UNITS MUST BE INSTALLED AFTER PRESSURE TANK

Similar documents
Model 400 Chemical Feeder. Glass Water Systems

Automated Pure Water. Model 400 Non-Electric Dry Chlorine Pellet Feeder. Installation & Operation Information

SECTION 5 E-Treat Water Conditioning Systems

SRO-1000 SRO-2000 SRO-4000 INSTALLATION MANUAL US 33 N. Churubusco, IN Ph. (260) Fax (260)

SRO-300 INSTALLATION MANUAL

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products

Owner s Manual Calcite Cartridge System

Escale Vessel. Installation and User Guide

Installation and User Manual ispring 3-Stage Ultra-Filtration Water Purifier

Features Reliable, DOW FILMTEC Membrane 4 - Stage Reverse Osmosis System - Part Number:

OWNER S MANUAL. Model 845. RFV Dye Marking System /15

Product Name. Here. FLUORAway. Operator s Manual. Histology Innovation for a NEW Generation. Catalog # FA-S. A Division of General Data Healthcare

3M Water Filtration Products Model SGLP-RO Reverse Osmosis System- Quick Installation Guide

HD Firewall Mount 850 all, S/V , C ipd #

A solution to your outdoor softener installation.

Specifications 9-Inch 10-Inch

ESSENTIAL FOR SURVIVAL

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

INSTALLATION, MAINTENANCE & WARRANTY GUIDELINES

ispring Whole House Water Filter System WHOLE HOUSE USER MANUAL

DIAPHRAGM BRAKES MODELS ''J'' AND ''K''

Installation / Operation Manual. Nitrate / Sulfate Water Treatment System

General Safety Information

Thank you for purchasing an Aquatic Life Classic Reverse Osmosis & Deionization Water Unit.

Installation Manual. LIFETIME LIMITED WARRANTY Warranty applies to select Residential faucets only. Pressure Balance Valve TSPVR & TSPTR

BG-PURE Reverse Osmosis Drinking Water System Performance Data Sheet

GC-X360S-W GC-X360S-B

Precision Roller Pinion System Models RPS16, RPS20, RPS25, RPS32, RPS40 LINEAR MOTION CONTROL PRODUCTS FORM NO. L A-1204.

Circular Expansion Cement Curing Kit Instruction Manual

PRODUCTS AIR CHAMP. User Manual. Diaphragm Brake. 4", 8" and 12" Hinge Top Diaphragm Brake FORM NO. L M-0914 FORM NO.

NOTES P: 888-H2O-LOGIC ( ) F:

New Advanced Environmental Air Treatment System

SQ-1 ROOF TRUSS WEG-IT TABLE

Pallet Jack 4,400 Lbs Capacity Model #31001

MODELS: SM & SMSS

Installation, Operation, and Maintenance Manual Aquapurion 600 GPD Line Pressure Reverse Osmosis System

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

ipd Intercooler S60 5cyl turbo V70/XC70 5cyl turbo ipd #114813

Installation Manual for SGLP-CL Series Reverse Osmosis Filtration Systems

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

DLB-23 Shower Enclosure Installation and User s guide

Everything in its place. OWNER S MANUAL. TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907

System Specifications

92831 TEL: (714) FAX:

Processing of 8-well strips under vacuum

STRONG-SEAL GROUT 250 AND GROUT 1000 SPECIFICATIONS for Void Filling And Leak Stoppage.

High Temperature Aging Cell Instruction Manual

ispring Whole House Water Filter System WGB21B USER MANUAL

Please read through the usage and service instructions outlined in this owner s manual before operating the unit. Warnings Diagrams...

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

TEACO TRUCK DOCK PARK ASSISTANT. MODEL DockView -16 FORWARD/REVERSE READING DISTANCE INDICATOR

Thank you for purchasing an Aquatic Life Twist-In (TI) Reverse Osmosis & Deionization Water Unit.

DESCRIPTION SAFETY: WARNINGS ORDERING INFORMATION T01-B INSTALLATION INSTRUCTIONS DROP-IN AND FREESTANDING BATH K-11343T / K-11344T

Date. Invoice No. Job No. SPEL Ecoceptor / 4000 / 6000 / 8000 Series. Operation & Maintenace Manual.

Master-Seal Surface-Applied Waterproofing System

1 YEAR FROM DATE OF PURCHASE

WH5-2 Iron & Hydrogen Sulfide Reduction Filter Package

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

SQ-1 INTELLIGENT ROOF

SCRUBBERS. Owners Manual. de-chlorinators.

