VININGS JUBILEE SPECIALTY CENTER AND VININGS JUBILEE COURTYARD SIGN CRITERIA

Similar documents
Uniform Sign Plan (USP) Searstone 08-USP-009

Uniform Sign Plan (USP) Millpond Village 00-USP-003

MASTER SIGN PLAN BRADFORD

DESIGN GUIDELINES FOR ON-PREMISE SIGNS AND AWNINGS (Adopted June 17, 2003)

KIOSK DESIGN CRITERIA

Sign Tool Kit for Local Area Businesses Village of Arlington Heights Prepared by the Planning & Community Development Department January 2010

4.SIGNAGE INTRO TO CHAPTER 4. Sign Definitions 58

TOWN OF DENTON SIGN DESIGN GUIDELINES

5.0 SIGNS 5.1 SIGN DEFINITIONS

Uniform Sign Plan (USP) Harrison Square 89-USP-003

4.SIGNAGE INTRO TO CHAPTER 4 CHAPTER CONTENTS. Sign Definitions 58

Milliken Business Center

Uniform Sign Plan (USP) South Hills Mall and Plaza 02-USP-007

Wall Signs. Appearance Code and Design Guidelines

DESIGN REVIEW COMMITTEE AGENDA ITEM

OVERVIEW OF SIGN BY-LAW HERITAGE GUIDELINES

Design Standards and Guidelines - Signage

NEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1

Tenant Sign Criteria. Guidelines. Requirements. The Shoppes at the Village Piazza

TENANT CRITERIA MANUAL INSERT PHOTO HERE

Signage Criteria June 12, 2017 TENANT SIGNAGE CRITERIA

A G E N D A OLD TOWN DESIGN REVIEW COMMITTEE SEPTEMBER 12, 2016

Pittsburgh Business Centre

Design Guidelines - Commercial Buildings

STANDARDS FOR. Exterior Donor Signage

Submittal Requirements for Administrative Design Review of Signage

Carrollton Sign Design Guidelines Commercial Business Districts & Transit-Oriented Development

Planning Commission Staff Report Thursday, January 12, 2017

Architectural Commission Report

84usp001 (Lochmere PUD) Page 1 of 5

Master Signage Exhibit

TRADITION. Master Sign Program

3.44. Development Guidelines

Uniform Sign Plan (USP) Carpenter Village PUD 02-USP-999

City of Oxnard Central Business District. Design Criteria For Over-The-Counter Downtown Design Review Permits

City of Oxnard Central Business District. Design Criteria For Over-The-Counter Downtown Design Review Permits

TRADITION. Master Sign Program

DESIGN GUIDELINES FOR COMMERCIAL, INDUSTRIAL AND MIXED-USE BUILDINGS

found on the building don T use imitation stucco or siding materials such as Dry-vit, aluminum siding or metal panels

Architectural Review Board Report

No.-O CASHIERS COMMERCIAL AREA DEVELOPMENT ORDINANCE REVISIONS Amended June 02, 2016

Section 4.05 Architectural and Site Design Requirements. [Amended Ordinance # 09-04]

SUGGESTED GUIDELINES Design Review Board

City of Rowlett 6 November 2012 Form Based Code ARTICLE 5 SIGNS 5.1 INTENT.

SUGGESTED GUIDELINES Design Review Board

Uniform Sign Plan (USP) Gateway Centre 87-USP-003

CRA DISTRICT MAP. KISSIMMEE CRA - Volume III - Architectural Standards

4809 W. Hwy 290 Sunset Valley, TX 78735

Northpointe Renovation EPN #1701 F/A Prroject #17027 September 8, 2017

Stanford Industrial Park. Design Guidelines

in Vermilion s Downtown Historic District

A. The temporary use of one on-premise portable sign provided that the portable sign Page 1 of 8 07/26/2016 ORD.821

URBAN & ECONOMIC DEVELOPMENT 1 KENNEDY PLAZA, UTICA, NEW YORK PH FAX

The Village Architectural Control Policy and Guidelines (ACPG)

TENANT DESIGN MANUAL UPDATED JUNE 2015

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

Uniform Sign Plan (USP) Weston Planned Unit Development (PUD) 86-USP-007

V. Signage. A. General Overview. Cornerstone - Village of Grayslake Pattern Book GENERAL SIGNAGE DESIGN STANDARDS

STAFF BRIEF. Denver Art Museum Fentress Architects ArtHouse Design. Color A. Wall Signs Project Id Red Pages in elevation, details on page 17.

