Lenntech. Tel Fax

Similar documents
DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

DOW Ultrafiltration. Case History. DOW Ultrafiltration Membranes Offer Reliable, Economical Answer to High Solids

FILMTEC Membranes System Design: Introduction

Location: Purpose: Time in Operation: Performance:

Lenntech. Tel Fax

FILMTEC Membranes. FILMTEC Membranes Reclaim Waste Water at 86% Recovery in Singapore. Case History

DOW Specialty Membrane XUS and XUS Reverse Osmosis Elements

FILMTEC Membranes. Case History. Retrofitting Hollow Fiber Elements with Spiral Wound RO Technology in Agragua, Spain

FOSSIL POWER PLANT WATER TREATMENT. Generating optimal performance, powered by Dow.

THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS

Dow Water Solutions. FILMTEC Membranes. Product Information Catalog

Key words: Integrated Membrane System, IMS, Seawater Reverse Osmosis, SWRO, SW30HRLE- 400, Ultrafiltration, UF, ZeeWeed 1000

DOWEX Ion Exchange Resins

FILMTEC Membranes How FILMTEC Seawater Membranes Can Meet Your Need for High-Pressure Desalination Applications

FILMTEC Membranes How FilmTec s New High-Rejection, Low-Energy Seawater Element Can Reduce Your Desalination Costs

Lenntech. Using EDI to Meet the Needs of Pure Water Production. EDI Process. Summary. Introduction

Lenntech. Tel Fax DOW FILMTEC Membranes. Tech Fact

FILMTEC Membranes. Tech Manual Excerpts. Principle of Reverse Osmosis. Figure 1: Overview of Osmosis / Reverse Osmosis

NIPPON PAPER RO SYSTEM + 2 Others

HEAVY INDUSTRY PLANT WASTEWATER TREATMENT, RECOVERY AND RECYCLE USING THREE MEMBRANE CONFIGURATIONS IN COMBINATION WITH AEROBIC TREATMENT A CASE STUDY

Water Treatment Solutions A - Z

Operating parameters influencing Ultrafiltration of organic model solutions

WATER PURIFICATION FOR INDUSTRY

WASTE WATER RECYCLE MANAGEMENT ION EXCHANGE INDIA LTD

Sulaibiya world s largest membrane water reuse project

Total Water Management in Thermal Power Station By Mr. N. Ramachandran - Associate Vice President (Technology)

Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources

Nadeem Shakir Qatar Petroleum. The 2nd Joint Qatar Japan Environmental Symposium, QP JCCP The 21st Joint GCC Japan Environmental Symposium

Treating Heavy Oil Wastewater for Beneficial Use by Integrated Technology of Bio-Oxidation and RO

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

REQUEST FOR PROPOSALS DESAL ANTISCALANT/CLEAN-IN-PLACE CHEMICALS BID NO: ADDENDUM 1

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager

ACUMER ACUMER 4450 ACUMER 4800

27 th ANNUAL WATEREUSE SYMPOSIUM CHALLENGES OF HIGH-SULFATE WASTEWATER RECYCLE. Abstract. Introduction

POREX Tubular Membrane Filter (TMF ) Applied in a ZLD System as Critical Solid/Liquid Separation Process

OsmoBC Integrated Membrane Systems

Lenntech. Dow Liquid Separations. DOWEX Ion Exchange Resins. The Advantages of Uniform Particle Sized Ion Exchange Resins.

"Significant Cost Savings Obtained Using Advanced Membrane Systems for Cooling Tower Water Treatment and in ZLD plants

using EDI to meet the needs of pure water production

Use of Spiral Wound UF in RO Pretreatment

Continuous Water Recycling For Reusable Plastic Containers

Containerized Ultrafiltration (UF) Water Treatment Plant

Membrane Technology: From Manufacture to. May Production

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent

Reverse Osmosis. Lecture 17

PURPOSE PROCESS PAYOFF

Peculiar or unexpected behavior of Silt Density Index of pretreated seawater for RO desalination

