Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION

Similar documents
First Revision No NFPA [ Section No ]

2021 ICC Group A National Model Codes: Online Voting Guide

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

SUMMARY OF FIRE SPRINKLER REQUIREMENTS FOR ALTERATIONS TO EXISTING BUILDINGS 2015 I-Codes

MVRTA Newburyport Intermodal Parking Facility Newburyport, Massachusetts

Learning Objectives. Copyright Materials NONSTRUCTURAL PROVISIONS FOR MULTI STORY WOOD FRAMED BUILDINGS 2009 WASHINGTON STATE BUILDING CODE (WSBC )

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

FS , 712, 713, 714

Occupancy classification. Ancillary use areas shall be individually classified in accordance with Section

Applying the Building Code During Design

CODE 101 How To Read The California Building Code

VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

Learning Objectives. Copyright Materials MULTI STORY WOOD FRAMED BUILDINGS. Prepared for Wood Products Council. Presented by James E. Churchill, P.E.

INTERNATIONAL CODE INTERPRETATIONS

2015 IBC Exit Systems

G59 12: Final Decision AMPC1

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Advanced Studies of the International Building Code. Presented by Steve Thomas, Colorado Code Consulting, LLC

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

635 BUREAU OF BUILDING CODES AND STANDARDS MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

780 CMR: 9 th Edition Massachusetts State Building Code. Presented to: BSA Codes Committee. DATE: January 20, 2016

The Building Code for Rookies

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

E?? , , , , , , , , , , , , Table ,

Wood Frame. from the Pacific Northwest. British Columbia Building Enclosure Council

WORKSHOP Progressive Multi- Family Design: New Opportunities for Light Frame Mid-Rise Structures

Company Overview. Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code)

General Building Information

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and

A BILL FOR AN ORDINANCE

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Comparison of the life safety elements of the 1997 UBC and the IBC 2000.

The International Building Code (IBC ) is a model code that provides minimum requirements to safeguard the public health, safety and general welfare

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

GENERAL BUILDING HEIGHTS AND AREAS

Following are the NMHC/NAA Recommendations for the ICC Online Consensus Voting which opens on February 8 th, 2016:

E2-09/ (IFC [B] )

Building Codes and Ordinances ARC 227

F , , , , , (New)

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

2018 Group A ICC Code Changes including Tall Wood

International Code INTERPRETATIONS

What is a Won-Door FireGuard Door?

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

2012 IBC Exit Systems

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

Advanced Ventilation for Residential applications FBC Res 2010.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 301

IBC MEANS OF EGRESS. Code Change No: E5-07/08. Original Proposal

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

GENERAL BUILDING HEIGHTS AND AREAS

UBC. (1997 Edition) (p.1-116) 2-hr. shaft required for

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

* RESIDENTIAL PLAN REVIEW *

2018 IBC Update. Based on the 2018 International Building Code, (IBC ) Goal. Objectives. Content

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Department of Public Safety and Corrections Uniform Construction Code Council. Uniform Construction Code (LAC 55:VI.301)

EFFECTIVE USE OF THE IBC/CBC

FIRE AND SMOKE PROTECTION FEATURES

WON-DOOR CORPORATION Won-Door FireGuard Applications

PRESCRIPTIVE COMPLIANCE METHOD

COMMUNITY & DEVELOPMENT SERVICES 840 Northgate Drive, Richland, WA Phone: Fax:

Narrative Summary of Changes to PA UCC

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

The Building Codes A.R.E. Building Design and Construction Exam Prep

GENERAL BUILDING HEIGHTS AND AREAS

INTERIOR FINISHES CHAPTER 8

International Building Code Essentials for Wood Construction

NOTE: For construction other than new commercial or additions (renovations), only those areas below describing the scope of work will be applicable.

