F I R E M A N A G E M E N T P R O D U C T S DEFLECTION

Similar documents
F I R E M A N A G E M E N T P R O D U C T S DEFLECTION

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

FIRE MANAGEMENT PRODUCTS FAS Track 1000 DDA (Deflection Drift Angle ) HOTROD Type-X

Solutions for. Solutions for Fire-stopping. Deflection MADE IN AMERICA

BlazeFrame product catalog STRONGER. clarkdietrich.com/blazeframe

UL Design System HW-D-1012 continued

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Manufacturing Facilities City of Industry, CA Denver, CO Ft. Worth, TX Pittsburg, CA PRO-X HEADER

Firestopping Submittal Package

Expanding Your Solutions. ProX Header Rough Opening System

SECTION NON--STRUCTURAL METAL FRAMING

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

SLOTTED STUD WIND-LOAD & NON-LOAD BEARING DEFLECTION WALL SYSTEM. U.L. FIRE RATED Head-of-Wall Joint Systems

The System U.S. Patent No. 5,913,788

I-STUD Shaftwall System

CEMCO is Proud to Introduce an Innovative Steel Floor Joist System

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

System No. HW-D-0119

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

SECTION GYPSUM BOARD ASSEMBLIES

2012 & 2015 International Building Code. Section Section Section Section Section Section 713.4

2012 & 2015 International Building Code. Section Section Section 713.4

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

SECTION STRUCTURAL INSULATED PANELS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Cavity ShAftwall System

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

FIRESTOPPING & SMOKE SEALS

I-STUD Shaftwall System

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631

ICC-ES Evaluation Report

SECTION GYPSUM BOARD

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Construction Standards PAGE

SECTION SELF-ADHERING SHEET FLASHING

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

EDGEWATER, FLORIDA JUNE 14, 2010

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION GYPSUM BOARD

SECTION NON-STRUCTURAL METAL FRAMING

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, EVALUATION SERVICES EVALUATION CRITERIA FOR STEEL ROOF DECK.

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

Alply CLASSIC WALL Architectural Insulated Panel Wall System

FIRESTOP SUBMITTAL PACKAGE

SECTION NON-STRUCTURAL METAL FRAMING

SECTION Fiber Reinforced Stucco 1

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

A. Product Data: For each type of cold-formed steel framing product and accessory.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

SECTION GYPSUM BOARD

BEARING METAL STUD FRAMING

SECTION COMPOSITE METAL DECKING

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

System No. HW-D-0548

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

GUIDE SPECIFICATION: DUCT LINER

EDGEWATER, FLORIDA JUNE 14, 2010

Shaftwall and Area Separation Wall Systems.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

SECTION GYPSUM BOARD

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

SECTION GYPSUM BOARD PART 1 - GENERAL

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ICC-ES Evaluation Report Reissued February 1, 2011 This report is subject to re-examination in one year.

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

St. Monica Food Pantry

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

GYPSUM BOARD

SECTION COLD-FORMED METAL FRAMING

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

PRODUCT DATA SHEET Metacaulk BOX GUARD Classified under Wall Opening Protective Material as found in UL's Fire Resistance Directory

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Gold Bond BRAND Gypsum Sheathing

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

Transcription:

F I R E M A N A G E M E N T P R O D U C T S DEFLECTION FIRE FIRE AIR AIR SOUND SOUND w w w. c e m c o s t e e l. c o m

FAS TRACK S ENVIRONMENTAL BENEFITS AND LEED CONTRIBUTIONS FAS Track represents an environmental advancement for interior partition construction. Its resilient intumescent layer of Blaze Seal makes it a one-piece solution to acoustical and fire resistive head assemblies. FAS Track s partition head assembly eliminates most bridging, elastomeric sealants, mineral wool, and the need to cut drywall to fit the flutes of decking. FAS Track reduces scraps and waste and often does not require any sealant to be applied to the head of wall joint. Resources are saved, and indoor air quality is improved. FAS Track contributes to a number of LEED credits in the 2009 New Construction, Core and Shell, Commercial Interiors, and Schools rating systems. RESOURCE CONSERVATION: Because even very short pieces of FAS Track are used in construction, very little is wasted. Scraps as small as 16 inches are often retained. The metal portion of smaller scraps can be recycled, once the BlazeSeal is peeled off by hand. For projects with high targets for MR 2 Construction Waste Management, this method of recycling FAS Track scraps will contribute to this credit. MR CREDIT 4 RECYCLED CONTENT: Like all of CEMCO s framing products, FAS Track contributes 32.7% recycled content to this credit. IEQ 3.2 INDOOR AIR QUALITY MANAGEMENT PLAN BEFORE OCCUPANCY: If the Air Testing option is selected by the project team, FAS Track is a valuable player in achieving this credit. FAS Track eliminates the need for spray-applied smoke seal and elastomeric fire sealant. It also can take the place of acoustical sealant in some assemblies. With no solvents and very low VOC content, FAS Track significantly reduces indoor air pollution. The Air Testing option is difficult to achieve, and every bit of indoor pollution that FAS Track eliminates from the project increases the chances of success. IEQ 4.1 LOW-EMITTING MATERIALS ADHESIVES AND SEALANTS: FAS Track s intumescent fire-resistive seal is a solid, factory-applied layer, so it is not required to comply with the Adhesives and Sealants VOC limits. Moreover, because BlazeSeal provides all the fire protection required for many partitions, no spray-applied smoke seals or elastomeric fire-resistive sealants are required, so their VOC contributions are eliminated. IEQ 4.6 LOW-EMITTING MATERIALS CEILING AND WALL SYSTEMS (LEED FOR SCHOOLS): This credit does not apply to FAS Track. Only the gypsum board and the wall coverings are required to be tested. IEQ 9 ENHANCED ACOUSTICAL PERFORMANCE (LEED FOR SCHOOLS): FAS Track improves the Sound Transmission Class (STC) of partitions, and can even eliminate the need for acoustical sealant at the head of partitions. Its resilient BlazeSeal layer helps damp sound transmission of partitions around core learning spaces and can help achieve this credit. For other LEED credit contributions, see HYPERLINK http:// and click LEED Certification. If you have any questions, concerns, or clarifications, please contact our Technical Services Department at (800) 416-2278 or HYPERLINK http://.

