Metal and Particulate Emissions from Incinerators Burning Sewage Sludge and Mixed Refuse

Similar documents
On-site Incineration Area Source Category Calculation Methodology Sheet

Questionnaire (Conventional Energy)

IMPACT OF WATER CHEMISTRY ON TEST RESULTS. Peter J. Waznys, P.E. d Carmine J. Desio, P.E. Environmental Laboratories Inc. Mt. Vernon, N.Y.

Material Safety Data Sheet Top Choice Organic Fertilizer. Section 1. Chemical Product and Company Information

Environmental Performance Test of Hazardous Waste Incinerator in Indonesia

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

Application of CFB (Circulating Fluidized Bed) to Sewage Sludge Incinerator

Characterization and Treatment of Incinerator Process Waters

INSTRUMENTATION SYSTEMS FOR MUNICIPAL REFUSE INCINERATORS

Duffin Creek Water Pollution Control Plant Technical Information

COURSE CODE : 4071 COURSE CATEGORY : A PERIODS/ WEEK : 4 PERIODS/ SEMESTER : 56 CREDIT : 4

Georgia Power Plant McDonough-Atkinson NPDES Permit No. GA Ash Pond Dewatering Plan. Revised May 2018

Environmental Issues. GMIC Workshop Columbus, OH Ot20 Oct. 20, C. Philip Ross GICI.

U. S. Army Corps of Engineers Metals Precipitation Checklist

Heavy Metals Removal

Recycling of sewage sludges: pyrolysis.

Fluidized Bed Disposal of Secondary Sludge High in Inorganic Salts

Green Incinerators Brand. Scan & Surf

Collaborative Efforts for Creating a Robust Trace Metals Analytical Procedure for Flue Gas Desulfurization Wastewaters by ICP-MS

CLEANER PRODUCTION GUIDELINES IN SMELTING INDUSTRIESS

INDUSTRIAL SCALE PLANT FOR SEWAGE SLUDGE TREATMENT BY HYDROTHERMAL CARBONIZATION IN JINING/CHINA AND PHOSPHATE RECOVERY BY TERRANOVA ULTRA HTC PROCESS

CeraMem. Ceramic Membrane Technology. Advanced Heavy Metals Removal System WATER TECHNOLOGIES

Cory Riverside Energy. Riverside Resource Recovery Facility

Present Status of Zero-Waste Technology Development and Examples of Public-Private Partnership

INDIRECT THERMAL DESORPTION PLANT

IMMOBILIZATION OF TOXIC HEAVY METALS IN MSW RESIDUE ASH

WASTE INCINERATION PLANTS IN AUSTRIA WITH DATA ON WASTE MANAGEMENT IN VIENNA

Environmental Statement

Field trip to Montenay Dutchess County RRF Poughkeepsie, NY. by Werner Sunk and Georgia Columbus

American Industrial Minerals, LLC 1451 Pier Road Orange, TX Material Safety Data Sheet

PW E-Cell Treatment Report Construction Glacial Till Silty Water

Proposal by Russia to delete hot sub-spot Hot sub-spot name South-West Wastewater Treatment Plant

Industrial Process & Pilot Plant

Cory Environmental. Riverside Resource Recovery Facility

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

Thermal Production of Fertilizer from Organic Waste

Dramatic Improvements at Margajita River at Pueblo Viejo Gold Mine Carlos Tamayo, MBA, PhD, PE Environmental Manager


COAL, OIL SHALE, NATURAL BITUMEN, HEAVY OIL AND PEAT Vol. II -Environmental Impacts of Oil Shale and Pollution Control Technologies - J. Q.

GUIDANCE NOTE ON THE BEST PRACTICABLE MEANS FOR

DeterIllining the EconoIllic Feasibility of Industrial "Waste Fired Boilers

Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill

Development of EAF Dust Recycling and Melting Technology Using the Coal-based FASTMELT Process

GEA Niro Spray Drying Absorption. The easy way to clean the flue gas from waste incinerators. engineering for a better world. GEA Process Engineering

SAFETY DATA SHEET. Iron Silicate (Complex silicates and oxides of iron, silica, calcium, and aluminum) Abrasive air-blasting media

Summary of Session 2. Corrosion in Waste Fired Systems. A. L. Plumley, session chairman Combustion Engineering, Inc.

