TEST REPORT. Report No.: F Rendered to: MI WINDOWS AND DOORS, LLC Gratz, Pennsylvania

Similar documents
TEST REPORT. Report No.: B Rendered to: MI WINDOWS AND DOORS, INC. Gratz, Pennsylvania

Architectural Testing TEST REPORT. Rendered to: COEUR D'ALENE WINDOW Spokane Valley, Washington. PRODUCT TYPE: PVC Fixed Window SERIES/MODEL: 3310

TEST REPORT. ASSOCIATED MATERIALS, INCORPORATED Cuyahoga Falls, Ohio. Rendered to: PRODUCT TYPE: Fixed Window SERIES/MODEL: A780 SPECIFICATIONS:

TEST REPORT. Rendered to: EARTHWISE GROUP, LLC Liberty Township, Ohio

Structural Performance Certification Authorization Report

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: A Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina

Structural Performance Certification Authorization Report

Structural Performance Certification Authorization Report

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

PERFORMANCE TEST REPORT. Report No.: H Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

Structural Performance Certification Authorization Report

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

INTERNATIONAL WINDOW TEST REPORT

Dennis Fassnacht Jr :59:35-04'00'

TEST REPORT. Report No.: A Rendered to: TUBELITE, INC. Walker, Michigan

AAMA 506 TEST REPORT. Report No.: G Rendered to: VEKA INC. Fombell, Pennsylvania

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: ALUMIL US. SERIES/MODEL: M300 Falcon PRODUCT TYPE: Aluminum Horizontal Sliding Window (XO)

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: MGM WINDOW COMPANY Hendersonville, Tennessee

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: BUILDERS ACCESSORIES, INC.

TEST REPORT. Report No.: F Rendered to: VELUX America LLC Greenwood, South Carolina

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: LEED HIMMEL INDUSTRIES, INC. Hamden, Connecticut

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY

TEST REPORT. Report No.: F Rendered to: FAIRFIELD METAL, LLC Fairfield, New Jersey

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: WASHOE EQUIPMENT, INC. DBA SUNOPTICS PRISMATIC SKYLIGHTS

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to:

TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC Marshall, Arkansas. Cycles 2,000,000. Summary of Results

ETC Laboratories Measuring Up To Your Standards And More

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America LLC. SERIES/MODEL: FCM B PRODUCT TYPE: Fixed Glass Glazed Curb Mount Skylight

Construction Consulting Laboratory, International

OSHA FALL PROTECTION TEST REPORT. Rendered to: SERIES/MODEL: FS S PRODUCT TYPE: Fixed Deck Mounted Skylight

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

TEST REPORT. Rendered to: ALL WEATHER INSULATED PANELS Vacaville, California. PRODUCT TYPE: Wall Panels SERIES/MODEL: DM45 Series

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

TEST REPORT. Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

TEST REPORT. Report No.: B Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

TEST REPORT. Report No.: F Rendered to: ALTECH PANEL SYSTEMS, LLC Cartersville, Georgia

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America Inc. SERIES/MODEL: VCM/VCE B PRODUCT TYPE: Venting Curb Mounted Skylight

TEST REPORT. Rendered to: All Weather Insulated Panels Vacaville, California. PRODUCT TYPE: Roofing Panels SERIES/MODEL: SR Series

TEST REPORT. Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

TEST REPORT. Rendered to: AD SKYLIGHTS, INC. Algonquin, Illinois. AD Skylight without Guard

G R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Vinyl

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

TEST REPORT ASTM E331. Report No.: E Rendered to: IMISON USA Houston, Texas

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: GAMCO CORPORATION. SERIES/MODEL: Curtain Wall TYPE: Glazed Wall Systems (Site-built)

AAMA 1801 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 185/3185 SP. TYPE: Picture Window

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Polyvinyl Chloride (PVC)

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 390. TYPE: Sliding Glass Door

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

AAMA 1801 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 420/430/440. TYPE: Sliding Glass Door

