mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Similar documents
mortarless masonry Design Manual Part 1 (BS 5628:2005) Section 1 Page 1 BS 5628:2005 CODE OF PRACTICE FOR THE USE OF MASONRY

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

mortarless Design Manual Part 3 (AS 3600:2009) Section 2 Page: DESIGN OF WALLS FOR AXIAL COMPRESSION USING SIMPLIFIED DESIGN METHOD

Contents. Foreword 1 Introduction 1

Chapter 2 Notation and Terminology

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Contents. 1.1 Introduction 1

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

BS EN :2004 EN :2004 (E)

GATE SOLVED PAPER - CE

VARIOUS TYPES OF SLABS

Sabah Shawkat Cabinet of Structural Engineering 2017

Flexure and Serviceability Limit State

Chapter. Masonry Design

UNIT-I DESIGN CONCEPTS, DESIGN OF BEAMS Part - A (Short Answer Questions)

Design of Reinforced Concrete Slabs

DESIGN OF RC ELEMENTS UNIT 1 PART-A

PRESTRESSED CONCRETE STRUCTURES UNIT I INTRODUCTION THEORY AND BEHAVIOUR

COLUMNS. Classification of columns:

ST7008 PRESTRESSED CONCRETE

CHAPTER 3 BEHAVIOUR OF FERROCEMENT HOLLOW SLABS

Strength Design of Reinforced Concrete Structures

Reinforced Concrete Design. Lecture no. 1

Analysis and Design of Steel

CHAPTER 2. Design Formulae for Bending

DESIGN OF WALLS FOR SHEAR

REINFORCED CONCRETE DESIGN

twenty two concrete construction: flat spanning systems, columns & frames ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN

6. Design of Portal Frames (For class held on 20 th, 26 th and 27 th March 07)

Ce 479 Reinforced Masonry Fall 2005

CIVIL ENGINEERING YEAR QUESTION BANK

ARCH 331. Study Guide for Final Examination

DS/EN DK NA:2013

A COMPARATIVE STUDY OF PROBABILITY OF FAILURE OF CONCRETE IN BENDING AND DIRECT COMPRESSION AS PER IS 456:2000 AND AS PER IS 456:1978

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Pronto Block Walls. Structural Design Manual AS 3600:2009. masonry. style and function

twenty two concrete construction: flat spanning systems, columns & frames Reinforced Concrete Design Reinforced Concrete Design

Design of Composite Bridges Use of BS 5400: Part 5: 1979

10-COLUMNS: 10.1 Introduction.

Concrete Design Guide

Principles of STRUCTURAL DESIGN. Wood, Steel, and Concrete SECOND EDITION RAM S. GUPTA. CRC Press. Taylor& Francis Group

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

SOUTH AFRICAN NATIONAL STANDARD

SECTION 1. AS MASONRY STRUCTURES CODE

twenty two concrete construction: flat spanning systems, columns & frames Reinforced Concrete Design Reinforced Concrete Design

Structural use of concrete

Code Requirements for Nuclear Safety-Related Concrete Structures (ACI ) and Commentary An ACI Standard

CHAPTER 3 LOADS AND MATERIALS. 3.1 Introduction

OXFORD ENGINEERING COLLEGE (NAAC Accredited with B Grade) Department of Civil Engineering LIST OF QUESTIONS

CADS A3D MAX. How to model shear walls

Analysis and Design of One-way Slab System (Part-I)

3.4.2 DESIGN CONSIDERATIONS

Recommendations for additional fire protection of structural elements

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

2012 IBC/2011 MSJC MASONRY CODE COMPILATION

1 Prepared By:Mr.A.Sathiyamoorthy, M.E., AP/Civil

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

1.6 Concrete (Part II)

Questions with Solution

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

Seismic Performance of Hollow-core Flooring: the Significance of Negative Bending Moments

