CIRCUPOSIT 71 Full Build Electroless Copper Nitrate Bath (Generic Concentrates) For Electronic Finishing Applications

Similar documents
Use vigorous air agitation while adding the components in the order shown: 2.7% by volume CIRCUPOSIT LC-9100C Electroless Copper

CIRCUPOSIT Neutralizer 3313 For PWB Metallization Applications

CIRCUPOSIT Electroless Copper (USING CUPOSIT Z AND Y-1) For PWB Metallization Applications

PREPOSIT Etch 748. For PWB Metallization Applications. For use in the CIRCUPOSIT 3000 Process. Bath Make-up Metric (for 100 liters)

SILVERON TM GT-101 Bright Silver Cyanide-Free Bright Electrolytic Silver For Electronic, Decorative and Industrial Finishing Applications

COPPER GLEAM RG 11 Acid Copper Plating Process

SOLDERON SC Process. For Electronic Finishing Applications. Deposits meet or exceed Military Specification Method 202F, Method 208F.

AURALL 305M Electrolytic Gold For Electronic Finishing Applications

NIPOSIT PM-980 W Semi-Bright Electroless Nickel Process For Industrial Finishing Applications

PALLADURE 200 Pure Palladium Process

SILVER GLO 3KBP. With SILVER GLO 33BP Silver Plating Process For Electronic Finishing Applications. Silver M etal as Silver: Cyanide (80.

TINGLO CULMO Bright Acid Tin Electroplating (with Starter/Brightener 2.5X) For Electronic Finishing Applications

PALLAMET 500 Palladium-Nickel

SILVER GLO 3K Silver Process

4831 S. Whipple Avenue Chicago IL Phone: Fax:

PALLAMERSE SMT 2000 For PWB Metallization Applications

NICKEL GLEAM BR 220 BRIGHT NICKEL PROCESS

SOLDERON MHS-W MATTE TIN AND TIN-LEAD PROCESS

SOLDERON ST-200 For Electronic Finishing Applications

RONOVEL C AUROSPEED CVD

CHROME GLEAM 3C Jet Black Trivalent Chromium Plating Process

ELECTROPOSIT 1100 B-2 Acid Copper Additive

PRETREATMENT TECHNICAL DATA SHEET A REGENERABLE ACID PICKLE PRODUCT DESCRIPTION

PARALOID EXL-5900 Optical Properties Modifier For Polycarbonate and Polystyrene

SOLDERON BLS For Electronic Finishing Applications

TINPOSIT LT-26 IMMERSION TIN For PWB Metallization Applications

PARALOID EXL 2314 Impact Modifier

PARALOID EXL-2690 IMPACT MODIFIER

PARALOID EXL-2620 (Powder) MBS Impact Modifier For Polycarbonate, Polyesters and their Blends

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

PARALOID EXL-2655 Impact Modifier For Thermoset Applications

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate

AVANSE ST-410 Acrylic Emulsion

ROPAQUE OP-96 All-Purpose Pigment Engineered to Improve Waterborne Coatings

Manufactured for North America exclusively by Automated Chemical Solutions, Inc E. Roeser Road Phoenix, Arizona 85040

Technical Data Sheet. Physical Specifications

Technical Data Sheet

Lumina. Bright, leveled deposits in less time Excellent ductility Good chromium reception Very low additive consumption rate. Nickel Plating System

PavCoTing. Chromium appearance and corrosion resistance Ease of plating bath control Wide current density range

RHOPLEX EP-6060 Acrylic Polymer For Factory-Applied Wood Coatings

HyProTec. Hexavalent free RoHS, ELV and WEEE compliant. HyPro System

TECHNICAL BULLETIN IMMERSION SILVER - IS150

ELECTROPOSIT 1100 Acid Copper

NiClipse C. Ammonium chloride free

Luster-On Products. Technical Data Sheet LUSTER-ON CADMIUM SPECIAL

ROPAQUE Ultra E Opaque Polymer

INTERVIA BPP-10 Photoresist

Laser EX 50 Product Code: Revised Date: 03/17/2009. Laser EX 50

SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

HOUGHTO-PHOS 6300 LOW TEMPERATURE MANGANESE PHOSPHATE

HAVALLOY Z-C ACID CHLORIDE ZINC / COBALT PROCESS

E-Chrome Ultra Yellow 600

4831 S. Whipple Avenue Chicago IL Phone: Fax:

ACUMER 9400 High-Performance Dispersant for Various Minerals

NiClipse. Zinc Alloy Plating NiClipse

SurTec 609 EC Pre-Treatment prior to E-Coat

DURNI-COAT DNC

RHOPLEX SG-10M 100% Acrylic Emulsion For Interior/Exterior Semigloss Latex Paints

