SOLDERON SC Process. For Electronic Finishing Applications. Deposits meet or exceed Military Specification Method 202F, Method 208F.

Similar documents
SOLDERON MHS-W MATTE TIN AND TIN-LEAD PROCESS

SOLDERON ST-200 For Electronic Finishing Applications

SOLDERON BLS For Electronic Finishing Applications

PALLADURE 200 Pure Palladium Process

PALLAMET 500 Palladium-Nickel

AURALL 305M Electrolytic Gold For Electronic Finishing Applications

SILVERON TM GT-101 Bright Silver Cyanide-Free Bright Electrolytic Silver For Electronic, Decorative and Industrial Finishing Applications

RONOVEL C AUROSPEED CVD

CIRCUPOSIT Neutralizer 3313 For PWB Metallization Applications

PREPOSIT Etch 748. For PWB Metallization Applications. For use in the CIRCUPOSIT 3000 Process. Bath Make-up Metric (for 100 liters)

TINGLO CULMO Bright Acid Tin Electroplating (with Starter/Brightener 2.5X) For Electronic Finishing Applications

COPPER GLEAM RG 11 Acid Copper Plating Process

NIPOSIT PM-980 W Semi-Bright Electroless Nickel Process For Industrial Finishing Applications

PALLAMERSE SMT 2000 For PWB Metallization Applications

CIRCUPOSIT 71 Full Build Electroless Copper Nitrate Bath (Generic Concentrates) For Electronic Finishing Applications

SILVER GLO 3KBP. With SILVER GLO 33BP Silver Plating Process For Electronic Finishing Applications. Silver M etal as Silver: Cyanide (80.

SILVER GLO 3K Silver Process

CHROME GLEAM 3C Jet Black Trivalent Chromium Plating Process

ROPAQUE OP-96 All-Purpose Pigment Engineered to Improve Waterborne Coatings

AVANSE ST-410 Acrylic Emulsion

PARALOID EXL-2690 IMPACT MODIFIER

NICKEL GLEAM BR 220 BRIGHT NICKEL PROCESS

PARALOID EXL 2314 Impact Modifier

PARALOID EXL-2655 Impact Modifier For Thermoset Applications

RHOPLEX EP-6060 Acrylic Polymer For Factory-Applied Wood Coatings

PARALOID EXL-2620 (Powder) MBS Impact Modifier For Polycarbonate, Polyesters and their Blends

CIRCUPOSIT Electroless Copper (USING CUPOSIT Z AND Y-1) For PWB Metallization Applications

ACUMER 9400 High-Performance Dispersant for Various Minerals

RHOPLEX SG-10M 100% Acrylic Emulsion For Interior/Exterior Semigloss Latex Paints

PARALOID EXL-5900 Optical Properties Modifier For Polycarbonate and Polystyrene

ROPAQUE Ultra E Opaque Polymer

Use vigorous air agitation while adding the components in the order shown: 2.7% by volume CIRCUPOSIT LC-9100C Electroless Copper

ACUMER 9300 Dispersant Polymer for Mineral Slurries

FASTRACK HD-21A Polymer Emulsion for Durable Waterborne Traffic Marking Paints

PARALOID AU-1033 Acrylic Polyol with Low Isocyanate Demand For Coatings on Recreational Equipment and Fleet Refinishing

IMPACT MODIFIER (21518XP) Maleic Anhydride (MAH) Grafted Polyolefin for Polyamide Applications

INTERVIA BPP-10 Photoresist

PARALOID AU-608 TBZ Acrylic Polyol For Auto Refinishing, GIF and Conventional Spray Applications, and Airless Spray Maintenance

OPTIDOSE 4210 Traceable Polymeric Acid Scale Inhibitor and Dispersant

PavCoTing. Chromium appearance and corrosion resistance Ease of plating bath control Wide current density range

ELECTROPOSIT 1100 Acid Copper

RHOPLEX MULTILOBE 400 Emulsion Polymer

PRIMAL SF-208ER Binder

NB SEMIPLATE AG 100 Ag electroplating process

ELECTROPOSIT 1100 B-2 Acid Copper Additive

NB SEMIPLATE CU 200 Copper electroplating process

ACUMER 2200 High Performance Scale Inhibitor

PARALOID TMS-2670 MBS Impact Modifier For Epoxy Resin Applications

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate

RHOPLEX WL-96 Waterborne Acrylic Polymer For Low VOC Interior Clear Wood Finishes