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

BlazeMaster Fire Protection Fittings Accessories

Membrane System User s Manual. L1-Series

DIE CAST ALUMINUM & THERMOPLASTIC SUMP PUMP

PURE WATER. Installation, Operation and Maintenance Manual. Under Counter Water Filtration System Model PWDWHCUC1. Table of Contents !

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

VWR Zero Air Generator Models , Installation, Operation, and Maintenance Manual. Bulletin TI-ZAG3500-L1466

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Pr MaxTM HOME. Propur HOME Whole House Water Filtration System FULL SPECTRUM HOME

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Electrostatic Technology, Inc. A Subsidiary of Nordson Corporation

Model WHARSS5. How to install, operate and maintain your In-Line Refrigerator Water Filtration System. Do not return unit to store

LIMITED WARRANTY DISCLAIMER OF IMPLIED WARRANTIES & CONSEQUENTIAL DAMAGES

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

DUST FREE ACTIVE Total Home Air Purification

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

HydroLink Watering System with Snake Tubing Installation, Operation & Maintenance Manual

Operator s Manual for Morse Kontrol-Karrier with Spark Resistant Parts and Air Power Tilt

Installation and Operation Manual

BIN LINER INSTALLATION MANUAL IMPORTANT!

SAVE THESE INSTRUCTIONS

Distribution Box INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS UGC

Membrane System User s Manual

READ AND SAVE THESE INSTRUCTIONS SEISMIC. Cer tification Option. Installation Manual

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

PRO-POXY 400 A.11. New technology for all weather anchoring... PRO-POXY 400! BENEFITS:

KM-201BAH KM-260BAH KM-201BWH KM-260BWH SELF-CONTAINED CRESCENT CUBER INSTRUCTION MANUAL L1F (100109)

WHOLE HOUSE FILTER &

92831 TEL: (714) FAX:

PRO-RO 6-Stage Reverse Osmosis System

MASTER. Installation and Operation Manual. Water Conditioning Corp. DECHLOR Series Flow-Through Residential Carbon Filters.

Contact. (984) Distribution Drive, #E Morrisville, NC 27560

Mobile Drum Carrier. Owner s Manual

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09008

AIR CHAMP PRODUCTS. Micro Clutch and Micro Brake FORM NO. L J-0110

PRO-RO 6-Stage Reverse Osmosis System

Installation and Operating Guide Document No SmartDesiccator Copyright 2017 Terra Universal Inc. All rights reserved. Revised February 2017

Transcription:

Chlorine setting in P.P.M. for center tube and cap Hole #1 = 2 P.P.M. Hole #2 = 8 P.P.M. Hole #3 = 30 P.P.M. Hole #A = 3.5 P.P.M. Hole #B = 13 P.P.M. Hole #C = 40 P.P.M. All holes closed will deliver 60 P.P.M. per pump cycle. This chart is for a 42 gallon or equivalent pressure tank. When using an 80 gallon pressure tank, the P.P.M. amount will be 50% less per pump cycle. A 20 gallon pressure tank will yield 2 times the amount. Each number or letter will show a different hole in the cap. Line up the 3 holes in the cap with the proper number or letter directly under it (as per figure 1). The hole in the tube should show in the center of the hole in the cap. UNITS MUST BE INSTALLED AFTER PRESSURE TANK Install PVC check valve BEFORE the feeder if water is used after pressure tank and before feeder inlet. USE CAUTION WHEN DRAINING CHLORINE: Chlorine can bleach clothes and may burn eyes and skin. See manufacturer details for proper handling. When removing center tube for cleaning, check hole setting in cap. After cleaning, be sure the setting is the same before replacing the cap. Center tube MUST BE REMOVED AND CLEANED or replaced with the extra center tube and cap each time before refilling. REMOVE CHEMICAL FROM "FEEDER" WHEN NOT BEING USED!

