B. Following all applicable manufacturer s guidelines and application instructions shall be considered a requirement of this specification.

Similar documents
Section Pedestrian Traffic Coatings

SECTION CONCRETE TOPPING or SECTION DECORATIVE FINISHING or SECTION CEMENTITIOUS COATINGS

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating

SECTION Pedestrian Traffic Coatings{PRIVATE } 1.1 SUMMARY (Specification writer shall add, delete or amend, as deemed necessary)

SECTION CEMENTITIOUS AND REACTIVE WATERPROOFING SUMMARY (Specification writer shall add, delete or amend, as deemed necessary)

SECTION EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

ARDEX GUIDE SPECIFICATION ARDEX TRM Transportation Repair Mortar Fast-Setting Concrete Repair Mortar

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

A. This Section includes resinous flooring systems with epoxy body coat(s).

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

Section Shotcrete

1.1 Related Work Specified in Other Sections (Delete if Not Applicable):

SECTION HYDRAULIC CEMENT UNDERLAYMENT

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

1/16 Single Broadcast Polymer Flooring System

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

ARDEX GUIDE SPECIFICATION ARDEX FDM Full Depth Repair Mortar Concrete Repair Mortar with Corrosion Inhibitor

ARDEX GUIDE SPECIFICATION ARDEX SD-M Designer Floor Finish

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX ARDIFLO Pump System Underlayments

SECTION SURFACE-APPLIED CRYSTALLINE WATERPROOFING AND CONCRETE REPAIR

Florock Seamless Flooring Systems

RESINOUS FLOORING

SECTION A. American Society for Testing and Materials (ASTM):

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Underlayments and Toppings

FLEXMAR 3-Coat High-Build Colored Quartz System

Florock Seamless Flooring Systems

System Specification CEM-DYE 25 SYSTEM Division 9 Finishes Section Staining and Transparent Finish

SECTION A. American Society for Testing and Materials (ASTM):

SECTION CONCRETE PAVING SLABS SET IN MORTAR

ARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment

By CTS Cement Manufacturing Corp.

KOSTER AMERICAN CORPORATION

Section SECTION RESINOUS FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ARDEX GUIDE SPECIFICATION ARDEX GPS GENERAL PATCH & SKIMCOAT Trowelable underlayment

ReCote Finish System over Concrete

SECTION A. American Society for Testing and Materials (ASTM):

Florock Seamless Flooring Systems

SECTION LITHIUM BASED MOISTURE VAPOR CONTROL CURE SYSTEM AND FINISHING

System Specification CEM-DYE 250 SYSTEM Division 9 Finishes Section Staining and Transparent Finish

DIVISION 3 - CONCRETE Section Concrete Toppings Section Concrete Resurfacing Section Concrete Rehabilitation

Dryshake CSI Format Section 07160

SECTION Arisfor WallGuard

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX GUIDE SPECIFICATION ARDEX K 60 ARDITEX A Rapid Setting Latex Smoothing and Leveling Compound

Desco Granite Flooring Specifications

Tennant Company October North Lilac Drive Minneapolis, Minnesota Guide Specification

***********************************************************************************

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Florock Seamless Flooring Systems

Consult Sika Corporation (Industrial Flooring) for assistance in editing this section for the specific application.

SECTION HYDRAULIC CEMENT UNDERLAYMENT

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

SPECIAL SPECIFICATION 3289 High Friction Surface Treatment

SECTION ELASTOMERIC LIQUID FLOORING

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

DIVISION 7 THERMAL AND MOISTURE PROTECTION Section Traffic Coatings

SECTION EPOXY FLOORING SYSTEMS

DIVISION 3 - CONCRETE Section Concrete Toppings Concrete Resurfacing Concrete Rehabilitation

Seal- Krete High Performance System

SECTION STAMPED CONCRETE PAVING

Jewel Stone. Decorative Concrete Overlay System. Part 1 GENERAL MANUFACTURER S SPECIFICATION

Specifications. Specifications (Architectual) Metallic System. Metallic System

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

RESILIENT FLOORING: Select Step Wood

SECTION RESINOUS FLOORING

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

PRODUCT GUIDE SPECIFICATION

SECTION A. American Society for Testing and Materials (ASTM):

