Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

Similar documents
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Method to 500 µg/l CH 2 O Powder Pillows

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

Table 163 Instrument-specific information. Instrument Pour-thru Kit Cell orientation Adapter. DR 6000 LQV Arrow faces right

Phosphorus, Reactive (Orthophosphate)

Phosphorus, Reactive (Orthophosphate)

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

3. Fill a 50-mL. 2. Press: 1 ENTER The display will show mg/l, Al and the ZERO icon.

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters.

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

TPTZ Method * (Powder Pillows or AccuVac Ampuls) Using Powder Pillows

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Scope and application: For water and wastewater. Turbid samples are filtered during the analysis.

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

DR/4000 PROCEDURE. IRON, Ferrous. Using Powder Pillows

FerroVer Method (Powder Pillows or AccuVac Ampuls) USEPA approved for reporting wastewater analysis (digestion is required; see Section 2 * )

Phosphorus, Reactive (Orthophosphate)

Nitrogen, Simplified TKN (s-tkn ) DOC

Oxygen Demand, Chemical

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

Sulfate DOC SulfaVer 4 Method 1. Method (0 70, and mg/l) Powder Pillows. Test procedure

Oxygen Demand, Chemical

Oxygen Demand, Chemical

Color, True and Apparent, LR

PHOSPHORUS, REACTIVE (0.00 to 5.00 mg/l PO 4

Oxygen Demand, Chemical

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette

Instrument Adapters Light shield DR 6000, DR 5000 DR 3900 LZV849 DR 3800, DR 2800 LZV646 DR or (A)

Amperometric Titrator assembly. Digital Titrator. Beaker, low-form, 250-mL. Stir bar, octagonal, Teflon-coated, 50.8 x 7.9 mm

1,5-Diphenylcarbohydrazide Method* (Powder Pillows or AccuVac Ampuls) USEPA accepted for wastewater analyses** Using Powder Pillows

3. Fill a 50-mL. 2. Press: 1 ENTER The display will show mg/l, Al and the ZERO icon.

Nitrogen, Simplified TKN (s-tkn )

Hardness, Calcium/Magnesium

PaSEC Colorimeter Instructions DR850

DR/4000 PROCEDURE OXYGEN SCAVENGERS. 4. Fill a second sample cell (the blank) with 25 ml of deionized water.

Oxygen Demand, Biochemical

Direct ISE Method Method to 4.00 mg/l NO 3 N Nitrate ISE

Professional Boiler Water Test Kit

Heterotrophic Bacteria

STP (off-line) Water Technologies & Solutions analytical procedure. colorimetric method DCA reagent 1 (5/5/1) 2 to 15 mg/l as STP

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

Direct ISE Method Method to 10.0 mg/l F Fluoride ISE

1,10 Phenanthroline Method * (Powder Pillows or AccuVac Ampuls) Using Powder Pillows

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm

Coliforms, Total and E. coli

GB (GB/T )

Cu (s) Cu 2+ (aq) Cu(OH) 2 (s) CuO (s) Cu 2+ (aq) Cu (s)

Uranium Testing and On Site Calibration for Water Testing Detection Range: 2 60ppb

Analysis of dissolved nitrite (NO 2- )

The determination of copper in brass

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Background The document will be revised for its five year review and updated per the committee agreed upon changes.

NACA Laboratory Equipment and Supplies

Background Statement for SEMI Draft Document 4795 (Yellow Ballot) NEW STANDARD: SPECIFICATIONS FOR NITRIC ACID, USED IN PHOTOVOLTAIC APPLICATIONS

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

INSTRUCTION MANUAL. ba76126e01 03/2013. photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y

TESTING THE WATERS HOW GOOD IS THAT BOTTLED WATER AND HOW EFFECTIVE IS YOUR WATER FILTER

M. It is expressed in units such a g/cc,

Suspended Metals Digestion Procedure

CHM Gravimetric Chloride Experiment (r7) 1/5

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Human Myostatin, ELISA Kit (MSTN)

