Fire safety issues with balconies

Similar documents
This was followed by a Part 2 experimental scoping study focusing on the issue of external fire spread, to be covered in next month s issue.

Fire Behaviour in Different Building Types

Design guide to separating distances during construction, Part 4

Façade Fire Safety Design Practice Guide

Fire detailing. for non-combustible masonry structures. DRAFT 30th March Cover image, branding and accreditation to be developed

Permitted Development for Householders: Guidance from Communities and Local Government. March 2010 Department for Communities and Local Government

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

APPENDIX 17 GUIDELINES FOR RESIDENTIAL EXTENSIONS

6-Storey Residential Buildings Combustible Construction. A Regulator s Perspective City of Richmond, BC Canada

Fire performance of curtain walls and rainscreens

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia

SEPARATING WALLS CLASS 1A

SECTION : FIRE WALL AND FIRE SUPPRESSION REGULATIONS FOR R1-Z, R-2, R-3 ZONING AND PDD CATEGORIES

NEWS LETTER MARCH 27, 2009

THE UNIVERSITY OF HONG KONG LIBRARIES. Hong Kong Collection gift from Faculty of Architecture The University of Hong Kong

BRE Global Assessment Report

Householder Alterations Local Development Order

REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES

BRIEFINGS CONSTRUCTION. Fire safety on timber frame construction sites. 1 Background and history

Sustainable Retrofit A fabric first approach. Mark Elton Technical expert panel member Energy Saving Trust

Fire Hazard Properties of Eco- Block Wall Systems

Building Codes and Ordinances ARC 227

Changes to the built environment through sustainability and some implications for fire safety

Fire Engineering and Structures a Fire Service View

combustibility behaviour of insulation products

PRODUCT SUSPENDED. Rainscreen Cladding Compliance Guide When specifying Celotex RS5000 in buildings above 18 metres

WHOLE BUILDING BEHAVIOUR RESULTS FROM A SERIES OF LARGE SCALE TESTS

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Design guide to separating distances during construction

Refurbishment site guidance for solid-walled houses roofs

Final Revisions: Reason: For the avoidance of doubt and in the interests of proper planning.

BRE Global Classification Report

Overview. Introduction to Housing Solutions 2-3. Why Modular Housing 4-5. Standarised Designs Apartments Warranties.

Concepts. Products. Service. Providence Tower, London

30 Grimsdyke Crescent, Barnet, Herts, EN5 4AG

Cavity Wall Insulation. Installed costs: around 250 subsidised^ / yr

Refusal to issue a building consent for a house with insulated concrete walls at 11 York Road, Riversdale, Southland

Fire detailing. MMA: Guide to fire detailing in multioccupancy. for non-combustible masonry structures. DRAFT 30th March 2015

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

BRE Global Classification Report

11 Rundell Crescent London NW4 3BS

The Association for Specialist Fire Protection

2010 National Building Code Adoption and Associated Process Changes

4. Insulation of external walls

LOMBARDY ESTATE ARCHITECTURAL GUIDELINES RESIDENTIAL SECTOR

BUILDING CODE COMMISSION

1. Section 04300: Concrete Masonry Units

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

Section Topic Pages. Section 4 Design for horizontal escape Section 5 Design for vertical escape Section 6 General provisions 83-94

137 Beechwood Avenue Design Brief. Prepared by

June Non - Residential New Build Partition walls

Construction Studies Theory - Higher Level

siting, building and design guidelines April 2017 Newgate, Tarneit Design Guidelines

Determination under the Building Act 1991

Building Design Data

Light steel frame walls

1 The development hereby permitted shall be carried out in accordance with the following approved plans:

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

Rainscreen Cladding Compliance Guide When specifying Celotex RS5000 in buildings above 18 metres

Section 10 Residential Zone

Reference: 17/0150/HSE Received: 11th January 2017 Accepted: 11th January 2017 Ward: West Finchley Expiry 8th March 2017

A Handbook of thermal bridging details incorporating aircrete blocks

By James Tente, MCP, CBO,CFM

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

Multi-storey timber construction in the UK IRCC workshop, Vienna 7 June 2013 Dr Julie Bregulla Dipl-Ing, PhD, CEng, FICE

I want to build an extension or conservatory

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Thermal Control Layers: Insulation Materials and Systems

a) For the purposes of this Section, the terms listed below shall mean:

Amendments to the Approved Documents

Thermal bridging. Acoustic performance

Floors Walls Roofs. Jabroll. APPLICATION: Flat and Curved Roofs PRODUCTS: Vencel Resil Limited

Suspended timber upper floors

Note:

Building Science Control Layer Glossary. Façade Visible exterior face of a building, usually vertical or nearly so, but imprecisely used.