Alkzinc 818. Mirror bright finish Good zinc deposit distribution Very good adhesion and ductility Excellent chromate receptivity

Technical Data Sheet. Physical Specifications. ph 6-7. Storage Requirements

COLORMAX 9000C: Stannous Based Electrolytic Colouring Process

Technical Process Bulletin

PARALOID AU-1033 Acrylic Polyol with Low Isocyanate Demand For Coatings on Recreational Equipment and Fleet Refinishing

FASTRACK HD-21A Polymer Emulsion for Durable Waterborne Traffic Marking Paints

Brass Plating Process

OPTIDOSE 4210 Traceable Polymeric Acid Scale Inhibitor and Dispersant

ACUMER 9300 Dispersant Polymer for Mineral Slurries

High Throw Bright Acid Copper for Rack and Barrel Plating

Standard Methods for the Examination of Water and Wastewater

Black-Magic RT S 30 Product Code: Revised Date: 01/11/2013. Black-Magic RT S 30

SurTec 650 chromital TCP

Ultrex CAA Product Code: Revised Date: 10/09/2006. Ultrex CAA Heavy Duty Alkaline Product Derusting - Descaling - Activation

PARALOID AU-608 TBZ Acrylic Polyol For Auto Refinishing, GIF and Conventional Spray Applications, and Airless Spray Maintenance

SurTec 717 R Alkaline Zinc/Nickel Process

Technical Process Bulletin

UV5 POSITIVE DUV PHOTORESIST For Microlithography Applications

Technical Process Bulletin

Ziniloy Zinc Alloy Plating

Ultrex EDM Product Code: Revised Date: 07/26/2006. Ultrex EDM Heavy Duty Alkaline Product Derusting - Descaling - Activation

IRON (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 600 C

Plating Systems Hex - A - Gone

PARALOID TMS-2670 MBS Impact Modifier For Epoxy Resin Applications

OPTIDOSE 1000 Traceable Polymer A Tool for Maintaining Maximum Heat Transfer

SurTec 704 Cyanide-Free Alkaline Bright Zinc Process of the New Generation

Laser ACB 50 Product Code: Revised Date: 03/17/2009. Laser ACB 50

BONDERITE 1070F CLEANER/COATER PROCESS FOR MULTIMETALS

NOTE: BONDERITE C-AK 4338C AERO should not be used on reactive alloys such as aluminum.

Technical Process Bulletin

ACUMER 2200 High Performance Scale Inhibitor

SurTec 704 Cyanide-Free Alkaline Bright Zinc Process of the New Generation

Technical Process Bulletin

METHOD #: Approved for NPDES (Issued 1971) Oxygen, Dissolved (Modified Winkler, Full-Bottle Technique) ANALYTE: CAS # O Oxygen

Hex-A-Gone. Hexavalent chromium-free Less energy consumption compared to hexavalent chromium solutions. Plating System

Plating System. Hexavalent Chromium-free Reduced energy consumption

Lead-free electroless plating nickel bath for high wear and corrosion resistant applications

Zinc Alloy Plating Ziniloy

PRIMAL SF-208ER Binder

TECHNICAL DATA SHEET CUPROBRITE Revolutionary & New generation Bright Acid Copper Plating Process

NITEC CRYSTAL 1. Elektrolyt to achieve uniform and non reflective Nickel deposits

Transcription:

CIRCUPOSIT 71 Full Build Electroless Copper Nitrate Bath (Generic Concentrates) For Electronic Finishing Applications Regional Product Availability Description N. American Asia CIRCUPOSIT 71 Full Build Electroless Copper represents a major advance in full-build electroless copper. Smooth electroless copper deposits, 25 µm (1,000 µin) or greater in thickness, can be produced. CIRCUPOSIT 71 yields deposits that are smooth, bright and uniform in color. Advantages Ductile deposits Uniform, smooth, bright-pink deposit Excellent solution stability Easy to monitor and control Offers reproducible results Bath Make-Up Chemicals Required Metric (U.S.) Deionized (D.I.) water 763 ml/l (76.3% v/v) CIRCUPOSIT 71 E 170 ml/l (17% v/v) CIRCUPOSIT 71 A 15 ml/l (1.5% v/v) CIRCUPOSIT 71 U 10 ml/l (1.0% v/v) CIRCUPOSIT 71 T 20 ml/l (2.0% v/v) CUPOSIT Z 10 ml/l (1.0% v/v) CUPOSIT Y 10 ml/l (1.0% v/v) CIRCUPOSIT 71 S 2 ml/l (0.2% v/v) Make-Up Procedure 1. Add D.I. water to a clean tank and mix thoroughly. 2. Add CIRCUPOSIT 71 E Electroless Copper to tank and mix thoroughly. 3. Add CIRCUPOSIT 71 A to tank and mix thoroughly. 4. Add CIRCUPOSIT 71 U to tank and mix thoroughly. 5. Add CIRCUPOSIT 71 T to tank and mix thoroughly. 6. Add CUPOSIT TM Z Additive to tank and mix thoroughly. 7. Add CUPOSIT Y to tank and mix thoroughly. 8. Add CIRCUPOSIT 71 S to tank and mix thoroughly. 9. Dilute to final volume with D.I. water. 10. Heat solution to operating temperature. 11. Analyze the bath for copper, formaldehyde, sodium hydroxide and EDTA following the procedures in the Bath Maintenance section and adjust as necessary. 12. Dummy plate for at least 5 hours at approximately 0.5 dm 2 /L (0.2 ft 2 /gal.) until the hourly rate is 2 3 µm/hour (80 120 µin/hour). Page 1 of 12

Bath Operation Metric Parameter Range Recommended Copper Metal 2.8 3.3 g/l 3.05 g/l Sodium Hydroxide Conc. 2.5 4.0 g/l * g/l HCHO 1.5 3.0 g/l * g/l EDTA 4Na 41 45 g/l 43 g/l CIRCUPOSIT 71 U 70 130% 100% Electroless Copper CIRCUPOSIT 71 S 50 100% 75% CIRCUPOSIT 71 T 100 120% 110% ph 11.8 12.2 12.0 Temperature 68 72 C 70 C Specific Gravity Below 1.09 Loading Factor 0.6 1.2 dm 2 /L Deposition Rate 0.033 0.050 microns/minute Agitation Aeration is mandatory at all times; air flow rate is 0.3 0.5 liters of air per liter of bath per minute during plating and 0.1 0.3 liters of air for storage at ambient temperature Bath Operation U.S. Parameter Range Recommended Copper Metal 0.37 0.44 oz./gal. 0.41 oz./gal. Sodium Hydroxide Conc. 0.33 0.53 oz./gal. * oz./gal. HCHO 0.2 0.4 oz./gal. * oz./gal. EDTA 4Na 5.47 6.00 oz./gal. 5.73 oz./gal. CIRCUPOSIT 71 U Electroless Copper 70 130% 100% CIRCUPOSIT 71 S 50 100% 75% CIRCUPOSIT 71 T 100 120% 110% ph 11.8 12.2 12.0 Temperature 155 162 F 158 F Specific Gravity Below 1.09 Loading Factor 0.25 0.50 ft 2 /gal. Deposition Rate 80 120 microinches/hour Agitation Aeration is mandatory at all times; air flow rate is 0.3 05 gal. of air per liter of bath per minute during plating and 0.03 0.08 gal. of air for storage at ambient temperature * NaOH Optimum and Deposition Rate: The deposition rate is the primary factor for assuring deposit quality and should be controlled, depending on the type of application, at a level between 0.033 0.050 microns per minute (80 and 120 microinches per hour) with minimum fluctuation. The deposition rate is controlled by hourly analysis for total alkalinity (as NaOH) to hold ph constant and adjustment of the CUPOSIT Y Replenisher pump flow rate. Contact your Dow Electronic Materials Representative for details on rate determination and replenishment adjustment. Page 2 of 12