City of Tacoma Planning and Development Services

The following chapters or articles of the New Jersey electrical subcode are amended as follows:

Are any structural assemblies fabricated off-site? Yes No

LEAD DESIGN PROFESSIONAL:

CODE ANALYSIS REPORT SECOND FLOOR

Plan Check No. A. ELEVATORS

GENERAL BUILDING HEIGHTS AND AREAS

2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

Code Change No: FS43-06/07

INTERNATIONAL BUILDING CODE MEANS OF EGRESS

RLGA. High-Rise Buildings 2012 International Building Code. By Ronald L. Geren, AIA, CSI, CCS, CCCA, SCIP

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

2012 IBC Inspection of Fire-resistance Rated Walls

SUPPLEMENTAL ACCESSIBILITY NO. 5 PLAN REVIEW CHECKLIST

BUILDING CODES & DESIGN CRITERIA

AN ORDINANCE AMENDING TITLE 10 (BUILDING REGULATIONS)

2015 IBC Special Building Types and Features IBC Special Building Types and Features. Copyright 2016 International Code Council 1

How to Prepare Your LSE Report

5/15/2013. Approved Course Title 2010 Existing Building Code Chapters Florida Building Code, Existing Building. Chapters

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

ROWHOUSE CONSTRUCTION

TOWN OF ROTTERDAM BUILDING DEPARTMENT RESIDENTIAL ACCESSORY BUILDINGS AND STRUCTURE PERMIT APPLICATION Ext 395

Municipal Code of Chicago CHAPTER EXIT REQUIREMENTS

CODE ACTION AMENDMENTS

Plan Submittal Checklist 2015 I-Codes

Transcription:

Chapter 4-16 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION Sections: 4-16-01 PURPOSE 4-16-02 APPLICABLE AREA 4-16-03 CONSTRUCTION AND OCCUPANCY 4-16-04 UPPER BUILDING AREA, HEIGHT, NUMBER OF STORIES AND OTHER REQUIREMENTS 4-16-05 COMMERCIAL KITCHEN GREASE DUCTS AND EXHAUST EQUIPMENT 4-16-06 EARLY ASSISTANCE MEETING 4-16-07 ADDITIONAL INSPECTIONS Section 4-16-01 PURPOSE The purpose of this Chapter is to provide certain minimum standards and requirements to safeguard life or limb, health, property and public welfare by regulating and controlling the design, construction, use, occupancy and location of mixed-use, high density housing located in the downtown core within the Boise City Fire Department s Response Zone. The provisions of this chapter may be used to design and construct five story, Type VA, mixeduse, high density housing over a Type IA podium style building. Buildings designed and constructed under this chapter shall comply with all provisions of this chapter and other codes and ordinances as adopted by the City of Boise. The provisions of this chapter provide an equivalent level of protection to the standards set forth in the International Building Code as adopted by the City of Boise. The building official and fire code official are hereby authorized and directed to enforce the provisions of this ordinance including rendering interpretations to clarify intent and purpose. Any appeals of decisions or determinations made by the code officials may be made to the Board of Appeals created under the International Building Code amendments in the Boise City Building Code of Boise Municipal Code. (Ord-21-2016, Amended, 07/19/2016; 6704, Amended, 02/17/2009; Added, 08/24/2004) Section 4-16-02 APPLICABLE AREA The requirements of this ordinance shall be applicable to new structures, constructed after the effective date of adoption, located in the downtown core within the Boise City Fire Department s Response Zone as illustrated in attachment 4-A. Design and construction of the new structures covered by this ordinance shall also comply with the International Building Code as adopted in Boise City Code, Title 4, Chapter 2. and other applicable codes adopted by Boise City. Where a provision in this chapter is in conflict with Boise City Code, Title 4-02, Title 7, or other adopted codes, the provisions of this chapter shall apply. Page 1 of 7

ATTACHMENT 4-A BOISE CITY FIRE DEPARTMENT S RESPONSE ZONE (Ord-26-15, Repealed and Replaced, 7/5/15; 6704, Amended, 02/17/2009; 6339, Added, 08/24/2004) Section 4-16-03 CONSTRUCTION AND OCCUPANCY A. Single Construction. Single construction buildings complying with this Chapter may be a maximum of five stories of Type VA construction when all of the following conditions are met: 1) The below grade building is constructed of Type IA construction and is separated from the Type VA construction above grade upper building with a horizontal assembly having a minimum 3-hour fire resistance rating. Openings in the horizontal assembly are to be protected in accordance with the provisions in Section 4-16-03, B-1; and 2) The below grade building contains only Group S-2 occupancy, enclosed parking garage, used exclusively for the parking and storage of private motor vehicles, and the above grade upper building contains only Group R-2 occupancy; and Page 2 of 7