UNIT IVCOMPOSITE CONSTRUCTION PART A

SEISMIC ANALYSIS AND DESIGN OF A COMMERCIAL BUILDINGS (G+5) KORITALA SINDHUJA 1*, Mr. R.RATTAIAH 2*

Modjeski and Masters, Inc. Consulting Engineers 04/18/06 St. Croix River Bridge 3D Analysis Report Introduction

Seismic Analysis And Design of a Commercial Buildings (G+5)

5.4 Analysis for Torsion

HOW TO DESIGN CONCRETE STRUCTURES Columns

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE) UNIT-5 FOOTINGS & STAIRS

Introduction to Masonry Materials and Assemblages

Module 2. Philosophies of Design by Limit State Method. Version 2 CE IIT, Kharagpur

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

This final draft of the fib MC2010 has not been published; it is intended only for the purpose of voting by the General Assembly.

Unit 48: Structural Behaviour and Detailing for Construction. Limit State Design

System Assemblies & Load Tracing

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2019 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Steel, concrete and composite bridges

HISTORICAL REVIEW OF MASONRY STANDARDS IN NEW ZEALAND

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

APPENDIX B ABC STRUCTURES DESIGN GUIDE

CLT Structural Design Sylvain Gagnon, Eng. February 8, 2011 Vancouver

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

Modelling of RC moment resisting frames with precast-prestressed flooring system

Austral Deck Design for Construction Loading. Permanent formwork and Span capability

MASONRY WALL DATA: Wall Height = ft. Nominal Wall Thickness = 8.00 in. Depth to c.g. Steel, Wall = 3.81 in.

NCMA TEK. TEK 14-5A Structural (2006) LOADBEARING CONCRETE MASONRY WALL DESIGN

Technical Notes on Brick Construction Brick Industry Association Commerce Park Drive, Reston, Virginia 20191

NON ENGINEERED REINFORCED CONCRETE BUILDINGSS

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

UNIT-1 RETAINING WALLS

Flexural Analysis and Design of Beams. Chapter 3

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Level 6 Graduate Diploma in Engineering Structural analysis

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Technical Notes 24C - The Contemporary Bearing Wall - Introduction to Shear Wall Design [Sept./Oct. 1970] (Reissued May 1988)

4.6 Procedures for Connections

Comparison of One-way and Two-way slab behavior. One-way slabs carry load in one direction. Two-way slabs carry load in two directions.

SEISMIC ANALYSIS AND DESIGN OF A APARTMENT BUILDINGS (G+10) KAKARAPARTHY SIVA KARTHIK 1*, Mr. A.SRINIVASU 2*

pren : Redraft 9A

CD 360 Use of Compressive Membrane Action in Bridge Decks

Transcription:

SECTION 1. mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 1.1 Overview of IS 456:2000 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE IS 456:2000 is the current Indian Standard for the design of reinforced concrete. This is a 97 page document covering all aspects of design of reinforced concrete structures. The Standard is arranged in the following Sections and all Parts used in the preparation of the design aids in this manual are highlighted: Section 1 General Part 1. Scope Part 2. References Part 3. Terminology Part 4. Symbols Section 2 Materials, Workmanship, Inspection and Testing Part 5. Materials 5.1 Cement 5.2 Mineral Admixtures 5.3 Aggregates 5.4 Water 5.5 Admixtures 5.6 Reinforcement 5.7 Storage of Materials Part 6. Concrete 6.1 Grades 6.2 Properties of Concrete Part 7. Workability of Concrete Part 8. Durability of Concrete 8.1 General 8.2 Requirements for Durability Part 9. Concrete Mix Proportioning 9.1 Mix Proportion 9.2 Design Mix Concrete 9.3 Nominal Mix Concrete Part 10. Production of Concrete 10.1 Quality Assurance Measures 10.2 Batching 10.3 Mixing Part 11. Formwork 11.1 General 11.2 Cleaning and Treatment of Formwork 11.3 Stripping Time Part 12. Assembly of Reinforcement Part 13. Transporting, Placing, Compaction and Curing 13.1 Transporting and Handling