Link to APPENDIX Title Page. Appendices

a. Type of Signs Freestanding signs shall be limited to ground signs or post & arm signs. [Amended Ordinance #06-14]

ORD WHEREAS, the public necessity, convenience, general welfare and good zoning practice so require;

Tenant Signage Criteria. June 12, 2017

Architectural Review Board Report

R Scale: 3/32 = 1-0. Scale: 3/32 = 1-0

TENANT DESIGN CRITERIA MALL: C

The following provisions shall apply to the Plant Riverside sign district:

Architectural Commission Report

Section PANEL SIGNAGE

SECTION OUTLET, PULL, AND JUNCTION BOXES

TENANT DESIGN CRITERIA MALL: D FOOD COURT SOUTH SIDE

APPLICATION FOR FREESTANDING SIGN PERMIT

In the event of a discrepancy between this criteria, mall criteria, lease, and lease exhibits, the most stringent

Facade Grant Program

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

In the event of a discrepancy between this criteria, mall criteria, lease, and lease exhibits, the most stringent

RE: canopy Hotel project Conditions for final SPA Signage and minor Site Plan changes/updates

SECTION TURBINE VENTILATORS

HISTORIC LANDMARK COMMISSION STAFF REPORT

COMPREHENSIVE SIGN PROGRAM

DALLAS-FORT WORTH INTERNATIONAL AIRPORT

Architectural Review Board Report

Architectural Commission Report

Borough of Phoenixville Historical Architectural Review Board

SIGNAGE Scope of Standard

Any sign that is legally existing as of the effective date of this ordinance shall be grandfathered.

Raintree Springs Association, Inc. Architectural Control Policy. Effective Date: May 7, 2007

SECTION GYPSUM BOARD ASSEMBLIES

Embry-Riddle Aeronautical University Signage Specifications 03/25/2008

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

Arroyo Vista at Gainey Ranch

Uniform Sign Plan (USP) Keisler Drive Office Park 89-USP-004

Framed Decorative Panel Systems

TRADITION. Master Sign Program

City of Aurora, Ohio. Architectural Board of Review. Residential Guidelines

Master Sign Plan (MSP) Kildaire Plaza

The following provisions shall apply to the River Street-Factors Walk District: Temporary sign. Temporary signs shall be permitted provided that:

Architectural Commission Report

GENERAL SIGN STANDARDS

DIVISION 5 METALS COLD FORMED METAL FRAMING Structural Metal Stud Framing

Transcription:

VININGS JUBILEE SPECIALTY CENTER AND VININGS JUBILEE COURTYARD SIGN CRITERIA ISSUED: JANUARY 2006 AMENDED: March 2009

General Signage Criteria This criteria sets forth the basic guidelines by which the Landlord will review and approve all Tenant signs for Vinings Jubilee Specialty Center and Vinings Jubilee Courtyard. The purpose of sign criteria is to ensure consistent, tasteful, quality signage throughout the center, setting specific restrictions as set forth below. The Landlord maintains the right to reject, or to require modification of any Tenant sign. 1. Number of Signs Permitted All Tenants will be required to have one (1) Tenant ID sign. Stores having corner storefronts may have one (1) on each storefront, but limitations will be enforced by the Landlord dependent on individual storefront circumstances and design. No tenant will be allowed more than one (1) Tenant sign per storefront. Tenant shall install at Tenant s expense an exterior sign conforming to these sign criteria and specifications. Tenant shall at all times keep all signs in good condition, in proper operating order and in accordance with all applicable government regulations. 2. Type of Signs Tenant may select one (1) Tenant ID sign shown on sheet 5.0-5.1 to apply their trade name or customary logo for identification. All signage is required to be constructed of aluminum. Tenant ID Signage Specification: 2" deep aluminum panel sign. Frame is 1" x 2" square aluminum tubing rolled to match radius as needed. Frame has 1" square aluminum tubing internal frame. Internal frame is welded on center with 2" tubing or recessed 1/2" inside 2" tubing. Face panel is 1/8" thick aluminum, welded to 1" square tubing internal frame. Painted per landlord specification. With tenant graphics as required. Tubing frame to be tapped for concealed stud mount. Tenant Blade Signage to be provided at discretion of landlord depending on architecture of storefront. Tenant Blade Signage to be purchased and installed by landlord and is the property of landlord. Storefront window graphic guidelines are indicated on sheet 7.0. and limited to Second Surface Applied White Vinyl. Second Surface vinyl is applied to interior surface of glass. Due to customization of individual Tenant Storefronts, final designs will vary and are up to the landlord's discretion. Tenant Signage, other than those illustrated in these guidelines, shall not be permitted. Storefront signage must be located within the storefront area defined by the Tenant s lease. Signing may occur anywhere within the limits of the basic storefront area as dictated by the architecture, but should maintain the design intent illustrated within these guidelines. 3. Lighting Lighting must be in keeping with the lighting plan of the overall center appearance. Sign illumination must be controlled on at sunset and controlled off at 10:00pm via timer as a minimum criteria. Signs shall be limited in brightness subject to Landlord s discretion. All signage must be illuminated using one of the following product lines and preferred vendors: (1) Abolite Angled Reflectors mounted with Abolite Gooseneck Wall Brackets unless otherwise approved by Landlord. Tenant may select one (1) Reflector size and one (1) Gooseneck Wall Bracket style shown on page 8.0 and 8.1. (2) Pen Lights ISSUED JANUARY 2006 Page 2 AMENDED MARCH 2009