Cross Laminated Timber (CLT)

Amendments to the Approved Documents

MINIMUM PLAN INFORMATION REQUIRED FOR A BUILDING PERMIT

Ontario s Building Code

EUROPEAN ORGANISATION FOR TECHNICAL APPROVALS

NRC Research Update on Mid-Rise Wood Construction. Joseph Su Principal Research Officer, Fire Safety

Contact Details: Phone Fax . Work Description: New Building Extensions Refurbishment Change of Use. Yes No Method:

PIR Insulation XT/TL-MF. Insulation for Drylining Walls (Mechanically Fixed) Walls 04/ /0183

Centennial Hills Skilled Nursing Facility Fire Protection Report July 13, 2016 Revised September 15, 2016 JBA Project No

BRE Global Classification Report

Interior FRT Wood. References of Previous Model Building Codes

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

ASSEMBLY INSTRUCTION TG 2002

SUBURBAN RESIDENTIAL. QLDC PROPOSED DISTRICT PLAN [PART THREE] DECISIONS VERSION 7 lower density SUBURBAN residential

Committee Date: 28/11/2013 Application Number: 2013/06274/PA Accepted: 03/10/2013 Application Type: Full Planning Target Date: 28/11/2013

ModuSec. The Secure Modular Construction System. Designed To Meet All The Criteria Required For. The Protection Of Critical Environments.

european fire standards and national legislation

HPW Protocol Reference Manual

Guidance on U Values from Domestic Heating Design Guide

Construction Technology Revision Guide

A handbook of thermal bridging details incorporating Porotherm blocks

Refurbishment site guidance for solid-walled houses ground floors

Water control Vapor control and drying Room for growth

Executive summary. Fire Hazards of Exterior Wall Assemblies Containing Combustible Components v

Transcription:

Fire safety issues with balconies By Ciara Holland, Martin Shipp and David Crowder of BRE Global Introduction BRE Global carries out fire investigation activities on behalf of the Department for Communities and Local Government (DCLG). Through the Investigation of Real Fires contract BRE Global staff attend fires of special interest, investigate issues that may have implications for Building Regulations and the guidance that supports Building Regulations, such as the Approved Documents. Many dwellings, especially high-rise dwellings or blocks of flats, are now provided with a balcony. With high demand for housing and limited space, there is likely to be a continued increase in high-rise developments. As such, balconies are considered an important amenity in modern living; a 2014 report by the Homes and Communities Agency concludes the quality of the external environment is also crucial to residents experiences of daily life. Provision of adequately sized and well laid out private outdoor space could be improved [1]. Furthermore, the BREEAM scheme (BRE Environmental Assessment Method) gives points for the provision of a balcony where evidence provided demonstrates the provision of an adequate outdoor amenity space accessible for use by the building s occupants [2]. In addition, the presence of a balcony can offer residents an alternative means of escape in a fire event if their main exits from the dwelling are inaccessible (see Approved Document B Paragraph 2.7 [3]). Even if not by design, a balcony can provide a refuge area for occupants to await rescue from Fire and Rescue Services for which there are numerous documented cases (see [4] and [5]). However, fires on balconies are reported in the UK and overseas. BRE Global has reported on 24 fires which have started on balconies in the UK since 2005. The most common causes of those fires were arson, careless disposal of smoking material and misuse of barbeques. Indications are that fires on balconies are increasing with BRE Global reporting on six fire incidents in 2015 compared with one in 2005. Such fires can be quite severe and can spread to the balcony above, or spread to the flat above via windows, or, if the building s cladding material is inappropriate, up the entire façade of the building. These conditions endanger the lives of residents on higher floors and may also cause burning material to fall to the ground, with potential spread downwards or to adjacent buildings. Changes in building design and materials to meet energy performance criteria are changing the potential outcome of a fire on a balcony and the issues that now need to be considered by designers, managers and risk assessors, and fire-fighters. Case studies BRE Global is aware of cases where fire spread from a fire on a balcony to involve the building façade and in some cases spread from the floor of fire origin. Some of those incidents are summarised below. Whilst only fires in blocks of flats are reported here, such incidents are not limited to those types of buildings. Case study 1 Block of flats, July 2010 A deliberate fire was started on the balcony of a 12 th floor flat of a 16-storey residential block of flats constructed in the 1960s. As can be seen from Figure 1, the fire spread from the balcony of origin to the 15 th floor and the roof of the building. Several features of the building were attributed to the extent of fire spread including combustible insulating panels (which were clad onto the underside of all of the balconies), cladding panels (which had been installed onto the outer surface of the exterior wall and comprised a mineral fibre board face supported on timber battens, behind which there was a fibrous combustible insulation material) and plastic drain pipes (which were installed at each corner of the building and passed through the concrete floor slab on each floor). There was no evidence of any fire stopping, proprietary seal or sleeve where the pipe passed through the floor slab in the balcony which should have been provided to maintain the level of fire resistance afforded by the concrete floor slab.