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

CONCRETE TILE PAVERS

SECTION HYDRAULIC CEMENT UNDERLAYMENT

GUIDE SPECIFICATION SECTION CRYSTALLINE WATERPROOFING

ARDEX GUIDE SPECIFICATION ARDEX K 521 Self-Leveling Concrete Topping with Aggregate Surface

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials

SECTION RESINOUS FLOORING

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

GUIDE SPEC SECTION Injection Grout (IG10)

SECTION Verrazzo Epoxy Mosaic Floor System

DIVISION 3 CONCRETE Section Concrete Rehabilitation

80657 StoColor Texture - Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

SECTION A. American Society for Testing and Materials (ASTM):

CSC SPECIFICATIONS DRY SHAKE CRYSTALLINE WATERPROOFING Section

CSI SPECIFICATIONS DRY SHAKE CRYSTALLINE WATERPROOFING Section

ARDEX GUIDE SPECIFICATION ARDEX K 22 F High Flow, Fiber Reinforced, Self-Leveling Underlayment

RESILIENT FLOORING: Hot and Heavy - Secoya

SECTION A. American Society for Testing and Materials (ASTM):

for Mortar-Set Concrete Tiling Installations

ChemMasters. Installation Guidelines ChemDeck, Water Resistant, Traffic Grade Resurfacing System for Horizontal Concrete

Contract Specs Version 1 Project XXX. SECTION xxxx STRENGTHENING OF CONCRETE WITH FRCM (FABRIC REINFORCED CEMENTITIOUS MATRIX) PART 1 - GENERAL

80201 StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Florock Seamless Flooring Systems

ARDEX GUIDE SPECIFICATION ARDEX PANDOMO Wall ARDEX PANDOMO W1 Decorative Wall Finishing Compound

Transcription:

Guide Specification Miracote MPC (Multipurpose Protective Coating) Cementitious Microtopping System (Specification writer shall choose the most appropriate section that applies to a given scope of wk, including but not limited to, the following listed sections) SECTION 03 01 30 RESURFACING OF CAST-IN-PLACE CONCRETE SECTION 03 01 40 RESURFACING OF PRECAST CONCRETE SECTION 03 01 50 RESURFACING OF CAST DECKS AND UNDERLAYMENT SECTION 09 97 26 CEMENTITIOUS COATINGS PART 1 GENERAL 1.1 SUMMARY A. Provide all lab, materials, equipment and supervision as necessary to install an architectural, decative, two-component, polymer-modified, cementitious microtopping system over (new and/ existing) hizontal, interi exteri concrete slab surfaces, as shown on the project drawings and as outlined in this specification. B. Following all applicable manufacturer s guidelines and application instructions shall be considered a requirement of this specification. C. Related Sections: (Specification writer shall add, delete amend, as deemed necessary) 1. Section 03 30 00 Cast-in-Place Concrete 2. Section 03 35 00 Concrete Finishing 3. Section 03 39 00 Concrete Curing 4. Section 07 92 00 Joint Sealants 1.2 REFERENCES (Specification writer shall add, delete amend, as deemed necessary) A. ASTM C109: Standard Test Method f Compressive Strength of Hydraulic Cement Mtars. B. ASTM C190: Method of Test f Tensile Strength of Hydraulic Cement Mtars.. C. ASTM C580: Standard Test Method f Flexural and Modulus of Elasticity of Chemical-Resistant Mtars, Grouts, Monolithic Surfacings, and Polymer Concretes. D. ASTM D4263: Standard Test Method f Indicating Moisture in Concrete by the Plastic Sheet Test Method. E. ASTM F1869-04: Standard Test Method f Measuring Moisture Vap Emission Rate of Concrete Subflo Using Anhydrous Calcium Chlide. F. ICRI Technical Guideline No.03732: Selecting and Specifying Concrete Surface Preparation f Sealers, Coatings, and Polymer Overlays. 1