Ardd and Winter, Inc. 4250 River Green Parkway, Suite A Duluth, Georgia 30096 770.368.2740 www.arddandwinter.com Vinings Lighting 2810 Paces Ferry Road, Suite 310 Atlanta, Georgia 30339 770.801.9600 www.viningslighting.com General Signage Criteria 4. Letters Sign Text is limited to Tenant s trade name or Tenant s customary logo as it appears in the Lease Agreement. Individual logos, typefaces, and colors shall be approved by landlord. Landlord reserves the right to limit use of logos. Any graphics other than formal tenant logo must conform to center graphics for standard typestyle as follows: Agenda Medium a b c d e f g h j k l m n o p q r s t u v w x y z A B C D E F G H I J K L M O N P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9 0! @ # $ % ^ & * ( ) 5. Color Specifications The following color specifications will apply to all Tenant signage: - Background color for all signs: Benjamin Moore Black Jack 2133-20 Benjamin Moore White Ice OC-58 Benjamin Moore Stardust 2108-40 Benjamin Moore Rustic Brick 2091-20 Benjamin Moore Marblehead Gold HC-11 Benjamin Moore Eucalyptus Leaf 2144-20 Benjamin Moore Autumn Orange 2156-10 - For frame of all signs: Benjamin Moore Black Jack 2133-20 Benjamin Moore White Ice OC-58 6. Submittal of Sign or Graphics Drawings Tenant must officially submit 2 copies of scale drawings of their proposed signage and lighting plan to the Property Manager for approval before any fabrication of signage begins. Written approval from the Property Manager is required prior to any fabrication. The drawings must indicate all pertinent information such as ISSUED JANUARY 2006 Page 3 AMENDED MARCH 2009

material, overall size, letter size, typestyle, accents, fastening system, color scheme, and proposed placement on elevation of building. Layouts must be resubmitted until marked Approved by Landlord. Incomplete layouts will be returned without approval. 7. Mounting of Signs Signs must be mounted as designated in this guideline. The landlord must approve any alternate method of mounting. Sign installer must verify conditions under which sign will be installed. Penetrations to the building structure or roof system must be approved in advance by the landlord and coordinated with the landlord s contractor for proper flashing and/or sealing methods. Any condition considered not suitable for proper and safe mounting is not permitted. 8. Code Requirements It is the tenant s responsibility to insure that all signs and their installation meet all code requirements set forth by government bodies having jurisdiction over Vinings Jubilee and that the appropriate signage permits are obtained. Cobb County Code Enforcement Division 191 Lawrence Street Marietta, Georgia 30060 770.528.2180 www.cobbcounty.org 9. Storefront Graphics Any graphics applied to storefront windows must be approved by Landlord. All graphics applied by tenant must be applied to interior side of storefront glass. See Page 13 for additional information. General Signage Criteria 10. Specific Limitations Landlord prohibits any additional storefront signage which does not conform to established design guidelines or convey a sense of permanence, use of quality materials, or enhance the overall project design. The following means of communication are prohibited. - Flashing, oscillating and moving. - Formed plastic or injection-molded. - Noise producing signs. - Odor producing signs. - Boxed or cabinet type unless recessed and an integral part of the storefront design and approved by the Landlord. - Exposed raceways, transformers, ballast boxes, crossovers, conduits, sign cabinets, etc. - Decals and lettering on shop window glass, door glass or any other part of storefront unless in keeping with design intent illustrated within these guidelines. - Temporary signs, banners, posters, notices, announcements or advertisements except standardized ail signs specifically approved in advance by Landlord. - Exposed labels of underwriter, manufacturer, etc. - Neon signage of any form is prohibited. - Paint, decorate or make any changes to the store front of the Premises. - Install any lighting, awning, or protrusions, or any exterior signs unless approved by Landlord. - Install any drapes, blinds, shades or other coverings on exterior windows and doors unless approved by Landlord. - Erect or install any signs, placards or decorations, or advertising media of any type that can be viewed from the exterior of the Premises, excepting only dignified displays of customary type in store windows. - Landlord reserves the right to limit or prohibit the use of logos. - No sign shall be installed without Landlord s written approval. ISSUED JANUARY 2006 Page 4 AMENDED MARCH 2009

