Lamit Industries Nailbase Panels General Recommendations

Similar documents
Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

SECTION STRUCTURAL INSULATED PANELS

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

MASTERFORMAT SPECIFICATION

May 2013 CONSTRUCTION MANUAL

RAY-CORE Structural Insulated Roof and Wall Panels

SPECIFICATION GUIDELINE

AFM Corporations Juniper Path, Suite 260 Lakeville, MN 55044

SECTION CEMENTITIOUS ROOF DECK (CEMENTITIOUS WOOD FIBER PLANK)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

The better way to build TM. Installation Manual NAILBASE PANELS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

DESIGN. Detailed planning and designing information on Premier Structural Insulated Panels (SIPs) Stronger. Straighter. Greener.

Dricon FRT Wood Specification

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SPECIFICATION GUIDELINE

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Magnum Board Section Digicon Information Inc. Page 1

RECOMMENDED DESIGN SPECIFICATION

SSL-175. Specifications

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

(Project Location) (your firm's name)

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

SECTION METAL ROOF & WALL PANELS

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

INSPECTION GUIDELINES: STRUCTURAL INSULATED PANELS (SIPs)

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

DL-200. Specifications

SECTION PRE-ENGINEERED BUILDING INSULATION

Code Compliance Research Report CCRR-0231

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

ACFoam -III Specifications Atlas Roofing

SECTION AWNINGS

Attachment A Project Specification Repair of a Salt Dome Building Philadelphia County, Betsy Ross Stockpile # Dome# Project #

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

SECTION COMPOSITE DECKING. Display hidden notes to specifier. (Don't know how? Click Here)

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Note to Specifier: Use this product for coated glass-mat faced polyisocyanurate insulation boards such as Rboard.

A. Meet at Project site <insert number> days before starting installation.

ENVIROBEAM SECTION ENVIRO-ROOF CURBS

SECTION COMPOSITE TRIM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

OptiLiner Banded Liner System, Thermal, Metal Building

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

ACFoam-II HCFC Free "Green" Polyiso Specification

Firestone Polyiso Boards

Residential Warranty. Thank you!

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

SILVER LINE BUILDING PRODUCTS

Melton Classics, Inc. Architectural Urethane TM SIMULATED WOOD TRIM SECTION 06455

Magnum Board Section Digicon Information Inc. Page 1

A. Section Wood, Plastics and Composites.

Listing Report: MUR Reissue Date: 12/07/17 This report is subject to annual review

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

ACFoam CrossVent RB Specifications Atlas Roofing

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

SECTION FOAMED-IN-PLACE INSULATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Code Compliance Research Report CCRR 0241

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

ACFoam Supreme Specifications Atlas Roofing

SECTION SPRAY FOAM INSULATION

NatureWood Construction Product Specification Guide

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Structural Insulated Panels (SIPs) Commercial, Industrial and Residential Applications

SECTION Fiber Reinforced Stucco 1

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

WorthingtonUrethane Millwork Architectural Guide Specifications

INSTALLATION GUIDE nailable rigid insulation substrate for roofing applications

Prepared for: Thompson Architectural Metals Company, Inc E. Hillsborough Avenue Tampa, FL 33605

SECTION THERMAL INSULATION

Architectural Wall Products Guide Specifications

Code Compliance Research Report CCRR-0164

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

NRM-7000 Guide Specifications

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

SECTION CORK-FACED ACOUSTICAL WALL PANELS. A. Class A cork-faced acoustical wall panels manufactured from recycled wood fiber material.

SECTION COMPOSITE CLADDING. Display hidden notes to specifier. (Don't know how? Click Here)

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

TECH BULLETIN. SIP No. Subject: Engineered Wood Lap Siding from Louisiana-Pacific. Date: August 2010 (Revised January 2015)

Eclipse OSB Radiant Barrier OSB Structural Panels from RoyOMartin

A. Thermal Conductivity: Thicknesses indicated are for thermal conductivity (k-value at 75 degrees F) specified for each material.

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

Sept 30, 2004 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

A. Supplier Qualifications: The ACRYSHIELD SPF Roofing System, as supplied by National Coatings Corporation, is approved for use on the project.