OPTIDOSE 1000 Traceable Polymer A Tool for Maintaining Maximum Heat Transfer

ROVACE 9400 Vinyl Acrylic Binder

PARALOID Edge 2301 Resin

Flexible Acrylic Resin XP Translucent Grade

RHOPLEX TP-257 Polymer Emulsion for Waterborne Traffic Marking Paints

OUDRASperse WB 3001 Waterborne Epoxy Dispersion

TAMOL 960 TAMOL 731A Scale Inhibitors

Tinmac Stannolyte Bright Acid Tin Solution

NB SEMIPLATE CU 150 Copper electroplating process

MAINCOTE 1100A Emulsion Advanced Resin for Industrial Coatings based on AVANSE Technology Platform

UV5 POSITIVE DUV PHOTORESIST For Microlithography Applications

TINPOSIT LT-26 IMMERSION TIN For PWB Metallization Applications

RHOPLEX MV-23LO Emulsion Copolymer For Wood Primers and Stain Blocking Sealers

Lumina. Bright, leveled deposits in less time Excellent ductility Good chromium reception Very low additive consumption rate. Nickel Plating System

MAINCOTE 1071 Emulsion

Manufactured for North America exclusively by Automated Chemical Solutions, Inc E. Roeser Road Phoenix, Arizona 85040

PARALOID AE-1285 Acrylic Curing Agent For Isocyanate-Free, High-Solids, Durable Topcoats

E-Brite 30/30. Non-Cyanide Alkaline Copper Plating

TECHNICAL BULLETIN IMMERSION SILVER - IS150

Technical Data Sheet. Physical Specifications

Alkzinc 818. Mirror bright finish Good zinc deposit distribution Very good adhesion and ductility Excellent chromate receptivity

OUDRASperse WB 4001 Waterborne Epoxy Dispersion

NB SEMIPLATE AU 100 Bright Au electroplating process, sulfite based, arsenic grain refiner

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

ELASTENE 404 Binder. Pure Acrylic Binder For Elastomeric Coatings. * Manufactured without the use of APEO surfactants

DOW Specialty Membrane XUS and XUS Reverse Osmosis Elements

SurTec 881 Trivalent Decorative Chromium Process

NB SEMIPLATE AU 100 TH Bright Au electroplating process, sulfite-based, arsenic-free

Enerox Nickel Additive E 44 Product Code: Revised Date: 09/26/2007

HyProTec. Hexavalent free RoHS, ELV and WEEE compliant. HyPro System

Technical Process Bulletin

UCARSOL GT 900 Antifoam

Technical Data Sheet

4831 S. Whipple Avenue Chicago IL Phone: Fax:

HAVALLOY Z-C ACID CHLORIDE ZINC / COBALT PROCESS

Zinc Alloy Plating Ziniloy

Enerox Nickel Additive E 66 Product Code: Revised Date: 02/28/2012. Enerox Nickel Additive E 66 High End Rack Plating

AMBERLITE IRN160 H/OH Ion Exchange Resin

4831 S. Whipple Avenue Chicago IL Phone: Fax:

MICROFAB PB 200 High purity lead or lead-tin plating process for semiconductor applications

COLORMAX 9000C: Stannous Based Electrolytic Colouring Process

Capstan drive units Mechanical handling rollers

DURNI-COAT DNC

-.O oz/gal. It is again desirable to have some means of mechanical agitation.

NITEC CRYSTAL 1. Elektrolyt to achieve uniform and non reflective Nickel deposits

AMP-95. Key Performance Advantages. (2-amino-2-methyl-1-propanol containing 5% water) Multifunctional Additive for Latex Paints

SURECEL 445 FOAM CELL PROMOTER

NORKOOL Industrial Coolants

Immersion Tin SN 30 1

Short Form Guide Specification. STYROFOAM CAVITYMATE Ultra Air Barrier Wall System

Transcription:

Technical Data sheet SOLDERON SC Process For Electronic Finishing Applications REGIONAL PRODUCT AVAILABILITY DESCRIPTION N. America Japan/Korea Asia Europe SOLDERON SC is a low-foaming, organic sulfonate electroplating process for the high-speed deposition of uniform, fine-grain, matte tin and tin/lead alloy coatings. SOLDERON SC Process is specifically designed for use in highspeed magazine-to-magazine and reel-to-reel electroplating equipment, where the process versatility is particularly well-suited for semiconductor lead frame and electronic connector applications. ADVANTAGES Very low-foaming electrolyte Extremely stable alloy and thickness distribution across the operating current density range Outstanding performance at high current densities Uniform deposit appearance DEPOSIT PROPERTIES Structure/Appearance: Alloy Composition: Fine grained, matte 60 100% Tin, 0 40% Lead Deposits meet or exceed Military Specification Method 202F, Method 208F. % CO-DEPOSITED CARBON Conditions: 90/10 Sn/Pb Alloy, 45 C, 10 A/dm 2 ; SOLDERON Acid HC 215 ml/l Additive Content % Co-deposited Carbon 50 ml/l SC Primary, 2 ml/l SC Secondary 0.0037 100 ml/l SC Primary, 4 ml/l SC Secondary 0.0049 150 ml/l SC Primary, 6 ml/l SC Secondary 0.0064 Page 1 of 12 SOLDERON SC Process/ Interconnect Technologies

BATH MAKE-UP Refer to specific alloy solution make-up procedures for exact quantities. Chemicals Required 1. SOLDERON Tin HS-300 Concentrate 2. SOLDERON Lead Concentrate 3. SOLDERON Acid HC 4. SOLDERON SC Primary 5. SOLDERON SC Secondary 6. SOLDERON RD Concentrate MAKE-UP PROCEDURE 1. Add deionized water to tank. 2. Add SOLDERON Acid HC and mix thoroughly. 3. Add SOLDERON Tin HS-300 Concentrate and mix thoroughly. 4. Add SOLDERON Lead Concentrate and mix thoroughly. 5. Add SOLDERON SC Primary and mix thoroughly. 6. Add SOLDERON SC Secondary and mix thoroughly. 7. Add SOLDERON RD Concentrate and mix thoroughly. 8. Dilute to final volume with deionized water. Note: SOLDERON Tin and Lead Concentrates contain SOLDERON Acid HC. These components contribute to the total concentration of SOLDERON Acid HC in the electroplating process. SOLDERON SC Primary contains SOLDERON RD Concentrate and will contribute to the total concentration of SOLDERON RD Concentrate in the solution. Bath Operation Metric SOLDERON SC Primary 75.0 125.0 ml/l 100.0 ml/l SOLDERON SC Secondary SOLDERON RD Concentrate 3 7 ml/l 5.0 ml/l 10 20 ml/l 15 ml/l Temperature 40 60 C 45 C Cathode Current Density 5 30 A/dm 2 Dependent upon equipment design and production requirements Anode to Cathode Ratio Agitation 1:1 minimum Cathode Efficiency 95 100% Moderate solution coupled with cathode movement Deposition Rate 5.0 microns per minute at 10 A/dm 2 Page 2 of 12

Bath Operation U.S. Parameter Range Optimum SOLDERON SC Primary 7.5 12.5% v/v 10.0% v/v SOLDERON SC Secondary 0.3 0.7% v/v 0.5% v/v SOLDERON RD Concentrate 1.0 2.0% v/v 1.5% v/v Temperature 105 140 F 115 F Cathode Current Density 50 300 A/ft 2 Dependent upon equipment design and production requirements Anode to Cathode Ratio Agitation 1:1 minimum Cathode Efficiency 95 100% Moderate solution coupled with cathode movement Deposition Rate 200 microinches per minute at 100 A/ft 2 PRE-TREATMENT A final activation step of 7 14% SOLDERON Acid HC with cathodic current is recommended prior to entering the electroplating cell. Bath Make-up Pure Tin Metric Parameter 5 15 A/dm 2 15 30 A/dm 2 Deionized Water 400 ml/l 350 ml/l SOLDERON Tin HS-300 Concentrate 150 ml/l 215 ml/l SOLDERON Acid HC 110 ml/l 70 ml/l SOLDERON SC Primary 100 ml/l 100 ml/l SOLDERON SC Secondary 5 ml/l 5 ml/l SOLDERON RD Concentrate 10 ml/l 10 ml/l Dilute to final volume with deionized water Bath Make-up Pure Tin U.S. Parameter 50 150 A/ft 2 150 300 A/ft 2 Deionized Water 40% v/v 35% v/v SOLDERON Tin HS-300 Concentrate 15% v/v 21.5% v/v SOLDERON Acid HC 11% v/v 7% v/v SOLDERON SC Primary 10% v/v 10% v/v SOLDERON SC Secondary 0.5% v/v 0.5% v/v SOLDERON RD Concentrate 1.0% v/v 1.0% v/v Dilute to final volume with deionized water Page 3 of 12