TA BLE TABLE OF OF CONTENTS FAS Track About FAS Track...................................................................... 2-6 FAS Track 1-1/4" Deflection Assemblies..................................................... 7-10 FAS Track DL2 2" Deflection Assemblies.................................................. 11-13 FAS Strap About FAS Strap..................................................................... 14-15 FAS Shaft FAS Shaft 1-1/4" Deflection Assemblies................................................... 17-19... FAS Shaft 2" Deflection Assemblies......................................................20 FAS Track FAS Track 500...................................................................... 21-22 Firestik Firestik............................................................................ 23-24 CEMCO 925-473-9340 Customer Service CEMCO 925-473-9340 Customer Service CEMCO 303-572-3626 Customer Service Marino\Ware 219-378-7100 Mike Fenbert www.marinoware.com Marino\Ware 800-627-8199 Gerry Compton www.marinoware.com CEMCO 800-775-2362 Customer Service CEMCO 817-568-1525 Customer Service Marino\Ware 800-504-8199 Bill Mayne www.marinoware.com CEMCO 925-473-9340 Customer Service 1 1

TM FAS Track is an exclusive Cemco Fire Management Product approach to Firestopping dynamic joints allowing up to two inches of unencumbered movement in a fire rated partition. The flexibility of the FAS Track product is used to protect dynamic joints in cold formed steel/gypsum walls. The unique profile provides superior movement capabilities while eliminating any additional requirements of fire caulk, fire resistant sprays, drywall rips, or contour drywall cuts around fluted decks. The simple single source product allows 100% unencumbered movement while experiencing no fatigue to the fire resistance during the life of the assembly. CODE COMPLIANCE FAS Track meets all current building codes and its unique profile design provides industry solutions for meeting deflection requirements where other materials or systems are restricted by design, compressibility, elasticity, or bond strength characteristics. FAS Track has no restrictions providing 100% unencumbered movement. FAS Track has been tested for compliance with Section 713.3 of the 2006 IBC and 2007 CBC and is listed with UL Underwriters Laboratories in accordance with: UL 2079: Tests for Fire Resistance of Building Joint Systems. ASTM E 1966: Standard Test Method of Fire Tests of Firestop Systems. ULC S115-M95: Standard Method of Fire Tests of Firestop Systems. SEISMIC REQUIREMENTS Fas Track is approved for Class III cycling requirements, 500 cycles at 30 cycles per minute, meeting seismic building codes requirements. The class III movement provides design advantages over mastic reliant systems which are currently limited to level II (wind sway) capabilities of 500 cycles at 10 cycles per minute. AIR LEAKAGE RATING Air leakage tests conducted for compliance with Section 713.6 of the 2006 IBC and 2007 CBC are witnessed by UL on conditions using FAS Track as the joint treatment established L-Ratings of less than 1 CFM per lineal foot. Any rating below 1 CFM is also considered the best possible L-Rating. This is achieved with the FAS Track profile external groove; which provides a consistent seal against the drywall. SOUND CONTROL Sound can be passed through vibrations of metal to metal connections. The FAS Track profile provides two unique features to control sound transmissions. First, by incorporating intumescent tape around the corner of the track it works as a gasket when installed against a solid deck. Second, the external groove provides a tight seal against drywall blocking out sound and air transmissions. No additional caulking required on the top head of wall track. SOUND TESTING Sound Testing was performed at Western Electro-Acoustic Laboratory in Southern California (Test# TL08-696). The purpose of the sound testing was to see if the FAS Track installed without acoustic caulking would perform as well as a standard track with acoustic caulking. The test specimen was a wall assembly constructed from metal studs, resilient channel and type X gypsum board. The resilient channel was installed on one side only. The metal studs were 3-5/8 inch (92 mm) CEMCO 20 gauge spaced at 24 inches (609 mm) O.C. The siltrack was 3-5/8 inch (92 mm) CEMCO 20 gauge metal. The head track was 3-5/8 inch (92 mm) CEMCO FAS Track 20 gauge metal. The sill and vertical edges had acoustic caulking applied but the top edge along the FAS Track was left open with no acoustic caulking. This test rendered an STC rating of 52. This is the same STC rating of a wall with acoustic caulking across the top track. Therefore, in essence, the FAS Track does truly offer the same sound rating as acoustic caulking. 2 800.775.2362

There is no fire resistant spray required over the mineral wool because of the expansive qualities of Intumescent. [Test photo taken after the hose steam test] Seismic listing and ratings are based on Class III movement. Provides quality assurance of factory applied fire resistant material. Unaffected by wet, freezing, humid conditions, or hot (below 300 F). Best possible L-Rating of less than 1 CFM. STC capabilities in the same range of acoustic caulks. FAS TRACK ADVANTAGES Superior unencumbered movement of up to 2 overall. Eliminates reliance of adhesion and bond strength of fire caulk. Eliminates the requirement of fire resistant sprays over mineral wool on fluted deck assemblies. Eliminates the worry of adhesive, cohesive, and substrate failures of using fire caulking. No fatigue to the firestopping for the life of the assembly. By eliminating the installation of fire caulking/fire resistant sprays the project is done in less time. Eliminating the installation of fire caulking/ fire resistant sprays saves time and money of clean up, making FAS Track a clean choice. Provides UL Fire Rated assemblies for one, two, and three hour walls with the same track profile. Product identifications and approval recognition every 48 for easy inspection. Reduces inspection time. Cured intumescent tape makes product odor free and effective immediately. By reducing overall labor construction unit costs are lower. Architectural features are increased by eliminating the need of fire caulking. The architectural feature of the Floating Ceiling can be achieved while still providing a fire rated wall. The proprietary FAS Track design provides fire stopping protection exceeding the stringent UL 2079 test standards for Head of Wall (HOW) joints in fire rated partitions. Design benefits of the combination of intumescent and metal slotted track profile provides superior movement and protection of fire resistant joint. 3