Refilling Information for Model 400 1. Shut off water ahead of feeder. 2. Open drain valve after feeder and relieve line pressure. 3. Unscrew top (No. 4) and remove adjustment tube (No. 8) to drain unit and replace with a clean tube and cap (No. 7). To clean the removed tube and cap, soak in a mixture of Muriatic Acid. One part Muriatic Acid to 5 parts water. Always pour the acid into the water. ADHERE TO THE WARNINGS FOR HANDLING AND USE OF MURIATIC ACID. Tube and Cap can also be cleaned by soaking in white vinegar over night or longer. 4. Unit Housing needs cleaning when center hole has built-up (under tube No. 8). Unscrew unions (No. 14), remove housing and soak in same mixture of Muriatic Acid as tube No. 8 until clean. Be sure flow arrow is in the same direction when reinstalling housing. 5. Fill with chlorine tablets to the bottom of cap (No. 7) and do not add water to the unit or operation will be inhibited. It may take a few pump cycles before chlorine is dispensed. 6. Replace top (No. 4) and close drain valve. 7. Turn on water. If unit is used for odor removal, do not refill until odor returns to minimize chemical use. DANGER: DO NOT MIX DIFFERENT TYPES OR BRANDS OF CHLORINE AN EXPLOSION CAN OCCUR! Part# Description 1 Cover 2 Cap Screw 3 Spacer 4 Lid 5 Inner Lid 6 Lid O-Ring 7 Adjustable Cap 8 Flow Tube 9 Lock Clip 10 R.O.F. "Ring" 11 Non-Functional Valve 14 Union Nut - each 15 1 1/2 Socket Adaptor 16 Union O-Ring (2) 17 3/4 Adaptor - each 20 Functional "rate of feed" valve 21 Lid Wrench

INSTALLATION AND OPERATION INFORMATION The UNIVERSAL CHEMICAL FEEDER will operate on a varying pressure such as a home well system or on a constant pressure such as a sprinkler or pool system. When used as a constant pressure system, the optional rate of feed valve (No. 20) must replace N0. 11 valve as received. A charcoal filter must follow the CHEMICAL FEEDER on a varying pressure system for proper operation. Tests have shown that one cube of coconut shell based activated carbon is the best carbon to use (grade 9/50, mesh 8/30). We recommend installing the CHEMICAL FEEDER and filter tank before or after the softener. If installed before the softener, the filter will need periodic back washing. There are seven positions for varying the amount of chemical feed. Rotate the top cap (No. 7) so there is a hole showing through the level desired. There are two hole selections for each hole in the cap (No. 7). The smaller hole will dispense the greatest amount and selecting a lower hole on the cap will increase the output. Approximate chlorine readings using a 42 gallon pressure tank out of the CHEMICAL FEEDER per pump cycle in PPM, for each hole are: 1=2, A=3.5, 2=8, B=13, 3=30, C=40 and with no holes showing, the off position is 60 plus. These readings are obtained with no iron or hydrogen sulfide using the chlorine. Variables that will change the dilution are: pressure tank size, large volumes of water flow while pump is building pressure to shut off, horse power of the pump, and a water logged pressure tank or air pressure is low or high in the air bag. The CHEMICAL FEEDER will dispense the same amount of chemical for each cycle of the pump from maximum to minimum pressure. When used on a constant pressure and flow it is necessary to replace the valve (No. 11). Replace it with the optional adjustable valve (No. 20). It may be necessary to install the optional screen filters (No. 19) in the top inside hole of (No. 8) and screen (No. 18) in the adjustable inlet hole when using chemicals other than chlorine. When using the unit for constant pressure and flow such as a sprinkler system or pool; install the unit on the output to the sprinkler heads or on the return line to the pool. The adjustments for the varying pressure system should have no holes shown through in the off position. The amount of chemical dispensed is controlled with the adjustable valve on the outside of the unit. It may be necessary to adjust the unit if flow is increased or decreased. (Actual size of the CHEMICAL FEEDER - 10.5" high X 11.5" long Empty weight - 6.5 lbs.) Maximum tested pressure is 80 lbs. CAUTION: USE ONLY CALCIUM HYPOCHLORITE CHLORINE TABLETS FOR POTABLE WATER. THEORY OF OPERATION After filling the unit with chemical to no higher than the bottom of the adjustable cap or less and returning water flow, fluid will flow into the chemical container mixing with the chemical until the air trapped in the top of the unit is compressed to the same pressure as the line pressure. When the line pressure is reduced, compressed air in the air chamber will force fluid from the container down and up through the outside center tube and down the inside tube to the water line until pressure is equal or until the fluid level reaches the hole that is open in the outside tube. At that time, the compressed air will flow through the hole into the outside tube, down the inside tube and no more fluid will flow. This procedure will occur on each pump cycle. The outside tube has six (6) holes with three of them smaller. The cap can be rotated to select either a large hole or a small hole in six different locations. During fluid flow, a small amount of fluid will flow through the hole selected thereby diluting the fluid flowing up through the outside tube. Most chemical solutions are heavier than water and the top of the fluid is not as heavily saturated as the bottom of the container. Selecting a small hole will increase the chemical concentration and selecting a lower hole increases the solution output. The unit can be used as a venturi operation for operations other than varying pressure. In this mode, the cap may be rotated so there is no hole through the outside tube or left with the hole through the outside tube to help dilute the fluid if needed. The chemical solution put out is controlled with the optional rate of feed valve on the outside of the unit. WARNING: DO NOT MIX DIFFERENT TYPES OR BRANDS OF CHLORINE AN EXPLOSION CAN OCCUR.