Bath Operation Pure Tin (5 15 A/dm 2 ) Metric Tin (II) 35.0 55.0 g/l 45.0 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Bath Operation Pure Tin (15 30 A/dm 2 ) Metric Tin (II) 55.0 75.0 g/l 65.0 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Bath Operation Pure Tin (50 150 A/ft 2 ) U.S. Tin (II) 4.7 7.3 oz./gal. 6.0 oz./gal. SOLDERON Acid HC 18.0 25.0% v/v 21.5% v/v Bath Operation Pure Tin (150 300 A/ft 2 ) U.S. Tin (II) 7.3 10.0 oz./gal. 8.7 oz./gal. SOLDERON Acid HC 18.0 25.0% v/v 21.5% v/v Bath Make-up 90/10 Tin-Lead Alloy Metric Chemicals Required 5 15 A/dm 2 15 30 A/dm 2 Deionized Water 400 ml/l 350 ml/l SOLDERON Tin HS-300 Concentrate 130 ml/l 200 ml/l SOLDERON Lead Concentrate 9 ml/l 13 ml/l SOLDERON Acid HC 120 ml/l 80 ml/l SOLDERON SC Primary 100 ml/l 100 ml/l SOLDERON SC Secondary 5 ml/l 5 ml/l SOLDERON RD Concentrate 10 ml/l 10 ml/l Dilute to final volume deionized water Page 4 of 12 Bath Make-up 90/10 Tin-Lead Alloy U.S. Chemicals Required 50 150 A/dm 2 150 300 A/dm 2 Deionized Water 40% v/v 35% v/v SOLDERON Tin HS-300 Concentrate 13% v/v 20% v/v SOLDERON Lead Concentrate 0.9% v/v 1.3% v/v SOLDERON Acid HC 12% v/v 8% v/v SOLDERON SC Primary 10% v/v 10% v/v SOLDERON SC Secondary 0.5% v/v 0.5% v/v SOLDERON RD Concentrate 1.0% v/v 1.0% v/v Dilute to final volume deionized water

90/10 Tin-Lead Alloy Bath Operation (5 15 A/dm 2 ) Metric Tin (II) 30.0 50.0 g/l 40.0 g/l Lead 3.0 5.0 g/l 4.0 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Tin:Lead in Solution 8:1 to 12:1 10:1* 90/10 Tin-Lead Alloy Bath Operation (15 30 A/dm 2 ) Metric Tin (II) 50 70 g/l 60 g/l Lead 5.0 7.0 g/l 6.0 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Tin:Lead in Solution 8:1 to 12:1 10:1* *Note: This ratio may vary depending on agitation, temperature and current density. 90/10 Tin-Lead Alloy Bath Operation (50 150 A/ft 2 ) U.S. Tin (II) 4.0 6.7 oz./gal. 5.3 oz./gal. Lead 0.4 0.7 oz./gal. 0.5 oz./gal. SOLDERON Acid HC 18.0 25.0% v/v 21.5% v/v Tin:Lead in Solution 8:1 to 12:1 10:1* 90/10 Tin-Lead Alloy Bath Operation (150 300 A/ft 2 ) U.S. Tin (II) 6.7 9.3 oz./gal. 8.0 oz./gal. Lead 0.7 0.9 oz./gal. 0.8 oz./gal. SOLDERON Acid HC 18.0 25.0% v/v 21.5% v/v Tin:Lead in Solution 8:1 to 12:1 10:1* *Note: This ratio may vary depending on agitation, temperature and current density. Page 5 of 12