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 2 13.2 Placing 13.3 Compaction 13.4 Construction Joints and Cold Joints 13.5 Curing 13.6 Supervision Part 14. Concreting under Special Conditions 14.1 Work in Extreme Weather Conditions 14.2 Under-Water Concreting Part 15. Sampling and Strength of Designed Concrete Mix 15.1 General 15.2 Frequency of Sampling 15.3 Test Specimen 15.4 Test Results of Sample Part 16. Acceptance Criteria Part 17. Inspection and Testing of Structure Section 3 General Design Considerations Part 18. Bases for Design 18.1 Aim of Design 18.2 Methods of Design 18.3 Durability, Workmanship 18.4 Design Process Part 19. Loads and Forces 19.1 General 19.2 Dead Loads 19.3 Imposed Loads, Wind Loads and Snow Loads 19.4 Earthquake Forces 19.5 Shrinkage, Creep and Temperature Effects 19.6 Other Forces and Effects 19.7 Combination of Loads 19.8 Dead Load Counteracting Other Loads and Forces 19.9 Design Load Part 20. Stability of the Structure 20.1 Overturning 20.2 Sliding 20.3 Probable Variation in Dead Load 20.4 Moment Connection 20.5 Lateral Sway Part 21. Fire Resistance Part 22. Analysis 22.1 General 22.2 Effective Span 22.3 Stiffness 22.4 Structural Frames 22.5 Moment and Shear Coefficients for Continuous Beams 22.6 Critical Sections for Moment and Shear 22.7 Redistribution of Moments

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 3 Part 23. Beams 23.0 Effective Depth 23.1 T-Beams and L-Beams 23.2 Control of Deflection 23.3 Slenderness Limits for Beams to Ensure Lateral Stability Part 24. Solid Slabs 24.1 General 24.2 Slabs Continuous over Supports 24.3 Slabs Monolithic with Supports 24.4 Slabs Spanning in Two Directions at Right Angles 24.5 Loads on Supporting Beams Part 25. Compression Members 25.1 Definitions 25.2 Effective Length of Compression Members 25.3 Slenderness Limits for Columns 25.4 Minimum Eccentricity Part 26. Requirements Governing Reinforcement and Detailing 26.1 General 26.2 Development of Stress in Reinforcement 26.3 Spacing of Reinforcement 26.4 Nominal Cover to Reinforcement 26.5 Requirements of Reinforcement for Structural Members Part 27. Expansion Joints Section 4 Special Requirements for Structural Members and Sections Part 28. Concrete Corbels 28.1 General 28.2 Design Part 29. Deep Beams 29.1 General 29.2 Lever Arm 29.3 Reinforcement Part 30. Ribbed, Hollow Block or Voided Slab 30.1 General 30.2 Analysis of Structure 30.3 Shear 30.4 Deflection 30.5 Size and Position of Ribs 30.6 Hollow Blocks and Formers 30.7 Arrangement of Reinforcement 30.8 Precast Joists and Hollow Filler Blocks Part 31. Flat Slabs 31.1 General 31.2 Proportioning 31.3 Determination of Bending Moment 31.4 Direct Design Method 31.5 Equivalent Frame Method 31.6 Shear in Flat Slab 31.7 Slab Reinforcement