Figure 1 Block of flats showing extent of fire damage caused by holes in compartmentation on balconies Case study 2 Block of flats, March 2011 A fire started on a balcony on the sixth floor of an eight and 16-storey purpose built block of flats constructed circa 2009 (Figure 2). The fire was caused by misuse of smoking materials; a plastic cup had been used as an ashtray and the lit cigarette had ignited the balcony components. The block was predominately of concrete construction with external surfaces covered in a variety of cladding systems, with cavities filled with a variety of rigid foam insulation. The construction detail of the balconies in the development seemed to vary; the balcony of fire origin appeared to be supported on an extension of the concrete floor slab of the main building structure but other balconies were timber built into the structure. The floor of the balcony was covered with timber decking on timber battens supported on polyethylene spacer rings. The spacer rings were, in turn, situated on a layer of foam insulation covered with a woven plastic sheet. It is this plastic sheet which is understood to have ignited and this, in turn, ignited the foam insulation under the decking. The fire spread under the decking consuming the foam insulation and also spread to involve insulation behind cladding systems on external walls. The fire also involved the ceiling of the balcony which had an expanded polystyrene insulation behind a render. The fire spread to the balcony of the neighbouring flat on the same level under the decking. There were no reported injuries as a result of the incident. Figure 2 Extent of damage to balcony, left, indicated by arrow and close-up view, right Case study 3 Block of flats, June 2015

Fire and Rescue Services were called at around 06:30 to a fire at a block of flats after a passer-by spotted flames on the balcony. The fire started on a second floor balcony of the five-storey purpose built block of flats. The block of flats was constructed circa 2005 of concrete construction. The balconies appeared to be Juliet-type decorative features. The balconies were the width of the window/door set and comprised a metal frame mechanically fixed to the building clad with timber panelling on four sides. The fire spread upwards to involve timber cladding on the third floor balcony (the uppermost balcony) and burning material dropping down ignited the first floor balcony. It was reported that there was smoke damage to at least one flat. The fire damaged the wooden Juliet-type balconies and cladding on one side of the balcony and the floor of the balcony and shattered patio doors of three of the flats. The cause of the fire is unknown. There were no reported injuries. Case study 4 Block of flats, August 2015 A fire started on the third floor balcony of a 13-storey purpose built block of flats constructed circa 2008. The block was part of a larger development of five high-rise blocks of concrete frame construction. A carelessly discarded cigarette is understood to have ignited the decking of the balcony. The balconies ran the full length of the building on the east and west faces with flat boundaries separated with anodised aluminium and glass privacy screens. The decking of the balconies is understood to have been European redwood timber. The fire spread from the decking to involve the timber/veneer façade and is understood to have spread beyond the privacy screen to the decking and façade of the adjoining flat. However, the fire is understood to have started next to the privacy screen. The fire was contained within the balcony on the third floor localised to the area of fire origin. The construction details of the underside of the balconies is not known but did not become involved in the fire and as a result is thought to have been non-combustible. The fire damage was limited to the external balcony and façade on the third floor. A number of occupants evacuated the property and there were no reported injuries as a result of the fire. Construction issues and fire safety While private external spaces are desirable features for property owners; the provision of balconies can pose some issues for designers and developers. There are numerous ways of incorporating balconies to a structure, from metal frame Juliet balconies to means of escape balconies which are an extension of the floor slab. The way a balcony is incorporated will in part depend upon the structural frame of the building. Whilst there are several drivers for balcony design, one key issue, related to fire safety, is that balconies can function as a cooling projection on the external surface of a building. Part L1 of the Building Regulations 2010 states Reasonable provision shall be made for the conservation of fuel and power in buildings by limiting heat gains and losses through thermal elements and other parts of the building fabric [6]. In other words designers need to carefully consider, among other design issues, thermal bridging when considering the introduction of a balcony. The prevention of cold-bridging to a structure will, in part, dictate the construction layout of the balcony and the materials used in its construction. Materials used for the insulation of buildings have changed considerably over the years with new innovative solutions introduced more frequently. As such designers and specifiers need to consider the impact the introduction of a product will have on all elements of the Building Regulations. It is clear from some of the incidents listed above that in meeting the requirements of Part L of the Building Regulations there was an adverse effect on meeting the requirements of Part B. Part B4 of the Building Regulations 2010 [6] states: 1. The external walls of the building shall adequately resist the spread of fire over the walls and from one building to another, having regard to the height, use and position of the building. 2. The roof of the building shall adequately resist the spread of fire over the roof and from one building to another, having regard to the use and position of the building. There is currently no specific guidance for balconies in Approved Document B (AD B), other than where balconies are designed as a means of escape. As such, requirements for fire safety with regards to balconies comes down to interpretation of the Building Regulations. Is a balcony part of the external wall and thereby subject to the same requirements of the Building Regulations or is it an external fixing? (N.B.