Bath Maintenance Copper Metal Copper Metal Control Procedure The Dow Electronic Materials Process Controller has been developed to automatically and precisely control solutions such as the CIRCUPOSIT 71 Full Build Electroless Copper bath to offer instantaneous, real time deposition rate and thickness measurements. The use of one of these is recommended. Contact your Dow Electronic Materials Representative for details. Maintain copper metal concentration between 2.8 3.3 g/l (0.37 0.44 oz./gal.). To raise the copper content by 0.1 g/l (0.013 oz./gal.), add 0.50 ml/l CIRCUPOSIT 71 A Additive (0.050% v/v). Copper metal concentration can be determined following the control procedure below. I. Equipment a) 20 ml class A volumetric pipette b) 250 ml Erlenmeyer flask c) Two-50 ml graduated cylinders d) 50 ml burette e) Scale f) Hot plate II. Reagents a) Sulfuric acid, 20% b) Sulfamic acid, crystals, reagent A.C.S. c) Potassium iodide, crystals, reagent A.C.S. d) Potassium thiocyanate, 10% e) Starch indicator solution, 1% III. Titrant Sodium thiosulfate, 0.1N standardized IV. Procedure a) Pipette 10 ml of CIRCUPOSIT 71 Electroless Copper bath into a 250 ml Erlenmeyer flask. b) With gentle stirring, add 50 ml D.I. water, 40 ml sulfuric acid (20%), and approximately 0.5g sulfamic acid. c) Stir and heat sample to a boil. Boil sample for approximately one minute. d) Allow sample to cool for 5 minutes. e) Add approximately 2g potassium iodide and swirl. f) Titrate with 0.1N sodium thiosulfate to a light straw color. g) Add 20 ml potassium thiocyanate (10%), 5 ml starch indicator and mix. h) Continue the titration to an off white endpoint. i) Record ml titrant. V. Calculation copper metal g/l = ml titrant x 0.6354 copper metal oz./gal. = ml titrant x 0.08472 % copper = copper metal g/l x 32.8 Page 3 of 12

Sodium Hydroxide And Formaldehyde Sodium Hydroxide And Formaldehyde Control Procedure Sodium hydroxide should be maintained using CUPOSIT TM Z Additive. Formaldehyde should be maintained using CUPOSIT Y. To raise sodium hydroxide content by 1 g/l (0.13 oz./gal.), add 2.9 ml/l of CUPOSIT Z (0.29% v/v). To raise formaldehyde content by 1 g/l, add 4.0 ml/l of Cuposit Y (0.4% v/v). Sodium hydroxide and formaldehyde concentrations can be determined following the control procedure below. I. Equipment a) 5 ml class A volumetric pipette b) 250 ml beaker c) 50 ml burette d) ph meter II. Reagents a) Sodium sulfite, crystals, reagent A.C.S. b) ph 10 buffer solution III. Titrant Hydrochloric acid, 0.1N standardized IV. Procedure a) Check the ph of the sodium sulfite solution to ensure that it is between 9.5 and 10.2. Prepare a fresh sodium sulfite solution if the ph is outside this range. b) Pipette 20 ml sample into a 250 ml beaker. c) Using a ph meter, standardize solution to ph 10.0 with buffer solution. d) Titrate to ph 10.20 with 0.1N hydrochloric acid. e) Record ml titrant for the sodium hydroxide calculation (V1). f) Adjust the ph to 10.00 with 0.1N hydrochloric acid and add approximately 1g sodium sulfite crystals. g) Stir the sample for 1 2 minutes. h) Refill the burette with 0.1N hydrochloric acid and titrate the sample to ph of 10.00 (V2). i) Record ml titrant for the formaldehyde calculation. V. Calculation Total Alkalinity g/l = V1 x 0.20 Total Alkalinity oz./gal. = V1 x 0.027 Free Formaldehyde g/l = V2 x 0.15 Free Formaldehyde oz./gal. = V2 x 0.02 EDTA EDTA Control Procedure: EDTA concentration should be maintained between 41 45 g/l (5.47 6.0 oz./gal.). To raise the EDTA concentration by 1 g/l, add 3.8 ml/l CIRCUPOSIT 71 E Electroless Copper (0.38% v/v). EDTA concentration can be determined following the control procedure below. I. Equipment a) 10 ml class A volumetric pipette b) 100 ml volumetric flask c) 50 ml graduated cylinder d) 50 ml burette II. Reagents a) Copper Sulfate; dissolve 10g of copper sulfate 5H 2 O, 136g of sodium acetate 3H 2 O and 32 ml of acetic acid in water; dilute to one liter and mix Page 4 of 12