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 4 31.8 Openings in Flat Slabs Part 32. Walls 32.1 General 32.2 Empirical Design Method for Walls Subjected to In-plane Vertical Loads 32.3 Walls Subjected to Combined Horizontal and Vertical Forces 32.4 Design for Horizontal Shear 32.5 Minimum Requirements for Reinforcement in Walls Part 33. Stairs 33.1 Effective Span of Stairs 33.2 Distribution of Loading on Stairs 33.3 Depth of Section Part 34. Footings 34.1 General 34.2 Moments and Forces 34.3 Tensile Reinforcement 34.4 Transfer of Load at the base of column 34.5 Nominal Reinforcement Section 5 Structural Design (Limit State Method) Part 35. Safety and Serviceability Requirements 35.1 General 35.2 Limit State of Collapse 35.3 Limit State of Serviceability 35.4 Other Limit States Part 36. Characteristic and Design Values 36.1 Characteristic Strength of Materials 36.2 Characteristic Loads 36.3 Design Values 36.4 Partial Safety Factors Part 37. Analysis 37.1 Analysis of Structure Part 38. Limit State of Collapse: Flexure 38.1 Assumptions Part 39. Limit State of Collapse: Compression 39.1 Assumptions 39.2 Minimum Eccentricity 39.3 Short Axially Loaded Members in Compression 39.4 Compression Members with Helical Reinforcement 39.5 Members Subjected to Combined Axial Load and Uniaxial Bending 39.6 Members Subjected to Combined Axial Load and Biaxial Bending 39.7 Slender Compression Members Part 40. Limit State of Collapse: Shear 40.1 Nominal Shear Stress 40.2 Design Shear Strength of Concrete 40.3 Minimum Shear Reinforcement 40.4 Design of Shear Reinforcement 40.5 Enhanced Shear Strength of Sections Close to Supports

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 5 Part 41. Limit State of Collapse: Torsion 41.1 General 41.2 Critical Section 41.3 Shear and Torsion 41.4 Reinforcement in Members Subjected to Torsion Part 42. Limit State of Serviceability: Deflection 42.1 Flexural Members Part 43. Limit State of Serviceability: Cracking 43.1 Flexural Members 43.2 Compression Members Annex A List or Referred Indian Standards Annex B Structural Design (Working Stress Method) B-1 General B-1.1 General Design Requirements B-1.2 Redistribution of Moments B-1.3 Assumptions for Design of Members B-2 Permissible Stresses B-2.1 Permissible Stresses in Concrete B-2.2 Permissible Stresses in Steel Reinforcement B-2.3 Increase in Permissible Stresses B-3 Permissible Loads in Compression Members B-3.1 Pedestals and Short columns with Lateral Ties B-3.2 Short Columns with Helical Reinforcement B-3.3 Long Columns B-3.4 Composite Columns B-4 Members Subjected to Combines Axial Load and Bending B-4.1 Design Based on Uncracked Section B-4.2 Design Based on Cracked Section B-4.3 Members Subjected to Combined Direct Load and Flexure B-5 Shear B-5.1 Nominal Shear Stress B-5.2 Design Shear Strength of Concrete B-5.3 Minimum Shear Reinforcement B-5.4 Design of Shear Reinforcement B-5.5 Enhanced Shear Strength of Sections Close to Supports B-6 Torsion B-6.1 General B-6.2 Critical Sections B-6.3 Shear and Torsion B-6.4 Reinforcement in Members Subjected to Torsion Annex C Calculation of Deflection C-1 Total Deflection C-2 Short-Term Deflection C-3 Deflection Due to Shrinkage C-4 Deflection Due to Creep Annex D Slabs Spanning in Two Directions D-1 Restrained Slabs D-2 Simply Supported Slabs Annex E Annex F Effective Length of Columns Calculation of Crack Width

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 6 Annex G Moments of Resistance for Rectangular and T-Sections G-1 Rectangular Sections G-1.1 Sections without Compression Reinforcement G-1.2 Sections with Compression Reinforcement G-2 Flanged Sections Annex H Committee Composition

