Moment curvature analysis of concrete flexural members confined with CFRP grids

Similar documents
Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

Axial load-bending moment diagrams of GFRP reinforced columns and GFRP encased square columns

Seismic performance of New Steel Concrete Composite Beam-Columns

Influence of Longitudinal FRP Straps on the Behaviour of Circularised and FRP Wrapped Square Hollow RC Concrete Specimens

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

RESILIENT INFRASTRUCTURE June 1 4, 2016

EFFECT OF CONFINEMENT ON THE INTERACTION DIAGRAMS FOR RC SECTIONS WITH CFRP GRIDS AND WRAPS

Experimental tests on RC hollow columns strengthened with FRPs

10.5 ECCENTRICALLY LOADED COLUMNS: AXIAL LOAD AND BENDING.

Analytical prediction of tension force on stirrups in concrete beams longitudinally reinforced with CFRP bars

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Failure Mechanism of Reinforced Concrete Structural Walls with and without confinement

In-plane testing of precast concrete wall panels with grouted sleeve

Effect of Axial load on deformation capacity of RC column

Modeling aspects concerning the axial behavior of RC columns

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

FRP-Confinement of Hollow Concrete Cylinders and Prisms

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Seismic Behavior of Concrete Columns Confined with Steel and Fiber-Reinforced Polymers

Comparisons to Tests on Reinforced Concrete Members

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

FRP Strengthening of RC Flexural Members - Ductility Issues

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

Flexural Analysis and Design of Beams. Chapter 3

Behaviour of FRP wrapped circular reinforced concrete columns

SEISMIC UPGRADING OF EXISTING RC ORDINARY MOMENT RESISTING FRAMES USING FRPS

AN ANALYSIS OF MEMBRANE ACTION IN ONE-WAY CONCRETE MEMBERS EXTERNALLY BONDED WITH FRP

AFRP retrofitting of RC structures in Japan

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

Seismic Performance of Hollow-core Flooring: the Significance of Negative Bending Moments

Regression Model for Predicting Study Parameters of GFRP Strengthened Corrosion Damaged RC Columns P.R.Dhevasenaa, K.Suguna and P.N.

XTRACT: A Tool for Axial Force - Ultimate Curvature Interactions. C.B. Chadwell 1 and R.A. Imbsen 2

Flexural Behavior of Concrete Beam Reinforced with Steel and FRP Re-bars

Strengthening of RC Beams subjected to Combined Torsion and Bending with GFRP Composites

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

A simple computational tool for the verification of concrete walls reinforced by embedded steel profiles.

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

PERFORMANCE OF RC BRIDGE COLUMNS SUBJECTED TO LATERAL LOADING

TESTS ON AN INTERIOR REINFORCED CONCRETE BEAM-COLUMN JOINT. R. Park*, L. Gaerty**, and E.C. Stevenson***

The Use of Sustainable Materials for Quick Repair of Aging Bridges

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

Strengthening of RCC Column Using Glass Fibre Reinforced Polymer (GFRP)

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

FRP-confined concrete-encased cross-shaped steel columns: stub column tests

Effect of prestressed CFRP plate location on behavior of RC beam strengthened with prestressed CFRP plate

CHAPTER 5 FINITE ELEMENT MODELLING

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

A Comparative Study On CFRP Confined RC Capsule Column With Varying Reinforcement Ratio

GFRP retrofitted RC frames with columns subjected to high axial stresses

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

Upgrading ductility of RC beam-column connection with high performance FRP laminates

Design of FRP confinement for square concrete columns

University of Wollongong. Research Online

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Fragility Curves for Seismically Retrofitted Concrete Bridges

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

EXPERIMENTAL STUDY OF THE EFFECT OF REINFORCEMENT STABILITY ON THE CAPACITY OF REINFORCED CONCRETE COLUMNS

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

Inelastic Behavior of Hollow Reinforced Concrete Bridge Columns

LOAD TESTS ON 2-SPAN REINFORCED CONCRETE BEAMS STRENGTHENED WITH FIBRE REINFORCED POLYMER

Experimental study on the effectiveness of CFRP strengthening of shear-deficient reinforced concrete beams under impact loading