FAS FATRACK S T R - APROVIDES CK 1-1/4 TOTAL MOVEMENT PROFILE DESCRIPTION External groove located above the deflection slots provides an air tight assembly when in contact with the drywall. The external groove also provides increased sound ratings, as it reduces sound vibrations. 1 4 " The contoured corner of the track allows the intumescent to fit into the track profile without damage during handling or impeding the head of wall assembly. 89 The track profile allows the intumescent to seal against the leg as well as the top corner of the track, this allows the intumescent to expand both up and out at the same time. 89 A A 3 1 4 " DETAIL A SCALE 2 : 1 90 1 8 " 1-1/2 x 1/4 slots 1 on center for deflection. INTUMESCENT Cured 2mm thick material factory adhered to FAS Track profile. R 1 8 " 1 1 2 " 1" 120" Outer layer of intumescent has a polyester film to protect from water, UV, dirt and damages. Expands at temperatures in excess of 300 Fahrenheit. Becomes a hard char expanding in excess of 35 times its original size. Fills HOW joint creating seal preventing passage of flame, heat, and smoke through joint. Cured and odor free providing immediate protection. Patent No. US 7, 617, 643 B2 Track Member Width Length Gauge (mils) 2-1/2, 3-5/8, 4, 6, and 8 10 0 20, 18, 16 and 14 GA (33, 43, 54, & 68 mil) Active ingredients protect either 1, 2 or 3 hour fire rated joints. In a pan deck assembly the intumescent expands over the mineral wool creating a seal and eliminating the need for fire resistant sprays. FAS TRACK DL PROFILE SPECIFICATIONS 1 4 " Hot dipped galvanized steel complying with ASTM A653 and ASTM A1003 Structural Grade 50 Type H for Grade 33 Type H for a minimum coating of G-60 and complies with ASTM C645. (G) 89 1 1 8 " Track member width 2-1/2, 3-5/8, 4, 6, and 8. Gauge (mils) 20, 18, 16, and 14 GA (33, 43, 54, and 68 mil). 1 1 8 " 89 2 1 2 " A DETAIL A SCALE 2 : 1 1 8 " Intumescent tape 2mm. Length 10 0 standard custom sizes available. Deep leg track with 2-1/2" legs. (Z) (G)=.033 to.068 mils (Z) = 2-1/2" to 8" The external groove also provides increased sound ratings,as it reduces sound vibrations. The external groove provides an air tight assembly when it contact with drywall. 10' 4 800.775.2362

FAS TRACK DEFLECTION CAPABILITIES OF UL LISTED DYNAMIC ASSEMBLIES Approved deflection of firestop materials protecting dynamic Head of Wall (HOW) joints listed through UL are based on two major factors. The first, Nominal Joint Width refers to the installed gap distance defined by the joint between the top of wall/wall sheathing and overhead structure. The second, Movement capabilities refers to the maximum percentage of the nominal joint width that joint materials can deflect without compromise or failure at a given cycle rate based on three levels. Level I: 1 cycle/min for total of 500 cycles (Thermal) Level II: 10 cycles/min for total of 500 cycles (Wind Sway) Level III: 30 cycles/min for total of 500 cycles (Seismic) The following illustration displays deflection capabilities and required nominal joint widths using the majority of sealant type joint systems typically limited to class II movement. These systems being reliant upon compressibility, elasticity, and or bond strength of fill, void, or cavity materials (mineral wool and fire caulk/spray) are restricted to common UL ratings of +/- 25% movement capabilities: NOMINAL 25% JOINT WIDTH 25% COMPRESSION 25% EXTENSION DEFLECTION = COMPRESS. + EXT. COMPRESSION ONLY 1/2 1/8 1/8 1/4 1/8 1 1/4 1/4 1/2 1/4 2 1/2 1/2 1 1/2 4 1 1 2 1 In comparison, UL listed dynamic HOW assemblies utilizing FAS Track profiles are provided 100% movement capabilities during compression or extension for class I, II, or III movement. The following illustration shows deflection capabilities provided using FAS Track as the HOW joint fire stop protection: NOMINAL JOINT WIDTH 5/8" (FAS Track) EXAMPLE FAS TRACK UL LISTING System No. HW-D-0515 Assembly Rating 1 and 2 HR (See Item 2) L Rating at Ambient Less Than 1 CFM/Lin ft L Rating at 400 F Less Than 1 CFM/Lin ft Nominal Joint Width 1/2 in. and 1 in. (See Item 3) Class II and III Movement Capabilities 100% Compression & Extension 100% COMPRESSION 100% EXTENSION DEFLECTION = COMPRESS. + EXT. COMPRESSION ONLY 5/8" 5/8" 1-1/4" 1-1/4" The proprietary design and use of FAS Track enables assemblies to be installed with smaller nominal gap joints and achieve superior movement. The unencumbered movement allows for unequal compression and extension designs when overall deflection requirements are within parameters of the deflection limits of individual profiles. TYPICAL FAILURES OF JOINTS USING SEALANT ADHESIVE FAILURE COHESIVE FAILURE SUBSTRATE FAILURE SEALANT PULLS AWAY FROM SUBSTRATE SEALANT TEARS WHEN EXTENDED STRESS FROM SEALANT CAUSES SUBSTRATE FAILURE AVOID THREE SIDED ADHESION AVOID DISPLACEMENT FROM COMPRESSION SEALANT BONDS TO TRACK SURFACE AND MAY BECOME BEARING SEALANT TEARS OR SUBSTRATE DAMAGE WITH JOINT MOVEMENT SEALANT UPON INSTALLATION SEALANT DISPLACED BY COMPRESSION OF JOINT 5