Bath Make-up 85/15 Tin-Lead Alloy Metric Chemicals Required 5 15 A/dm 2 15 30 A/dm 2 Deionized Water 400 ml/l 350 ml/l SOLDERON Tin HS-300 Concentrate 130 ml/l 200 ml/l SOLDERON Lead Concentrate 16 ml/l 22 ml/l SOLDERON Acid HC 120 ml/l 80 ml/l SOLDERON SC Primary 100 ml/l 100 ml/l SOLDERON SC Secondary 5 ml/l 5 ml/l SOLDERON RD Concentrate 10 ml/l 10 ml/l Dilute to final volume deionized water Bath Make-up 85/15 Tin-Lead Alloy U.S. Chemicals Required 50 150 A/dm 2 150 300 A/dm 2 Deionized Water 40% v/v 35% v/v SOLDERON Tin HS-300 Concentrate 13% v/v 20% v/v SOLDERON Lead Concentrate 1.6% v/v 2.2% v/v SOLDERON Acid HC 12% v/v 8% v/v SOLDERON SC Primary 10% v/v 10% v/v SOLDERON SC Secondary 0.5% v/v 0.5% v/v SOLDERON RD Concentrate 1.0% v/v 1.0% v/v Dilute to final volume deionized water 85/15 Tin-Lead Alloy Bath Operation (5 15 A/dm 2 ) Metric Tin (II) 30.0 50.0 g/l 40.0 g/l Lead 4.0 10 g/l 7.0 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Tin:Lead in Solution 4:1 to 8:1 6:1* Page 6 of 12 85/15 Tin-Lead Alloy Bath Operation (15 30 A/dm 2 ) Metric Tin (II) 50 70 g/l 60 g/l Lead 8 12 g/l 10 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Tin:Lead in Solution 4:1 to 8:1 6:1* *Note: This ratio may vary depending on agitation, temperature and current density.

85/15 Tin-Lead Alloy Bath Operation (50 150 A/ft 2 ) U.S. Tin (II) 4.0 6.7 oz./gal. 5.3 oz./gal. Lead 0.5 1.3 oz./gal. 1.0 oz./gal. SOLDERON Acid HC 18 25.0% v/v 21.5% v/v Tin:Lead in Solution 4:1 to 8:1 6:1* 85/15 Tin-Lead Alloy Bath Operation (150 300 A/ft 2 ) U.S. Tin (II) 6.7 9.3 oz./gal. 8.0 oz./gal. Lead 1.1 1.6 oz./gal. 1.3 oz./gal. SOLDERON Acid HC 18.0 25.0% v/v 21.5% v/v Tin:Lead in Solution 4:1 to 8:1 6:1* *Note: This ratio may vary depending on agitation, temperature and current density. Bath Make-up 60/40 Tin-Lead Alloy Metric Chemicals Required 5 15 A/dm 2 15 30 A/dm 2 Deionized Water 400 ml/l 400 ml/l SOLDERON Tin HS-300 Concentrate 100 ml/l 150 ml/l SOLDERON Lead Concentrate 33 ml/l 49 ml/l SOLDERON Acid HC 135 ml/l 100 ml/l SOLDERON SC Primary 100 ml/l 100 ml/l SOLDERON SC Secondary 5 ml/l 5 ml/l SOLDERON RD Concentrate 10 ml/l 10 ml/l Dilute to final volume deionized water Bath Make-up 60/40 Tin-Lead Alloy U.S. Chemicals Required 50 150 A/dm 2 150 300 A/dm 2 Deionized Water 40% v/v 40% v/v SOLDERON Tin HS-300 Concentrate 10% v/v 15% v/v SOLDERON Lead Concentrate 3.3% v/v 4.9% v/v SOLDERON Acid HC 13.5% v/v 10% v/v SOLDERON SC Primary 10% v/v 10% v/v SOLDERON SC Secondary 0.5% v/v 0.5% v/v SOLDERON RD Concentrate 1.0% v/v 1.0% v/v Dilute to final volume deionized water Page 7 of 12