2.0 REVIEW OF LITERATURE. In the last few years, the use of fiber-reinforced plastic (FRP) rebars to replace steel

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

FRP Tubes Filled With Concrete and Subjected to Axial Loads, Bending and Combined Loads

Hybrid-steel concrete connections under reversed cyclic loadings

FAILURE MODE CLASSIFICATION OF REINFORCED CONCRETE COLUMNS BY THE ANALYSIS OF THE STRAIN DISTRIBUTION IN THE MAIN REINFORCEMENT

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

BENDING CAPACITY OF COMPOSITE COLD- FORMED STEEL AND CONCRETE OF A STRIP PLATE STRUCTURE

A DESIGN-BASED APPROACH TO ESTIMATE THE MOMENT-CURVATURE RELATIONSHIP OF FIBER REINFORCED ELEMENTS FAILING IN BENDING. Report A0.T0.UM.

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 1, 2011

Study on Grade 75 and 60 Reinforcement in RC design

Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

GFRP HOLLOW-CORE REBARS FOR CONCRETE BEAMS

Pile to Slab Bridge Connections

STEEL JACKETING FOR IMPROVEMENT OF COLUMN STRENGTH AND DUCTILITY

Deflection of GFRP RC Beams

CONCRETE-FILLED SQUARE FRP TUBES UNDER AXIAL COMPRESSION

EFFECT OF SHORT METALLIC FIBERS IN MIXED REINFORCED HRFRC BEAMS : AN EXPERIMENTAL STUDY

Section A A: Slab & Beam Elevation

Comparison of analytical and experimental results of ductility factor in reinforced concrete structures.

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

Load capacity of slender reinforced concrete walls governed by flexural cracking strength of concrete

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

beni-suef university journal of basic and applied sciences 5 (2016) Available online at ScienceDirect

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

CHAPTER 2. Design Formulae for Bending

Using CFRP for Enhancing of Circular Cutout in High Strength RC Deep Beam

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Transcription:

Materials Characterisation V 131 Moment curvature analysis of concrete flexural members confined with CFRP grids A. Michael & P. Christou Department of Civil Engineering, Frederick University, Cyprus Abstract The moment-curvature (M-Φ) diagrams define the maximum capacity of structural elements that are primarily subjected to bending moments and therefore their failure mode is flexural. The moment-curvature diagrams are also used to assess the ductility of structural elements and are therefore very important for the determination of the amount of plastic energy a structural element can absorb. One way of improving the reinforced concrete (RC) members is the confinement of concrete with FRP composites. The work presented in this paper includes the development of moment curvature diagrams for RC members using a fiber model. The RC members were designed as compression controlled members meaning that their failure initiates in the concrete prior to yielding of the steel tension reinforcement. These types of members have limited ductility. The introduction of a specific amount of Carbon Fibre Reinforced Polymer (CFRP) composite grid as confining reinforcement improves the ductility of the RC members by as much as 3%. The results from the fiber model are compared to available results from an experimental program conducted to evaluate the experimental improvement of the ductility of compression controlled members. The experimental and analytical results are a good match indicating that the fiber model is accurate and can be used to develop the moment-curvature diagrams of RC members confined with a CFRP composite grid. Keywords: CFRP grid, concrete confinement, moment curvature, ductility. 1 Introduction Compression controlled steel reinforced members, fail through crushing of concrete and therefore lack the ductility that is associated with yielding of the doi:1.2495/mc11121