FAS TRACK SMOKE BARRIERS/L-RATING UL provides an optional L-Rating which can be measured and assigned to individual assembly penetrations or joints. The L-Rating simply defined for a joint is a measurement of the air leakage rate through a fire stop system or fire-resistive joint system without fire exposure, tested under a differential pressure of 0.30 inches water column (75 Pa) at both 75 and 400 degrees Fahrenheit.It is expressed as a volumetric flow rate in units of cfm/lft. Measurements taken of assemblies using either slotted or solid leg tracks and utilizing Fas Track HOW joint fire stop protection established L-Ratings for FAS Track. Tested severe condition assemblies were installed perpendicular to a 3 deep fluted pan deck having only a 4pcf mineral wool compressed 33% into the flute, no mastic covering per UL listed Fas Track assemblies, no insulation materials inside wall cavities or HOW gap, and cycled 500 times at level III (30 cycles/min) movement. IBC 2006 713.6 Fire-resistant joint systems in smoke barriers. Fire-resistant joint systems in smoke barriers shall be tested in accordance with the requirements of UL 2079 for air leakage. The air leakage rate of the joint shall not exceed 5.0 cfm per lineal foot (0.00775 m3/slm) of joint at.30 inch (7.47 Pa) of water for both the ambient temperature and elevated temperature tests. Results of UL L-Rating tests show assemblies utilizing FAS Track fire-resistive joint protection for up to level III movement achieve the lowest ratings possible for air leakage protection well below the IBC standard of 5 CFM/lft. INSTALLATION There are no special requirements needed to install FAS Track.The FAS Track is installed the same way you would install any standard top track. First select the appropriate width and gage to accommodate the desired wall assembly. The installation requires only positive attachment of power actuated friction fit, or mechanical fasteners. Attachment to flat concrete or pan deck use min. 1 power actuated fasteners and anchor at 24 O/C. Metal to metal use #8 framing screws at 24 max O/C. Install adjoining pieces butted in contact with each other. In unique structural conditions fasteners and spacing should be approved by Engineer of Record. For incidental gaps between FAS Track butt joints or gaps in the corner connections, use repair strips provided by manufacture. Intumescent tape is compatible with non solvent sealants, latex paint, tapping mud, fire proofing,and fire sealant MANUFACTURES RECOMMENDATIONS When using FAS Track with pan deck overhead, install in accordance with specifications of UL approved assemblies protection of flutes with fire proofing or mineral wool stuff only sprays are not required. Although FAS Track can be exposed to weather conditions it is recommended to store in a covered area. If intumescent tape has been damaged or pulled away from track, consult manufacture for repair protocol. All track end joints are to be installed tight to each other without gaps between pieces. Notify the IOR when FAS Track is being installed so that inspections can be coordinated during the framing inspection. If overhead concrete deck is uneven acoustic sealant may be used to fill gaps to protect against smoke and sound transfer. 6 FAS Track UL Numbers HW-D-0514, HW-D-0515, HW-D-0518, HW-D-0524, HW-D-0525, HW-D-0550 HW-D-0551, HW-D-0553, HW-D-0554, HW-D-0556, HW-D-0557, HW-D-0563. WW-S-0057,HW-D-0573, HW-D-0576, HW-D-0577, HW-D-0578, HW-D-0579 HW-D-0580, HW-D-0581, HW-D-0582, HW-D-0583, HW-D-0584, HW-D-0585 HW-D-0586, HW-D-0587, HW-D-0596, HW-D-0598, HW-D-0599, HW-D-0600 HW-D-0601, HW-D-0620, HW-D-0621, HW-D-0622, HW-D-0623, HW-D-0624 HW-D-0625, BW-S-0024, WW-S-0061, WW-D-0104, HW-D-0652, HW-D-0653 Please logon to for updates. 800.775.2362 7

FAS TRACK DETAILS - PROVIDES 1-1/4 MOVEMENT FAS TRACK CONCRETE SLAB FAS TRACK PERPENDICULAR TO FLUTED DECK S2 C HW-D-0515 HEAD OF WALL SYSTEM 2, FAS TRACK WITH CONCRETE SLAB 5/8 NOMINAL JOINT. 100% MOVEMENT 1 AND 2 HOUR FIRE RESISTANT ASSEMBLY S1 T UD HW-D-0518 HEAD OF WALL SYSTEM 1, FAS TRACK PERPENDICULAR UNDER FLUTED DECK. 5/8 NOMINAL JOINT. 100% MOVEMENT 2 HOUR FIRE RESISTANT ASSEMBLY FAST 2 FAST 2 FAS TRACK PARALLEL WITH FLUTED DECK 1-1/4" INCH MOVEMENT FAS TRACK CANTILEVER UNDER BEAM-REGULAR WALL 5/8" NOMINAL GAP S1 UD HW-D-0524 CONFIGURATION A - SYSTEM 1, PARALLEL TO FLUTE CENTERED UNDER FLUTED DECK 1 AND 2 HOUR FIRE RESISTANT ASSEMBLY HW-D-0600 CANTILEVER UNDER BEAM REGULAR WALL SYSTEM, 5/8 NOMINAL JOINT. 100% MOVEMENT 1 AND 2 HOUR FIRE RESISTANT ASSEMBLY FAST 2 7

