Concrete Pressure Pipe

Similar documents
North Harris County Regional Water Authority TABLE OF CONTENTS. CONTRACT DOCUMENTS Section No. Title

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section DUCTILE IRON PIPE AND FITTINGS

DUCTILE IRON PIPE AND FITTINGS

Water Transmission Pipelines: An Updated Design Guide Richard D. Mielke, P.E, 1 M.ASCE

AMERON PRESTRESSED CONCRETE CYLINDER PIPE

Strength and Durability for Life GENERAL. Seminars & Lectures

SECTION 1. AMERICAN Standards

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

CONCRETE PRESSURE PIPE

Water Supply Code of Australia

ISO/TS TECHNICAL SPECIFICATION

This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems.

PIPE AND FITTINGS. Submit product information sheet for joint restraint system to be used.

Water Supply Code of Australia

ARTICLE 26 UTILITY LINE INSTALLATION REQUIREMENTS

WATER MAIN EXTENSION DESIGN REQUIREMENTS

SECTION HIGH DENSITY POLYETHYLENE PIPE

DUCTILE IRON PIPE VERSUS BCCP PIPE

DUCTILE IRON PIPE VERSUS BCCP PIPE

Pipelines 2013 ASCE Development History and Characteristics of the Bar-Wrapped Concrete Cylinder Pipe

CVO/169897A OCTOBER 29, CONVEYANCE PIPING GENERAL

UNDERGROUND UTILITY CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

SECTION PIPE INSTALLATION

7. Allowable Fittings.

SUPPLEMENTAL SPECIFICATIONS AND DRAWINGS TO THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION TABLE OF CONTENTS

SECTION WASTEWATER FORCE MAINS

DESIGN OF DUCTILE IRON PIPE ON SUPPORTS

WATER SUPPLY CODE. of Australia. WSA Version 2.3

Material Specification for. Large Diameter Watermains

1.1 SECTION INCLUDES.1 Materials and installation for water mains, hydrants, valves, valve boxes, and valve chambers, including service connections.

CONCRETE PRESSURE PIPE REPAIR GUIDE

SECTION 2100 WATER MAIN

CONSTRUCTION SPECIFICATION FOR PIPELINE INSTALLATION BY TUNNELLING

Pipe & Fittings Water & Sewer. Design Guide

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

F. Provide at least 2 feet of vertical separation between a water line and any utility or stormdrain crossing it.

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

Protecting Existing PCCP Subject to External Transient Loads. 200, Fort Worth, Texas 76109; phone (817) ;

4A General Information A. Concept... 1 B. Conditions... 1

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

Failure Risk of Bar-Wrapped Pipe with Broken Bars and Corroded Cylinder

CONSTRUCTION SPECIFICATION FOR SEWAGE FORCEMAIN INSTALLATION IN OPEN CUT

UBC OKANAGAN UBC Technical Guidelines Section Edition Water Utilities Page 1 of 11

1.02 RELATED WORK: Refer to the following sections for related work:

Chapter 3: Permit Procedures and Requirements


CONSTRUCTION SPECIFICATION FOR TUNNELLING

WATER SUPPLY CODE OF AUSTRALIA. Hunter Water Corporation Version 2

CONSTRUCTION SPECIFICATION FOR PIPE CULVERT INSTALLATION IN OPEN CUT

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY CAST-IN-PLACE. Section CAST-IN-PLACE CONCRETE MANHOLES

SECTION WASTEWATER FORCE MAINS

CONSTRUCTION SPECIFICATION FOR CEMENT MORTAR LINING OF WATERMAINS

Sixth International Water Technology Conference, IWTC 2001, Alexandria, Egypt 143

SPECIFICATIONS - DETAILED PROVISIONS Section Plastic (PVC) Pressure Water Pipe & Fittings C O N T E N T S

CONSTRUCTION PRACTICE MANUAL WATER MAIN INSTALLATION SPECIFICATIONS FOR DEVELOPERS

CITY OF LA MARQUE, TEXAS CHAPTER 3 WATER SYSTEM DESIGN CRITERIA

Innovative Joint Proves Successful in Critical Slipline Project

CONSTRUCTION SPECIFICATION FOR PIPE CULVERT INSTALLATION IN OPEN CUT

SECTION SEWER PIPE

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

HYDRO-AGRICULTURAL DEVELOPMENT PROJECT OF THE IRRIGATION PERIMETER OF DAR KHROFA

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

Table of Contents. Section Pipe and Fittings Section Includes Description of Work Submittals 1. 1.