11. Recommended Fabricators Denyse Signs Contact: Allen Denyse 4521 Industrial Access Road Douglasville, Georgia 30134 770.942.0655 www.denysesigns.com 12. Summary The above stated Sign Criteria is intended to provide flexibility to the sign designer in meeting each Tenant s needs. It also means that ample time must be allowed for the review and possible resubmittal. Likewise, we recommend allowing at least 4 weeks for manufacture and installation following design approval. Tenant must officially submit 2 complete sets of drawings and color samples, etc. to the Landlord s representative: Vinings Jubilee 4300 Paces Ferry Road Suite 245 Atlanta, Georgia 30339 770.438.8080 770.438.8181 fax In all cases, Landlord s judgment as the aesthetic quality, number, color size, material and method of installation of all signs shall be binding and final. ISSUED JANUARY 2006 AMENDED MARCH 2009 Page 5

STORE HOURS M-F 9:00-9:00 SAT 10:00-9:00 SUN CLOSED TENANT ID SIGN TO BE PURCHASED AND INSTALLED BY TENANT. SEE PAGES 5.0-5.4 TENANT BLADE SIGN TO BE PURCHASED AND INSTALLED BY LANDLORD. SIGNAGE TO BE PROPERTY OF VININGS JUBILEE. SEE PAGES 6.0-6.1 STOREFRONT GRAPHICS TO BE PURCHASED AND INSTALLED BY TENANT. SEE PAGE 7.0 SIGNAGE CRITERIA PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 4.0

X 1/2Y 1 6.0 (NOT TO EXCEED 50% OF STOREFRONT) 1/2Y WHITE FRAME 1/2Y MAINTAIN BORDER AROUND ALL SIDES OF SIGN Y 1/2Y 2Y STANDARD TENANT COPY VINYL GRAPHICS RUSTIC BRICK BACKGROUND OPTION A.1 2" DEEP ALUMINUM PANEL SIGN. FRAME IS 1" X 2" SQUARE ALUMINUM TUBING ROLLED TO MATCH RADIUS AS NEEDED. FRAME HAS 1" SQUARE ALUMINUM TUBING INTERNAL FRAME. INTERNAL FRAME IS WELDED ON CENTER WITH 2" TUBING OR RECESSED 1/2" INSIDE 2" TUBING. FACE PANEL IS 1/8" THICK ALUMINUM, WELDED TO 1" SQUARE TUBING INTERNAL FRAME. PAINTED PER LANDLORD SPECIFICATION. WITH TENANT GRAPHICS AS REQUIRED. TUBING FRAME TO BE TAPPED FOR CONCEALED STUD MOUNT. X (NOT TO EXCEED 50% OF STOREFRONT) 1 6.0 WHITE FRAME Y 2Y CUSTOM LOGO VINYL GRAPHICS MAINTAIN BORDER AROUND ALL SIDES OF SIGN MARBLEHEAD GOLD BACKGROUND OPTION A.2 2" DEEP ALUMINUM PANEL SIGN. FRAME IS 1" X 2" SQUARE ALUMINUM TUBING ROLLED TO MATCH RADIUS AS NEEDED. FRAME HAS 1" SQUARE ALUMINUM TUBING INTERNAL FRAME. INTERNAL FRAME IS WELDED ON CENTER WITH 2" TUBING OR RECESSED 1/2" INSIDE 2" TUBING. FACE PANEL IS 1/8" THICK ALUMINUM, WELDED TO 1" SQUARE TUBING INTERNAL FRAME. PAINTED PER LANDLORD SPECIFICATION. WITH TENANT GRAPHICS AS REQUIRED. TUBING FRAME TO BE TAPPED FOR CONCEALED STUD MOUNT. X (NOT TO EXCEED 50% OF STOREFRONT) 1 6.0 WHITE FRAME Y 2Y CUSTOM LOGO VINYL GRAPHICS MAINTAIN BORDER AROUND ALL SIDES OF SIGN WHITE BACKGROUND OPTION A.3 2" DEEP ALUMINUM PANEL SIGN. FRAME IS 1" X 2" SQUARE ALUMINUM TUBING ROLLED TO MATCH RADIUS AS NEEDED. FRAME HAS 1" SQUARE ALUMINUM TUBING INTERNAL FRAME. INTERNAL FRAME IS WELDED ON CENTER WITH 2" TUBING OR RECESSED 1/2" INSIDE 2" TUBING. FACE PANEL IS 1/8" THICK ALUMINUM, WELDED TO 1" SQUARE TUBING INTERNAL FRAME. PAINTED PER LANDLORD SPECIFICATION. WITH TENANT GRAPHICS AS REQUIRED. TUBING FRAME TO BE TAPPED FOR CONCEALED STUD MOUNT. EXAMPLE LAYOUTS TENANT ID SIGN PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 5.0