FAS TRACK DETAILS FAS TRACK STAIRWELL BYPASS AT I- BEAM FAS TRACK CENTERED DIRECTLY UNDER BEAM MINERAL WOOL OR FIRE PROOFING HW-D-0551 STAIRWELL SLAB BY PASS @ I-BEAM 5/8 NOMINAL JOINT S9 UB HW-D-0551 HEAD OF WALL SYSTEM 9, CENTERED DIRECTLY UNDER BEAM. (SEE UL LISTING FOR WALL FIRE RATING) UL-2078 TEST STD. FAST 2 (SEE UL LISTING FOR WALL FIRE RATING) UL-2078 TEST STD. FAS TRACK CHASE WALL AT PAN DECK FAS TRACK CHASE WALL AT CONCRETE SLAB 5/8" S1 C T PD HW-D-0553 CHASE WALL SYSTEM 1, PERPENDICULAR TO FLUTE DECK. 5/8 NOMINAL JOINT, 100% MOVEMENT S2 C HW-D-0554 CHASE WALL AT CONCRETE SLAB. FAST 2 FAST 2 (SEE UL LISTING FOR WALL FIRE RATING) 8 800.775.2362

FAS TRACK DETAILS FAS TRACK PARALLEL TO I-BEAM FAS TRACK VERTICAL WALL TIE-IN TO CONCRETE COLIMN S1G FAST 2 TB HW-D-0556 HEAD OF WALL SYSTEM 1, PARALLEL TO BEAM ASSEMBLY. UNDER FLUTED DECK. 5/8 NOMINAL JOINT. 100% MOVEMENT WW-D-0104 VERTICAL WALL TIE-IN TO CONCRETE COLIMN FAS TRACK PERPENDICULAR I-BEAM PENETRATION FAS TRACK HEAD OF WALL SYSTEM AT STAIR WELL SLAB HW-D-0573 PERPINDICULAR I - BEAM PENETRATION 5/8 NOMINAL GAP/1 TOTAL MOVEMENT HW-D-0596 STAIR WELL BY-PASS 9

FAS TRACK DETAILS FAS TRACK BOTTOM OF WALL BW FAS TRACK PARALLEL TO FLUTE (A) BW-S-0024 BOTTOM OF WALL STATIC JOINT. HW-D-0620 PARALLEL TO FLUTED DECK/ DIRECT UNDER FLUTE JOINT SYSTEM: FOR 5/8 NOMINAL GAP: FAS TRACK / FAS TRACK DL FOR 1 NOMINAL GAP: FAS TRACK DL2 CONFIGURATION A FAS TRACK PARALLEL TO FLUTE (B) FAS TRACK STANDARD WALL CANTILEVER UNDER BEAM HW-D-0620- PARALLEL UNDER PAN DECK CONFIGURATION B GAP 5/8-1. 100% MOVEMENT HW-D-0652- CONFIGURATION C HEAD OF WALL SYSTEM. OFF CENTERED UNDER BEAM. 1 NOMINAL GAP, 100% MOVEMENT, 100% COMPRESSION, L-RATING LESS THAN 1CFM 2 HOUR FIRE RESISTANT ASSEMBLY. 10 800.775.2362

FAS TRACK DL2 - PROVIDES 2 TOTAL MOVEMENT CEMCO FAS TRACK DL2 CEMCO s FAS Track 2 will now accommodate 2 total movement. With FAS Track 2 you will get the same fire, air and sound protection you get with the standard FAS Track but with the ability to handle up to a full 2 (two inches) of 100% unencumbered movement. This new system has been fully tested with Underwriters Laboratories, and is currently listed in no less than 12 new UL fire-rated assemblies. INTUMESCENT Cured 2mm thick material factory adhered to FAS Track profile. Outer layer of intumescent has a polyester film to protect from water, UV, dirt and damages. Expands at temperatures in excess of 300 Fahrenheit. Becomes a hard char expanding in excess of 35 times its original size. Fills HOW joint creating seal preventing passage of flame,heat, and smoke through joint. Cured and odor free providing immediate protection. PROFILE SPECIFICATIONS Hot dipped galvanized steel complying with ASTM A653 and ASTM A1003 Structural Grade 50 Type H for Grade 33 Type H for a minimum coating of G-60 and complies with ASTM C645. Track member width 2-1/2, 3-5/8, 4, 6, and 8. Gauge (mils) 20, 18, 16, and 14 GA (33, 43, 54, and 68 mil). Nominal Joint Width 100% Compression Active ingredients protect either 1, 2 or 3 hour fire rated joints. In a pan deck assembly the intumescent expands over the mineral wool creating a seal and eliminating the need for fire resis tant sprays. 100% Extension Deflection = Compression + Extension Compression Only 1 1 1 2 2 Intumescent tape 2mm. Length 10 0 standard custom sizes available. Deep leg track with 2-1/2" to 3-1/4. The external groove also provides increased sound ratings,as it reduces sound vibrations. The external groove provides an air tight assembly when it contact with drywall. Patent No. US 7, 617, 643 B2 Track Member Width Length Gauge (mils) 2 ½, 3 5/8, 4, 6, and 8 10 0 Drift slots on the web are optional. 20, 18, 16, and 14 GA (33, 43, 54, and 68 mil) 11

FAS TRACK DL2 DETAILS FAS TRACK CHASE WALL AT CONCRETE SLAB FAS TRACK PERPENDICULAR TO FLUTED DECK S2 C HW-D-0576 CHASE WALL AT CONCRETE SLAB. HEAD OF WALL SYSTEM 1, PARALLEL TO BEAM ASSEMBLY. S1 UD HW-D-0577 PERPENDICULAR TO FLUTED DECK. 100% COMPRESSION & 100% EXTENSION HEAD OF WALL SYSTEM 1, FAS TRACK DL2 PERPENDICULAR UNDER FLUTED DECK. FASTDL2 2 FASTDL2 2 (SEE UL LISTING FOR WALL FIRE RATING) UL-2079 TEST STD. FAS TRACK GYPSUM WALLBOARD CEILING FAS TRACK CENTERED DIRECTLY UNDER BEAM 2 INCH (1) S9 TJ HW-D-0578 GYPSUM WALLBOARD CEILING. HEAD OF WALL SYSTEM 9, GYPSUM WALLBOARD CEILING. S9 UB HW-D-0579 CENTERED DIRECT UNDER BEAM. HEAD OF WALL SYSTEM 9, CENTERED DIRECT UNDER BEAM. FASTDL2 2 FASTDL2 2 12 800.775.2362 11