fixings are only mentioned in AD B to the extent that they impact on means of escape). This is most likely to depend on how it is incorporated into the building structure. As such, there are no specific statutory requirements in respect of external fire spread for the incorporation of balconies to a structure. Evidence would suggest that whilst fires on balconies appear to be increasing they have not impacted on life safety. This information would therefore suggest that there is no life safety basis to currently support changing the requirements. Where are we now? What should we do next? In essence, there have been no reported deaths (of which we are aware) caused by fire spread from a fire on a balcony. The case studies presented indicate that fire spread up the external face of a building from a fire on a balcony can occur. Whilst the case studies presented here, fortunately, did not result in any deaths or injuries, the potential remains for a fire on a balcony that does not consider all parts of the Building Regulations to pose a significant life safety issue. With the high demand for housing and the desire for homeowners to have private outdoor space it is likely that the presence of balconies in developments will become much more frequent than at present. As such, despite no specific requirement in Part B of the Building Regulations (with the exception of means of escape balconies), property developers, designers, specifiers, managers and risk assessors all need to be mindful of the potential fire risks associated with fires on balconies from their incorporation into the building especially from the materials used to meet other Building Regulations requirements (e.g. Part L). References [1] Home and Communities Agency. August 2014. Quality Counts Results of the Affordable Homes Programme Quality Audits 2013/14. Available at: https://www.gov.uk/government/uploads/system/uploads/attachment_data/file/347869/quality_counts _2013-14_final.pdf Last accessed 26 th January 2016. [2] BRE Environmental & Sustainability Standard BES 5053: Issue 2.0 BREEAM Healthcare 2008 Assessors Manual. Available at: http://www.breeam.com/filelibrary/non%20domestic%20manuals/issue%202/breeam_healthcare_ 2008_Issue_2.0.pdf Last accessed 26 th January 2016. [3] HM Government. The Building Regulations 2010. Fire safety. Approved Document B Volume 2 Buildings other than dwellinghouses. London. DCLG, 2006 edition incorporating 2007, 2010 and 2013 amendments, Crown Copyright 2006. [4] http://www.manchestereveningnews.co.uk/news/greater-manchester-news/women-rescued-thirdfloor-balcony-after-8691377 Last accessed 27 th January 2016 [5] http://www.cbsnews.com/news/mom-tosses-baby-from-balcony-during-apartment-fire/ Last accessed 27 th January 2016 [6] HM Government. The Building Regulations 2010. Acknowledgements The research on which this article is based was commissioned by the Department for Communities and Local Government (DCLG) and carried out by BRE. Any views expressed are not necessarily those of DCLG, with whose permission the article is published. Ciara Holland is a Fire Investigator. Martin Shipp is Technical Development Director, Fire Safety. Dr David Crowder is Head of Fire Investigation and Expert Witness Services. BRE staff have carried out fire investigations in support of the Building Regulations (and its precursors) on an ad hoc basis since 1948, and with a dedicated team since 1974. BRE has been wholly owned by the BRE Trust since its privatisation in 1997. BRE s fire investigation team is independent and provides world

class fire investigation services to a wide range of clients, including insurers, legal firms, fire and rescue services, police and government departments.