MODEL 400 CHEMICAL FEEDER To oxidize 1 PPM of Hydrogen Sulfide (H 2S), it takes 2.2 PPM of Chlorine (Cl 2). To oxidize 1 PPM of Iron (Fe) it takes.64 PPM of (Cl 2). Example: If you have a 4 PPM of Fe and 1 PPM of H 2S, look on the vertical portion of the graph labeled PPM and start at 4 and move horizontal to the line marked Iron - Fe x.64 Cl 2 and then down to the bottom of the graph marked Chlorine - Cl 2 PPM. It should intercept the bottom at about 2.6. This is the amount of Cl 2 needed to oxidize 4 PPM of Fe. Now look on the vertical portion of the graph labeled PPM and start at 1 and move horizontal to the line marked Hydrogen Sulfide - H 2S x 2.2 Cl 2 and then down to the bottom of the graph. It should intercept the bottom at about 2.2. This is the amount of Cl 2 needed to oxidize 1 PPM of H 2S. Example in dotted lines: 4 PPM Fe requires 2.6 PPM of Cl 2. 1 PPM H 2S requires 2.2 PPM of Cl 2. Total Cl 2 required is 2.6 + 2.2 = 4.8 PPM Cl 2. Higher PPM than the graph can be calculated. Example: 20 PPM H 2S x 2.2 Cl 2 = 44 PPM of Cl 2. 20 PPM Fe x.64 Cl 2 = 12.8 PPM of Cl 2 Use with retention tank if iron or sulfide is 2 P.P.M. or more. If using a 42 gallon pressure tank, the No. 2 hole on the chemical feeder should be used. This will dispense about 8PPM of Cl 2, and a filter with 1 cube of activated carbon after the unit will eliminate the excess Cl 2. If using the chemical feeder for iron removal or extremely high H 2S, it is necessary to use a retention tank and a back washing valve on the carbon filter. The Chemical Feeder will hold about 4 lbs. of Cl 2 (1 gram tablets). If it is adjusted to the No. 1 hole, and using a 42 gallon pressure tank with 1 cube of activated carbon, the system should process approximately 20,000 gallons of water before the unit would need refilling.

MODEL 400 CHEMICAL FEEDER LIMITED WARRANTY AUTOMATED PURE WATER, INC. warranties it s components and parts as follows: For a period of three (3) years from the date of installation, Automated Pure Water, Inc. will repair or replace any part or component found to be defective in materials or workmanship, provided it was used in accordance with the printed instructions and all building codes in effect, and system did not exceed 80 pounds per square inch or different types of chlorine were mixed together. Defective parts must be returned for inspection. Automated Pure Water, Inc. will not be responsible for any charges or other costs, resulting from the removal or installation of repaired or replaced parts or components. THE DURATION OF ANY IMPLIED WARRANTY GRANTED BY STATE LAW, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PRUPOSE, SHALL BE LIMITED TO THE SPECIFIC WRRANTY PERIODS STATED ABOVE. Some states do not allow limitation on how long an implied warranty lasts, so this may not apply to you. AUTOMATED PURE WATER, INC. EXPRESSLY DISCLAIMS AND SHALL HAVE NO LIABILITY WHATSOEVER IN EXCESS OF THE PURCHASE PRICE OR PARTS OR COMPONENTS FOR ANY LOSS, DAMAGE OR INJURY ATTRIBUTABLE TO MANUFACTURER S NEGLIGENCE OR FAULT AND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, from (a) the design, manufacture, sale, delivery, installation, repair, operation or use of the part of component or any part thereof, (b) any actual or alleged breach or nonperformance by Automated Pure Water, Inc. under this limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state. AUTOMATED PURE WATER, INC. 4350-5th Street SW, Vero Beach, FL, 32968, (772) 567-2488, Fax (772) 567-2503 Should you have a problem obtaining chlorine, call for authorized dealer in your area