PART 1- GENERAL. A. This section includes the following gymnasium equipment:

SECTION ORCHESTRA PIT FILLER

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Bus Facility

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Trex Commercial Products page Metal Railing

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION AWNINGS

SECTION ORNAMENTAL ALUMINUM RAILING

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

Bryan County Middle/High Renovation SECTION TELESCOPING STANDS

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH GLASS INFILLS

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

Section PANEL SIGNAGE

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

STRUCTURAL STEEL FRAMING

The Kodiak 3200 Seating System by Royal Stewart Ltd.:

SECTION ORNAMENTAL ALUMINUM RAILING

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION MECHANICALLY ASSISTED MOBILE STORAGE SHELVING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Soundmaster & Modernfold TECHNICAL DATA

LINEAR METAL CEILINGS Section

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

1. Fence and gate posts, rails, and fittings. 2. Chain-link fabric, reinforcements, and attachments.

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

SECTION ACCORDION FOLDING PARTITIONS

SECTION HIGH-SECURITY CHAIN LINK FENCES AND GATES

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION OUTLET, PULL, AND JUNCTION BOXES

DIVISION 2 - SITE WORK

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

A. Glass Railing Series with Mushroom Top Cap with Glass Panel Infill.

. SECTION HANGERS AND SUPPORTS

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

Construction Standards PAGE

SECTION ACOUSTICAL PANEL CEILINGS

Acousti-Seal 933E. Operable Partitions (10650)

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

A. Access doors and frames are part of an access door and frame allowance.

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION HANGERS AND SUPPORTS FOR PLUMBING

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

A. Product Data: For each type of cold-formed steel framing product and accessory.

SECTION COLD-FORMED METAL FRAMING

SECTION MISCELLANEOUS METALS

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

On-Call General Contractor Specifications University of Maryland College Park June 2013

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

DECORATIVE METAL RAILINGS

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

SECTION ROOF EDGE SAFETY RAILING SYSTEM

SECTION METAL DOORS & FRAMES

SECTION METAL STAIRS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION METAL STAIRS

UNISTRUT CORPORATION GENERAL NOTES 1. THIS UNISTRUT SUPPORT SYSTEM IS DESIGNED TO SUPPORT A MAXIMUM UNIFORM LOAD OF PSF.

1. Hangers and supports for electrical equipment and systems.

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION (06415) - PLASTIC COUNTERTOPS

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

B. Shop Drawings: Include plans, elevations, sections, details, and attachments.

EXECUTION REQUIREMENTS

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION ORNAMENTAL ALUMINUM RAILINGS PART 1 - GENERAL 1.01 SUMMARY

Transcription:

SECTION.00 - GYMNASIUM EQUIPMENT PART - GENERAL 0 0. SUMMARY A. This Section includes the following gymnasium equipment that is being supplied and installed by the Owner. The Contractor shall provide the electrical connections associated with this equipment and in some cases install specific components (Inserts) into the project to accept the equipment:. Basketball backstop equipment. (Forward Fold and Side Fold). Volleyball equipment.. Divider curtains.. Scoreboard. Gymnasium control center.. Shot Timers. Safety pads / mats.. Telescoping gymnasium bleachers. B. Related Sections include the following:. Division 0 Section Alternates, for Alternates related to this Section. Division 0 Section "Cast-in-Place Concrete" for installation of floor insert sleeves to be cast in concrete slabs and footings.. Division Sections for electrical service for motor operators, controls, and other powered devices for motorized gymnasium equipment.. DEFINITIONS A. NFHS: The National Federation of State High School Associations. B. USAV: USA Volleyball.. PERFORMANCE REQUIREMENTS A. Seismic Performance: Provide basketball backboards capable of withstanding the effects of earthquake motions determined according to ASCE, "Minimum Design Loads for Buildings and Other Structures": Section, "Earthquake Loads." 0. SUBMITTALS A. Product Data: For each type of product indicated.. If applicable, include assembly, disassembly, and storage instructions for removable equipment.. Motors: Show nameplate data, ratings, characteristics, and mounting arrangements. B. Coordination Drawings: Court layout plans, drawn to scale, and coordinating floor inserts, game lines, and markers applied to finished flooring. GYMNASIUM EQUIPMENT.00 -