60/40 Tin-Lead Alloy Bath Operation (5 15 A/dm 2 ) Metric Tin (II) 25.0 35.0 g/l 30.0 g/l Lead 10 20 g/l 15 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Tin:Lead in Solution 1:1 to 3:1 2:1* 60/40 Tin-Lead Alloy Bath Operation (15 30 A/dm 2 ) Metric Tin (II) 35.0 55.0 g/l 45.0 g/l Lead 17 27 g/l 22.0 g/l SOLDERON Acid HC 180 250 ml/l 215 ml/l Tin:Lead in Solution 1:1 to 3:1 2:1* *Note: This ratio may vary depending on agitation, temperature and current density. 60/40 Tin-Lead Alloy Bath Operation (50 150 A/ft 2 ) U.S. Tin (II) 3.3 4.7 oz./gal. 4.0 oz./gal. Lead 1.3 2.7 oz./gal. 2.0 oz./gal. SOLDERON Acid HC 18 25.0% v/v 21.5% v/v Tin:Lead in Solution 1:1 to 3:1 2:1* 60/40 Tin-Lead Alloy Bath Operation (150 300 A/ft 2 ) U.S. Tin (II) 4.7 7.4 oz./gal. 6.0 oz./gal. Lead 2.3 3.6 oz./gal. 3.0 oz./gal. SOLDERON Acid HC 18.0 25.0% v/v 21.5% v/v Tin:Lead in Solution 1:1 to 3:1 2:1* *Note: This ratio may vary depending on agitation, temperature and current density. Page 8 of 12

BATH MAINTENANCE SOLDERON SC Primary SOLDERON SC Primary is required upon make-up to achieve smooth uniform deposits. Replenish SOLDERON SC Primary at a rate of 100 200 ml every 1,000 ampere hours or as required based on analysis to maintain the concentration between 75 125 ml/l (7.5 12.5% v/v). See the analytical procedure for the determination of SOLDERON SC Primary Concentration by CVS. SOLDERON SC Secondary SOLDERON SC Secondary is required upon make-up to achieve desired deposit properties such as thickness uniformity and alloy distribution. Replenish SOLDERON SC Secondary at a rate of 20 50 ml every 1,000 ampere hours or as required based on analysis to maintain the concentration between 3 7 ml/l (0.3 0.7% v/v). See the analytical procedure for the determination of SOLDERON SC Secondary Concentration by UV/VIS Spectrophotometry. SOLDERON SC Primary and SOLDERON SC Secondary may be pre-mixed for use in automatic replenishment systems. Upon establishing the individual consumption rates of SOLDERON SC Primary and Secondary using the analytical procedures described above, the ratio of these materials in the premix can be customized to satisfy specific application requirements. It is recommended that the SOLDERON SC Primary and SOLDERON SC Secondary be pre-mixed in quantities that will require no longer than a one week storage period. SOLDERON Tin HS-300 Concentrate SOLDERON Tin HS-300 Concentrate contains 300 g/l (40 oz./gal.) of tin (II). To raise tin (II) concentration 1.0 g/l (0.13 oz./gal.), add 3.33 ml/l (0.33% v/v) SOLDERON Tin HS-300 Concentrate. SOLDERON Lead Concentrate SOLDERON Lead Concentrate contains 450 g/l (60.0 oz./gal.) of lead. To raise lead concentration 1.0 g/l (0.13 oz./gal.), add 2.2 ml/l (0.22% v/v) SOLDERON Lead Concentrate. SOLDERON Acid HC To raise acid concentration 1% by volume, add 10 ml/l SOLDERON Acid HC. SOLDERON RD Concentrate SOLDERON RD Concentrate is designed to aid in minimizing the oxidation of stannous tin. An initial addition of 10 ml/l SOLDERON RD Concentrate to the solution is recommended. Replenish SOLDERON RD Concentrate at a rate of 40 ml every 1,000 ampere hours or as required based on analysis to maintain the concentration between 10 20 ml/l (1.0 2.0% v/v) using the analytical procedure. Page 9 of 12