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 7 1.2 Scope of IS 456:2000 IS 456:2000 deals with the use of plain and reinforced concrete. For the purposes of the Standard plain concrete structures are those where the reinforcement, if provided, is ignored for the determination of strength of the structure. (1.1 and 1.1.1) This is precisely the approach taken for the design of mortarless walls in axial compression. There is no Indian reinforced masonry Code at present however it is appropriate to design mortarless walls in accordance with the provisions of the Concrete Code. There are subtle differences between the reinforced masonry codes and concrete codes in other countries, the main difference being that the minimum reinforcement requirements in the concrete codes are significantly greater as are the design strengths. When making calculations for the load tables in this manual a small portion of the face shells of the blocks has been taken as acting compositely with the core fill concrete. The design thickness of the wall is the core filled thickness t d as tabulated in Section 1 of Parts 2a, 2b and 3. It is this thickness also that has been used when calculating slenderness ratios. The core fill concrete in any wall must be of compressive strength at least equal to the unconfined compression strength of the blocks. For the purposes of the strength calculation in the design aids in this manual however an f ck of at least the strength of the blocks plus 5Mpa has been assumed. This is the minimum grout strength for mortarless masonry construction designed using the tables and diagrams in this manual. 1.3 Design objectives of IS 456:2000 The stated aim of design to IS 456:2000 is the achievement of an acceptable probability that structures being designed will perform satisfactorily during their intended life. With an appropriate degree of safety, they should sustain all the loads and deformations of normal construction and use and have adequate durability and adequate resistance to the effects of misuse and fire. 1.3.1 Limit state design IS 456:2000 Clause 18.2.1 states that Limit State Method of design shall normally be used but it also stresses the need for suitable materials, quality control, adequate detailing and good supervision. It states that where Limit State Method cannot be conveniently adopted then Working Stress Method may be used. Limit state method has been used in the generation of all tables and other design aids in this manual. 1.3.1.1 Loads & Forces All structures are to be designed for dead loads, imposed loads and wind loads, and for forces such as those caused by earthquake, and the effects due to shrinkage, creep, temperature etc where applicable. (IS 456:2000 19.1) Imposed loads, wind loads and snow loads shall be assumed in accordance with IS 875 Parts 2, 3 and 4 respectively. (IS 456:2000 19.3) Earthquake forces shall be calculated in accordance with IS 1893. (IS 456:2000 19.4)

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 8 The effects of shrinkage, creep and temperature need to be considered (refer IS 456:2000 Clause 19.5). In ordinary buildings such as low rise dwellings whose lateral dimensions do not exceed 45m the effects of temperature fluctuations as well as shrinkage and creep can be ignored (IS 456:2000 Clause 19.5.1) The combinations of loads shall be as given in IS 875 Part 5 (IS 456:2000 Clause 19.7) The symbols used for the various loads are: DL is the characteristic dead load EL is the characteristic earthquake load LL is the characteristic live load or imposed load WL is the characteristic wind load W is the characteristic total load 1.3.1.2 Partial safety factors (γ) The partial safety factors for load (γ f ) are given below for both the ultimate limit state and the serviceability limit state. These are used to account for possible unusual increases in load beyond the characteristic load, inaccurate assessment of the effects of loading, unforeseen stress redistribution, and variations in dimensional accuracy of the built structure. The design load in Limit State Design is to be the characteristic load multiplied by the appropriate partial safety factor γ f. (IS 456:2000 Clause 19.9) IS 456:2000 Clause 36.4.2.1 states that when assessing the strength of a structure or structural member for the limit state of collapse, the values of the partial safety factor, γ m, should be taken as 1.5 for concrete and 1.15 for steel. It is noted however that these values of γ m are already incorporated in the equations and the tables in IS 456:2000 for limit state design The design strength of a material or ancillary component is the characteristic strength divided by the appropriate partial safety factor for the material γ m. 1.3.1.3 Design loads for Limit State of Collapse The partial safety factors (γ f ) for each of the characteristic loads vary according to how the load is being combined in order to produce a more severe design load. Where alternative values are shown below, the value that produces a more severe design condition should be selected. (IS 456:2000 Table 18): a) Dead and imposed load i) design dead load γ f = 0.9 or 1.5 ii) design imposed load γ f = 1.5 b) Dead and wind load i) design dead load γ f = 0.9 or 1.5 ii) design wind load γ f = 1.5 c) Dead, imposed and wind load i) design dead load γ f = 1.2 ii) design imposed load γ f = 1.2 iii) design wind load γ f = 1.2