.. QUALITY ASSURANCE A. Source Limitations: Obtain each type of gymnasium equipment through one source from a single manufacturer. B. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 0, Article 00, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. 0. PROJECT CONDITIONS A. Environmental Limitations: Do not install gymnasium equipment until spaces are enclosed and weatherproof, wet work in spaces is complete and dry, and ambient temperature and humidity conditions are maintained at the levels indicated for Project when occupied for its intended use. B. Field Measurements: Verify position and elevation of floor inserts and layout for gymnasium equipment.. COORDINATION A. Coordinate installation of floor inserts with structural floors and finish flooring installation and with court layout and game lines and markers on finish flooring. B. Coordinate layout and installation of overhead-supported gymnasium equipment and suspension system components with other construction including light fixtures, HVAC equipment, fire-suppression-system components, and partition assemblies. PART - PRODUCTS 0 0. MATERIALS A. Aluminum: Alloy and temper recommended by manufacturer for type of use and finish indicated.. Extruded Bars, Profiles, and Tubes: ASTM B (ASTM B M).. Cast Aluminum: ASTM B.. Flat Sheet: ASTM B 0 (ASTM B 0M). B. Steel: Comply with the following:. Steel Plates, Shapes, and Bars: ASTM A /A M.. Steel Tubing: ASTM A 00 or ASTM A, cold formed.. Steel Sheet: ASTM A 0/A 0M. C. Support Cable: /-inch- (-mm-) diameter, x galvanized steel aircraft cable with a breaking strength of 000 lb ( kg)]. Provide fittings complying with cable manufacturer's written instructions for size, number, and method of installation. GYMNASIUM EQUIPMENT.00 -

0 D. Support Chain and Fittings: Grade 0 hardened alloy steel chain rated for overhead lifting, ASTM A /A M, with commercial-quality, steel connectors and hangars. E. Castings and Hangers: Malleable iron, ASTM A /A M, grade required for structural loading. F. Softwood Plywood: DOC PS, exterior. G. Medium-Density Fiberboard: ANSI A0. H. Equipment Wall-Mounting Board: Wood, transparent finish, size, and quantity as required to mount gymnasium equipment according to manufacturer's written instructions. I. Anchors, Fasteners, Fittings and Hardware: Manufacturer's standard corrosion-resistant units; concealed. J. Grout: Nonshrink, nonmetallic, premixed, factory-packaged, nonstaining, noncorrosive, nongaseous grout complying with ASTM C 0 with minimum strength recommended in writing by gymnasium equipment manufacturer. 0 0. BASKETBALL EQUIPMENT A. The following gymnasium equipment shall be supplied and installed by Degler-Whiting, Inc. (0-- ). Unless noted otherwise, the following equipment is manufactured by the Porter Athletic Equipment Company. The Contractor shall provide the necessary electrical connections and controls for each of the following equipment and install the associated inserts for specific equipment into this project to provide a complete working system:. Overhead-Supported Basketball Backstop: a. Model 0000 Forward Fold Backstop b. Model 0000 Side Fold Backstop. Volleyball Package:-XX Powr-Rib II. (Install floor inserts and cover plates). Gymnasium Divider Curtains: Model 0000 Center-roll divider.. Basketball Scoreboard by Fair-Play: Model BB-0-. Gymnasium Control Center: Model 0-000 Powr-Touch... Shot Timer by Fair Play: Model ST-0-. B. General: Provide equipment complying with requirements in NFHS's "NFHS Basketball Rule Book." C. Protruding fasteners or exposed bolt heads on front face of backboards are not permitted.. VOLLEYBALL EQUIPMENT A. Floor Insert: The following floor inserts shall be supplied by the Owner. The contractor shall incorporate and install the following inserts:. Model #00 floor sleeves with cover plates for use with floating floor system. For pickleball courts.. Model #00 floor sleeves with cover plates for use with floating floor system. For volleyball courts. B. Post Standards will be provided by the Owner. GYMNASIUM EQUIPMENT.00 -