Case History. Solves Leakage Problems and Improves Energy Efficiency in Semiconductor Plant

Addressing increasing wastewater volumes in industrial and oil & gas operations using thermal systems

OPTIDOSE 1000 Traceable Polymer A Tool for Maintaining Maximum Heat Transfer

Recovery and reuse of water from effluents of cooling tower

DOW TM Ultrafiltration

Pretreatment of Industrial Wastewater for ZLD/Resources Recovery

Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India - Reducing the water footprint in coal fired power plants -

ULTRAFILTRATION FOR REVERSE OSMOSIS-PRETREATMENT

BOOMERANG FROM BIO-EFFLUENT TO POTABLE WATER

AL-KAWTHER INDUSTRIES LTD

Cartwright Consulting Co.

Reduction of fresh water intake by desalination. Raymond Creusen (TNO)

The evolution of high purity water production

Beer Filtration Solutions Your Partner for All Your Filtration Needs

Reverse Osmosis. Background to Market and Technology

Cartwright Consulting Co.

Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India Reducing the water footprint in coal fired power plants

Texas Desal 2017 NEXED EDR Technology Demonstration 22nd September Evoqua Water Technologies LLC

AIChE Industrial Water Reuse. Applying Advanced Technologies to Reuse Applications Erik Hanson Director of Product Management, Systems

Sustainable Water Management for the Power Industry

FILMTEC Membrane Element Analysis

Solutions Industry pioneers in spiral membrane technology

2018 MAY PAC Water Treatment

Petro-Canada Re-Uses Treated Edmonton Waste Water. Coking.com Safety Seminar Calgary September 2008

CeraMem. Ceramic Membrane Technology. Advanced Heavy Metals Removal System WATER TECHNOLOGIES

Reverse Osmosis and Nano-filtration Innovation for Water Re-use

Treatment and Reuse of Tannery Waste Water by Embedded System

WATER RECYCLING PLANT IN WAFRA. Feras Al Salem

Protegra CS RO Series. Meeting All Your Pure Water Demands. Water Technologies

Dow Liquid Separations. DOWEX MARATHON 11 Ion Exchange Resin. Engineering Information. March 2006

FEDI. Fractional Electrodeionization. The evolution of high purity water production

POREX Tubular Membrane Filter (TMF ) Applied in a Plastic Plating Wastewater Reclaim System

Hollow Fiber and Tubular UF Pilot Testing Procedures & Case Studies

Flootech. General Presentation. Power Industry. Flootech Oy 2012

Lenntech. Ion Exchange Resin Analysis Kit. DOW Ion Exchange Resins DIRECTOR SM Service

Water supplied by Marafiq does not meet the process requirements.

Ultrafiltration Technical Manual

Water Recycle as a Sustainability Tool for Industrial Plants

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

Boiler Water Treatment

LIFE projects technical conference: Coordinating beneficiary: Associated beneficiaries:

Application solution ph: * (1 %, 20 C, 0 d water) P3-ultrasil 73 is, under the application conditions described below, compatible with

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50%

KEYWORDS: Ion exchange, compressed short bed, wastewater, filter, secondary water, tertiary water, reverse osmosis (RO), electrodeionization (EDI).

Treated Effluent (TSE) Reuse Applications and Challenges. Saudi Arabia

Dow Liquid Separations. FILMTEC Elements. An Overview of Products, Applications, and Technical Resources

Membrane Technique MF UF NF - RO

Water Treatment in Hotels and Resorts

Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned

Make Water Anywhere with Pall Integrated Membrane Systems

Summary of Pilot Plant Results and Preliminary Recommendations

Transcription:

Case History Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Site Information Location: Beijing, China Capacity: Second Phase, 150m 3 /h; Third Phase, 160m 3 /h Time in Operation: Second Phase 2004 Third Phase - 2006 Waste Water Source: Cooling Tower Blowdown, Power Plant UF/RO Module Installed: DOW Ultrafiltration SFP2660 DOW FILMTEC BW30-365FR DOW FILMTEC BW30-400 Challenges: High scaling Potential for RO Skids DOW FILMTEC Membranes BW30-365FR, BW30-400 and DOW Ultrafiltration SFP2660 Cooling Tower Blowdown Reuse in Gaojing Power Plant Figure 1: Snapshot of Gaojing Powerplant Project Background Constructed in the 1960s by Datang Corporation, and located in Mengtougou, the Gaojing Power Plant is one of the earliest power plants in Beijing. For the past 40 years, the Gaojing Power Plant has supplied 6 X 100 MW/hr of heat and electricity to its local communities and industries. In 2003, with increasing environmental requirements from the government, the plant, using membrane technology, started to reuse the blowdown from their cooling towers as the feed to its eight boilers. OMEX Environmental, a wholly owned subsidiary of The Dow Chemical Company, supplied three phases of wastewater reuse system, with productivity of 60m 3 /h, 150m 3 /h and 160m 3 /h, respectively. In the second phase, an integrated solution of ultrafiltration (UF), reverse osmosis (RO), and electrodeionization (EDI) was applied; while in the third phase, dual membrane process with UF and RO was adopted after clarifications. Page 1 of 6 Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-02176-0809

Typical Compositions of the Cooling Tower Blowdown Item Average ph 8.65~8.86 Suspended Solid (SS) (mg/l) 8.8 ~25.4 Conductivity (µs/cm) 1620~2790 COD Mn (mg/l) 5.18~12.14 Total Hardness (mmol/l) 10.25~16.1 Cl - (mg/l) 182~336 M-Alkalinity (mmol/l) 4.86~7.2 P- Alkalinity (mmol/l) 0.39~0.64 2- SO 4 (mg/l) 186.33~407.88 SiO 2 (mg/l) 11.8~33.4 Table 1: Average water quality of the blowdown in 2008 Table 1 shows the average water quality of the blowdown during 2008. Starting from May 2007, the source of cooling tower makeup has been changed from surface water to secondary effluent from the Gaobeidian Municipal Wastewater Treatment Plant. It can be seen from Table 1 that the waste stream contained high hardness, alkalinity, SO42- and silicon dioxide at times, which are typical characteristics of cooling tower blowdown. In addition to this, the concentrations of different contaminants varied substantially with seasons and cooling tower makeup quality. These high scaling potential and unstable properties could cause problems in the subsequent waste water reuse systems. Process Flow and Key Treatment Units An illustration of the process flow in the second phase reuse system is shown in Figure 2. The blowdown water was first pumped into a multi-media filter to remove suspended solids and reduce the turbidity from over 20 NTU to around 4-8 NTU. Then the UF unit further decreased the turbidity to less than 0.4 NTU and protected the subsequent RO unit from colloids, suspended solids, bacteria and large molecular weight organics. Reducing agents, anti-scalant and acid were then dosed before the first pass RO system, in which most of the dissolved solids and SiO 2 were removed. The permeate water from the first pass RO was then degasified, and the ph was increased to 9.5 by NaOH dosing before entering the second pass RO. In the end, EDI was installed for final demineralization to meet the requirement of boiler make up. MMF UF First Pass RO Degasifier Second Pass RO EDI Boiler Make up Figure 2: Process Flow of the second phase reuse system Page 2 of 6 Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-02176-0809

The key treatment units in the second phase reuse system are listed in Table 2 and shown in Figure 3. Facility Capacity m3/h Capacity Per Train m 3 /h No. of Trains Multi-media Filter 270 270 1 Disk Filter 235 117.5 2 UF 235 117.5 2 First Pass RO 186 93 2 Second Pass RO 167 83.5 2 EDI 150 75 2 Table 2: System information on unit operations of the second phase Figure 3: Pictures of the key treatment units System Performance The performance of the reuse systems in the year 2008 are described in this section. Figure 4 plots the silt density index (SDI) of the UF permeate compared to time for both phases of the reuse system. For the third phase system, a constant SDI value less than three (usually around 2.5) indicated a good and stable UF operation performance. In the second phase, however, the SDI value varied from three to four, probably due to higher turbidity of the UF influent of the second phase. After approximately five years of operation, the UF membrane is still able to produce quality water that meets the required RO feed water quality. Page 3 of 6 Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-02176-0809