132 Materials Characterisation V reinforcement. This is due to the fact that concrete as a material does not behave in a ductile manner. Concrete may exhibit limited ductility (also called pseudo ductility) but this ductility varies depending on the aggregate material and the strength of concrete used. High strength concrete is more brittle than low strength concrete and therefore for high strength concrete the pseudo ductility diminishes. This is similar to concrete members reinforced with Fibre Reinforced Polymer (FRP) composites. FRP reinforcing bars when loaded in tension, exhibit linear stress-strain behaviour up to rupture. There is no yield point and associated plateau to provide a ductile response when used as tensile reinforcement in concrete. Rooney and Taylor [1], Toutanji and Deng [2], and Grace et al. [3] found that the post cracking beam behaviour was linear to failure in concrete beams reinforced with glass FRP rods which shows the lack of a yield plateau and therefore the lack of a ductile response. There have been attempts to improve the ductility of FRP with little or no success. If these members are designed in such a way in order to fail through concrete crushing limited ductility may be exhibited much like in the case of compression controlled members. Therefore, the focus of improving member ductility should be on the concrete for compression controlled members. If the concrete in the compression zone of a flexure dominated member is confined then degradation of the compression zone at capacity is delayed, resulting in a more ductile response. Carbon Fibre Reinforced Polymer (CFRP) composite grids have been used to reinforce concrete decks and beams for both strength and crack control [4 8]. The CFRP composite grid has been used as confinement reinforcement with promising results. In a series of cylinder tests conducted by Michael et al. [9] it was found that the crushing strain of CFRP composite grid confined concrete was more than 2 times higher than the crushing strain of unconfined concrete. The advantage that the CFRP composite grid has over the use of FRP composite wraps that have been used for both confinement of concrete or strengthening of concrete members is the ability of the CFRP composite grid to be embedded in the concrete. The CFRP composite grid has openings that allow concrete to flow through thus can be embedded in the member during construction. This also provides environmental protection to the CFRP composite since the composite is not exposed to the natural elements that can cause environmental degradation to the FRP composite. Moment-curvature diagrams are used to assess the ductility of structural elements and are therefore very important for the determination of the amount of plastic energy a structural element can absorb. The research presented in this paper evaluated the moment-curvature response of compression controlled RC members confined with CFRP composite grid with the use of a fiber model that plots the moment-curvature diagram of such sections. 2 Experimental investigation The unique application of the CFRP composite grid as confining reinforcement was evaluated with the construction of two beams. Beam 1 had no CFRP composite grid tubes and served as the control beam and beam 2 had two CFRP

Materials Characterisation V 133 composite grid tubes placed in the compression zone. Details of the dimensions, amount and location of steel reinforcement and CFRP composite grid tubes are provided in Figures 1 and 2. The CFRP composite grid was formed into a circular tube using a 152 mm diameter plastic pipe and was held in place by a thin rope wrapped around the tube along its length. 5 in (127 mm) 2.75 in (7 mm) 3 in (76 mm) 18 in (457 mm) 6.65 ft (2.3 m) 2.7 ft (.81 m) 6.65 ft (2.3 m) 16 ft (4.87 m) 1 in (25 mm) 1 in (25 mm) #3 (#1) Stirrups 18 in (457 mm) 8 #1 (#32) Bars 2 in (51 mm) 2.75 in (7 mm) 3 in (76 mm) 12 in (35 mm) Figure 1: Details of control beam. 2.75 in (7 mm) 5 in (127 mm) 13 ft (3.96 m) 6.65 ft (2.3 m) 2.7 ft (.81 m) 6.65 ft (2.3 m) 16 ft (4.87 m) 18 in (457 mm).75 in (19 mm) 1 in (25 mm) 1 in (25 mm) 6 in (152 mm) #3 (#1) Stirrups 18 in (457 mm) 8 #1 (#32) Bars 2 in (51 mm) 2.75 in (7 mm) 3 in (76 mm) 12 in (35 mm) Figure 2: Details of grid beam.