Frequently Asked Questions for Permitting

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product

Refuse-to-Energy Facility

PELLETIZING AND RECYCLING OF DUST FROM AND TO A LEAD GLASS FURNACE

National Standards of the People's Republic of China

Lessons learnt from Installation (Action B1-B3)

Cory Environmental. Riverside Resource Recovery Facility

Gasification of Municipal Wastewater Primary Sieved Solids in a Rotary Drum Reactor

Hamm MW Pyrolysis Plant. Integrated Pyrolysis into Power Plant Plant capacity 100,000 t/a Pre-processed Waste Materials

Comparison of Sludge Treatment by Gasification vs. Incineration

Relevant BAT phrase: The BAT-associated emission level for diffuse dust emissions is <5 15 g/t hot metal, determined as an annual mean value.

Atmospheric Disperssion

CANADA-WIDE APPROACH FOR THE MANAGEMENT OF WASTEWATER BIOSOLIDS. October 11, 2012 PN 1477

WHERE DO THE PRETREATMENT PERMIT LIMITS COME FROM??? Amy Varinoski City of Mebane

Product Profile. Annexure A. Annexures to Form - I & PFR. MT/ M Consented Ultimate. Crude OBA AND/ OR Standardized OBA liquid/ powder 190 AND/ OR 2600

Fate of elemental contaminants during biomass thermochemical process

Heavy Metal Analysis of Municipal Solid Waste Incinerator Ash and Slag, Palma de Mallorca, 1996.

ADVANCED SOLUTIONS FOR ENVIRONMENTAL ISSUES IN EAF MELTSHOP MICHIO NAKAYAMA *

FOR GOOD RTO OPERATION, KNOW YOUR INPUTS

T-125 EVOLUTION OF THERMAL REMEDIATION. Technical Paper T-125. EVOLUTION OF THERMAL REMEDIATION by Wendell R. Feltman P.E.

Treatment or Process Filtration

INTEGRATED POLLUTION CONTROL SYSTEM FOR SHREVEPORT, LOUISIANA, MUNICIPAL INCINERATOR

Coating Processes. Internal Use Only App# APCD2015 APP

Recovering a Failed Sand Filter Wastewater Treatment System

REACTION TANKS ADVANCED MEMBRANE FILTRATION

CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL

CITY OF FORT MYERS SOUTH ADVANCED WASTEWATER TREATMENT FACILITY

"Waste-to-Energy an essential part of the circular economy "

Effect of high temperature on immobilization of heavy metals in concrete with an addition of galvanic sludge

CETC CANMET Energy Technology Centre Hazardous Waste Combustion in a CFBC

This makes lead-acid battery disposal extremely successful from both environmental and cost perspectives.

Conceptual Facility Plans and Details. Appendix B

The Board of Directors Gerard Kelly Waterford Crystal Limited (Dungarvan) - Application for an IPCL.

Prototype Fly Ash Monitor for Municipal Incinerator Stacks

Annual Environmental Report 2015

ESB Lough Ree Power IPPCL Review - Clarifications

Investigation about Bone Powder as an Alternative Fuel for Circulating Fluidized Bed Combustion

HELIOSOLIDS FLUIDIZED BED INCINERATOR

The Release of Base Metals During Acidic Leaching of Fly Ash

Fluidized Bed Combustion Ashes of Municipal Solid Waste

Springfield, Massachusetts (413)

Flue-Gas Water as a Resource for Carbon-Capturing Power- Plants

CHAPTER 4 A STUDY ON CONTROLLING POLLUTION IN IRON FOUNDRIES LOCATED IN COIMBATORE DISTRICT OF INDIA

Primary Clarifier Odor Control Replacing Nitrates with D.O. Kevin Jacobs, P.E. ECO Oxygen Technologies

Batch waste gasification technology: characteristics and perspectives

Iron and Steel Manufacturing. 40 CFR Part 420

Hot Gas Filters for Control of Emissions to Atmosphere

Thirty Years Later: Evaluation of Heavy Metals Contamination in Bivalves after Successful Load Reduction in Narragansett Bay

Fabric Filter Systems. Providing compliance level control for difficult applications. United McGill products. a McGill AirClean product

First Let s Define some Terms the most important terms used with these concepts are:

Analysis of Metals in Sediments from the Bayou Creek System

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

ANAEROBIC SLUDGE DIGESTION PROCESS. Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit

ENVIRONMENTAL ENGINEERING 343

Transcription:

Metal and Particulate Emissions from Incinerators Burning Sewage Sludge and Mixed Refuse F. l. CROSS, JR. R. J. DRAGO H. E. FRANCIS Roy F. Weston West Chester, Pennsylvania National Air Pollution Control Administration Research Triangle Park, North Carolina State Department of Health Hartford, Connecticut ABSTRACT The experience of many larger municipalities indicates that sludge disposal from sewage-treatment plants can be handled rath r efficiently in incinerators especially designed for this purpose. In addition, a trend seems to be developing to dispose of mixed refuse and sewage sludge in the same unit, in various mixtures. Many of the metals that have caused problems in the past for sanitary engineers responsible for sludge digestion at sewage disposal plants are now adding to air-quality problems in certain communities. The metal and particulate content in the atmospheric emissions from a 300-ton-day incinerator burning mixed refuse and sewage sludge is documented. This paper should be of interest to incinerator designers, air-pollution-control officials, and researchers interested in devising new methods for removing contaminants from stack emissions. INTRODUCTION In the past, municipal incinerators were of interest in air-pollution control mainly because of their emission of smoke, odor, and particul ates. With the more sophisticated techniques now available, attention is being given to the less noticeable but more important constituents in the emissions from these sources and their effect on air quality. The incinerator surveyed for this study is a part of the Waterbury, Connecticut, waste-treatment plant, a system that handles mixed refuse and sewage sludge and serves a population of 110,000 people. The system consists of two lsd-ton/day, circular, batch-fed units. The mixed refuse is burned ev ery day on a 24-h day basis; sewage sludge is burned in one of the units three days a week. The sludge is from the Waterbury sewage-treatment plant, a part of the waste-treatment complex. It is a primary treatment plant, which was designed to treat a flow of 15.2 million gal/day but is now overloaded at 26 million gal/day. Approximately two to three million gal/day of this flow is storm water, and 1000 to 5000 gal/day is septic-tank pumpings disposed of at the plant by scavengers. The sludge from the sewage-treatment-plant clarifiers is vacuum filtered with an Eimco rotary vacuum filter, flashdried, and burned in suspension in the secondary-combustion chamber of one of the incinerator units. The sludge is flash-dried in a Raymond System (Fig. 1). Waterbury is highly industrialized; many metal fabricators and electroplators are located in the area. As a result, large quantities of metals are found in the sewage sludge. For these reasons, the site was selected as appropriate for the purposes of this survey and analysis. TEST FACILITY The Waterbury Plant has two separate lsd-ton/day, circular-type, batch-fed furnaces with individual secon dary-combustion chambers. Effluent from these two chambers feeds into a single expansion and waterspray chamber before entering the 196±-ft stack. Waste 18 9

cooling - con eying incinerator stoker Fig. 1 Flash-Drying System with Mixed-Refuse Incinerator + refuse stock furnace - water spray t 195'-10" to pump station Fig.2 Flow Diagram of Waste-Disposal System 190

heat from one furnace is used to dry sewage sludge by the Raymond process; dried sludge is then returned to the same furnace and burned in suspension (see Fig. 2) The incinerator was installed in 1957. At that time, there were no air-pollution-control devices on the stack. In 1967, the unit was shut down to permit modification by the addition of a wet scrubber to improve the air quality in the region. The installation of the scrubber was completed in 1967, and the system was returned to service in 1968. Visual observations and some cursory laboratory studies indicated that the burning of sewage sludge would alter the pollutant characteristics of emissions. This led to the detailed tests on performance and air-pollution emissions, which are conducted at the facility. The spray chamber has refractory baffles that are continuously wetted and a drain system that leads to a clarifier for fly-ash settling and disposal. Water from the clarifier is returned to the sewage-treatmentplant influent line. Domestic tap water enters the spray chamber through three manifolds ahead of the refractory baffles. The water that is unevaporated goes to the base of the chamber and overflows to the clarifier. The chamber is drained and flushed every 8 h. TESTING PROCEDURE Emissions from the incinerator stack were sampled early in October by F. Rehm of the Wisconsin Chemical and Testing Company. Samples were collected at the 66.5-ft elevation (approximately five stack diameters above the breeching) of the 196± ft-high stack. Three isokinetic samples were collected while the system was burning refuse, and three samples were collected while mixed refuse and dried sludge were being burned. Samples were collected using a null-balance probe. (See Refs. [2] and [3] for a description of the procedu res used.) The stack samples were analyzed for particulates by Wisconsin Chemical and Testing Company (Table 1) and then shipped to the Research Triangle Park, North Carolina to be analyzed for metals by staff members of the Office of Manpower Development, National Air Pollution Control Administration (NAPCA). Fig.3 19 1