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: GAMCO CORPORATION. SERIES/MODEL: W250C Awning TYPE: Projecting (Awning)

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX AMERICA INC. SERIES/MODEL: CAP-1 PRODUCT TYPE: Fixed Acrylic Glazed Skylight

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: COASTAL INNOVATIVE PRODUCTS

PERFORMANCE TEST REPORT. Rendered to: ALL-WEATHER INSULATED PANELS. SERIES/MODEL: SM40 PRODUCT TYPE: Insulated Sandwich Wall Panel

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: C.R. LAURENCE CO., INC. SERIES/MODEL: S80 Monterey. TYPE: Bi-fold Door

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door with Impact Glass

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: BRICK-IT. SERIES/MODEL: Brick Veneer Panel Systems PRODUCT TYPE: Wall Panel Systems

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: CUSTOM VINYL PRODUCTS, LLC SERIES/MODEL: SHA4. TYPE: Single Hung Window

AAMA/WDMA/CSA 101/I.S.2/A440-08

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 6/8 Sliding Patio Door

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: GAMCO CORPORATION. Series/Model: CW250

AAMA/WDMA/CSA 101/I.S.2/A440-08

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 900 Series. TYPE: Out-swing Double Terrace Door

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

Intertek NAFS-11 Testing

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS & DOORS. SERIES/MODEL: Norwood 3070HI OOX PRODUCT TYPE: Sliding Glass Door

CR LAURENCE CO, INC. ACOUSTICAL PERFORMANCE TEST REPORT

PERFORMANCE TEST REPORT. Rendered to: HILTI CORPORATION. PRODUCT: Extreme Weather Window & Door Insulating Foam Sealant

CR LAURENCE CO, INC. ACOUSTICAL PERFORMANCE TEST REPORT

MOCK-UP TEST REPORT. Rendered to: TUBELITE INC. PROJECT: 300 ES Interior Glazed Curtain Wall

TEST REPORT. Report No.: H Rendered to: GEORGIA-PACIFIC WOOD PRODUCTS, LLC Atlanta, Georgia

STRUCTURAL PERFORMANCE TEST REPORT. Series Casement (Rep/Impact/AAMA) C-C70 940mm x 1930mm (37 x 76 )

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: CUSTOM VINYL PRODUCTS, LLC

H R2 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: CR LAURENCE CO., INC. Series/Model: 487-AR. Type: Office Partition

KNOTWOOD, A DIVISION OF OMNIMAX INTERNATIONAL MIAMI-DADE TEST REPORT

H R2 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: CR LAURENCE CO., INC. Series/Model: 487-AR. Type: Office Partition

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: GAMCO CORPORATION

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: TUBELITE, INC.

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: ALL SEASONS DOOR & WINDOW, MFG SERIES/MODEL: A500. TYPE: Double Hung Window

SECTION VINYL (PVC) WINDOWS

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: SPECIALTY WHOLESALE SUPPLY

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: MGM INDUSTRIES. SERIES/MODEL: 4600 Picture Window

TEST REPORT. Report No.: G Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

Transcription:

TEST REPORT Report No.: F7299.01-109-47 Rendered to: MI WINDOWS AND DOORS, LLC Gratz, Pennsylvania PRODUCT TYPE: Polyvinyl Chloride (PVC) Picture Window SERIES/MODEL: HM155 SPECIFICATION(S): AAMA/WDMA/CSA 101/I.S.2/A440-08, NAFS - North American Fenestration Standard/Specification for Windows, Doors, and Skylights Title Summary of Results AAMA/WDMA/CSA 101/I.S.2/A440-08 Class LC-PG50 1549 x 1676 (61 x 66)-FW Design Pressure ±2400 Pa (±50.13 psf) Air Infiltration 0.3 L/s/m 2 (0.06 cfm/ft 2 ) Water Penetration Resistance Test Pressure 360 Pa (7.52 psf) Test Completion Date: 04/12/16 Reference must be made to Report No. F7299.01-109-47, dated 06/03/16 for complete test specimen description and detailed test results. Reference Intertek-ATI Report No. F7297.01-109-47, dated 06/03/16 for complete Gateway test specimen description and test results. 130 Derry Court York, PA 17406 p. 717.764.7700 f. 717.764.4129