134 Materials Characterisation V The beams were tested in a simply supported four-point bending configuration (see Figure 3) in displacement control mode, that is, a constant displacement rate was applied independently of the amount of load. The span length between the two supports was 4.27 m, whereas the total length of the beams was 4.87 m. Actuator 1 Load Cell Spreader Beam D15 D14 D13 D12 D11 D1 D9 D8 D7 D6 D5 D4 D3 D2 D1 1 ft (35 mm) Typ. 18 in (457 mm) South Support North Support 5.5 ft (1.7 m) 3 ft (.91 m) 5.5 ft (1.7 m) LVDT Tilt Meter 6 mm Foil Gauge Figure 3: Test set-up. 3 Moment curvature analysis The moment-curvature (M-Φ) diagrams of the beams were calculated based on experimental data and also based on a theoretical fiber model. The experimental moment-curvature diagrams were calculated based on the displacement profile curves at increasing loads. The displacement profile equation was generated by fitting a 3 rd order polynomial line to the displacement profile curves. The fitted lines were in good agreement with the displacement data (average R 2 =.99). The polynomial displacement profile equation of the beam was used to determine the curvature at specific points along the length of the beam. The second derivative of the polynomial displacement profile equation is the curvature equation. The M-Φ curves of the beams were calculated using a fiber model. The compression zone of the tube beam was separated into two regions with regard to concrete properties. The first region was the concrete cover on top of the CFRP grid tubes and the second region was from the neutral axis to the top of the CFRP grid tubes (see Figure 4). The first region was extended approximately.25 in. (6.5 mm) below the top of the CFRP grid tubes to account for the unconfined concrete at the sides and between the grid tubes. The first region was assigned unconfined concrete properties and the second region confined properties. The concrete area from the neutral axis to the bottom of the grid tubes was unconfined but was treated as confined concrete for simplicity and because

Materials Characterisation V 135 the strains in that area close to the neutral axis were small and therefore the effect on the strength was minor. The unconfined region was divided into one rectangular layer while the confined region was divided into eight rectangular layers. For the control beam, the compression zone was treated as an unconfined concrete region and was divided into eight layers. 1 in. (25 mm).75 in. (19 mm) c - 25 mm (c - 1 in.) Grid Tube N. A. Unconfined concrete Confined concrete Figure 4: Tube beam cross-section fiber model. Some of the assumptions employed in this fiber model include perfect bond between concrete and the reinforcing bars (strain compatibility), plain sections remain plain (linear strain distribution), the area below the neutral axis was considered cracked and was ignored in the force and moment calculation and monotonic loading and deformation of the section. The compressive force in each layer was calculated as the product of the area of the layer and the average stress. The average stress was determined based on the strain in the layer and the stress-strain curves of concrete. The Hognestad parabola was used to calculate the stress-strain curve of unconfined concrete. The modified Hognestad was used to calculate the stress-strain curve of confined concrete [1]. The parameters of the modified Hognestad were determined based on the available data from confined concrete cylinder tests [9]. The tensile force was calculated as the product of the area of steel reinforcement and the steel stress. Steel stress was determined based on the average strain of the two steel layers and by assuming elastic perfectly plastic stress-strain curve. The moment in the cross-section for the applied curvature distribution was determined by summing moments about the neutral axis. The moment curvature diagram was calculated by applying increasingly larger top concrete compressive strains (ε c ) to the cross-section and varying the location of the neutral axis (c) until equilibrium of the axial forces (zero) in the

136 Materials Characterisation V cross-section for the applied strain was achieved. The curvature of the section (Φ = ε c / c) was then calculated based on the concrete compressive strain and the location of the neutral axis. The experimental and fiber model M-Φ diagrams were calculated for both beams. The theoretical and fiber model M-Φ diagrams for the control beam (see Figure 5) were approximately the same. The fiber model M-Φ behaviour of the tube beam was comparable to the experimental behaviour (see Figure 6). The improvement in the ductility of the 5 Curvature x 1 (rads/m) 8 16 24 31 39 678 Moment (kip-ft) 4 3 2 1 Experimental Fiber Model.2.4.6.8 1 Curvature x 1 (rads/in) 542 47 271 136 Moment (kn-m) Figure 5: M-Φ curves for control beam. 5 Curvature x 1 (rads/m) 8 16 24 31 39 678 4 542 Moment (kip-ft) 3 2 1 Expiremental Fiber Model 47 271 136 Moment (kn-m).2.4.6.8 1 Curvature x 1 (rads/in) Figure 6: M-Φ curves for tube beam.