EQUIPMENT Tanks: Polypropylene, Polyethylene or PVDC Anodes: Tin or Tin-Lead alloy balls or slugs Soluble: in Type 316 stainless steel baskets; Tin or Tin-Lead alloy slabs; A range of anode compositions can be utilized depending on desired deposit composition and operational parameters Note: Anode baskets must be kept full at all times. Insoluble: Platinized Titanium Anode Bags: Anodes should be contained in polypropylene or equivalent anode bags to prevent the anode film particulates from entering the solution Heaters: Titanium, Silica-sheathed or Teflon fluoropolymer-coated Filtration: Continuous, 1 micron polypropylene filter cartridge EQUIPMENT PREPARATION Prior to make-up, the process tank and ancillary equipment should be thoroughly cleaned and then leached with a SOLDERON Acid HC solution. This procedure is particularly important for new equipment or equipment previously used for other processes, for example, fluoboric-acid-based systems. I. Cleaning Solution a) Trisodium Phosphate: 15 g/l (2 oz./gal.) b) Sodium Hydroxide: 15 g/l (2 oz./gal.) II. Leaching Solution SOLDERON Acid HC: 70 ml/l (7% v/v) III. Procedure a) Thoroughly wash down tank and ancillary equipment with clean water. b) Recirculate water through the complete system to remove water soluble materials. c) Discard water. d) Add cleaning solution to the tank, heat to 55 60 C (130 140 F) and recirculate through the complete system for 1 4 hours. e) Discard cleaning solution. f) Recirculate water through the complete system. g) Discard water. h) Add leaching solution and recirculate through the complete system. i) Leave leaching solution in the tank for a minimum of 8 hours. j) Recirculate leaching solution through the complete system. k) Discard leaching solution. l) Recirculate water through the complete system. m) Discard water. Page 10 of 12

PRODUCT DATA SOLDERON SC Primary Appearance: Clear, colorless liquid ph: <2.0 Specific Gravity: 1.010 SOLDERON SC Secondary Appearance: Clear, dark blue/black liquid ph: 4.5 Specific Gravity: 1.038 SOLDERON Tin HS-300 Concentrate Appearance: Colorless to yellow liquid ph: 1.0 Specific Gravity: 1.55 SOLDERON Lead Concentrate Appearance: Clear, colorless to pale yellow liquid ph: <2.0 Specific Gravity: 1.60 SOLDERON Acid HC Appearance: Clear, colorless to pale yellow liquid ph: <1.0 Specific Gravity: 1.35 SOLDERON RD Concentrate Appearance: Clear, colorless to pink/amber liquid ph: <1.0 Specific Gravity: 1.043 Note: These are typical properties, not to be construed as specifications. Page 11 of 12

Handling Precautions Before using this product, associated generic chemicals or the analytical reagents required for this control, consult the supplier s Material Safety Data Sheet (MSDS)/Safety Data Sheet (SDS) for details on material hazards, recommended handling precautions and product storage. CAUTION! Keep combustible and/or flammable products and their vapors away from heat, sparks, flames and other sources of ignition including static discharge. Processing or operating at temperatures near or above product flashpoint may pose a fire hazard. Use appropriate grounding and bonding techniques to manage static discharge hazards. CAUTION! Failure to maintain proper volume level when using immersion heaters can expose tank and solution to excessive heat resulting in a possible combustion hazard, particularly when plastic tanks are used. Storage Disposal Considerations Store products in tightly closed original containers at temperatures recommended on the product label. Dispose in accordance with all local, state (provincial) and federal regulations. Empty containers may contain hazardous residues. This material and its container must be disposed in a safe and legal manner. It is the user's responsibility to verify that treatment and disposal procedures comply with local, state (provincial) and federal regulations. Contact your Dow Electronic Materials Technical Representative for more information. Product Stewardship Customer Notice Dow has a fundamental concern for all who make, distribute, and use its products, and for the environment in which we live. This concern is the basis for our product stewardship philosophy by which we assess the safety, health, and environmental information on our products and then take appropriate steps to protect employee and public health and our environment. The success of our product stewardship program rests with each and every individual involved with Dow products from the initial concept and research, to manufacture, use, sale, disposal, and recycle of each product. Dow strongly encourages its customers to review both their manufacturing processes and their applications of Dow products from the standpoint of human health and environmental quality to ensure that Dow products are not used in ways for which they are not intended or tested. Dow personnel are available to answer your questions and to provide reasonable technical support. Dow product literature, including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets are available from Dow. For Industrial Use Only. This information is based on our experience and is, to the best of our knowledge, true and accurate. However, since conditions for use and handling of products are beyond our control, we make no guarantee or warranty, expressed or implied, regarding the information, the use, handling, storage or possession of the products, or the applications of any process described herein or the results sought to be obtained. Nothing herein shall be construed as a recommendation to use any product in violation of any patent rights. Contact: North America: 1-800-832-6200 Japan: (+81) 3-5460-4696 Asia: (+852) 2680-6888 Europe: (+41) 41-259-44-44 http://www.dow.com Notice: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to Dow or the Company mean the Dow legal entity selling the products to Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Page 12 of 12