System Performance, continued SDI 4 3.5 3 2.5 2 1.5 1 0.5 0 p 2nd Phase 3nd Phase Figure 4: SDI of UF permeate (Second and third phase) The salt rejection rate of the first pass RO was stable at between 97 percent and 98 percent, while that of the second pass varied from 71 percent to 93 percent, as shown in Figure 5. This is due to the fact that the conductivity of the second pass RO was as low as 40-80us/cm. The conductivity is in many cases the most important quality parameter of the product water. Since carbon dioxide is not rejected by the membrane, it is present in the product water, where it reacts to form carbonic acid and causes the conductivity to increase. The passage of carbon dioxide can be prevented by adjustment of the feed water ph to RO to a value of about 8.2. At this ph, most carbon dioxide is converted into hydrogen carbonate, which is rejected well by the membrane. The problem could also be solved by the installation of degasifier, as was the case in the Gaojing Power Plant. 1.1 1 Salt Rejections 0.9 0.8 0.7 0.6 0.5 1st Pass RO 2nd Pass RO 0.4 Figure 5 Salt Rejections of the RO units (Second phase) The recoveries of the two-pass RO systems were 75 percent and 90 percent, respectively. For the second phase system with EDI after the RO system, the effluent resistance increased to above 14 MΩ-cm. Page 4 of 6 Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-02176-0809

System Performance, continued UF could only remove a very small portion of the organics, with effluent COD Mn around four to eight mg/l into the RO systems. The first pass RO unit was able to reduce COD level to below two mg/l, with rejection rate around 70 to 80 percent; however in the second pass, the RO unit almost could not further remove any organics, as shown in Figure 6. It indicated that the organics passed the first pass RO probably had small molecular weight less than the molecular weight cut-off (MWCO) of the RO element. 10 CODMn (mg/l) 8 6 4 2 1st Pass RO Feed 1st Pass RO Permeate 2nd Pass RO Permeate 0 Figure 6: COD Removal Rate in RO system (Second phase) NaOH was dosed in the first pass RO effluent to increase ph of the second pass RO influent. It also helped to increase silica rejection of the second pass RO, as shown in Figure 7. The silica level could be controlled below 10 parts per billion (ppb) in RO permeate. Then, EDI further reduced silica to less than three ppb. 1 0.995 0.99 0.985 0.98 0.975 0.97 0.965 0.96 Figure 7: Silica Rejections in second pass RO Page 5 of 6 Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-02176-0809

Chemical Dosing and Cleaning Process Oxidant dosed in UF influent and backwash water to prevent biological growth Reduce agent dosed in RO feed to protect RO from oxidation, dosage controlled by online ORP monitor Anti-scalant dosed in RO feed to avoid CaCO3CaSO4 scaling ph adjustment between first and second pass RO UF unit was back washed every 30 minutes with air scrub every five hours. Clean in place (CIP) was performed every three months. RO unit was cleaned at ph 12 first and then at ph 2 in 30º C. The CIP frequency was once per month. Conclusion Water recycling systems for cooling tower blowdown have become more and more common in fossil fuel power plants because of the large volume (about 60 percent of all wastewater comes from power plants). The main technical challenge is that this water stream is very unstable with high hardness, HCO 3 - concentration, silicon content, SO 4 2- and sometimes COD. High salt content and unstable ph properties make cooling tower blowdown water a difficult type of wastewater to reuse. Dow s experience in membrane technology offers innovative solutions to guide application development in this area. As in the case of Gaojing Power Plant, dual membrane technology together with proper pretreatment and chemical dosing helped to realize more than 70 percent reuse of the cooling tower blowdown. Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system. Notice: No freedom from any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer s use and for ensuring that Customer s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to Dow or the Company mean The Dow Chemical Company and its consolidated subsidiaries unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Page 6 of 6 Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow Form No. 609-02176-0809