COMMERCIAL BUILDING APPLICATIONS

Transcription:

Lamit Industries Nailbase Panels General Recommendations Lamit Industries Nailbase Panels Sizes Lamit Industries Nailbase Panels are made in a variety of sizes; most commonly 4 x 8. Consult Lamit Industries for sizes, thickness, and fabrication services available in your area. Environmentally Safe Lamit Industries Nailbase Panels are compiled with EPS as the core material. This EPS contains no CFCs, HCFCs, HFCs or formaldehyde and it is recyclable. EPS is inert, non-nutritive and highly stable to support recycling and energy conservation is always recommended. Warranty Lamit Industries Nailbase Panels provides a 20 year warranty covering thermal performance. Contact Lamit Industries for details regarding the warranty guidelines. Handling & Storage Protection Lamit Industries Nailbase Panels should be stored in a fully supported manner and protected from the weather. Cover stored panels with tarps or similar protective wraps. Exposure 1 OSB facings are used in Lamit Industries Nailbase Panels; however, panels used for roof systems must have temporary roofing applied at the time of installation. Apply finished roofing when immediately practical. Sealant and Splines Lamit Industries Nailbase Panels are joined using splines. These attachments are made with nails, staples, or screws and sealant. The sealant provided by Lamit Industries is safe for expanded polystyrene foam insulation. Apply the sealant in a continuous 3/8 bead as shown in Lamit Industries Nailbase details. This size bead will result in the optimum coating when the plates and splines are installed.

Vapor Retarders Lamit Industries Nailbase Panels may require the use of a vapor retarder to ensure long term durable roof structures. Consult with design professionals for a recommendation. Special Treatments Lamit Industries Nailbase Panels are produced with Borate that protects the core insulation from potential termite damage. Disclaimer Lamit Industries Nailbase Panel details, illustrations, pictures and guidelines provided herein give basic information and illustrate examples of Lamit Industries Nailbase Panel installation. The basic information provided herein is not intended to cover every potential use and/or application of Lamit Industries Nailbase Panels. It is the responsibility of the installer to become familiar with their specific application and determine if Lamit Industries Nailbase Panels are suitable. By commencing work, the installer accepts full responsibility for the proper and safe installation of Lamit Industries Nailbase Panels at his jobsite. Adding an insulation component may change the behavior of a roof assembly with regard to air movement, water vapor transmittance, bulk water management and heating, cooling and ventilation systems. It is the responsibility of the owner or the owner s representative to design the insulated wall assembly to perform in a manner ensuring function and durability. Furthermore, it is the sole responsibility of the installer to meet all federal and local regulatory requirements for job site safety for themselves, workers and any others on the job site while in the execution of all phases of Lamit Industries Nailbase Panel installation.

Technical Bulletin Bulletin #1005 04/19/2012 Lamit NailBase Panel-Fastening Requirement for Sloped Roofs Fasteners must have 1 minimum penetration into structural deck For projects with wind speeds in excess of 110 mph, consult a professional engineer for fastening requirements. P.O. Box 07750, 710 Marion Rd. Columbus, Oh 43207 Phone (614)444-3010 Fax (614)444-4264

Technical Bulletin Bulletin #1005 04/19/2012 Lamit NailBase Panel-Fastening Patterns for 4 x8 NailBase Panels P.O. Box 07750, 710 Marion Rd. Columbus, Oh 43207 Phone (614)444-3010 Fax (614)444-4264

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio 43207 P-(614)444-3010 F-(614)444-4264 info@lamitindustries.com WWW.LAMITINDUSTRIES.COM SECTION 07 22 16 NAILBASE INSULATION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Nailbase Insulation. B. Related Sections: Section(s) related to this section include: 1. Section 06 10 00 Rough Carpentry 1.02 SYSTEM DESCRIPTION Nailbase Insulation consisting of oriented strand board (OSB) laminated to an expanded polystyrene (EPS) insulation core. 1.03 REFERENCES A. ASTM C578 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation. B. PS2 - Performance Standard for Wood-based Structural-use Panels. C. ICC ES AC12 Acceptance Criteria for Foam Plastic Insulation. 1.04 SUBMITTALS A. Product Data: Submit product data for specified products. 1. EPS Code Compliance: Provide ICC ES code report for EPS foam with evidence of compliance with code. Code report shall include compliance with ICC ES AC12 (Foam Plastic) and dated July 2009. 2. Manufacturer s Instructions: Nailbase Insulation manufacturer s installation guidelines. B. Quality Assurance Submittals: Submit the following: 1. Certificate: certificate showing compliance of EPS insulation to Third Party Quality Control program of Underwriters Laboratories, Inc. C. Warranty: Warranty documents specified herein. 1.05 QUALITY ASSURANCE A. Source Limitations: Obtain all Nailbase Insulation through one source. All accessories to be as furnished or recommended by the Nailbase Insulation manufacturer. 1.06 DELIVERY, STORAGE & HANDLING A. Delivery: Deliver materials from Nailbase Insulation manufacturer with identification labels or markings intact. B. Storage: Store products off the ground, in dry conditions, under cover until ready for installation. Protect insulation from open flame and keep dry at all times. PART 2 PRODUCTS 2.01 Manufacturers/Suppliers: A. Lamit Industries, Inc. 710 Marion Rd., Columbus, OH 43207 www.lamitindustries.com Phone 614-444-3010 07/12/2010