III. IV. b) Sodium Thiosulfate Anhydrous; dissolve 70g of sodium thiosulfate anhydrous in water; dilute to one liter and mix Procedure a) Pipette 5 ml of CIRCUPOSIT 71 Electroless Copper into a 100 ml volumetric flask. b) Add 10 ml of the copper sulfate solution. c) Add 10 ml of the sodium thiosulfate solution and shake. d) Dilute to exactly 100 ml with D.I. water. e) Measure absorbance, ABS (730 nm; D.I. Water reference). f) Obtain the concentration from the calibration curve. Calculation Formula for linear portion of Dow Electronic Materials calibration curve from 25 to 45 g/l. EDTA g/l = 75.5 (ABS) - 0.78 V. Calibration Curve 0.7 Absorbance vs. EDTA 4Na Content 0.6 0.5 ABS 0.4 0.3 0.2 0.1 0.0 0 10 20 30 40 50 60 EDTA (g/l) CIRCUPOSIT TM 71 U Electroless Copper CIRCUPOSIT TM 71 U Electroless Copper Control Procedure The CIRCUPOSIT 71 U Electroless Copper concentration should be between 70 130%. To raise the U content by 10%, add 1.0 ml/l of CIRCUPOSIT 71 U. CIRCUPOSIT 71 U concentration can be determined following the control procedure below. I. Equipment a) 200 ml beaker b) 100 ml graduated cylinder c) Two-250 ml separatory funnels d) 100 ml beaker e) Hot plate f) UV spectrophotometer II. Reagents a) Tri-sodium phosphate 12H 2O powder b) Sodium hydroxide, 1N c) Sulfuric acid, 1N d) Trichloroethylene e) Fe No. 1 solution; dissolve 3g of Mohr s salt (ferrous ammonium sulfate 6H 2 O), 10g of L- ascorbic acid, 40g of sodium chloride and 86 ml of acetic acid (99.5%) in water; dilute to one liter and mix f) Fe No. 2 solution; dissolve 40g of sodium acetate anhydrous in water; dilute to one liter and mix Note: Store reagents (e) and (f) in the refrigerator and use within one month. Page 5 of 12

III. Procedure a) Accurately measure a 100 ml sample of CIRCUPOSIT TM 71 Electroless Copper bath into a 200 ml beaker. b) Add 5g of Tri-sodium phosphate 12H 2 O powder and dissolve. c) After the powder has dissolved, confirm the ph at 12.0 12.5. (Adjust with 1N NaOH or 1N H 2 SO 4 if necessary.) d) Decant into a 250 ml separatory funnel. e) Add approximately 50 ml of trichloroethylene. f) Shake for at least 5 minutes and allow to stand for at least 10 minutes. g) Decant only the trichloroethylene layer that contains the U component (bottom layer) into another 250 ml separatory funnel. h) Place 20 ml of Fe No. 1 solution (e) and 20 ml of Fe No. 2 solution (f) into a 100 ml beaker. Heat to 65 75 C (149 167 F) and add while hot to the above trichloroethylene solution. i) Immediately shake three times to let the vapor out. Color of the solution turns pink. j) Shake for at least 10 minutes and allow to stand for at least 15 minutes. k) Separate and dispose of the bottom trichloroethylene layer. l) Decant the red upper layer into a 200 ml beaker. m) Heat to approximately 60 C (140 F) with occasional stirring. n) As the slightly cloudy whitened-red solution becomes clear, decant into a 50 ml volumetric flask. o) After cooling to room temperature, dilute with D.I. water to 50 ml. p) Measure absorbance, ABS (520 nm; D.I. water reference). q) Obtain the concentration from the calibration curve. IV. Calculation Formula for linear portion of Dow Electronic Materials calibration curve from 50 to 150%. CIRCUPOSIT 71 U % = 4.40 + 187(ABS) - 113 (ABS) 2 + 38.7(ABS) 3 V. Calibration Curve 2.0 Absorbance vs. U Content % 1.8 1.6 1.4 1.2 ABS 1.0 0.8 0.6 0.4 0.2 0.0 0 20 40 60 80 100 120 140 160 180 200 Ingredient U Content (%) CIRCUPOSIT TM 71 S Electroless Copper The CIRCUPOSIT 71 S Electroless Copper concentration should be between 50 100%. To raise the S content by 10%, add 0.2 ml/l of CIRCUPOSIT 71 S. CIRCUPOSIT 71 S concentration can be determined following the control procedure below. Page 6 of 12