X 1 6.0 WHITE FRAME ALIGN Y VINYL GRAPHICS MAINTAIN BORDER AROUND ALL SIDES OF SIGN ALIGN OPTION B.1 2" DEEP ALUMINUM PANEL SIGN. FRAME IS 1" X 2" SQUARE ALUMINUM TUBING ROLLED TO MATCH RADIUS AS NEEDED. FRAME HAS 1" SQUARE ALUMINUM TUBING INTERNAL FRAME. INTERNAL FRAME IS WELDED ON CENTER WITH 2" TUBING OR RECESSED 1/2" INSIDE 2" TUBING. FACE PANEL IS 1/8" THICK ALUMINUM, WELDED TO 1" SQUARE TUBING INTERNAL FRAME. PAINTED PER LANDLORD SPECIFICATION. WITH TENANT GRAPHICS AS REQUIRED. TUBING FRAME TO BE TAPPED FOR CONCEALED STUD MOUNT. WHITE BACKGROUND X 1 6.0 WHITE FRAME Y CUSTOM LOGO VINYL GRAPHICS MAINTAIN BORDER AROUND ALL SIDES OF SIGN BLACK BACKGROUND OPTION B.2 2" DEEP ALUMINUM PANEL SIGN. FRAME IS 1" X 2" SQUARE ALUMINUM TUBING ROLLED TO MATCH RADIUS AS NEEDED. FRAME HAS 1" SQUARE ALUMINUM TUBING INTERNAL FRAME. INTERNAL FRAME IS WELDED ON CENTER WITH 2" TUBING OR RECESSED 1/2" INSIDE 2" TUBING. FACE PANEL IS 1/8" THICK ALUMINUM, WELDED TO 1" SQUARE TUBING INTERNAL FRAME. PAINTED PER LANDLORD SPECIFICATION. WITH TENANT GRAPHICS AS REQUIRED. TUBING FRAME TO BE TAPPED FOR CONCEALED STUD MOUNT. X 1 6.0 WHITE FRAME Y CUSTOM LOGO VINYL GRAPHICS MAINTAIN BORDER AROUND ALL SIDES OF SIGN EUCALYPTUS LEAF BACKGROUND OPTION B.3 2" DEEP ALUMINUM PANEL SIGN. FRAME IS 1" X 2" SQUARE ALUMINUM TUBING ROLLED TO MATCH RADIUS AS NEEDED. FRAME HAS 1" SQUARE ALUMINUM TUBING INTERNAL FRAME. INTERNAL FRAME IS WELDED ON CENTER WITH 2" TUBING OR RECESSED 1/2" INSIDE 2" TUBING. FACE PANEL IS 1/8" THICK ALUMINUM, WELDED TO 1" SQUARE TUBING INTERNAL FRAME. PAINTED PER LANDLORD SPECIFICATION. WITH TENANT GRAPHICS AS REQUIRED. TUBING FRAME TO BE TAPPED FOR CONCEALED STUD MOUNT. EXAMPLE LAYOUTS SCALE - NTS TENANT ID SIGN PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 5.1