InfraCal 2 Analyzer. User s Guide. Model ATR-SP. WilksIR.com

Chem 2115 Experiment #9. Consumer Chemistry: Determining the Iron Content in Supplements

Partner: Cathy 22 March Separation and Qualitative Determination of Cations and Anions

Determination of Aluminum by Fluorometry

Analysis of Calcium Carbonate Tablets

TYPES OF CHEMICAL REACTIONS PART I INTRODUCTION

CTRP15/MYONECTIN (HUMAN) ELISA KIT

HUMAN SOLUBLE HEAT SHOCK PROTEIN 70 (HSP70) ELISA KIT

HUMAN PLASMA (SOLUBLE) GELSOLIN ELISA KIT

Ti-Pure TITANIUM DIOXIDE. CONCENTRATED ACID SOLUBILITY OF TiO 2 METHOD: T WP

Method 108C - Determination of Arsenic Content in Ore Samples From Nonferrous Smelters (Molybdenum Blue Photometric Procedure)

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Guinea pig Carboxy Terminal. Propeptide of Type 1 Procollagen. (PICP) ELISA kit

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

PHYSICAL CHANGE OR CHEMICAL CHANGE?

Name Honors Chemistry / /

MAROOCHYDORE SHS. Student booklet. Including. ame: Teacher: Name. er: Maroochydore SHS Chemistry Department

HUMAN INTERLEUKIN 33 (IL-33) ELISA KIT

HUMAN TOTAL MATRIX METALLOPROTEINASE 1 (MMP-1) ELISA KIT

HUMAN CONNECTIVE TISSUE GROWTH FACTOR (CTGF) ELISA KIT

SEMI C SPECIFICATIONS AND GUIDELINES FOR AMMONIUM HYDROXIDE

CONSERVATION OF MATTER AND CHEMICAL PROPERTIES

PavCoTing. Chromium appearance and corrosion resistance Ease of plating bath control Wide current density range

HUMAN HIGH SENSITIVE C- REACTIVE PROTEIN (CRP) ELISA KIT

Why Hach Reagents? Alphabetical Listing of Reagents

Determination of the Mass Percentage of Copper in a Penny

MOUSE OPG ELISA KIT PAGE

RAT PROPROTEIN CONVERTASE SUBTILISIN /KEXIN TYPE 9 (PCSK9) ELISA KIT

(aq) + 5e - Mn 2+ (aq) + 4H 2

Transcription:

, 8017 Dithizone Method 1 DOC316.53.01012 Method 8017 (0.7 to 80.0 µg/l) Powder Pillows Scope and Application: For water and wastewater; digestion is required to determine total cadmium. 1 Adapted from Standard Methods for the Examination of Water and Wastewater (method 3500 Cd D). Test preparation How to use instrument-specific information The Instrument-specific information table displays requirements that may vary between instruments. To use this table, select an instrument then read across to find the corresponding information required to perform this test. Table 61 Instrument-specific information Instrument Sample cell Cell orientation DR 6000 2495402 Fill line faces right DR 5000 2495402 Fill line faces user DR 3900 2495402 Fill line faces user DR 3800, DR 2800, DR 2700 2495402 Fill line faces right Before starting the test: For more accurate results, determine a reagent blank value for each new lot of reagent. Follow the procedure using deionized water instead of the sample. Clean all glassware with 6 N Hydrochloric Acid Solution and rinse with deionized water. Sample cell orientation may vary. Refer to the instrument user manual for correct cell orientation. Cloudy and turbid samples may require filtering before running the test. Report results as µg/l soluble cadmium. Use glass membrane type filter to avoid loss of cadmium by adsorption onto the filter paper. If samples cannot be analyzed immediately, see Sample collection, preservation and storage. Adjust the ph of preserved samples before analysis. The Flow Cell and Sipper Modules cannot be used with this procedure. The DithiVer powder will not completely dissolve in the chloroform. For further notes see Dithiver solution preparation and storage. Read the MSDS before testing. Spilled reagent will affect test accuracy and is hazardous to skin and other materials. Goggles and gloves are recommended. In bright light conditions (e.g. direct sunlight) it may be necessary to close the cell compartment with the protective cover during measurements. Page 1 of 8