Exceptions: a) An exterior assembly area that serves the residential use with a total occupant load less than 300 when located on the floor at grade directly above the 3-hour horizontal assembly of the below grade building. b) The above grade upper building may include B occupancy rooms or B occupancy assembly use areas that are accessory to the residential use of not more than 10% of each floor area provided the total occupant load of the sum of all B occupancy areas on each floor is less than 50. An occupied roof is considered a floor level but not a story. c) Entry lobbies, mechanical rooms, waste and recycling collection, bicycle storage and similar uses incidental to the operation of the building shall be permitted in the below grade building and in the above grade upper building. 3) The maximum above grade upper building shall not be more than five stories nor have an overall building height exceeding 70 feet above the lowest fire apparatus access road as defined in the International Fire Code and this Ordinance; and 4) The structure is located in the Boise City Fire Department s Response Zone as illustrated above in Section 4-16-02. B. Mixed Construction. A structure may be divided into two separate and distinct buildings, upper and lower, for the purpose of determining area limitations, continuity of firewalls, limitation of number of stories and type of construction, when all of the following conditions are met: 1) The lower building is constructed of Type IA construction and is separated from the upper building with a horizontal assembly having a minimum 3-hour fire resistance rating. Openings in the horizontal assembly having a minimum 3-hour fire-resistance rating shall be protected by shaft, stairway, ramp or escalator enclosures extending above and below such openings. The walls of such enclosures shall have not less than 2-hour fire-resistance rating and openings therein shall be protected by opening protection having a minimum 1 ½ -hour fire-protection rating; and Exception: Where the walls of such enclosures extending below the horizontal assembly having a minimum 3-hour fire-resistance rating to the foundation are provided with a fire-resistance rating of not less than 3 hours with openings therein protected as required for walls forming a 3-hour fire barrier, the enclosure walls extending above such floor used as the horizontal assembly having a minimum 3-hour fire-resistance rating shall be permitted to have a 1-hour fireresistance rating provided: a) The upper building is not required to be of Type IA construction; and Page 3 of 7

b) The enclosure walls do not enclose an exit stairway, elevator, ramp or an escalator required to have enclosure walls with not less than 2-hour fireresistance rating; and c) The 1-hour enclosure connects less than four stories and has opening protectives above the horizontal assembly with a fire protection rating of not less than 1-hour. 2) The upper building contains only Group R-2; occupancy and Exceptions: a) An exterior assembly area that serves the residential use with a total occupant load less than 300 when located on the floor directly above the 3-hour horizontal assembly of the lower building. b) The upper building may include B occupancy rooms or B occupancy assembly use areas that are accessory to the residential use of not more than 10% of each floor area provided the total occupant load of the sum of all B occupancy areas on each floor is less than 50. An occupied roof is considered a floor level but not a story. c) Entry lobbies, mechanical rooms, waste and recycling collection, bicycle storage and similar uses incidental to the operation of the building shall be permitted. 3) The lower building contains only occupancies of Group A, B, M, R or S-2 enclosed or open parking garage, used exclusively for the parking and storage of private motor vehicles; and Exception: Entry lobbies, mechanical rooms, waste and recycling collection, bicycle storage and similar uses incidental to the operation of the building shall be permitted. 4) The maximum upper building shall not exceed five stories in height. The finish floor level of the highest occupied level in the upper building shall not exceed 75 feet above the lowest fire apparatus access road as defined in the IFC and this Ordinance; and 5) The structure is located in the Boise City Fire Department s Response Zone as illustrated above in Section 4-16-02. C. Construction Types. Type IA and Type VA construction shall be as specified in the International Building Code as adopted by the City of Boise. Page 4 of 7