STORE HOURS M-F 9:00-9:00 SAT 10:00-9:00 SUN CLOSED STORE HOURS M-F 9:00-9:00 SAT 10:00-9:00 SUN CLOSED ROOF MOUNTED TENANT ID TO BE CENTERED ABOVE STORE ENTRY WHENEVER POSSIBLE WALL MOUNTED TENANT ID TO BE CENTERED ABOVE ARCHITECTURAL FEATURES (DOORS, WINDOWS, AVAILABLE SPACE, ETC.) WHENEVER POSSIBLE MAINTAIN 6" CLEARANCE OF ALL ARCHITECTURAL FEATURES ACTUAL CLEARANCE ALLOWED MAY VARY AND IS AT THE OWNER'S DISCRETION ALIGN FRONT EDGE OF SIGN WITH FACADE OF BUILDING WHENEVER POSSIBLE WALL MOUNTED TENANT ID TO BE CENTERED IN AVAILABLE VERTICAL SPACE NOT TO EXCEED 4'-0" ABOVE ROOFLINE ACTUAL SIZES ALLOWED MAY VARY AND ARE AT THE OWNER'S DISCRETION ROOF MOUNT OPTION WALL MOUNT OPTION TENANT MOUNTING RECOMMENDATIONS PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 5.2

STORE HOURS M-F 9:00-9:00 SAT 10:00-9:00 SUN CLOSED STORE HOURS M-F 9:00-9:00 SAT 10:00-9:00 SUN CLOSED HANGING TENANT ID TO BE CENTERED IN ARCHITECTURAL FEATURES (DOORS, WINDOWS, AVAILABLE SPACE, ETC.) WHENEVER POSSIBLE TENANT ID TO BE CENTERED IN ARCHITECTURAL FEATURES (DOORS, WINDOWS, AVAILABLE SPACE, ETC.) WHENEVER POSSIBLE 7'-0" MINUMUM HANGING MOUNT OPTION EAVE MOUNT OPTION TENANT MOUNTING RECOMMENDATIONS PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 5.3

4" 1'-8" 1" x 2" ALUMINUM TUBING FRAME 2 1/2" 1/4" C L 1" x 1" ALUMINUM TUBING FRAME 10" 7" E 1/8" THICK ALUMINUM FACE 1'-6" 1 1/8" 3/8" 2" 1'-6" SIDE VIEW SCALE: 1-1/2" - 1' TENANT BLADE SIGN SCALE: 1-1/2" - 1' 1.0 TENANT ID SIGNAGE SECTION DETAIL APPROXIMATE SQUARE FOOTAGE: 4' GRAPHICS MAY BE APPLIED TO BOTH SIDES OF TENANT BLADE SIGN -FABRICATED ALUMINUM BLADE SIGN WITH DIGITAL GRAPHICS APPLIED TENANT BLADE SIGN / SECTION DETAIL FOR TENANT ID SIGNAGE PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 6.0

STORE HOURS M-F 9:00-9:00 SAT 10:00-9:00 SUN CLOSED 7'-0" CLEARANCE MINIMUM TENANT BLADE MOUNT RECOMMENDATION TENANT BLADE SIGN MOUNTING RECOMMENDATIONS PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 6.1

ALIGN ALIGN SECOND SURFACE APPLIED 3M WHITE VINYL SECOND SURFACE APPLIED 3M WHITE VINYL REQUIRED STORE HOURS FONT: AGENDA MEDIUM MAXIMUM CAP HEIGHT: 3/4" MAINTAIN 6" BORDER STOREFRONT GRAPHICS DETAIL SCALE: 1" = 4" MAXIMUM CAP HEIGHT 2" VINYL MUST ALLOW 6" BORDER AROUND EDGE OF ALL WINDOWS STOREFRONT GRAPHICS DETAIL SCALE: 1" = 2" C L C L C L C 6" 6" L 6" BORDER 6" BORDER STORE HOURS M-F 9:00-9:00 SAT 10:00-9:00 SUN CLOSED 1'-6" 2" 5'-0" 3'-6" STOREFRONT GRAPHICS ELEVATION SCALE: 1/2" = 1' STOREFRONT GRAPHICS PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 7.0