Collect the following items: Description Quantity Citrate buffer powder pillows 1 Chloroform 30 ml DithiVer Metals Reagent powder pillows 1 Potassium Cyanide Sodium Hydroxide solution, 50% 0.1 g 20 ml Cotton balls 1 Clippers 1 Cylinder, 25-mL graduated 1 Cylinder, 250-mL graduated 1 Cylinder, 50-mL graduated mixing 1 Funnel, 500-mL separatory 1 Sample Cells 2 Spoon, measuring, 0.1-g 1 Support ring (4-inch) and stand (5 x 8-inch base) 1 See Consumables and replacement items for reorder information. Dithizone method with powder pillows DANGER Cyanide is a deadly poison. Use a fume hood. Maintain cyanide solutions at ph 11 or greater to prevent formation of cyanide gas. Stored Programs 60, Dithizone Start 1. Select the test. Insert an adapter if required (see Instrumentspecific information). Refer to the user manual for orientation. 2. Fill a 250-mL graduated cylinder to the 250-mL mark with sample. Pour the sample into a 500-mL separatory funnel. 3. Add the contents of one Buffer Powder Pillow for heavy metals, citrate type. Stopper the funnel and shake to dissolve. 4. DithiVer Solution Preparation: Add 30 ml of chloroform to a 50-mL mixing graduated cylinder. Add the contents of one DithiVer Metals Reagent Powder Pillow. Stopper the cylinder. Invert several times to mix. Page 2 of 8

Dithizone method with powder pillows (continued) 5. Add 20 ml of 50% Sodium Hydroxide Solution to the funnel. 6. Add a 0.1-g scoop of potassium cyanide to the funnel. Stopper. Shake vigorously for 15 seconds. 7. Remove the stopper. Start the instrument timer. A 1-minute reaction period will begin. 8. Add 30 ml of the DithiVer solution to the 500-mL separatory funnel. Stopper, invert, and open stopcock to vent. Close the stopcock and shake funnel once or twice; vent again. 9. Start the instrument timer. Close the stopcock and shake the funnel vigorously during the 1-minute time period. 10. Start the instrument timer and allow the funnel to stand undisturbed until the timer expires. The bottom (chloroform) layer will be orange to pink if cadmium is present. 11. Prepared Sample: Insert a cotton plug the size of a pea into the delivery tube of the funnel and slowly drain the bottom (chloroform) layer into a dry 25-mL sample cell (the prepared sample). Stopper. The cadmium-dithizone complex is stable for more than one hour if the sample cell is kept tightly capped and out of direct sunlight. 12. Blank Preparation: Fill a dry sample cell with at least 10 ml of chloroform. Stopper. Page 3 of 8

Dithizone method with powder pillows (continued) Zero Read 13. Insert the blank into the cell holder. 14. ZERO the instrument. The display will show: 0.0 µg/l Cd 15. Insert the prepared sample into the cell holder. 16. READ the results in µg/l cadmium. Interferences Table 62 Interfering substances Interfering substance Highly buffered samples or extreme sample ph Bismuth Copper Mercury Silver Interference level May exceed the buffering capacity of the reagents and require sample pretreatment. Greater than 80 mg/l. See treatment below. Greater than 2 mg/l. See treatment below. All levels. See treatment below. Greater than 2 mg/l. See treatment below. To eliminate interference from the metals listed in the Interfering substances table, insert the following steps into the procedure after step 4. 1. Measure approximately 5 ml of the DithiVer solution into the separatory funnel. Stopper the funnel, invert and open the stopcock to vent. Close the stopcock and shake the solution vigorously for 15 seconds. Allow the funnel to stand undisturbed until the layers separate (about 30 seconds). A yellow, red, or bronze color in the bottom (chloroform) layer confirms the presence of interfering metals. Draw off and collect the bottom (chloroform) layer for proper disposal. 2. Repeat the extraction with fresh 5-mL portions of the DithiVer solution (discarding the bottom layer each time) until the bottom layer shows a pure dark green color for three successive extracts. Extractions can be repeated several times without appreciably affecting the amount of cadmium in the sample. 3. Extract the solution with several 2- or 3-mL portions of pure chloroform to remove any remaining DithiVer, collecting the bottom layer each time for proper disposal. 4. Continue with step 5 of the procedure. 5. In step 8, substitute 28.5 ml of DithiVer solution for the 30 ml. 6. Continue with step 9 of the procedure. Page 4 of 8