Fig" 4 dust bog drum fon Fig.5 Stock Sampling Train 192

Table 1 Dust Loadings Test Run Emission Emission factor Grain/ft 3 lb dust/looo (70 F, 1 atm, dry lb. * flue gas lb dust/ton 50'70 excess air) 50'70 excess air) lb/h refuse Refuse 1 0.320 0.632 74.4 7.44 2 0.268 0.415 60.12 6.45 3 0.268 0.538 73.80 9.43 Mixed 4 0.241 0.499 83.20 7.01 refuse and 5 0.287 0.595 111.00 10.22 sludge 6 0.194 0.397 61.40 4.48 *Not to exceed 0.4 lb dust/looo lb flue gas corrected to 50 percent excess air (State of Connecticut regulation). At the same time that the stack tests were being conducted, water and sludge samples were being collected for metal s analysis by the Connecticut State Department of Health. Identical samples were forwarded also to NAPCA in North Carolina for this purpose. LABORATORY PROCEDURES The stack samples were in two forms: (1) samples in jars from the cyclone collector in the sampling train and (2) glass-fabric filter samples. To put the metals into solution, all samples were leached with an acid solution and digested for 24 h. The acid solution was' a mixture of nitric (HN03) and hydrochloric (HCI) acids in a 2: 1 ratio. The samples were filtered, washed, concentrated, and then made up to a known volume for analysis. All samples were analyzed for metals using atomicabsorption equipment. Most of the analyses were determined on an Instrumentation Laboratory Model 153 instrument (Pb, Cu, Fe, Cr, Zn, and Ni). Cadmium was determined on a Perkin-Elmer Model 403 instrument. Analyses were reported in terms of total weight of metals and then converted to stack concentrations (mg/m3) and emissions (lb/h). Analyses of the water samples were reported in mg/l (Table 2). DISCUSSION As expected, due to the heavy industrialization of the area, analyses showed that there were more metals in the samples collected during the burning of Tabl.e 2 Summary of Water Sample Analysis Source Metals (mg/l) Copper Nickel Zinc Iron Lead Chromium Cadmium Raw water, refuse buming 0.0 0.0 0.1 0.1 0.0 0.0 0.0 Raw water, refuse and sludge burning 0.0 0.0 0.1 0.1 0.0 0.0 0.0 Clarified overflow, refuse burning 0.3 0.0 8.0 0.0 0.5 0.0 0.1 Clarified overflow, refuse and sludge buming 0.0 0.0 0.1 0.0 0.0 0.0 0.0 193