Page 1 of 7 1.0 Report Issued To: MI Windows and Doors, LLC 650 West Market Street P.O. Box 370 Gratz, Pennsylvania 17030-0370 2.0 Test Laboratory: Architectural Testing, Inc., an Intertek company ("Intertek-ATI") 130 Derry Court York, Pennsylvania 17406-8405 717-764-7700 3.0 Project Summary: 3.1 Product Type: Polyvinyl Chloride (PVC) Picture Window 3.2 Series/Model: HM155 3.2.1 This product also labeled under the following names: EC155, EC155MULL, HM155, HM155MULL, EC152, HM152, EC170, HM170, BB155, and BB170 3.3 Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). The specimen tested successfully met the performance requirements for a Class LC-PG50 1549 x 1676 (61 x 66)-FW rating. Reference Intertek-ATI Report No. F7297.01-109-47, dated 06/03/16 for complete Gateway test specimen description and test results. 3.4 Test Dates: 04/12/16 3.5 Test Record Retention End Date: All test records for this report will be retained until April 12, 2020. 3.6 Test Location: MI Windows and Doors test facility in Gratz, Pennsylvania. Calibration of test equipment was performed by Intertek-ATI in accordance with AAMA 205-01 "In-Plant Testing Guidelines for Manufacturers and Independent Laboratories". 3.7 Test Specimen Source: The test specimens were provided by the client. Representative samples of the test specimen(s) will be retained by Intertek-ATI for a minimum of four years from the test completion date. 3.8 Drawing Reference: The test specimen drawings have been reviewed by Intertek-ATI and are representative of the test specimen(s) reported herein. Test specimen construction was verified by Intertek-ATI per the drawings on file with Intertek-ATI. Any deviations are documented herein or on the drawings. 130 Derry Court York, PA 17406 p. 717.764.7700 f. 717.764.4129

Page 2 of 7 3.0 Project Summary: (Continued) 3.9 List of Official Observers: Name Richie Williard Joel Chronister Company MI Windows and Doors, LLC Intertek-ATI 4.0 Test Specification(s): AAMA/WDMA/CSA 101/I.S.2/A440-08, NAFS - North American Fenestration Standard/Specification for Windows, Doors, and Skylights 5.0 Test Specimen Description: 5.1 Product Sizes: Overall Area: Width Height 2.6 m² (28.0 ft 2 ) millimeters inches millimeters inches Overall size 1549 61 1676 66 5.2 Frame Construction: Frame Member Material Description Head, sill, and jambs PVC Extruded Track filler PVC Extruded, snap fit to the interior track of the head, sill, and jambs Joinery Type All corners Mitered Thermally welded Detail 5.3 Weatherstripping: No weatherstripping was utilized.

Page 3 of 7 5.0 Test Specimen Description: (Continued) 5.4 Glazing: No conclusions of any kind regarding the adequacy or inadequacy of the glass in any glazed test specimen(s) can be made. Glass Type 3/4" IG Spacer Type Metalreinforced butyl Interior Lite 1/8" tempered Exterior Lite 1/8" tempered Glazing Method Interior tape glazed with two-sided butyl tape, silicone in each corner, and secured with PVC snap-in glazing beads Daylight Opening Location Quantity Glass Bite millimeters inches Fixed daylight opening 1 1445 x 1572 56-7/8 x 61-7/8 1/2" 5.5 Drainage: Drainage Method Weephole with cover Weepslot Weepslot Weepslot Size Quantity Location 1-5/8" wide by 1/4" high 1/8" wide by 1/8" high 1-1/8" wide by 1/4" high 1" wide by 1/4" high Weepslot 1" triangle 2 5.6 Hardware: No hardware was utilized. 5.7 Reinforcement: No reinforcement was utilized. 2 2 2 2 3-1/2" from each end, through the exterior sill face 3-1/2" from each end, through the glazing track 5/8" from each end inside the hollow chamber in the sill 2-1/4" from each end through the interior snap-in cover 1" from each end of the internal snap-in cover