Draft. Not Yet Approved SECTION 10.1 GENERAL SCOPE DEFINITIONS

SECTION CS-2. TRENCH EXCAVATION CONSTRUCTION STANDARDS

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS SECTION 00005B TABLE OF CONTENTS ***CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS***

SECTION PIPING SPECIALTIES AND ACCESSORIES

Table of Contents. Section Pipe and Fittings Section Includes Description of Work Submittals 1. 1.

Irrigation Rehabilitation Program Design and Construction Standards

SECTION SANITARY UTILITY SEWERAGE PIPING

Pulaski County, Virginia

CHAPTER 8 WATER SUPPLY SYSTEM

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

SECTION 18. AMERICAN General Index

DUCTILE IRON PIPE SUBAQUEOUS CROSSINGS

THE REGIONAL MUNICIPALITY OF PEEL STANDARD SPECIFICATIONS FOR WATERMAINS

Index to Technical Specifications

SECTION GRAVITY IRRIGATION PIPELINES RUBBER GASKETED REINFORCED CONCRETE PIPE (RGRCP)

SECTION PIPE & PIPE FITTINGS PART 1 GENERAL

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

SECTION REINFORCED CONCRETE PRESSURE PIPE AWWA C302 PART 1 GENERAL

VALLECITOS WATER DISTRICT SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE

East Wenatchee Water District Supplemental Provisions to the 2012 WSDOT/APWA Standard Specifications

TUNNEL LINER PLATE INTRODUCTION GENERAL APPLICATIONS CHAPTER 11

Construction Specification for Trenching, Backfilling and Compacting

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

SECTION WATER DISTRIBUTION

MOBILE AREA WATER AND SEWER SYSTEM SECTION 11. Potable Water Utilities Standard Specifications

Table of Contents. Section Pipe and Fittings Section Includes Description of Work Submittals 1. 1.

City of Middletown WATER & SEWER DEPARTMENT 82 Berlin Street Middletown, CT TEL: (860) FAX: (860)

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION DUCTILE IRON PIPE, FITTINGS AND SPECIAL ITEMS

DUCTILE IRON PIPE. The Standard for Quality and Performance

SUPPLEMENTAL SPECIFICATIONS TO STANDARD SPECIFICATIONS FOR WATER MAIN AND SERVICE LINE INSTALLATION NO. 2611

STRUCTURAL MASONRY SPECIAL INSPECTOR. Study Guide

CURRENT NORTH LAS VEGAS ADDENDA

Underground Exhaust System

PART 2 SECTION 9 WATERLINES

Transcription:

Concrete Pressure Pipe AWWA MANUAL M9 Third Edition

Contents List of Figures, vii List of Tables, xi Acknowledgments, xiii Chapter 1 Purpose and Scope............................................... 1 Chapter 2 Description of Concrete Pressure Pipe............................... 3 Prestressed Concrete Cylinder Pipe (ANSI/AWWA C301-Type Pipe), 3 Reinforced Concrete Cylinder Pipe (ANSI/AWWA C300-Type Pipe), 7 Reinforced Concrete Noncylinder Pipe (ANSI/AWWA C302-Type Pipe), 8 Concrete Bar-Wrapped Cylinder Pipe (ANSI/AWWA C303-Type Pipe), 10 Fittings and Special Pipe, 11 Reference, 12 Chapter 3 Hydraulics..................................................... 13 Flow Formulas, 13 Effects of Aging on Carrying Capacity, 20 Head Losses, 20 Determining an Economical Pipe Diameter, 21 Air Entrapment and Release, 25 Blowoff Outlets, 25 References, 25 Chapter 4 Surge Pressure....27 Equations and Variables, 27 Negative Pressures, 30 Causes of Surge Pressure, 30 Control of Water Hammer, 31 References, 32 Chapter 5 External Loads................................................. 33 Major Installation Classifications, 33 Trench Conduits, 33 Embankment Conduits, 37 Positive Projection Installations, 37 Earth Loads on Large Diameter ANSI/AWWA C303 Pipe, 41 iii