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 9 When designing for ultimate limit state, each of the above load combinations should be considered and that which produces the most severe conditions should be adopted. When considering earthquake effects EL can be substituted for WL in the above load combinations. When designing for loads from earth pressure it is recommended that a value of 1.5 be adopted for γ f 1.3.1.4 Design Loads for Limit State of Serviceability The partial safety factors (γ f ) for each of the characteristic loads vary according to how the load is being combined in order to produce a more severe design load. Where alternative values are shown below, the value that produces a more severe design condition should be selected. (IS 456:2000 Table 18): a) Dead and imposed load j) design dead load γ f = 1.0 ii) design imposed load γ f = 1.0 b) Dead and wind load j) design dead load γ f = 1.0 ii) design wind load γ f = 1.0 c) Dead, imposed and wind load i) design dead load γ f = 1.0 ii) design imposed load γ f = 0.8 iii) design wind load γ f = 0.8 Each of the above load combinations should be considered when assessing short term deflections, and the load combination that gives the most severe condition should be adopted. 1.3.2 Stability of the Structure 1.3.2.1 Overturning The stability of a structure as a whole against overturning shall be ensured. The restoring moment shall be not less than 1.2 times the maximum overturning moment due to the characteristic dead load plus 1.4 time the maximum overturning moment due to the characteristic imposed load. In cases where the dead load provides a restoring moment only 0.9 times the characteristic dead load shall be used. (IS 456:2000 20.1) 1.3.2.2 Sliding The structure must have a factor against sliding of 1.4 times the most adverse combination of the applied characteristic forces. Only 0.9 times the characteristic dead load shall be used when checking for sliding.

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 10 Structures built with mortarless masonry load bearing walls fully tied to floor slabs have far greater capacity to cope with accidental damage. Reinforced mortarless masonry walls with continuity of reinforcement through floor slabs or full anchorage of wall reinforcement into floor slabs act in unison with the slabs to compensate for the accidental removal or localised damage of load bearing elements. Slabs are capable of hanging from walls, and walls and slabs can behave as deep flanged wall beams to span greater distances and transfer loads to undamaged load bearing elements. 1.3.3 Structural properties 1.3.3.1 Characteristic compressive strength of mortarless masonry, f ck The adopted value for the compressive strength of the composite masonry unit and the core fill concrete is the characteristic cube compressive strength of the core fill concrete but not greater than 1.25 times the unconfined compressive strength of the masonry face shells. Note that the minimum cube strength of the core fill concrete (grout) is to be 5MPa greater than the unconfined compressive strength of the face shells of the blocks. IS 456:2000 clause 30.6 states that where hollow blocks are required to contribute to the strength of the member they shall be made of concrete or burnt clay and they shall have a crushing strength of at least 14MPa measured on the net section when axially loaded in the direction of the compressive stress in the slab. This clause is taken in itself to validate the use of part of the block shell in the calculation of the strength of a mortarless wall and furthermore to validate the use of IS 456:2000 to design mortarless walls. 1.3.3.2 Characteristic strength of reinforcing steel, f y The characteristic strength of the steel reinforcement shall be the yield stress of the bars. Generally Grade 500 hard grade deformed bars shall be used. 1.3.3.3 Elastic Moduli The elastic modulus of the core fill grout (E c ) is as follows: E c = 22,360 MPa for C20 Grout E c = 25,000 MPa for C25 Grout E c = 27,390 MPa for C30 Grout E c = 31,620 MPa for C40 Grout The elastic modulus of steel reinforcement E s = 200,000 MPa.