1.3 SUBMITTALS (Specification writer shall add, delete amend, as deemed necessary) A. General: Submit (_) number of copies each of the following items in accdance with the requirements of the Conditions of Contract and in Division 1 Specification Sections. B. Product Data: Submit manufacturer s technical data sheets, any applicable installation guidelines recommendations, and material safety data sheets f each product included in this specification. C. Samples: F initial selection, submit manufacturer s standard col charts f review by the specification authity and owner s representative. F final selection, submit sample boards (specification writer shall specify sample size as deemed necessary) to exhibit pattern, texture, col and finish of the architectural, decative, cementitious microtopping system. If a clear coat sealer finish is desired, submitted sample boards shall also include same. D. Material certificates signed by the manufacturer certifying that the architectural, decative, twocomponent, polymer-modified, cementitious microtopping system complies with all requirements of the material specified herein. E. Warranty: Submit a sample of the manufacturer s standard material warranty. F. Contract Project Reference List: Contract shall submit a minimum of 5 recently completed projects of a similar nature and include total contract value of completed wk. 1.4 QUALITY ASSURANCE A. Manufacturer Qualifications: The manufacturer of the products specified in this section shall have a minimum of 5 years experience in the production of these types of products and systems. B. Contract Qualifications: The contract installing the products specified in this section shall have a minimum of 3 years experience and have successfully completed no less than 5 projects similar in scope and complexity, and is acceptable to and has been trained by the manufacturer. C. Substitutions: Requests f the approval of any product other than those specified in this section must be submitted to the specifying authity two weeks pri to the bid, and shall include complete application specifications and physical characteristics. Any request after this date will not be accepted. Failure of perfmance requires immediate removal and replacement of unapproved substituted material with those iginally specified at no cost to the owner, Architect, construction manager, general contract. D. Single Source System: All components of the completed microtopping floing system shall be, without exception, from a single manufacturer f the assurance of a seamless material warranty. 1.5 DELIVERY, STORAGE AND HANDLING A. Deliver materials in iginal packages and containers with seals unbroken and bearing manufacturer's labels containing brand name, batch lot numbers, and directions f stage and mixing with other components. B. Ste materials to comply with manufacturer's directions to prevent from damage and/ deteriation from moisture, heat, cold, direct sunlight, other detrimental effects. 1.6 PROJECT CONDITIONS A. Environmental Conditions: Comply with all the manufacturer's directions f maintenance of ambient and substrate temperature, moisture, humidity, ventilation, and other conditions required to execute and protect completed wk. In hot and cold weather conditions when high evapation rates adverse conditions may be expected, the contract will be responsible f the quality of the completed installation. When installing cementitious materials, follow all recommendations and guidelines of the American Concrete Institute, as published in ACI Committee 305 f Hot-Weather Concreting and ACI Committee 306 f Cold-Weather Concreting. B. Lighting: Permanent lighting will be in place and wking befe installing the two-component, polymer- 2

modified cementitious architectural microtopping system. C. Protection: Protect newly installed microtopping system from rain other potentially harmful climatic conditions f a minimum of 24 hours, from any potential damages due foot vehicular traffic, and/ from the wk of other trades. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Approved Manufacturer: Miracote Division of Crossfield Products Cp., 3000 E. Harcourt Street, Rancho Dominguez, CA 90221, (310) 886-9100; also 140 Valley Road, Roselle Park, NJ 07204, (908) 245-2800, www.miracote.com. 2.2 MATERIALS A. Cementitious Microtopping Material: Miracote MPC (Multipurpose Protective Coating) is a pre-packaged, two-component, polymer-modified, cementitious resurfacing system that is applied in a nominal thickness from 1/16 to 3/32 on to properly prepared, new existing, concrete substrates. (Specification writer shall add, delete amend, as deemed necessary to include other acceptable substrates such as, masonry, metal, wood and tile). One unit of Miracote MPC consists of one (1) five gallon pail of Liquid Catalyst, and two (2) 55# bags of dry powder available in choice of two cols, white and natural cement, and two grades, smooth and regular. B. Col Pigmentation: Miracote ColPax LIP f pigmenting Miracote MPC is available in 15 standard cols (includes capability to match any PMS cols) that are mixed with white powder to match published col charts. C. Architectural Stains: If desired, the optional application of Miracote Mirastain (water and co-polymer base stain) can be applied to the surface of the cured Miracote MPC resurfacing lieu of integral pigment packs, if pigmented, to further architecturally accent the finished system surface with additional col. D. Sealers and Finish Coats: Numerous compatible Miracote clear sealers and finish coats are available depending on job site and exposure conditions. (Specification writer should consult with Miracote representative technical service f appropriate recommendations and product selection) 2.3 PROPERTIES A. Physical Properties of Cementitious Microtopping Material: Provide a two-component only, polymer-modified, cementitious microtopping system that meets exceeds the listed minimum physical property requirements when tested in accdance with the referenced standard test method. Two Component System Compressive Strength (ASTM C 109): Tensile Strength (ASTM C 190): Flexural Strength (ASTM C 580) Adhesion (MIL-D-3134, Para.4.7.14): Liquid Polymer and Bagged Powder 2,440 psi 450 psi 2,415 psi 515 psi Water Absption (ASTM C 642) 1.61% volume of permeable voids 5.07% Water Vap Permeability (ASTM E 96 1.96 perms/inch Impact Resistance: (MIL-D-3134) Para. 4.7.3 No cracking detachment (2# steel ball dropped from 8 height onto coated steel plate) 3