Negative Projection Installations, 42 Induced Trench Installations, 44 Jacked or Tunneled Conduits, 47 Determination of Live Load, 48 References, 56 Chapter 6 Bedding and Backfilling.......................................... 57 Introduction, 57 Rigid Pipe, 57 Semirigid Pipe, 59 Unstable Foundations, 60 References, 61 Chapter 7 Design of Reinforced Concrete Pressure Pipe........................ 63 Information Required for Pipe Design, 63 Design Procedure for Rigid Pipe (ANSI/AWWA C300- and C302-Type Pipe), 64 Design Procedure for Semirigid Pipe (ANSI/AWWA C303-Type Pipe), 86 References, 93 Chapter 8 Design of Fittings and Appurtenances....95 Fit tings, 95 Fit tings Design, 98 Specials, 117 References, 119 Chapter 9 Design of Thrust Restraints for Buried Pipe....121 Thrust Forces, 121 Hydrostatic Thrust, 121 Thrust Resistance, 123 Thrust Blocks, 124 Joints With Small Deflections, 126 Tied Joints, 132 Design Examples, 141 Combination Thrust-Restraint System, 167 Other Uses for Restraints, 170 References, 171 Chapter 10 Design of Pipe on Piers...173 Loads, 173 iv

Cylinder Pipe, 173 Location of Piers, 177 Design of Pipe and Supports at Piers, 179 Protection of Exposed Concrete Pipelines, 183 References, 185 Chapter 11 Design of Subaqueous Installations....187 Application, 187 Pipe Design Features, 187 Subaqueous Pipe Details, 190 Installation, 191 Testing, 194 Chapter 12 Design Considerations for Corrosive Environments................. 195 History, 195 Inherent Protective Properties, 195 Special Environmental Conditions, 196 Bonding Pipelines, 199 Monitoring for Pipe Corrosion, 205 Cathodic Protection, 213 References, 214 Chapter 13 Transportation of Pipe......................................... 215 Truck Transportation, 215 Rail Transportation, 215 Barge Transportation, 218 Loading Procedures, 218 Delivery and Unloading, 218 Chapter 14 Installation by Trenching or Tunneling Methods and Equipment..... 221 Trenching General Considerations, 221 Open Trench Construction, 223 Bedding, 226 Pipe Installation General, 227 Laying the Pipe, 228 Backfilling, 230 Tunnel Installations, 232 Jacking Methods, 233 v

Mining Methods, 235 Grouting, 235 References, 238 Chapter 15 Hydrostatic Testing and Disinfection of Mains...239 Hydrostatic Testing, 239 Disinfection of Mains, 241 Reference, 242 Chapter 16 Tapping Concrete Pressure Pipe................................. 243 Threaded Pressure Taps Up to 2 In. (51 mm) in Diameter, 243 Pressure Taps for Flanged Outlets 3 In. (76 mm) and Larger, 245 Tapping Noncylinder Reinforced Concrete Pressure Pipe, 248 Supplemental Data, 248 Chapter 17 Guide Specif ications for the Purchase and Installation of Concrete Pressure Pipe....251 Guide Specifications for Purchasing Concrete Pressure Pipe, 252 Guide Specifications for the Installation of Concrete Pressure Pipe, 254 Index....261 List of AWWA Manuals.................................................... 269 vi

AWWA MANUAL M9 1 Chapter Purpose and Scope The use of concrete pressure pipe for conveying water and other liquids under pressure has dramatically increased in recent years. Its rugged construction and the natural corrosion resistance provided by embedment of the ferrous components in concrete or cement mortar offer the design engineer solutions to a wide range of structural and environmental problems (Figure 1-1). The manufacture of four basic types of concrete pressure pipe are covered by the following American Water Works Association (AWWA) standards: ANSI/AWWA C300 ANSI/AWWA C301 Standard for Reinforced Concrete Pressure Pipe, Steel-Cylinder Type Standard for Prestressed Concrete Pressure Pipe, Steel-Cylinder Type Figure 1-1 A typical installation in rugged terrain 1

2 CONCRETE PRESSURE PIPE ANSI/AWWA C302 ANSI/AWWA C303 Standard for Reinforced Concrete Pressure Pipe, Noncylinder Type Standard for Concrete Pressure Pipe, Bar-Wrapped, Steel-Cylinder Type Preparing pipeline project plans and specifications, however, requires many piperelated decisions that are not covered by the respective AWWA standards. This manual provides supplemental information to assist engineers and designers in achieving optimum field performance of concrete pressure pipelines. Information and guidelines are provided covering hydraulics, surge pressure, external loads, bedding, and backfilling; designing reinforced concrete pressure pipe, fittings and appurtenances, thrust restraints, pipe on piers, and subaqueous installations; design considerations for corrosive environments; transportation of pipe; trench and tunnel installation; and other pertinent subjects. The information in this manual is not intended to supersede, nor should be regarded as superseding, any portion of any AWWA standard. No t e: This manual uses US customary units of measurement. Metric equivalents have been added where deemed appropriate.