investment Park 1 Dubai - United Arab Emirates

CORRIGENDUM No: 1. to the. Volume 3: Technical Specifications. Publication Ref: BAM/ADMP/GPF/WRK/VC

CONSTRUCTION SPECIFICATION

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

SECTION DECORATIVE METAL FENCES AND GATES

TECHNICAL SPECIFICATION FOR CONDUCTOR HARDWARE FITTING FOR 11/22/33 kv OVERHEAD POWER LINES

Hot Dip Galvanized Case Study No. 21 Eskom Coastal Sub-station

SECTION 716 SIGN MATERIALS SCOPE

NPS/001/003 Technical Specification for 11kV, 20kV and 33kV Overhead Line Air Break Switch-Disconnectors

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

Technical Specification for Substation 11kV and 22kV Single Core Underground Cable

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL

SPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS:

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF UNDERPASS LUMINAIRES

11KV PORCELAIN INSULATORS AND FITTINGS

Transcription:

Ergon Energy Corporation Limited Technical Specification for Galvanised Fabricated ETS 01-03-01 Check this is the latest Process Zone version before use. Specification ETS 01-03-01 Ver 1

Contents 1. Purpose and Scope... 4 2. References... 4 2.1 Applicable Standards... 4 3. Drawings... 4 3.1 Drawings by the Purchaser... 4 4. Service Conditions... 4 5. Design and Construction... 5 5.1 Identification Reference... 5 5.2 Corrosion Protection... 5 5.3 Ratings... 5 5.4 Bolts (Screws) Nuts and Washers... 5 5.5 Holes... 5 5.6 Welding... 5 5.7 Assembly... 5 5.8 Dimensions and Tolerances... 5 6. Performance and Testing... 6 6.1 Certificates of Compliance... 6 7. Risk Assessment... 6 8. Quality Assurance... 6 8.1 Purchasers Policy... 6 8.2 Documentary Evidence... 6 8.3 Quality Certification Program... 6 9. Samples... 6 9.1 Production Samples... 6 10. Packaging and Marking... 6 10.1 Safe Handling of Products... 6 10.2 Packages Lots... 7 11. Service Performance... 7 12. Reliability... 7 Check this is the latest Process Zone version before use. i Specification ETS 01-03-01 Ver 1

12.1 Service Life... 7 13. Training... 7 14. Environmental Considerations... 7 15. Information to be Provided... 7 15.1 Specific Technical Requirements... 7 15.2 Checklist of Supporting Documentation... 8 16. Attachment 1 Technical Details... 9 17. Attachment 2 Technical Document Checklist... 10 Check this is the latest Process Zone version before use. i Specification ETS 01-03-01 Ver 1

1. Purpose and Scope This technical specification sets out the requirements for the manufacture, testing at works, supply and delivery of galvanized fabricated steelwork for use on overhead electricity distribution systems in a totally exposed environment. 2. References 2.1 Applicable Standards All items shall be designed, manufactured and tested with the relevant parts of the following Standards and all amendments issued from time to time except where varied by this specification. STANDARD AS 1111 AS 1112 AS 1154 AS 1214 AS 1237 AS 1275 AS 1442 AS/NZS 1554 AS/NZS 1594 AS/NZS 3678 AS/NZS 3679 AS 3766 AS 4068 AS 4680 AS/NZS 9001 TITLE ISO metric hexagon commercial bolts and screws ISO metric hexagon nuts, including thin nuts, slotted nuts and castle nuts Insulator and conductor fittings for overhead power lines Hot-dip galvanized coatings on threaded fasteners Flat metal washers for general engineering purposes Metric screw threads for fasteners Carbon steels and carbon-manganese steels - Hot-rolled bars and semifinished products Structural steel welding Hot-rolled steel flat products Structural steel - Hot-rolled plates, floorplates and slabs Structural steel - Hot rolled bars and sections Mechanical fittings for low voltage aerial bundled cables Flat pallets for materials handling Hot-dipped galvanised (zinc)coatings on fabricated ferrous articles Quality management systems - Requirements 3. Drawings 3.1 Drawings by the Purchaser There are no drawings attached to this specification. 4. Service Conditions The items will be exposed to the following environmental conditions: Check this is the latest Process Zone version before use. Page 4 of 10 Specification ETS 01-03-01 Ver 1

Temperatures 45 o C summer day time -5 o C winter night time Solar Radiation Level 1 000 Wm 2 with high ultraviolet content Precipitation Tropical summer storms with gust winds above 160 km/h, and an annual rainfall in excess of 1 500 mm Humidity Extended periods of relative humidity in excess of 90%. Pollution Areas of coastal salt spray and/or industrial pollution with equivalent salt deposit densities in the range 2.0 to 3.0 gm -2 5. Design and Construction 5.1 Identification Reference Prior to galvanizing, all fittings where applicable, shall be permanently marked with the appropriate identification reference together with the manufacturer's name or trade mark. These shall be applied in such a way as to remain legible after galvanizing. 5.2 Corrosion Protection All ferrous items with the exception of stainless steel, shall be hot dipped galvanized in accordance with AS 4680 and/or AS 1214 as applicable after fabrication. The minimum coating thickness shall be 84 µm. 5.3 Ratings All steelwork shall be manufactured to meet the design requirements stated on the applicable QESI and ERGON drawings. 5.4 Bolts (Screws) Nuts and Washers All bolts and nuts shall be threaded in accordance with AS 1111 and AS 1112 respectively. The resulting thread form shall have tolerance class of 6H/8g. Internal threads shall be cut and oiled after galvanizing. 5.5 Holes All holes shall be drilled accurately to the required tolerances as specified on the applicable drawings. 5.6 Welding Welding shall be in accordance with AS 1554, Parts 1 and 2 or as otherwise indicated on the relevant QESI and ERGON drawing. 5.7 Assembly Where specified, parts shall be assembled before delivery. 5.8 Dimensions and Tolerances All dimensions and tolerances shall be in accordance with the applicable QESI and ERGON drawing or relevant Australian Standard if not stated thereon. Check this is the latest Process Zone version before use. Page 5 of 10 Specification ETS 01-03-01 Ver 1