FAS TRACK DL2 DETAILS FAS TRACK CHASE WALL AT PAN DECK 2 INCH FAS TRACK CONCRETE SLAB 2 INCH S1 C PD HW-D-0580 PERPENDICULAR TO FLUTE DECK. S1 UD HW-D-0581 CONCRETE SLAB. HEAD OF WALL SYSTEM 1, FAS TRACK DL2 UNDER CONCRETE SLAB. FASTDL2 2 FASTDL2 2 FAS TRACK PARALLEL WITH FLUTED DECK 2 INCH FAS TRACK PERPENDICULAR I-BEAM PENETRATION 2 INCH S1G FASTDL2 2 TB HW-D-0582 PARALELL TO BEAM ASSEMBLY. HEAD OF WALL SYSTEM 1, PARALLEL TO BEAM ASSEMBLY. UNDER FLUTED DECK. HW-D-0583 PERPENDICULAR I-BEAM PENETRATION 1 NOMINAL GAP/2 TOTAL MOVEMENT 13

FAS TRACK DL2 DETAILS FAS TRACK CANILEVER UNDER I-BEAM 2 FAS TRACK PARALLEL WITH FLUTED DECK 2 INCH MOVEMENT S1 UD HW-D-0587 PARALEL WITH FLUTED DECK. HEAD OF WALL SYSTEM 1,PARALLEL AND OFFSET UNDER FLUTED DECK. HW-D-0601 REGULAR WALL SYSYTEM FASTDL2 2 FAS TRACK PARALLEL TO FLUTE (A) FAS TRACK PARALLEL TO FLUTE (B) HW-D-0620 PARALLEL UNDER PAN DECK CONFIGURATION A GAP1/2-1 HW-D-0620- PARALLEL UNDER PAN DECK CONFIGURATION A GAP 1/2-1 100% MOVEMENT 1 AND 2 HOUR FIRE RESISTANT ASSEMBLY. 14 800.775.2362

FAS STRAP FA S S T R A P CEMCO s NEW FAS Strap is the first accessory in the Fire Management product line. FAS Strap eliminates the requirement for filling the fluted deck with mineral wool or fire proofing for all walls running parallel with the fluted deck. By incorporating cold formed steel with intumescent into a composite product, CEMCO has again created a single step application that saves labor, time, and money. The UL assembly #HW-D-0524 allows the installer to use any one of CEMCO s top tracks. When combined with CEMCO FAS Track, there is no need for fire caulking or fire sprays. FAS FAS Strap is is made from 20 33, GA 43, galvanized 54, & 68 MIL sheet thick metal. galvanized The sheet standard steel. The width standard is 10-1/ width 2 is x 10-1/2 10-0 x long; 10-0 depending long; depending on theon the width of the pan deck custom widths are available. The profile width of the pan deck custom widths are available. The profile features two V-grooves running parallel down the center for rigidity. features Along two both V-grooves sides of running the width parallel a strip down of 1 intumescent the center for runs rigidity. continuous Along both down sides the length. of the The width intumescent a strip of 1 serves intumescent two purposes runs continuous first to seal down off any the fire length. from The passing intumescent from one serves side oftwo the purposes wall to the first other to seal and off second any fire to from reduce passing sound from transmissions one side of that are transmitted through metal to metal connections. the wall to the other and second to reduce sound transmissions that are transmitted through metal to metal connections. Member Width Length Gauge (mils) 10-1/2 10 0 20, 18, 16, and 14 GA (33, 43, 54, and 68 mil) 15

FAS STRAP SUBMITTAL SHEETS FAS TRACK PARALLEL WITH FLUTED DECK 1-1/4" MOVEMENT S1 UD HW-D-0524 PARALLEL WITH FLUTED DECK. HEAD OF WALL SYSTEM 1, PARALLEL AND OFFSET UNDER FLUTED DECK. FAST 2 FAS TRACK SHAFT WALL PARALLEL TO FLUTED DECK HW-D-0524 SHAFT WALL PARALLEL TO FLUTED DECK. 16 800.775.2362

FA S S H A F T W A L L T R A CK FAS SHAFT WALL TRACK - provides 1-1/4 total movement FAS Shaft Wall Track is an exclusive CEMCO Fire Management product that provides Firestopping for dynamic joints on shaft wall assemblies allowing up to 1 total movement. The flexibility of the FAS Shaft Wall Track product is used to protect dynamic joints in one and two hour rated shaft wall systems while still providing Level 3 (Seismic) movement. The unique design provides unencumbered movement by eliminating any requirements of fire caulking, spray, or contoured drywall cuts. The simple one step installation allows the shaft wall assembly to build from one side of the wall. 1 4 " 89 A 3 1 4 " 89 R 1 8 " A DETAIL A SCALE 2 : 1 1 8 " NOMINAL JOINT WIDTH 5/8" (FAS Track) 100% COMPRESSION 100% EXTENSION DEFLECTION = COMPRESS. + EXT. COMPRESSION ONLY 5/8" 5/8" 1-1/4" 1-1/4" R 1 8 " 1" Track Member Width (A) Length Gauge (mils) 2-1/2, 4 and 6 10 0 20 GA (33mil) 1 1 2 " FAS Shaft Wall Track has all the same qualities of FAS FAS Shaft Wall Track has all the same qualities of FAS Track; the Track; the front leg is exactly the same on both tracks. front leg is exactly the same on both tracks. The difference is in The difference is in the back leg; on the FAS Shaft Wall the back leg; on the FAS Shaft Wall Track the back leg is solid and Track the back leg is solid and used as a receiver for used as a receiver for 5/8 type X drywall. The 3 1/2 drywall 5/8 type X drywall. The 3 1/2 drywall rip is used to insulate the Head of Wall during a fire and allows the shaft rip is used to insulate the Head of Wall during a fire and allows the shaft wall assembly to receive two-hour fire rating on both wall assembly to receive a two-hour fire rating on both sides of the shaft wall. 120" 17