Table 63 Substances that do not interfere Aluminum Antimony Arsenic Calcium Chromium Cobalt Iron Lead Magnesium Manganese Nickel Tin Zinc Sample collection, preservation and storage Collect samples in an acid-washed glass or plastic containers. Adjust the ph to 2 or less with nitric acid (about 2 ml per liter). Store preserved samples up to six months at room temperature. Adjust the ph to 2.5 with 5.0 N sodium hydroxide before analysis. Correct the test result for volume additions. Dithiver solution preparation and storage Accuracy check Store DithiVer Powder Pillows away from light and heat. A convenient way to prepare this solution is to add the contents of 16 DithiVer Metals Reagent Powder Pillows to a 500-mL bottle of chloroform and invert several times until well mixed (carrier powder may not dissolve completely). Store dithizone solution in an amber glass bottle. This solution is stable for 24 hours. Required for accuracy check: Voluette Ampule Standard, 25-mg/L Cd TenSette Pipet, 0.1 1.0 ml and tips 1. After reading test results, leave the sample cell (unspiked sample) in the instrument. 2. Select Options>More>Standard Additions from the instrument menu. 3. Accept the default values for standard concentration, sample volume, and spike volumes. After the values are accepted, the unspiked sample reading will appear in the top row. See the user manual for more information. 4. Open the standard solution ampule. 5. Use the TenSette Pipet to add 0.1 ml, 0.2 ml, and 0.3 ml of standard, respectively to three 250-mL samples and mix each thoroughly. 6. Follow the Dithizone method with powder pillows test procedure for each of the spiked samples, starting with the 0.1 ml sample spike. Measure each of the spiked samples in the instrument. 7. Select GRAPH to view the results. Select IDEAL LINE (or best-fit) to compare the standard addition results to the theoretical 100% recovery. Standard Solution Method Required for accuracy check: Standard Solution, 100-mg/L Cd. Deionized water 100-mL Volumetric flask Page 5 of 8

Method performance Class A volumetric pipet and bulb 1. Prepare a 5.0-mg/L cadmium standard solution: a. Pipet 5.00 ml of Standard Solution, 100-mg/L Cd, into a 100-mL volumetric flask. b. Dilute to the mark with deionized water. Prepare this solution daily. 2. Pipet 2.00 ml of the 5.0-mg/L Standard Solution into 248 ml of deionized water in a 500-mL separatory funnel. This is a 40-µg/L cadmium solution. Perform Dithizone method with powder pillows on this solution beginning with step 3 of the procedure. 3. To adjust the calibration curve using the reading obtained with the standard solution, elect Options>More>Standard Adjust from the instrument menu. 4. Turn on the Standard Adjust feature and accept the shown concentration. If an alternate concentration is used, enter the concentration and adjust the curve to that value. Program Summary of method Standard The dithizone method is designed for the determination of cadmium in water and wastewater. The DithiVer Metals Reagent is a stable powder form of dithizone. ions in basic solution react with dithizone to form a pink to red cadmium-dithizonate complex, which is extracted with chloroform. Test results are measured at 515 nm. Pollution prevention and waste management Both chloroform (D022) and cyanide (D003) solutions are regulated as hazardous wastes by the Federal RCRA. Do not pour these solutions down the drain. Chloroform solutions and the cotton plug used in the delivery tube of the separatory funnel should be collected for disposal with laboratory solvent waste. Collect the cyanide solution as a reactive waste. Be sure that cyanide solutions are stored in a caustic solution with a ph >11 to prevent potential release of hydrogen cyanide gas. See the current MSDS for disposal information. Consumables and replacement items Precision 95% Confidence Limits of Distribution Sensitivity Concentration change per 0.010 Abs change 60 40.0 µg/l Cd 39.3 40.7 µg/l Cd 0.73 µg/l Required reagents Description Quantity/Test Unit Catalog number Reagent Set 100/pkg 2242200 Includes:(1) 14202-99, (1) 14458-17, (1) 12616-99, (1) 767-14, (4) 2180-49, (1) 2572-01 Buffer Powder Pillows, citrate 1 100/pkg 1420299 Chloroform, ACS 40 ml 4 L 1445817 DithiVer Metals Reagent Powder Pillows 1 100/pkg 1261699 Potassium Cyanide 0.1 g 125 g 76714 Sodium Hydroxide Solution, 50% 20 ml 500 ml 218049 Page 6 of 8