PART 3 - EXECUTION 3.1 EXAMINATION A. Examine all concrete other substrates and conditions where the architectural cementitious microtopping system is to be installed. Notify the Specifying Authity of any unsatisfacty conditions that may be detrimental to the proper and timely completion of the wk. B. Do not proceed with the wk until all such deficiencies have been crected by the Contract in an acceptable manner, and as approved by the Specifying Authity. 3.2 PREPARATION A. Protect all surrounding areas, walls, window glass, landscaping and other adjacent surfaces from the execution of each item of wk including, but not limited to, surface preparation and all application steps of the cementitious microtopping installation. B. Perfm surface and crack repairs as necessary to re-profile, re-level to reste the integrity of the concrete substrate in general, as directed by the specifying authity. Concrete surface repair products shall be from the same manufacturer, as approved by the manufacturer of the concrete microtopping system specified herein. Provide letter from the manufacturer of the surface repair materials verifying compatibility with all the specified architectural resurfacing components. C. Architectural cementitious microtopping system must be applied to a clean, sound and mechanically prepared concrete substrate to a minimum (Specification writer shall choose between CSP-3 to CSP-5) surface profile, in accdance with the International Concrete Repair Institutes (ICRI) Technical Guideline 03732, Selecting and Specifying Concrete surface Preparation f Sealers, Coatings and Polymer Overlays. D. (As an optional requirement f this project document the specification writer can include the following when deemed necessary) Contract shall perfm tensile bond tests, as directed by the Specification Authity, in accdance with International Concrete Repair Institutes (ICRI) Technical Guideline 03739, Guide to Using In-Situ Tensile Pull-Off Tests to Evaluate Bond of Concrete Surface Materials. 3.3 APPLICATION A. General: Follow all manufacturers directions, as published in their product technical data sheets and/ available installation guidelines regarding the application of the decative cementitious microtopping system, as specified herein. B. Substrate Conditioning: Dampen substrate with potable water only. Maintain substrate at saturated surface dry (SSD) condition with no standing water puddles during the placement of the base coat. C. Priming: Not required f the installation. Base coat of the cementitious resurfacing material must be applied over a saturated surface dry (SSD) concrete substrate. D. Cementitious Microtopping: Install architectural two-component, polymer-modified, cementitious microtopping system in strict confmance to the most current version of the manufacturer s published installation guidelines and technical instructions. Mix and spread microtopping material onto substrate with magic trowels, hand trowels, squeegees, rollers other acceptable placement tools in two me coats depending on traffic, exposure conditions as specified herein. A wet edge shall be maintained at all times while placing freshly mixed cementitious resurfacing materials. The finished resurfacing installation shall have a unifm thickness of 1/16 to 3/32 f a three coat microtopping system foundation. E. Apply Miracote Mirastain after the final microtopping has cured sufficiently when visibly dry and when surface can be walked on without damage. The col(s), dosage rates, method of application, and number of application steps of staining process shall be determined as per the approved submittal boards and job site mock-up. 4

F. F ease of maintenance, protection of the surface and col retention, the finished Miracote MPC Microtopping system shall be sealed with a clear acrylic urethane epoxy similar finish coat, as manufactured by Miracote (specification writer shall specify suitable sealer coating, as determined in Section 2.2-D). 3.4 CLEANING A. Clean wk area and remove/discard all debris resulting from the application of the cementitious microtopping system to the acceptance of the specifying authity the owner. 3.5 PROTECTION A. Protect all completed wk of the application during the specified cure time of the material from vehicular pedestrian traffic, any exposure to solid liquid spillage any other fm of contamination. END OF SECTION 5