FAS SHAFT TRACK DETAILS - PROVIDES 1-1/4 MOVEMENT FAS TRACK FLUTED DECK SHAFT WALL 1-1/4 INCH FAS TRACK SHAFT WALL PARALLEL CANTILEVER UNDER BEAM S1 T FD HW-D-0525 SHAFT WALL AT FLUTED DECK. HEAD OF WALL SYSTEM 1, PERPENDICULAR TO SHAFT WALL UNDER FLUTED DECK. FASW 2 HW-D-0598 PARALLEL CANTILEVER UNDER SHAFT WALL ASSEMBLY 1/2 NOMINAL GAP FAS TRACK CONCRETE WITH SHAFT WALL 1-1/4 INCH MOVEMENT FAS TRACK SHAFT WALL PARALLEL TO BEAM 1 INCH MOVEMENT S2 C HW-D-0557 SHAFT WALL SYSTEM 2. SHAFT WALL S1G TB HW-D-0563 SHAFT WALL PARALLEL TO I-BEAM. HEAD OF WALL SYSTEM 1, PERPENDICULAR TO SHAFT WALL. UNDER FLUTED DECK. PROVIDES 1-1/4" -2' TOTAL MOVEMENT FASW 2 FASW 2 18 800.775.2362

FAS SHAFT WALL TRACK FAS TRACK SHAFT WALL SYSTEM AT STAIR WELL SLAB FAS TRACK SHAFT WALL UNDER BEAM 5/8" HW-D-0621 SHAFT WALL SYSTEM AT STAIR WELL SLAB HW-D-0622- SHAFT WALL UNDER BEAM 100% COMPRESSION & 100% EXTENSION 1&2 HOUR FIRE RESISTANT ASSMENBLY FAS TRACK BEAM PENETRATION AT SHAFT WALL FAS TRACK SHAFT WALL CANTILEVER UNDER BEAM HW-D-0623- BEAM PENETRATION AT SHAFT WALL.. NOMINAL JOINT 1/2-1 100% MOVEMENT HW-D-0653 PARALLEL CANTILEVER CONFIGURATION C UNDER SHAFT WALL ASSMEMBLY 1 NOMINAL GAP,100% MOVEMENT, 100% COMPRESSION L-RATING LESS THAN 1CFM 2 HOUR FIRE RESISTANT ASSMENBLY 19

FAS SHAFT DL2 DETAILS - PROVIDES 2 TOTAL MOVEMENT FAS TRACK SHAFT WALL FLUTED DECK FAS TRACK SHAFT WALL AT CONCRETE SLAB 2 INCH MOVEMENT S1 T FD HW-D-0584 SHAFT WALL FLUTED DECK. HEAD OF WALL SYSTEM 1, PERPENDICULAR TO SHAFT WALL UNDER FLUTED DECK. S2 T C HW-D-0585 SHAFT WALL AT CONCRETE SLAB. HEAD OF WALL SYSTEM 2, AT CONCRETE SLAB. FASWDL2 2 (SEE UL LISTING FOR WALL FIRE RATING) UL-2079 TEST STD. FASWDL2 2 (SEE UL LISTING FOR WALL FIRE RATING) UL-2079 TEST STD. FAS TRACK SHAFT WALL VERTICAL TIE-IN FAS TRACK PARALLEL CANTILEVER UNDER SHAFT WALL WW-S-0061 SHAFT WALL VERTICAL TIE-IN 1&2 HR FIRE RESISTANCE ASSEMBLY HW-D-0599 PARALLEL CANTILEVER UNDER SHAFT WALL ASSEMBLY 1 NOMINAL GAP 20 800.775.2362

FAS TRACK 500 - PROVIDES 1/2 TOTAL MOVEMENT CEMCO FAS TRACK 500 FAS TRACK 500 is the latest offering in the CEMCO Fire Management Product Line. FAS Track 500 will provide 1/2 total movement for solid concrete deck dynamic head of wall fire rated joints according to the strict requirements of UL 2079. The unique profile allows the intumescent to be pinched between the concrete deck and the top web of the FAS Track 500 at all times. This permanent gasket style seal provides smoke protection in ambient conditions and received the best possible rating from UL of below 1 CFM. 5/16" 5/16" Intumescent Tape Both Sides (G) DETAIL A SCALE 2 : 1 7/64" FAS-Track 500 3 1 4 " 1 1 8 " 1 R 8 " 1" Typical A (A) 1 1 2 " 120" CEMCO FAS SHAFT 500 FAS Shaft 500 is the latest Shaft Wall offering in the CEMCO Fire Management Product line. FAS Shaft 500 will provide 1/2 total movement in solid concrete deck dynamic head of wall fire rated joints. Up until now Shaft Wall dynamic head of wall joints have been very difficult to achieve and require the installer to apply fire caulking or fire spray above the shaft liner and around the studs. There is NO fire caulking or spray required with FAS Shaft 500 or FAS Track 500 making it the clean choice. 5/16" 5/16" Intumescent Tape DETAIL A SCALE 2 : 1 (G) 7/64" FAS-SHAFT 500 3" 1 1 8 " A 2" (A) 120" 21

FAS TRACK 500 HW-D-0625 SOLID CONCRETE DECK FAS TRACK 500 100% MOVEMENT-1/2 TOTAL MOVEMENT HW-D-0624 SOLID CONCRETE DECK FAS SHAFT WALL TRACK 500 NOMINAL GAP 1/4-100& MOVEMENT-1/2 TOTAL MOVEMENT SHAFT WALL ASSEMBLY 22 800.775.2362