6. Performance and Testing 6.1 Certificates of Compliance Certificates of Compliance are to be provided with each delivery to verify that the materials used comply with the specified grade requirements detailed on the relevant drawings. 7. Risk Assessment There is no requirement for manufacturer provided safety risk assessments for the items covered in this specification. 8. Quality Assurance 8.1 Purchasers Policy It is the Purchaser s policy to procure goods, equipment and services from sources that demonstrate the ability to supply quality products. The tenderers attention is drawn to the relevant Quality Assurance Annexure that forms an integral part of this specification. 8.2 Documentary Evidence Documentary evidence shall be provided concerning the level of quality system certification associated with the supplier and/or manufacturer. This documentation shall include the Capability Statement associated with the Quality System Certification. 8.3 Quality Certification Program Tenderers shall provide details of their program to upgrade their Quality Certification to meet the requirements of ISO 9001. 9. Samples 9.1 Production Samples When requested, Tenderers shall submit a minimum of six (6) production samples of each item offered as part of the tender package. 10. Packaging and Marking 10.1 Safe Handling of Products The successful tenderer(s) shall take all necessary precautions to ensure safe handling of all products supplied. In particular: a) Individual pack sizes shall not weigh more than 20kg. b) Palletised goods shall be supplied on standard wooden pallets although specially designed pallets will be acceptable where additional stability is required. c) Palletised goods are to secured and stabilised with no overhang to facilitate unloading d) Goods requiring indoor storage shall not exceed 1100mm in height. Check this is the latest Process Zone version before use. Page 6 of 10 Specification ETS 01-03-01 Ver 1

10.2 Packages Lots Each packaged lot shall be marked with the following information: Manufacturers Name Order Release Authority/Order Number Contract No. Ergon Stock Code Item Description Pack Size Pack Weight 11. Service Performance Tenderers shall state: (a) (b) (c) the period of service achieved by the items offered within Australian service conditions; Australian electricity supply authorities who have a service history of the items proposed for use by the Purchaser. Contact names and phone numbers of relevant employees of those supply authorities who can verify the service performance claimed. 12. Reliability 12.1 Service Life Tenderers are required to comment on the reliability of the equipment and the performance of the materials offered for a service life of 25 years under the specified system and environmental conditions. 13. Training There is no requirement for training associated with this specification. 14. Environmental Considerations Suppliers are required to comment on the environmental soundness of the design and the materials used in the manufacture of the items offered. In particular, comments should address such issues as recyclability and disposability at the end of service life. 15. Information to be Provided 15.1 Specific Technical Requirements The specific technical requirements for the items shall be as stated in Attachment 1 of this specification. The tenderer shall fill in all data requested by Attachment 1 and shall guarantee such data. Check this is the latest Process Zone version before use. Page 7 of 10 Specification ETS 01-03-01 Ver 1

15.2 Checklist of Supporting Documentation Attachment 2 details a checklist of supporting technical documentation which is required to be submitted with the tender. Check this is the latest Process Zone version before use. Page 8 of 10 Specification ETS 01-03-01 Ver 1

16. Attachment 1 Technical Details NOTE: A separate schedule is to be provided for each item offered except where information common to all items which only needs to be provided once. PARTICULARS UNITS ITEM No. Manufacturer's Name and Address Place of Manufacture Manufacturer's Product Catalogue Number Grade of Material Galvanising Details: Method Applicable Australian Standard Minimum Coating Thickness µm Details of Oil used on Threads Pack Size Pack Weight kg SIGNATURE OF TENDERER: Check this is the latest Process Zone version before use. Page 9 of 10 Specification ETS 01-03-01 Ver 1

17. Attachment 2 Technical Document Checklist CLAUSE Ref. PARTICULARS UNITS Have full and comprehensive details been submitted WITH the tender documents associated with each of the following items? 8.2 Quality systems of BOTH the TENDERER and the MANUFACTURER 8.3 Tenderer's/Manufacturer's program to upgrade QA systems to ISO 9001 Yes/No Yes/No 9.1 Production Samples 11 Service Performance Yes/No 12 Reliability Yes/No p Training Materials (availability) Yes/No 14 Environmental Considerations (availability) Yes/No NAME OF TENDERER: ADDRESS OF TENDERER: SIGNATURE: FOR AND ON BEHALF OF TENDERER DATE: Check this is the latest Process Zone version before use. Page 10 of 10 Specification ETS 01-03-01 Ver 1