CIRCUPOSIT TM 71 S Electroless Copper Control Procedure I. Equipment a) 100 ml beaker b) 10 ml graduated pipette c) 5 ml graduated pipette d) 250 ml separatory funnel e) 50 ml volumetric flask f) UV spectrophotometer II. Reagents a) ph 3.5 buffer solution; dissolve 40g of sodium acetate anhydrous and 300 ml of acetic acid (99.5%) in water; dilute to one liter b) Orange II Indicator; dissolve 1g of Orange II indicator in water; dilute to one liter c) Concentrated hydrochloric acid d) Trichloroethylene e) NaCl III. Procedure a) Pipette a 10 ml sample of CIRCUPOSIT 71 Electroless Copper bath into a beaker. b) Dilute to 50 ml with D.I. water. c) Add and dissolve 5 ml of ph 3.5 buffer solution and 5g of NaCl. d) Add 3 ml of 0.1% Orange II indicator. e) Adjust to ph 3.5 with concentrated HCl. f) Decant into a 250 ml separatory funnel. g) Add 40 ml of trichloroethylene. h) Shake for at least 5 minutes and allow to stand for at least 10 minutes. (Release gas at beginning of shaking.) i) Decant the trichloroethylene layer (bottom layer, orange color) into a dry 50 ml volumetric flask. j) Bring to 50 ml total with trichloroethylene and shake. k) Immediately measure absorbance (485 nm; Trichloroethylene reference). l) Obtain the concentration from the calibration curve. IV. Calculation Formula for linear portion of Dow Electronic Materials calibration curve from 0 to 200%. CIRCUPOSIT 71 S % = 230(ABS) - 2.89 V. Calibration Curve ABS 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 Absorbance vs. S Content % 0 25 50 75 100 125 150 175 200 Ingredient S Content (%) Page 7 of 12

CIRCUPOSIT TM 71 T Electroless Copper CIRCUPOSIT TM 71 T Electroless Copper Control Procedure The CIRCUPOSIT 71 T Electroless Copper concentration should be between 100 120%. To raise the T content by 10%, add 2.0 ml/l of CIRCUPOSIT 71 T. CIRCUPOSIT 71 T concentration can be determined following the control procedure below. I. Equipment a) Two-100 ml volumetric flasks b) 10 ml graduated pipette c) 5 ml transfer pipette d) Hot plate e) UV spectrophotometer II. Reagents a) 0.5% Sulfuric Acid b) Ammonium molybdate; dissolve 70g of ammonium molybdate 4H 2O in D.I. water; dilute to one liter c) Reference solution; pipette 5 ml plating solution and dilute to approximately 50 ml with D.I. water; bring to ph 3.3 3.5 with 5% III. sulfuric acid; bring to 100 ml in a volumetric flask Procedure a) Accurately pipette a 5 ml sample of CIRCUPOSIT 71 Electroless Copper bath into a volumetric flask. b) Dilute to 50 ml with D.I. water. c) Adjust ph to 3.3 3.5 with 5% sulfuric acid solution. d) Add 10 ml of ammonium molybdate (70 g/l) solution. e) Boil for 10 15 minutes. f) After cooling, bring to 100 ml in a volumetric flask. g) Measure absorbance; ABS (390 nm; reference solution as reference). h) Obtain the concentration from the calibration curve. IV. Calculation Formula for linear portion of Dow Electronic Materials calibration curve from 0 to 200%. CIRCUPOSIT 71 T % = 191(ABS) - 1.5 V. Calibration Curve ABS 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 Absorbance vs. T Content % 0 25 50 75 100 125 150 175 200 Ingredient T Content (%) Page 8 of 12