0. SAFETY PADS A. The safety wall pads are to be supplied and installed by Degler-Whiting, Inc. (0) - B. Basis-of-Design Product: Mancino Manufacturing Company; Model #0-00 wall padding panels with lettering as detailed on the drawings. C. Wall Safety Pads (Wall Mats): Padded wall wainscot panels designed to be attached in a continuous row; each panel section consisting of fill laminated to backer board with visible surfaces fully covered by seamless fabric covering, free of sag and wrinkles and firmly attached to back of backer board.. Backer Board: / thick composite board.. Fill: Multiple-impact-resistant fire retardant polyurethane foam not less than thick.. Size: As indicated.. Number of Panel Sections: as indicated.. Installation Method: Padding panels are to be mounted to furring strips attached to the wall at the top, middle and bottom of the padding. Ends of padding runs shall include vertical furring strips. All cut-outs in the padding are to be supported by furring strips. Furring strips at top, ends and cut outs are to be wrapped in vinyl matching the padding.. Fabric Covering Color(s): To be selected from the manufacturer s full range.. Graphics: Custom lettering as indicated. Font type as selected. 0. TELESCOPIC BLEAHERS A. Telescopic Gymnasium Bleachers: The owner will be providing and installing Closed deck, telescopic bleachers as manufactured by Interkal. The bleachers shall be attached to the new wall as indicated. The Contractor shall comply with the following requirements:. Electrical Power Source Requirements: A ½ HP, 0 volt -phase motor shall be included with the bleacher system. PART - EXECUTION 0. EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for play court layout, alignment of mounting substrates, installation tolerances, operational clearances, accurate locations of connections to building electrical system, and other conditions affecting performance.. Verify critical dimensions.. Examine supporting structure.. Examine wall assemblies, where reinforced to receive anchors and fasteners, to verify that locations of concealed reinforcements have been clearly marked. Locate reinforcements and mark locations.. Proceed with installation only after unsatisfactory conditions have been corrected. GYMNASIUM EQUIPMENT.00 -

0 0. INSTALLATION, GENERAL A. General: Comply with manufacturer's written installation instructions and competition rules indicated for each type of gymnasium equipment. Complete equipment field assembly, where required. B. Unless otherwise indicated, install gymnasium equipment after other finishing operations, including painting, have been completed. C. Permanently Placed Gymnasium Equipment and Components: Rigid, level, plumb, square, and true; anchored securely to supporting structure; positioned at locations and elevations indicated on Shop Drawings; in proper relation to adjacent construction; and aligned with court layout.. Floor Insert Location: Coordinate location with application of game lines and markers.. Floor Insert Elevation: Coordinate installed heights of floor insert with installation of finish flooring and type of floor plate.. Operating Gymnasium Equipment: Verify clearances for movable components of gymnasium equipment throughout entire range of operation and for access to operating components. D. Floor Insert Setting: Position sleeve in oversized, recessed voids in concrete slabs. Clean voids of debris. Fill void around sleeves with grout, mixed and placed to comply with grout manufacturer's written instructions. Protect portion of sleeve above subfloor from splatter. Verify that sleeves are set plumb, aligned, and at correct height and spacing; hold in position during placement and finishing operations until grout is sufficiently cured. Set insert so top surface of completed unit is flush with finished flooring surface. E. Safety Wall Pads and Mats: Unless indicated otherwise, mount with bottom edge at above finished floor.. Cut wall pads around all electrical receptacle and switches. Coordinate with Divisions. F. Anchoring to In-Place Construction: Use anchors and fasteners where necessary for securing built-in and permanently placed gymnasium equipment to structural support and for properly transferring load to inplace construction. 0. ADJUSTING A. Adjust movable components of gymnasium equipment to operate safely, smoothly, easily, and quietly, free from binding, warp, distortion, nonalignment, misplacement, disruption, or malfunction, throughout entire operational range. Lubricate hardware and moving parts.. CLEANING A. After completing gymnasium equipment installation, inspect components. Remove spots, dirt, and debris and touch up damaged shop-applied finishes according to manufacturer's written instructions. B. Replace gymnasium equipment and finishes that cannot be cleaned and repaired, in a manner approved by Architect, before time of Substantial Completion. GYMNASIUM EQUIPMENT.00 -

. DEMONSTRATION A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain gymnasium equipment. Refer to Division Section "Demonstration and Training." END OF SECTION.00 GYMNASIUM EQUIPMENT.00 -