Required reagents (continued) Description Quantity/Test Unit Catalog number Cotton Balls, absorbent 1 100/pkg 257201 Required apparatus Description Quantity Unit Catalog number Clippers, for opening powder pillows 1 each 96800 Cylinder, graduated, 25-mL 1 each 50840 Cylinder, graduated, 250-mL 1 each 50846 Cylinder, graduated, mixing, 50-mL 1 each 189641 Funnel, separatory, 500-mL 1 each 52049 Sample cell, 25 ml square, matched pair with cap 2 2/pkg 2612602 Spoon, measuring, 0.1-g 1 each 51100 Support Ring, 4" 1 each 58001 Support Ring Stand, 5" x 8" base 1 each 56300 Recommended standards Description Unit Catalog number Standard Solution, 100-mg/L Cd 100 ml 1402442 Chloroform, ACS 500 ml 1445849 Hydrochloric Acid Solution, 6.0 N 500 ml 88449 Sodium Hydroxide Standard Solution, 5.0 N 100 ml MDB 245032 Sodium Hydroxide Standard Solution, 5.0 N 59 ml SCDB 245026 Water, deionized 4 L 27256 Page 7 of 8

Optional reagents and apparatus Description Unit Catalog number Cylinder, graduated, 5-mL each 50837 Filter Discs, glass, 47 mm 100/pkg 253000 Filter Holder, glass, for 47-mm filter each 234000 Flask, Erlenmeyer, 500-mL each 50549 Flask, filtering, 500-mL each 54649 Flask, volumetric, Class A, 100-mL each 1457442 Flask, volumetric, Class A, 250-mL each 1457446 Flask, volumetric, Class A, 1000-mL each 1457453 Gloves, chemical resistant, size 9 to 9.5 1 pair 2410104 Goggles, safety, vented each 2550700 Hot Plate, 3½-in. diameter, 120 VAC, 50/60 Hz each 1206701 ph Paper, ph 1.0 to 11.0 5 rolls/pkg 39133 Pipet Filler, safety bulb each 1465100 Pipet, serological, 2-mL each 53236 Pipet, TenSette, 0.1 to 1.0 ml each 1970001 Pipet Tips, for TenSette Pipet 1970001 50/pkg 2185696 Pipet Tips, for TenSette Pipet 1970001 1000/pkg 2185628 Pipet, volumetric, 2.00-mL, Class A each 1451536 Pipet, volumetric, 3.00-mL, Class A each 1451503 Pipet, volumetric, 6.00-mL, Class A each 1451506 Pipet, volumetric, 8.00-mL, Class A each 1451508 Pipet, volumetric, 9.00-mL, Class A each 1451509 Pipet, volumetric, 10.00-mL, Class A each 1451538 Pipet, volumetric, 20.00-mL, Class A each 1451520 Tongs, crucible, 9-inch each 56900 1 Other sizes available. FOR TECHNICAL ASSISTANCE, PRICE INFORMATION AND ORDERING: In the U.S.A. Call toll-free 800-227-4224 Outside the U.S.A. Contact the HACH office or distributor serving you. On the Worldwide Web www.hach.com; E-mail techhelp@hach.com HACH COMPANY WORLD HEADQUARTERS Telephone: (970) 669-3050 FAX: (970) 669-2932 Hach Company, 2007, 2010, 2012. All rights reserved. Printed in the U.S.A. Edition 7