Replenishment Dilute CIRCUPOSIT 71 A Electroless Copper to 25% strength, CUPOSIT TM Y and CUPOSIT Z Additives to 50% strength. Replenishment of copper bath requires a continuous flow of replenishers. The exact flow of replenishers primarily depends on the bath loading and copper deposition rate. As a starting point, set the pump for a loading of 1.0 dm2/l (0.4 ft 2 / gal.) to replenish as follows: Replenishment Schedule 100 liter (26 gal.) bath 100 liter bath (ml/min.) CIRCUPOSIT 71 A Electroless Copper 8.8* CIRCUPOSIT 71 E 3.3 CIRCUPOSIT 71 S 0.11 CIRCUPOSIT 71 T 0.44 CIRCUPOSIT 71 U 0.55 CUPOSIT TM Y Additive 10.0* CUPOSIT Z 8.0* Adjust pump to maintain at level CIRCUPOSIT 71 A Cu content 3.05 g/l (0.41 oz./gal.) CIRCUPOSIT 71 E EDTA content ~43 g/l (5.7 oz./gal.) CIRCUPOSIT 71 U U content ~100% CIRCUPOSIT 71 T T content ~110% CIRCUPOSIT 71 S S content ~75% CUPOSIT Y Plating rate CUPOSIT Z ph = 12.0 12.1 *After dilution Bailout And Water Addition Typical Consumption For 378 Liter (100 Gallon) Bath The normal bailout rate is 15% of bath volume per cycle. Bath Volume: 100 liters (26 gallons) Bath Loading: 1.0 dm 2 /L (0.4 ft 2 /gallon) Plating Rate: 2.5 µm/hour (100 µin/hour) Bailout Rate: Should be 1.1 liter per hour (0.29 gal./hour) The hourly bailout volume is proportional to the plating rate and bath loading. Larger bailout will be needed to keep the specific gravity of the bath below 1.09. The volume of the bath should be maintained by manual or automatic level control. Typical total consumption for make-up and replenishment to run 4 cycles, based on 15% bailout rate, is as follows: Page 9 of 12

Typical Consumption for 378 liter (100 gallon) bath Make-up Total Consumption CIRCUPOSIT 71 E 64.3 liters (17 gal.) 104.0 liters (27.4 gal.) Electroless Copper CIRCUPOSIT 71 A 5.7 liters (1.5 gal.) 31.8 liters (8.4 gal.) CIRCUPOSIT 71 U 3.8 liters (1.0 gal.) 10.2 liters (2.7 gal.) CIRCUPOSIT 71 T 7.6 liters (2.0 gal.) 13.2 liters (3.5 gal.) CIRCUPOSIT 71 S 0.76 liters (0.2 gal.) 1.9 liters (0.5 gal.) CUPOSIT TM Y Additive 3.8 liters (1.0 gal.) 63.2 liters (16.7 gal.) CUPOSIT Z 3.8 liters (1.0 gal.) 51.5 liters (13.6 gal.) Typical total consumption for each cycle after 4 cycles, based on 50% bailout rate, is as follows: Typical Consumption for 378 liter (100 gallon) bath CIRCUPOSIT 71 E Electroless Copper Per Cycle Add. Total Consumption 19.7 liters (5.2 gal.) 123.4 liters (32.6 gal.) CIRCUPOSIT 71 A 7.57 liters (2.0 gal.) 39.4 liters (1.04 gal.) CIRCUPOSIT 71 U 3.4 liters (0.9 gal.) 13.6 liters (3.6 gal.) CIRCUPOSIT 71 T 3.0 liters (0.8 gal.) 16.3 liters (4.3 gal.) CIRCUPOSIT 71 S 0.38 liters (0.1 gal.) 2.3 liters (0.6 gal.) CUPOSIT TM Y 16.7 liters (4.4 gal.) 79.9 liters (21.1 gal.) CUPOSIT Z 13.6 liters (3.6 gal.) 65.1 liters (17.2 gal.) Equipment Tanks: Polypropylene, fluoropolymer or fluoropolymer-coated Heaters: Fluoropolymer or fluoropolymer-coated coils Filtration: Continuous bath circulation through 1 5 micron polypropylene filtration cartridges is mandatory; examine and replace cartridges as necessary Pump: External pump with intake from sump Process Lines: Polypropylene, Fluoropolymer-resin Air Lines: Rigid CPVC Plumbing: Rigid CPVC Product Data CIRCUPOSIT 71 E Electroless Copper Appearance: Blue ph: 12.5 Specific Gravity: 1.14 CIRCUPOSIT 71 A Appearance: Blue ph: <2.0 Specific Gravity: 1.45 CIRCUPOSIT 71 U Appearance: Blue ph: 2.0 Specific Gravity: 1.0 Page 10 of 12