both sludge and refuse than during the burning of refuse alone. This was verified in all of the tests for metals except for lead and cadmium. There was almost no difference in the cadmium emissions when burning either fuel (Table 3). Air-pollutant emissions from both refuse and sludge during burning were 1. 7 times greater than those from burning refuse alone. Emissions of metals while burning refu e ranged from 0.007 lb/h (Cd) to 1.5 lb/h (Pb); when both refuse and sludge were burning, the range was from 0.007 lb/h (Cd) to 2.1'3 lb/h (Zn). It is interesting to note that during the stacksampling tests appreciably more particulates were reported in the bag filters than in the combined cyclone collector and sampling train washdown water. In our analysis, zinc, lead, and cadmium followed this trend, but the quantities of copper, nickel, iron, and chromium were greater in the cyclone samples. This finding would indicate a definite difference in specific gravity, size distribution, and chemical composition of the particles. Since the incinerator charging rate was determined during the tests, emission factors could be calculated in terms of pounds of metals discharged from the stack per ton of fuel charged into the incinerator (see Table 4). These factors should be useful to airpollution-control agency personnel and others conducting emission inventories of municipal incinerator. They provide indicators for metals emissions from a batch-fed incinerator with a wet-baffle scrubber when ei ther mixed refuse alone or refuse and sludge together were burning. The ratio of refuse to sludge in the charges during these tests was approximately equal to 3.5:1. The Table 3 Summary of Metals in Stock Emissions Burning Conditions Run No. Copper Nickel mg/m 3 #/h mg/m 3 #/h Zinc mg/m 3 #/h Iron mg/m 3 #/h Lead Chromium mg/m 3 #/h mg/m 3 #/h Cadmium mg/m 3 #/h Refuse 2 5.7 0.31 0.49 0.03 9.1 0.49 0.71 0.04 27.1 1.54 15.2 0.82 13.4 0.76 15.8 0.86 39.5 2.25 1.16 0.07 21.4 1.16 1.33 0.07 0.15 0.008 0.11 0.006 3 5.8 0.36 0.40 0.02 20.0 1.22 10.2 0.69 18.1 1.11 0.99 0.06 0.13 0.007 Average 6.8 0.38 0.53 0.03 20.8 1.19 13.1 0.77 26.3 1.50 1.16 0.07 0.13 0.007 Refuse 4 10.3 0.75 0.98 0.07 62.7 4.58 15.4 1.13 25.5 1.86 1.93 0.14 0.13 0.009 + Sludge 5 6 12.5 0.82 0.72 0.04 7.9 0.52 0.90 0.06 14.8 0.93 13.6 0.89 11.0 0.72 13.3 0.87 14.1 0.93 1.45 0.09 11.0 0.72 1. 50 0.10 0.09 0.006 0.12 0.007 Average 10.2 0.69 0.87 0.06 30.4 2.13 13.2 0.91 16.8 1.17 1.63 0.11 0.11 0.007 *mg/m 3 1 atm, dry, 70 F, 50 percent excess air. Table 4 Compilation of Emission F oclors Mass Emission Rate (lb/ton of charge) Incinerator Leading Total Conditions Particulates Copper Nickel Zinc Iron Lead Chromium Cadmium Refuse only 7.7 4.2 x 10-2 3.3 x 10-3 1.3_10-1 8.1 _ 10-2 1.5 _10-1 7.7 x 10-3 7.7 _ 10-4 Refuse and sludge 7.23 5.7 x 10-2 4.9 x 10-3 1.8 _ 10-1 7.5-10- 2 9.6 _ 10-2 9.1 x 10-3 5.7 x 10-4 194

burning rate during these tests averaged 85 percent of the rated capacity of the incinerator. The test situation was unusual due to the industrialization of the area and the burning of primary, treated-sewage sludge together with mixed refuse. It is anticipated that additional tests of this nature will be conducted at the Ansonia, Connecticut, municipal incinerator, a system that also burns both mixed refuse and digested sewage sludge. CONCLUSIONS It is increasingly apparent that smoke, odor, and fly ash are not the only important constitutents in air-pollutant emissions from municipal incinerators. In an industrial area in which sludge is burned together with mixed refuse, stack concentrations of metals from 0.13 to 20.8 mg/m 3 may be expected when refuse is burning in a batch-fed operation with a wet-baffled-type scrubber and from O. H to 30.4 mg/m 3 when refuse and sludge together are burning at a 3.5: 1 ratio in the same system. Stack emissions of metals range from 0.007 to 1.22 lb/h when refuse and sewage sludge are burning. Emission factors have been established in terms of pounds of metals emitted per ton of fuel burned and range from 7.7 + 10-4 to 1.5 + 10-1 lb/ton while burning mixed refuse and from 5.7 + 10-4 to 1.8 + 10- lib/ton while refuse and sludge are burning. In the future, the design engineer may develop methods to remove and recover metals from incinerator stack gases, and the ecologist may clarify the deleterious effects of these airborne metals on our environment. ACKNOWLEDGMENTS The authors wish to acknowledge the cooperation of Mr. Walter M. Kunsch, Superintendent of Waste Disposal for Waterbury, Connecticut, for his cooperation during the testing program; to Mr. Charles O. Velzy, Charles R. Velzy Associates, for his patience during the preparation of this article; Mr. John Dedyo, Project Engineer, Charles R. Velzy Associates, for his assistance during the stack tests; and Mr. Fred R. Rehm, P.E., Wisconsin Chemical and Testing Company, for his cooperation in supplying data and collecting stack samples for analysis. REFERENCES [1] Public Health Code Regulations, Section 19 13 G16, Connecticut State Department of Health, April 12,1969. [2] Performance Test Code Committee No. 27, Detennining Dust Concentration in a Gas Stream, Per {onnance Test Code (PTC) 27, ASME, New York, N,Y., 1957. [3] Technical Committee (TA-3), Report TA-3, no. 2, National Air Pollution Control Association, 195