Page 4 of 7 6.0 Installation: The specimen was installed into a Spruce-Pine-Fir wood buck. The rough opening allowed for a 1/8" shim space. The exterior perimeter of the window was sealed with sealant. Location Anchor Description Anchor Location Head, sill, and jambs #6 x 1-5/8" drywall screws Located 3" from the corners and spaced 8" to 10" on center, through the mounting fin and into the wood buck

Page 5 of 7 7.0 Test Results: The temperature during testing was 19 C (67 F). The results are tabulated as follows: Title of Test Results Allowed Note Air Leakage, Infiltration per ASTM E 283 at 75 Pa (1.57 psf) 0.3 L/s/m 2 (0.06 cfm/ft 2 ) 1.5 L/s/m 2 (0.3 cfm/ft 2 ) max. 1, 6 Water Penetration, per ASTM E 547 N/A N/A 2 Uniform Load Deflection, per ASTM E 330 N/A N/A 2 Uniform Load Structural, per ASTM E 330 N/A N/A 2 Forced Entry Resistance, per ASTM F 588, Type: D - Grade: 10 Pass No entry Thermoplastic Corner Weld Pass Meets as stated Optional Performance Water Penetration, per ASTM E 547 360 Pa (7.52 psf) Pass No leakage 6 Uniform Load Deflection, per ASTM E 330 Deflections taken at sill +2400 Pa (+50.13 psf) -2400 Pa (-50.13 psf) Uniform Load Structural, per ASTM E 330 Permanent sets taken at sill +3600 Pa (+75.19 psf) -3600 Pa (-75.19 psf) 1.5 mm (0.06") 1.3 mm (0.05") Report only 3, 4, 5 <0.3 mm (<0.01") <0.3 mm (<0.01") 5.6 mm (0.22") max. 5.6 mm (0.22") max. 4, 5

Page 6 of 7 7.0 Test Results: (Continued) Note 1: The tested specimen meets (or exceeds) the performance levels specified in AAMA/WDMA/CSA 101/I.S.2/A440 for air leakage resistance. Note 2: The client opted to start at a pressure higher than the minimum required. Test results are reported under Optional Performance. Note 3: The deflections reported are not limited by AAMA/WDMA/CSA 101/I.S.2/A440 for this product designation. The deflection data is recorded in this report for special code compliance and information only. Note 4: Loads were held for 10 seconds. Note 5: Tape and film were used to seal against air leakage during structural testing. In our opinion, the tape and film did not influence the results of the test. Note 6: Reference Intertek-ATI Report No. F7297.01-109-47, dated 06/03/16 for complete Gateway test specimen description and test results.

Page 7 of 7 Intertek-ATI will service this report for the entire test record retention period. Test records such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation, will be retained by Intertek-ATI for the entire test record retention period. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Intertek-ATI. For ARCHITECTURAL TESTING, INC. Joel Chronister Technician Timothy J. McGill Manager - Product Testing JC:asm/cmd Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: Alteration Addendum (1) Appendix-B: Location of Air Seal (1) Appendix-C: Complete drawings packet on file with Intertek-ATI. This report produced from controlled document template ATI 00438, revised 06/27/14.

Appendix A Alteration Addendum Note: No alterations were required.

Appendix B Location of Air Seal: The air seal between the test specimen and the test wall is detailed below. The seal is made of foam weatherstripping and is attached to the edge of the test specimen buck. The test specimen buck is placed against the test wall and clamped in place, compressing the weatherstripping and creating a seal.

Appendix C Drawing(s) Note: Complete drawings packet on file with Intertek-ATI.