CIRCUPOSIT TM 71 T Electroless Copper Appearance: Clear, colorless ph: 13.0 Specific Gravity: 1.05 CIRCUPOSIT 71 S Appearance: Blue ph: 10.5 Specific Gravity: 1.03 CUPOSIT TM Y Appearance: Clear, colorless ph: 6.0 Specific Gravity: 1.1 CUPOSIT Z Appearance: Clear, colorless ph: >12.0 Specific Gravity: 1.3 Page 11 of 12

Handling Precautions Before using this product, or the analytical reagents required for this control, consult the Material Safety Data Sheet (MSDS)/Safety Data Sheet (SDS) for details on material hazards, recommended handling precautions and product storage. CAUTION! Keep combustible and/or flammable products and their vapors away from heat, sparks, flames and other sources of ignition including static discharge. Processing or operating at temperatures near or above product flashpoint may pose a fire hazard. Use appropriate grounding and bonding techniques to manage static discharge hazards. CAUTION! Failure to maintain proper volume level when using immersion heaters can expose tank and solution to excessive heat resulting in a possible combustion hazard, particularly when plastic tanks are used. Storage Disposal Considerations Store products in tightly closed original containers at temperatures recommended on the product label. Dispose in accordance with all local, state (provincial) and federal regulations. Empty containers may contain hazardous residues. This material and its container must be disposed in a safe and legal manner. It is the user's responsibility to verify that treatment and disposal procedures comply with local, state (provincial) and federal regulations. Contact your Dow Electronic Materials Technical Representative for more information. Product Stewardship Customer Notice Dow has a fundamental concern for all who make, distribute, and use its products, and for the environment in which we live. This concern is the basis for our product stewardship philosophy by which we assess the safety, health, and environmental information on our products and then take approp riate steps to protect employee and public health and our environment. The success of our product stewardship program rests with each and every individual involved with Dow products - from the initial concept and research, to manufacture, use, sale, disposal, and recycle of each product. Dow strongly encourages its customers to review both their manufacturing processes and their applications of Dow products from the standpoint of human health and environmental quality to ensure that Dow products are not used in ways for which they are not intended or tested. Dow personnel are available to answer your questions and to provide reasonable technical support. Dow product literature, including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets are available from Dow. For Industrial Use Only. This information is based on our experience and is, to the best of our knowledge, true and accurate. However, since conditions for use and handling of products are beyond our control, we make no guarantee or warranty, expressed or implied, regarding the information, the use, handling, storage or possession of the products, or the applications of any process described herein or the results sought to be obtained. Nothing herein shall be construed as a recommendation to use any product in violation of any patent rights. Contact: North America: 1-800-832-6200 Japan: (+81) 3-5460-4696 Asia: (+852) 2680-6888 Europe: (+41) 41-259-44-44 http://www.dow.com Notice: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to Dow or the Company mean the Dow legal entity selling the products to Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Page 12 of 12