Materials Characterisation V 137 tube beam compared to the control beam, although relatively small, was evident when the experimental M-Φ curves for both beams were compared (see Figure 7). The area under the load-displacement curve represents the amount of energy a structure can absorb before failure. The amount of energy is also a good indicator of ductility. Ductile structures usually can absorb higher amounts of energy compared to non-ductile (brittle) structures. 5 Curvature x 1 (rads/m) 8 16 24 31 39 678 Moment (kip-ft) 4 3 2 1 Control Grid 542 47 271 136 Moment (kn-m).2.4.6.8 1 Curvature x 1 (rads/in) Figure 7: Experimental M-Φ curves. The areas under the experimental moment-curvature curves, of both beams, were calculated and compared. The area under the load-displacement curve of the tube beam was approximately 37% more than that of the control beam. The energy up to peak load was elastic energy while the post peak energy was inelastic. Therefore, the 37% extra energy was primarily inelastic energy which indicated the ability of the tube beam to undergo inelastic deformation compared to the control beam. This represents an improvement in the ductility of the member and is due to the confining effect of the CFRP composite grid. Another way to measure ductility is through ductility factors. Curvature ductility factors are a good way to evaluate the ductility of RC members. The curvature ductility factor (μ Φ ) is defined as the ratio of the ultimate curvature (Φ u ) over the curvature at first yield (Φ y ). The definition of ultimate and yield curvatures is simple when the behaviour is elasto-plastic. Definition of these parameters is more complicated when the behaviour is not elasto-plastic. Usually the behaviour of reinforced concrete is not perfectly elasto-plastic. Therefore, the need for a consistent definition of the ultimate and yield curvatures was realized. Researchers have proposed definitions of ultimate and yield displacement and curvature as well as instructions on how to calculate them.

138 Materials Characterisation V The ultimate curvature has been defined as the curvature at which the lateral load in the descending portion of the load-displacement curve is not less than 8% of the maximum load (P u ) [11 14]. Park and Paulay [15] have argued that the available ultimate deformation (and therefore curvature) is not necessarily the deformation that corresponds to the maximum load capacity. They further argued that when survival without collapse is the criterion, it is too conservative to define ultimate deformation as the deformation corresponding to the maximum load-carrying capacity. It would seem reasonable to recognize at least some of this deformation capacity after the maximum load has been reached and to define the available ultimate deformation as that deformation when the loadcarrying capacity has reduced by some arbitrary amount after maximum load. For example, a 1 or 2% reduction in maximum load-carrying capacity could be tolerated in many cases, but the exact amount would depend on the particular case. The yield displacement (and therefore curvature) can be defined as the displacement at the intersection of the horizontal line representing the ideal lateral capacity, P i, (nominal capacity using the ACI 318 approach and a reduction factor of unity) and the straight line that passes through zero and the point in the load-displacement curve at 75% of the ideal lateral capacity [11 13]. The definitions of yield and ultimate displacements are depicted in Figure 8. P Pu Pi.8 Pu.75 Pi d y or d c y d u u d Figure 8: Ductility factor component definitions. The curvature ductility (μ Φ ) was approximately 1.5 and 2 for the control and tube beam respectively. The schematic for determining Φ u and Φ c for the control beam is shown in Figure 9. The same approach was used in determining the ductility factor for the tube beam. The curvature ductility factor of the tube beam was approximately 33% higher than the curvature ductility factor of the control beam.

Materials Characterisation V 139 5 Curvature x 1 (rads/m) 8 16 24 31 39 678 Moment (kip-ft) 4 3 2 1 M u M i.8 M u.75 M i 542 47 271 136 Moment (kn-m) c.2.4.6.8 1 Curvature x 1 (rads/in) u Figure 9: Curvature ductility factor for control beam. The curvature ductility factor using the fiber model moment-curvature diagram of the control beam was approximately 1.6 which was approximately 4% higher than the experimental. On the other hand, the curvature ductility factor of the tube beam was approximately 2.45 which was an overestimate of approximately 21%. 4 Conclusions In this paper the development of moment-curvature diagrams for compression controlled RC sections confined with CFRP composite grids was presented. These diagrams were compared with diagrams developed from experimental data for the same sections. Based on the results from this comparison the following conclusions can be drawn: 1. The results from the two beams indicate that the CFRP grid provided confinement to the concrete. Confinement was achieved using a series of small diameter CFRP grid tubes rather than wrapping the entire cross-section. 2. The curvature ductility factor of the beam utilizing the CFRP grid tubes was improved by 33% compared to the control beam with no grid tubes. The improvement was significant, considering the small amount of CFRP that was used to confine the compression zone. 3. The energy dissipation of the tube beam was 37% higher compared to the controlled beam due to the effect of concrete confinement. This increase in the energy dissipation of the element also represents an improvement in the ductility due to concrete confinement from the CFRP grid tubes.