Firestik Firestik Firestik is the innovative mechanical approach to Firestopping dynamic joints allowing up to 2 of movement in fire rated partitions. The flexibility of the Firestik product is used to protect dynamic joints in both standard cold formed steel/gypsum and CMU/block walls. The unique design provides superior movement capabilities while eliminating any requirement for fire caulk, spray, flute plates, drywall rips, or contour drywall cuts throughout head of wall joint assemblies. The simple design provides a positively attached fire-stopping that allows for 100% unencumbered movement experiencing no fatigue during life of the assembly. INTUMESCENT MATERIAL.079 THK X Y 1.50 PART NAME X Y ALLOWABLE VERTICLE MOVEMENT FS1 1.40 1 1 FS2 2.25 2 2 25 Code Compliance Firestik meets all standard building codes and its unique design provides industry solutions for meeting deflection requirements where other materials or systems are restricted by design, compressibility, elasticity, or bond strength characteristics. Firestik has been tested and is listed with both Underwriters Laboratories and Warnock Hersey/ITS Laboratories in accordance with: Air Leakage Rating Air leakage tests conducted and witnessed by UL on conditions using Firestik as the joint treatment established L-ratings of less than 1 CFM per lineal foot when using Firestik protection. UL 2079: Tests for Fire Resistance of Building Joint Systems ASTM E 1966: Standard Test Method for Fire-Resistive Joint Systems ASTM E-814: Standard Method of Fire Tests of Firestop Systems ULC S115-M95: Standard Method of Fire Tests of Firestop Systems Firestik has been evaluated by ICC-ES and is listed under approval number ESR-2012. Seismic Requirements Firestik is approved for Class III cycling requirements, 500 cycles at 30 cycles per minute, meeting seismic building code requirements. The Class III movement provides design advantages over mastic-reliant systems currently limited to level II (wind sway) capabilities of 500 cycles at 10 cycles per minute. Sound Control STC testing shows Firestik reduces sound transmission through head of wall joints. In comparison with acoustical caulks, the Firestik performs within the same STC range when measured on the same wall assemblies. 23

Firestik Deflection Capabilities of UL listed Dynamic Assemblies Approved deflection of firestop materials protecting dynamic Head of Wall (HOW) joints listed through UL are based on two major factors. The first, Nominal Joint Width refers to a joint created by an installed gap distance between the top of the wall sheathing and the overhead structure. The second, Movement capabilities refers to the maximum percentage of the nominal joint width that joint materials can deflect without compromise or failure at a given cycle rate based on three levels. Level I 1 cycle/min for total of 500 cycles (Thermal) Level II 10 cycles/min for total of 500 cycles (Wind Sway) Level III 30 cycles/min for total of 500 cycles (Seismic) UL listed dynamic HOW assemblies utilizing Firestik profiles are provided 100% movement capabilities during compression or extension for class I, II, or III movement. The following illustration shows deflection capabilities provided using Firestik as the HOW joint fire stop material: NOMINAL JOINT WIDTH 100% COMPRESSION 100% EXTENSION DEFLECTION = COMPRESS. + EXT. COMPRESSION ONLY 1/2"(FS1) 1/2" 1/2" 1" 1/2" 3/4"(FS1)* 3/4" 1/4" 1" 3/4" 1"(FS2) 1" 1" 2" 1" 2"(FS2)* 2" - 2"* 2" * - Total deflection limited to coverage provided by profile dimensions UL-2079- Test Standards HW-D-0419 - Concrete M-Track HW-D-0418 - Pan-Deck M-Track HW-D-0420 - Pan-Deck Other Tracks HW-D-0421 - Concrete Other Tracks HW-D-0451 - CMU/Block Wall w/ Flat Concrete Overhead HW-D-0452 - Parallel Under Structure Beam HW-D-0453 - Parallel Under Structure Beam - U-Track HW-D-0454 - Parallel Centered Under Flute HW-D-0455 - Parallel Centered Under Flute - U-Track HW-D-0461 - Parallel to Beam: Z-Clip/Drywall HW-D-0462 - Parallel Centered Under Valley HW-D-0463 - Parallel Cantilevered Off Valley HW-D-0475 - Under Layer Type "C" G500 Series HW-D-0476 - Shaft Wall Parallel to Beam: Flat Stock/Fire Proofing HW-D-0477 - Standard Wall Parallel to Beam: Flat Stock/Fire Proofing HW-D-0480 - Shaft Wall HW-D-0481 - CMU Wall Parallel to Beam: Flat Stock/Fire Proofing 24 800.775.2362

CEMCO 925-473-9340 Customer Service CEMCO 925-473-9340 Customer Service CEMCO 303-572-3626 Customer Service Marino\Ware 219-378-7100 Mike Fenbert www.marinoware.com Marino\Ware 800-627-8199 Gerry Compton www.marinoware.com CEMCO 800-775-2362 Customer Service CEMCO 817-568-1525 Customer Service Marino\Ware 800-504-8199 Bill Mayne www.marinoware.com CEMCO 925-473-9340 Customer Service 8 0 0. 7 7 5. 2 3 6 2 WWW.CEMCOSTEEL.COM Corporate Headquarters & Main Manufacturing Facility 263 North Covina Lane City of Industry, CA 91744 800.775.2362 Phone 626.330.7598 Fax Northern California Manufacturing Facility 1001-A Pittsburg Antioch Hwy Pittsburg, CA 94565 925.473.9340 Phone 925.473.9341 Fax Denver Colorado Manufacturing Facility 490 Osage Street Denver, CO 80204 303.572.3626 Phone 303.572.3627 Fax Ft. Worth Texas Manufacturing Facility 8600 Roy Rogers Blvd. Ft. Worth, TX 76140 817.568.1525 Phone 817.568.2759 Fax Printed on 50% recycled 25% post consumer waste