(Ord-21-16, Amended, 07/19/2016; 6704. Amended, 02/17/2009; 6339, Amended, 08/24/2004) Section 4-16-04 UPPER BUILDING AREA, HEIGHT, NUMBER OF STORIES AND OTHER REQUIREMENTS Upper building area, height, number of stories and other requirements. The area, height, number of stories and other requirements listed below for the upper building with both single construction and mixed construction methods constructed under this ordinance shall comply with this section. The upper building containing group R-2 Occupancies with accessory uses as described in Boise City Code Section 4-16-03, building area, building height, including allowance of the number of stories to be increased up to a maximum of five stories, shall comply with the following conditions: 1) The tabular area increases for a sprinklered building in IBC Chapter 5 are not permitted; however the tabular allowable area for a nonsprinklered building of Group R-2 occupancy of Type V-A construction may be increased by 25% per floor over the area value listed in the allowable area Table of the IBC. This area increase is calculated separately and is added in addition to any other area increases allowed for frontage increase and single occupancy, multi-story buildings in Chapter 5 of the IBC; and 2) The building shall be sprinklered in accordance with National Fire Protection Association (NFPA) Standard 13; and 3) For mixed construction, the R-2 occupancy area may be increased to 70 feet in height, provided the finished floor of the highest occupied level does not exceed 75 feet and the overall building height does not exceed 95 feet measured from the lowest fire apparatus access road to the building. For single construction the maximum overall building height shall not exceed 70 feet in height above the lowest fire apparatus access road; and 4) The structure shall be located in the Boise City Fire Department s Response Zone as illustrated above in Section 4-16-02; and 5) The exit access travel distance specified in Chapter 10 of the IBC shall be reduced by 40% (0.40) for Group R-2occupancy; and 6) Unless otherwise required to be a higher rating by the code, all exterior walls shall be constructed with a minimum of a 1-hour fire resistive wall assembly rated for exposure to fire from both sides. The exterior wall finish materials per Chapter 14 of the IBC shall be of non-combustible material as described in Chapter 7 of the IBC; and Page 5 of 7

7) Pressurized interior exit stairways shall be provided in accordance with the requirements of the IBC for every required exit stairway. All required exit stairways shall provide roof-access. Exception: The fire code official is authorized to reduce the number of roof-access stairways or pressurized interior exit stairways to not less than two. (Ord-21-16, Amended, 07/19/2016; 6704, Amended, 02/17/2009; 6339, Added, 08/24/2004) Section 4-16-05 COMMERCIAL KITCHEN GREASE DUCTS AND EXHAUST EQUIPMENT Commercial kitchen grease ducts and exhaust equipment shall comply with the requirements of the International Mechanical Code. Ducts that serve Type I hoods and penetrate a floor shall be in a shaft enclosure of not less than two-hour fire resistance rated construction. (Ord-21-16, Amended, 07/19/2016; 6704, Amended, 02/17/2009; 6339, Added, 08/24/2004) Section 4-16-06 EARLY ASSISTANCE MEETING Early Assistance Meeting. As early as practicable in the design process, the applicant shall have an Early Assistance Meeting with Planning and Development Services, Fire Department and other applicable city departments. (Ord-21-16, Amended, 07/19/2016; 6704, Amended, 02/17/2009; 6339, Added, 08/24/2004) Section 4-16-07 ADDITIONAL INSPECTIONS In addition to the required inspections and special inspections specified in the International Building Code and International Fire Code, Planning and Development Services shall require the following additional inspections for buildings constructed pursuant to this chapter: A. Structural Observation. Structural observation shall be provided by the engineer of record. Reports of the structural observation shall be provided to the City Structural Building Inspector periodically during framing. B. Special Inspection. Special inspection shall be provided for fire-resistant penetrations and joints as specified in the IBC and to enhance attention on the key elements of the lateral force resisting systems of the building, including, but not limited to, the following: 1) The grade of structural wood panels used in the shear walls and horizontal diaphragms; and 2) The nail size and pattern of the shear walls and horizontal diaphragms; and 3) The framing, location and length of all shear walls; and Page 6 of 7

4) The hold down installations at all shear wall locations; and 5) The diaphragm chord, drag strut and related details; and 6) The base plate bolting; and 7) The blocking to top plate nailing. The special inspector shall be employed by the owner or the registered design professional in responsible charge acting as the owner's agent, and shall comply with the provisions of Chapter 17 of the International Building Code. C. Continuous Inspection. The permit holder shall coordinate an inspection schedule with the City Structural Building Inspection Division to monitor daily construction activity. D. Fire Alarms and Fire Sprinklers. Fire alarm and fire sprinkler systems shall be inspected, tested and maintained in accordance with NFPA 25 and NFPA 72 on at least a semiannual basis. Inspection reports shall be submitted to the fire code official within 30 days of completion. (Ord-21-16, Amended, 07/19/16; 6704, Amended, 02/17/2009; 6339, Added, 08/24/2004) Page 7 of 7