Shown with Gooseneck Bracket Accessory Required Lighting C All signage must be illuminated using Abolite Angled Reflector (AD) mounted with an Abolite Gooseneck Wall Bracket (GB) manufactured by LSI Lighting Solutions Plus. Lighting Manufacturers' Representative Ardd and Winter, Inc. 4250 River Green Parkway Suite A Duluth, Georgia 30096 770.368.2740 www.arddandwinter.com A Tenant may select one (1) Reflector size and one (1) Gooseneck Wall Bracket style shown on page 9.1. Approved Color Choices for Reflector and Gooseneck Wall Bracket GWT - Gloss White GBK - Gloss Black FIXTURE PREFIX HEIGHT (A) DIAMETER (B) NECK (C) WEIGHT (lbs) RATED WATTAGE LIGHT SOURCE LINE VOLTAGE B AD 100 10" 7" 5" 2.0 100 Watt Max Incadescent 120 AD 150 11-1/2" 9" 5-1/4" 2.0 150 Watt Max incadescent 120 AD 200 13-1/2" 11" 5-1/2" 2.5 200 Watt Max incadescent 120 ABOLITE ANGLED REFLECTOR DIMENSIONS LIGHTING SPECIFICATIONS PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 8.0

Abolite Gooseneck Wall Brack (GB) Choices: 9" 3" 14" 20" 6-11/32" 4-1/2" 4-1/2" 46 3" 14-1/2" 40-1/4" 2-1/2" 39" 2-1/2" 4-1/2" 5-1/2" 20" R 9" R 6" 23" 11" 10-1/4" 5-1/2" 10-1/4" 11" 22-1/4" 25-1/4" 4" 4-7/8" 4" 4-7/8" GB A 3-3/4" Single Reflector Gooseneck Wall Bracket. GB E 3-3/4" Single Reflector Gooseneck Wall Bracket. GB J 3-3/4" Single Reflector Gooseneck Wall Bracket. CWBM 1 and CWBL 1 - Contemporary Wall Bracket. 23" 32-5/8" 48-1/4" 4-1/2" 4-1/2" 46 3" 54-1/4" 17" 14-1/2" 6-3/4" 9" 12-3/8" 12-5/8" 9" 8" GB B 3-3/4" Single Reflector Gooseneck Wall Bracket. GB F 3-3/4" Single Reflector Gooseneck Wall Bracket. GB K 3-3/4" Single Reflector Gooseneck Wall Bracket. 4" 5" Mounting Hole Centers 23-7/8" 10-13/16" 4-1/2" 29-3/4" 7-1/2" 5-3/16" 31-3/4" 11-1/2" 7-1/2" 7-1/2" 43 6" 12-3/4" 28 7-1/2" 2" 32-1/4" 41-3/16" 4-1/2" 15 3" 18-1/4" 6" 3/4" N.P.T. 19-3/4" GB C 3-3/4" Single Reflector Gooseneck Wall Bracket. GB G 3-3/4" Single Reflector Gooseneck Wall Bracket. GB P 3-3/4" Single Reflector Gooseneck Wall Bracket. DWB 1 - Single Reflector Wall Bracket 2-1/2" 7-1/2" 4-5/8" 7-1/2" 1-3/4" 6-11/16" 4-1/2" 46 3" 4-1/2" 9" Short Elbow 1-3/8" 24-3/4" 22-1/4" 37-1/2" GB D 3-3/4" Single Reflector Gooseneck Wall Bracket. GB H 3-3/4" Single Reflector Gooseneck Wall Bracket. GB U 3 GWL - 3/4" Single Reflector Gooseneck Wall Bracket. LIGHTING SPECIFICATIONS PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 8.1

Sign Star Style A Sign Star Style B Sign Star Style C Twin Sign Star Style A Twin Sign Star Style B Twin Sign Star Style C Additional Lighting Signage may also be illuminated using Sign Star and Twin Sign Star lighting systems manufactured by B-K Lighting. Lighting Manufacturers' Representative Vinings Lighting 2810 Paces Ferry Road Suite 310 Atlanta, Georgia 30339 770.801.9600 www.viningslighting.com Tenant may select one (1) style that best reflects their lighing needs. Sign Star Style A Sign Star Style B Sign Star Style C Twin Sign Star Style A Twin Sign Star Style B Twin Sign Star Style C LIGHTING SPECIFICATIONS PREPARED BY SKY DESIGN ISSUED: JANUARY 2006 SHEET 8.2