2.02 Materials A. Nailbase Insulation consisting of the following: 1. UL certified EPS core complying with ASTM C578 Type I insulation. Insulation manufacturer shall provide Third Party UL certificate. 2. OSB identified with APA or PFS performance mark with Exposure I durability rating and performance in accordance with DOC PS-2 span rating 24/16 or greater. 2.03 Accessories A. Fasteners: corrosion resistant SIP screws compatible with the Nailbase Insulation shall be provided by the Nailbase Insulation manufacturer. 1. Wood Screws for attachment to wood members 2. Heavy Duty Metal Screws for attachment to metal members (16 gauge to 3/16 ) 3. Light Duty Metal Screws for attachment to metal decks (18 gauge or thinner) B. Splines: As required, OSB splines shall be supplied by the Nailbase Insulation manufacturer. C. Sealant: As required, Sealant shall be specifically designed for use with Nailbase Insulation. Sealant shall be provided by the Nailbase Insulation manufacturer. D. Dimensional Lumber: SPF, #2 or better, or engineered equivalent unless otherwise required by architectural drawings. 2.04 Insulation Size A. Sizes: Nailbase Insulation shall be manufactured to sizes in accordance with the approved architectural drawings B. Thermal Resistance, R-value 1. 4 thick (Nom.) Nailbase Insulation with R-value of 15 at 75 o F (16 at 40 o F) 2. 6 thick (Nom.) Nailbase Insulation with R-value of 23 at 75 o F (24 at 40 o F) 3. 8 thick (Nom.) Nailbase Insulation with R-value of 30 at 75 o F (32 at 40 o F) 4. 10 thick (Nom.) Nailbase Insulation with R-value of 38 at 75 o F (40 at 40 o F) 5. 12 thick (Nom.) Nailbase Insulation with R-value of 46 at 75 o F (48 at 40 o F) 2.05 PRODUCT SUBSTITUTIONS A. Substitutions: No substitutions permitted without thirty day (30) prior approval. 2.06 SOURCE QUALITY A. Source Quality Assurance: All components (excluding dimensional lumber) required shall be supplied by Nailbase Insulation manufacturer or its approved supplier. 1. Provide evidence of UL Third Party inspection and labeling of all EPS insulation used in manufacture of Nailbase Insulation. 2. Nailbase Insulation manufacturer shall provide 20 year 100% R-Value warranty. B. Source Quality: Obtain Nailbase Insulation from a single manufacturer. PART 3 EXECUTION 3.01 MANUFACTURER S INSTRUCTIONS A. Compliance: Install in accordance with manufacturer's instructions. B. Deviations from standard detail and design values shall be approved by the architect/engineer for the project. 3.02 EXAMINATION 1. Site Verification of Conditions: Verify substrate conditions (which have been previously installed under other sections) are acceptable for product installation in accordance with manufacturer s instructions. 07/12/2010

3.03 INSTALLATION A. Nailbase Insulation Installation: 1. Fastening: Attach Nailbase Insulation with OSB facing up, to structural deck/substrate, using SIP screws as shown on drawings. SIP screw to have a minimum of 1" (25.4 mm) penetration into structural deck/substrate. 2. Vapor Retarders: Provide vapor retarders as mandated by building code or engineering analysis. 3.04 PROTECTION A. Protection: Protect installed product and finish surfaces from damage during construction. 1. Protect Nailbase Insulation from weather by installing roofing materials to provide temporary protection at the end of the day or when rain or snow is imminent. 2. Install weather resistant roofing and/or cladding materials per roofing and/or cladding manufacturers specifications and recommendations. 3. Nailbase Insulation shall be protected from exposure to solvents and their vapors. END OF SECTION 07/12/2010