14 Materials Characterisation V 4. The results from the fiber model are fairly accurate compared to the experimental data and therefore the model is considered valid. However, there is a divergence after the peak load and further refinement of the model is required. 5. The number of test specimens is limited and therefore the more testing is required. Due to the small number of test specimens the conclusions are drawn with great caution. References [1] Rooney, J., and Taylor, S., 24, Flexural Behaviour of Steel and GFRP Reinforced Concrete Beams, Composites: Part B, Vol. 27, No 3-4, pp. 38-4. [2] Toutanji, H., and Deng Y., 23, Deflection and Crack Width Prediction of Concrete Beams Reinforced with Glass FRP Rods, Construction and Building Materials, Vol. 17, No 1, pp. 69-74. [3] Grace, N. F., Soliman, A. K., Sayed, G. A., and Saleh, K. R., 1998, Behavior and Ductility of Simple and Continuous FRP Reinforced Beams, Journal of Composites for Construction, Vol. 2, No 4, pp. 186-194. [4] Rahman, A. H., Kingsley, C. Y., and Kobayashi, K., 2, Service and Ultimate Load Behavior of Bridge Deck Reinforced with Carbon FRP Grid, Journal of Composites for Construction, Vol. 4, No 1, pp. 16-23. [5] Yost, J. R., Goodspeed, C. H., and Schmeckpeper, E. R., 21, Flexural Performance of Concrete Beams Reinforced with FRP Grids, Journal of Composites for Construction, Vol. 5, No 1, pp. 18-25. [6] Harries, K. A., and Gassman, S. L., 23, Load Tests of Reinforced Concrete Catch Basing Knockout Panels, Department of Civil and Environmental Engineering, University of South Carolina, Report No ST3-1, p. 21. [7] Shao, Y., Johnson, C., and Mirmiran, A., 23, Control of Plastic Shrinkage Cracking of Concrete with TechFab Carbon FRP Grids, Department of Civil, Construction, and Environmental Engineering, North Carolina State University, Report to Tech-Fab Inc, p. [8] Hamilton, H. R, Cook, R. A., and Alfonzo, L., 26, Crack Control in Toppings for Precast Flat Slab Bridge Deck Construction, Department of Civil and Coastal Engineering, University of Florida, Engineering and Industrial Station, Final Report Submitted to FDOT, UF Project No 397, p. 12. [9] Michael, A. P., Hamilton, H. R. III, and Ansley, M. H. (25). Concrete confinement using carbon fiber reinforced polymer grid, American Concrete Institute, SP23-56, Vol. 23, pp. 991-11. [1] Park, R., and Paulay, T., 1975 (a), Chapter 6: Ultimate Deformation and Ductility of Members with Flexure, Reinforced Concrete Structures, John Wiley & Sons, New York, NY, pp. 195-269.

Materials Characterisation V 141 [11] Priestley, M. J. N., and Park, R., 1987, Strength and Ductility of Concrete Bridge Columns under Seismic Loading, ACI Structural Journal, Vol. 84, No 1, pp. 61-76. [12] Zahn, F. A., Park, R., and Priestley, M. J. N., 199, Flexural Strength and Ductility of Circular Hollow Reinforced Concrete Columns without Confinement on Inside Face, ACI Structural Journal, Vol. 87, No 2, pp. 156-166. [13] Sheikh, S. A., and Khoury, S. S., 1993, Confined Concrete Columns with Stubs, ACI Structural Journal, Vol. 9, No 4, pp. 414-431. [14] Yeh, Y. K., Mo, Y. L., and Yang, C. Y., 22, Seismic Performance of Rectangular Hollow Bridge Columns, Journal of Structural Engineering, Vol. 128, No 1, pp. 6-68. [15] Park, R., and Paulay, T., 1975 (b), Chapter 11: Strength and Ductility of Frames, Reinforced Concrete Structures, John Wiley & Sons, New York, NY, pp. 496-69.